Loading...
251 LEVY RD COMM23-0060 ARCHITECTURAL PLAN FIRE APPROVALSITE / VICINITY PLANOCCUPANCY TYPE:ADDRESS: 251 LEVY ROAD #108JAX BEACH, FLORIDA.ZONING: ILWIND LOAD: EXPOSURE BGROSS AREA: APPROX. 1908 SQ FTPROPERTY SUMMARYEXISTING BLDG CODE 2020 7TH EDITIONNFPA 101 7.10.1.3 EXIT DOOR TACTILE SIGNAGE NFPA 101 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES0102NFPA 101 7.2.1.7 PANIC HARDWARE & FIRE EXIT HARDWARE0369A 60.0081 NOTICE FOR STRUCTURES WITH LIGHT FRAME TRUSS-TYPE CONSTRUCTION04A-2 LIFE SAFETY PLAN AND GEN NOTESA-1 COVER SHEET AND NOTESLEGENDFIRE MARSHALL NOTESAPPLICABLE CODES:BUILDING CODE SUMMARYFLORIDA BUILDING CODE 2020 7TH EDITIONSCOPE OF WORK: TENANT BUILD OUT1. EXISTING FLOOR / LIFE SAFETY PLAN 2. EXISTING WAREHOUSE BUILDING3. MECHANICAL WORK IS REQUIRED APPLICABLE CODES:FLORIDA BUILDING CODE ( MECHANICAL )2020 7TH EDITIONAPPLICABLE CODES:FLORIDA BUILDING CODE ( ELECTRICAL ) 2020 7TH EDITIONAPPLICABLE CODES:FLORIDA BUILDING CODE ( EXISTING) 2020 7TH EDITIONBUSINESS : LEVY ROAD4. ELECTRICAL WORK IS REQUIRED OCCUPANCY LOAD: 08 MAXMAYPORT ROAD Proposed Tenant Build Out Atlantic Beach, FL.32233 Critical Fuel Services 251 Levy Road #108A-108/2023SOLA-3 PARTIAL FLOOR PLAN AND GEN NOTESA-4 ELECTRICAL AND GEN NOTESA-5 MECHANICAL AND GEN NOTES A-2SOL EXISTING 1 HOUR DEMISING WALL TO REMAIN Life Safety Plan SCALE 1/4" = 1'-0" ToiletExistg ADAOCCUPIED SPACE FOR OCCUPANCY CALCULATIONNTSOFFICE #2OFFICE #1OFFICE #3AREA Electrical Motors ,Metal Parts & Construction SupplyUN OBSTRUCTED PATHWAY EXISTING 1 HOUR UN CONDITIONED SPACE AREA: 1220 SQ FT CONDITIONED SPACE: AREA 688 SQ FTEXITENTRYEXISTGEXISTG OVERHEAD GARAGE DOOR EXITOCCUPANCY TABLE PER NFPA 101SPACE/ ROOM NUMBERTABULATIONRESTROOM N/ABUSINESS OFFICE USE1908(PER TABLULATION) TOTAL= 08 MAX.FIRE :CODE SUMMARY APPLICABLE CODES:BUILDING CODE SUMMARYFLORIDA BUILDING CODE 2020 7TH EDITIONAPPLICABLE FIRE CODES: FLORIDA FIRE PREVENTIVE CODE ON NFPAFLORIDA CODE 2020 7TH EDITION & NFPA 101 LIFE SAFETY CODE RESTROOM SIGNAGE SHALL COMPLY WITH FBC ACC 216.4, 703.1, 703.2 AND 703.5* OCCUPANCY TYPE. SUB CLASSIFICATION* BUILDING CONSTRUCTION TYPE * GROSS SQUARE FOOTAGE: APPROXIMATE. * NUMBER OF STORIES: * BUILDING HEIGHT: APPROXIMATE * INTERIOR WALL FINISH & CEILING FINISHES: * ALLOWABLE COMMON PATH OF TRAVEL LIMIT: * ANY FIRE PROTECTION SYSTEM: 2020 EDITION FLORIDA FIRE PREVENTIVE CODE, BASED ON NFPA 101 TO BEST KNOWLEDGE, PROJECT COMPLIES WITH 2020 EDITION IL1 STORY15 FEETA,B, OR C75ABC FIRE EXTINGUISHERS* INTERIOR WALL FINISH & CEILING FINISHES: A, B OR C FLAME SPREAD 26-75 SMOKE DEVELOPMENTS 0-450* ZONINGINDUSTRIAL LIGHTBUILDING OCCUPANCY LOAD* DEAD END LIMIT: 50* TRAVEL DISTANCE LIMIT: 150BUILDING -SPRINKLERED (Y) (N)NGROSS AREA08 OCCUPANTSApprox 1908Approx. 1220/ 300BACKROOM- Noncombustilbe parts04 OCCUPANTS BUSINESS OFFICE ( heat and cool)04 OCCUPANTS LEGENDApprox. 632/ 150HARDWARE SCHEDULEDOOR HARDWARE PER FBC 11-4.4.13.9ALL DOOR HARDWARE, PULL, HANDLES, LATCHES, LOCKS AND OTHER OPERATINGDEVICES ON ACCESSIBLE DOORS SHALL BE GRABSABLE AND DOES NOT REQUIRETIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED NOMARK0113NO3'-0" x 7'-0" x 1 3/4"SIZEMATERIALFRAMERATINGSTANDARD* TO HAVE LEVER TYPE HANDLES PER ADA.REMARKHALLOW METAL3'-0" x 7'-0" x 1 3/4"02HIGHER THAN 48 INCHES ABOVE FINISH FLOOR.2-3'-0" X 3'-0"X 1 3/4"A45 MIN.SOLID COREWOODPER IFC TABLE 3206.2 AREA UNDER 2,500 : SPRINKLER NOT REQUIRED DEMISING WALL TO REMAINApprox. 56 Sq Ft.Storage in other than storage and mercantile occupancies01010102AAHALLOW METALHALL/STORAGE DOORHALLOW METALHALLOW METALWAREHOUSE -STORAGEUN CONDITIONED SPACEAREA 1220 SQ FT.THIS O.H DOOR SHALL REMAIN WHEN OCCUPIED BY STAFF FIXED GLASSBUSINRESS OFFICE CONDITIONED SPACEAREA 688 SQ FT.STAFFVACANT UNITOPEN SPACEProposed Tenant Build Out Atlantic Beach, FL.32233 Critical Fuel Services 251 Levy Road #108LOW HAZARD MATERIALS- NON PUBLIC ACCESSIBLEMAXIMUM PILE DIMENSION SHALL BE 100 FEET AND MAXIMUM PERMISABLE HEIGHT UNDER 40 FEETBACKROOM- StorageStorageLEGEND:DENOTES FIRE EXTINGUISHER DENOTES TRAVEL PATHTACTILE EXIT SIGN PER NFPA 101 ( 7.10.1.3 ) & FBC 1006.3.4TACTILE SIGNAGE STATING " EXIT" SHALL BE INSTALLED ADJACENT OF THE LATCH SIDE OF DOOR 60 INCHES ABOVEFINISHED FLOOR TO THE CENTER OF THE SIGN.DENOTES EXIT PATHELECTRICAL PANEL W/ DISCONNECTWITH LED EXIT LIGHT COMBINATIONDENOTES EXIT SIGN DENOTES EMERGENCY EXIT LIGHT FRAME TRUSS-TYPE CONSTRUCTION A-3SOLCeiling Framing Plan SCALE 1/4" = 1'-0"OFFICEOFFICEEXISTING DECKBACKROOMVACANT UNITVACANT UNITA-3 1 A-31Ceiling Framing Plan SCALE 1/4" = 1'-0"Proposed Tenant Build Out Atlantic Beach, FL.32233 Critical Fuel Services 251 Levy Road #108 A-4SOLELECTRICAL DEMAND NOTESReceptacle Plan ALL EXISTING RECEPTACLES AT BACKROOMSTORAGE SHALL REMAIN AS ITSOFFICE #2OFFICE #1OFFICE #3BREAKLighting Plan ALREADY BUILT OUTALL EXISTING LIGHTING AT BACKROOMSTORAGE SHALL REMAIN AS ITSBACKROOMSCALE 1/4" = 1'-0"SCALE 1/4" = 1'-0"BACKROOMELECTRICAL LEGENDProposed Tenant Build Out Atlantic Beach, FL.32233 Critical Fuel Services 251 Levy Road #108 1/2" GYP SHEETING" HARD CEILING" A-5SOLMechanical Plan SCALE 1/4" = 1'-0"BACKROOMAHU8" O 12" O10" ORNPlumbing Plan SCALE 1/4" = 1'-0"NOTEPartial Layout PlanAND DRAIN /SEWER LINE EXISTING COLD & HOT WATERALL NEW LINES TOAT CLOSEST CONNECTIONTIE AND CONNECTHot/ Cold , Vent Lines Proposed Tenant Build Out Atlantic Beach, FL.32233 Critical Fuel Services 251 Levy Road #108 SYRNSYSYSYSYSYSY8" O8" O 8" O 8" O 8" O SY4" O8" O8" O10" OSY