Loading...
1776 Ocean Grove Dr ROOF23-0086 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: MCGOVERN MICHAEL P 1776 OCEAN GROVE DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: EFFECTIVE ROOFING SERVICES LLC 629 PICASSO AVE PONTE VEDRA FL 32081 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169620 0000 OCEAN GROVE UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1776 OCEAN GROVE DR ROOF NON SHINGLE ROOF COATING OVER MOD BIT $9610.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In- Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 12/6/2023 PERMIT NUMBER ROOF23-0086 ISSUED: 12/6/2023 EXPIRES: 6/3/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BLDG 3RD PLAN REVIEW FEE 455-0000-322-1006 0 $75.00 BUILDING PERMIT 455-0000-322-1000 0 $100.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $50.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.13 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.75 TOTAL: $281.88 2 of 2Issued Date: 12/6/2023 PERMIT NUMBER ROOF23-0086 ISSUED: 12/6/2023 EXPIRES: 6/3/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION ROOF COATING OVER MOD BIT 1776 OCEAN GROVE DR EFFECTIVE ROOFING SERVICES LLC ROOF23-0086 3 i=i1r,,,, BUILDING PERMIT APPLICATION FOR INTERNAL OFFICE USE ONLY r 7.5 r, City of Atlantic Beach Building Department PERMIT# 800 Seminole Road, Atlantic Beach, FL 32233 as:° ALL information required to process Phone: (904) 247-5826 Email: Building-Dept@coab.us nJobAddress (73.b OC eon 6,,,0 up o, p_ti 0__,)+.t.0 37, p L 322,33 RE# l tog(02,o- 0000 Legal Description Zb--7A ncj - 75, Zc' E, 07 QCea..,, G,-ot)4, oim'i4 OL S 3- f4- (0-4-7 4. Valuation of Work(Replacement Cost) -//440 Heated/Cooled SF Non-Heated/Cooled SF Class of Work: New Addition Alteration [ tepair Move ['Demo Pool Window/Door Use of existing/proposed structure(s): E Commercial DResidential •If existing structure, is a fire sprinkler system installed?:Yes No Will tree(s)be removed in association with proposed project? Yes (Must submit separate Tree Removal Permit) No Describe in detail the type of work to be performed: t3f Coc f i 0UP A 1,0 E.X/s-(/w2 MO I P1 . 4 ((,•I- ?oolc Florida Product Approval# 0)04, kJ° 2-3-p' -?..-q. b j (For multiple products use Product Approval Information Sheet) Property Owner Information Name Mt c i,,ct.e ( frIE Q bUP y,,v Phone 90 9 j 5._. 57J 3 Address I; OCet-wo DV. city') tate 3i-lr-OUP1 jn ./ c .,ct7s t zip 32 Z. 3Emailf`1_ rncAOV Ob ./1So)'Wner or Agentnt(If Agent, Power of Attorney or Agency Letter Required) Contractor Information/ Name of Company C..Ff ec h. v e j"/ h/, Phone Ck,Li 35 Z-C `t 3 J Address AZA r1C-43. SSO /AU City yt-.Q State ..pL Zip 3ab 3t. Qualifying Agent Lvi5 IN\to e., State Certification/Registration#CCC 1 33 3 457_ Email LV f$. o N c' -' <7 f we c4;0 v-0014i ,40b Site Contact Number TVI - Ths--? _ '4 .11. Worker's Compensation Insurer Aw-k2 v,1 Sa ip..e OR Exempt Expiration Date c-/ fly 1 an Z1-1 Architect's Name Email Phone Engineer's Name Email Phone Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this city/county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE SITE OF THE IMPROVEMENT BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NO E OF COMMENCEMENT. KP ure of Owner or Agent) Signature of Contractor) Signed and sworn to(or affirmed)before me this 30111 day of Signed and sworn to(or affirmed)before me this )1•13od y of Nov may , 2023 by YV1iciu+et P. (hcelDver-& O Nwa)^'be 2,023 by L U I S P'175v‘. ?Cpv; Signature of Notary Signature of Notary Personally Known OR [ 1J-Produced Identification Personally Kn- . O• [ .• oduced Identification Type of Identification: 'IL 01_ Type of Identification: FL. 01- Wss A-. mneCero tia o w Ir!+a w r r Y`• ;•.. VANESSA ANGERSVANESSAANGERS MY COMMISSION#HH 244118MYCOMMISSION#HH 244118 EXPIRES:March 23,2026eEXPIRE d oeg S:March 23,2028 pF.,....- 2-!..., dor. NOTICE OF COMMENCEMENT PREPARE IN DJPLICATE) Permit No. Tax Folio No. State of County of To whom It may concern: The undersigned hereby Informs you that improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. iiiLegaldescriptionofpropertybeingimproved9 Uw OZ • Address of property being imp r v . i kik ALL General description of improvements' roof Owner—_M JUL Address 1772 0 rte—..• S Owner's interest in site of the improvement— Fee Simple Titleholder(if other than owner) Name AddressContractor Address 0l 5...r - u o 7 v R I( Phone N 90'1 e3'S 6q3) Fax No. Surety(if any) — — Address Amount of bond$ Phone No. Fax No. _ Name and address of any person making a loan for the construct on of the improvements. Name Address Phone No._-_ - Fax No. ----- Name of person within the State of Florida,other than himself or herself,designated by owner upon whom notices or other documents may be served: Name— -- Address Phone No. Fax No. In addit or,to himself or herself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statutes. (Fill in at Owner's option). Name ---- Address Phone No. Fax No. vailigangro— Expiration date of Notice of Commencement(the expiration date Is one(1)year from he date of recording unless a different date is specified)' THIS SPACE FOR RECORDER'S USE ONLY l'25QQ11signed. DA7EBeforea his41. 4,4: 01/ 4hreA day2 In the G nn ty of uval,st a or F nda s personal appearedvt iC. - ( N herein by him?self/herself and affirms that ail statements and declarations herein are true and accurate r 1/6 Doc#2023241091,OR BK 20877 Page 1764,11 Number Pages: 1 Recorded 11/21/2023 12:09 PM, I{'9. 4^I`ll" JODY PHILLIPS CLERK CIRCUIT COURT DUVAL Notary Public et Large.State of L County of_t t COUNTY My commission expires:_ 2_02 RECORDING $10.00 Personally Known— or Produced Identification_-—( a wwwr. Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ _______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (Printed name) • Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________) • Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 330 Central Ave. I Clark, NJ 07066 I 800.526.4236 I Fax 732.388.9422 | www.karnakcorp.com Updated: 09.26.22 ROOFING 405 Bond-N-Shield (Base Coat) *Read Safety Data Sheet before using this product.* DESCRIPTION: 405 Bond-N-Shield is a 100% elastomeric acrylic, co-polymer emulsion, specifically designed as a base coating that will provide excellent adhesion to asphalt surfaces. The coating contains stain blockers that prevent asphalt bleed through thus producing a brighter white coating over these surfaces. Technological advances in the KARNAK laboratory also give this acrylic coating improved water blistering resistance in temporary ponding areas versus traditional acrylic coatings. USES: 405 Bond-N-Shield is intended for use as a base coat prior to the application of 501 Elasto- Brite, 505HS Mohave Coat and 529 Renu-White acrylic topcoats, 502 RC-W Elasto-Kote Base or 502 RC-W Elasto-Kote Finish, as well as 670HS Karna-Sil Ultra and 670LS Karna-Sil silicone coatings on built-up roof surfaces that have aged a minimum of 90 days and SBS and APP smooth and granular modified membranes that have weathered 30 days. Meets ASTM D 6083 Type I (For use as a base coat only). SURFACE PREPARATIONS: Surfaces to be coated should be dry, clean, and free of dirt, dust, grease, oil and loose paint. Recommended application temperature is 40°F to 120°F. Power wash surfaces with 799 Wash-N-Prep Roof Cleaner and water. Wash roof surfaces with a minimum of 2000 psi., taking all necessary precautions to avoid damage to the roof system. Patch and repair cracks or holes with 505MS Karna-Flex WB and Resat-Mat or Poly-Mat or appropriate sealants or caulking materials. All wet insulation should be removed and replaced with like materials. New BUR roof surfaces must age a minimum of 90 days before coating. SBS and APP modified bitumen membranes should weather 30 days before coating. APPLICATION: Mix lightly prior to application of the coating. 405 Bond-N-Shield may be applied by brush, spray equipment or roller. For applications in higher temperatures (above 90 °F) KARNAK recommends application in multiple thin coats to prevent trapped moisture problems. Commencement of work by the contractor implies his approval of the deck surface. ROLLER / BRUSH APPLICATION: Apply with a 3/4" – 1-1/4” nap roller or soft roof brush. SPRAY APPLICATION: Utilize a standard paint spray pump or airless spray pump. Equipment manufacturer should be consulted for more complete information. Spray application should be done with a 50% over-spray pattern. COVERAGE RATE: Apply 405 Bond-N-Shield over the surface at the rate of 1.5 gallons per 100 sq. ft. (24 wet mils) over smooth surfaces to 2 gallons per 100 sq. ft. (32 wet mils) over granule surfaces. Allow to dry 6-24 hours then apply the selected finish coating. The total cured mil thickness of 405 Bond-N-Shield and finish coating should be 20 to 24 dry mils. Coverage will vary depending on the surface to be coated. CAUTION: Do not apply when rain is imminent. Protect from freezing. Coating must be dried before exposure to water. Store in a heated room and keep container covered when not in use. Do not thin. Keep out of reach of children. Avoid prolonged contact with skin. Dispose of in an environmentally safe manner. Cover air intakes during application and while drying. For exterior use only. Cold-process systems and coatings, either emulsion or solvent-based, should only be installed on decks with positive drainage. Per NRCA (National Roofing Contractors Association), “The criteria for judging proper slope for drainage is that there be no evidence of standing water on a deck 48 hours after it stops raining.” PACKAGING: Available in 5-gallon pails, 55-gallon drums, and 275-gallon totes. . If further information is needed, contact KARNAK Technical services at 800-526-4236. PHYSICAL PROPERTIES & SPECIFICATIONS Weight per Gallon: 11.4 lbs. Viscosity: 34,000 cps ASTM D2196 Method A Solids by Weight: 65%, Nominal Solids by Volume: 53%, Nominal Color: Light Blue Hardness, Shore A: 60 Elongation: 800%, Nominal ASTM D 2370 Tensile Strength: 249 PSI, Nominal ASTM D2370 Tear Resistance: 83 lbs. force/in. ASTM D 624 Permeability: 3.0 perms Cure Time: 24 to 48 hours@ 77°F and 50% Relative Humidity Application Temp.: 40°F to 120°F. Service Temp (Cured Film): -15°F to 180°F VOC Content: 45 g/L MAX 330 Central Ave. I Clark, NJ 07066 I 800.526.4236 I Fax 732.388.9422 | www.karnakcorp.com Updated: 09.09.21 ROOFING 670HS Karna-Sil Ultra (High Solids, Low VOC Silicone Coating) *Read Safety Data Sheet before using this product.* DESCRIPTION: 670HS Karna-Sil Ultra is a white, single component, high solids, moisture curing silicone coating that produces a durable elastic coating with exceptional weathering and water resistance characteristics. USES: Newly Sprayed Polyurethane Foam or Previously Coated Silicone roofs (no primer required); metal, concrete, masonry, TPO, PVC, Hypalon, and EPDM roofs (requires 180 Karna-Sil Ultra Epoxy Primer); BUR (Built-Up) and Modified Bitumen (requires 180 Karna-Sil Ultra Epoxy Primer or 405 Bond-N-Shield Base Coat). BUR surfaces must be allow to age a minimum of 90 days. SBS and APP granular modified membranes and smooth surface APP membranes must be allowed to weathered a minimum of 30 days as well as new metal roofs. 670HS may be used on vertical as well as horizontal applications. All surfaces must have positive drainage. Note: Vertical application may require multiple coats to achieve desired film thickness. SURFACE PREPARATIONS: Surfaces to be coated should be dry, clean, and free of dirt, dust, grease, oil and loose rust or coating. Recommended application temperature is 50°F to 120°F. Power wash surfaces with 799 Wash-N-Prep Roof Cleaner or 507 SPC Primer/Wash (EPDM Only) and water. Wash roof surfaces with a minimum of 2000 psi. taking all necessary precautions to avoid damage to the roof system. Patch and repair all seams, flashings, damaged areas, leak and cracks with 502MS Karna-Flex, or 505MS Karna-Flex WB or appropriate sealants or caulking materials. APPLICATION: 670HS Karna-Sil Ultra should be applied in a single coat application at the required application rate. If additional coats are to be applied, allow previous coat to cure 2-8 hours (dependent upon temperature and humidity) before applying subsequent coat. Subsequent coats should be applied within 24 hours of previous application to ensure uniform adhesion. Applied coating film should be even and free of pinholes. Coverage will vary depending on the surface to be coated. To improve aesthetics, impact resistance and toughness of the coating, ceramic roofing granules should be applied immediately into the final coat after application. Back-roll granules into coating and allow to cure then blow off or sweep loose granules from the surface. Mix coating prior to application with a 3” diameter mixer (5-gallon pail) or 6” diameter mixer (50 gallon drum). Once product is mixed, the entire container should be used. 670HS Karna-Sil Ultra may be applied by brush, roller or airless spray equipment. Apply at temperatures 50°F to 120°F. Do not apply if rain is expected within 24 hours after application. Commencement of work by the contractor implies their approval of the roof surface. See listing at www.nsf.org for application and cure instructions for rainwater catchment use. ROLLER / BRUSH APPLICATION: Apply with a 3/4" – 1-1/4” nap roller or soft roof brush. SPRAY APPLICATION: For spray application, a high-pressure airless spray unit with a minimum of 3500 psi working pressure at the gun tip should be used. The pump must have a 3 gallon per minute output. Hoses should be jacketed for prevention of moisture contamination. Hoses should have a 3/4” ID and tip size should be a minimum size 0.027 orifice. Do not use with hoses that have been used to spray acrylic coatings. COVERAGE RATE: Apply in a single coat at 1.5 gallons per 100 sq. ft. (24 wet mils) for most applications. COLORS: White CAUTION: Follow SDS and all recommended safety procedures strictly when using these products. If spraying, equipment should be grounded to avoid accidental ignition due to static sparks. Avoid breathing solvent vapors. Use with appropriate MESA/NIOSH approved respirator when exposure can exceed recommended PEL. Not for interior use. Do not apply when rain is imminent. Keep containers properly sealed when stored indoors, in a cool well-ventilated area. Keep containers away from moisture. Keep away from heat, sparks and open flame. Do not store above 100°F. Do not thin. Keep out of reach of children. Avoid prolonged contact with skin. Dispose of in an environmentally safe manner. Cover air intakes during application and while drying. For exterior use only. PHYSICAL PROPERTIES & SPECIFICATIONS Meets ASTM D6694 Weight per Gallon: 10.7 lbs. Solids by Weight: 96%, Nominal Solids by Volume: 96%, Nominal Color: White Hardness, Shore A: 50 Elongation: 192% @ 73° Nominal 216% @ 0°F Nominal ASTM D 2370 Tensile Strength: 331 PSI @ 73° Nominal 432 PSI @ 0° Nominal ASTM D2370 Tear Resistance: 26 PSI ASTM D 624 Cure Time: 2 hrs. @ 95°F / 90% RH 8 hrs. @ 50°F / 20% RH Application Temp.: 50°F to 120°F Service Temp (Cured Film): -15°F to 180°F VOC Content: <50 g/L MAX ASTM D 6694 Solar Reflectance: 0.87 Initial (White Only) 0.70 3-Yr. Aged Thermal Emittance: 0.89 Initial (White Only) 0.90 3-Yr. Aged SRI: 110 Initial (White Only) 86 3-Yr. Age 330 Central Ave. I Clark, NJ 07066 I 800.526.4236 I Fax 732.388.9422 | www.karnakcorp.com Updated: 09.09.21 ROOFING 670HS Karna-Sil Ultra (High Solids, Low VOC Silicone Coating) Cold-process systems and coatings, either emulsion or solvent-based, should only be installed on decks with positive drainage. Per NRCA (National Roofing Contractors Association), “The criteria for judging proper slope for drainage is that there be no evidence of standing water on a deck 48 hours after it stops raining.” PACKAGING: Available in 5-gallon pails and 55-gallon drums. If further information is needed, contact KARNAK Technical services at 800-526-4236.