23-929-1270 Hibiscus Street-Full Set-5-23-23esig(1)_1WORK AREA (NEW PORCH ROOF) EXIST. SFR REVISION TABLENO.DESCRIPTIONDATEA-0MARTIN ENGINEERING, LLC450 STATE RD. N #106-387 JACKSONVILLE, FL 32259904-472-1459FL CA#32027GENERAL NOTESFRONT PORCH RENOVATION1270 HIBISCUS STREETATLANTIC BEACH, FL 32233SCALE: SHEET NUMBER 5/25/2023 DESIGNED: KCM PROJ.#: 23-929 DRAWN: KCM DATE: NOTED THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON 5/25/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES CONSTRUCTION PLANS FOR FRONT PORCH RENOVATION AT 1270 HIBISCUS STREET ATLANTIC BEACH, FL 32233 GENERAL NOTES: 1.IT IS THE INTENT THAT THIS WORK BE IN CONFORMANCE WITH THE 2020 FLORIDA BUILDING CODE, 7TH ED. RESIDENTIAL AND ALL AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND OCCUPANCY. CONTRACTOR SHALL DO THEIR WORK IN CONFORMANCE WITH ALL APPLICABLE CODES AND REGULATIONS. 2.THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOBSITE PRIOR TO COMMENCING WORK. CONTRACTOR SHALL REPORT ALL DISCREPANCIES THE DRAWINGS AND EXISTING CONDITION TO THE ENGINEER PRIOR TO COMMENCING WORK. 3.THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARE THE PROPERTY OF THE ENGINEER AND MAY NOT BE USED OR REPRODUCED WITHOUT EXPRESSED WRITTEN CONSENT OF THE ENGINEER. 4.ALL DETAILS AND SECTIONS SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 5.CONTRACTOR WILL INCORPORATE ALL NECESSARY LOCAL/STATE/FEDERAL BUILDING, FIRE, AND HANDICAP CODES INTO THE DESIGN AND BASE PROPOSAL FOR A COMPLETE TURN-KEY PROJECT. 6.PROJECT SHALL BE TURNED OVER TO OWNER IN A CLEAN CONDITION WITH ALL TRASH AND DEBRIS REMOVED FROM SITE. ALL WINDOWS AND CLASS CLEAN, ALL FLOORS CLEAN, ALL HORIZONTAL SURFACES DUSTED AND CLEANED, AND ALL PLUMBING AND TOILET FIXTURES CLEAN AND IN GOOD WORKING ORDER. CONTRACTOR SHALL HAUL ALL RUBBISH FROM SITE ON A REGULAR BASIS. DO NOT ALLOW TO ACCUMULATE. 7.CONTRACTOR TO OBTAIN ALL PERMITS, PAY ALL FEES AND TAXES. CONTRACTOR SHALL GUARANTEE ALL MATERIALS & WORKMANSHIP FREE FROM DEFECTS. FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE ION AND SHALL INCLUDE INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 8.DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE THE BEST AVAILABLE DATE OBTAINABLE, BUT ARE NOT GUARANTEED. BEFORE PROCEEDING WITH ANY WORK DEPENDENT ON THE DATA INVOLVED, THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS, OR OTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS PERFORMED BY THE CONTRACTOR OR ANY OF HIS SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, AT RESULTANT EXTRA COST FOR ADJUSTMENT OR WORK AS REQUIRED TO CONFORM TO EXISTING LIMITATIONS, SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBURSEMENT OR COMPENSATION BY THE OWNER. 9.A DESIGNATED LOCATION FOR STORAGE OF CONSTRUCTION MATERIAL AND EQUIPMENT SHALL BE DETERMINED BY THE OWNER AND IDENTIFIED AT THE PRE-CONSTRUCTION MEETING. 10.CONTRACTOR PERSONNEL ARE CONFINED TO AREAS OF BUILDING NECESSARY FOR COMPLETION OF WORK. FREE ACCESS TO ALL PARTS OF THE BUILDING IS NOT ALLOWED. 11.CONTRACTOR IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, UNCRATING, SORTING, SETTING IN PLACE, AND PROTECTING FROM DAMAGE ALL NEW EQUIPMENT FURNISHED BY THE CONTRACTOR. THIS SHALL ALSO APPLY TO ITEMS FURNISHED BY THE OWNER TO THE CONTRACTOR. 12.TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS ESTABLISHED BY FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 13.TERMITE PROTECTION TO BE DONE AFTER ALL EXCAVATION, BACKFILLING AND COMPACTION IS COMPLETE. ANY DISTURBED SOIL TREATMENT MUST BE RETREATED. 14.TREATMENT SHALL BE PROTECTED FROM RAINFALL BY 6 MIL VAPOR BARRIER. IF RAINFALL OCCURS BEFORE BARRIER PLACEMENT, SOIL MUST BE RETREATED. 15.PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE SLAB-ON-GRADE FLOORS SHALL BE NON-CELLULOSE CONTAINING MATERIALS AND RECEIVE AN APPLICATION OF TERMITICIDE IN ANNULAR SPACE BETWEEN SLEEVE AND PIPE. ELECTRICAL NOTES: 1 ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH 2020 FLORIDA BUILDING CODE, 7TH EDITION, RESIDENTIAL AND NFPA 70 2020 NATIONAL ELECTRIC CODE (NEC). 2 ALL SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS SHALL BE IN ACCORDANCE WITH THE SECTION R314 OF 2020 FLORIDA BUILDING CODE, 7TH EDITION. 3 ELECTRICAL CONTRACTOR SHALL PROVIDE GROUND-FAULT CIRCUIT INTERRUPTER PROTECTION IN KITCHENS, BATHROOMS, LAUNDRY, GARAGES, AND OUTDOORS PER 2020 NEC 210.8 (A) 4 ELECTRICAL CONTRACTOR SHALL PROVIDE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION IN LIVING, DINING, HALLWAYS, AND BEDROOMS PER 2020 NEC 210.12 (A) 5 ALL OUTDOOR RECEPTACLES SHALL BE PROTECTED FROM MOISTURE PER 2020 NEC 406.9 6 ALL PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL COMPLY WITH THE MINIMUM REQUIREMENTS PER FBC-ENERGY CONSERVATION R404. 7 ELEVATORS SHALL BE IN ACCORDANCE WITH FBC 2020, 7TH ED, SECTION R321.1 MECHANICAL NOTES: 1.ALL DUCT SIZING SHALL BE IN ACCORDANCE W/ ACCA MANUAL "D". PROVIDE DUCT TESTING IN ACCORDANCE W/ ASHRAE STANDARD 152. 2.DUCT LAYOUT AND ALL OTHER MECHANICAL COMPONENTS ARE SHOWN ON THE APPROVED DUCT LAYOUT PLAN INCLUDED IN THE ENERGY CALCULATION PACKAGE PERFORMED BY OTHERS. 3.ALL DUCTS & AIR HANDLERS NOT LOCATED IN CONDITIONED SPACE SHALL BE TESTED TO BE "SUBSTANTIALLY" LEAK FREE. 4.DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE INSTALLED ACCORDING TO FBC R302.5.2 5.ALL INSULATION SPECIFICATIONS ARE INCLUDED IN THE ENERGY CALCULATION PACKAGE PERFORMED BY OTHERS. IF ANY INSTALLED INSULATION MATERIALS DO NOT MATCH THE ENERGY FORMS, NEW CALCULATIONS SHALL BE PERFORMED OR THE ORIGINAL APPROVED INSULATIONS SHALL BE INSTALLED. 6.ELEVATORS SHALL BE IN ACCORDANCE WITH THE FBC 2020, 7TH ED., SECTION R321.1 PLUMBING NOTES: 1.ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE. 2.ALL EXCAVATION & BACK FILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT, 3.ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO A VOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. 4.VERIFY LOCATION, SIZE, TRAPS, INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES. ANY COST RES UL TING FROM DISCREPANCIES NOT REPORTED AT THIS TIME SHALL BE PAID BY THE CONTRACTOR. 5.WATER PIPING TO BE TYPE "M" OR TYPE "L" COPPER ABOVE OR BELOW GRADE. 6.SOIL, WASTE & VENT PIPING TO BE PVC. #40 DVW. 7.ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS 8.WHERE DISSIMILAR METALS ARE TO BE JOINED, APPROVED INSULATING UNIONS SHALL BE USED. 9.INSULATE HOT WATER LINES WITH 1" THICK SNAP ON INSULATION FIRST 8 FEET FROM WATER HEATER. 10.CONDENSATE LINES TO BE COPPER/PVC DEPENDING ON PROJECT REQUIREMENTS. 11.INSULATE WITH 1/2" THICK ARMAFLEX INSULATION. PLAN SHEETS Label Title A-0 GENERAL NOTES A-1 ELEVATIONS/PLANS A-2 ROOF PLAN/SECTION A-3 FLASHING DETAILS S-1 STRUCTURAL NOTES S-2 FOUNDATION PLAN S-3 FRAMING PLAN S-4 FRAMING DETAILS BUILDING STRUCTURE INFORMATION: EXIST. CONDITIONED...............................................................1497 S,F, EXIST. FRONT PORCH..............................................................84 S.F. EXIST. GARAGE........................................................................495 S.F. TOTAL SPACE.............................................................................2076S.F. (ALL EXISTING AREAS TO REMAIN-NO ADDITIONS) TYPE OF CONSTRUCTION..................................................5B OCCUPANCY:..........................................................................R-3 FIRE SPRINKLERS:................................................................NO MAX HEIGHT OF STRUCTURE............................................<15' KEY PLAN SCALE: N.T.S. 3 : 12 F.F.E. - 1ST FLOOR 0' TOP PLATE 9'-1 1/8"9'-1 1/8"RIDGE 12'-5"3'-3 7/8"5/12 ASPHALT SHINGLES (MTCH. EXIST.) LAP SIDING (MTCH. EXIST) 4x4 POST w/ WRAP 3 : 12 5 : 12 F.F.E. - 1ST FLOOR 0' TOP OF WALL 9'-1 1/8"9'-1 1/8"PORCH ROOF RIDGE 12'-5"3'-3 7/8"EXIST. RIDGE 12'-6 1/8"1 1/8"4x4 POST w/ WRAP ASPHALT SHINGLES (MTCH. EXIST.) 3/12 EXIST. S.F.R. 5 : 12 14'-6" EXIST. SLAB 14'6'-2" (FRAME)3"EXIST. SFR EXIST. GARAGE PORCH EXIST. PLT. 9' MATCH EXIST. PLT. 9'DEMO EXIST. PORCH SHED ROOF & SUPPORTS. EXIST. SLAB TO REMAIN,TYP.4X4 POST w/ WRAP PER OWNERS SPEC.,TYP. 1 A-2 REVISION TABLENO.DESCRIPTIONDATEA-1MARTIN ENGINEERING, LLC450 STATE RD. N #106-387 JACKSONVILLE, FL 32259904-472-1459FL CA#32027ELEVATIONS/PLANSFRONT PORCH RENOVATION1270 HIBISCUS STREETATLANTIC BEACH, FL 32233SCALE: SHEET NUMBER 5/25/2023 DESIGNED: KCM PROJ.#: 23-929 DRAWN: KCM DATE: NOTED THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON 5/25/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES FRONT ELEVATION SCALE: 1/4" = 1'-0" SIDE ELEVATION SCALE: 3/16" = 1'-0" FLOOR PLAN SCALE: 3/16" = 1'-0" 3 : 125 : 125 : 12 ASPHALT SHINGLES (MTCH. EXIST.)MATCH NEW FASCIA w/ EXIST. EXIST. ROOF OVERFRAME AS REQ. PER STRUCT. MAX ROOF PITCH(5/12 APPROX.) TO KEEP NEW RIDGE BELOW EXIST. SFR RIDGE 0'-0" EXIST. SLAB (-12" APPROX. B.F.F.E) ( ) 12 ROOF PITCH PER ELEVATIONS AND ROOF PLAN CONV. FRAMED ROOF SYSTEM. SEE ROOF FRAMING PLAN ROOFING OVER 30# FELT OR APPROVED UNDERLAYMENT ON RATED SHEATHING PER STRUCTURAL PLANS. MTL. DRIP EDGE 6x6 P.T. SUPPORT POST, TYP. EXIST 4" S.O.G. TO REMAIN PORCH POST WRAP & TRIM PER OWNERS SPEC.,TYP. PORCH BEAMS PER FRAMING PLAN, TYP 9'-1" PLATE HT. (MATCH EXIST.) NEW POST FOOTING PER STRUCT. CEILING JOISTS w/ F.C. COVERINGS, TYP. TYPICAL SECTION1 GRADE UPLIFT CONNECTORS PER FRAMING PLAN, TYP. FASCIA BOARD. VENTED VINYL SOFFIT REVISION TABLENO.DESCRIPTIONDATEA-2MARTIN ENGINEERING, LLC450 STATE RD. N #106-387 JACKSONVILLE, FL 32259904-472-1459FL CA#32027ROOF PLAN/SECTIONFRONT PORCH RENOVATION1270 HIBISCUS STREETATLANTIC BEACH, FL 32233SCALE: SHEET NUMBER 5/25/2023 DESIGNED: KCM PROJ.#: 23-929 DRAWN: KCM DATE: NOTED THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON 5/25/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES ROOF PLAN SCALE: 3/16" = 1'-0" ISOMETRIC ROOF N.T.S. VENTILATION CALCULATIONS VENTILATION REQUIRED(NEW PORCH ROOF ONLY): ATTIC SPACE = 84 SQFT 84 / 150 = 0.56 SQFT 0.56 X 144 = 80 SQIN 81 X 0.5(50%) = 41 SQIN NET FREE ROOF VENT REQ'D 81 X 0.5(50%) = 41 SQIN NET FREE SOFFIT VENT REQ'D UPPER ROOF VENT SPECS: 4'-0" VENT PROVIDES 144 SQIN NET FREE SPACE 6'-0" VENT PROVIDES 216 SQIN NET FREE SPACE 8'-0" VENT PROVIDES 288 SQIN NET FREE SPACE RIDGE VENT = 18 SQIN/FT OF NET FREE AREA UPPER ROOF VENT REQUIREMENTS: 40 SQIN / 18 = 3 LIN. FT OR MORE OF RIDGE VENT REQ. SOFFIT VENTS REQUIREMENTS: LIN. FT OF SOFFIT AVAILABLE = 30' AIR FLOW PER LIN. FT. OF VENTED SOFFIT = 5.89 SQIN TOTAL = 177 NET FREE SOFFIT AREA PROVIDED >40 SQIN REQUIRED VENTILATION REQUIREMENTS SHALL BE IN ACCORDANCE W/ SECTION R806.1 OF THE 2020 RESIDENTIAL FLORIDA BUILDING CODE. SOFFIT DETAIL N.T.S. NOTE: ALL SOFFIT MATERIALS AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH FBC R704 AND/OR MANUF. SPECIFICATIONS. 6 " 6 "6 "1 2 " 1 2 " 6 "S I D E L A P 2 " R O O F D E C K U N D E R L A Y M E N T S U C C E E D I N G C O U R S E R A K E D R I P E D G E E N D L A P 6 " E A V E D R I P E D G E UNDER LAYMEN T PLACE SHINGLES 3/8" OVER EAVE & RAKE EDGES TO PROVIDE DRIP EDGE ALONG RAKES, CEMENT SHINGLES TO UNDERLAYMENT & EACH OTHER IN A 4" WIDTH OF ASPHALT PLASTIC ROOF CEMENT NON-CORRODING MTL EAVE DRIP TRIM 6"-7" FROM END OF FIRST SHINGLE TRIM TABS FROM ALL STARTER COURSE SHINGLES STARTER COURSE PLACE SHINGLES CLOSE TOGETHER BUT DO NOT CROWD ALONG RAKES, CEMENT SHINGLES TO UNDERLAYMENT & EACH OTHER IN A 4" WIDTH OF ASPHALT PLASTIC ROOF CEMENT NON-CORRODING MTL EAVE DRIP PLACE SHINGLES 3/8" OVER EAVE & RAKE EDGES TO PROVIDE DRIP EDGE FIRST COURSE 11-1/2" to 12-1/2"11-1/2" to 12-1/2" 1" to 1-1/2"1" to 1-1/2"12"6"SHINGLE NAILING NOTE: DETAILS ARE FOR SLOPES OF 3:12 OR GREATER, FOR SLOPES BELOW 3:12, ALL ROOFING UNDERLAYMENT SHALL BE SELF ADHERING SHEET MEMBRANE APPROVED BY THE SHINGLE MANUFACTURER FOR USE ON LOW SLOPE ROOFING PROJECTS VALLEY SHINGLE INSTALLATION: INSTALL SHINGLES USING WEAVE METHOD 1. EXTEND (1) FULL END SHINGLE MIN. 12" PAST CENTER LINE OF VALLEY. SEE MANUF WRITTEN INSTRUCTION FOR ADDITIONAL INSTALLATION INFORMATION 2. DO NOT NAIL 6" MIN. FROM VALLEY CENTER LINE 24" WIDE METAL VALLEY FLASHING OVER 15# FELT FIBERGLASS SHINGLE ROOFING OVER 15# FELT OVER 7/16" OSB OVER PRE-ENG WD TRUSSES VALLEY FLASHING DETAIL N.T.S. FIBERGLASS SHINGLE ROOFING OVER UNDERLAYMENT INSTALL SHINGLES OVER OFF-RIDGE VENT FLANGE AT HEAD GALVANIZED METAL OFF-RIDGE VENT WITH BAFFLE. SET IN PLASTIC ROOF CEMENT OR SEALANT SCREEN INSTALL OFF-RIDGE VENT FLANGE OVER SHINGLES AT BASE 7/16" OSB OVER PRE-ENG WD TRUSSES OFF-RIDGE VENT FLASHING DETAIL N.T.S. NOTES: 1. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS 2. APPLY ROOFING CEMENT OR SELF-ADHERING FLASHING OVER FLANGE AT HEAD ONLY RESIDENTIAL WOOD FRAME STRUCTURE w/ WOOD SIDING (COOLING CLIMATE) TYPICAL WALL ISOMETRIC TYPICAL WALL WOOD SIDING TYVEK HOMEWRAP 7/16" PLYWOOD SHEATHING 2"x4" WOOD STUDS w/ R13 BATT INSULATION 1/2" GYPSUM BOARD LAP AND TAPE TYVEK AT JOINTS EXTEND TYVEK HEADER WRAPâ AT TOP PLATE OVER SHEATHING 1/2" GYPSUM BOARD (SEAL ALL JOINTS & PENETRATIONS) ROOF/ WALL INTERFACE DETAIL RESIDENTIAL WOOD FRAME STRUCTURE w/ WOOD SIDING (COOLING CLIMATE) ROOFING SHINGLES MEMBRANE TYPE EAVE PROTECTION (48" HIGH MIN.) ROOF SHEATHING c/w H CLIPS 2"x2" WOOD FURRINGS 1/2" PLYWOOD WOOD ROOF RAFTERS BATT INSULATION CEILING JOISTS 1/2" GYPSUM BOARD CUT PLYWOOD TO ALLOW FOR VENTILATION BETWEEN WOOD FURRINGS TAPE TYVEK AT JOINTS TYPICAL WALL WOOD SIDING TYVEK HOMEWRAP 7/16" PLYWOOD SHEATHING 2"x4" WOOD STUDS w/ R-13 BATT INSULATION 1/2" GYPSUM BOARD VENTED SOFFIT FASCIA J-TRIM EAVESTROUGH ROOFINGWEATHER BARRIER WALL SHEATHING SYN WD SIDING OVER APPROVED WEATHER BARRIER LAP WEATHER BARRIER OVER METAL FLASHING AND SECURE WITH STARTER STRIP EXTEND 15# ROOFING FELT UP WALL 7" MIN. 5x5 METAL FLASHING OVER ROOFING FELT (NAIL TO ROOF DECK NOT WALL SHEATHING) CAP SHINGLE - DO NOT NAIL INSTALL WITH ROOF CEMENT SHINGLE ROOFING ROOF CEMENT WALL FLASHING DETAIL - LAP SIDING N.T.S.7" (MIN.)5" (MIN.)1-1/2" (MIN.)STUCCO/CV FINISH ASSEMBLY LAP BARRIER OVER NAILING FLANGE VINYL DRIP/WEEP SCREED 5"x5" METAL FLASHING KICK-OUT FLASHING (SEE DETAIL)2" EXTEND KICK-OUT 2" BEYOND FASCIA FELT UNDERLAYMENT SHINGLE ROOFING MTL DRIP EDGE FASCIA 8" (MIN.)110°5 " (M IN .)5" (MIN.)WATER TIGHT SEAL NOTE: INSTALL KICKOUT FLASHING AT BOTTOM OF ROOF & WALL INTERSECTIONS WALL/KICKOUT FLASHING DETAIL N.T.S.REVISION TABLENO.DESCRIPTIONDATEA-3MARTIN ENGINEERING, LLC450 STATE RD. N #106-387 JACKSONVILLE, FL 32259904-472-1459FL CA#32027FLASHING DETAILSFRONT PORCH RENOVATION1270 HIBISCUS STREETATLANTIC BEACH, FL 32233SCALE: SHEET NUMBER 5/25/2023 DESIGNED: KCM PROJ.#: 23-929 DRAWN: KCM DATE: NOTED THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON 5/25/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES ABBREVIATIONS U.N.O.UNLESS OTHERWISE NOTED EOR SYP SPF O.C. LVL w/ w/o OR "OR" MEANS THAT EITHER OPTION PROVIDED IS SUFFICE FOR THE APPLICATION FBC MAX. MIN. OSB PLYW. PSI PSF PCF TYP SS W.W.M/F SW INT. EXT. CL CLG CMU LG FTG OPT DL LL BM CONT. FFE WITH WITHOUT WELDED WIRE MESH OR FABRIC TYPICAL SHEAR WALL SOUTHERN YELLOW PINE (No. 2 MIN.) SPRUCE-PINE-FIR STAINLESS STEEL POUNDS PER SQUARE INCH POUNDS PER SQUARE FEET PLYWOOD (APA RATED MIN.) POUNDS PER SQUARE FEET ORIENTED STAND BOARD (APA RATED MIN.) OPTIONAL ON CENTER SPACING MINIMUM MAXIMUM LAMINATED VENEER LUMBER (2.0E, 1 3/4" WIDE MIN. U.N.O.) LIVE LOAD LENGTH INTERIOR FOOTING FINISHED FLOOR ELEVATION FLORIDA BUILDING CODE (2017, 6TH EDITION) EXTERIOR ENGINEER OF RECORD DEAD LOAD CONCRETE MASONRY UNIT CEILING CENTER LINE CONTINUOUS BEAM FPA FLORIDA PRODUCT APPROVAL B/T BETWEEN CONN.CONNECTION T/G T&G TOGETHER TONGUE AND GROOVE STAGG.STAGGERED 1 S-1 1 S-1 VIEW DIRECTION LOCATION OF SECTION CUT SHEET No. WHERE SECTION IS LOCATED. DETAIL/SECTION NUMBER SHEET No. WHERE SECTION IS LOCATED. VIEW DIRECTION DETAIL/SECTION NUMBER A 1 S-1 DETAIL/SECTION NUMBER SHEET No. WHERE SECTION IS LOCATED. WALL SECTION ELEVATION DETAIL CALL OUT CUT/ MATCH LINE ELEVATION DATUM XSLAB STEP (INCHES) SYMBOL LEGEND A34 SYP: (22) 8d X 2.5"(13" END LENGTH) SPF: (26) 8d X 2.5" (15" END LENGTH) A35 AC4/6 BC4 TSP SSP SP2 SP1 MSTA24 MSTA18 MSTA12 LTP4 LS90 LS70 HTS20-36 HTS16 H8 H6 H3 H2.5A/T GBC DSP CS20 CS16 CS14 BC6 BC46 LGT4 (4 PLY) LGT3 (3PLY) LGT2 (2PLY) LTS12, 16, 20 MTS 12, 16, 24, 30 SPH4, 6, 8 (9) 10d X 1.5" IN STUDS, (6) 10d X 1.5" IN DBL. PLT (15 TOTAL) (8) 8d X 1.5" NAILS TOTAL (FILL ALL HOLES) (4) 10d X 3" IN STUDS, (3) 10d X 3" IN DBL. PLT/(1) 10d X 3" IN SINGLE PLT. (12) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES) (6) 10d X 3" IN STUDS, (6) 10d X 3" IN PLATES (12 TOTAL) (6) 10d X 3" IN STUDS, (4) 10d X 3" IN PLATES (10 TOTAL) (14) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES) (18) 10d X 2.5" NAILS TOTAL (FILL ALL HOLES) (14) 10d X 2.5" NAILS TOTAL (FILL ALL HOLES) (10) 10d X 2.5" NAILS TOTAL (FILL ALL HOLES) (12) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES) (12) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES) (12) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES) (10) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES) (30) 10d X 3.25" IN STUDS, (16) 1/4" X 3" SDS IN GIRDER (46 TOTAL) (26) 10d X 3.25" IN STUDS, (12) 1/4" X 2.5" SDS IN GIRDER (38 TOTAL) (14) 10d X 3.25" IN STUDS, (16) 10d X 3.25" IN GIRDER (30 TOTAL) (24) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES) (16) 10d X 1.5" NAILS TOTAL(FILL ALL HOLES) (5) 10d X 1.5" IN RAFTER/TRUSS OR STUD, (5) 10d X 1.5" IN PLATES (10 TOTAL) (8) 8d X 2.5" IN STUDS, (8) 8d X 2.5" IN PLATES (16 TOTAL) (4) 8d X 2.5" IN RAFTER/TRUSS, (4) 8d X 2.5" IN PLATES (8 TOTAL) (5) 8d X 2.5" IN RAFTER/TRUSS, (5) 8d X 2.5" IN PLATES (10 TOTAL) (5) 8d X 1.5" IN BRACE, (7) 8d X 2.5" IN TOP PLATES (12 TOTAL) (8) 10d X 3" IN STUDS, (6) 10d X 3" IN DBL. PLT/(2) 10d X 3" IN SINGLE PLT. SYP: (14) 8d X 2.5"(9" END LENGTH) SPF: (16) 8d X 2.5" (9" END LENGTH) SYP: (30) 8d X 2.5"(16" END LENGTH) SPF: (36) 8d X 2.5" (19" END LENGTH) (12) 16d X 3.5" NAILS IN EACH FLANGE (24 TOTAL) (6) 16d X 3.5" IN POST FLANGE, (1) 16d IN BEAM FLANGE (18 TOTAL) (6) 16d X 3.5" NAILS IN EACH FLANGE (12 TOTAL) (14) 16d X 3.5" NAILS IN POST & BEAM (28 TOTAL) (12) 8d X 1.5" NAILS TOTAL (FILL ALL HOLES) FASTENERS SIMPSON CONNECTOR SCHEDULE CLIPS, STRAPS, OR TIES REVISION TABLENO.DESCRIPTIONDATES-1MARTIN ENGINEERING, LLC450 STATE RD. N #106-387 JACKSONVILLE, FL 32259904-472-1459FL CA#32027STRUCTURAL NOTESFRONT PORCH RENOVATION1270 HIBISCUS STREETATLANTIC BEACH, FL 32233SCALE: SHEET NUMBER 5/25/2023 DESIGNED: KCM PROJ.#: 23-929 DRAWN: KCM DATE: NOTED THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON 5/25/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES GENERAL STRUCTURAL NOTES THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOBSITE PRIOR TO COMMENCING WORK. CONTRACTOR SHALL REPORT ALL DISCREPANCIES THE DRAWINGS AND EXISTING CONDITION TO THE ENGINEER PRIOR TO COMMENCING WORK. DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE TYPICAL AND APPLY TO SIMILAR SITUATIONS ELSEWHERE, EXCEPT AS OTHERWISE INDICATED. ADAPT REQUIREMENTS OF DETAILS, SECTIONS, PLANS, AND NOTES AT LOCATIONS WHERE CONDITIONS ARE SIMILAR. DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE THE BEST AVAILABLE DATE OBTAINABLE, BUT ARE NOT GUARANTEED. BEFORE PROCEEDING WITH ANY WORK DEPENDENT ON THE DATA INVOLVED, THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS, OR OTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS PERFORMED BY THE CONTRACTOR OR ANY OF HIS SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, AT RESULTANT EXTRA COST FOR ADJUSTMENT OR WORK AS REQUIRED TO CONFORM TO EXISTING LIMITATIONS, SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBURSEMENT OR COMPENSATION BY THE OWNER. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. CONTRACTOR SHALL LOCATE ALL BURIED UTILITIES PRIOR TO EXCAVATION FOR BUILDING FOUNDATIONS. THE STRUCTURAL ENGINEER SHALL BE NOTIFIED OF POTENTIAL CONFLICTS BETWEEN FOUNDATIONS AND BURIED UTILITIES. CODE REQUIREMENTS: THE BUILDING STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODE 7TH EDITION. OTHER CODES IMPLEMENTED FOR DESIGN INCLUDE: ASCE7-16, ACI 315/318/530, NDS 2018, APA, A.I.S.C., ANSI. FOLLOW ALL APPLICABLE PROVISIONS OF THE FLORIDA BUILDING CODE AND OTHER RELATED CODES FOR ALL PHASES OF CONSTRUCTION. TEMPORARY CONDITIONS: THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS ON INTERACTION OF VARIOUS CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE WORK. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER FINAL CONFIGURATION ONLY. FOUNDATIONS: FOUNDATIONS ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF ON COMPACTED FILL. NO GEOTECHNICAL REPORTS AND/OR IN-SITU SOIL DATA WAS GIVEN TO THE STRUCTURAL ENGINEER PRIOR TO DESIGN. THE BEARING CAPACITY USED FOR DESIGN IS BASED ON ALLOWABLE LOADS FROM THE 2020 FLORIDA BUILDING CODE FOR SANDY SOILS WITH NO CLAY, ORGANIC MATERIAL, OR OTHER DELETERIOUS MATERIALS THAT WOULD AFFECT DESIGN BEARING PRESSURE AND THE PERFORMANCE OF THE FOUNDATIONS. BEFORE CONSTRUCTION COMMENCES, SOIL BEARING CAPACITY SHALL BE VERIFIED BY A SUBSURFACE INVESTIGATION,AS WELL AS FIELD AND LABORATORY TESTS PERFORMED BY A CERTIFIED TESTING LABORATORY, WHOSE REPORT SHALL INCLUDE ANALYSIS AND RECOMMENDATIONS FOR SITE PREPARATION IN ORDER TO BEAR THE FOUNDATION LOADS. ABOVE REPORT SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW BEFORE FOUNDATION CONSTRUCTION BEGINS. CONCRETE: REINFORCED CONCRETE CONSTRUCTION SHALL CONFORM TO THE FBC AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD 28-DAY CYLINDER TESTS PER ASTM C39, AND SHALL BE AS FOLLOWS: f'c ABS W/C MIN CEMENT SLUMP USE 2,500 PSI 0.58 470 LBS 5” +/- 1 ALL SLABS, MONOLITHIC FOOTINGS, SPREAD FOOTINGS 3,000 PSI 0.58 470 LBS 5” +/- 1 TIEBEAMS, COLUMNS, WALLS, ELEVATED SLABS CEMENT SHALL CONFORM TO ASTM C150, TYPE 1. FLY ASH CONFORMING TO ASTM C618, TYPE F OR TYPE C, MAY BE USED TO REPLACE UP TO 20% OF THE CEMENT CONTENT, PROVIDED THAT THE MIX STRENGTH IS SUBSTANTIATED BY TEST DATA. COARSE AGGREGATE SHALL CONFORM TO ASTM C33 WITH A MAXIMUM SIZE OF 3/4". FINE AGGREGATE SHALL BE CLEAN, DURABLE, NATURAL SAND CONFORMING TO ASTM C33. A WATER-REDUCING ADMIXTURE CONFORMING TO ASTM C494, USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, SHALL BE INCORPORATED IN CONCRETE DESIGN MIXES. A HIGH-RANGE WATER-REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE F OR G, MAY BE USED IN CONCRETE MIXES, PROVIDING THAT THE SLUMP DOES NOT EXCEED 8”. SLEEVES, OPENINGS, CONDUIT, AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER BEFORE POURING. NO SLEEVE, OPENING, OR INSERT MAY BE PLACED IN BEAMS, JOISTS, OR COLUMNS UNLESS APPROVED BY THE ENGINEER. CONDUITS EMBEDDED IN SLABS SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN ONE THIRD OF THE THICKNESS OF THE SLAB AND SHALL NOT BE SPACED CLOSER THAN THREE DIAMETERS ON CENTER. PROVIDE 3/4” CHAMFERS ON ALL EXPOSED CONCRETE EDGES, UNLESS NOTED OTHERWISE. WHERE INDICATED OR REQUIRED, SLOPE CONCRETE SLABS TO DRAINS SHOWN ON PLUMBING AND/OR ARCHITECTURAL DRAWINGS. ALL CONCRETE SHALL BE CURED IMMEDIATELY AFTER FINISHING OPERATIONS. WOOD: SAWN LUMBER SHALL BE SOUTHERN PINE #2 WITH THE ALLOWABLE FIBER STRESSES PER THE AWC NATIONAL DESIGN SPECIFICATION. ALL MANUFACTURED LUMBER SHALL BE 2.0E GLUED LAMINATED GEORGIA PACIFIC (OR EQUIV.) AND INSTALLED ACCORDING TO MANUFACTURES RECOMMENDATIONS. ALL HEADERS/BEAMS SHOULD BEAR FULLY ON POSTS AND/ OR MULTI STUD GROUPS UNLESS NOTED OTHERWISE ON PLANS. CONTACT ENGINEER OF RECORD IF HEADER/BEAMS SIZE IS NOT SPECIFIED. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON COMPANY OR USP (OR APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL CONNECTORS SHALL BE GALVANIZED. UNLESS SHOWN OTHERWISE, INSTALL MAXIMUM SIZE AND NUMBER OF FASTENERS SHOWN IN LATEST SIMPSON CATALOG. ALL FRAMING NAILS SHALL BE COMMON NAILS AND SHALL BE OF THE SIZE AND NUMBER INDICATED ON THE DRAWINGS. MINIMUM NAILING REQ. NOT SHOWN SHALL BE AS INDICATED IN TABLE 2304.9.1 OF THE FBC. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED ON THE PLANS OR DETAILS. BOLTS AND LAG SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.1. ALL BOLTS AND LAG SCREWS SHALL BE INSTALLED WITH STANDARD CUT WASHERS. ALL ANCHOR BOLTS AND THREADED ANCHOR RODS SHALL BE IN ACCORDANCE WITH ASTM A307, GRADE A, OR ASTM F1554, GRADE 36. ANCHOR ADHESIVES SHALL BE EITHER SET (EPOXY-TIE) OR AT (ARCYLIC-TIE) BY SIMPSON STRONG-TIE AND INSTALLED ACCORDING TO THE MANUFACTURES INSTRUCTIONS. ALL DRILLED ANCHOR HOLES SHALL BE CLEANED OF ALL DEBRIS AND BRUSHED OUT PRIOR TO INSTALLATION OF ANCHOR ADHESIVE. ALL WOOD MEMBERS EXPOSED TO EXTERIOR CONCRETE, MASONRY, WEATHER, OR EARTH SHALL BE PRESSURE TREATED LUMBER. ALL NAILS DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED. FASTENER REQUIREMENTS IN PRESSURE TREATED LUMBER ARE AS FOLLOWS: ACZA PRESERVATIVE: STANDARD CARBON STEEL. ACQ & MCQ PRESERVATIVE: HOT DIPPED GALVANIZED. SODIUM BORATE: STAINLESS STEEL CONNECTORS & FASTENERS (NOT REQ. FOR SILL PLATES OVER CONCR.& VAPOR BARRIER NOT DIRECTLY EXPOSED TO EARTH OR WEATHER). PREFABRICATED WOOD TRUSSES: SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. CONTRACTOR SHALL NOT BE RELIEVED FROM RESPONSIBILITY FOR ERRORS OR OMISSIONS IN SHOP DRAWINGS OR MIX DESIGNS BY THE ENGINEER'S REVIEW. DESIGN AND MANUFACTURE IN ACCORDANCE WITH TPI "DESIGN SPECIFICATIONS FOR METAL PLATE CONNECTED WOOD TRUSSES", LATEST EDITION. ROOF TRUSS LOADING: SEE TRUSS MANUFACTURES SIGNED AND SEAL TRUSS SHOP DRAWINGS FOR APPLICABLE TRUSS DESIGN LOADS. TRUSS LOADINGS SHALL BE BASED ON THE PROJECTS DESIGN LOADS AND THE MINIMUM LOAD REQUIREMENTS SET FORTH BY ASCE 7-16 AND THE FLORIDA BUILDING CODE, 2020 RESIDENTIAL. ALL TRUSS TO TRUSS CONNECTIONS TO BE DESIGNED BY TRUSS MANUFACTURER AND MADE USING TRUSS HANGERS. TRUSS DIAGRAMS, IF SHOWN, ARE DIAGRAMMATIC ONLY. TRUSS DESIGNER TO DETERMINE AND ESTABLISH EXACT HEIGHT, LENGTH, LOCATION, SPACING, AND WEB MEMBER FOR EACH TRUSS. COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL ITEMS INCLUDING AIR HANDLER LOCATIONS, MECHANICAL ROOMS AND DUCT SPACE AND ROUTING. BUILDER SHALL COORDINATE WITH TRUSS DESIGNER FOR PERMANENT TRUSS BRACING. IF NO BRACING INFORMATION IS PROVIDED, BOTTOM CHORD LATERAL BRACING SHALL BE CONTINUOUS FROM ONE END OF THE BUILDING TO THE OTHER AND SHOULD OVERLAP AT LEAST ONE TRUSS SPACE FOR CONTINUITY. LATERAL BRACING SHALL BE NAILED TO EACH TRUSS WITH A MIN. OF (2) 16d NAILS INCLUDING INTERMEDIATE TRUSSES. SEE TRUSS SHOP DRAWINGS FOR OTHER DETAILS AND SPECIFICATIONS FOR BRACING. REINFORCING STEEL: REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, FOR DEFORMED BAR AND ASTM A185 FOR SMOOTH WELDED WIRE FABRIC (WWF), UNLESS OTHERWISE NOTED. REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE WITH #16 ANNEALED IRON WIRE. ALL DETAILING AND ACCESSORIES SHALL CONFORM TO ACI DETAILING MANUAL SP_66. PROVIDE CHAIRS, SPACERS, BOLSTERS, AND ITEMS IN CONTACT WITH FORMS WITH HOT_DIP GALVANIZED LEGS OR PLASTIC LEGS. ACCURATELY POSITION, SUPPORT, AND SECURE REINFORCEMENT AGAINST DISPLACEMENT BY FORMWORK CONSTRUCTION OR CONCRETE PLACEMENT OPERATIONS. "WET-STICKING" OF REINFORCING IS PROHIBITED. REQUIRED CONCRETE COVER FOR REINFORCING STEEL (UNLESS NOTED OTHERWISE): FOOTINGS 3" BOTTOM AND SIDES, 2" TOP SLABS 3/4" COLUMNS 1-1/2" TO TIES, 2" TOP BEAMS 1-1/2" TO STIRRUPS WALLS 1-1/2” LAP SPLICE CONTINUOUS VERTICAL OR HORIZONTAL BARS IN CONCRETE MEMBERS IN ACCORDANCE WITH ACI 318, LATEST EDITION, FOR CLASS "B" TENSION LAP SPLICES. DO NOT SPLICE CONTINUOUS TOP BARS IN BEAMS AT ENDS OF CLEAR SPANS. DO NOT SPLICE CONTINUOUS BOTTOM BARS IN BEAMS IN CLEAR SPANS BETWEEN SUPPORTS. SHOW ALL SPLICES ON SHOP DRAWINGS. SPLICE LOCATIONS AND METHODS SUBJECT TO APPROVAL OF STRUCTURAL ENGINEER. AT SLAB AND WALL OPENINGS PROVIDE A MINIMUM OF (2) #5 BARS ALL FOUR SIDES AND DIAGONALLY; EXTEND THESE BARS A LAP DISTANCE OR A MINIMUM OF 24” PAST THE OPENING OR HOOK BARS IF DISCONTINUOUS. DOWEL ALL WALLS AND COLUMNS TO FOOTINGS WITH BAR SIZE AND SPACING TO MATCH VERTICAL REINFORCING UNLESS OTHERWISE SHOWN. MASONRY WALLS: MASONRY UNITS SHALL MEET ASTM C90, TYPE 2. ASSEMBLIES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF f'm= 1500. MORTAR SHALL BE TYPE "M" OR "S" AND MEET ASTM C270. GROUT SHALL BE 2000 PSI MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS IN ACCORDANCE WITH ASTM C476. GROUT SHALL CONSIST OF A MIXTURE OF CEMENTITIOUS MATERIALS AND AGGREGATE TO WHICH SUFFICIENT WATER HAS BEEN ADDED TO CAUSE THE MIXTURE TO FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. GROUT SHALL HAVE A MAX. COURSE AGGR. SIZE OF 3/8" & SHALL BE PLACE WITH A SLUMP OF 8 TO 11 INCHES. ALL CELLS CONTAINING VERTICAL BARS, BOND BEAMS, AND ALL CELLS BELOW GRADE SHALL BE FILLED WITH GROUT. MAXIMUM HEIGHT OF GROUT POUR ALLOWED IS 5'-0" UNLESS CLEAN-OUT OPENING IS PROVIDED AT BOTTOM OF CELLS TO BE FILLED. LOCATE CLEAN- OUT OPENINGS IN AREAS NOT EXPOSED TO VIEW. CLEAN OUT OPENINGS SHALL HAVE A MIN, OPENING DIMENSION OF 3 INCHES. UNLESS NOTED OTHERWISE EIGHT INCH MASONRY WALLS SHALL BE PARTIALLY REINFORCED MASONRY WALL CONSTRUCTION WITH #5 AT 48 INCH O.C. IN GROUT FILLED CELLS. ADD (1) #5 REINFORCING BAR EACH SIDE OF OPENINGS EXCEEDING 3 FEET. PROVIDE REINFORCING BARS AT CORNERS, INTERSECTIONS, AND EACH SIDE OF OPENINGS. PROVIDE (2) REINFORCING BARS EACH SIDE OF OPENINGS OVER 4 FEET WIDE, AND AS SHOWN ON THE PLANS. PROVIDE HOOKED DOWELS INTO FOOTINGS AND STRUCTURE ABOVE AND/OR BELOW TO PROVIDE CONTINUITY. PROVIDE 9 GAGE GALVANIZED HORIZONTAL JOINT REINFORCING (DUR-O-WAL OR ENGINEER-APPROVED EQUAL) AT 16” O.C. DO NOT PLACE CONDUITS, PIPES, ETC., IN CELLS WITH VERTICAL REINFORCING. DO NOT RUN CONDUITS, PIPES, ETC., HORIZONTALLY IN CMU WALLS PARALLEL TO LENGTH OF WALL. WHERE MASONRY WALLS ABUT CONCRETE COLUMNS TO BE PLACED PRIOR TO ERECTION OF MASONRY WALLS, PROVIDE DOVETAIL SLOTS BETWEEN COLUMN AND WALLS AND GROUT THE CMU CELL CONTAINING THE DOVETAIL ANCHORS. OTHERWISE, EXTEND CMU HORIZONTAL JOINT REINFORCING THROUGH CONCRETE COLUMN. CONTROL JOINTS SHALL BE PROVIDED IN ALL CONCRETE MASONRY CONSTRUCTION AT LOCATIONS INDICATED ON THE ARCHITECTURAL DRAWINGS. HORIZONTAL WALL REINFORCING SHALL BE STOPPED EACH SIDE OF CONTROL JOINTS. SEE ARCHITECTURAL DRAWINGS FOR SEALANT REQUIREMENTS AT CONTROL JOINTS. USE METAL LATH OR WIRE SCREEN FOR CAVITY CAPS. SHEET METAL, FELT, BUILDING PAPER, OR LIKE MATERIALS ARE PROHIBITED. BRICK VENEER TIES SHALL BE NO. 9 U.S. GAUGE WIRE OR NO. 22 U.S. GAGE x 7/8” CORRUGATED METAL AND SHALL HAVE A HOOK EMBEDDED INTO THE MORTAR JOINT. TIES SHALL BE PLACED WITHIN 12” OF ALL WALL OPENINGS AND SHALL BE SPACED AT NO MORE THAN 18” O.C. HORIZONTALLY AND VERTICALLY ATTACHED THROUGH THE SHEATHING TO THE WALL STUDS. STEEL LINTELS OVER OPENINGS SUPPORTING BRICK VENEER TO BE IN ACCORDANCE WITH THE TABLE BELOW AND R703.8.3. PRECAST CONCRETE LINTELS: UNLESS INDICATED OTHERWISE, ALL LINTELS TO BE "U" TYPE PRECAST CONCRETE UNITS EQUAL TO UNITS MANUFACTURED BY CAST_CRETE CORP. AND PRESTRESSED (AND ADDITIONALLY REINFORCED AS REQUIRED) IN ACCORDANCE WITH CAST CRETE CORP. ''DESIGN MANUAL", LATEST EDITION, FOR THE SPAN AND LOADING CONDITION RELATIVE TO LINTEL LOCATION. LINTEL SIZE IF NOT SHOWN ON THE PLANS SHALL BE 8F8-1B FOR OPENINGS LESS THAN 10 FEET AND 8F16-1B/1T FOR OPENINGS 10 FEET TO 20 FEET. PROVIDE 8" MINIMUM BEARING FOR LINTELS UNLESS NOTED OTHERWISE. STRUCTURAL DESIGN CRITERIA: DESIGN WAS BASED ON THE PRESCRIPTIVE COMPLIANCE METHOD IN ACCORDANCE w/ CHAPTER 5 OF THE 2020 FBC, EXISTING. CLASSIFICATION OF WORK SHALL BE CONSIDERED "ALTERATION LEVEL 2" IN ACCORDANCE w/ CHAPTER 6 OF THE 2020 FBC, EXISTING. STRENGTH AND DEFLECTION CRITERIA IS IN ACCORDANCE THE 2020 FLORIDA BUILDING CODE 7th EDITION. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS REDUCED PER THE 2020 FBC:: LIVE LOAD DEAD LOAD DEFLECTION ROOF:20 PSF 15 PSF L/240 - L/180 CEILINGS: 10 PSF 5PSF L240 - L180 FLOORS:40 PSF 10 PSF L/360 - L/240 DECKS:60 PSF 10 PSF L/360 - L/240 WALLS:PER C&C PER ASCE7-10 L/240 - BRITTLE BELOW TBLE. C3-1 L/180 - FLEXIBLE ULTIMATE WIND SPEED 130 MPH PER ASCE 7-16 NOMINAL WIND SPEED: 101MPH PER FBC R301.2.1.3 EXPOSURE C PER ASCE 7-16 IMPORTANCE FACTOR 1.0 CATEGORY II INTERNAL PRESSURE COEFF +/- 0.55 PARTIALLY ENCLOSED COMPONENTS & CLADDING PRESSURES PER TABLE & CHARTS ON THIS PAGE. WIND-BORNE DEBRIS REGION NO a = 3.0 1.WIND PRESSURES SHOWN ABOVE ARE FOR STRUCTURES WITH A MEAN ROOF HEIGHT OF 30 FEET OR LESS WITH A ROOF PITCH B/T 2/12 AND 12/12 (VERT./HORIZ.). IF THE STRUCTURE IS OUTSIDE THESE PARAMETER PLEASE CONTACT THE ENGINEER. 2.THE EFFECTIVE AREA IS EQUAL TO THE LENGTH * WIDTH OF THE PROPOSED OPENING OR SPAN. THE WIDTH SHALL BE PERMITTED TO BE NOT LESS THAN 1/3 OF THE SPAN LENGTH. THE EFFECTIVE AREA FOR FASTENERS SHALL NOT BE GREATER THAN THE TRIBUTARY AREA B/T FASTENERS. 3.ALL WIND PRESSURE VALUES IN POUNDS PER SQ. FT(PSF) & ARE CONSIDERED NOMINAL VALUES(ASD). WIND ZONE CHARTS WIND PRESSURES ON WALLS & ROOFS TYP. POST SPREAD FOOTING 1 6X6 POST w/ ABU66 HOLDOWN, INSTALL PER TYP. ANCHOR DETAILS ON 3/ S-4, TYP. POST FTG. w/ (2) No. 5 BARS E.W. MIN. 2,500PSI CONC. EXIST. S.O.G. TO REMAIN 24"12"EXIST. GRADE 24" SQ. FTG. w/ (2) No. 5 BARS CENTERED UNDER POSTS EXIST. PORCH S.O.G. TO REMAIN EXIST. STEMWALL w/ SLAB 1 S-2 1 S-2 REVISION TABLENO.DESCRIPTIONDATES-2MARTIN ENGINEERING, LLC450 STATE RD. N #106-387 JACKSONVILLE, FL 32259904-472-1459FL CA#32027FOUNDATION PLANFRONT PORCH RENOVATION1270 HIBISCUS STREETATLANTIC BEACH, FL 32233SCALE: SHEET NUMBER 5/25/2023 DESIGNED: KCM PROJ.#: 23-929 DRAWN: KCM DATE: NOTED THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON 5/25/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES NOTE TO CONTRACTOR:THE PLAN SHOWN ON THIS SHEET IS FOR STRUCTURAL FOUNDATION REQUIREMENTS AND LOCATIONS ONLY. REFER TO THE ARCHITECTURAL PLANS FOR SLAB AND FOUNDATION DIMENSIONS. FOUNDATION PLAN SCALE: 1/4" = 1'-0" (2) 2x10 No. 2 SYP PORCH BEAMS, TYP. 4x4 No. 2 SYP PORCH POSTS, TYP. AA 1 S-4 1 S-4 AA EXIST. W.D. FRAMED SFR ROOF/CEILING FRAMING 2X6 ROOF RAFTERS at 24" O.C. 2x6 COLLAR TIES at 24" O.C. 2x8 CEILING JOISTS at 24" O.C. SLEEPERS & FASTENING PER NOTES EXIST. TRUSS ROOF AT 24" O.C. (V.I.F.) OVERFRAMING PER NOTES, TYP. 2x8 RIDGE BOARD 2x4 OUTLOOKERS AT 24" O.C. w/ (1) H2.5A 2 S-4 2 S-4 ROOF SHEATHINGPER LEGEND4 S-4 4 S-4 REVISION TABLENO.DESCRIPTIONDATES-3MARTIN ENGINEERING, LLC450 STATE RD. N #106-387 JACKSONVILLE, FL 32259904-472-1459FL CA#32027FRAMING PLANFRONT PORCH RENOVATION1270 HIBISCUS STREETATLANTIC BEACH, FL 32233SCALE: SHEET NUMBER 5/25/2023 DESIGNED: KCM PROJ.#: 23-929 DRAWN: KCM DATE: NOTED THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON 5/25/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES 1.ALL WOOD STRUCTURAL SHEATHING SHALL BE APA RATED, EXPOSURE 1. 2.STRUCTURAL WOOD PANELS NOMINAL THICKNESS & SPAN RATINGS SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: 7/16" = .437" THICKNESS - 24/16 SPAN RATING 15/32" = .469" THICKNESS - 32/16 SPAN RATING 19/32" = .594" THICKNESS - 40/20 SPAN RATING 23/32" = .719" THICKNESS - 48/24 SPAN RATING 3. ALL ROOF SHEATHING SHALL BE INSTALLED WITH THE LONG DIMENSION PERPENDICULAR TO THE ROOF SUPPORTS. 4. SHEATHING/SUBSTRATES & FASTENINGS FOR EACH ROOFING TYPE SHALL BE IN ACCORDANCE w/ THE FLORIDA PRODUCT APPROVAL. 5. FASTENERS FOR ROOF SHEATHING GREATER THAN 15/32" SHALL BE 8d COMMON(.131x2 1/2") RING SHANK NAILS U.N.O. 6. 2x BLOCKING FOR EDGE NAILING SHALL BE INSTALLED IF NOTED ON THE PLANS. ROOF FLOOR 15/32" OSB/PLY.6" O.C.4" O.C. FIELD & EDGES, 4' FROM ROOF EDGE/END WALL TYPE SHEATHING EDGES GABLE ENDS SHEATHING FASTENING SHEATHING LEGEND FASTENERS 23/32" OSB/PLY. 3/8" OSB/PLY. PORCH CLG. WALLS PER SHEAR WALL LEGEND. 8d RING SHANK 10d COM. (GLUED & NAILED) 8d COM./BOX FIELD 6" O.C. 3" O.C. 6" O.C. 6" O.C. 6" O.C. 7/16" (MIN.) OSB/PLY. 8d COM./BOX (U.N.O.) FRAMING PLAN SCALE: 1/4" = 1'-0" EXISTING BEARING WALLS PORCH BEAMS AND OTHERS POST/COLUMN ROOF RAFTERS CEILING JOISTS/COLLAR TIES STRUCTURAL LEGEND. CONVENTIONAL ROOF FRAMING/OVER FRAMING NOTES: 1 ALL ROOF FRAMING MATERIALS SHALL BE No. 2 SOUTHERN YELLOW PINE (SYP) AT 24" O.C. U.N.O. 2 ALL ROOF RAFTERS AND COLLAR TIES TO BE A MIN. OF 2x6 No. 2 SYP. RIDGE BOARDS TO BE MIN. OF 2x8 No. 2 SYP. 3 ALL SLEEPERS TO BE A MIN. OF 2x8 No. 2 SYP FASTENED TO EACH TRUSS/RAFTER BELOW w/ (2) #10x3.5 DECK SCREWS INTO EXIST. TRUSSES OR ROOF FRAMING. (MAX 24"O.C.) 4 FASTEN ROOF RAFTERS TO RIDGE BOARDS AND "SLEEPERS" W/ SIMPSON A35 CLIPS, U.N.O. 5 FASTEN COLLAR TIES TO ROOF RAFTERS W/ (6) 10d NAILS AT EACH END. 6 COLLAR TIES SHALL BE FASTENED IN THE UPPER 1/3 OF OVERALL ROOF RAFTER HEIGHT. PLACE 2-PLY STUD GROUP IN EXIST. WALL UNDER NEW PORCH BEAM. NOTCH TOP OF BEAM AT EXIST TOP PLT. (3" MAX).FASTEN STUDS T/G/ w/ 8d NAILS AT 6" O.C. STAGG. FASTEN BEAM TO STUD GROUP w/ (1) HTS16 STRAP. FASTEN STUD GROUP TO EXIST. FTG. w/ (1) DTT2Z H.D. INSTALL PER TYP. DETAIL AA ABU44Z (ABU66, ABU88 similar) ABU66Z POST BASE. FILL ALL HOLES w/ 16d NAILS. ABU44:. 1/2" ANCHOR BOLT OR THREADED ROD. ABU66: 5/8" ANCHOR BOLT OR THREADED ROD. ABU88: (2) 5/8" ANCHOR BOLTS OR THREADED ROD. PRESSURE TREATED PORCH POST. SEE PLAN FOR SIZE & LOCATION FILL ALL HOLES w/ 1/4" x 2.25" SIMSPON SDS SCREWS, TYP. FASTEN ANCHOR TO FTG. PER TYP. ANCHOR DETAIL BELOW 2x PT SOLE PLATE, TYP DTT2Z HOLDOWN MIN. 2-PLY STUD GROUP OR 3"x3.5" MEMBER SIZE MINIMUM 1/2" THREADED ROD w/ NUT OR HD TITEN ANCHOR LINEPLATEINSTALL COLLAR TIES IN UPPER 1/3 OF ROOF HT.TYPICAL ANCHOR DETAILS 3 CONV. FRAMED ROOF SYSTEM. SEE ROOF FRAMING PLAN APA. RATED SHEATHING PER SHEATHING LEGEND,TYP. 4X4 P.T. SUPPORT POST, TYP. POST TO FTG. w/ ABU44 HOLDOWN. INSTALL PER TYP. ANCHOR DETAILS. EXIST. S.O.G. TO REMAIN, TYP. FASTEN EACH BEAM TO POSTS w/ (1) MSTA24 STRAPS OR (1) HTS16 STRAPS,TYP. PATIO BEAMS PER FRAMING PLAN. FASTEN T/G. w/ 10d's NAILS AT 8" O.C. STAGG EACH SIDE, TYP. NEW POST FOOTING PER FOUNDATION PLAN & DETAILS, TYP. CEILING JOISTS TO RAFTERS PER TYP. ROOF FRAMING DETAIL, TYP. TYPICAL POST SECTION1 GRADE SDWC15600 OR H2.5A UPLIFT CONNECTORS AT EACH RAFTER TO BEAM CONNECTION, TYP. FASCIA TO RAFTERS/TRUSSES w/ (2) 8d NAILS,TYP. FASTEN COLLAR TIES TO RAFTERS w/ (6) 10d NAILS,TYP. RIDGE BOARD PER ROOF FRAMING PLAN,TYP. APA RATED SHEATHING PER LEGEND ON FRAMING PLAN, TYP. TYPICAL ROOF FRAMING SECTION2 CEILING JOISTS TO RAFTERS w/ (8) 10d NAILS, TYP. COLLAR TIES CEILING JOISTS ROOF RAFTERS TO RIDGE BOARD w/ A35 CLIPS, TYP. R O O F R A F T E R S ANCHOR BOLTS TO HAVE MIN 7" EMBED. 2X4 No. 2 OUTLOOKERS AT 24" O.C. H2.5A OR SDWC15600 SHEATHING NAILED AT 4" O.C. OVER O.L. BEAMS GABLE END BALLOON FRAMING 3-8d TOE-NAILS. TYP. 2x6 BLK. w/ (3) 10d TOE- NAILS TO RAFTERS 2x4 SPF GABLE ENDWALL w/ 7/16" OSB SHEATHING w/ WEATHER BARRIER. FASTEN w/ 8d NAILS AT 6" O.C. BRACE TO BEAM w. (4) 10d TOE NAILS, TYP. CLG. JOISTS RAFTERS 2x4 GABLE END BRACE AT 48" O.C. RIDGE BOARD BRACE TO BLK. w/ (4) 10d FACE NAILS. TYP. TYP. GABLE END FRAMING4 REVISION TABLENO.DESCRIPTIONDATES-4MARTIN ENGINEERING, LLC450 STATE RD. N #106-387 JACKSONVILLE, FL 32259904-472-1459FL CA#32027FRAMING DETAILSFRONT PORCH RENOVATION1270 HIBISCUS STREETATLANTIC BEACH, FL 32233SCALE: SHEET NUMBER 5/25/2023 DESIGNED: KCM PROJ.#: 23-929 DRAWN: KCM DATE: NOTED THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON 5/25/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES