Loading...
325 Country Club Ln POOL20-0032 COAB Permit Form with Conditions - RenewedOWNER:ADDRESS:CITY:STATE:ZIP: GROVER WILLIAM HOWE JR 325 COUNTRY CLUB LN ATLANTIC BEACH FL 32233-5502 COMPANY:ADDRESS:CITY:STATE:ZIP: ISLAND POOLS,LLC 1546 LINKSIDE DR ATLANTIC BEACH FL 32233 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171962 0000 SELVA MARINA UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 325 COUNTRY CLUB LN SWIMMING POOL SWIMMING POOL RESIDENTIAL SWIMMING POOL - Renewed $73365.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 11/10/2020 PERMIT NUMBER POOL20-0032 ISSUED: 11/10/2020 EXPIRES: 7/20/2024 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BLDG 3RD PLAN REVIEW FEE 455-0000-322-1006 0 $75.00 BUILDING PERMIT 455-0000-322-1000 0 $376.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $188.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $10.34 STATE DCA SURCHARGE 455-0000-208-0600 0 $6.89 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $906.23 3 PUBLIC WORKS POST CONSTRUCTION TOPO SURVEY INFORMATIONAL Notes: If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. 4 PUBLIC WORKS POOL WELLPOINT INFORMATIONAL Notes: Pool Wellpoint (if used) must discharge into vegetated area 10 foot minimum from street or drainage feature (swale, structure or lagoon). 5 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. 6 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 7 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 8 PUBLIC WORKS TOPO SURVEY INFORMATIONAL Notes: Must provide a topographic (TOPO) survey with water retention for final Inspection. 9 PUBLIC WORKS DECKING REMOVED INFORMATIONAL Notes: All old decking and debris must be removed from job site by Contractor. 10 PUBLIC WORKS OTHER PUBLIC WORKS CONDITION INFORMATIONAL Notes: Water retention must be 5 feet off property line and 10 feet from existing structures. 2 of 2Issued Date: 11/10/2020 PERMIT NUMBER POOL20-0032 ISSUED: 11/10/2020 EXPIRES: 7/20/2024 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 POOL20-0032 Building Permit Application E City of Atlantic Beach Building Department O ~ 800 Seminole Road, Atlantic Beach, FL 32233 711, rf Phone: (904) 247-5826 Email: Building-Dept@coab.us Updated 10/9/18 **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Job Address: 82-,5 Cairnf\J CI Uk:J kn , A----H~vrh c.£r:a:6 1 F:6~m? Number: ________ _ Legal Description 2.7 lP-wA ik·-2'5-~E z/va. t'.b2t)i10 Ul:'1112 H}f-~ RE# 111'.:flo2-CQ::b Valuation of Work (Replacement Cost) S731 '.2102, 00 Heated/Cooled SF g / I~ 5 Non-Heated/Cooled ____ _ • Class of Work: ~w □Addition □Alteration □Repair □Move □Demo □Poo l □Window/Door • Use of existing/proposed structure(s): □Commercial ~sidential • If an existing structure, is a fire sprinkler system installed?: □Yes ~ ·ect? □Yes m Removal Permi am'o Describe In detail the type of work to be performed: vow---d ?LUi wm;1~ pro I ' IV1 Florida Product Approval# ___________________ for multiple products use product approval form Pro · Own rney or Agency Letter Requ ired) ___________________ _ Contractor Inf · --'iC~Z-...L?--J=:!--!..a::...4-':::ti:=:~-----Qualifying Agent_ 12oJa/J ~'t ·-::=::~ .~q_1_!~~~~~~ir::::::==----;-::-;~::--; City ~vqJC /x.h State H-Zip ?22 3? "" Job Site Cont~ct ~--------------- State Certification/Registration# -=-=L+--""---L....l.=-+..--E-Ma il r<.\e IS \~'2· Qq Architect Name & Phone# ~ c Engineer's Name & Phone# / Workers Compensation Insurer _______________ OR Exempt,d' Expiration Date _______ _ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTR ICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public reco rds of th is county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECO~~CE OF COMMENCEMEN_. --!::/=====---------~ (Signature of Owner or Agent) ~nally Known OR [ ] Produced Identification Type of Identification: _____________ _ Signed and sworn to (or affirmed) before me this--ZO day of ~ ,Ze>'Zb . P . -+-=--:--b=c---+-.--,,,----.--- /;fi.~~;¥~';;-._ KAY KEEL SMITH f•1:A·=·l Commiss ion# GG 129904 ~sonally Known OR ,".'. ·•· E · <.:~~-.... 0:l'/ xp,re s November 30 2021 [ ] Produced ldentificatio '••,.~f.f,\,••·· Bondad Tllru Troy Fain Jns:ranca 800-JS5-7ofg Type of Identification: -~~~~~~~~;.;.;;;;=:::::::J POOL20-0032 TREE & VEGETATION AFFIDAVIT City of Atlantic Beach Community Development Department 800 Seminole Road Atlantic Beach, FL 32233 (P) 904-247-5800 SITE INFORMATION ADDRESS 325 Country Club 4,i.Atlantic Beach, FL 32233 SUBDIVISION Selva Marina Unit 2 RE# 171962-000 APPLICANT INFORMATION NAME Howie Grover FOR INTERNAL OFFICE USE ONLY PERMIT# ______ _ BLOCK 5 LOT 3 0 RESIDENTIAL 0 COMMERCIAL 0 OTHER ----------------------------PHONE# (904)334-5421 ADDRESS 325 Country Club 1-YJ . CELL# CITY Atlantic Beach STATE FL ZIP CODE 32233 ------------- EMAIL rd@islandpools.org 18) OWNER 0 LEGAL AUTHORIZED AGENT I affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation", of the Municipal Code of Ordinances for the City of Atlantic Beach Florida and/or I have participated in a pre- application meeting with the Administrator of those regulations. Subsequently, I affirm that no regulated trees and no regulated vegetation will be damaged, destroyed and/or removed from the above-described property and/or adjacent properties including right-of-way. I HEREBY CERTl~VIDED IS CORRECT, s;gnaMe of Pmperty Owne,(s) o, Autho,i,ed Agent ~ ....--:'. bbu G, I ~ ,q r-2.o ,z,:, Slt-JRE OF AP !CANT PRINT OR TYPE NAME DATE SIGNATURE OF APPLICANT (2) PRINT OR TYPE NAME Signed and sworn before me on this ?-~ day of ~ ?-me) by Identification verified: _____________________ _ Oath Sworn:~ D No DATE Stateof pc_ nu1.r.,._,.1 County of-'--Y-d ____ _ •••• ,:;.~~~,:.;,.,, KAY KEEL SM ITH My Commission expires /J?·· -~, · · ;i r.: \;.:. .:;J Exp ires November 30, 2021 04 TREE AND VEGETATION AFFIDAVIT03.01.20 18 ·-;~~~·r.t~?,t>" Bonded Thru Troy Fain Insurance 800-385-7019 POOL20-0032 Revision Request/Correction to Comments City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Bu i l d ing-Dept@co ab.u s · 0 Rev is ion to Issued Permit OR D Co r rections to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. PERMIT#: _______ _ Date: / U -I ~ -<-0 Project Address: _3.....,.,,.ct-...._..S,__..,.(.....,D=.....U'"tv'-"''-iJ--'t',_~,,_/_C=-.,\.__,u::..cb=--------------------' Contractor/Contact Name: _:::g._,_·---"t),<.._...::G~r~o.....,f,---------------------=--------- Contact Phone : 3 "3 L\ S-~ \ Email : cd @ i"s lu,uJ pudl s--o r-3 Description of Proposed Revis ion / Corrections: I_J:_,___D.;:;;._ ..... G~r-.... a1---1'f'---------affir m the revision/correction to comments is inclusive of the proposed changes. (pri nted name) ~posed revision/corrections add additional square footage to original subm ittal? V 0 Yes (additional s.f. to be added: ____________ ) ~ropose~ revis ion~c_orre~ions ad~ addi_ti~nal i ncrease in building value to original submitta l? ~ 0 Yes {add1t1onal increa se in building value: Contractor must sign if increase in va luation ) *S ignature of Contractor/ Agent:~~====---~'.__ ______________ _ (Offi ce Use Only) ~pproved D Denied D Not Applicable to Department Permit Fee Due$ _____ _ Re vi si o n/Plan Re v iew Comments ____________________________ _ Department Review Required: Building Planning & Zoning Tree Administrator Pub l ic W o rks Public Utilities Public Safety Fire Servic es Reviewed By Date Updated 10/17/18 oolguard® IMPORTANT OPERATING INSTRUCTIONS MANUAL HELPFUL HINTS & TIPS "MEETS REQUIREMENTS OF ASTM SAFETY SPECIFICATION F 2208" CE@ MODEL PGRM - 2 85dB Horn at 10 Feet This product has been designed to aid in the detection of unwanted intrusions into unsupervised pools. POOLGUARD IS A SAFETY ALARM SYSTEM AND NOT A LIFE SAVING DEVICE. "This device is not intended to replace any other safety consideration -i.e., adult supervision, lifeguards, fences, gates, pool covers, locks, etc., and some devices may not detect gradual entry:' GENERAL POOLGUARD is the result of quality design and manufacturing techniques that are a standard at PBM Industries, Inc.; a company dedicated to high quality products. POOLGUARD is a result of that dedication and we guarantee and stand behind the POOLGUARD alarm system. POOLGUARD Pool Alarms have been tested and comply to the ASTM Safety and Performance Standard for Pool Alarms, ASTM F 2208, see insert. POOLGUARD is an electronic monitoring system that automatically sounds an alarm when children or pets fall into your unsupervised pool. POOLGUARD is a portable, self-contained, lightweight unit that is safe and simple to operate. Entry into the pool will be detected by the unit's electronic sensor, triggering a loud pulsating alarm and an internal RF transmitter. The remote receiver will receive the transmitted signal and sound an alarm within the home. INSPECTION POOLGUARD is packaged in a shipping carton that minimizes the chance of damage due to handling. Check for damage and confirm that the con- tents of the carton include the following items: • POOLGUARD Unit • Handle • Remote Receiver and Power Supply • Operating Instructions Manual • Warranty and Registration Card If an item is missing, contact either the place of purchase or PBM Industries, Inc. for replacement. CARE AND HANDLING POOLGUARD is constructed from sturdy plastic to withstand the adverse moisture environment of a swimming pool. Care needs to be taken when handling to ensure against being dropped, kicked, etc. Also, be sure to remove the pool unit and set it away from activity in the upright position when the pool is being used, (See Figure 1 }. If the pool unit accidentally falls into your pool, remove it immediately and drain the water from it. Take the unit apart as indicated in the Battery Replacement Procedure and remove the battery. Tip and shake unit and remove all excess water from inside the unit and the battery, and the circuit board area with a paper towel or cloth. Completely test unit before each use as described in manual to ensure proper operation. (Remember to always remove the pool unit from the pool while swimming and set it aside away from pool activity}. •----------- ATTACHING HANDLE The two handle screws are located in the top of the alarm, remove them and attach the handle, (See Figure 1 ). INSTALLING YOUR ALARM RESET/SLEEP SWITCH (SEE FIGURE 1) RESET: When the pool unit is installed in the pool and the horn is sounding; press the reset/sleep switch once to silence the alarm. SLEEP MODE: When the pool unit is removed from the pool and the horn is sounding; press and hold the reset/sleep switch for 3 seconds to silence the alarm. The pool unit will automatically wake up when it is installed into the pool. THE POOL UNIT WILL NOT GO INTO SLEEP MODE ONCE IT IS INSTALLED IN THE POOL! SILENT INSTALLATION AND REMOVAL FEATURE • The poolguard system will sound an alarm (Horn will sound) when you install or remove the pool unit from your pool. If you would like the poolguard system not to sound an alarm (horn will not sound) when you install or remove the pool unit from your pool, follow the directions below. 1.SILENT INSTALLATION (HORN WILL NOT SOUND) • Press and hold the reset/sleep switch for 3 seconds, until you hear the pool units horn chirp. Release the reset/sleep switch, you now have 15 seconds to gently and slowly install the pool unit into your pool without the horn sounding. POOLGUARD WILL INSTANTLY BE MONITORING YOUR POOL FOR AN INTRUSION. 2. SILENT REMOVAL (HORN WILL NOT SOUND) • Before removing the pool unit from your pool. Press and hold the reset/sleep switch for 3 seconds, until you hear the pool units horn chirp. Release the reset/sleep switch, you now have 5 seconds to remove the pool unit from your pool without the horn sounding. IMPORTANT: THIS DOES NOT TURN POOLGUARD OFF, IF THE POOL UNIT IS NOT REMOVED IT WILL CONTINUE TO MONITOR YOUR POOL FOR AN INTRUSION. (Cont. on next page) e SILENT INSTALLATION AND REMOVAL FEATURE (Cont.) 3. POOLGUARD HAS DESIGNED THIS FEATURE FOR "ONLY"THOSE WHO HAVE THE RESPONSIBILITY OF INSTALLING OR REMOVING THE ALARM FROM YOUR POOL! BATTERY INSTALLATION / REPLACEMENT (Battery not included) POOLGUARD is powered by a standard 9 -volt alkaline battery. To install or replace the battery: • Remove the screw from the bottom of the unit, {See Figure 1 ). • Carefully slide out electronics assembly; do not pull or jerk on internal hook up cable. (If necessary, gently shake unit to remove assembly.) • Remove old battery and check for leakage or corrosion. (Remove any leakage or corrosion if present before installing new battery.) • IMPORTANT: WHEN A 9V BATTERY IS FIRST INSTALLED IN THE POOL UNIT, THE HORN WILL SOUND. TO SILENCE THE ALARM PRESS AND HOLD THE RESET/SLEEP SWITCH FOR 3 SECONDS. THIS PLACES THE POOL UNIT IN SLEEP MODE. THE POOL UNIT WILL AUTOMATICALLY WAKE UP WHEN IT IS INSTALLED INTO THE POOL. • Install new battery by attaching snap connection and sliding into battery holder. • Slide electronics assembly into pool unit; do not pinch internal hookup cable. • Replace the screw, hand tighten until screw is all the way in and flush against the pool unit. To prevent possible damage, battery should be removed whenever storing the alarm, for an extended period of time. LOW BATTERY FUNCTION The POOL UNIT AND THE REMOTE RECEIVER will beep once approximately every 20 seconds to alert you that the battery is low in the pool unit and needs to be replaced. 0----------- HORN 85dB at 10 feet ELECTRONICS ASSEMBLY l RESET/SLEEP SWI TCH HANDLE SCREWS "~--- - PLACEMENT IN YOUR POOL POOL UNIT FIGURE 1 UPRIGHT POSITION Figure 2 illustrates locations best suited for detecting intrusions from any area of the pool. If your pool is larger than 800 square feet, if you have more than 2 return lines, any concerns about the size, or if you have an irregular shaped pool or water features such as waterfalls, please call customer service to clarify the recommended number of alarms and locations for alarms: 1-800-242-7163. Poolguard Pool Alarms have been tested and comply to the ASTM Standard Specifications for Pool Alarms ASTM F 2208, in a 16' x 32' pool. POOLGUARD alarms can be used in pools up to 20' x 40' or 800 square feet. --LJ FIGURE 2 Pools 800 Square Feet and Smaller. (Cont. on next page) -----------• PLACEMENT IN YOUR POOL (Continued) POOLGUARD automatically compensates for variations in pool levels within the unit's operating range. The unit utilizes a sensing throat which projects into the water and is designed to operate in most pools with an in-wall skimmer. The sensing throat cannot be less than 2 inches, (See Figure 3), and not more than 7 inches into the water, POOLGUARD recommends that the sensing throat be approximately 4" in the water POOLGUARD can be used with SOLAR BLANKETS on the pool. POOLGUARD can also be used in spas. SENSING THROAT CANNOT BE LESS THAN 2" IN THE WATER, POOLGUARD RECOMMENDSTHAT THE SENSING THROAT BE APPROXIMATELY 4" IN THEWATER IMPORTANT ► SUPPORT BLOCK FIGURE 3 POOLGUARD may not function properly if your pool's water level is not maintained within the required levels of your alarm. Also, the unit may not operate effectively while certain types of automatic pool cleaners are in operation. Some irregular shaped decks may not provide a level foundation for the unit by the pool's edge. This minor problem can be overcome by appropriately supporting the unit, (See Figure 3). STABILIZING YOUR POOL ALARM The Alarm Stabilizing Pin (ASP) is factory installed onto your pool alarm. Tools needed to install your alarm are: One 5/16" masonry drill bit that can be found at your local hardware store, a drill, a pencil, a tape measure or yard stick. 1. Position your pool alarm so that the sensing throat is in the water and the ASP is touching the deck, (leave a small space no more than 3/8" between the sensing throat and the top edge of your deck or coping), (See Figure 4). 2. Mark with a pencil the spot where you wish to drill the hole for the ASP. 3. With the 5/16" masonry drill bit, drill a hole 2 1/4" inches deep, as straight as possible. (Cont. on next page) 0----------------- STABILIZING YOUR POOL ALARM (Continued) 4. Clean off the debris and install the alarm by placing the ASP into the 5/16" diameter by 2 1 /4" deep hole. 5. Your Pool Alarm is now ready for use. If you have any questions or need help with installation, please give us a call at 1-800-242-7163. 6. Be sure to keep your ASP hole clean from debris and dirt so that your alarm will always lay flat on the pool deck when installed. REMEMBER THAT THE POOL UNIT MUST BE REMOVED FROM POOL BEFORE SWIMMING! ALARMS STABILIZING Pl SMALL SPACE, NOMOR~---- THAN 3/8" SENSING TH ROA-------• l WATER LEVEL MARK LOCATION FOR 5/16" DIAMETER & 21/4" DEEP HOLE IN DECK POOL DECK FIGURE 4 Sensing throat cannot be less than 2" in the water, POOLGUARD recommends that the sensing throat be approximately 4" in the water. TEST BEFORE USING To ensure effectiveness, test POOLGUARD every time you place it into the pool by performing the following procedure: •POOLGUARD DOES NOT HAVE AN ON/OFF SWITCH When the alarm is in the pool it is always in the ON position and cannot be turned off. When the alarm is out of the pool it is always in the OFF position. •To test your alarm push an object of appropriate volume and weight off the deck edge at the farthest location from the alarm. (A four (4) gallon jug of water or 3-one (1) gallon jugs of water tied together are ideal for testing.) The alarm should sound when the water action caused by the intrusion reaches the unit. It may take a few seconds for the alarm to react to the water action. (Cont. on next page) -----------• TEST BEFORE USING (continued) •After resetting the alarm and allowing time for the water action to settle, repeat the procedure from another point in the pool until you are confident of detection performance. •POOLGUARD includes a timer function which automatically resets the unit after the alarm has sounded for approximately 5 minutes. ADJUSTING YOUR RETURN LINE FITTINGS The POOLGUARD alarm should not be placed too close to a return line, also do not place POOLGUARD in a location in the pool where a return line is pointing in the alarms direction. Water turbulence may be too strong, falsely setting the alarm off or the water turbulence may interfere with the alarms ability to detect an intrusion. If you have more than 2 return lines please call customer service at 1-800-242-7163. It is very important in pools to adjust all the eyeball fittings on your return lines so that the water flow will not interfere with your pool alarm. Point all the eyeball fittings down and your pool will still circulate properly and this will allow POOLGUARD to function properly, (See Fgure 5). Pointing the eyeball fittings down also helps prevent algae growth. FIGURE 5 CORRECT INCORRECT 8,--------------- POOLGUARD REMOTE RECEIVER The POOLGUARD REMOTE RECEIVER has been integrated with the standard POOLGUARD unit to provide a wireless remote alert operating at distances of up to 200 feet. The POOLGUARD REMOTE RECEIVER sounds an alarm in the house when the POOLGUARD unit is activated at the pool.The remote system consists of the following functional elements: • A coded pulse receiver (Remote Receiver), (See Figure 6). • A standard wall outlet power supply, (See Figure 6). The REMOTE RECEIVER is a compact unit powered by a UL and CSA approved AC/DC power supply. The REMOTE RECEIVER can be placed on a table or a counter top inside the house. The pulse coded radio frequency signal is transmitted from the pool unit and is received and decoded to sound the remote receiver. The remote receiver will sound for an additional 3 seconds after the pool unit has been silenced. If the REMOTE RECEIVER beeps once approximately every 20 seconds, it is indicating that the 9v battery in the pool unit is low and needs to be replaced. After you have purchased your POOLGUARD alarm and you wish to add another remote receiver to your alarm system you can acquire one from PBM Industries, Inc. Contact PBM by phone or mail or contact your place of purchase. POWER SUPPLY • 85dB Horn at 1 0 feet ~ REMOTE RECEIVER FIGURE 6 ----------~o TO OPERATE YOUR REMOTE RECEIVER Try to locate your REMOTE RECEIVER in a convenient part of your house close to the pool. Avoid steel walls or any other large metal objects or obstructions that might interfere with the signal reception. The REMOTE RECEIVER has to be placed on the same level or a level above the pool in the house (do not place receiver in an underground basement). The ideal location for your REMOTE RECEIVER would be by a window overlooking your pool. Test your REMOTE RECEIVER in different locations in your house to find the best working place for your receiver. Connect the power supply to any 120V, electrical outlet and insert the jack into the receiver. Check that indicator light is on. Your REMOTE RECEIVER unit is now ready to receive a transmission from your POOLGUARD unit. DO NOT USE YOUR REMOTE RECEIVER OUTDOORS. 0----------- SWIMMING POOL SAFETY TIPS • Supervise children at all times. • Never permit swimming alone. Never leave a child alone, even to answer the telephone. • Always remove the entire solar cover from a pool before swimming. • Remember that alcohol and water safety do not mix. • Have your pool area fenced and the gate locked to prevent unauthorized entry to the pool, and install a gate alarm. • Lock and secure all doors in the house which permit easy access to the pool, and install a door alarm. • Have a responsible adult teach swimming and water safety to your children. • Maintain clean, clear water in the pool. • Do not swim during electrical storms. • Do not permit bottles, glass, or sharp objects to be used around the pool. •Ask your pool dealer how you can improve your pool safety -they will be glad to assist you. •Above all: remember that common sense, awareness, and caution will allow you to enjoy your pool. WARRANTY AND REPAIRS POOLG UARD is sold with a limited warranty to cover defects in parts and workmanship for three years from date of purchase, (retain proof of purchase). If POOLGUARD exhibits a defect, please call Customer Service at 1-800-242-7163. Unauthorized returns will not be accepted. Proper repair is only ensured when the unit is returned to the manufacturer. SEND CORRESPONDENCE TO: PBM INDUSTRIES, INC. P.O.BOX 658, NORTH VERNON, IN 47265 1-800-242-7163 This product has been designed to aid in the detection of unwanted intrusions into unsupervised pools. POOLGUARD IS A SAFETY ALARM SYSTEM AND NOT A LIFE SAVING DEVICE. ''This device is not intended to replace any other safety consideration -i.e., adult supervision, lifeguards, fences, gates, pool covers, locks, etc., and some devices may not detect gradual entry:' REV. 10/2007 -----------• HELPFUL HINTS AND TROUBLESHOOTING Poolside Unit roolguard® Powdool, FALSE ALARMS All pool alarms will false alarm on occasion for different reasons. False alarms can be minimized; however, it is important to remember that a false alarm is better than no alarm at all. WEATHER & WIND-POOLGUARD sets stationary on the deck of the pool so the wind will not effect the alarm unit itself. Wind may trigger a false alarm if it is strong enough or steady enough that it causes the water in the pool to rock or bounce up and down the pool wall. When the water in the pool moves up and down the POOLGUARD sensing throat, it may finally cause the alarm to sound. On extremely windy days when the pool water is rocking it is advised to remove the POOLGUARD from the pool. Light wind or rain will not effect the POOLGUARD alarm. Another false alarm occurs when the pool owner tries to install the alarm too soon after swimming. After swimming, the water in the pool will rock or bounce up and down the pool wall for some time depending on the size of the pool and the type of swimming activity. Before installing the alarm, after swimming, the pool must be given time to calm. Time will vary (around 10 to 30 minutes); once the pool owner sees that the pool water is no longer rocking up and down the pool wall, it is time to install the alarm. Certain automatic cleaners may set the POOLGUARD unit off in some cases. If the cleaner head or the cleaner hose hits the POOLGUARD alarm it may cause it to false alarm. Solutions to this problem are to use your cleaner at night and your alarm during the day. Another option would be to find a place around the pool where the cleaner does not interfere with the alarm. Certain water features such as waterfalls can cause POOLGUARD to false alarm. To avoid this problem do not install the POOLGUARD alarm too close to the water feature. If you are having a problem with any type of water feature call POOLGUARD at 1-800-242-7163. •----------- ALARM PLACEMENT The alarm should be on a flat, solid surface for best results. The throat of the unit is designed to work in most pools with an in-wall skimmer. The water level up on the throat is important and should be checked. The sensing throat cannot be less than 2 inches in the water, and not more than 7 inches into the water. POOLGUARD recommends that the sensing throat be approximately 4 inches in the water. POOLGUARD can be used with a solar cover; however, before removing the cover, the alarm should be taken out so it does not get pulled into the pool. ALARM TESTING Drop something of approximate size, weight and volume of the families smallest child, the farthest point away from the alarm. A four (4) gallon jug of water or 3 one (1) gallon jugs of water tied together are ideal for testing. Remember, when testing you must wait about 15 minutes between tests for the pool to calm. ALARM WILL NOT SOUND Be sure that a 9 volt battery has been installed properly. If you are testing and POOLGUARD does not alarm, be sure you are testing properly- putting your feet in the pool, splashing with your hands, making waves with a leaf skimmer, or dropping something into the pool that does not have the proper size, weight and volume will not set the POOLGUARD alarm off! Testing is very important and should be done correctly. CARE AND HANDLING POOLGUARD is made of sturdy, rigid vinyl PVC -UV rated. Because the alarm is electronic and mechanical great care should be taken not to drop the unit; like any other appliance, it may break. Sun and rain will not hurt the alarm. POOLGUARD is water resistant but not waterproof. Great care should be taken not to knock the alarm into the pool. If the alarm goes into the pool there are directions in the manual on how to dry it out, but more than likely it will have to be returned to the factory for service. Always remember to remove the alarm before using the pool. -------------• REMOTE RECEIVER When the unit at the pool alarms, the remote receiver will sound. Maximum Range for the remote is 200 feet from the poolside unit. Avoid placing remote in basements or close to metal walls. Be sure that the red light on the remote is on. Remember the poolside unit must be beeping (alarming) for the remote to work. If your remote receiver is not getting a clear signal or no signal from the poolside unit, try the following: Before plugging in the power supply, be sure to stretch out the cord; do not leave it tied in a bow as packaged. When you first plug in the remote it will give one short loud beep then stop. Your Remote Receiver is similar to a small portable radio. If your remote is not sounding when the poolside unit is sounding-move the remote to different locations and stand back for a few seconds for the remote to pick up the signal. You may only have to move your remote a little to the left or right to bring in the signal-in some cases you might have to move the remote to a different location or another room. If you cannot get a signal on your remote receiver CALL CUSTOMER SERVICE AT 1-800-242-7163 •----------- QUICK DO'S AND DON'TS • DO read the manual carefully • DO install a 9 volt battery • DO untie the bow on the power supply • DO test the alarm properly • DO carry your alarm by the handle • DO remove alarm before swimming • DO hold on to your red customer service card with our 800 service number • DON'T leave alarm in pool while swimming • DON'T drop your alarm, it may break • DON'T knock or let your alarm fall into the pool • DQN'T jnstall your alarm immediately after sw1mm1ng • DON'T use your alarm on extremely windy days -----------e Cover page 325 Country Club Atlantic Beach FL 32233 Occupancy class R-3 FBC 2017 NEC 2017 1.Impervious calculations (Please refer to the Topo survey attached) 2.Building Permit Application 3.Proof of ownership (this customer has a sealed record and information cannot be accessed) 4.Notice of Commencement (to be filed) 5.Site survey 6.Site management plan 7.Site plan 8.TDH worksheet 9.Drain and entrapment prevention 10.Pool steel drawings 11.a-g equipment cut sheets 12. Alarm specifications POOL20-0032 ~ fool~ LLC CLEAR & CLEAR® RP CARTRIDGE FILTER Efficient and carefree ... by design The Clean & Clear RP f i lter's innovative s ide entry desi g n opti m i zes f low for greater en er g y effic iency. It features an easily-clea n ed cartridge for the u ltimate i n carefr ee pool fi ltration . T he f iber g l ass-reinforc ed tank h alves a r e se cured with a low-force c lam p r i ng-just l oosen the r in g and r emove the top hal f f o r easi er cartridge access and r i nsing. Fil ter mainten ance doesn't get any easi er. KEY FEATURES Single-piece base and tank Constructed of fiberglass-reinforced po ly propyl ene for strength, chem ical r es istance and max imum durabili ty. High Flowr" manual air relief valve Rel ief valve and continuous internal air relief work together to maintain optimum filtration efficiency. 1-1/2" drain cap and washout For quick and conven ient mai ntenance and winterization. Innovative lock-ring Requ i res onl y an easy half of a revolution for a leak-proof seal. Easy access 1-1/2" drain 2" x 2-1/2" plumbing For maximum f low; innovative side ent ry maximizes energy effici ency. Low-force clamp ring Opens and closes easily for quick access to cartridge. Easy to remove and rinse cartridge Fo r near effortless clea ning. Quick-connect union Qu ick-connect union with diamond seal assures easy installation and servicing. Unmatched hydraulic efficiency Nearly 50 % more energy efficient than other singl e cartridge filters. Model Filter Area Vertical Filter Flow Rate Turnover Capacity (Gallons) Number Sq. Ft. Clearance* Diameter CCR P 100 100 61' 15.5" l;CRP 150 150 CC RP 200 200 76" 15.5" ♦PENTAIR GPM 100 150 150 8 hrs. 10 hrs. 12 hrs. 48 ,000 60,000 72,000 72,000 90,000 108,000 72,000 90,000 108,000 "Requ ired clearance to remove filter elements The Clean & Cloa,. .. Cartridge Filter has ear"le•:1 the Eco Se ect• brand distinction as one of lhE" green est and most efficient choices :rom Pentair. 1620 Hawkins Ave I Sanford, NC 27330 I United States I 800.831.7133 I pentair.com All Pentair tradcm~rks and logos are owned by Penta:r pie, or one of its global affili ate s. Clean & Clear~. High -Flow111 and Eco Select$ vre trademark~ and/or registered trademar ks of Pen ta;rWater Pool and Spa, inc. and/or 'ts a~:liated co mpa'lies in the un:ted States and/or other countries. Because we are continuo1..c.ly moroving ou.- orooucts and services Penta r rese.-v es the rigtit to change soecification~ without prior notice. Penta ·r ·s an equa opportunity enployer. Pl-109 6/19 ©2019 Pentair Water Pool aod Spa. Inc. All rights reserved INTELLIFLO ®VSF VAR IABLE SPEED AND FLOW PUMP PRECISE FLOW CONTROL FOR THE HIGHEST ENERGY SAVINGS AND ULTIMATE SYSTE M PERFOR MANCE. PERFORMANCE CURVE S 100 I 90 Mox.SpHd @31.S0rpm 80 0 r.~ 70 0 S/ittd4 @ 110,pm u'. 60 E .,, "' "' 50 r. u '1§ 40 "' C: ,_ Speed3 - @Z350rpm C .. 30 ~ 20 • ... ··!,. t . I I Speed 2 @IS00rpm 10 I SpMd 1 @750rpm 0 I 0 20 40 ♦PENTAIR ---I I -.... .... I OPERATING RANGE FOR I r-.... FLOW CONTROL "-,...... r--.... ~ ...... r-... "-"- "-...... .......... ........ I"... .......... to-... ......... ""1.. ,, 1;;;_, • "'-. ./ ....... V 1, ......... .,,,. ----~ I .· i..---....- 60 80 100 120 140 160 Volumetric Flow Rate in GPM Oselect· The 1n1el'<Flo VSF Variable Speed and Flow Pump tias ea~ned ~he c.co Select• or and d s t 1nction as one-of the greenest and most effic·ent cho ces from Pentair. 1620 Hawkins Ave I Sa nford , N C 27330 I United St ates I 800.831.7133 I pentair.com TRADEGRA DE The TradcGrade taml'y c' prooucts ·s exct1,,slve.y rnaou for and sold by triP.worfd's most d emanding pool professionals. ENERGY STAR" Cert fed lntelliF O vs~ pumps <&ram Pentair meet strict energy-efficie'lcy cnerla set by t"e l:.S. Env:ronmental Pro1ection Agency acd :he U.S. Department of Energy. These pumps save money. raduce energy use a-id p~atcc: the environment. All Penta·, trade.arks aid logos ar~ owned oy Pentair pie. Intel 'Flo~ EasyT01,;ch" lnte liTouch~ Screen .. ogic2•ond ~co Se,ect• are ~egi'>tered uaoernarks of Penta r Water 0 001 and Spa ,re. and/or its atti iated compan·es in the Uriteo Sta:es anclor otrier covntries. Because we a~e co,tin..io..is yilY'pfov·ng OU" producrsa'"td serv·ce~ Penta·r r~servcs tlie right to ct-ange specif cations wi;:houi prior no:ice Pentair is an equal opportunity employer. Pl-413 2/19 ©20"9 Penu:"r Water Pool and Spa . Inc. A1 rights reserved. 8 c®• 7-3/4" NOVA POOL DRAINS :MP 2 55 13-26X, 255 13-4XX, 255 13-SXX, 255 13-6XX, 25 5 15-SXX, 2 55 16-26X ~55 16-4XX, 25516-SXX, 25517-SXX,25539-SXX,2 5539-6XX, 25548-SXX Read and keep these instructions for future reference. Fot Mottiplf: Or.in U.s-Orly Su~ 1.S-,.11 8 GPMCW.J0 / 140Gl>M~ r-11aGPM(Wal)/ ISOGPM(floo,) Lle::7Yffl1 ,,_,,,_ \tGB:2008 COMellA"'NT Always plumb and install all suction fittings according to all building codes that apply in your area. NARNING: The suction fitting and fasteners should be inspected for damage or tampering before each use of the faci lity. If t he fitting/cover breaks, is damaged, or is 11issing, shut the system down immediately. Missing, broken, or cracked suction fittings must be replaced before using t his faci l ity. Use of the system w ith damaged, oose, or missing covers may resu l t in serious injury or death. NARNING: Never exceed the maximum allowable flow rate stated on the suction fitting. In the event that one suction outlet is completely blocked, the remain ing ;uction outlet(s) serving that system MUST have a flow rating capable of the full flow of the pump(s) for the specific suction system. :AUTIO N: Children should never be left unattended at any time i n a swimming pool, spa, or bathtub. Be sure t h e temperature of the w ate r never exceeds the nanufactu rer's recommendations. -he maximum flow rating for this suction fitting with 1.s• plumbing is 118 GPM (Wall) and 140 GPM (Floor). The maximum flow rating for this suction fitting with 2· )lumbing is 118 GPM (Wall) and 150 GPM (Floor). This suction fitting is 40 .-----------------------------~ fosigned for installation on side wall or floor of hot tubs or pools in conjunc-~::~ ;~s~ :ion with at least one other suction fitting per pump. DO NOT adapt suction itting to any pipe size smaller than ASTM 1.s· SCH 40 PVC. Field built sumps 20 ;hould be constructed per ANSI/APSP -16 Figure 2 (see below) found on page ; of the Standard. Contact your local pool and spa professional for all vi£terizing instructions and recommendations. Open area of cover is 14.57 n . -ools Needed: Ph i llips Head Screwdriver NSTALLATION INSTRUCTIONS Install sump provided or construct sump per ANSI/APSP -16 Figure 2 (see below) If mounting frame is provided, secure it in concrete or plaster. Use mounting screws to secure cover to frame or sump. Omit\. Omln. A 8 0 GENERAl. NOTtS: (# D • Jnsidt clnettr ot plpt. (W NI di•asiOM &hown are mlntnufl'I.S.. (cl A brobn •• L _ J ~clC6ttS sltlllf'S,ltd sump ~bl. JSTALLATION NOTES: Mount suction outlets on t he wall o r floor. DO NOT locate suction outlets on Results may vary• lhls data Is provided for ,~r~rence only. REPLAC EMENT PARTS *Replace within 7 installed yea rs or immediately upon evidence of degradation or damage. •x• indicates color using digits 0-9, see catalog for color reference 25513-26X Sump 25513 -250-010 Plug 25513-250-020 Cover 25539-7XX-011 Screw 61004-083 -212 255 13-6XX Sump 25513-110-010 Plug 25520-050-010 Cover 25539-7XX-011 0-Ring 26100-580-355 Screw 61004-083-212 25516-4XX Sump 25516 -300-010 Extens ion 25516-000-020 Plug 25513-300-020 Cover 25539-7XX-01 1 Screw 61004 -083-212 25539-SXX Frame 25513-4XX 25513-SXX Sump 25513-300-010 Sump 25513-010-010 Plug 25513-300-020 Plug 25520-050-010 Cover 25539-7XX-011 Cover 25539-7XX-011 Screw 61004-083-212 O -Ring 26100-580-355 Screw 61004-083-212 25515-SXX 25516-26X Sump 25515-010-010 Sump 25516-250-010 Plug 25520-040-010 Extension 25516-000-020 Cover 25539-7XX-011 Plug 25513-250-020 Ring 25532-70X-000 Cover 25539-7XX-011 Gasket 25515-000-011 Screw 61004-083-212 Reducer 25520-020-000 Screw 61051-052-028 2 5516-SXX 25517-SXX Sump 25516-000-010 Sump 25518 -000-010 Extension 25516-000 -020 Cov er 25539 -7XX-011 Plug 25520-050 -010 Screw 61050 -048-025 Cover 25539-7XX-01 1 O-Ring 26100-580 -355 Screw 61004-083 -212 25539-6XX 25548-SXX Cover !ating areas or on backrests for seating areas. Screw Always use multiple suction outlets. DO NOT use with si ngle drain applications. 25539-000-020 Frame 25539-7XX -011 Cover 6 1004-083-212 Screw 25539-100-010 Ring 25539-7XX-011 Cover 61054-048-019 Screw 25532 -70X-000 25539 -7XX-011 61004-083-212 se w ith single drain appl ications will void any and all warranties. When using two or more suction fittings on a common suction line, suctions must be separated by a m inimum of 3 ft or they must be located on two different anes (i.e. one on floor and one on the w all). To reduce the risk of drowning from hair and body en trapment, install suction fittings with a marked flow rate in gallons per minute t hat exceeds the flow rate of >Ur system by at least 25%. Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing ent r apment or death. CMP drain covers are only certified for use with CMP sumps and frames. Do not mismatch with parts from other manufacturers. &DANGER Hair or body parts blocking the spa o r pool suctions may become trapped and held aga inst the suction fitting. Keep hair and clothing a minimum of 12 inches from all suction fittings and drains a t all times. Entrapment against the su ction fittings can result in drowning or o ther severe injury. N ever sit on or lean up against suction fittings. ·713sb CUSTOM MOLDED PRODUCTS I 36 HERRING ROAD, NEWNAN, GA 30265 I WWW.C-M -P.COtv MASTERTEMP ® HIGH PERFORMANCE HEATER Make the move toward greater comfort and efficiency. Learn more from your Pentair dealer or visit pentair.com. POOL SIZING" Heater Size OF Temperature Model Model Model Model Change/ 175 200 250/250HD 300 24 Hrs. Pool Capacity in Gallons 5 85,210 97,383 121,729 146,075 10 42,605 48,691 60,864 73 ,037 15 28,403 32,461 40,576 48 ,692 20 21,303 24.~6 30,433 36,519 25 17,042 19.477 24 ,346 J 9,216 30 14,201 16,230 20,288 24 ,345 35 12,173 13,912 17,390 20,868 40 10,651 12,173 15,216 18,260 *ASME models ava ilable. See you r Penta ir represe nt at ive for details. SPA SIZING" Model Model 400/400HD 175 194,766 2,0 69 97,383 1,034 64 ,922 690 48 ,691 517 38 ,953 414 32 ,461 345 27,824 296 24 .346 259 Spa Volume (Gallons) Model 200 300 400 500 600 700 Heater Size Model Mode l Model Model 200 250/250HD 300 400/400HD Pool Surface Are a in Sq. Ft. at 5.5' Depth 2,364 2,955 3,546 4,727 1,182 1,478 1,773 2,364 788 985 1,182 1,576 591 739 887 1. 182 473 591 710 945 394 493 591 788 338 423 507 675 295 369 443 591 800 900 1,000 Minutes for 30°F Temperature Rise (Heater Input in 1,000 BTU/HR) 175 21 31 40 50 61 200 18 27 35 44 53 250/250HD 16 24 31 39 47 300 14 20 27 33 40 13 18 22 2 *N ote ; The chart is base d on a 30°f (16.6°G ) temperoture rise, discounting losses and only based on heat require d to raise temperature in mi nutes. Two-year limi te d warranty. Se e warranty for details. ♦PENTAIR 71 62 54 47 1620 Hawkins Ave I Sa nford , NC 27330 I United States I 800.831.71 33 I pentair.com 81 91 10 2 71 80 89 62 70 78 53 60 67 35 ~ Th e MasterTemp ffqh Performance Heater has earned tne Eco Select• brand distinction as one of the greenest and most eHicient choices from Pentai r. TRADEGRADE The TradeGrade family of products is exclusively made for and sold by the \'/Orlds most de:nanding pool professionals. All Penta:r trademarks and logos are owned oy Pentair pie, or one of its global affiliates. MasterTemp• and Eco Select" are registered trademarr<s of Pentair Water Pool and Spa Inc. and/or its affiliated compc:nics in the United Sta:cs and/or other countries. Because we are continuously improving our products and services. Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. Pl-00410/19 ©2019 Pentair Water Pool and Spa. Inc. All r,ghts reserved. @• ® FLOW THRU SPA NOSKIMMl!R SKIMMER TYPICAL GR. FOR# J Rl!BAR, 2' OlJI" WITH #8CUTOPUMJ' ~------'--''--_____ ..,__._ ____ ~<-..----, OPTlONAL DECK W/ I ~" l'ITCH IN lO' OPTIONAL 12V LlGIIT W/TRANS. ¾" BRASS OR rvc (SEE NOTES) SWIM-OUT OR LADDER REQUIRED (GR/#8 CU) WHl!RE DEPTII OVl!R 5' DEEr (SEE NOTES) NO LIMITATIONS TO SHAPE EXCEPT FOR DNING ENTRY REQUIRED (SEE NOTES) RAIL OPTIONAL GENERAL POOL PLAN WATER LINE EXCEPTlON: ROPE AND FLOATS INSTALLED lF LESS THAN 4'-o" N.T.S. 2'-9" Min. EXCEPT FOR SLOPING ENTRIES. 4'-0" Max. SEE NSPI 5 RE: HANDHOLDS 8' Min. TO SLOPE CHANGE POOL SECTION DETAIL N.T.S. 11.0"Max. SB2836, 6-20-07 FOR BONDING AND GROUNDING SYSTEMS FOR SWlMMING POOLS, THE USE OF AN UNDERGROUND BONDING CONDUCTOR MADE OF #8 AWG. BARE SOLID COPPER WlRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUBGRADE, AND 18 TO 24 INCHES FROM INSIDE WALL OF A SWIMMING POOL OR SPA, IS DEEMED A PERMlSSIBLE ALTERNATIVE OR EQUlV ALENT TO COMPLIANCE WITH s. 680.26(c) OF THE NATIONAL ELECTRJCALCODE. PAVERSOR 4" DECK 2,500 psi (Min.) CONC. W/FIBER MESH DECKHNISH PER CONTRACT (NON-SUP) 8"-<---+-~J----POOL FINISH '--'-+--8" X 8" FOOTING W /(2) #3 BARS BEAM & "7" BAR OPTIONAL OR())#S BAR 611-,I<-+--¥ 6" Min. WALL & FLOOR THICKNESS. 3,SOO psi (MJN.) CONC. #3 BARS ON __J 12"CENTERS EITHER WAY, TIE ALT. lNTERSECTIONS 15" MJN. OVERLAP. 2" MTN.COVERAGE ON STEEL W/CONC. TO ASTM AIS. A16. ASTM AJ0-5 Structural subject to suitable soil conditions. PER CONTRACT FINISH¾" MARCITEOR EXPOSED AGGREGATE POOL/SPA, DECK, BEAM, WALL, FLOOR N.T.S. RAIL OPTIONAL > MAIN DRAIN Rl!QUlRE (TAMPER PROOF/SEE NOTES) >LIGHTING & BONDING SAME AS POOL >NO LIMITATIONS ON SHAPE FLORIDA BUILDING CODE R4501 THE POOL CONTRACTOR IS RESPONSIBLE FOR FURNISHJNG ALL DETAIL DESIGN REQUJREMENTS FOR EACH INDIVIDUAL POOL IN ACCORDANCE WITH THE FLORJDA BUILDING CODE, AND ALL CONSTRUCTION SHALL MEET ALL APPLICABLE CODES INCLUDING PLUMBING, ELECTRICAL AND GAS. PIPING SHALL BE SCH. 40 PVC, NSFpw, MAX. PRESSURE VELOCITY 10 FPS, sucnoN 6 FPS. THE POOL PLAN SHALL SHOW THE DESIGN PLUMBING AS PER THE SAMPLE WITH THE INFORMATION REQUlRED SHOWN. MAlN DRAIN PLUMBING SHALL BE TWO DRAINS SEPARATED BY 3' WlTH APPROVED ANSJ/ASME Al 12.19.8.2009 COVERS. AS AN AL TERNA TE THE APPROVED DRAINS MAY BE PLACED ON DIFFERENT PLANES. THE TWO DRAINS SHALL HA VE A COMMON SUCTION LINE. SUCTION GRATES MAY BE USED IF APPROVED AT A MAXIMUM OF I ½ FPS AND THE SUCTION PIPING JS RECESSED FROM THE GRATE THE DISTANCE EQUAL TO THE SUCTION PIPE SIZE. SKIMMERS DO NOT REQUIRE PROTECTION AND MUST BE DESIGNED FOR A MINIMUM 25 gpm. GENERAL SP A PLAN N.T.S. THE FOLLOWING SHALL BE LABELED WITH LABEL MARKER TAPE AT THE FILTER LOCATION: PIPES, VALVES, PUMP(S) OFF SWITCH. ELECTRICAL REQUIREMENTS: -WlRING AND BONDING AND ALL ELECTRICAL TO COMPLY WITH CHAPTER 42, FLORJDA BUCLDING CODE 6TH EDITION-RESIDENTIAL AND NEC 2014. -NO OUTLET OR OVERHEAD POWER WITIUN 10' IF WITHIN 15' PROTECT BY GFI, TRANSFORMER MIN. 10' FROM POOL, 8" ABOVE WATER. J BOX 4' FROM POOL, BRASS TO J BOX OR TRANSFORMER WHJCH EVER IS FIRST EXCEPT WHERE PVC JS APPROVED. SAMPLE ONLY. EACH APPLICATION FOR PERMIT SHALL BE BASED ON A TOT AL DYNAMIC HEAD OF 60 ft. Determine System Flow Rate: Minimum Flow Rate Required: 351,'Pln per skimmer (Required: I Skimmer per 800 sf) Pool Volume: _2.QQ__ sq. ft x_4 __ ave depth x 7.481 gal/cf= 15,000 Turnover Time in Hours: l-bours x 60 min/br =~minutes Flow Rate: 15.000 gallons/ ....3.filL_ minutes = _42_ gpm PlPE SIZING CHART <MAXlMUJ:!l ~ .fil&I!.Q!:! PRESSURE I½" JSGPM 65GPM 2" 60 105 2½ 90 l47 3" IJS 230 4" 235 396 FOR POOLS WITH VOLUME •I 5,000 GALS. PUMP: STARITE P6E6DL OR HAYWARD SUPERU ¾ HP 42 GPM 60' TURN TURNOVER RATE•6 HOlJRS•360MINS. FILTER: STARITE PTM 50,50GPMOR HAYWARD C751, 75 GPMCAPACITY MAIN DRAIN: HAYWARD W610481! CLEANER: HAYWARD VAC LOC MAIN SUCTION PIPE SIZE __.2'.'.. SKIMMER SUCTION PIPE SlZE _2'.'.... CLEA NERN AC PIPE SIZE Ji:_ RETURN SUCTION PIPE SIZE ~ EQUlPMENT LOCATION gallons • MAIN DR.AINS AS OF l2-l9-08 ANSVASMEAI 12. 19.8-2007 POOL MIN. GRATE OPEN ARl!A • FLOW/l7.8 FOR VELOCITY 6'/SEC CLEANER LINE RESIDENCE SPECIAL SPA REQUIREMENTS: -MAXIMUM WATER DEPTH 4', MAXIMUM SEAT DEPTH 28",MAX. -FLOOR SLOPE 1:12 -STEPS: MTN. TREAD 10" X 12", 7" MIN. RJSER, 12" MAX. RJSER EXCEPT THE BOTTOM STEP MAY BE 14" IF IT IS THE SEAT. INTERMEDlA TE TREADS AND RISERS TO BE UNIFORM. IF THE SPA IS OPERA TED INTERMITTENTLY IT SHALL HA VE A ONE HOUR TURNOVER, IF CONTINUOUS A SIX HOUR TURNOVER. -MAXlMUM TEMPERATURE I 04 DEGREES. -MEET ANSI/NSPI ARTICLE XVII, SAFETY INSTRUCTION/SAFETY SIGNS. -PRESSURE TEST PIPING AT 35 PSI FOR 15 MINUTES OR MEET LOCAL CODE IF GREATER. GENERAL DESIGN REQUIREMENTS -DESIGN, CONSTRUCTION AND WORK.MANSHIP SHALL BE IN CONFORMITY WlTH THE REQUlREMENTS OF APSP/ICC 3, APSP/ICC 4, APSP/ICC 5, AND APSP/ICC 6 AND APSP/ICC 7 BASED ON THE POOL TYPE. -SEE NSPI FOR DIVING WATER ENVELOPES. -SLIDES SHALL MEET THE MANUFACTURE'$ INSTALLATION REQUIREMENTS. -ALL POOLS WHETHER PUBLIC OR PRJV A TE SHALL BE PROVIDED WITH A LADDER OR STEPS IN THE SHALLOW END WHERE THE WATER DEPTH EXCEEDS 24 INCHES (610 MM). IN PRJV A TE POOLS WHERE :,V ATER DEPTH EXCEEDS 5 FEET ( 1524 MM) THERE SHALL BE LADDERS, ST AlRS OR UNDERWATER BENCHES/ SWIM-OUTS IN THE DEEP END. WHERE MANUFACTURED DIVING EQUIPMENT IS TO BE USED, BENCHES OR SWlM-OUTS SHALL BE RECESSED OR LOCATED IN A CORNER. -CIRCULA TlON SYSTEMS, COMPONENTS AND EQUIPMENT SHALL COMPLY WITH NSF 50. -TIIE MAXIMUM TURNOVER RA TE lS 12 HOURS. -FILTERS SHALL HA VE AN AIR RELEASE AND PRESSURE GAGE. -PUMPS 3 HP AND LESS SHALL MEET ANSI/UL I 081 CORROSION RESISTANT WITH STRAINER AND MEET THE REQUIRED FLOW. -SURFACE SKIMMERS SHALL MEET NSF 50 AND THERE SHALL BE ONE FOR EVERY 800 SQUARE FEET OF SURFACE AREA. -APPROVED MANUFACUTRED lNLET FITTNGS FOR THE RETURN OF RECIRCULATED POOL WATER SHALL BE PROVIDED ON THE BASIS OF AT LEAST ONE PER 300 SQUARE FEET (28 m2) OF SURF ACE AREA. SUCH INLET FITTINGS SHALL BE DESIGNED AND CONSTRUCTED TO INSURE AN ADEQUATE SEAL TO THE POOL STRUCTURE AND SHALL INCORPORATE A CONVENIENT MEANS OF SEALING FOR PRESSURE TESTING OF THE POOL CLRCULA TION PIPING. WHEN MORE THAN ONE INLET IS REQUIRED, THE SHORTEST DISTANCE BETWEEN ANY TWO REQUlRED INLETS SHALL BE AT LEAST IO FEET (3048 MM). -HEATER SHALL MEET ANSI-221.56 OR UL 1261 OR UL559. -DISINFECT ANT EQUlPMENT SHALL COMPLY WITH NSF 50. -PRESSURE TEST PIPING AT 35 PSI FOR 15 MINUTES OR MEET LOCAL CODE IF GREATER. -RESIDENTIAL SWIMMING BARRIER REQUIREMENTS TO MEET SECTONS 454.2.17 -WASTE DISPOSAL TO COMPLY WlTH SECTION 454.2.10 IT HAS BEEN CERTIFIED THAT THESE DESIGN REQUfREMENTS ARE IN COMPLIANCE WITH THE FLORJDA BUlLDING CODE R450l, 6TH EDITON 454.2-2017, ANSI/APSP/ICC 3, ANSI/APSP/ICC 4, ANSI/APSP/ICC 5, AND ANSI/APSP/ICC 6 AND ANSI/APSP/ICC 7, ANSI/APSP/ICC 14, ANSI/APSP/ICC 15. ISLANDP N89°20'01"E115.15' (M)S00°40'38"E 150.08' (M) N00°41'50"W149.87' (M)S89°26'10"W115.10' (M)SPECIFIC PURPOSE SURVEY SURVEY OF:LOT 3, BLOCK 5, SUBDIVISION SELVA MARINA UNIT 2, ACCORDING TO THE PLATTHEREOF, RECORDED IN PLAT BOOK 27, PAGE 6-6A OF THE CURRENT PUBLICRECORDS OF DUVAL COUNTY, FLORIDAFOR:HOWE GROVERLEGENDGENERAL NOTES:1. THIS IS NOT A BOUNDARY SURVEY.2. BY GRAPHIC PLOTTING ONLY, THIS PROPERTY LIES WITHIN ZONE "X", AS SHOWN ON THE FLOOD INSURANCE RATE MAP,COMMUNITY PANEL NO. 120075 0409 J, (MAP NO. 12031C0409J), WHICH BEARS AN EFFECTIVE DATE OF NOVEMBER 2, 2018,AND IS NOT IN A SPECIAL FLOOD HAZARD AREA. NO FIELD SURVEYING WAS PERFORMED TO DETERMINE THIS ZONE.ZONE "X" DENOTES AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN.3. IMPROVEMENTS AND UTILITIES WERE NOT LOCATED AS PART OF THIS SURVEY, EXCEPT AS SHOWN HEREON.4. MEASUREMENT METHODS USED FOR THIS SURVEY MEET STANDARDS OF PRACTICE FOR LAND SURVEYING AS SETFORTH IN FLORIDA ADMINISTRATIVE CODE CHAPTER 5 J-17.050-.052 REQUIREMENTS.5. NO BEARINGS SHOWN HEREON. PLAT OF RECORD DOES NOT CONTAIN ANY ANGULAR INFORMATION.6. NOTE THAT PLAT DIMENSIONS ARE ONLY EXPRESSED TO THE NEAREST FOOT AND TO THE NEAREST MINUTE OF ANGLE.7. ELEVATIONS SHOWN HEREON ARE REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD-88), ANDARE BASED ON THE JACKSONVILLE TRANSPORTATION AUTHORITY ROADWAY PLANS, FINANCIAL PROJECT ID434343-1-58-02, BOX CUT IN SOUTHEAST CORNER OF CONCRETE BOX WEST OF INTERSECTION OF SEMINOLE ROAD AND9TH STREET, ELEVATION OF 7.18 (NAVD-88).8. ALL DATA SHOWN HEREON ARE FIELD MEASURED UNLESS OTHERWISE NOTED.9. THE PURPOSE OF THIS SURVEY IS TO SHOW THE TOPOGRAPHICAL FEATURE IN THE REAR OF THE LOT PER CLIENTREQUEST.FOUND 1/2" IRON PIPE IMPERVIOUS CALCULATIONS TOTAL AREA OF LOT EXISTING IMPERVIOUS AREA POST IMPERVIOUS AREA 17265.45 SQ FT 5756.33 SQ FT 33.3% 6659.54 SQ FT 38.5% DISTURBED x'b'."J tx NO ID x'b· ------------------------------------i.----~---'""'"''"""'""--""--""--'"'--,,;u=;,"'!'J3~LV~O -~--'!"'--""--""-""-!!!!--!!!!-!!!! __ '!"'_ !'!"!"!"!'!"!"!"!'!"!"!"~~=='1,~======71------------------------------------p 12 BAY 1x 'i, tx 'i, x'b· FOUND 1/2" IRON PIPE NO ID ~~r ><<o· x<c,· x<o· xct:,· ,,,....--~// TREE HOUSE 29 LVO (TO BE REMOVED) TBM #60012 X-CUT ON PORCH ELEV. = 9.26 [NAVD-88] 0 32 LVO WELL 0 16' PROPOSED x: POOL ELEV.~ 9 26 D 1325 TWO STORY WOOD FRAMED FFE=9.80 I r '()0 X I r ----j \.!&W x°''y / / / X xo/~,r--------..;., .,, ., TWO STORY GARAGE FFE=9.66 •,-,.J . DRll'.);:_WAY () 1x . o,'V o,'V., . ,,_J . . ., ., 0 • ,,_J ., .. ., ,,_J .. DRIVEWAY., 0., ,,_J ., . . ,,_J . A . . ,,_J ,., ., ,,_J • . . . DRIVE~AY ,,_J COUNTRY CLUB LANE TBM #601 MAG NAIL W/DISK "TRAV PNr" ELEV. = 7.42 [NAVO-BB] 60 ... RIGHT OF WAY tx o,· FOUND 1/2" IRON PIPE NO ID ~ 1" = 20' GRAPHIC SCALE 0 1 o· 20' DE DESIGN ELEVATION ELEV. ELEVATION ~ BENCHMARK ID. IDENTIFICATION 40' JOB No. 20-7 45 FILE No. A-250 PARTY CHIEF: J. PRATER F.B. 2073,PG38 DRAWN BY: T.HODGE CHECKED BY: J. THOMAS REVISION: NAVD NORTH AMERICAN VERTICAL DATUM LB LICENSED BUSINESS X##-# GROUND ELEVATION LVO LIVE OAK DATE: BY· SURVEY DA TE 09-23-2020 1------------+------,f-----. CAD Fl LE: P: \20\20-145 COAB 325 COUNTRY CLUB LANE FOR ISLAND POOLS\DWG\20-145-325 COUNTRY CLUB LANE-SPECIFIC PURPOSE.DWG GHIOTTO <l RSSOCIATES GHIOTTO & ASSOCIATES, INC. NA TIGNALL Y CERTIFIED SURVEYORS & MAPPERS CERTIFICATE OF AUTHORIZATION No. LB 6508 2426 PHILIPS HIGHWAY JACKSONVILLE, FLORIDA 32207 (904) 886-0071 (904) 886-7174 FAX WWW. GHIOTTO. com JOHN S. THOMAS P S.M. No. 6223 NOT VALID IMTHOUT THE SIGNA TUR£ AND THE ORIGINAL RAISED SlcAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER POOL20-0032~ Cl) < w~ <( w 3: (.) LL < 0 0:: I-0:: I ('.) ~ 0::: FNO 1/2" -o IRON PIPE p NO I.D l[) N ::.:: I-0 0 0 __J __J (D FNO i /2" IRO PIPE NO t.O w u w >-I u V1 r-z .. ::, wwo LL.,.,., y, d ': 0 ........ ,-..<( ~--0(0 0 O> ci O> l[) ~ z~ .... w·-, L,._ co au o-o::::: 3 o._ >->-"'-~ : 3: " :I"') o-l[) 0 en ;-ri 0 0 0 0 z z 35' 8 R.L. (PE" PLAT) 205 OO'(P) 205 22'(A) F D 3/4" IRON PIPE NO 1.0 MAP SHOWING FINAL AS-BUILT SURVEY OF LOT 3, BLOCK 5 AS SHOWN ON MAP OF SELVA MARINA UNIT NO. 2 AS RECORDED IN PLAT BOOK 27 PAGES 6-6A OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLA. CERTIFIED TO: WILLIAM HOWE GROVER, JR. / VICKEY J. GROVER SECTION 16, TOWNSHIP 2 SOUTH, RANGE 29 EAST 6' WOOD FENCE (114 O') N89.20'1 O"E N89"20'o1 •E NO i/2" I ON PIPE NO I 0. NORTH LINE OF SECTION 16 LO T 3 B L O C K 5 30.1' (8 80) co · .. 40.6 . .. -COVERED. ~~ ·.c?~CRET~ ·. o 39.5' ·m 2 4 TWO STORY N 2 4' HARDIE BOARD ~ ~.. RESIDENCE a:: o._ 0 5 'i. u ~ CJ ADDRESS #32 8 <J' _() ~ F.F.E.=(9.84) COVERED CONCRETE ·o ENTRY N ·1~ ·1 \ ·1 W 1--I I u l/1 1-z w::::) I c., 3 o c..-l/1 " -I I 9 7· ,---""'2"""4""'2,..· --,7,9·: . ,n 0 . 0 ;.,; . · . -... TWO STORY a:!<.: ~ GARAGE . 5 HARDIE ~ 5 BOARD N u • 032.4' I ·1 N OJ ·. ·_·. . (9 20}1 CONCRETE 1 " 10.0· DRIVEWAY · W/BRICK IMPRESSIONS ' 32.3' I.LI w : 32.0' 40.2' -,_.....rrx-+-cH--J<--><-><-~o~--~5~.~-~-'.",'C~O~V~EoRE~D~7,-J '-"· CONCRETE (0 0 .... l[) ·"N .. en w u z w~ u..Q o"'l o_ o~ 3 o._ >-w-lf) s:t-::.:: w I-0 I-I-W V1 a::w 0 u;; 0 z-oro uo _j __J (D DENOTES FOU O 1 /2" 0 IRON PIPE 0 I 0 UNLESS OTHERWISE NOTED (CY-DENOTES CONCRETE POWER POLE ATRB -DENOTES AT&T RISER BOX CRB -DENOTES CABLE RISER BOX --------------------':';:.::. 25 o· --z: 0 9 4' 6.4' ;-t'1 a (0.00) -DE OTES TOPOGRAPHIC SPOT EL[VATION (GROUND SHOT) 72~ PLASTIC GAS LIO (BEARING BASE) <s.5oJ s89·20·1 o"w sa9·20·1 o·w CONCRETE LEAD WALK C,,I "' =--t 115.00' P 13.1' CJ 0 0 0 VJ (/) FNO 1/2" l''ION PIPE NO I 0. 115.05'(A) c_~ ADDED CERTIFICATIONS; 06-12-17 (OFFICE) FINAL; W.O.# 156168; 06-01-17 (FIELD) LOT & HOUSE STAKE OUT (GOOD-SET F.F.E.); W.0.# 151389; 08-29-16 (FIELD) BOUNDARY; TOPOGRAPHIC; PLOT PLAN; TREE; W.0. # 151163; 08-18-16 (FIELD) MORTGAGE; W.O. # 151163; 08-18-16 (FIELD) THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE COMMITMENT. THERE MAY BE ADDITIONAL EASEMENTS ANO/OR RESTRICTIONS THAT ARE NOT SHOWN ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY. UNDERGROUND ENCROACHMENTS NOT LOCATED ---------.-OH ----;::c;;c:c;-;;,-;:;=;-;:7rrm,::---OH -----------:-;-' 0 OVERHEAD ELECTRIC ,_: A TRB THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE •x• AS SHOWN a:i CURB & GUTTER COUNTRY CLUB LN ( 16 TH STREET PER PLAT) (60' RIGHT OF WAY) BENCHMARK: FND 60d NAIL IN POWER POLE IN FRONT OF THIS LOT ON WESTERLY SIDE ELEVATION: (10.00) ~ ELEVATIONS SHOWN HEREON ~ REFER TO NAVO OF 1988 ON FLOOD INSURANCE RATE MAP 0409 H FOR CITY OF ATLANTIC BEACH. DUVAL COUNTY, FLORIDA, F.1.R.M INDEX DATE 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. I.AND SURVEYORS -3751 SAN JOSE PI.N:£. SUfTE 15 -JACKSO/MU£, FLORIDA, 32257 -904/279-0088 -UCENSBJ I.AND BUSINESS NO . .J857 CONC MON. 1.P. LR. CH A R (C) (D) !~l 'i. R/W (A) (W) F.B. = CONCRITT = MONUMENT = IRON PIPE -IRON ROD • CHORD • ARC LENGTH ::: RADIUS = CALCULATED -DEED • PLAT -RADW. • CENTER LINE : RIGHT -OF-WAY • ACTUAL = WITNESS SKETCH P .R.M. • PERMANENT REFERENCE MONUMENT P.T. • POINT OF TANGENCY P.C. • POINT OF CURVE P.R.C. -POINT or REVERSE CURVE P .C.C. • POlt-lT OF COMPOUND CURVE 8.R.L • BUILDING RESm1cnoN UN[ F,P .&:L.= FLORIDA POWER & LICHT A/C = AJR CONDffiONER LO. IOENTIFlCATION NGVO • NATIONAL GEODETIC VERTICAL DATUM NAVO • NORTH AMERICAN VERTICAL DATUM P.1. • POINT OF INTERSECTION EW • EDGE OF WATER TOB ::::c TOP OF BANK LB = LICENSED BUSINESS o.c. ____ _ THE ABOVE LANDS WERE SURVEYED UNDER MY RCSPONSIBL£ SUPERVlSION ANO DIRECTION, THAT THERE ARE NO ENCROACHMENTS EXCEPT AS SHOWN AND THAT THE SURVEY SHOWN HEREON MEETS THE MINll,AUM TECHNICAL STANDARDS SET FORTH BY THE '1.0RIOA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS PURSUANT TO CHAPTER 472.027 / CHAPTER 61G17-6, '1.0RIDA. STATUTES. SURVEY NOT VALID UNUESS EMBOSSED BYS 0. HARRISON, SCALE 1 "=30' DATE 07-26-16 -::-5 =-4 POOL20-0032FOUNO I /2" IRON DIPE NO 10 O 32 _vo <f6' PROPOSED • POOL D (LEV •9 26 S89°26'10"W 115.10' (M) TWO STORY GARAGE ITT=9.66 • .. . ., . .···4 .. .,.i .. · .•: . ., ... 17265 45 SO FT 5756.33 SO FT 33.3% 6659.54 SO FT .38.5% i:.Ll ,-.. ~6 ,.... o co vo 0 • . _ . ..,.· .·. oO OV) ... ·.,.i . . . 4 •<Ql,.•.••,f ..,.,, VJ -ORIV[~IAY .,. .,. ; .. •' ... .. DRIV(.~A Y. . . ,J .. .. FOUND 1/2" IPON PIPE NO ID COUNTRY CLUB LANE TEN #601 Mt,G NA L W/0,~K "TRAV Pt'H" ELEV -7.•2 [NAW-88] 60' RIGHT OF WAY 0 f£ 1" = 20· GRAPHIC SCALE 10' 20' GENERAL NOTES: SPECIFIC PURPOSE SURVEY SURVEY OF: LOT 3, BLOCK 5, SUBDIVISION SELVA MARINA UNIT 2, ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 27, PAGE 6-6A OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA FOR: HOWE GROVER LEGEND DE DESIGN ELEVA TIO'! l~AVD NORTH AMERICAN ELEV. ELEVATION VERTICAL DA TU~1 $ BENCHMARK LB LICENSED BuSINESS xfi#./1 GROUl~D ELEVATION ID. IDEldlrlCATION LVO LIVE OAI< 40' 1. THIS IS NOT A BOUNDARY SURVEY. 2. BY GRAPHIC PLOTTING ONLY, THIS PROPERTY LIES WITHIN ZONE "X", AS SHOWN ON THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 120075 0409 J, (MAP NO. 12031C0409J), WHICH BEARS AN EFFECTIVE DATE OF NOVEMBER 2, 2018, AND IS NOT IN A SPECIAL FLOOD HAZARD AREA. NO FIELD SURVEYING WAS PERFORMED TO DETERMINE THIS ZONE. ZONE "X" DENOTES AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. 3. IMPROVEMENTS AND UTILITIES WERE NOT LOCATED AS PART OF THIS SURVEY, EXCEPT AS SHOWN HEREON. 4. MEASUREMENT METHODS USED FOR THIS SURVEY MEET STANDARDS OF PRACTICE FOR LAND SURVEYING AS SET FORTH IN FLORIDA ADMINISTRATIVE CODE CHAPTER 5 J-17.050-.052 REQUIREMENTS . 5. NO BEARINGS SHOWN HEREON. PLAT OF RECORD DOES NOT CONTAIN ANY ANGULAR INFORMATION. 6. NOTE THAT PLAT DIMENSIONS ARE ONLY EXPRESSED TO THE NEAREST FOOT AND TO THE NEAREST MINUTE OF ANGLE . 7. ELEVATIONS SHOWN HEREON ARE REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD-88), AND ARE BASED ON THE JACKSONVILLE TRANSPORTATION AUTHORITY ROADWAY PLANS, FINANCIAL PROJECT ID 434343-1-58-02, BOX CUT IN SOUTHEAST CORNER OF CONCRETE BOX WEST OF INTERSECTION OF SEMINOLE ROAD AND 9TH STREET, ELEVATION OF 7.18 (NAVD-88) . 8. ALL DATA SHOWN HEREON ARE FIELD MEASURED UNLESS OTHERWISE NOTED. 9. THE PURPOSE OF THIS SURVEY IS TO SHOW THE TOPOGRAPHICAL FEATURE IN THE REAR OF THE LOT PER CLIENT REQUEST. JOB No 20-145 FIL£ No. A -250 PART>' CH/FF-J. PRATER F.B. 2O73,PGJB DRAWN BY: THODGE CHECKED BY: J. THOMAS REVISION· DAT£: BY: SURVEY DA TE 09-23-2020 1------------+------+----a CAD FILE: P:\20\20-I45 COAB .325 COUNTRY CLUB LAN[ FOR ISLAND POOLS\DWG\20-145-325 COUNTRY CLUB LANE-SPECIFIC PURPOSE.DIVG GHIOTTO d ASSOCIATES CH/OTTO & ASSOC/A TES, INC. NA TIGNALL 'r CERTIFIED 5URV£YORS & MAPPERS CERT/FICA T[ OF AU THORIZA T/ON No. LB 6508 2426 Pl-I/LIPS HIGHWAY JACKSONVILL/:, FLORIDA 32207 (904) 886-0071 (904) 886-77 74 FAX w ww. CHIO TTO. com JOHN S. THOMAS P.S.M. No. 6223 NOT VALID WITIIOUT TH£ SIGNA TUR£: AND TH[ OR/iJ/oVAL RA/S£:0 SE:AL OF A FLORIDA LICENSED SURVE:YOR AND MAPPER POOL20-0032 Revision Request/Correction to Comments City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: {904) 247-5826 Email: Building-De pt @co ab.u s · 0 Revision to Issued Perm it OR D Corrections to Comme nt s **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. PERMIT#: _______ _ Date : f l -@-""UY Project Addres s: _3..,_,d.L..>.-S...,___,(..__o=u.L.!..::,v"-\~r:.__,~,_/----'C""--'-\ =u=b:c__ _______________ _ Contractor/Contact Name: _]?._.__;,,t)"'--....:(.,~r""'°'"....,f,__ _________________ ---'----------' Contact Phone : 3 "3 L\ ~ ::\ d: \ Description of Proposed Revision/ Corrections: U pJ <t,-..k .J bee,, IJc.t 'jL / lde:kvh ~ cJ,V } liJ<lS ,-Orv f I c, µ I_J:-+=:.......:.D-=--_,G..L.:..r_..4'--I-'(=--------affirm the revision/correction to comments is i nclus ive of the proposed changes. (printed name) ~posed rev ision/corrections add additional square footage to original submittal? V 0 Ye s (additional s.f. to be added: ____________ ) ~roposed revision~c_orrec:ions ad~ addi_ti~nal increase in building value to original submittal? ~ C:J*Yes (add1t1onal increase In building v alue: Contracto r must sign if i ncrease in va luation) *Signature of Contr actor/ Agent:~,..=-----,-£----------------- (Office Use Only ) ~pproved D Denied D Not Applicable to Department Permit Fee Due $ _____ _ Revision/Plan Re v iew Comments ____________________________ _ Department Review Required: Building Planning & Zoning Tree Administrator Public Works Public Utiliti es Public Safety Fire Serv ices Reviewed By }n 9 Date Updated 10/17/18 IMPERVIOUS C,\LCvLA TIOMS 4 '111l\ 11l4'lllil\ fiGilriliGillil\ /ili4GilGil TOTAL AREA OF LOT FOUND u 1~~lll/J01!1 U@i!!I u u:.wg,11.!i"IW UrJJt EXISTING IMPERVIOUS AREA 17265.45 SO FT 5 756. 33 SQ FT .,3 .>% 1/2" IRON PIPE N89°20'0l "E POST IMPERVIOUS AREA 6659.54 SO FT 35 5% DISTUNRi~g 'q,':' • 'o':' 115 .15' (M) -----------------------------------~-.....l.---lll!ll!ll!l!!!!~~~~~~~~=====jl-----------------------------------33 LV0 q,'? ~-b6 V) ~ f" ""'" 00 0 • 0 °' o-.:f" z-FOUl\,D I /2"" IRON PIP[ NO 'D . '!> TRE( HOUSE 'b'!> EX-8.8 DE-8.2' ' ' J.O:l~:31\l -c,1,0 (...v : ~ _\w\,()IV : ~ Q, 1 be ~ 4<> )( • 'o· • 'b~ <I,· • <o· --~ eroSiv,._) "c,, .. ,vJ, ~J ;-":'-J, ~ {uµ+-t~l ~ ·°'-:,, __,.,.,.., ___ ~-------.1.~:'/ ~ ,o,· D 'b· r.:::::==============:::;i <l'6' PROPOSED , POOL ELEV.-9 26 D TWO STORY GARAGE FFE=9.66 •·.f . ~ ' QI· ORIV[~JAY -,· . , S89°26'10"W 115.10' (M) ., ;;.i .. ORIV[~rA Y, • . ,J COUNTRY CLUB LANE TB•A #601 M,\G NAIL W/DISK "TRAV PNT" ELEV • 7 42 (NAV0-88] 60' RIGHT OF WAY ., .. JFOUND ; /2"' IRON PIPE NO ID 0 1" = 20' GR.t;.PHIC SCALE 10· 20' GENERAL NOTES: SPECIFIC PURPOSE SURVEY SURVEY OF: LOT 3, BLOCK 5, SUBDIVISION SELVA MARINA UNIT 2, ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 27, PAGE 6-6A OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA FOR: HOWE GROVER LEGEND DE DESIGN ELEV.I\ TION NAVO NORTH AMERICAN ELEV. ELEVATION VERTICAL DA TIJ'-.1 $ BENCHtv'ARI< LB LICENSED BUS NESS x#tl-tl GRQI.J°\JD ELEVATION ID IDENWKATION LVO c.lVE OAI< 40' 1. THIS IS NOT A BOUNDARY SURVEY. 2. BY GRAPHIC PLOTTING ONLY, THIS PROPERTY LIES WITHIN ZONE "X", AS SHOWN ON THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 120075 0409 J, (MAP NO. 12031C0409J), WHICH BEARS AN EFFECTIVE DATE OF NOVEMBER 2, 2018, AND IS NOT IN A SPECIAL FLOOD HAZARD AREA. NO FIELD SURVEYING WAS PERFORMED TO DETERMINE THIS ZONE. ZONE "X" DENOTES AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. 3. IMPROVEMENTS AND UTILITIES WERE NOT LOCATED AS PART OF THIS SURVEY, EXCEPT AS SHOWN HEREON. 4. MEASUREMENT METHODS USED FOR THIS SURVEY MEET STANDARDS OF PRACTICE FOR LAND SURVEYING AS SET FORTH IN FLORIDA ADMINISTRATIVE CODE CHAPTER 5 J-17.050-.052 REQUIREMENTS. 5. NO BEARINGS SHOWN HEREON. PLAT OF RECORD DOES NOT CONTAIN ANY ANGULAR INFORMATION. 6. NOTE THAT PLAT DIMENSIONS ARE ONLY EXPRESSED TO THE NEAREST FOOT AND TO THE NEAREST MINUTE OF ANGLE. 7. ELEVATIONS SHOWN HEREON ARE REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD-88), AND ARE BASED ON THE JACKSONVILLE TRANSPORTATION AUTHORITY ROADWAY PLANS, FINANCIAL PROJECT ID 434343-1-58-02, BOX CUT IN SOUTHEAST CORNER OF CONCRETE BOX WEST OF INTERSECTION OF SEMINOLE ROAD AND 9TH STREET, ELEVATION OF 7.18 (NAVD-88). 8. ALL DATA SHOWN HEREON ARE FIELD MEASURED UNLESS OTHERWISE NOTED. 9. THE PURPOSE OF THIS SURVEY IS TO SHOW THE TOPOGRAPHICAL FEATURE IN THE REAR OF THE LOT PER CLIENT REQUEST . JOB No. 20-145 FILE No. A -250 PARTY CHIEF.· J. PRA T£R F.8. 20 I 3, PG38 DR A WN BY.· T. HODGE CHECl<EO BY: J. THOMAS REVISION· DATE: BY: SURVEY DA TE 09-23-2020 __________ ,___ ____ ,___ __ _ CAD FIL[· P:\20\20-145 COAB 325 COUNTRY CLUB LAN[ FOR IS"A\JD FOOLS\DWG\20-145-325 COUNTRY CLUB LANE-SPECIFIC PURPOSE.DWG GHIOTTO (1 RSSOCIRTES GJ-IIOTTO & ASSOCIATES, INC. NA T!ONALL Y CERTIFIED SURVEYORS & MAPPERS CERT/FICA TE OF AUTHORIZATION No. LB 6508 2426 PHILIPS HJGHW/l Y JACKSONVILLE, FLORIDA 32207 (904) 886-0071 (904) 886-7174 FAX www. CHIO TTO. com JOHN S. THOMAS P.S.M. No. 6223 NOT I/AUD WITHOUT THE SICNA TUR£ AND TH[ ORIG"/NAL RAISCO SEA!. OF A FLORIDA L!Cl:NSED SURVEYOR AND MAPPl:R Simplified Total Dynamic Head {TOH} Calculation Worksheet CALCULATIONS MUST BE PER ANSI /APSP /ICC 7-13 & FBC-R R4501 .6 The Contractor is responsible the accuracy of the Worksheet Determine Maximum System Flow Rate Minimum Flow Rate Required: 35gpm per skimmer (required: 1 skimmer per 800 sq ft of surf. area) 1. Calculate Pool Volume 4 50 X '-I, 5 X 7.48 (gal./cubic foot)= J 5 5 D e) (Su rfa c e Area) (Avg Depth) / _ (Volu me in Ga llons) 2. Determine preferred Turnover Time in Hours: __ \.D..c,.__X 60 (min/ hour)= 3~ (Ho u rs) (Tu move~ min) 3. Determine Max Flow Rate I 5 -s;o D / 3 (.p..0 + 0 = ½ tj Q Pm i _ (Vo lume in Ga llons) (Tu rnove r In Min) (Pool Flow Rate) (System Flow Rate) 4. Spa Jets: _______ LO ____ X /D GPM per jet= /o O flow rate (No of Je ts) OetFlow) (Tot.II Jet Flow Rate) (For Single Pump pool/spa combo , use the higher of No. 3 or No. 4 in the following calculations for the pool & Spa) Determine Pipe Sizes: -2 '' Branc h Piping to be ---=:.:>~-inch to keep veloci ty @ 6 f ps m ax. a t / 00 g pm Maximum System Flow Rate ,....., , '""0 Suctio n Piping to be _a-,.........__ inch to keep vel ocity@ 8 fps max. at~ gpm Maxi mum Sy stem Flow Rate Return Pipin g to be d 1 1 inch to keep v eloci ty @ 10 fps max. at / OD gpm Max imum System Flow Rate Determine Simplified TDH: 1 1. Di stance fro m poo l, to pump in F t: ~0 2 . Friction loss (i n s uction pipe) in 3' 1 inch pipe per I t .@ g pm =) 00 (from pipe fl ow/friction loss chart) ,.....,, ,~· 3. Fri c tion loss (in return pi pe ) in --"°'"--'--inch pi pe per I t. @ gpm = .liJL(from pipe flow/fri c ti on loss cha rt) 4. ~o x ,al.\ = o .'6 (Length of Suctio n Pipe) (Ft of head/I ft of Pipe) (TOH Suction Pipe) ~o x ___ • .._.., o ___ =_a.-""'---5. (Length of Suction Pipe) (R of head/I ft of Pipe) (TOH Suction Pi pe) Flow and Friction Los s Per Foot (S chedule 40 pvc Pi pe) TDH in Piping cl · g Filter loss in TDH (from filter data sheet). _ _,_/..,.S""--_ V elOdtV -~ Ptr Socond Pf?<SU• 6FPS B fPS l0 f PS 15" 37 apm o.os· SOJllm .1•· 621Pm 2· ·--0.06' 1 2tpm .10· 103•- 2.5• 88 1pm 0.05' 117 apm .08' lASJIIITI 3 • 1352nm o.o,i• l U 20m .or mapm Selected Pump and Main Drain Cover: .21' .16' .13' .10' Heater loss in TOH (fro m heater data sheet)._.._} ...,.5 ___ _ Total all other loss _ _,Q....,_~- Total Dynamic Head (TDH) 3ol · '6 Pump selection LHe./ Ii .f!o VS F-3050 u sing pump curve fo r TDH & System Flow Rate (Pump model and size in HP) Main Dr ain Cover (J'I'\ P /vO VA (System Fl ow Ra te mus t n ot exceed approved cover flow rates) (Pump model and size in HP) Notes: Minimum system flow based on minimum flow per skimmer of 35 gpm . Determine the Number and Type ofReguired In-floor Suction Outlets: (Check all that a pply) ', ~0 -3' -0 7 ¾ sucti on outlets@ /DO gpm max. flow (see note 2) D 0 0 0 _____ suction outlets @ _____ gpm max. flow (see note 3) □--------_____ channel drain @ gpm w/ ___ ports (see note 4) TOH Calculation Options (For each Pump) Check one ~ Simplified Total Dynamic Head (STDH) Complete STDH Worksheet -Fi ll in all blanks □ Total Dynamic Head (TOH) □ Complete Program or other calcs. Fill in required blanks on worksheet & attach calculations Maximum Flow Capacity of the new or replacement pump Notes: 1. If a variable speed pump is used, use the max pump low in calculations 2. For side wall drains, use appropriate side wall drain flow as published by manufacturer 3. Insert manufacturer's name and approved maximum flow 4. See installation instructions for number of ports to be used 5. In-Floor suction outlet cover/grate must conform to most recent edition of ASME/ ANSI A112.19.8 and be embossed with that edition approval 6 . Pump, Filter and Heater make and model cannot change, and equipment location cannot be move closer the pool without submitting a revised plan and TDH calculation worksheet for aooroval Pipe Size 1.5" 2" 2.5" 3• 4• 6" Velocity -Feet Per Second 6 FPS 8 FPS 37gpm 0.08' 50gpm .14' 62gpm 0.06' 82 gpm .10" 88gpm o.os· 117 gpm .08' 13611pm 0.04' 181 i;(pm .07' 234gpm 0.03' 313 gpm .OS' 534gpm 0.02' 712 gpm .03' 7 Print Name LP~ \ vl s J Y ~ 9 Telephone Number 10 FPS 62Rpm .21' 103 gpm .16' 148 gpm .13' 227 RPm .10' 392gpm .07' ANSI/ APSP /ICC Worksheet Swimming Pool Energy Efficiency Compliance Information Note: These Requirements Apply ONLY to the Filtration Pump Maximum Filtration Flow Rate Calcutlations Pool Water Voume 1656(:>+ 360 = --1i,_ gpm = filtration flow rate Is there an Auxiliary load on the filtration pump? Yes_ No__QS_ If so, what is the a uxiliary flow rate gpm Maximum Flow Rate L--\:\ gpm (maximum auxiliary pool loads or the filtration flow rate, whichever is greater. The poolfiltratio11flow rate shall not be greater than the rate needed to turn over the pool water volume in 6 hours or 36 gpm whichever is greater. Th is means that for pools of less than 13000 gallons, the pump shall be sized to have a flow rate of 36 gpm or less. It Suction Pipe size @ 6 fps 3 inch Return P ipe size @ 8 FPS ;),'' inch Filter Factors: (Cartridge .375) or (D.E 2) or (Sand 15) )00 . ~l S ~¼0 (flow rate) !lter fa~tor)~um filter size) Filter Make/Size ~,Jtt>, I t nm Backwash valve? Yes __ No ()(.._ (if yes, must be 2 inch min) Pump Selection from APSP database on Curv~ gallons) or C (greater than 17000 gallons) (circle one) Mode1:Lt--Jkl) ;f\ 0 VS f 3D SD Aow Rate (low speed) / 0 gpm @ / 0110 rpm Aow Rate (high speed) / OD gpm@ :t(()rpm ~ if no auxiliary load on filtration pump Pump Controls / Standard time clock / 2 speed time clock_/_ nor other __ _ Heater Model _______________ _ Notes: suction piping in front of pump inlet must be 4 pipe diameters in length. Must have 18" of straight pipe after the filter for solar. Swimming Pool Specifications for: Owner: ___________________ _ Address ___________________ _ City, State,Zip ________________ _ p s 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 3 1 32 33 34 35 0 0 2.3 4 .6 6 .9 9 .2 11 .5 13.9 16.2 18.5 20.8 23.1 25.4 27.7 30 32.3 34.6 37 39.3 41 .6 43.9 46.2 48.5 50.8 53.1 55.4 57.8 60.1 62.4 64.7 67 69.3 71 .6 73.9 76.2 78.5 80.9 Total Head In Feet Conversion Chart Inches Me rcury (Vacuum Gauge) 2 4 6 8 10 12 14 16 2 .3 4 .5 6.8 9 11 .3 13.6 15.8 18.1 4 .6 5 .8 9.1 11 .4 13.6 15.9 18.1 20.4 6.9 6.1 11 .4 13.7 15.9 18.2 20.4 22.7 9.2 11 .5 13.7 16 18.2 20.5 22.8 25 11.5 13.8 16 18.3 20.5 22.8 25.1 27.3 13.8 16.1 18.3 20 .6 22.8 25.1 27.4 29.6 16.1 18.4 20.6 22.9 25.2 27.4 29.7 31 .9 18.4 20.7 23 25.2 27.5 29.7 32 34.3 20.7 23 25.3 27.5 29.8 32 34.4 36.6 23.1 25.3 27.6 29.8 32.1 34.3 36.6 38.9 25.4 27.6 29.9 32.1 34.4 36.7 38.9 41.2 27.7 29.9 32.2 34.5 36.7 39 41 .2 43.5 30 32.2 34.5 36.8 39 41 .3 43.5 45.8 32.3 34.5 36.8 39.1 41 .3 43.6 45.9 48.1 34.6 36.9 39.1 41 .4 43.6 45.9 48.2 50.4 36.9 39.2 41 .4 43.7 4 5.9 48.2 50.5 52.7 39.2 41 .5 43.7 46 48.3 50.5 52.8 55 41 .5 43.8 46.1 48.3 50.6 52.8 55.1 57.4 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7 46.2 4 8.4 50.7 52.9 55.2 57.4 59.7 62 48.5 50.7 53 55.2 57.5 59.8 62 64.3 50.8 53 55 .3 57.6 59.8 62.1 64.3 66.6 53.1 5 5 .3 57.6 59.9 62.1 64.4 66.6 68.9 55.4 57.7 59.9 62.2 64.4 66.7 69 71 .2 57.7 60 62.5 64.5 66.7 69 71.3 73.5 60 62.3 64.5 66.8 69.1 71 .3 73.6 75.8 62.3 64.6 66 .8 69.1 71 .4 73.6 75 .9 78.1 64.6 66.9 69.2 71 .4 73.7 75.9 78.2 90.5 66.9 69.2 71 .5 73.7 76 78.2 80.5 82.8 69.3 71 .5 73.8 76 78.3 80.5 82.8 85.1 71 .6 73.8 76.1 78.3 80.6 82.9 85.1 87.4 73.9 76.1 78.4 80.7 82.9 85.2 87.4 89.7 76.2 78.4 80.7 83.1 85.2 87.5 89.7 92 78.5 80.7 83 85.3 87.5 89.8 92 94.3 80.8 83.1 85.3 87.6 89.8 92.1 94.4 96.6 83.1 85.4 87.6 89.9 92.2 94.4 96.7 98.9 18 20.3 22.7 25 27.3 29.6 31 .9 34.2 36.5 38.8 41 .1 43.4 45.8 48.1 50.4 52.7 55 57.3 59.6 61 .9 64.2 66.5 58.9 71 .2 73.5 75.8 78 80.4 82.7 85 87.3 89.6 92 94.3 96.6 98.9 101 .2 ,. NOTE: F IELD TOH MU ST BE EQUAL T O OR HI GHER THAN T HE CALCULATED T OH . ..., GAGES TO B E INSTALLED AT TH E T IME OF F INAL INSPECTION FOR V ERI FICATI ON. ool beam is 8"-9'' levation is even with xisting patio decking will e 23/8" paver declking nd will cover existing 7ft 1ised spa 12" 6 therapy ~ts with 10" beam 2hp lower and 399K BTU ropane gas heater 120K Umbrella holder in sunshe lf TU heat pump IC40 wi~ asy touch LED pool and Ja 120v lights. VErify poc I '-Q 10' quip me nt I ocati on bef o rE_.__L----------=----=----=---=--=-,--, 11' =tting ~ ,~ .. ~ I I-¾ ~ µ. 3.5ft ~ ~ fl_l 1n ~ lU' 11 i 7 ' 1 n• 11 11 6therapy jets and horse s oP hPnrh nlp;ic:;p mark Mi r and water lines 16' _J u :ess this side Existing hom e 38' _jL, I 32 6 .5ft Ugh' ~ 1 Cl' l I 'rl 0 I! co 4' iD 5 ' u RD Gray Island Poo ls LLC 904 · 334-5421 rd@is landpoofs_ org 12' L M N Barriers per FBC2017 water alarms and fencing Garage RD GRAY 334-5421 Owner: Howe Grover uMI 11 ,\,t H, 11 \! o,: State: __ _ Address: 325 Country Club Ln Zip: ___ _ City: Atlantic Beach Phone: ___________ _ Phone: ___________ _ POOL SPECS SIZE: 15x32 SQFT: ..:::4Sc::..O s:::.:ft ______ _ DEPTI-i : 3.5-6 PERIMETER: =90'-"lft~----- ESi TOTAL GALLONS:_____ SKIMMERS: -=-1 _____ _ RETURNS: 3 INTERIOR MATERIAL: ____ _ SPECIAL: ________ TILE'. _______ _ NOTES: _________________ _ SPA SPECS SIZE: 6x9 flu sh SQFT: _______ _ DEPTI-i : 3.5ft PERIMETER: ______ _ EST TOT AL GALLONS:_____ SPILLWAY: ______ _ RAISED HEIGHT: ______ SKIMMERS: ______ _ RETURN S: ________ TILE: _______ _ INTERIOR MATERIAL; ______________ _ SPEC IAL: _________________ _ NOTES: _________________ _ PLUMBING RE71JRNS: ;::.,3 ______ _ SKIMMERS: .._1 _____ _ POOL MAIN DRAINS: :..2 ____ _ SPA MAIN DRAINS : ____ _ CLEANING SYSTEM: =su=cti=o"'------HEADS: _______ _ VAC LINES: ______ _ ROBOTVAC: ______ _ WATER FEATURES: _____ _ SPA SPILLWAY: _____ _ LIGHTS IN POO L: _____ _ LIGHTS IN SPA, _____ _ TOTAL PIPE: ________________ _ SPECIAL: _________________ _ NOTES: _________________ _ DECK DECK TYPE: !:!!.Bn,.:a,'ck:..1<p,,.,_av=ers::.._ ___ _ ELEVATION: ______ _ TOTAL DECK SQF'T: :::,:50:.:::..0 s"'-'ft'------PERlMETER: ______ _ RAISED BEAM: ______ _ LIP STYLE: ______ _ MATERIAL l: ______ _ MATERIAL 2: ______ _ SPECIAL: _________________ _ NOTES: _________________ _ EQUIPMENT POOl-PUMP: IntelliOo VS3050 2 ND PUMP: ______ _ FILTRATION: =ca=rtr=id=ge_____ FILTE R SIZE: =RP ___ l ___ So ____ _ HEATER : INUNc: _______ _ TIMER: Easy Touch '1 Fun ction GAS: _______ _ SPECIAL: .!l:IC;..:!40;t__ _______________ _