Loading...
1545 MAIN ST ROW23-0007 VERIZON Construction Drawings.VERIZON: NEW SITE BUILDVERIZON WIRELESS SITE NUMBER:VERIZON WIRELESS SITE NAME:SITE TYPE:TOWER HEIGHT:BUSINESS UNIT #:SITE ADDRESS:COUNTY:JURISDICTION:578574MAYPORT ASELF SUPPORT TOWER192'-6"812565DUVALCITY OF ATLANTICBEACH1545 MAIN STREETATLANTIC BEACH, FL 32233LOCATION MAPNO SCALESITE INFORMATIONCARRIER/APPLICANT:SHEET #DRAWING INDEXSHEET DESCRIPTIONJEA----ELECTRIC PROVIDER:AT&T----TELCO PROVIDER:GROUND ELEVATION:30° 20' 13.00"-81° 25' 12.00"UFACILITY IS UNMANNED AND NOT FORHUMAN HABITATIONOCCUPANCY CLASSIFICATION:A.D.A. COMPLIANCE:MAP/PARCEL #:CITY OF ATLANTIC BEACHJURISDICTION:172325-0010MAYPORTDUVALAREA OF CONSTRUCTION: EXISTINGNAD83PROPERTY OWNER:CROWN CASTLE6420 CONGRESS AVENUE, STE 2000BOCA RATON, FL 33487TOWER OWNER:IIBTYPE OF CONSTRUCTION:12 FT.1545 MAIN STREETATLANTIC BEACH, FL 32233PAR PRO LTDPO BOX 330177ATLANTIC BEACH, FL 32233CROWN CASTLE USA INC.SITE NAME:LAT/LONG TYPE:LONGITUDE:LATITUDE:CURRENT ZONING:COUNTY:SITE ADDRESS:CALL FLORIDA ONE CALL(800) 432-4770CALL 3 WORKING DAYSBEFORE YOU DIG!PROJECT TEAMA&E FIRM:CROWN CASTLEUSA INC. DISTRICTCONTACTS:TOWERSOURCE, INC.1355 WINDWARD CONCOURSESUITE 410ALPHARETTA, GA 30005TITLE SHEETT-1SITE PLANC-1.1C-1.2C-2C-3PROPOSED EQUIPMENT PLANFINAL ANTENNA & CABLE CONFIGURATIONANTENNA LAYOUT & TOWER ELEVATIONGENERAL NOTEST-2KEVIN JONES - CONSTRUCTION MANAGER6420 CONGRESS AVE SUITE 2000BOCA RATON, FL 33487VERIZON WIRELESS7701 TELECOM PARKWAYTEMPLE TERRACE, FL 33637ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17.CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS ANDCONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THEENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITHTHE WORK OR BE RESPONSIBLE FOR SAME.PROJECT DESCRIPTIONSTRUCTURAL ANALYSIS:DATED:APPLICABLE CODES/REFERENCEDOCUMENTSMORRISON HERSHFIELD10/10/2022REFERENCE DOCUMENTS:MOUNT ANALYSIS:DATED:ORDER ID:REVISION:6300602RFDS REVISION:DATED:----09/27/2022C-4EQUIPMENT SPECSC-5 SITE DETAILSG-1.1G-2PROPOSED UTILITY ROUTINGPROPOSED GROUNDING PLAN01.0CREST HEIGHT:V = 129 MPH (ULTIMATE 3 SECOND GUST)NAANALYSIS CRITERIA:WIND SPEED:SEISMIC RESPONSE:CEXPOSURE CATEGORY:IIRISK CATEGORY:1TOPOGRAPHIC CATEGORY:K=ZTTIA-222-H / ASCE 7-16APPLICABLE CODES:NOTE:PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWNNOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER.SITE ID:578574LAT: 30° 20' 13.00"LONG: -81° 25' 12.00"THE PURPOSE OF THIS PROJECT IS TO ENHANCEBROADBAND CONNECTIVITY AND CAPACITY TO THEEXISTING ELIGIBLE WIRELESS FACILITY.TOWER SCOPE OF WORK:·INSTALL (9) ANTENNAS·INSTALL (3) OVPs·INSTALL (9) RRHs·INSTALL (3) 1-5/8" HYBRID CABLES·INSTALL (3) VFA12-HD SECTOR ANTENNA MOUNTGROUND SCOPE OF WORK:·INSTALL (1) 4' x 10' CONCRETE EQUIPMENT PAD·INSTALL (1) 4' x 10' CONCRETE PAD FOR LP TANK·INSTALL (1) 4' x 10' CONCRETE GENERATOR PAD·INSTALL (1) EQUIPMENT H-FRAMEG-3 PANEL SCHEDULE & ONE-LINE DIAGRAMALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCEWITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THELOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BECONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES:CODE TYPECODEBUILDING 2020 FLORIDA BUILDING CODE 7TH EDITION/2015 IBCMECHANICAL 2020 FLORIDA BUILDING CODE 7TH EDITION/2015 IMCELECTRICAL 2020 FLORIDA BUILDING CODE 7TH EDITION/2017 NECIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0T-1REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #31572PETER VERDECCHIA - PROJECT MANAGERPETER.VERDECCHIA@CROWNCASTLE.COMverizonGENERATOR SPECSG-4ELECTRICAL & GROUNDING DETAILSC-6C-7C-8C-9SITE DETAILSSITE DETAILSSITE DETAILSG-5 ELECTRICAL & GROUNDING DETAILSC-10 PROPANE TANK DETAILSG-1.2 FUEL LINE DIAGRAMC-4.1EQUIPMENT SPECS11/29/2022javad k parsaDigitally signed by javad k parsa Date: 2022.11.29 10:07:35 -05'00'By Toni Gindlesperger at 3:48 pm, Mar 15, 2023 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0T-2REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-1.1REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-1.2REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-2REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-3REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-4REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-4.1REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #31572ERICSSON11/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-5REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #31572LEGEND1. PRIMARY CABINET2. (NOT USED)3. (NOT USED)4. OVP-12 (PROPOSED AND FUTURE AS NEEDED)5. RADIO MOUNTING AREA. FOLLOW OEM SPECS.6. ILC CABINET (WITH CAMLOCK IF NEEDED)7. DARK FIBER JUNCTION BOX (RESERVE SPACE FORTELCO CABINET IF NECESSARY)8. METER & DISCONNECT (UNLESS METER IS LOCATED ATA CENTRAL METER BANK/RACK)9. RESERVED SPACE FOR CHARLES TELCO CABINETELEVATION VIEW - FRONTELEVATION VIEW - REARNOTE:1. WHEN H-FRAME IS INSTALLED ADJACENT TO CABINET PAD,INTERCONNECTING CONDUITS SHALL BE INSTALLED AT ORABOVE GRADE.FUTUREFUTURENOTE:EACH CABINET SIZE ON THE DRAWINGS HAVING RANGES OF30”- 36”W X 72”- 84”H X 39”- 46”D (WITH COOLING SYSTEM)24" ICE BRIDGE / GRIP STRUT ABOVE(INITIALLY ABOVE OVP ONLY, INSTALL OVERILC AS NEEDED)MAINTAIN 15" (MIN.)CLEARANCE ABOVE RADIOSDUAL FIXTURE LED LIGHT WITH 60 MINUTETIMER (VERIFY WITH LOCAL CX MANAGER)RADIO MOUNTING AREA,FOLLOW OEM SPECS1-5/8" UNISTRUT (TYP.). INSTALL AS NEEDEDFOR RRU MOUNT BRACKETS PRIOR TOINSTALLING ADDITIONAL EQUIPMENT.METER & DISCONNECTSWITCH (AS REQUIRED)FRAME SUPPORT PIPE, ADJUST PIPEDIAMETER AND DEPTH AS NECESSARYFOR LOCAL CONDITIONS (SOIL TYPE,SEISMIC ZONE, ETC.) (TYP.)4000 PSI FIBERMESH CONCRETE PIER,ADJUST PIER DIAMETER AND DEPTH ASNECESSARY FOR LOCAL CONDITIONS (SOILTYPE, SEISMIC ZONE, ETC.) (TYP.)6" THK. (MIN) CONCRETE SLAB4000 PSI FIBERMESH CONCRETE, ADJUSTTHICKNESS AND DESIGN IF NECESSARY FORLOCAL CONDITIONS (REINFORCEMENT, SOILTYPE, SEISMIC ZONE, ETC.) (TYP)NOTE:1. USE 3" CONDUITS BETWEEN CABINET FRAMES.2. ALL CONDUIT TO/FROM ANY BATTERY CABINETMUST BE SEALED TO PREVENT BATTERY GASPENETRATION INTO ADJACENT CABINETS.MAINTAIN 15" (MIN)CLEARANCE ABOVE RADIOSNOTE:1. USE 3" CONDUITS BETWEEN CABINET FRAMES.2. ALL CONDUIT TO/FROM ANY BATTERY CABINETMUST BE SEALED TO PREVENT BATTERY GASPENETRATION INTO ADJACENT CABINETS.RESERVE SPACE FORTELCO CABINET IF NECESSARY11/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-6REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #31572INCOMINGPOWERSERVICE#6 GROUND WIRE BONDED TO ANMGN(EXCEPT IN CA) OR UFER GROUNDTERMINATED TO A GROUNDING BUS BARGROUND DEMARCO BOX PERMANUFACTURER REQUIREMENTPROPOSED TELCO CONDUITFROM INCOMING TELCO FIBERFROM UTILITY DEMARC (TYP.)PROPOSED TELCO 1-1/4" SEALTIGHT CONDUIT (TYP.)PROPOSED FIBER FEED 1-1/4"SEAL TIGHT CONDUIT (TYP.)1-1/4" SEAL TIGHT CONDUITFROM PRIMARY CABINET TOCIENA. LEAVE MALE COUPLERFOR TERMINATION BY OTHERSPOWER CONDUITS FROMDISCONNECT SWITCH TO ATSPROPOSEDDISCONNECTPROPOSEDMETERPROPOSEDGROUND (TYP)(2) 5AMP, 48V DROPS TOPRIMARY CABINETGROUND PRIMARY CABINET PERMANUFACTURER REQUIREMENT(3) #3/0 AWG, (1)#6 AWG EG IN1-1/2"C (185 LF MAX)11/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-7REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #31572#6 AWG GROUNDWIRE TO CADWELDGPSANTENNA (TYP.)PROPOSEDHYBRID CABLES (TYP.)TO TOWERPROPOSEDICE BRIDGE POST (TYP.)4000 PSI WELDED WIRE FABRIC4 X 4-W10.0 X W10.0 PIER. (TYP.)USE BAND AND BUTTERFLYCONNECTION TO SECURE GPSCABLE AND GROUND WIRE TOICE BRIDGE POST AS REQUIREDUNIVERSAL PIPEADAPTER KITGPS ANTENNACOAX GROUND KITPROPOSEDOVP BOXPROPOSED 2' WIDE VERIZONICE BRIDGE CHANNELPROPOSED HYBRID DC /FIBER CABLES (TYP.)HORSE HEAD BRACKET BYVALMONT, MTS OR APPROVEDEQUAL ATTACHED WITH 1/2"U-BOLTMICROFLECT SNAP-INCOAX HANGER (TYP.)MICROFLECT TRAPEZESUPPORT KIT (#B1889)#B1560 FOR 7/8" COAX#B1562 FOR 1-5/8" COAX#B1914 FOR 2-1/4" COAX11/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-8REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #315722" MIN. (TYP.)SECTION VIEWSLUMP - 4" MIN. / 6" MAX.AIR ENTRAINMENT - 2% TO 3% BY VOLUMECLASSES OF CONCRETEREINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES FOR REBAR SHALL BE CLASS "B" AND ALL HOOKS SHALL BE STANDARD, UNO. LAPS FOR WELDED WIRE FABRIC SHALL BE AT LEAST 8 INCHES, UNO.THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST EARTH CONCRETE EXPOSED TO EARTH OR WEATHER #6 AND LARGER #5 AND SMALLER & W.W.F.NOTES4.3.TYPE ICLASS1-1/2"2"3"WATER/CEMENT0.55RATIOMAXPLACEMENTLOCATIONPRECAST2.1.NORMAL WEIGHT(PSI)300028 DAYSTRENGTHPRECAST CONCRETE FOR SLABS SHALL HAVE A MINIMUM COMPRESSIVESTRENGTH OF 3000 PSI AT 28 DAYS. CONCRETE TESTING IS NOT REQUIREDUNLESS NOTED OTHERWISE OR REQUIRED BY THE JURISDICTION HAVINGAUTHORITY.SLABSTYPE III0.45SITE CAST SLABS HIGH EARLY5000& POST FOOTINGS STRENGTHIF REQUIRED BY THE CONSTRUCTION SCHEDULE THE CONTRACTOR MAYSUBSTITUTE TYPE III HIGH EARLY STRENGTH CONCRETE WITH THE APPROVAL OFTHE CONSTRUCTION MANAGER.**WELDED WIRE FRAME6X6 - W2.9X2.9 (TYP)6" THICK PRECAST CONCRETE SLABWITH LIGHT BROOM FINISH (TYP)TOP OF SLAB = 9" AGLPROVIDE 3/4" CHAMFER AT ALLEXPOSED EDGES (TYP.)TOP OF GRAVEL = 6" AGLFINISHED GRADE = 0" AGLWELDED WIRE FRAME 6X6 - W2.9X2.9EACH WAY (TYP.)FOUNDATION ASSUMED TO BEAR ONSUBSTANTIALLY CONSOLIDATED SOILWITH A MINIMUM BEARING CAPACITYOF 1000 PSF. VERIFY PRIOR TO PADINSTALLATION (TYP.)MIRAFI 500X GEOFABRICUNDERLAYMENT(OR EQUIVALENT FABRIC) ABOVEFINSIHED GRADE6" THICK #57 STONE6" THICK CONCRETE SLAB(4000 PSI FIBERMESH CONCRETE)4" 45° CHAMFER6" THK. #57 STONETOP OF GRAVEL = 6" AGLFINISH GRADE = 0" AGLMIRAFI 500X GEOFABRICUNDERLAYMENT(OR EQUIVALENT FABRIC) ABOVEFINSIHED GRADEPREPARED SUBGRADE COMPACTEDTO 95% MAXIMUM DRY DENSITY(PER MODIFIED PROCTOR ASTMD1557/AASHTO T180)ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318,ACI 336, ASTM A184, ASTM A185, IBC 2006.OUTLINE OF PROPOSEDGENERATOR. COORDINATEEXACT LOCATION OFGENERATOR WITH CONDUITSTUB-UP PLACEMENTSTUB-UP CONDUITS6" MIN. ABOVE GEN. PADINSTALL 6" X 12"KNOCKOUT FOR CONDUITSABINSTALL 10" X 16" KNOCKOUT FOR HIGH VOLTAGECONDUITS.GENERATOR CONDUIT KNOCKOUTSARE SIZED AND LOCATED TOCORRESPOND WITH A 50 KWGENERAC LP GAS GENERATORCONSULT WITH VERIZON CM IF ADIFFERENT MODEL GENERATOR ISUSED.BINSTALL 8" X 16" KNOCKOUT FOR LOW VOLTAGECONDUITS.11/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-9REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-10REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #315721. MAINTAIN MINIMUM 1'-0" VERTICAL AND 1'-0" HORIZONTAL SEPARATION OF GAS LINE FROMOTHER UTILITIES.2. CONNECTION POINT MAY VARY WITH GENERATOR MANUFACTURER.3. MAINTAIN 3' SERVICE CLEARANCE ON ALL SIDES OF GENERATOR.4. GENERAL CONTRACTOR SHALL ANCHOR GENERATOR BASE4 TO SLAB OR PLATFORM WITHHOLES PROVIDED.5. CONTRACTOR SHALL VERIFY LOCATION OF ALL EQUIPMENT PRIOR TO INSTALLATION.6. CONTRACTOR SHALL COORDINATE INSTALLATION WITH GAS COMPANY & OTHERDISCIPLINES.7. CONTRACTOR SHALL ADHERE TO APPLICABLE STATE & LOCAL CODES.8. COORDINATE LOCATION OF GAS PIPE WITH OTHER UTILITIES.9. FLEXIBLE CONNECTION TO BE SAME SIZE AS PIPING TIE-IN THAT IS PROVIDED BY THEGENERATOR SUPPLIER.10. CONTRACTOR TO VERIFY GAS PRESSURE PER NOTE ON "GAS PIPE SIZING SCHEDULE".11. GENERATOR TO BE LOCATED A SUITABLE DISTANCE FROM ANY ROOF PENETRATIONS INACCORDANCE WITH NFPA.12. CONTRACTOR TO PROVIDE LOW POINT DRAINS AND HIGH POINT VENTS PER NFPA ANDAGA CODES.GENERAL NOTES:SPECIFICATIONS:BTS ENGINEER:1. DELIVERY AND SET UP OF GENERATOR.GENERAL CONTRACTOR:1. RUNS STUB-UPS FOR LP GAS TO GENERATOR.2. COORDINATE DELIVERY OF LP GAS LINE TO THE SITE.3. PULLS ALARM WIRES, START CIRCUIT WIRES, CONTROL CIRCUIT WIRES, AND LINE VOLTAGE WIRES FROM THE PPC TO THEATS AND TO THE GENERATOR. HOME RUNS WIRES BACK TO THE ATS.4. GROUNDS FOR GENERATOR.GENERATOR MANUFACTURER CERTIFIED ELECTRICIAN:1. COMPLETES FUEL CONNECTIONS.2. TERMINATES ALARMS AND CONTROL CIRCUITS TO THE GENERATOR.3. INSTALL FUEL REGULATORS.4. FINAL INSPECTION AND START UP.5. NOTIFY OPERATIONS (CELL TECHS) TWO DAYS PRIOR TO START-UP SCHEDULE, PLAN ON CELL TECH ARRIVAL EARLYAFTERNOON. IF START-UP PROBLEMS OCCUR, NOTIFY CELL TECH OF DELAY BEFORE NOON.6. RUN LOAD TEST (ADDITIONAL COST TO VERIZON) AS REQUIRED, MOSTLY IN CORE.7. EMAIL COPY OF START-UP CHECK OFF LIST TO VERIZON.CELL TECH:1. CELL TECH TO PUNCH DOWN ALL ALARMS IN CROSS CONNECT AND BTS.2. CELL TECH TO VERIFY START-UP AND SIGN OFF ACCEPTING GENERATOR.3. CELL TECH TO NOTIFY VIA TEXT MESSAGING OF ACCEPTANCE.GENERATOR INSTALLATION RESPONSIBILITIES:NOTE: BEFORE RUNNING GENERATOR OR INTERRUPTING POWER, NOTIFY THE NETWORK OPERATIONS CENTER (NOC) AND APPROPRIATE CELL TECH.1. INSPECT ALL CONNECTING CIRCUITS (GROUND LEADS - START LEADS - BLOCK HEATER - BATTERY CHARGER - POWER OUTLET LEADS) AND ANCHORING OFTHE GENERATOR.2. VERIFY ALL CIRCUITS ARE TERMINATED CORRECTLY AND CORRECT WIRE SIZES ARE USED, THE BATTERY IS CONNECTED, THE CHARGER ACTIVATED AND THEBATTERY IS CHARGING.3. CHECK ALL LIQUID LEVELS.4. PLACE ATS IN THE MANUAL MODE AND PROGRAMMED TO SET THE EXERCISER CLOCK TO OPERATE EVERY TWO WEEKS FOR ONE HOUR UNDER LOAD.5. FUEL SYSTEM IS INSPECTED AND CHECKED FOR LEAKS. VERIFY CORRECT PRESSURE (4 TO 6 OUNCES) AND VERIFY PIPE SIZE.6. DOCUMENT THE MODEL AND SERIAL NUMBER (SEND INFORMATION TO OPS AND BTS ENGINEER).7. PREPARE FOR A NO LOAD (MANUAL) START-UP - IF REQUIRED.8. VERIFY ATS IS IN MANUAL CONTROL POSITION.9. START UP GENERATOR MANUALLY AND VERIFY VOLTAGE AND FREQUANCY. SET VOLTAGE FOR 230 VOLTS AND FREQUANCY FOR 60 HERTZ.10. VERIFY ENGINE RUN ALARM IS ACTIVATED AND THERE IS CONTINUITY TO TELCO BOX.11. INDUCE LOW OIL PRESSURE, HIGH WATER TEMP, OVER/UNDER VOLTAGE/FREQUANCY FAULTS SEPARATELY AND VERIFY THE ALARM IS ACTIVATED ANDHAS CONTINUITY TO TELCO BOX.12. PLACE ATS CONTROLS IN AUTOMATIC.13. MANUALLY DISCONNECT COMMERCIAL POWER AND VERIFY GENERATOR TRANSFER.14. ALLOW GENERATOR TO RUN UNDER LOAD FOR ONE HOUR - IF REQUIRED AND RECORD LOAD, COOLANT TEMPERATURE AND VOLTAGE (SENDINFORMATION TO OPS).15. RESTORE COMMERCIAL POWER AND CHECK FOR TRANSFER, GENERATOR WILL REMAIN RUNNING FOR APPROXIMATELY 5 MINUTES FOR COOL DOWN.16. COMPLETE ALL REQUIRED START-UP DOCUMENTATION LOCATED IN THE MANUAL, SCAN INTO JOB FILE AND EMAIL COPY TO KATOLIGHT AND OPS.17. CONTACT OPS TWO DAYS PRIOR TO TESTING.GENERATOR MANUFACTURER / VERIZON WIRELESS START-UP PROCEDURES:1. PIPE (LOW-PRESSURE): STEEL PIPE; ASTM A53, TYPE OR S, ELECTRIC-RESISTANCE WELDED OR SEAMLESS, GRADE A OR B, SCHEDULE 40GALVANIZED STEEL, PAINTED YELLOW.2. PIPE FITTINGS (ABOVE GROUND):A. GRAY-IRON THREAD FITTINGS: ASME B16.4, CLASS 125, GALVANIZED STANDARD PATTERN.B. UNIONS: ASME B16.39, CLASS 150, BLACK MALLEABLE IRON, FEMALE PATTERN, BRASS TO IRON SEAT, GROUND JOINT.C. TRANSITION FITTINGS: TYPE, MATERIAL, AND END CONNECTIONS TO MATCH PIPING BEING JOINED.D. PROVIDE DI-ELECTRIC UNIONS WHERE REQUIRED BETWEEN DIFFERENT METALLIC PIPE MATERIALS.3. PIPE (UNDERGROUND): POLYETHYLENE PIPE; ASTM D 2513, SDR 11 OR IN ACCORDANCE WITH LOCAL CODES AND REGULATIONS.4. POLYETHYLENE FITTINGS (UNDERGROUND): ASTM D 2683, SOCKET TYPE OR ASTM D 3261, BUTT TYPE WITH DIMENSIONS MATCHINGASTM D 2513, SDR 11, POLYETHYLENE PIPE.5. TRANSITION FITTINGS: MANUFACTURED PIPE FITTING FOR CONNECTION TO POLYETHYLENE PIPE AND WITH ONE ASTM A 533 / A 53M,SCHEDULE 40, GALVANIZED STEEL PIPE END FOR THREADED CONNECTION TO GALVANIZED STEEL PIPE.6. SERVICE-LINE RISER: MANUFACTURED PIPE FITTING WITH POLYETHYLENE PIPE INLET FOR CONNECTION TO UNDERGROUNDPOLYETHYLENE PIPE RISER SECTION WITH PROTECTIVE-COATED, ANODES, STEEL CASING AND THREADED OUTLET FOR THREADEDCONNECTION TO ABOVE GROUND STEEL PIPING.NOT TO SCALELP GAS SYSTEM FOR BACKUP GENERATORGROUND LEVEL3/4" MDPE GAS SUPPLY LINE. PROVIDE PROTECTIVECOATING FOR UNDERGROUND PIPE. INSTALLER TO VERIFYGENERATOR REQUIRED FLOW RATE PRIOR TOINSTALLATION. SUPPLY LINE SHALL BE BURIED 3' MIN. BELOWGRADE AND MARKED WITH BURIED FLAGGING AT 3' O.C.12" BELOW GRADEAGA APPROVED FLEXIBLECONNECTION PIPE (TYP.)PROPOSED 3/4" SCH. 40STL. GAS PIPE W/THREADED FITTINGSAPPLIANCESHUT-OFF VALVEPRESSURE REGULATOR TO BE SUPPLIED AND INSTALLEDBY GENERAL CONTRACTOR (SERVICE TO 11" W.C.)UNIONPROPOSED 3/4" SCH. 40 STL. GAS PIPE(FROM REGULATOR TO GENERATOR)FLEXIBLE PIPECONNECTIONNOTE:GENERATOR SHOWNSCHEMATICALLY. SEE SITE PLANSHEETS FOR GENERATOR LAYOUT.NOTE:REFER TO GENERATORMANUFACTURER'SRECOMMENDATION FOR GAS PIPINGCONNECTION SIZE ANDREQUIREMENTS.POLYETHYLENE TO METAL PIPETRANSITION FITTINGS (TYP.)PROPOSED VERIZON50 KW LP GASGENERATOR(220 C.F.H.)*NOTE: PIPE SIZE IS BASED ON A MAX. 125' PIPE LENGTHPROPOSEDLP GAS TANK (~10 PSI )USE 1-1/4" STRAP OR 5/16" CABLESIF SINGLE STRAP IS USED,PLACE AS CLOSE TO CENTEROF TANK AS POSSIBLEAUGER STYLE EARTH ANCHORNOTE:1. LOADING FOR STRAP AND CABLECONDITIONS BASED UPON 3,150 LBWORKING LOAD CAPACITY2. ALWAYS CHECK FOR UNDERGROUNDUTILITIES PRIOR TO INSTALLATIONPROPOSED DOUBLE CHECKFILL VALVE W/ CAP(P/N: ME600)PRESSURE REGULATOR TOBE SUPPLIED AND INSTALLEDBY GENERAL CONTRACTOR(2 P.S.I.)11/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-1.1REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-1.2REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-2REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-3REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #31572PANEL SCHEDULECOMMON VzW DC PLANT RECTIFIER REQUIREMENTSRECTIFIERINPUT FLA CURRENT AT 240 VAC(EACH RECTIFIER)2 RECT / BRANCH CIRCUIT(PREFERRED APPROACH)1 RECT / BRANCH CIRCUIT(ALT APPROACH)GE 75A(NE075AC48xxxx or sim)22 AMPS (MAX)60A/2P #3 THHN30A/2P #10 THHNNOTES:1. ALL EQUIPMENT SHALL BE NEMA 3R RATED.2. ALL EQUIPMENT SHALL BE LIGHTNING PROTECTED IN ACCORDANCE WITH TIA-222-G AND VERIZONWIRELESS STANDARDS.3. CONDUCTOR SIZES AND DISTANCES HAVE BEEN SIZED FOR 3% MAX VOLTAGE DROP (TOTAL SYSTEMVOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST DEMAND SHALL NOTEXCEED 5%).4. WIRE SIZING AND MAXIMUM DISTANCE FROM GENERATOR TO ILC ASSUMES POWER FACTOR OF 0.9.5. BELOW GRADE CONDUIT SHALL BE SCHEDULE 80 PVC. ABOVE GRADE CONDUIT SHALL BE GALVANIZEDRIGID CONDUIT. BELOW GRADE PVC CONDUIT SHALL TRANSITION TO GRC PRIOR TO RISING ABOVEGRADE. ALL BENDS SHALL HAVE A MINIMUM 24" RADIUS. ALL FITTINGS SHALL BE SUITABLE FOR USE WITHTHREADED RIGID CONDUIT. VERIFY CONDUIT TYPE WITH LOCAL CONSTRUCTION MANAGER AND ADJUSTIF NECESSARY. ALL CONDUIT SHALL MEET NEC, STATE, AND LOCAL CODE REQUIREMENTS AS REQUIRED.TO UTILITY TRANSFORMER200A200A ILC50KWGENVERIZON WIRELESS50KW LP GAS GENERATOR3-#3/0 AWG6 AWG EG1-1/2" CONDUIT(185 LF MAX)1" CONDUIT FOR GEN CONTROLS & ALARMS200A4-#12 AWG,1-#12 AWG EG,1" CONDUIT (FOR GEN HEATER & BATT. CHARGER)NOTE: THE GENERATOR USED INCONJUNCTION WITH A 2-POLE ILCWITH A SOLID NEUTRAL IS NOT ASEPARATELY DERIVED SYSTEM. ASSUCH, DO NOT BOND THENEUTRAL TO GROUND AT THEGENERATORINTEGRATEDLOADCENTERVERIZONWIRELESS ILCCABINETWITH2P/200AUTILITYBREAKER3-#3/0 AWG#6 AWG EG2" CONDUIT(130 LF MAX)200AMUTILITY METER 120/240 VACPRIMARYCABINET8-#10 AWG, 1-#10 AWG EG, IN (1) 1-1/2"CONDUIT(INSTALL (1) 1-1/2" CONDUIT WITH PULL STRINGFOR FUTURE RECTIFIER CIRCUITS) ROUTE CONDUITABOVE GROUND SECURED TO EQUIPMENTFRAME200A4 AWG MBJ4 AWG GECSERVICEDISCONNECT/CIRCUIT BREAKERGEN MAIN DISCONNECT/FUSED SWITCHGFCIRECPT.LIGHT3-#12 AWG#12 AWG EG1" CONDUITOVP-1212-#6 AWG (6 PAIRS)#6 AWG EG2" LMFC1" CONDUIT FOR GEN & ILC ALARMSNOTES:* ADD (1) ADDITIONAL 2" CONDUIT FORDARK FIBER (2 TOTAL) IF REQUIRED BYLOCAL MARKET FACILITIES, VERIFY PRIOR TOCONSTRUCTION. (ADD 2 PULL STRINGS TOEACH CONDUIT)** VERIFY EBH REQUIREMENTS WITH TELCOPROVIDER PRIOR TO CONSTRUCTION. (ADD2 PULL STRINGS TO EACH CONDUIT)FIBER HANDHOLE/MEET-ME POINT ATROW FOR EBHPROVIDER (IF NEEDED)EBH FIBER HANDHOLE (ORJUNCTION BOX ONCOMMON USE UTILITYFRAME) AT COMPOUND(IF NEEDED)VZW EQUIPMENT FRAMETERMINATION POINT(18"X18" FIBER JUNCTION BOXFOR DARK FIBER OR CHARLESCABINET AS NEEDED FOREBH)EBH DEMARC(IF REQUIRED, VERIFYREQUIREMENTS WITH EBHPROVIDER)(1) 2" CONDUIT FOR EBH **(1) 2" CONDUIT(FOR EBH IF NEEDED)(1) 2" RGC STRAIGHT RUN AT GRADE (CLAMP TOEQUIPMENT FRAME POSTS), TRANSITION TO 2"LMFC AT EACH FOR EQUIPMENT CABINETCONNECTIONSPRIMARY CABINETOVP-121-1/2" LMFC FOR FIBERAND ALARM (SHIELDEDCAT 5) AS NEEDEDATT CIENA1-1/4" TELCO SEAL TIGHTCONDUIT (TYP.)1-1/4" FIBER FEED SEAL TIGHTCONDUIT (TYP.)NOTE:PANEL SCHEDULE AND SINGLE LINE DIAGRAMREPRESENT A SITE WITH A NEW GE POWERPLANT, 50 KW LP GAS GENERATOR, AND TWOSOURCE ILC (THREE SOURCE ILC OPTIONAL ASNEEDED). ADJUST AS NECESSARY PER LOCALSITE CONDITIONS.FIBER HANDHOLE/MEET-ME POINTAT ROW FOR VZWDARK FIBERVZW FIBERHANDHOLE FORDARK FIBER ATCOMPOUND(1) 2" CONDUITFOR DARK FIBER *(1) 2" CONDUIT(FOR EBH IF NEEDED)ELECTRICAL SINGLE LINE DIAGRAMPANEL SCHEDULEFIBER SINGLE LINE DIAGRAM:SUB TOTAL AMPS135111111179111315111719212311.251.251.25111111112468111416182022241210SUB TOTAL AMPS:FACTORED TOTALPROPOSED VERIZON WIRELESS PANEL SCHEDULEPANEL NAMERATED VOLTAGEMAIN BREAKERMOUNTENCLOSURE TYPEPOSUSAGEFACTORBUS AMPSLOADPOLESAMPSMODEL NUMBERL1L2PHASE / WIREBUS RATINGNEUTRAL BARAICBUS AMPSLOADAMPSPOLESUSAGEFACTORPOSNOTESVZW ILC120 240VOLTSAMPS200SURFACENEMA 3RL1L2INTERSECT AA300G-1PH-3R13200YESKEY DOORLATCHHINGED DOORYESYESL1L218181818181818181212522221818181818181818222230A.30A.30A.30A.30A.30A.30A.30A.20A.20A.20A.111RECTIFIERRECTIFIERRECTIFIERRECTIFIERRECTIFIERRECTIFIERRECTIFIERRECTIFIERGFI RECPT./LIGHTBLOCK HEATERBATT. CHARGER65K8793.2572 72165.25 159VOLTSAMPS(WATTS)VOLTSAMPS(WATTS)VOLTAGE AMPSTOTAL VOLTAGE AMPSMAX AMPSMAX 125%2880288028802880192019201920288028802880288017,28011,52028,8001201501. ALL CONDUCTORS ARE TYPE THWN (75°C) COPPER.2. MAXIMUM LENGTH OF RUN FOR RECTIFIER CIRCUITS IS 50FT.3. INTERSECT/GENERAC INTEGRATED LOAD CENTER INCLUDES 200A. MAIN DISCONNECT AND TRANSFER SWITCH FOR PORTABLE OR PERMANENT GENERATOR4. RECTIFIER LOADS ARE CONSIDERED TO BE NON-CONTINUOUS.5. IF ADDITIONAL FUTURE LOADS ARE ADDED WHICH CAUSE TOTAL DEMAND TO EXCEED GENERATOR BREAKER SIZE, BACKUP POWER SYSTEM SHALL BE EVALUATED ANDUPGRADED AS NECESSARY.VERIZON WIRELESS EMERGENCYGENERATOR E-STOP#16AWG1/2" CONDUIT11/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-4REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-5REVISION:SHEET NUMBER:DRWNREVDESCRIPTIONDES./QADATE8000 AVALON BLVD, SUITE 700ALPHARETTA, GA 30009VERIZON WIRELESSSITE NUMBER: 578574BU #: 812565MAYPORT1545 MAIN STREETATLANTIC BEACH, FL 32233EXISTING 192'-6" SELFSUPPORT TOWERTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJAVAD K. PARSA, P.E. ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ISSUED FOR:verizon7701 E. TELECOM PARKWAYTEMPLE TERRACE, FL 336370 11/29/22 FSISSUED FOR FINALSMAT1355 WINDWARD CONCOURSE, SUITE 410ALPHARETTA, GA 30005TEL: 678-990-2338FL COA #3157211/29/2022