Loading...
253 Seminole Rd RESA23-0036 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: SEARS KRISTOFER KANE 253 SEMINOLE RD ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170524 0000 SALTAIR SEC 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 253 SEMINOLE RD RESIDENTIAL ADDITION SINGLE OR TWO FAMILY RESIDENTIAL ADDITION MASTER BATH ADDITION $75000.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. 2 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL Notes: Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 12/5/2023 PERMIT NUMBER RESA23-0036 ISSUED: 12/5/2023 EXPIRES: 6/2/2024 RESIDENTIAL ADDITION PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $380.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $190.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $8.55 STATE DCA SURCHARGE 455-0000-208-0600 0 $5.70 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $784.25 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL Notes: Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of- way for construction parking. 5 PUBLIC WORKS GRASS INFORMATIONAL Notes: Full site to be grassed. 6 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 7 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL Notes: All construction debris must be removed from job site by Owner. 8 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Owner. 2 of 2Issued Date: 12/5/2023 PERMIT NUMBER RESA23-0036 ISSUED: 12/5/2023 EXPIRES: 6/2/2024 RESIDENTIAL ADDITION PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION MASTER BATH ADDITION 253 SEMINOLE RD N/A RESA23-0036 170524 0000 RESA23-0036 RESA23-0036 RESA23-0036 RESA23-0036 c COPYRIGHT 2023 MB ENGINEERING & ITS ASSOCIATES. DESIGNER, EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHT IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHAT SO EVER WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF MB ENGINEERING, OR ITS ASSOCIATES, NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN CONSENT.SHEETDATEJOB #DRAWN BY:N CONCRETE: ALL CONCRETE TO BE DESIGNED AS PER ACI 318 LATEST EDITION. FOOTINGS: 3000psi SLAB ON GRADE: 3000psi ALL OTHERS: 3000psi SPLICES IN REINFORCING WHERE PERMITTED CONCRETE: 50 BAR DIAMETER MASONRY: 48 BAR DIAMETER UNLESS SHOWN ON THESE DRAWINGS, MIN. CONCRETE FOR REINFORCING CAST AGAINST EARTH: 3" SLAB ON GRADE: CENTERED EXPOSED TO EARTH OR WEATHER- #6 THRU #11 BARS: 2" #5 BARS & SMALLER: 1-1/2" ALL REINFORCING SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES IN ACCORDANCE WITH ACI 315 DURING PLACEMENT OF CONCRETE. FLORIDA BUILDING CODE 2020, AMERICAN CONCRETE INSTITUTE, AMERICAN INSTITUTE OF TIMBER CONSTRUCTION CODES: CODE ANALYSIS: *2020 FLORIDA BUILDING CODE - BUILDING (7TH EDITION) *2020 FLORIDA BUILDING CODE - RESIDENTIAL (7TH EDITION) *2020 FLORIDA BUILDING CODE - RESIDENTIAL EXISTING (7TH EDITION) *2020 FLORIDA BUILDING CODE - PLUMBING (7TH EDITION) *2020 FLORIDA BUILDING CODE - MECHANICAL (7TH EDITION) *2017 NATIONAL ELECTRICAL CODE GENERAL STRUCTURAL NOTES: DESIGN CODE: FLORIDA BUILDING CODE 2020 AND ASCE-7-16 ULTIMATE DESIGN WIND SPEED: VULT.: 129 MPH WIND IMPORTANCE FACTOR: I = 1.0 BUILDING RISK CATEGORY: II WIND EXPOSURE: B ENCLOSURE: ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT: GCPI = +.18 OR -.18 WIND PRESSURE TO COMPONENTS/ CLADDINGS (MEAN ROOF HEIGHT 13') END ZONE = 3' ZONE EFFECTIVE WIND AREA(SF) WIND LOADS (PSF) POSITIVE SUCTION INTERIOR 10 +38.1 -41.3 20 +36.4 -39.6 50 +34.2 -37.4 100 +32.5 -35.7 END ZONE 10 +38.1 -50.8 20 +36.4 -47.5 50 +34.2 -43.0 100 +32.5 -39.6 NOTE: AWS DESIGN PRESSURE = ULTIMATE PRESSURE X 0.6 OR DIVIDE WITH 1.6 SCOPE OF WORK: PLANS ARE BASED ON ADDITION OF A 159sf BATHROOM TO AN EXISTING RESIDENTIAL STRUCTURE WIND LOAD NOTES: *A101 - SCOPE OF WORK, SITE PLAN, NOTES & ANALYSIS, ELEVATIONS *A102 - PROPOSED SITE PLAN *A103 - NEW ADDITION: FLOOR PLAN, ROOF FRAMING PLAN, SECTIONS & DETAILS *A104 - ENGINEERING NOTES, FLASHING NOTES LOCATION MAP SCALE - NO SCALE MATERIALS: WOOD MEMBERS FOR BEAMS & POSTS: (#2 SYP) WOOD MEMBERS FOR STUDS: (#2 SYP OR BETTER) MICROLLAM: 1.9E TIMBER: ALL WOOD FRAMING SHALL BE FABRICATED AND INSTALLED AS PER AITC & TPI & NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. PROVIDE TEMPORARY TOP CHORD BRACING UNTIL ROOF SHEATHING IS IN PLACE. ALL WOOD MEMBERS EXPOSED TO WEATHER SHALL BE PRESSURE TREATED. PRE-ENGINEERED WOOD TRUSSES SHALL COMPLY WITH TRUSS PLAT INSTITUTE STANDARD WITH PROPER DEAD, LIVE AND WIND LOADS. DRAWINGS SHALL BE SIGNED AND SEALED BY PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. PROVIDE HURRICANE CLIPS AT BOTH ENDS OF EACH RAFTER & TRUSS. THE NUMBER AND SIZE OF NAILS CONNECTING TO WOOD MEMBERS SHALL NOT BE LESS THAN THOSE SPECIFIED IN FBC 2010 TABLE 2304.9.1 FASTENING SCHEDULE. GENERAL NOTES:1. ALL CONSTRUCTION MUST COMPLY WITH ALL GOVERNING CODES. 2. ALL CONTRACTORS AND SUB-CONTRACTORS WILL THOROUGHLY FAMILIARIZE THEMSELVES WITH THESE CONSTRUCTION DOCUMENTS AND WILL VERIFY EXISTING SITE AND BUILDING CONDITIONS PRIOR TO SUBMITTING A BID. 3. SUB-CONTRACTORS BEFORE STARTING THEIR WORK WILL CHECK AND VERIFY THEIR PARTICULAR RELATED REQUIREMENTS FOR COMPLIANCE ALONG WITH MEASUREMENTS, SURFACE LEVELS, SURFACE CONDITIONS NEAR & ABOUT THEIR WORK. IT WILL BE CONCLUDED THAT EACH BIDDER UNDERSTANDS AND KNOWS WHAT WILL BE REQUIRED. 4. THIS ENGINEER AND HIS PROFESSIONAL CONSULTANTS WILL NOT HAVE CONTROL OF & WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES, OR SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK ON THE PROJECT OR FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUB-CONTRACTOR, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK ON THIS SITE. 5. ALL CONTRACTORS WILL PROVIDE ADEQUATE BRACING AND/OR SHORING TO INSURE STRUCTURAL STABILITY OF THE BUILDING AND ALL RELATED BUILDING COMPONENTS, I.E.: STRUCTURAL WALLS, INTERIOR WALL ASSEMBLIES ETC., DURING THE CONSTRUCTION PHASE OF THIS PROJECT. 6. ALL WORK WILL BE COORDINATED WITH OTHER TRADES IN ORDER TO AVOID INTERFERENCE & PRESERVE MAXIMUM HEADROOM & AVOID OMISSIONS. EACH CONTRACTOR WILL INCLUDE ALL MISCELLANEOUS ITEMS REQUIRED BY CODE AND NEEDS TO COMPLETE THIS WORK. 7. ALL MATERIAL USED WILL BE NEW & BEAR UL LABELS WHERE REQUIRED & MEET NEMA STANDARDS. 8. LAYOUT ALL PARTITIONS BEFORE BEGINNING CONSTRUCTION TO PREVENT ERRORS BY DISCREPANCY. ALL DRYWALL PARTITIONS WILL BE INSTALLED AS NOTED ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS. 9. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING, CUTTING, AND/OR INSTALLING MATERIAL, PRODUCT OR EQUIPMENT. IN THE EVENT OF ANY DISCREPANCIES, CONTACT THE ENGINEER BEFORE PROCEEDING WITH THAT WORK. 10. ALL SUB-CONTRACTORS WILL PROVIDE A CERTIFICATE OF INSURANCE TO THE OWNER PRIOR TO STARTING ANY WORK ON THIS PROJECT. CERTIFICATE OF INSURANCE CAN NOT BE TERMINATED OR CANCELED WITHOUT 10 DAYS PRIOR WRITTEN NOTICE TO THE OWNER. 11. NO SUBSTITUTIONS OF ANY KIND FOR MATERIALS SPECIFIED ON THESE CONSTRUCTION DOCUMENTS IS ALLOWED. NO "EQUIVALENT" SUBSTITUTIONS WILL BE MADE, UNLESS APPROVED IN WRITING BY THE ENGINEER & APPROVED BY THE OWNER DUE TO THE LACK OF AVAILABILITY OF ORIGINAL, U.O.N. IN THESE DOCUMENTS 12. EACH CONTRACTOR IS RESPONSIBLE FOR THE FIRST CLASS WORKMANSHIP & WILL ASSUME ALL RESPONSIBILITY FOR THE CARE AND PROTECTIONS OF HIS OWN WORK & MATERIAL FRO DAMAGE. HE WILL MAKE GOOD ANY DAMAGE TO HIS OWN OR OTHER WORK CAUSED BY HIMSELF OR WORKMAN EMPLOYED BY HIM. 13.EACH CONTRACTOR WILL ABIDE BY LOCAL AREA STANDARDS & RELATED OSHA STANDARDS FOR THE SAFETY OF THEIR EMPLOYEES ON SITE. THIS ENGINEER AND HIS PROFESSIONAL CONSULTANTS WILL BE HELD HARMLESS BY THE: OWNER, GC, AND RELATED AWARDED TRADES, ON THIS PROJECT FOR ACCIDENTS OR INJURIES CAUSED OR ACCRUED ON THIS PROPERTY DURING CONSTRUCTION PHASES OF THIS PROJECT. 14. SHOULD FIRE ALARM & SPRINKLER DRAWINGS BECOME A REQUIREMENT, IT WILL BE THE RESPONSIBILITY OF THE SUB-CONTRACTOR AND TO BE SUBMITTED AS SEPARATE PERMIT ISSUE. SQUARE FOOTAGE INFORMATION: *EXISTING COVERED AREA: 1790sf *NEW (BATH) ADDITION AREA: 159sf *TOTAL NEW COVERAGE: 1949sf WINDO BORNE MAP STRUCTURE HEIGHT & NUMBER OF STORIES: * NO NEW MAX ROOF HEIGHTS IN SCOPE OF WORK* INDEX OF DRAWINGS: PROJECT ANALYSIS FOR ADDITION:LOT COVERAGE INFORMATION: *LOT AREA: 7841sf *NEW COVERAGE: 1949sf *NEW IMPERVIOUS COVERAGE: 25% SCALE - NO SCALE PARCEL MAP SCALE - NO SCALE A10108/02/23WEB2023-193Sears ResidenceAddition to an Existing Residence253 Seminole Rd, Atlantic Bch, Fl, 32233Title Page c COPYRIGHT 2023 MB ENGINEERING & ITS ASSOCIATES. DESIGNER, EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHT IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHAT SO EVER WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF MB ENGINEERING, OR ITS ASSOCIATES, NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN CONSENT.SHEETDATEJOB #DRAWN BY:N NEW ADD A10208/02/23WEB2023-193Sears ResidenceAddition to an Existing Residence253 Seminole Rd, Atlantic Bch, Fl, 32233Site PlanScale - 1" = 15' c COPYRIGHT 2023 MB ENGINEERING & ITS ASSOCIATES. DESIGNER, EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHT IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHAT SO EVER WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF MB ENGINEERING, OR ITS ASSOCIATES, NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN CONSENT.SHEETDATEJOB #DRAWN BY:N1'1'-8"4" CONCRETE SLAB (2) #5 CONT. W/ 30" MIN. LAP BEND AROUND CORNERS USE CHAIRS FOR ROD SUSPENSION WITHIN FOOTERS SCALE: 1/4" = 1' MONOLITHIC FTG.B2B2 Footing & Slab Dowel Detail Scale - No Scale Min. (2) #5 w/ 12" Embedment for Footer Continuation Min. #4 w/ 12" Embedment @ 24" O.C. for Slab Continuation **Note: In all areas where Existing Footings/Slabs are being expanded, Dowel Pins are to be installed per the Dowel Detail. Dowels are to be Epoxy set if installed in any existing cured concrete.** EXISTING EXISTINGEXISTINGEXISTING EXISTING 26682668 EXISTINGEXISTING4010FX2030SH 2030SH 2668EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 2668 3'-7 1/2"6'-4 1/2"4'-8"5'-4 1/2"5'-9 1/2"3'-10"2'1'-7"2'7"15'-10"10' 17'-11" X 23'-0" 12'-6" X 12'-9" 8'-8" X 11'-2" 9'-7" X 9'-5" 8'-0" X 6'-9" 9'-7" X 5'-8" NEW BATH EXISTING BATH EXISTING LIVING/KITCHEN EXISTING BEDROOM EXISTING BEDROOM WIC B2B2 B2B2 FOUNDATION PLAN SCALE - 1/8" = 1' R-38 Insulation 1/2" Drywall 4" Conc. Slab 2x4 PT Bottom Plate 2x4 Framing @ 16" O.C. R-13 Insulation 3/8" Threaded Rod @ 48" O.C. See Footer Details: Pg.A102 2x2 w/metal Drip Edge 2x4 Fascia Cont. 2X12 Rafter @ 24" O.C. Wall Section Detail Scale - 1/4" = 1'Field Frame& MeasureTPO low slope roof system to act as water barrier, use manufacturers evaluated method(s) for installation. 7/16" OSB Sheathing (or equal) w/ 8d Ring Shank nails 6" O.C. Field & 6" O.C. Edge Simpson H2.5A @ Ea. Rafter S1S1 6" From Siding to Finish Grade New Cementituous Lap Siding, Over Moisture Barrier, Over 7/16" OSB Sheathing Nailed @ 6" O.C. Edges & 6" O.C. on Field Overhang to Match Existing FRAMING PLAN SCALE - 1/8" = 1' 2X10 RAFTERS @ 24" O.C. L1L1 SOILS: MINIMUM ALLOWABLE SOIL BEARING CAPACITY = 2500 PSI SUBSURFACE SOIL CONDITIONS WERE NOT AVAILABLE AT THE TIME OF THIS DESIGN. THE OWNER SHALL PROVIDE TO THE CONTRACTOR A REPORT OF THE SUBSURFACE CONDITIONS. SOIL PREPARATIONS NOTED IN AID REPORT SHALL BE FOLLOWED UNLESS MORE STRINGENT DESIGN IS SPECIFIED WITHIN THESE PLANS. THE FILL BELOW THE FOUNDATION SHOULD BE FREE OF DEBRIS, ORGANIC MATERIAL, COHESIVE SOILDS OR ANY OTHER DELETRIOUS MATERIAL. SOIL MUST BE COMPACTED TO 95% MODIFIED PROCTOR MAXIMUM DRY DENSITY FOR A DEPTH OF 2'-0" BELOW THE BOTTOM OF THE FOOTING CONCRETE: CONCRETE AND STEEL REINFORCEMENT SHALL BE IN ACCORDANCE WITH FBC. SLAB & DRIVE 3000 PSI W/ FIBERFASTENINGS: THE "FASTENING SCHEDULE" IN FBC SHALL BE USED UNLESS OTHERWISE IN THESE PLANS. THE DOUBLE TOP PLATE SHALL HAVE A 4' LAP AND SHALL BE FACE-NAILED WITH (8) 12D SINKERS. ROOF SHEATHING AND DIAPHRAM ATTACHMENT: USE 7/16" APA RATED SHEATHING FASTENED W/ 8D NAILS 6" O.C. EDGES, 6" O.C. INTERMEDIATE. GENERAL NOTES 1. CODES USED: 2020 FLORIDA BUILDING CODE SIXTH EDITION, ACI, NDS, APA AND ASCE-7-16. ALL LATEST EDITIONS USED. 2. ALL DESIGN, CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION OVER THE WORK. 3. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO COMMENCING CONSTRUCTION. 4. DETAILS FOUND WITHIN THESE DRAWINGS SHALL BE ASSUMED TO BE TYPICAL DETAILS FOR THIS JOB ONLY. DETAILS SHALL GOVERN CONSTRUCTION FOR THIS JOB UNLESS OTHERWISE NOTED ON THE PLANS. 5. DIMENSIONS ARE SHOWN FOR REFERENCE ONLY. REFER TO ARCHITECTURAL PLANS FOR ALL DIMENSIONS. IF DIMENSIONS CANNOT BE DETERMINED FROM THE ARCHITECTURAL PLANS, CONTACT THE ARCHITECT OF RECORD. 6. SUBSURFACE SOIL CONDITIONS WERE NOT AVAILABLE AT THE TIME OF THIS DESIGN. IT IS RECOMMENDED THAT THE OWNER PROVIDE TO THE CONTRACTOR A REPORT OF THE SUBSURFACE CONDITIONS. SOIL PREPARATIONS NOTED IN SAID REPORT SHALL BE FOLLOWED UNLESS MORE STRINGENT DESIGN IS SPECIFIED WITHIN THESE PLANS. CONNECTOR & CLIP SCHEDULE: -TRUSS/RAFTER TO TOP PLATE/BEAM: H2.5A -HEADERS/BEAMS TO POSTS/GANGED STUDS @ HEEL: (2) MSTA24 -HEADERS/BEAMS TO POSTS/GANGED STUDS @ FACE: HUC -HEADERS/BEAMS TO CRIPPLES: MSTA24 (PER CRIPPLE) -KING STUD PACK TO BOTTOM PLATE: 3/8" THREADED ROD @ EA. SIDE -KING STUD PACK TO FOUNDATION (OPENINGS EXCEEDING 72"): PA51 -KING STUD PACK TO TOP PLATE: SPH6 -POST BASE TO CEMENTITUOUS SURFACE: ABU -WALL CONCENTRIC TENSION FOR UPLIFT: 3/8" THREADED ROD @ 48" O.C. EXISTING 4010FX EXISTING NORTH ELEVATION SCALE - 1/8" = 1' EXISTING CONST.NEW CONSTRUCTION EXISTING 4010FX EXISTING 2030SH EXISTING EXISTING 2030SH EXISTING EAST ELEVATION SCALE - 1/8" = 1' NEW CONSTRUCTION EXISTING CONST.EXISTING CONST. 2030SH EXISTING EXISTING 2030SH EXISTING L1L1 Ledger Detail Scale - 1/4" = 1' (2)1/4"x5" Titen Screw to Existing CMU Wall @: 32" O.C. Max Existing CMU Wall Existing Roof System 2 X R A F T E R LRU ANGLED BUCKET FOR RIDGE TO LEDGER A10308/02/23WEB2023-193Sears ResidenceFloor Plan, Framing Plans,Sections & Details,Engineering NotesAddition to an Existing Residence253 Seminole Rd, Atlantic Bch, Fl, 32233 c COPYRIGHT 2023 MB ENGINEERING & ITS ASSOCIATES. DESIGNER, EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHT IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHAT SO EVER WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF MB ENGINEERING, OR ITS ASSOCIATES, NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN CONSENT.SHEETDATEJOB #DRAWN BY:N CUT WEATHERBARRIER @45°ANGLE MODIFIED "l" CUT INWEATHER BARRIER LINE OF WINDOW OPENING APPROVED WEATHERBARRIER OVER SHEATHINGOVER WD STUD WALL 7" 7" 1 3 5° STEP 1 STEP 2 TEMPORARILY FOLD-UP &SECURE WEATHERBARRIER (OR TUCK FLAPUNDER) @ HEAD FOLD WEATHER BARRIER INAT JAMBS AND SILL 6" TYP. MECHANICALLY FASTENFANNED EDGE (CAP, NAILS,STAPLES) IF REQUIRED BYFLASHING MANUFACTURER INSTALL 9" WIDESELF- ADHERING FLEXIBLEMEMBRANE FLASHING @SILL EXTEND FLASHING UPJAMBS 6" MIN. STEP 3 STEP 4 APPLY 3/8" NOM.CONTINUOUS BEAD OFSEALANT AT JAMBS & HEADOR APPLY TO BACK OFWINDOW NAILING FLANGE INLINE w/ PRE- PUNCHEDHOLES OR SLOTS STEP 5 INSTALL WINDOW PLUMB,LEVEL & SQUARE PERMANUFACTURERS WRITTENINSTRUCTIONS 5" STEP 6 INSTALL 4" WIDESELF- ADHERINGMEMBRANE FLASHINGOVERNAILING FLANGE @JAMBS EXTEND MEMBRANEFLASHING MIN. 1" BELOWSILL FLEXIBLE FLASHING 1"MIN ." STEP 7 INSTALL 4" WIDESELF- ADHERINGMEMBRANE FLASHINGOVERNAILING FLANGE @HEAD 1"MIN ."EXTEND SELF- ADHERINGMEMBRANE FLASHING 1"MIN. BEYOND JAMBFLASHING NOTE: 1.WINDOW INSTALLATION &FLASHING DETAILS ARECONSISTENT WITH ASTM2112METHOD A-1 EXCEPTSELF-ADHERING MEMBRANEFLASHINGS ARE USED. 2.IT IS THE INSTALLATIONCONTRACTOR SRESPONSIBILITY TO VERIFYTHE COMPATIBILITY OF ALLPRODUCTS INCLUDINGWEATHER BARRIER, SEALANT& SELF- ADHERING FLASHINGMATERIALS USED DURINGCONSTRUCTION. 3.INSTALL ALL MATERIALS PERMANUFACTURERS WRITTENSPECIFICATIONS. WARNING: SEALANT/FLASHINGS MAYREACT ADVERSELY IF NOTCOMPATIBLE. STEP 8 STEP 9 INTERIOR VIEW FOLD WEATHER BARRIERDOWN & TAPE DIAGONALCUT & ACROSS HEAD OFWINDOW SEAL WINDOW FRAME TOINSIDE OF R.O. WITHSEALANT AT SILL AND AMINIMUM 12" UP BOTHJAMS TO FORM A BACKDAM. SEAL BALANCE OFFRAME WITH SEALANT ORLOW-EXPANDING FOAM(PROVIDE BACKER RODWHERE REQUIRED)12" MIN. w/SEALANTAPPROVED WEATHERBARRIER OVER WDSHEATHING FOLD WEATHERBARRIER IN ANDAROUND JAMBS CUT WEATHERBARRIE R INSTALL DOOR PLUMB,LEVEL & SQUARE PERMANUFACTURER WRITTENINSTRUCTIONS SET THRESHOLD INBED OF SEALANT APPLY SEALANT ATCORNERS & FRONT EDGEOF THRESHOLD STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 NOTE: AT UNPROTECTED DOORS, BOTTOM1/4th OF JAMBS SHALL BE COMPOSITE, P.T.OR OTHER DECAY RESISTANT MATERIAL INSTALL 4" WIDESELF- ADHERING MEMBRANEFLASHING OVERLAPPINGDOOR FRAME 1/4" INSTALL 4" WIDESELF- ADHERING MEMBRANEFLASHING OVERLAPPINGDOOR FRAME 1/4" EXTEND SELF- ADHERINGMEMBRANE FLASHING 1" MIN.BEYOND JAMB FLASHING SEE DOOR DETAILS FORFINISH/TRIM DETAILS 4" 1/4" 1/4" 1/ 4"1"MI N. WINDOW FLASHING INSTALLATION DETAILS N.T.S. DOOR FLASHING INSTALLATION DETAILS N.T.S. 6 " 6 "6 "1 2 " 1 2 " 6 "S I D E L A P 2 " R O O F D E C K U N D E R L AY M E N T S U C C E E D I N G C O U R S E R A K E D R I P E D G E E N D L A P 6 " E A V E D R I P E D G E UNDER LAYMEN T PLACE SHINGLES 3/8"OVER EAVE & RAKEEDGES TO PROVIDE DRIPEDGEALONG RAKES, CEMENTSHINGLES TO UNDERLAYMENT& EACH OTHER IN A 4" WIDTHOF ASPHALT PLASTIC ROOFCEMENT NON- CORRODINGMTL EAVE DRIPTRIM 6"-7" FROM ENDOF FIRST SHINGLE TRIM TABS FROM ALLSTARTER COURSESHINGLES STARTER COURSE PLACE SHINGLES CLOSETOGETHER BUT DO NOTCROWD ALONG RAKES, CEMENTSHINGLES TO UNDERLAYMENT& EACH OTHER IN A 4" WIDTHOF ASPHALT PLASTIC ROOFCEMENT NON- CORRODINGMTL EAVE DRIP PLACE SHINGLES 3/8"OVER EAVE & RAKEEDGES TO PROVIDE DRIPEDGE FIRST COURSE 11-1/2" to 12-1/2"11-1/2" to 12-1/2" 1" to 1-1/2"1" to 1-1/2"12"6"SHINGLE NAILING ROOFING DETAILS NOTE: DETAILS ARE FOR SLOPES OF 4:12 OR GREATER,FOR SLOPES BELOW 4:12, ALL ROOFING UNDERLAYMENTSHALL BE SELF ADHERING SHEET MEMBRANE APPROVEDBY THE SHINGLE MANUFACTURER FOR USE ON LOWSLOPE ROOFING PROJECTS OPT. PROVIDE LEAD VENTBOOT WITH INTEGRAL FLANGE VENT STACK, SEE PLUMBINGFOR SIZE & LOCATIONPREFORMED FLEXIBLE BOOTFLASHING W/ INTEGRAL FLANGESET IN PLASTIC ROOF CEMENT INSTALL FLANGE OVERSHINGLE @ BASE FIBERGLASS SHINGLEROOFING OVER 15# FELTOVER 7/16" OSB OVERPRE-ENG WD TRUSSES INSTALL SHINGLES OVERFLANGE @ HEAD NOTES: 1.INSTALL IN STRICT ACCORDANCE WITHMANUFACTURERS WRITTEN INSTRUCTIONS 2.APPLY ROOFING CEMENT OR SELF- ADHERINGFLASHING OVER FLANGE AT HEAD ONLY WALL SHEATHING STUCCO/CV FINISHASSEMBLY W/ 15# FELTOVER APPROVED WEATHERBARRIER LAP FELT AND WEATHERBARRIER OVER VINYLSTUCCO STOP/WEEP EXTEND 15# ROOFING FELTUP WALL 7" MIN. 5x5 METAL FLASHING OVERROOFING FELT (NAIL TOROOF DECK NOT WALLSHEATHING) CAP SHINGLE - DO NOT NAILINSTALL WITH ROOFCEMENT SHINGLE ROOFING ROOF CEMENT VENT STACK FLASHING DETAIL N.T.S.7" (MIN.)5" (MIN.)1-1/2" (MIN.)WALL FLASHING DETAIL - STUCCO N.T.S. WALL SHEATHING SYN WD SIDING OVERAPPROVED WEATHERBARRIER LAP WEATHER BARRIER OVERMETAL FLASHING AND SECUREWITH STARTER STRIP EXTEND 15# ROOFING FELTUP WALL 7" MIN. 5x5 METAL FLASHING OVERROOFING FELT (NAIL TO ROOFDECK NOT WALL SHEATHING) CAP SHINGLE - DO NOT NAILINSTALL WITH ROOF CEMENT SHINGLE ROOFING ROOF CEMENT WALL FLASHING DETAIL - LAP SIDING N.T.S.7" (MIN.)5" (MIN.)1-1/2" (MIN.)VALLEY SHINGLE INSTALLATION: INSTALL SHINGLES USING WEAVE METHOD 1.EXTEND (1) FULL END SHINGLE MIN. 12" PASTCENTER LINE OF VALLEY. SEE MANUF WRITTENINSTRUCTION FOR ADDITIONAL INSTALLATIONINFORMATION 2.DO NOT NAIL 6" MIN. FROM VALLEY CENTER LINE 24" WIDE METAL VALLEYFLASHING OVER 15# FELT FIBERGLASS SHINGLEROOFING OVER 15# FELTOVER 7/16" OSB OVERPRE-ENG WD TRUSSES VALLEY FLASHING DETAIL N.T.S. FIBERGLASS SHINGLE ROOFING OVERUNDERLAYMENT INSTALL SHINGLES OVER OFF-RIDGE VENT FLANGE ATHEAD GALVANIZED METAL OFF- RIDGEVENT WITH BAFFLE. SET INPLASTIC ROOF CEMENT ORSEALANT SCREEN INSTALL OFF-RIDGEVENT FLANGE OVERSHINGLES AT BASE 7/16" OSB OVERPRE- ENG WDTRUSSES OFF-RIDGE VENT FLASHING DETAIL N.T.S. STUCCO/CV FINISHASSEMBLY LAP BARRIER OVER NAILINGFLANGE VINYL DRIP/WEEP SCREED 5"x5" METAL FLASHING KICK-OUTFLASHING (SEEDETAIL)2" EXTEND KICK-OUT 2"BEYOND FASCIA FELT UNDERLAYMENT SHINGLE ROOFING MTL DRIP EDGE FASCIA 8" (MIN.)110°5 " (M IN .)5" (MIN.)WATERT IGHTSE AL NOTE: INSTALL KICKOUTFLASHING AT BOTTOM OFROOF & WALL INTERSECTIONS WALL/KICKOUT FLASHING DETAIL N.T.S. N.T.S. NOTES: 1.INSTALL IN STRICT ACCORDANCE WITHMANUFACTURERS WRITTEN INSTRUCTIONS 2.APPLY ROOFING CEMENT OR SELF- ADHERINGFLASHING OVER FLANGE AT HEAD ONLY LINE OF DOOR OPENING EMBED BOTTOM OF THE HEAD FLASHING AGAINST THE PREVIOUSLY APPLIED SEALANT (FLASHING GOES OVER SEALANT). EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. APPLY A CONT. SEAL ALONG MOUNTING FLANGE AT THE HEAD. FLASHING GOES OVER MOUNTING FLANGE. EMBED BOTTOM OF HEAD FLASHING AGAINST SEALANT (FLASHING GOES OVER SEALANT). EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. EXTEND JAMB FLASHING TO OVERLAP SILL FLASHING. EXTEND JAMB FLASHING 8 1/2" ABOVE ROUGH OPENING AT HEAD. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. SEE DIAGRAM. JAMB FLASHING 135 ° 9" 9" CUT LINE 4 5 EXTEND JAMB FLASHING TO OVERLAP SILL FLASHING. EXTEND JAMB FLASHING 8 1/2" (220MM) ABOVE ROUGH OPENING AT HEAD. APPLY TAPE AT CORNERS TO TEMPORARILY HOLD FLASHING IN PLACE UNTIL WRB IS APPLIED. TOP LEFT CORNER OF WINDOW INTERIOR VIEW SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE, PLUMB, AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PER WINDOW MANUFACTURER SPECIFICATIONS. AT A 45 DEGREE ANGLE, CAREFULLY CUT THE BARRIER ON A DIAGONAL. GENTLY RAISE THE TOP EDGE OF THE BARRIER UP AND TAPE THE TOP CORNERS AND CENTER TO THE EXTERIOR WRB SURFACE ABOVE. WEATHER RESISTANT BARRIER (WRB) 1 8 1 SILL FLASHING 9" SEALANT 5 2 5 SEALANT 3 A A3 SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE, PLUMB, AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PER WINDOW MANUFACTURER FASTENER SPECIFICATIONS. 135 ° 9" CUT LINE 9" 1 8 JAMB FLASHING SILL FLASHING 9" 3 2 SEALANT 4 5 A A IN WATER SHEDDING FASHION, STARTING AT THE BASE OF THE WALL & WORKING TOWARDS THE TOP, INSTALL THE WRB TO THE FACE OF THE SHEATHING. REMOVE PREVIOUSLY APPLIED TAPE, ALLOWING WRB TO LAY FLAT OVER HEAD FLASHING. APPLY NEW SHEATHING TAPE OVER DIAGONAL CUT - SEE DIAGRAM. APPLY SILL FLASHING APPLY BEAD OF SEALANT AT BACK OF WINDOW FLANGE & SET WINDOW USING PAN HEAD SCREWS TO FACILITATE INSPECTION. APPLY BEAD OF SEALANT AT SIDE JAMBS. EXTEND 8 1/2" APPLY JAMB FLASHING APPLY BEAD OF SEALANT AT HEAD APPLY HEAD FLASHING WINDOW INSTALLATION (METHOD A-1) STEPS 8 1 /2 " 6 7 5 8 2 3 4 1 WINDOW INSTALLATION (METHOD B-1) WEATHER RESITIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION. FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE. SEALANT BEAD BEHIND MOUNTING FLANGE. JAMB FLASHING APPLY CONT. SEAL TO THE MOUNTING FLANGES AT THE TOP (HEAD) AND SIDES (JAMBS) OF WINDOW. EXTEND SEALANT AT JAMBS 8 1/2" ABOVE THE R.O. AT HEAD. EMBED JAMB FLASHING INTO SEALANT AND FASTEN IN PLACE. (FLASHING GOES OVER SEALANT). 5 8 7 1 8 1 /2 " SEAL THE WINDOW FRAME TO OPENING. APPLY A 3/8" NOM. DIA. TO THE BACKSIDE (INTERIOR) OF THE WINDOW FLANGE, IN LINE WITH ANY PRE-PUNCHED HOLES OR SLOTS.FLASHING SECURE WRB AT HEAD FLASHING AT HEAD EXTENDS 1" BEYOND JAMB FLASHING. HEAD FLASHING7 SEALANT BEAD BETWEEN FLASHING AND MOUNTING FLANGE. 8 THROUGH WINDOW JAMB SECTION A WEATHER RESITIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION. FLASHING APPLIED BEHIND THE MOUNTING FLANGE. THROUGH WINDOW JAMB SEALANT BEAD BETWEEN MOUNTING FLANGE AND FLASHING. WRB SECTION A APPLY SILL FLASHING APPLY JAMB FLASHING APPLY BEAD OF SEALANT AROUND THE PERIMETER OF THE BACK SIDE (INTERIOR SURFACE) OF WINDOW MOUNTING FLANGE. IMMEDIATELY INSTALL WINDOW USING PAN HEAD SCREWS TO FACILITATE INSPECTION. APPLY BEAD OF SEALANT ACROSS THE FACE OF MOUNTING FLANGE AT HEAD APPLY HEAD FLASHINGREMOVE PREVIOUSLY APPLIED TAPE, ALLOWING WRB TO LAY FLAT OVER HEAD FLASHING. APPLY NEW SHEATHING TAPE OVER DIAGONAL CUT - SEE DIAGRAM. 8 SECURE WRB @ HEAD 7 6 8 4 APPLY A 3/8" NOM. DIA. BEAD OF SEALANT TO THE BACKSIDE (INTERIOR) OF THE MOUNTING FLANGE AROUND THE ENTIRE PERIMETER. PLACE BEAD IN LINE WITH ANY PRE-PUNCHED HOLES OR SLOTS. 6 1 3 IN WATER SHEDDING FASHION, STARTING AT THE BASE OF THE WALL & WORKING TOWARDS THE TOP, INSTALL THE WRB TO THE FACE OF THE SHEATHING. 3 2 4 5 1 STEPS FLASHING AT HEAD EXTENDS 1" BEYOND JAMB FLASHING. AFTER INSTALLATION HEAD FLASHING SEAL ALL CORNERS OF MECHANICALLY JOINED FRAMES TO SEAL FRAME SEAM JUNCTURE. 8 1 /2 " 7 FLASHING NOTE: NO W.R.B. REQUIRED @ C.M.U. EXTERIOR NO W.R.B. REQUIRED @ C.M.U. EXTERIOR AT A 45 DEGREE ANGLE, CAREFULLY CUT THE BARRIER ON A DIAGONAL. GENTLY RAISE THE TOP EDGE OF THE BARRIER UP AND TAPE THE TOP CORNERS AND CENTER TO THE EXTERIOR WRB SURFACE ABOVE. WEATHER RESISTANT BARRIER (WRB) 1 NOTE: INTERIOR VIEW TOP LEFT CORNER OF WINDOW A10408/02/23WEB2023-193Sears ResidenceAddition to an Existing Residence253 Seminole Rd, Atlantic Bch, Fl, 32233Flashing Notes & Details