Loading...
1600 Selva Marina Dr MECH23-0015 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: ATLANTIC BEACH COUNTRY CLUB INC 1600 SELVA MARINA DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: TRIMARK STRATEGIC LLC 5843 BERRY RD TAMPA FL 33634 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172000 0010 SELVA MARINA UNIT 05 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1600 SELVA MARINA DR MECHANICAL COMMERCIAL SEPARATE PLANS HOOD PETE'S TURN - GREASE HOOD ONLY $3200.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT COMMERCIAL HOOD INSTALLATION 455-0000-322-1000 0 $30.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $89.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 11/30/2023 PERMIT NUMBER MECH23-0015 ISSUED: 11/30/2023 EXPIRES: 5/28/2024 MECHANICAL COMMERCIAL SEPARATE PLANS PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD 2 of 2Issued Date: 11/30/2023 PERMIT NUMBER MECH23-0015 ISSUED: 11/30/2023 EXPIRES: 5/28/2024 MECHANICAL COMMERCIAL SEPARATE PLANS PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD MECH23-0015 UP F F FFMOD3 4-A6.0 3 4-A6.0 1 4-A6.0 1 4-A6.0 1 4-A5.1 1 4-A5.0 2 4-A5.0 2 4-A5.1 4 4-A6.0 4 4-A6.0 DINING 400 KITCHEN 401 PLATFORM LIFT 407 FIRE RISER 408 WATER HEATER CLOSET 405 MEN'S 404 VESTIBULE 403 WOMEN'S 402 STORAGE 1 412 TRASH ENCLOSURE 410 COOLER 406 400-1 405 404 403-1 402 403-2 105 106 DUMB WAITER 410 08.01 06.01 06.02 11.02 11.03 21 3 A B 40' - 0"11' - 10 1/2"32' - 0"402 06.03 1' - 0" DS DS DS DS DSDS DS MECHANICAL 409 06.03 4' - 7 1/2" 14.01 409 406 401 410412 C01 C01C01 A31 A31 A34 A02 03.01 06.06 9' - 10"5' - 5 1/2" 13' - 6"2' - 11 1/2"8' - 5 1/2"16' - 0"7' - 2"6' - 5"5' - 3"11' - 2 1/2"10' - 0"8' - 5 1/2"9' - 9 1/2" 16' - 6" 21' - 4 1/2" 7' - 0" 12' - 6"13' - 8"8' - 5 1/2"2' - 11"2' - 4"1' - 6" 06.04 03.02 07.01 11.04 12.01 11.06 06.05 05.01 05.01 07.01 05.02 14.02 26.01 07.02 PARKING LOTCART PATH10' - 2"0-A0.98 2 26.01 1 0-A0.97 A02 A02 A02 A01 08.02 08.02 400-2 08.03 02.01 08.04 3' - 9 1/2"10.02 10.01 07.03 407-1 STORAGE 2 413 A31 413-1 2' - 0"8' - 8 1/2"06.07 06.07 A31 1 408 1 1 1 1 1 30" x 48" CLEAR FLOOR SPACE(2020 FBC ACCESSIBILITY) 1 LEGEND EXISTING WALL DEMO WALL NEW WALL NEW WORK KEYNOTE 101 W10 06.01 WALL TAG. SEE 0-A0.50 THRU 0-A0.53 DOOR TAG. SEE 0-A0.20 THRU 0-A0.23 WINDOW TAG. SEE 0-A0.20 THRU 0-A0.23 MATCHLINE A1 EXHAUST STEP LIGHT DRAWN BY: PROJECT NO.: SCALE: REVISION NO.DATE DESCRIPTION THE INFORMATION SHOWN ON THESE DRAWINGS IS OWNED BY AND IS THE PROPERTY OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. NO PART THEREOF SHALL BE COPIED, ADAPTED, OR DISTRIBUTED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SHEPPHIRD ASSOCIATES, ARCHITECTS + ENGINEERS. COPYRIGHT © 2023 26560 AGOURA ROAD, SUITE 106 CALABASAS, CA 91302 310.670.9144 A S S O C I A T E S ARCHITECTS + ENGINEERS S H E P P H I R D will.s@shep-ae.com 1 12-02-22 SD PRICING 2 2-10-23 DD PRICING 3 3-30-23 90% CD 4 5-23-23 PERMIT SET As indicated 7/16/2023 12:20:16 PM Autodesk Docs://2022-352 ABCC/R22_ABCC_BLDG4_ARCH.rvt 4-A2.0PETE'S TURN NEW WORK PLAN -LEVEL 12022-352 WRS / MW / MJ / NY Atlantic Beach Country Club 1600 Selva Marina Drive Atlantic Beach, FL 32233 Phase 1 Construction Documents 0 1 2 4 8FEET 1/4" = 1'-0" SCALE:1 PHASE 1 - PETE'S TURN NEW WORK PLAN - LEVEL 1 KEYNOTES NO.DESCRIPTION DETAIL █ DIVISION 02 - EXISTING CONDITIONS 02.01 (E) TO REMAIN █ DIVISION 03 - CONCRETE 03.01 SEALED CONCRETE 1/4" SLOPE TO DRAIN 03.02 4" CONCRETE PAD ON GRADE, SEE MECHANICAL █ DIVISION 05 - METAL 05.01 HANDRAIL 05.02 COORDINATE MECH. LOUVER W/ ARCHITECTURAL LOUVERS TO ATTAIN CONSISTENT APPEARANCE █ DIVISION 06 - WOOD, PLASTICS & COMPOSITES 06.01 UPPER MILLWORK CABINET, SEE ID 06.02 LOWER MILLWORK CABINTETS, SEE ID. 06.03 WOOD FRAMED STAIR WITH SOLID PLASTIC DECKING TREADS, RISERS & LANDINGS 0-A0.74 06.04 PAINTED WOOD BOARD FENCE 06.05 STAIR LANDING AT SECOND LEVEL 06.06 FRP WALL FINISH INSIDE TRASH ENCLOSURE 06.07 <varies> █ DIVISION 07 - THERMAL & MOISTURE PROTECTION 07.01 AWNING ABOVE 07.02 DOWNSPOUTS 07.03 ROOM 412 TO BE WATERPROOFED USING SEALOFLEX WATERPROOFING SYSTEM OR APPROVED EQUAL, TO BE APPLIED TO PLYWOOD SUBFLOOR OF STAIRS, INCLUDING BASE FLASHING. INSTALL PER MFR. SPECS █ DIVISION 08 - OPENINGS 08.01 CASED PASS-THROUGH OPENING, SEE ID. 08.02 ACCESS PANEL TO NON-USABLE AREA BENEATH STAIRS 08.03 MATCH STOREFRONT TO (E) FRONT ENTRANCE 400-1 08.04 CASED OPENING FOR WALK-IN COOLER DOOR █ DIVISION 10 - SPECIALTIES 10.01 2A:K FIRE EXTINGUISHER IN WALL MOUNTED CABINET 10.02 2A:10 B:C FIRE EXTINGUISHER IN SEMI-RECESSED CABINET █ DIVISION 11 - EQUIPMENT 11.02 GRAB AND GO UNIT, SEE FOODSERVICE 11.03 KITCHEN EQUIPMENT. SEE FOODSERVICE, TYPICAL. 11.04 FOOD SERVICE EQUIPTMENT, SEE FOODSERVICE 11.06 CONDENSING UNIT WITH HOUSEKEEPING PAD, SEE FOODSERVICE █ DIVISION 12 - FURNISHINGS 12.01 COUNTERTOP, SEE ID █ DIVISION 14 - CONYEYING EQUIPMENT 14.01 SHIFT EXISTING PLATFORM LIFT CONTROLS TOWARDS PLATFORM LIFT TO ACCOMMODATE FIRE RISER DOOR 14.02 INTELI-LIFT RST 250 LB. DUMBWAITER BY ELEVATION INNOVATION OR APPROVED EQUAL 0-A0.99 █ DIVISION 26 - ELECTRICAL 26.01 WALL RECESSED STEP LIGHTS ON EMERGENCY CIRCUT, TYP. 1 7/14/23 ADDENDUM#1 1 MECH23-0015 Jacksonville Office REGION 65 PHONE: (904) 463 - 6242 EMAIL: reg65@econair.com FOR QUESTIONS, CALL THE HOOD INFORMATION - JOB#6029929 1 2 5412 ESX-2 246 MISC-PSP ECON-AIR ECON-AIR 8' 10" 8' 10" 600 DEG 300 DEG I I HEAVY N/A 225 0 1987 0 3"14"1987 1859 -0.849"0 1669 430 SS WHERE EXPOSED 430 SS WHERE EXPOSED ALONE ALONE ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP TOTAL SUPPLY CFM HOOD CONSTRUCTION HOOD CONFIG END TO END ROW HOOD INFORMATION 1 2 CAPTRATE SOLO FILTER 6 20"16" 85% SEE FILTER SPEC 3 0 RECESSED ROUND NO WALL MNT 12"x48"x24"TANK FS 4.0/4.0 SC-111110MA 1 LIGHT 1 FAN YES NO 480 LBS 129 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT HOOD OPTIONS 1 2 3 BACKSPLASH 68.00" HIGH X 106.00" LONG 430 SS VERTICAL. WRAPPER CHANNEL - LEFT, RIGHT. RIGHT QUARTER END PANEL 27" TOP WIDTH, 0" BOTTOM WIDTH, 27" HIGH 430 SS. LEFT QUARTER END PANEL 27" TOP WIDTH, 0" BOTTOM WIDTH, 27" HIGH 430 SS. INSULATION FOR TOP OF HOOD. INSULATION FOR BACK OF HOOD. MIN 18 GAUGE HOOD. WRAPPER CHANNEL - FRONT, LEFT, RIGHT. OPTIONS ONLY: FIELD WRAPPER 4.00" HIGH X 106.00" LONG FRONT 430 SS. OPTIONS ONLY: FIELD WRAPPER 4.00" HIGH X 78.00" LONG LEFT 430 SS LENGTH INCLUDES: FRONT PSP. OPTIONS ONLY: FIELD WRAPPER 4.00" HIGH X 78.00" LONG RIGHT 430 SS LENGTH INCLUDES: FRONT PSP. HOOD NO TAG OPTION PERFORATED SUPPLY PLENUM(S) 2 Front 106"24"6" MUA MUA 12" 12" 28" 28" 834 834 0.257" 0.257" HOOD NO TAG POS LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG DIA CFM SP WALL-MOUNT UTILITY CABINET 1 WALL MNT 12"x48"x24"TANK FS 4.0/4.0 SC-111110MA 1 LIGHT 1 FAN 340.00 LBS UTILITY CABINET(S) HOOD NO LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY WEIGHT 1500500 FLOW RATE (CFM) 1000 0.00 0 0.50PRESSURE DROP (in. H20)PRESSURE DROP VS. FLOW RATE RR SPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTER A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURING LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND COMPONENTS WHEN ASSEMBLED. 2-INCH DEEP HOOD CHANNEL(S). TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO FRACTIONAL EFFICIENCY (%)0 0.1 20 40 1.0 PARTICLE DIAMETER (UM) 10.0 EFFICIENCY VS. PARTICLE DIAMETER 60 80 100 THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. TE ANS F ACCORDANCE No. 96 NFPA WITH BUILT IN SLIDTE R OCH BNRAN I , OR M .YRORLAI GNTS BATCAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96. NSF STANDARD #2. UL STANDARD #1046. INT. MECH. CODE (IMC). ULC-S649. 1.00 1.50 2.00 2.50 3.00 3.50 MANUFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARK ARRESTER. PATENT NUMBERS AC-PSP WALL (CANADA) - CA PATENT 2820509. AC-PSP (UNITED STATES) - US PATENT 7963830 B2. AC-PSP ISLAND (CANADA) - CA PATENT 2520330. EXHAUST HOODS ND-2/BD-2/SND-2 (CANADA) - CA PATENT 2520435 C. LOCATION DATE DWG # REV. JOB DRAWN BY JOB # SCALE ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 8/14/2023 1 Atlantic Beach, FL, 32233 3/8" = 1'-0" 6029929 reg65 Atlantic Beach Country Club (alternate) MECH23-0015 GREASE DUCT & CHIMNEY SPECIFICATIONS: PROVIDE GREASE DUCT EQUAL TO ECON-AIR MODEL "EDW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "EDW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "EDW" DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATION GUIDE. PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "EDW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12". DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO ECON-AIR MODEL "EDW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. § ECON-AIR RECOMMENDS THE USE OF LISTED, PRE-FABRICATED ROUND GREASE EXHAUST DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM, MINIMIZE INSTALLATION AND INSPECTION TIMES, AND ENSURE DUCT IS LIQUID TIGHT CUSTOMER APPROVAL TO MANUFACTURE: APPROVED AS NOTED APPROVED WITH NO EXCEPTION TAKEN REVISE AND RESUBMIT SIGNATURE YOUR TITLE DATE HEIGHT REQUIRED TO VERIFY THAT HOOD FITS SPACE AND TO SIZE THE ENCLOSURE PANELS ___' - ___" VERIFY CEILING HEIGHT HVAC DISTRIBUTION NOTE HIGH VELOCITY DIFFUSERS OR HVAC RETURNS SHOULD NOT BE PLACED WITHIN TEN (10) FEET OF THE EXHAUST HOOD. PERFORATED DIFFUSERS ARE RECOMMENDED. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. SUPPLY PLENUM HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR SUPPLY PLENUM). SUPPLY PLENUM HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR PSP HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) SYSTEM DESIGN VERIFICATION (SDV) IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE. ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES. DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. LOCATION DATE DWG # REV. JOB DRAWN BY JOB # SCALE ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 8/14/2023 2 Atlantic Beach, FL, 32233 3/8" = 1'-0" 6029929 reg65 Atlantic Beach Country Club (alternate) 54" 1" LAYER OF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 3" § 53"53" 11" ∅14" U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. PLAN VIEW - HOOD #1 8' 10.00" LONG 5412ESX-2 8' 10"NOM./8' 10.00"OD. 24" 26 1/2" 12" 12" 28" 53" 12" 12" 28" PLAN VIEW - HOOD #2 8' 10.00" LONG 246MISC-PSP BACKSPLASH HEIGHT - BACKSPLASH IS NOT INSULATED AND IS UNSUITABLE FOR INSTALL AGAINST COMBUSTIBLE WALLS BACKSPLASH PANELS SLIDE INTO DIVIDER BAR NON-COMBUSTIBLE WALL LENGTH LOCATION DATE DWG # REV. JOB DRAWN BY JOB # SCALE ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 8/14/2023 3 Atlantic Beach, FL, 32233 3/8" = 1'-0" 6029929 reg65 Atlantic Beach Country Club (alternate) REMOTE HOOD CONTROLS/FIRE SYSTEM UTILITY CABINET 12.00" 48.00" WALL-MOUNT UTILITY CABINET ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH UTILITY CABINET HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. CABINET TO BE HUNG BY HOOD INSTALLER. SEE UTILITY CABINET SCHEDULE FOR CABINET SIZE. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). UTILITY CABINET HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. (HARDWARE BY INSTALLER) 1" LAYER OF INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. BACKSPLASH 68.00" HIGH X 106.00" LONG. 1" LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 27" 27" LEFT AND RIGHT QUARTER END PANELS. EQUIPMENT BY OTHERS. 27" MIN. 48.0" MAX. 68" 80" 12" NOM. 54" SECTION VIEW - MODEL 5412ESX-2 HOOD - #1 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 6" 2 3/4" SUPPLY RISER WITH VOLUME DAMPER. 24" 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. 6" LOCATION DATE DWG # REV. JOB DRAWN BY JOB # SCALE ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 8/14/2023 4 Atlantic Beach, FL, 32233 3/8" = 1'-0" 6029929 reg65 Atlantic Beach Country Club (alternate) FIRE SYSTEM INFORMATION - JOB#6029929 1 TANK FS 4.0/4.0 28 WALL UTILITY CABINET LEFT N/A FIRE SYSTEM NO TAG TYPE SIZE FLOW POINTS INSTALLATION SYSTEM LOCATION ON HOOD GAS VALVE(S) 1 SC ELECTRICAL 2.000 ECON-AIR FIRE SYSTEM NO TAG TYPE SIZE SUPPLIED BY FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. 12" ∅14" HOOD FRONT HOOD BACK HOOD # 1 JOB # 6029929 FS # 1 MODEL: SND-2 SIZE: 54"x12" LENGTH: 8' 10"TANK OVERLAPPINGPROTECTION - 30HIGH PROXIMITY106.00" L X30.00" DDUCT S 360 OL-F OL-F 25.00" 13.50" OL-F SH I P L O O S E * 13.50" OL-F SH I P L O O S E * 13.50" OL-F SH I P L O O S E * 13.50" OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. (47.25")SHIP LOOSE*12.00"27.33"27.33"27.33"12.00" SLPCON-30FT KIT SLPCON-30FT KIT 12.00" 48.00" - SYSTEM REQUIRES A MINIMUM OF 7 FT OF EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES. EACH 90 DEGREE ELBOW ADDS 1.3 FT OF EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS 1 631 7 2 5 24.00" HANGING ANGLES IN EACH CORNER. 48.00" TO HOOD# 1 WALL-UC ALTERNATE FIELD-CONNECTION POINTPLENUM NOTES - FIELD PIPE DROPS AS SHOWN PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS. - FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED. - SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED SHIPPED LOOSE TO BE FIELD-INSTALLED. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION. - IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS. - OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS JOB #: 6029929. JOB NAME: ATLANTIC BEACH COUNTRY CLUB (ALTERNATE). SYSTEM SIZE: TANK-SP-2-WC TOTAL FP REQUIRED: 28. HOOD # 1 8' 10.00" LONG x 54" WIDE x 12" HIGH. RISER # 1 SIZE: 14" DIA. HOOD # 1 METAL BLOW-OFF CAPS INCLUDED. - HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY HORIZONTAL RUNS OVER 25 FT IN LENGTH. - MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITIONAL DOWNSTREAM DETECTION. PRESSURE SUPERVISION SWITCH. PRIMARY ACTUATOR RELEASE. 4 GALLON TANK. 7 6 5 4 2 1 LEGEND - FIRE CABINET TANK SYSTEM PRIMARY HOSE ASSEMBLY. SECONDARY ACTUATOR RELEASE.3 SECONDARY HOSE ASSEMBLY. REMOTE MANUAL ACTUATION DEVICE. 1" LAYER OF INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. BACKSPLASH 68.00" HIGH X 106.00" LONG. 1" LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 27" 27" LEFT AND RIGHT QUARTER END PANELS. EQUIPMENT BY OTHERS. 27" MIN. 48.0" MAX. 68" 80" 12" NOM. 54" SECTION VIEW - MODEL 5412ESX-2 HOOD - #1 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 13 1/2" VOLTAGESIZETYPE GAS VALVE SIZING GAS VALVE DIMENSIONS DIM "A"DIM "B"DIM "C"DIM "D"DIM "F"DIM "G" PART NUMBERS GAS VALVES AND STRAINERS INSTALLATION MIN. INLET PRESSURE MAX. INLET PRESSURE FLOW AT 1 IN.W.C. DROP NATURAL GAS FLOW AT 1 IN.W.C. DROP PROPANE MOUNTING ORIENTATION GAS VALVE PART NUMBER STRAINER PART NUMBER GAS VALVE/STRAINER KIT ELECTRICAL 2"120 VAC 4417K6882142807-5/8"6-3/8"7-1/4"7-13-16"15-5/8"13-15/16"(SC)EGVA2GAS VALVE FOR FS#1 0 PSI (0 IN.W.C.) 5 PSI (138 IN.W.C.) 2,940,500 BTU/HR 1,908,048 BTU/HR HORIZONTAL/ VERTICAL FLOW. ELECTRIC GAS VALVE. STRAINER. 4" MIN. DIM "G" DIM "D" DIM "A" DIM "F" DIM "C" DIM "B" ALL GAS VALVES/STRAINERS TO CALCULATE GAS FLOW FOR OTHER THAN 1 IN.W.C. PRESSURE DROP NEW BTU/HR = (BTU/HR AT 1 IN.W.C. PRESSURE DROP) X NEW PRESSURE DROP 0.5 TO CALCULATE GAS FLOW FOR OTHER THAN 0.64 SPECIFIC GRAVITY NEW BTU/HR = (BTU/HR AT 0.64) X (0.64 / NEW SPECIFIC GRAVITY) 0.5 . CALCULATIONS PROPER CLEARANCE MUST BE PROVIDED IN ORDER TO SERVICE THE STRAINERS A MINIMUM OF 4" CLEARANCE DISTANCE MUST BE PROVIDED AT THE BASE OF THE STRAINER CUSTOMER MUST VERIFY BTU CONSUMPTION AS WELL AS PRESSURE RATING SPECIFIC GRAVITY OF NATURAL GAS = 0.64, SPECIFIC GRAVITY OF LP = 1.52. LOCATION DATE DWG # REV. JOB DRAWN BY JOB # SCALE ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 8/14/2023 5 Atlantic Beach, FL, 32233 3/16" = 1'-0" 6029929 reg65 Atlantic Beach Country Club (alternate) FIELD CONFIRM REQUIRED GAS VALVE SIZE WITH PLUMBER. 2" VALVE SHOWN FOR REFERENCE ONLY. ELECTRICAL PACKAGE - JOB#6029929 1 SC-111110MA WALL UTILITY CABINET LEFT FACE MOUNT LEFT SIDE OF HOOD HOOD # 1 1 LIGHT 1 FAN SMART CONTROLS THERMOSTATIC CONTROL W/ RELAY ON/OFF WITH SUPPLY EXHAUST SUPPLY 1 1 0.750 0.750 115 115 8.9 8.9 NO TAG PACKAGE #LOCATION SWITCHES LOCATION QUANTITY OPTION FANS CONTROLLED TYPE ɸ HP VOLT FLA DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6029929 Atlantic Beach Country Club (... SC-111110MA 8/14/2023 INSTALL ECP #1-1 120V 1 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. BREAKER PANEL TO PRIMARY CONTROL PANEL Responsibility: Electrician BREAKER PANEL PRIMARY CONTROL PANEL BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BREAKER 1PH CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. Hot Neutral H1 N1 120 V 15 A Ground GND 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 BREAKER 1PH MCA: MOCP: Hot Neutral L1 FN1 GND Ground EXH-1 115 V 11.1 A 20 A BREAKER 1PH MCA: MOCP: Hot Neutral L2 FN2 GND Ground SUP-2 115 V 11.1 A 20 A CONTROL PANEL TO FANS Responsibility: Electrician PRIMARY PANEL FANS Load Wiring WIRE DIRECT TO STARTER WIRE TO DISCONNECT FLA: HP: VOLT: T1 T2 EXH-1 LEG 1 / HOT LEG 2 / NEUTRAL GND GROUND C-1 01FAN: 8.9 0.750 115 V Load Wiring WIRE DIRECT TO STARTER BLACK WHITE GREEN WIRE TO FACTORY PROVIDED CONDUIT DROP FLA: HP: VOLT: T1 T2 LEG 1 / HOT LEG 2 / NEUTRAL GND GROUND C-2 SUP-2 02FAN: 8.9 0.750 115 V CONTROL PANEL TO ACCESSORY ITEMS Responsibility: Electrician CONTROL PANEL COMPONENT WIRE DIRECTLY TO CONTROL BOARD CAT-5 CONNECTION CONTROL PANEL REMOTE TO MOUNTED SWITCHES PLACE END OF LINE PLUG EOL120A IN EMPTY JACK. PN: EOL120A HMI J4 1 2 CONTROL PANEL HOOD LIGHTS TO 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD B1 W1 GND BLACK WHITE GREEN HOOD LIGHTS 1 CONTROL PANEL BACNET MSTP TO BACNET MSTP BMS BMS +- Gnd RS485 DDC-1 Shielded Twisted Pair RD BK RD BK Shield + - Gnd WIRE TO CONTROL BOARD. INSTALL SENSOR IN ROOM AWAY FROM HEAT SOURCES. DO NOT INSTALL SENSOR CONTROL PANEL ROOM TEMP TO SENSOR ON THE CEILING GRID, SEE MANUAL. GROUPS: T1A T1B ROOM TEMP WIRE TO CONTROL BOARD. SENSOR MOUNTED IN EXHAUST DUCT CONTROL PANEL DUCT SENSOR TO T2A T2B HOOD 1 RISER 1 CONTROL PANEL GAS VALVE TO 120V ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. GAS N1 HOT TO GAS VALVE NEUTRAL GAS SOLENOID THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS CONTROL PANEL EXTERNAL SIGNAL FOR SHUNT TRIP ST TERMINAL IS ENERGIZED IN FIRE CONDITION. CONTROL PANEL EXTERNAL SIGNAL FOR CONTACTOR COIL KS TERMINAL IS DE-ENERGIZED IN FIRE CONDITION. ST N1 NEUTRAL FROM SHUNT COIL HOT TO SHUNT COIL SHUNT COIL KS N1 NEUTRAL_TO_CONTACTOR_COIL HOT_TO_CONTACTOR_COIL CONTACTOR_COIL SPARE CONTACTS WILL MAKE CONTROL PANEL ON/OFF WITH DRY CONTACT SUPPLY FAN COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. GROUP 1 SFC1 SFO1 COMMON NORMALLY OPEN SFC2 SFO2 COMMON NORMALLY OPEN CONTROL PANEL EXTERNAL TO SWITCH SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONE1 FANS AND LIGHTS H1 IO1 BMS SWITCH C NO SPARE CONTACTS WILL MAKE CONTROL PANEL ON/OFF WITH DRY CONTACT EXHAUST FAN COMMON TO NORMALLY OPEN WHEN EXHAUST FAN IS ON. GROUP 1 EFC1 EFO1 COMMON NORMALLY OPEN EFC2 EFO2 COMMON NORMALLY OPEN CONTROL PANEL GAS VALVE TO 24V DC ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. (NOT NEEDED IF USING 120V GAS VALVE). LGV N1D POSITIVE TO GAS VALVE NEGATIVE GAS SOLENOID CONTROL PANEL TO FIRE SYSTEM Responsibility: ALARM CONTRACTOR CONTROL PANEL COMPONENT CONTROL PANEL BUILDING SIGNAL FOR FIRE ALARM PANEL AL1 AL2 J9 BUILDING ALARM PANEL FIRE INPUT WIRE DIRECTLY TO CORE CIRCUIT BOARD. AL1 WILL MAKE AL2 IN FIRE CONDITION. CONTROL PANEL BUILDING SIGNAL FOR TROUBLE TROUBLE RELAY CONTACTS WILL MAKE TBC TO TBL IN TROUBLE CONDITION. BUILDING ALARM PANEL ALARM TBC TBL COMMON NORMALLY CLOSED CONTROL PANEL TO FIRE SYSTEM Responsibility: CERTIFIED INSTALLER CONTROL PANEL COMPONENT FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. 21 22 23 24 FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat CONTROL PANEL MOUNTED FIRE TO DUCT DETECTION STAT(S) FIRE STATS 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 CONTROL PANEL SYSTEM PULL TO FIRE STATION MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 is mounted on J10, remove the jumpers and wire in the supervised actuation loop. Microswitch MS-01 is optional for fire system interlock. Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master FS panel(s) in each manual activation loop for simultaneous activation. See Fire system drawings for more information. 101 102 103 104 AUX-01 AU1 AU2 PULL STATION MS-01 C NO Micro SW MAD-01 C NO Manual Actuation Device Adjacent FS Panel CAT-5 CONNECTIONCONTROL PANEL MASTER FS TO BOARD. PLACE END OF LINE PLUG EOL120A IN EMPTY JACK. PN: EOL120A CORE PCB ADDITIONAL DEVICES MAY BE INLINE. ECPM03 UNLESS VFD, PCU, OR OTHER COMPONENT IN SERIES. J3 J5 J6 CONTROL PANEL MASTER FS TO PANEL WIRE TO LIKE TERMINALS IN ALL CORE PANELS THAT MUST ACTIVATE TOGETHER. SET MASTER & SLAVE DIP SWITCHES PER FIRE SYSTEM SHIELDED TWISTED PAIR INTERLOCK NETWORK MASTER CORE MANUAL. CA CB CC BLACK RED SHIELD CA CB CC LOCATION DATE DWG # REV. JOB DRAWN BY JOB # SCALE ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 8/14/2023 6 Atlantic Beach, FL, 32233 3/8" = 1'-0" 6029929 reg65 Atlantic Beach Country Club (alternate) WALL MOUNT UTILITY CABINET CAS ELECTRIC WET CHEMICAL PROTECTION ELECTRICAL DETAIL 02/11/2021 Rev. 02 ELECTRICIAN: 1. WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC 2. WIRE ALL FANS PER INCLUDED SCHEMATIC 3. WIRE SHUNT TRIP BREAKER (OPTIONAL) 4. WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL) 5. WIRE GAS VALVE NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS EXHAUST HOOD 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN GAS ELECTRIC ELECTRICAL CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS SHUNT TRIP BREAKER (OPTIONAL)ST & N1 BREAKER COIL (A1 & A2) 120 VAC < 4 AMPS ST TO A1 ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER UDS APPLIANCE KILL SWITCH (OPTIONAL)KTS & N1 KTS & N1 120 VAC < 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL)AU1, AU2 SOLENOID 120 VAC < 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL GAS VALVE LGV & N1D (IF 24 VDC) GAS & N1 (IF 120 VAC) RED/RED/GREEN 24 VDC OR 120 VAC < 1.0 AMPS IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED, AND GREEN TO GROUND IF 120 VAC - 2 WIRES & GROUND GAS TO RED, N1 TO RED, AND GREEN TO GROUND SHUNT TRIP BREAKER (OPTIONAL) -2 WIRES, 120VAC -ST TO A1 ON SHUNT BREAKER -NEUTRAL TO A2 ON SHUNT TRIP BREAKER POWER TO ELECTRIC APPLIANCE CONTROL PANEL POWER -2 WIRES & GROUND -120 VAC, 15 AMP SERVICE -WIRE TO H1 AND N1, GROUND -POWER MUST NOT ORIGINATE FROM SHUNT TRIP BREAKER GAS VALVE POWER -2 WIRES & GROUND -24 VDC WIRE TO LGV & N1D -120 VAC WIRE TO GAS &N1 GAS VALVE -STRAINER MUST BE INSTALLED UPSTREAM OF VALVE COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6029929 Atlantic Beach Country Club (... SC-111110MA 8/14/2023 INSTALL ECP #1-3 Fire System #1 TANK FS - 4.0/4.0. FS-1: MASTER WALL MOUNT UTILITY CABINET CAS ELECTRIC WET CHEMICAL PROTECTION LOW-VOLTAGE DETAIL 02/05/2018 Rev. 1 ALARM CONTRACTOR: 1. WIRE MANUAL ACTUATION DEVICE(S), REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS 2. COMPLETE FINAL HOOKUP OF SYSTEM 3. VERIFY FINAL FIRE SYSTEM TEST ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN EXHAUST HOOD ELECTRIC GAS NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS ALARM CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS MANUAL ACTUATION DEVICE(S) 101 AND 104 102 AND 103 1 & 2 24 VDC < 1.0 AMPS WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103 WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104 JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B REMOTE FIRESTAT SENSOR(S) 21 AND 24 22 AND 23 BLACK AND WHITE 24 VDC < 1.0 AMPS WIRE FIRE SENSOR WHITE WIRES BETWEEN HOOD CORE PANEL TERMINALS 22 AND 23 WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24 HIGH TEMP (842°F) #CW04427 (WHT) & #CW04427B (BLK)WIRE OR SIMILAR ONLY IF RAN OVER TOP OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE; SEE FIGURE 1 FIRE ALARM CONTACT AL1, AL2 VARIES 50V MAX (AC/DC) UP TO 1 AMP FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE CORE ELECTRICAL CONTROL PANEL CORE INTERLOCK(S)ILA, ILB, ILC ILA, ILB, ILC RS-485 COMMUNICATIONS SIGNAL CORE SYSTEM (1) ILA, TO CORE SYSTEM (2) ILA. CORE SYSTEM (1) ILB, TO CORE SYSTEM (2) ILB. CORE SYSTEM (1) ILC, TO CORE SYSTEM (2) ILC. USE BELDEN# 88760 OR SIMILAR WIRE TROUBLE CONTACT TBC, TBL, TOK VARIES MAX 120 VAC UP TO 6 AMPS WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL <1.0 AMPS TYPICAL CONNECTION CAT5 CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR WIRELESS ROUTER WITH VALID INTERNET CONNECTION 42 TO 48 INCHES ABOVE FLOOR LEVEL TO CENTER OF PUSH STATION MANUAL ACTUATION DEVICE 10 TO 20 FEET FROM HOOD LOCATED NEAR POINT OF EGRESS FROM HOOD MANUAL ACTUATION DEVICE WIRES -4 WIRES, 24VDC WIRE (TERMINAL 1) BETWEEN 102 AND 103 -WIRE (TERMINAL 2) BETWEEN 101 AND 104 -ADDITIONAL PULL STATIONS WIRED IN SUPERVISED LOOP -USE BELDEN #6320UL OR SIMILAR WIRE -SEE FIGURE 2 MANUAL ACTUATION DEVICE PART #STI-SS2431 PROTECTIVE COVER MUST BE INSTALLED SUPERVISED LOOP -4 WIRES, 24VDC CONNECT BLACK WIRES BETWEEN 21 AND 24 IN PANEL, CONNECT WHITE (OR RED) WIRES BETWEEN 22 AND 23 IN PANEL -ADDITIONAL FIRESTATS, WIRED IN SUPERVISED LOOP -USE HIGH TEMP (842°F) #CW04427 (WHT) & #CW04227B (BLK)WIRE ONLY IF RAN OVER TOP OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE -SEE FIGURE 1 CORE COMMUNICATIONS CABLE -CAT5 CABLE MUST BE INSTALLED TO A LOCAL AREA NETWORK WITH VALID INTERNET ACCESS VIA ETHERNET SWITCH OR WIRELESS ROUTER CORE INTERLOCK -2 WIRES + SHIELD -USE BELDEN#88760 OR SIMILAR WIRE -SEE FIGURE 3 FIRE ALARM PANEL FIRE ALARM CONTACT -2 WIRES WIRED TO NORMALLY OPEN CONTACTS (CLOSES IN FIRE CONDITION) -CORE CONTROL PANEL AL1 AND AL2 -SEE FIGURE 2 TROUBLE CONTACT -2 WIRES TO NORMALLY OPEN CONTACTS (CLOSE IN TROUBLE CONDITION) -CORE PANEL TERMINALS TBL AND TBC -SEE FIGURE 4 COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6029929 Atlantic Beach Country Club (... SC-111110MA 8/14/2023 INSTALL ECP #1-4 Fire System #1 TANK FS - 4.0/4.0. FS-1: MASTER WALL MOUNTED CAS ELECTRIC WET CHEMICAL 02/05/2015 Rev. 16 AL1 AL2 END OF LINE DEVICE WIRING CONNECTIONS FOR FIRE ALARM CONTACT FIGURE 2 CORE CONTROL PANEL FIRE ALARM CONTACT ALARM INPUT BUILDING FIRE ALARM SHIELDED TWISTED PAIR ILA ILC ILB ILA BK ILB RD BK RD WIRING CONNECTIONS FOR CORE INTERLOCK FIGURE 3 ILC ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES SUPERVISION SWITCH 1 2 C BUILDING FIRE ALARM TROUBLE INPUT CORE CONTROL PANEL TROUBLE CONTACT NO C NC 1 C 2 SUPERVISION SWITCH SUPERVISION SWITCH END OF LINE DEVICE TBC TBLTOK WIRING CONNECTIONS FOR TROUBLE CONTACT FIGURE 4 BK-C BK-C 21 22 23 24 J2-1 J2-2 J2-4 J2-3 21 BK-C 101 102 103 104 J10-1 J10-2 J10-4 J10-3 21 BK-C WIRING CONNECTIONS FOR FIRESTAT LOOP FIGURE 1 WIRING CONNECTIONS FOR MANUAL ACTUATION LOOP FIGURE 1A BREAK WIRE BEFORE INSERTING INTO TERMINALS FIRE STAT-2 FIRE STAT-1 NO-WH (OR RD) NO-WH (OR RD) BREAK WIRE BEFORE INSERTING INTO TERMINALS NO-WH (OR RD) MANUAL ACTUATION DEVICE NO-WH (OR RD) MANUAL ACTUATION DEVICE MICROSWITCH/ NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS USE BELDEN #6320UL OR SIMILAR WIRE DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 PROTECTION LOW-VOLTAGE FIGURES FS-1: MASTER WH BK A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CIRCUIT BOARDS MOTOR POWER CIRCUIT PANEL LID COMPONENT LIST LABEL DESCRIPTION ST-X varies Starter OL-X varies Overload C-X varies Contactor 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 PS-1 MDP18-24A-1C Power Sup. 24VDC BK RA-x 34.110.0184.0 120V Relay DPDT WH RA-x 34.110.0184.0 120V Relay DPDT GR UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. N1 H1 DC-GNDDC+8H1 7PCU 6ST 5KS 4KTS 3GAS 2AR1 1N1 120VJ9 5OV1 4SF1 3EF1 2B1 1IO1 120VJ7 AR1 H1 2x N1 2x B1 EF1 SF1 BK IO1 N1 N1 BK BK BK JUMPER W1 BK 14AWG BK 64 RD-1 BL PR DC+RO1 RD-x 34.110.0188.0 24VDC Light Relay BK BK WH SF1 WH EF1 7 8RA-3 7 8RA-2 A1 A2C-2 A1 A2C-1 8 7RD-1 24V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 J6 N1N1 ON/OFF WITH EXH ON/OFF WITH SUP N1RO1 NH FAN PANEL COOLING DRY CONTACTS (SHOWN DE-ENERGIZED)DRY CONTACTS (SHOWN DE-ENERGIZED) HOOD LIGHTS AR1 H1 JUMPER FIRE SYSTEM BK BK BK GAS KS ST C RA-3-1 NO EFC1 EFO1 14 AWG YW C RA-3-2 NO EFC2 EFO2 14 AWG YW ECPM03 J10 IL1AIL1BJUMPER MAKE UP AIR INTERLOCK. NOTE: Configure ECPM03 for CORE J3 ECPM03 or Previous EOL J5 MASTER CORE FIELD WIRED C RA-2-1 NO SFC1 SFO1 14 AWG YW C RA-2-2 NO SFC2 SFO2 14 AWG YW SC-24 X 18 X 8.62 BOX CONTROL INPUT 120V H1=LINE, N1=NEUTRAL, 15A BREAKER. DO NOT CONNECT TO SHUNT TRIP BREAKER. SEE INSTALLATION SCHEMATIC FOR ADDITIONAL REQ. DDC-1 CAS_BACNET_GATE... BACNET MODULE LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREENWH/BLBLH1N1DC-DC+LN -+ PS-01 AC 24V GNDDC KSKS BK KS J1 ECPM03 BK BK GAS ST DDC-1 BACnet Pwr+ Pwr-+-GNDRS485 Field DC- DC+ Ethernet Protocessor cat5 BK EF1 PRWH GR/YWWH/BLBLNH FAN SECONDARY PANEL COOLING IF NECESSARY EF1 WHBK JUMPER ECPM03 J10 IL2AIL2BTERMINAL GAS USED FOR 120V POWERED GAS VALVES ONLY DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6029929 Atlantic Beach C... FACTORY SC-111110MA 8/14/2023 ECP #1-6 120V 1 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. BK WH T1 T2 T3 L1 L2 L3 1413 CONT: FLA: MTR: HP: L1 FN1 C-114 AWG 1 PH 20 A 115 V EXH-1 100-K12D10 8.9 0.750 BK WH T1 T2 T3 L1 L2 L3 1413 CONT: FLA: MTR: HP: L2 FN2 C-214 AWG 1 PH 20 A 115 V SUP-2 100-K12D10 8.9 0.750 A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CORE FIRE PROTECTION COMPONENT LIST LABEL DESCRIPTION 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 24 VOLT BATTERY PACK 5 AMP FUSE RD SHIELDED TWISTED PAIR PCB-2 J3-2 J4-1 J3-11 J4-3 J4-2 J4-8 J4-9 J4-12 J3-14 J4-5 J3-13 J3-4 J4-6 J3-10 J2-1 J2-2 J2-3 J2-4 J7-2 J7-3 J7-1 J3-1 J3-3 RD RD BR RD ALL 18AWG RD BK ORRD PKRD BRRD RD OR/BL BK 18AWG BK BK J3-5 J1-1 J1-2 RD BK BK RD FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. + + RD BK BK RD Shield BK RD RS-485 CORE INTERLOCK NETWORK. Connection to other CORE Panels or Communication Module. See Installation Schematic for Connection. N1D 3xH1D3x DISCONNECT J1 21 22 23 24 16AWG WH N1 H1 PN: 1606-XLP-60EQ Adjust power supply to 27.5 Volts with an accurate Digital Volt Meter or with an HMI plugged into the CORE board. NL +-PS-02 60W GR BK GND PCB-2 PCBCORE-APP CORE PCB PS-02 1606-XLP-60E CORE POWER SUPPLY WS-x varies Water Solenoid LT-06 PNL-1163-0UR 24V Red Ind. Light LL-01 AQ5510 Surf. Level Sensor AA-01 SCE120LA3FP1B Audible Alarm PB-01 D7-F2X11 Prime/Reset Switch SW-04 BZ-2RQ1-A2 Tamper Switch SP-1 50000-805 Surfactant Pump PB-01 Prime / Reset A2A1 RD-20 Trouble Relay A2A1 RD-17 Fire Relay DRY CONTACTS (SHOWN DE-ENGERGIZED) AA-01 Audible Alarm SW-04 Door Tamper Switch C NO FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. Factory mounted hood sensors will be terminated at junction box on top of hood. GV-1 varies 24v DC Gas Valve INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. 11 RD-18-1 14 YW J3-16 J3-8 LT-6 R FIRE INDICATOR DIP Switch ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. RD/GNRD A2A1 RD-19 Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS Kill Switch, wire EKC and EKS terminals to like terminals in UDS panel. 12 11 RD-19-1 14 EKC EST EKS YW INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. 11 RD-18-1 14 YW RD OR/BL A2A1 RD-18 Auxiliary Interlock Relay FS-XX 12-F28021-000360 Duct Fire Sensor LT-05 PNL-1163-0UY 24V YLW Ind. Light PS-01 Station STI-SS2431 Remote Puill/Push FOR SHIPMENT J10-1 J10-2 J10-3 J10-4 RD BK BK RD 101 102 103 104 MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 should be mounted on J10 if there is no manual actuation device and no microswitch. MAD-01 C NO Manual Actuation Device MS-01 C NO Micro SW 1 2 3 4 5 6 7 8 SW1OPEN PUT END OF LINE PLUG IN EMPTY RJ45 J3 ECPM03 UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. CAT-5 WIRING (MASTER ONLY) FIELD WIRED IF REMOTE PREWIRE RD-XX PLC-RPT-24DC/21 24VDC Phoenix Relay AUX-01 AU1 AU2 Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master CORE panel(s) in each manual activation loop for simultaneous activation. AU1/AU2 will have continuity for 10 seconds if adjacent panel goes into fire condition, activating this CORE Panel but allowing for a reset after 10 seconds. NOTE: AU1/AU2 terminals of CORE Panel should not be wired into its own manual activation loop. Adjacent CORE Panel Master CORE set DIP SW 8 to CLOSED position. Slave CORE with address 1 set DIP SW 8 to CLOSED position. All other CORES set DIP SW 8 OPEN. 18AWG LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN FIRE INDICATOR FAULT CONDITION FLASH CODES 2 Release Solenoid 3 Pressure Switch 4 Auxiliary Fault 5 Microcontroller Fault 6 N/A 7 Supervised Loop 8 Ground Fault 9 Surfactant Low 10 Battery Voltage Low 11 AC Power Failure 12 Door Tamper Switch 13 Test Mode 14 CORE Interlock Network 15 Fault on Hood in Interlock Network 16 Fault on PCU in Interlock Network FIRE ALARM SYSTEM DRY CONTACTS. Termials AL1 & AL2 make in FIRE. To Building Fire Alarm Panel J9 AL1 AL2 J3-7 FIRE SYSTEM DRY CONTACTS. Dry contacts will make C2 to AR2 when system is armed. 12 11 RD-17-1 C2 AR2 14 AWG YW TROUBLE RELAY. Contact terminals TBC & TBL make if there is trouble. Contact terminals TBC & TOK make if the system is ok. 12 11 RD-20-1 14 TBC TBL TOK YW RD PS OR J4-9 PS EWC-PRESSURE Pressure Switch PR RS SW-05-1 Test Armed 3 4 YW RS-1 RELEASE SOLENOID BLBR RD OR SW-05-3 Test Armed 3 4 J4-13 SW-05 ZB5AD2 TEST/ARM Switch RS2 PR SW-05-2 Test Armed 3 4 YW PS-1 Pressure Switch WH 14 PWS-01 24VDC 18W POWER 24VDC Power Suppl CA CB CC AU1AU1 AU2AU2 TR2 MAD-01 DEVICE MANUAL ACTIVATION GAS VALVES SHOULD BE WIRED TO MASTER CORE BOARD ONLY. RDRD GV-1 24V DC Gas Valve LGV PK TERMINAL LGV USED FOR 24VDC POWERED GAS VALVES ONLY. (2nd Contact) BK WH H1 N1NH FAN PANEL COOLING DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6029929 Atlantic Beach C... FACTORY SC-111110MA 8/14/2023 ECP #1-7 Fire System #1 TANK FS - 4.0/4.0. FS-1: MASTER DUCTWORK #1 PARTS - JOB#6029929 DOUBLE WALL TAG PART #CFM GPM ZONE COVEREDBY SP WEIGHT VELOCITY QTY DESCRIPTION P1 EDW1490DWASY-3Z-S 1987 -0.1733 40.20 1858.72 1 DOUBLE WALL DUCT - 14" INNER 90 DUCT - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P2 EDW1447DWLT-3Z-S 1987 -0.024 76.70 1858.72 1 DOUBLE WALL DUCT - 14" INNER DUCT, 47" LONG - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P3 ASSEMBLED W/P17 EDW14DWTEASY-3Z-S 1987 1 -0.013 48.60 1858.72 1 DOUBLE WALL DUCT - 14" INNER TEE DUCT - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P4 EDW1447DWLT-3Z-S 1987 -0.0242 76.70 1858.72 1 DOUBLE WALL DUCT - 14" INNER DUCT, 47" LONG - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P5 EDW1435DWLT-3Z-S 1987 -0.0181 56.96 1858.72 1 DOUBLE WALL DUCT - 14" INNER DUCT, 35" LONG - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P6 EDW1427DWAJD-3Z-S 1987 -0.0087 60.65 1858.72 1 DOUBLE WALL ADJUSTABLE DUCT - 14" INNER DUCT - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. MIN LENGTH = 11" / MAX LENGTH = 24.5" / ADJUSTMENT = 13.5" / ADJUSTABLE SECTION MAY NEED TO BE CUT. INCLUDES SINGLE AND DOUBLE WALL "V" CLAMPS. P7 ASSEMBLED W/P14 EDW14DWTEASY-3Z-S 1987 1 -0.013 48.60 1858.72 1 DOUBLE WALL DUCT - 14" INNER TEE DUCT - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P8 EDW1417DWLT-3Z-S 1987 -0.009 27.43 1858.72 1 DOUBLE WALL DUCT - 14" INNER DUCT, 17" LONG - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P9 EDW1447DWLT-3Z-S 1987 -0.024 76.70 1858.72 1 DOUBLE WALL DUCT - 14" INNER DUCT, 47" LONG - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P10 EDW1490DWASY-3Z-S 1987 -0.099 40.20 1858.72 1 DOUBLE WALL DUCT - 14" INNER 90 DUCT - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P11 ASSEMBLED W/P12 EDW1427DWAJDTP-3Z-S 1987 -0.01 60.28 1858.72 1 DOUBLE WALL ADJUSTABLE DUCT TRANSITION PLATE - 14" INNER DUCT - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. MIN LENGTH = 11" / MAX LENGTH = 24.5" / ADJUSTMENT = 6.5" / ADJUSTABLE SECTION MAY NEED TO BE CUT. INCLUDES SINGLE AND DOUBLE WALL "V" CLAMPS. P12 ASSEMBLED W/P11 EDW2314TP 1987 8.49 1858.72 1 DUCT TO CURB TRANSITION, 23" CURB TO 14" DUCT, 16 GA ALUMINIZED. USED ON BDU15, DU75 & 85. SYSTEM AT P12 -1.2653 0.00 P13 EDW2024SADKIT 8.01 1 DUCT - HORIZONTAL SADDLE SUPPORT KIT, USED WITH 20" OD - INCLUDES UNI-STRUT CUT TO LENGTH, DW2024SAD, & HARDWARE BAG 4. P14 ASSEMBLED W/P7 O=T EDW14DWACCDOORCOV-3Z-S 21.24 1 DOUBLE WALL DUCT - 14" INNER ACCESS DOOR & 20" ACCESS DOOR COVER WITH CLAMPS - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P15 EDW2024SADKIT 8.01 1 DUCT - HORIZONTAL SADDLE SUPPORT KIT, USED WITH 20" OD - INCLUDES UNI-STRUT CUT TO LENGTH, DW2024SAD, & HARDWARE BAG 4. P16 EDW2024SADKIT 8.01 1 DUCT - HORIZONTAL SADDLE SUPPORT KIT, USED WITH 20" OD - INCLUDES UNI-STRUT CUT TO LENGTH, DW2024SAD, & HARDWARE BAG 4. P17 ASSEMBLED W/P3 O=T EDW14DWACCDOORCOV-3Z-S 21.24 1 DOUBLE WALL DUCT - 14" INNER ACCESS DOOR & 20" ACCESS DOOR COVER WITH CLAMPS - 3 LAYERS ZERO CLEARANCE - 20" STAINLESS STEEL OUTER SHELL. P18 EDW2024SADKIT 8.01 1 DUCT - HORIZONTAL SADDLE SUPPORT KIT, USED WITH 20" OD - INCLUDES UNI-STRUT CUT TO LENGTH, DW2024SAD, & HARDWARE BAG 4. E3M-2000PLUS 0.80 3 DUCT - 3M FIRE BARRIER 2000 PLUS SILICONE - USED AS SEALANT TO SEAL DUCT JOINTS. EDW14DWCLASY-3Z-S 6.54 7 DUCT - 14" DUCT - 20" DOUBLE "V" CLAMP - 3Z INSULATION & SINGLE "V" CLAMP INCLUDED - ZERO CLEARANCE. TOTAL WEIGHT 744.21 LOCATION DATE DWG # REV. JOB DRAWN BY JOB # SCALE ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 8/14/2023 12 Atlantic Beach, FL, 32233 3/8" = 1'-0" 6029929 reg65 Atlantic Beach Country Club (alternate) SINGLE WALL FACTORY BUILT DUCTWORK - FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE INSTALLATION AND OPERATION MANUAL. - ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW. DUCT DIAMETER 8" 10'10'24' 10" 10'10'24' 12" 10'10'24' 14" 10'10'24' 16" 10'10'24' 18" 10'10'24' 20" 10'10'24' 22" 10'10'24' 24" 10'10'24' HORIZONTAL SUPPORT (FT) VERTICAL WALL SUPPORT (FT) VERTICAL CURB SUPPORT (FT) 10'10'24' 10'10'24' 10'10'24' 5" 6" 7" 26" 28" 30" 32" 10'10'24' 34" 10'10'24' 36" 10'10'24' 10'10'24' 10'10'24' 10'10'24' - DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR. - WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT. LOCATION DATE DWG # REV. JOB DRAWN BY JOB # SCALE ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 8/14/2023 13 Atlantic Beach, FL, 32233 3/8" = 1'-0" 6029929 reg65 Atlantic Beach Country Club (alternate) HORIZONTAL VERTICAL TYPE DUCT DIAMETER SUPPORT SPACING (FT) 2R (18") 8"7' 10"7' 12"7' 14"7' 16"7' 18"5' 20"5' 22"5' DOUBLE WALL FACTORY BUILT DUCTWORK - ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW. - FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE ENTIRE INSTALLATION AND OPERATION MANUAL - DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR. - WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT. 24"5' WALL SUPPORT (FT) CURB SUPPORT (FT) FLOOR SUPPORT (FT) 18'24'24' 3R & 3Z (5"-24")10'24'24' 3Z (26" -36")10'20'20' 26"5' 28"5' 30"5' 32"5' 34"5' 36"5' 2R & 2R HT (5"-16")20'24'24' 7"7' 6"7' 5"7' DO NOT LEAK TEST USING SMOKE BOMBS CONTAINING CHLORINES/CHLORIDES. CONSULT WITH CAPTIVEAIRE FOR PROPER LEAK TESTING METHODS. LOCATION DATE DWG # REV. JOB DRAWN BY JOB # SCALE ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 8/14/2023 14 Atlantic Beach, FL, 32233 3/8" = 1'-0" 6029929 reg65 Atlantic Beach Country Club (alternate)