610 Orchid St ROW23-0047 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
SMITH RYAN
CHRISTOPHER 610 ORCHID ST ATLANTIC BEACH FL 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
SOUTHEAST UTILITIES OF
GEORGIA, INC.5934 RICHARD ST JACKSONVILLE FL 32216
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
170911 0020 ATLANTIC BEACH SEC H
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
610 ORCHID ST RIGHT OF WAY COMMERCIAL
RIGHT OF WAY
COMCAST - UNDERGROUND
CABLE $0.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 12/5/2023
PERMIT NUMBER
ROW23-0047
ISSUED: 12/5/2023
EXPIRES: 3/4/2024
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
2 PUBLIC WORKS UTILITY ROAD CUT INFORMATIONAL
Notes:
Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut.
Repair must be shown on the plans.\r\r\r\r\r\r\r\r
3 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL
Notes:
Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of-
way for construction parking.
4 PUBLIC WORKS GRASS INFORMATIONAL
Notes:
Full site to be grassed.
5 PUBLIC WORKS REVISION INFORMATIONAL
Notes:
Any plan change must be submitted as a Revision to the Building Department.
6 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL
Notes:
All construction debris must be removed from job site by Contractor.
7 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
8 PUBLIC WORKS OTHER PUBLIC WORKS CONDITION INFORMATIONAL
Notes:
Provide GIS information at completion of project. Email to: Building-Dept@coab.us
2 of 2Issued Date: 12/5/2023
PERMIT NUMBER
ROW23-0047
ISSUED: 12/5/2023
EXPIRES: 3/4/2024
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
ROW23-0047
ROW23-0047
NO EXPECTED CONFLICTSWITH OTHER UTILITIESLOCATION:610 ORCHID ST, ATLANTIC BEACH,FL 32233TOTAL LENGTH OF JOB: 120' UGJOB DESCRIPTION: CATV DIRECTIONAL BOREPLACEMENTDRAWN BY: PCDATE:SCALE: NTS OF 6111/17/2023COMCAST PERMIT REQUEST FOR LOCATION:610 ORCHID ST, ATLANTIC BEACH, FL 32233THESE PLANS WERE PREPARED UNDER THERESPONSIBLE CHARGE OF COMCAST.JB1663113SANTA ROSAOKALOOSAWALTONHOLMESWASHINGTONBAYCALHOUNJACKSONGADSDENLIBERTYGULFFRAMKLINWAKULLALEONJEFFERSONTAYLORMADISONHAMILTONSUWANNEELAFAYETTEDIXIEGILCHRISTCOLUMBIAUNIONBAKERBRADFORDALACHUALEVYMARIONPUTNAMCLAYDUVALNASSAUST JOHNSFLAGLERVOLUSIALAKESUMTERCITRUSORANGESEMINOLEOSCEOLAPASCOHERNANDOPOLKHILLSBOROUGHPINELLASINDIAN RIVERBREVARDST LUCIEMARTINOKEECHOBEEHIGHLANDSHARDEEMANATEESARASOTADESOTOGLADESCHARLOTTELEEHENDRYPALM BEACHBROWARDCOLLIERMIAMI-DADEMONROEESCAMBIAVICINITY MAP:610 ORCHID ST, ATLANTIC BEACH, FL 32233DUVAL COUNTYROW23-0047
LOCATION:610 ORCHID ST, ATLANTIC BEACH,FL 32233TOTAL LENGTH OF JOB: 120' UGJOB DESCRIPTION: CATV DIRECTIONAL BOREPLACEMENTDRAWN BY: PCDATE:SCALE: NTS OF 6211/17/2023NO BACKREAMER USEDNO EXPECTED CONFLICTSWITH OTHER UTILITIESCOMCAST PERMIT REQUEST FOR LOCATION:610 ORCHID ST, ATLANTIC BEACH, FL 32233THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITHTHE FLORIDA DEPARTMENT OF TRANSPORTATION 2023-2024INDEX 102-602 & 102-660 AND APPLY TO: 610 ORCHID ST, ATLANTIC BEACH, FL 32233GENERAL NOTES:ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36" INCLUDING ROAD BORES AND DRIVEWAY BORES.ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BORE MACHINE, AS WELL ASCOUNTY APPROVED CONDUIT.ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 7' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PIT AND WILL USE 2" HDPE CONDUIT AT 36" DEPTH USING A5 1/4" DRILL HEAD.ALL PROPOSED AERIAL CATV WILL BE 0.700" DIAMETER AND WILL BE LASHED TO 0.250" STEEL STRAND CABLEUSING 0.125" STANDARD GALVANIZED LASHING WIRE.ALL PROPOSED AERIAL CATV CROSSING ROADWAYS WILL HAVE A MINIMUM MID-SPAN HEIGHT OF 18'-0".ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE A MINIMUM MID-SPAN HEIGHT OF 16'-0".LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO CONSTRUCTION.NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION.ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTER CONDITION BY GRADINGAND RE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITH BERMUDA SOD. "ALL CRACKED SIDEWALKS ARETO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OF WORK COMPLETION."WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONING EQUIPMENT. ANYDAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR.CONSTRUCTION NOTES:IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THE RIGHT-OF-WAY ANDEASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK THROUGH FIELDVERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES IN CASE OF OPEN EXCAVATION. VERIFICATION MAY BEPERFORMED DURING THE PERMITTEES WORK. IN THE CASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACEPRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT.THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACT WITHDETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL NOT BE LIMITEDTO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATOR SHALL BE HELD LIABLE FORDAMAGES CAUSED TO CITY'S/COUNTY'S/STATE INFRASTRUCTURE AND THE EXISTING FACILITIES OF THE OTHER UTILITYCOMPANIES.NO REAMER USEDROAD RIGHT-OF-WAYSANITARY SEWERSTORM SEWERCABLE TV SPAN (EXIST)FENCEGAS PIPELINEOH POWER LINEUG POWER LINEPROPERTY LINEBOTTOM BANKTOP BANKUNKNOWN UG UTILITYWATER LINECOMCAST AERIAL ROUTECOMCAST BORE ROUTECABLE TV BORE (EXIST)OH TELEPHONEUG TELEPHONEROAD CENTERLINEFIBER OPTIC CABLEMANHOLE (SANITARY SEWER)CABLE TV PEDESTALMANHOLE (STORM SEWER)EDGE OF PAVEMENTCABLE TV RISERUTILITY POLESSFIRE HYDRANTRAILROAD CENTERLINEELECTRIC PADRAILROAD CROSSING SIGNMHINLETCATCH BASINWATER VALVERAILROAD CROSSING SIGNALWATER VAULTTELEPHONE PEDESTALELECTRIC VAULTBORE PITCULVERTWATER MAIN / METERSIDEWALKDRIVEWAYUTILITY VAULTHAND HOLECATV VAULTCATV VAULTGAS VALVEWTEVWMVNCV
LOCATION:610 ORCHID ST, ATLANTIC BEACH,FL 32233TOTAL LENGTH OF JOB: 120' UGJOB DESCRIPTION: CATV DIRECTIONAL BOREPLACEMENTDRAWN BY: PCDATE:SCALE: NTS OF 6311/17/2023NO EXPECTED CONFLICTSWITH OTHER UTILITIESNO BACKREAMER USED620630640650798663395R/WEOPC/G R/WEOPC/G
R/
W
EOP
C/G
R/WEOP
C/G
R/WR/WEOPEOP50'11'24'11'2'2'50'11'24'11'2'50'15'20'15'D/W D/W D/W D/WD/W D/W
D/W1'10'1'10'120'0+00BEGIN UG HEREEXISTING CATV PED1+20END UG HEREEXISTING CATV PED10'7'12'10'CATCHBASIN(TYP)SEWERLID(TYP)11'ORCHID ST
W 7
T
H
S
T PROPOSED BORE PLACEMENTFOR 120' ALONGORCHID STAT MIN DEPTH OF 36"USING 2" 13.5 SDR ROLL PIPEWITH 0.700" COAXIAL CABLE6 TH ST W162' ± TO
W 8
T
H
S
T
236'
±
T
O
MAYPORT RT727' ± TO11'C&G 50'R/W
C/LR/W
EOPC/L11'R/W
R/W
0''12''24''36''48''60''72''84''96''108''0''12''24''36''48''60''72''84''96''108''EOP
24'2' C&G
2' C&G
CATV
C&G
EOP
EOP
WATER
SEWER 11'11'10'
SHEET
---- OF XXX OF 64
SHEET
---- OF XXX OF 64
5 OF 6
OF 66 OF 66