547 Pelican key RES24-0011 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
MCENTEE THOMAS M 547 PELICAN KEY ATLANTIC BEACH FL 32233-4374
COMPANY:ADDRESS:CITY:STATE:ZIP:
PELLA WINDOW AND
DOOR 4306 Shader Road Ste 100 Orlando FL 32808
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
172027 5580 SELVA LAKES UNIT 02
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
547 PELICAN KEY RESIDENTIAL
WINDOWS/DOORS
Replacing 8 non-impact
windows $11700.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $110.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 BUILDING IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL
Notes:
IN-PROGRESS INSPECTIONS ARE REQUIRED FOR EXTERIOR SIDING, WINDOW, AND DOOR INSPECTIONS, AND SHOULD BE SCHEDULED FOR THE FIRST
DAY OF WORK.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 1/17/2024
PERMIT NUMBER
RES24-0011
ISSUED: 1/17/2024
EXPIRES: 7/15/2024
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
BUILDING PLAN CHECK 455-0000-322-1001 0 $55.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.48
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $169.48
2 of 2Issued Date: 1/17/2024
PERMIT NUMBER
RES24-0011
ISSUED: 1/17/2024
EXPIRES: 7/15/2024
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
Replacing 8 non-impact windows
547 PELICAN KEY
PELLA WINDOW AND DOOR
RES24-0011
RES24-0011
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL16809-R8
Application Type Affirmation
Code Version 2023
Application Status Approved
Comments
Archived
Product Manufacturer Pella Corporation
Address/Phone/Email 102 Main St.
Pella, IA 50219
(641) 621-6096
pellaproductapproval@pella.com
Authorized Signature Joe Hayden Sandi Robinson
pellaproductapproval@pella.com
Technical Representative TROY FARR
Address/Phone/Email 18600 NE WILKES ROAD
PORTLAND, OR 97230
(503) 405-9176
tbfarr@pella.com
Quality Assurance Representative Pat Bortscheller
Address/Phone/Email 102 Main Street
Pella, IA 50219
(641) 621-1000
PJBortscheller@pella.com
Category Windows
Subcategory Horizontal Slider
Compliance Method Certification Mark or Listing
Certification Agency Window and Door Manufacturer Association
Validated By T.E. Lunn, PE, LLC
Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard)Standard
AAMA/WDMA/CSA 101/I.S.2/A440-08
AAMA/WDMA/CSA 101/I.S.2/A440-11
Equivalence of Product Standards
Certified By
I affirm that there are no changes in the new Florida B
which affect my product(s) and my product(s) are in com
new Florida Building Code.
Documentation from approved Evaluation or Validation Entity Yes No N/A
Product Approval Method Method 1 Option A
Date Submitted 07/20/2023
Date Validated 07/20/2023
Date Pending FBC Approval
Date Approved 07/25/2023
Summary of Products
FL #Model, Number or Name Description
16809.1 250 Series Sliding Window 72" x 44" vinyl non-impact XO/OX sliding window
reinforcement
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +35/-35
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16809_R8_C_CAC_CCL 411-H-1463.78-79-80-
Quality Assurance Contract Expiration Date
03/24/2024
Installation Instructions
FL16809_R8_II_Drawing 1869 digitally sealed.pd
Verified By: Warren W. Schaefer P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16809_R8_AE_Drawing 1869 digitally sealed.pd
Created by Independent Third Party: Yes
16809.2 250 Series Sliding Window 72" x 44" vinyl non-impact XO/OX sliding window
meeting stile reinforcements.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16809_R8_C_CAC_CCL 411-H-1463.82.83.pdf
Quality Assurance Contract Expiration Date
03/24/2024
Installation Instructions
FL16809_R8_II_Drawing 1869 digitally sealed.pd
Verified By: Warren W. Schaefer P.E.44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16809_R8_AE_Drawing 1869 digitally sealed.pd
Created by Independent Third Party: Yes
16809.3 250 Series Sliding Window 108" x 44" 1/4 vent vinyl non-impact XOX sliding
lock stile reinforcement.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +35/-35
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16809_R8_C_CAC_CCL 411-H-1463.64.65.pdf
Quality Assurance Contract Expiration Date
06/06/2024
Installation Instructions
FL16809_R8_II_Drawing 1869 digitally sealed.pd
Verified By: Warren W. Schaefer P.E.44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16809_R8_AE_Drawing 1869 digitally sealed.pd
Created by Independent Third Party: Yes
16809.4 250 Series Sliding Window 108" x 44" 1/4 vent vinyl non-impact XOX sliding
lock and meeting stile reinforcements.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16809_R8_C_CAC_CCL 411-H-1463.66.67.pdf
Quality Assurance Contract Expiration Date
06/06/2024
Installation Instructions
FL16809_R8_II_Drawing 1869 digitally sealed.pd
Verified By: Warren W. Schaefer P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16809_R8_AE_Drawing 1869 digitally sealed.pd
Created by Independent Third Party: Yes
16809.5 250 Series Sliding Window 108" x 44" 1/3 vent vinyl non-impact XOX sliding
lock stile reinforcement.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +35/-35
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16809_R8_C_CAC_CCL 411-H-1463.68.69.pdf
Quality Assurance Contract Expiration Date
06/06/2024
Installation Instructions
FL16809_R8_II_Drawing 1869 digitally sealed.pd
Verified By: Warren W. Schaefer P.E.44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16809_R8_AE_Drawing 1869 digitally sealed.pd
Created by Independent Third Party: Yes
16809.6 250 Series Sliding Window 108" x 44" 1/3 vent vinyl non-impact XOX sliding
lock and meeting stile reinforcements.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16809_R8_C_CAC_CCL 411-H-1463.70.71.pdf
Quality Assurance Contract Expiration Date
06/06/2024
Installation Instructions
FL16809_R8_II_Drawing 1869 digitally sealed.pd
Verified By: Warren W. Schaefer P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16809_R8_AE_Drawing 1869 digitally sealed.pd
Created by Independent Third Party: Yes
16809.7 250 Series Sliding Window 52.25" x 62" vinyl non-impact XO/OX sliding wind
and meeting stile reinforcements.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16809_R8_C_CAC_CCL 411-H-1463.58.59.pdf
Quality Assurance Contract Expiration Date
10/12/2025
Installation Instructions
FL16809_R8_II_Drawing 1869 digitally sealed.pd
Verified By: Warren W. Schaefer, P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16809_R8_AE_Drawing 1869 digitally sealed.pd
Created by Independent Third Party: Yes
16809.8 250 Series Sliding Window 96" x 62" vinyl non-impact XO/OX sliding window
meeting stile reinforcements.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +30/-30
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16809_R8_C_CAC_CCL 411-H-1463.50.51.pdf
Quality Assurance Contract Expiration Date
10/19/2025
Installation Instructions
FL16809_R8_II_Drawing 1869 digitally sealed.pd
Verified By: Warren W. Schaefer, P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16809_R8_AE_Drawing 1869 digitally sealed.pd
Created by Independent Third Party: Yes
16809.9 250 Series Sliding Window 78" x 84.5" overall size vinyl non-impact XO/OX sl
with integral transom.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +25/-25
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16809_R8_C_CAC_CCL 411-H-1463.84.85.pdf
Quality Assurance Contract Expiration Date
06/29/2024
Installation Instructions
FL16809_R8_II_Drawing 1869 digitally sealed.pd
Verified By: Warren W. Schaefer, P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16809_R8_AE_Drawing 1869 digitally sealed.pd
Created by Independent Third Party: Yes
16809.10 250 Series Sliding Window 120" x 62" vinyl non-impact XOX 1/4 vent sliding
lock and meeting stile reinforcements.
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL16812-R8
Application Type Affirmation
Code Version 2023
Application Status Approved
Comments
Archived
Product Manufacturer Pella Corporation
Address/Phone/Email 102 Main St.
Pella, IA 50219
(641) 621-6096
pellaproductapproval@pella.com
Authorized Signature Joe Hayden Sandi Robinson
pellaproductapproval@pella.com
Technical Representative TROY FARR
Address/Phone/Email 18600 NE WILKES ROAD
PORTLAND, OR 97230
(503) 405-9176
tbfarr@pella.com
Quality Assurance Representative Pat Bortscheller
Address/Phone/Email 102 Main Street
Pella, IA 50219
(641) 621-1000
PJBortscheller@pella.com
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency Window and Door Manufacturer Association
Validated By T.E. Lunn, PE, LLC
Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard)Standard
AAMA/WDMA/CSA 101/I.S.2/A440-08
AAMA/WDMA/CSA 101/I.S.2/A440-11
AAMA/WDMA/CSA 101/I.S.2/A440-17
Equivalence of Product Standards
Certified By
I affirm that there are no changes in the new Florida B
which affect my product(s) and my product(s) are in com
new Florida Building Code.
Documentation from approved Evaluation or Validation Entity Yes No N/A
Product Approval Method Method 1 Option A
Date Submitted 07/20/2023
Date Validated 07/20/2023
Date Pending FBC Approval
Date Approved 07/25/2023
Summary of Products
FL #Model, Number or Name Description
16812.1 250 Series Single Hung Window 36" x 63" vinyl non-impact single window
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +35/-35
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16812_R8_C_CAC_CCL 411-H-1462.51.52.pdf
Quality Assurance Contract Expiration Date
06/13/2024
Installation Instructions
FL16812_R8_II_Drawing 1867 digitally sealed.pd
Verified By: Warren W. Schaefer P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16812_R8_AE_Drawing 1867 digitally sealed.pd
Created by Independent Third Party: Yes
16812.2 250 Series Single Hung Window 48" x 84" vinyl non-impact single window with full
stiles & rails
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +35/-35
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16812_R8_C_CAC_CCL 411-H-1462.45.46.pdf
Quality Assurance Contract Expiration Date
06/13/2024
Installation Instructions
FL16812_R8_II_Drawing 1867 digitally sealed.pd
Verified By: Warren W. Schaefer P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16812_R8_AE_Drawing 1867 digitally sealed.pd
Created by Independent Third Party: Yes
16812.3 250 Series Single Hung Window 54" x 66" vinyl non-impact single window with full
stiles & rails & HP package
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16812_R8_C_CAC_CCL 411-H-1462.53.54.pdf
Quality Assurance Contract Expiration Date
06/13/2024
Installation Instructions
FL16812_R8_II_Drawing 1867 digitally sealed.pd
Verified By: Warren W. Schaefer P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16812_R8_AE_Drawing 1867 digitally sealed.pd
Created by Independent Third Party: Yes
16812.4 250 Series Single Hung Window 48" x 72" vinyl non-impact single window with full
stiles & rails & HP package
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Configurations of glass shall conform to the current ASTM
E1300 standard.
Certification Agency Certificate
FL16812_R8_C_CAC_CCL 411-H-1462.55.56.pdf
Quality Assurance Contract Expiration Date
06/13/2024
Installation Instructions
FL16812_R8_II_Drawing 1867 digitally sealed.pd
Verified By: Warren W. Schaefer P.E. 44135
Created by Independent Third Party: Yes
Evaluation Reports
FL16812_R8_AE_Drawing 1867 digitally sealed.pd
Created by Independent Third Party: Yes
411-H-1462.51 Pella® 250 Series or Power Symphony® or CWS®
Comfort Shield Single Hung
101/I.S.2/A440-11 Class R-PG35; Size Tested
1016mm x 1600mm (40in x
63in) Type-H; DP +35/-35 psf;
Water Test Press 330Pa
(6.89psf); Can. Air Infil/Exfil.
Level=A2
1016mm 1600mm C9414.01-501-47 4/10/2020 6/13/2024
411-H-1462.52 Pella® 250 Series or Power Symphony® or CWS®
Comfort Shield Single Hung
101/I.S.2/A440-08 Class R-PG35; Size Tested
1016mm x 1600mm (40in x
63in) Type-H; DP +35/-35 psf;
Water Test Press 330Pa
(6.89psf); Can. Air Infil/Exfil.
Level=A2
1016mm 1600mm C9414.01-501-47 4/10/2020 6/29/2024
By:
Program Administrator:
Administrative Management Systems, Inc.
PO Box 730, 205 West Main
Sackets Harbor, NY 13685
TEL (315)646-2234 staff@amscert.com
WDMA and AMS HEREBY CERTIFY that the aforesaid Company ("Licensee"),
at its participating manufacturing plant(s), is licensed to use the WDMA
Registered Hallmark on product lines that have been manufactured in
accordance with the indicated standards. It is further certified that the plant(s),
facilities, quality control procedures, methods, and processes of Licensee have
been inspected, and are subject to regular follow-up inspection and test. It is
further certified that samples of the product set forth above were tested and
found to comply with the standards.
Program Sponsor:
Window and Door Manufacturers Assoc
330 N. Wabash Avenue, Suite 2000
Chicago, IL 60611
TEL (312)673-4828 www.wdma.com
By:
Hallmark® Certificate of
Mfr ID:
TEL:
411
641-621-6096
Product No. Product Name Standard Rating Wide High Test Report # CertDate ExpDate
Pella Corporation
102 Main Street
Pella, IA 50219
Conformance and License (CCL)
For more Information visit www.amscert.com
Website:www.pella.com
WD-20 5/26/2016 JGK Page 1Friday, March 3, 2023
Digitally signed by Warren W Schaefer Date: 2023.03.09 09:33:17 -05'00'