Loading...
1799 ATLANTIC BECH DT POOL23-0029 TDH_1ANSl-7 Suction Outlet Safety Compliance Data Sheet (One sheet for each drain or set of drains in the system) Job Name: ___________ _ Address: THIS DATA IS FOR THE: POOL __ AUXILIARY (Spa, Feature(s) etc.) __ SUCTION OUTLET(S) Are there drains: yes__ no __ (if no, go to trunk & return pipe size) Single unblockable __ Two or more __ (if single unblockable, indicate make, model & flow rating then go to trunk & return pipe size) Drain make & model: Listed cover flow rate: _____ gpm SYSTEM FLOW RATE System flow rate: ____ gpm Method of determining system flow: Maximum flow from the pump curve ___ Total dynamic head calculation (attach calculation sheet) ___ Simplified total dynamic head (attach pipe length + filter+ heater resistance) PUMP SELECTION Pump make & model: ___________________ _ (attach pump performance curve, indicating flow as calculated above) PIPE SIZE Branch piping size ___ inch @ 6 fps or lower Trunk line size inch@ 8 fps PIPE SIZE SUMMARY -THIS JOB -PER THE APPLICABLE STANDARD: Suction side filtration branch piping size= ___ .in. per ANSl-15 or 7@ 6 fps Suction side filtration trunk line piping size= in. per ANSl-15 or 7@ 6 fps or 8 fps Return side filtration branch piping size= ___ in. per ANSl-15@ 8 fps Return side filtration trunk line piping size= ___ in. per ANSl-15@ 8 fps Auxiliary drain branch suction line piping size = ___ .in. per ANSl-7 @ 6 fps Auxiliary drain trunk suction line piping size= ___ in. per ANSl-7 @ 8 fps Auxiliary return line piping size = ___ .in. per ANSl-5 @ 10 fps Vacuum line, if installed shall be sized to flow at 8 fps per ANS-5 and shall be covered with a self-closing, self-latching cover per ANSl-7. 1799 AtlanticBeach Dr Atlantic Beach FL 32233 XXX X X NOVA CMP 8" 100 GPM 100GPM XXX Intelliflo VS 3050 100GPM 3" 3" 2" 2" 2" 2" 2"2" 2" POOL23-0029 Chandler Swimming Pool Energy Efficiency Compliance Information NOTE: These Requirements apply ONLY to the Filtration Pump Project Name: Address: Flow Calculations per Standard -Pool water volume ____ + 360 = __ gpm = calculated flow rate. Note: for pools under 13,000 gals. the calculated flow rate or 36 gpm whichever is greater= the filtration flow rate. Is there an Auxiliary load on the filtration pump? Yes __ No __ If so, what is the calculated auxiliary flow rate __ gpm Maximum Flow Rate __ gpm (greater of the filtr~tion flow rate or the auxiliary flow rate if the auxiliary flow is powered by the filtration pump). Minimum suction side filtration pipe size@ 6 fps __ in. Minimum suction side branch pipe size @ 6 fps __ in. Minimum return side filtratioin pipe size@ 8 fps __ in. Minimum return side branch pipe size@ 8 fps __ in. Note: pipe sizing requirements apply ONLY to filtration piping -do not apply to auxiliary load piping. Nominal GPM@ 6 fps 38 63 90 138 185 238 374 540 Nominal GPM@ 8 fps 51 84 119 184 247 317 499 720 Filter type __________ Size ______ _ Minimum Filter Area per filler factor ln the Standard ___ x .375 = ____ gpm (max. flow through filter) Factor= Filter Area x .375 (cartridge) or - x 2.0 (0.E.) or - x 15 (Sand) Backwash valve? Yes __ No __ ( If yes, must be 2 inch minimum) Pump Selection as Listed on (circle one) Curve A (less than 17,000 gal.) or Curve C (greater than 17,000 gal.) Make: ________ Model ______________ _ Flow Rate: __ gpm @ ___ rpm. (flow rate must be<= maximum filtration flow rate) Pump Controls • Filtration pump has no auxiliary load -standard time clock __ Filtration pump with auxiliary load -Control model for low speed default within 24 hr. _________ _ Heater Model ________________ _ Gas Heater efficiency rating _______ (No Pilot Light) Heat Pump efficiency C.O.P. ______ _ Equipment Piping -minimum 4 pipe diameters in front of pump and minimum 18" after filter for future solar. Directional return fittings will be installed. I affirm that the information above is true and correct: _________________ _ Contractor Signature Chandler 1799 Atlantic Beach Dr Atlantic Beach FL 32233 XXX 3610000 100 2"2"2"2" Cartridge 150 150 56.25 XXX Pentair Intelliflo VS 3050 100 3000 XXX Pentair Ultratemp