Loading...
250 Beach Ave ROOF24-0005 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: WEED WENDY A 250 BEACH AVE ATLANTIC BEACH FL 32233-5214 COMPANY:ADDRESS:CITY:STATE:ZIP: Covenant Roofing & Construction 4590 CR 218 Middleburg FL 32068 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170195 0000 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 250 BEACH AVE ROOF NON SHINGLE METAL ROOF - GARAGE $24680.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING NOTICE OF COMMENCEMENT INFORMATIONAL Notes: No inspections may be scheduled until a copy a recorded Notice of Commencement has been submitted to the Building Department 2 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In- Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 1/26/2024 PERMIT NUMBER ROOF24-0005 ISSUED: 1/26/2024 EXPIRES: 7/24/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $175.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $87.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.94 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.63 TOTAL: $269.07 2 of 2Issued Date: 1/26/2024 PERMIT NUMBER ROOF24-0005 ISSUED: 1/26/2024 EXPIRES: 7/24/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION METAL ROOF - GARAGE 250 BEACH AVE Covenant Roofing & Construction ROOF24-0005 ROOF24-0005 1/2/24, 11:16 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtcpgfIynXQVdmda12NzCFr1sq15jH0A4e5x3D8Lu1dhA%3d%3d 1/3 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL33818-R4 Application Type Revision Code Version 2023 Application Status Pending FBC Approval Comments Archived Product Manufacturer Gulf Coast Supply & Manufacturing, LLC. Address/Phone/Email 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352) 498-0778 Ext 0565 jared.pearce@gulfcoastsupply.com Authorized Signature Jared Pearce jared.pearce@gulfcoastsupply.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report David Eng Florida License PE-81377 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2099 Validated By James R Wally, PE Validation Checklist - Hardcopy Received Certificate of Independence FL33818_R4_COI_26ga_5V_plywood_HVHZ.pdf Referenced Standard and Year (of Standard)Standard Year TAS 100 2023 TAS 125 2003 UL 1897 2015 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code ROOF24-0005 1/2/24, 11:16 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtcpgfIynXQVdmda12NzCFr1sq15jH0A4e5x3D8Lu1dhA%3d%3d 2/3 Product Approval Method Method 1 Option D Date Submitted 12/11/2023 Date Validated 12/22/2023 Date Pending FBC Approval 01/01/2024 Summary of Products FL #Model, Number or Name Description 33818.1 01: 26ga 5V on plywood 26ga (min) 5V Crimp on 15/32" (min) plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5 Other: See evaluation report. Installation Instructions FL33818_R4_II_26ga_5V_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL33818_R4_AE_26ga_5V_plywood_HVHZ.pdf Created by Independent Third Party: Yes 33818.2 02: 032 5V on plywood Nominally 0.032" or thicker 5V Crimp on 15/32" (min) plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: See evaluation report. Installation Instructions FL33818_R4_II_032_5V_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL33818_R4_AE_032_5V_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes 33818.3 03: 26ga 5V on 1x4's on plywood 26ga (min) 5V Crimp on 1x4's on 15/32" (min) plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-75 Other: See evaluation report. Installation Instructions FL33818_R4_II_26ga_5V_1x4_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL33818_R4_AE_26ga_5V_1x4_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes 33818.4 04: 26ga GulRib on plywood 26ga (min) GulfRib on 15/32" (min) plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.25 Other: See evaluation report. Installation Instructions FL33818_R4_II_26ga_GulfRib_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL33818_R4_AE_26ga_GulfRib_plywood_HVHZ.pdf Created by Independent Third Party: Yes 33818.5 05: 29ga GulfRib on plywood 29ga (min) GulfRib on 15/32" (min) plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: See evaluation report. Installation Instructions FL33818_R4_II_29ga_GulfRib_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL33818_R4_AE_29ga_GulfRib_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes 33818.6 06: 26ga GulfRib on 1x4's on plywood 26ga (min) GulfRib on 1x4's on 15/32" (min) plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-164.25 Other: See evaluation report. Installation Instructions FL33818_R4_II_26ga_GulfRib_1x4s_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL33818_R4_AE_26ga_GulfRib_1x4s_plywood_HVHZ.pdf Created by Independent Third Party: Yes 33818.7 07: 29ga GulfRib on 1x4's on plywood 29ga (min) GulfRib on 1x4's on 15/32" (min) plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Installation Instructions FL33818_R4_II_29ga_GulfRib_1x4s_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 METAL ROOFING PRODUCTSMETAL ROOFING PRODUCTSMETAL ROOFING PRODUCTSMETAL ROOFING PRODUCTS 1.888.393.03351.888.393.03351.888.393.03351.888.393.0335 wwwwwwwwwwww....GGGGuuuullllffffCCCCooooaaaassssttttSSSSuuuuppppppppllllyyyy....ccccoooommmm FL33818.04-R4 HVHZ 26ga (min) GulfRibGulfRibGulfRibGulfRibTMTMTMTM over 15/32” (min) plywood Gulf Coast Supply & ManufacturingGulf Coast Supply & ManufacturingGulf Coast Supply & ManufacturingGulf Coast Supply & Manufacturing 14229 SW 2nd Pl G30, Newberry FL 32669 Product DescriptionProduct DescriptionProduct DescriptionProduct Description:::: Rib/Ag exposed fastener panel with nominal 36” max coverage and nominal rib height of ¾”. Product MaterialProduct MaterialProduct MaterialProduct Material:::: 26ga (min) steel Corrosion resistant per FBC 1507.4.3 where required FastenerFastenerFastenerFastener:::: #9 x 1.5-inch fastener with sealing washer Compliant with FBC 1506.6 where required. Substrate/DeckSubstrate/DeckSubstrate/DeckSubstrate/Deck:::: 15/32” (min) plywood or ¾” (min) SYP wood plank. Maximum Allowable Loads & Installation Maximum Allowable Loads & Installation Maximum Allowable Loads & Installation Maximum Allowable Loads & Installation Requirements:Requirements:Requirements:Requirements: MethodMethodMethodMethod Fastener PatternFastener PatternFastener PatternFastener Pattern Fastener SpacingFastener SpacingFastener SpacingFastener Spacing Allowable PressureAllowable PressureAllowable PressureAllowable Pressure Method A #9 fastener in 9”-9” pattern (1 per rib) 24” o.c ----71.771.771.771.75555 PSFPSFPSFPSF Method B #9 fastener in 6.5”-2.5” pattern (2 per rib) 12” o.c. ----151515159.259.259.259.25 PSFPSFPSFPSF A factor of safety of 2 has been applied. Evaluated by: Evaluated by: Evaluated by: Evaluated by: David Eng, PE Timberlake Cove, LLC 1317 Edgewater Dr, Ste 2339 Orlando FL FL PE 81377 | FL CA 33344 www.TimberLakeCove.com This item has been digitally signed and sealed by D.E. Eng, PE, on the date indicated. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Digitally signed by David E Eng Date: 2023.12.11 10:26:17-05'00' Page Page Page Page 2222 www.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.com GulfRibGulfRibGulfRibGulfRibTMTMTMTM FL33818.04-R4 HVHZ Underlayment:Underlayment:Underlayment:Underlayment: Comply with local building code or FBC 1507.1.1/1518.2 where required. Slope:Slope:Slope:Slope: Comply with local building code or FBC 1507.4.2/FBC 1515.2 where required. ReReReRe----RoofingRoofingRoofingRoofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511/1521, provided the existing roof meets the conditions required by the applicable code. Fire Barrier:Fire Barrier:Fire Barrier:Fire Barrier: Comply with FBC 1516.1 and 1516.2 where required. Technical Documentation: Technical Documentation: Technical Documentation: Technical Documentation: This product has been tested to the TAS 125 / UL 580 standard by Force Engineering (TST- 5328), report 117-0062T-07 A-C and to TAS 100 by Farabaugh Engineering and Testing (TST-1654) under report T126-07A. Compliance Statement: Compliance Statement: Compliance Statement: Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2023, 1504.3.2 (nonnonnonnon----HVHZHVHZHVHZHVHZ) and 1518.9.1/1523.6.5.2.4 (HVHZHVHZHVHZHVHZ), as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 – Test for Uplift Resistance of Roof Assemblies • UL 1897 – Uplift test for roof covering systems • TAS 125 – Standard Requirements for Metal Roofing Systems • TAS 100 - Wind and Wind-Driven Rain Design Process:Design Process:Design Process:Design Process: Compare the maximum allowable loads on page 1 to the ASD uplift pressures for the project to determine sufficiency and installation requirements. Alternatively, as an option, the load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-22. Use of these tables assumes that the structure is: Enclosed and conforms to wind-borne debris provisions and is a regular shaped building and is not subject to across-wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. Certification of Certification of Certification of Certification of Independence:Independence:Independence:Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations:Exclusions and Limitations:Exclusions and Limitations:Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Installation shall be subject to the local building code and authority having jurisdiction; this report shall not be construed to supersede local codes in force. Page Page Page Page 3333 www.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.com GulfRibGulfRibGulfRibGulfRibTMTMTMTM FL33818.04-R4 HVHZ Use of Load Tables:Use of Load Tables:Use of Load Tables:Use of Load Tables: These load tables are provided as a courtesy to provide one possible prescriptive option for a generic, typical structure without calculating the design pressures. For structures outside the parameters of these load tables (e.g. height above 30 feet), calculate the required allowable design pressure and compare to the maximum allowable loads shown on page 2. These load tables shall not be construed to in any way limit the installation of this product to the cases shown. Instructions:Instructions:Instructions:Instructions: Select the appropriate load table that applies to the structure in question. Determine the design wind speed for the project location. Use the attachment method indicated for that windspeed within each roof zone. Use this load table for structures which meet the following criteria:Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 12:12 Have either a flat roof, or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1:A A A A A A A A A B B Zone 1:A A A A A B B B B B B Zone 2:A A A A A A A B B B B Zone 2:A A A B B B B B B B NR Zone 3:A A A A A B B B B B B Zone 3:A A B B B B B NR NR NR NR Use this load table for structures which meet the following criteria:Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7°, hip roof with max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1:A A A A A A A A A A B Zone 1:A A A A A A B B B B B Zone 2:A A A A A A A A B B B Zone 2:A A A A B B B B B B NR Zone 3:A A A A A A B B B B B Zone 3:A A B B B B B B NR NR NR FL33818.04: 26ga GulfRib on 15/32" plywood FL33818.04: 26ga GulfRib on 15/32" plywood FL33818.04: 26ga GulfRib on 15/32" plywood FL33818.04: 26ga GulfRib on 15/32" plywood BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL17401-R7 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Mid-States Asphalt & Cant Strip, Inc. Address/Phone/Email 1637 51st Ave Tuscaloosa, AL 35401 (205) 394-3078 moises@msaroof.com Authorized Signature Moises Rached moises@msaroof.com Technical Representative Moises Rached Address/Phone/Email 1637 51st Ave Tuscaloosa, AL 35401 (205) 469-2101 moises@msaroof.com Quality Assurance Representative Moises Rached Address/Phone/Email 1637 51st Ave Tuscaloosa, AL 35401 (205) 469-2101 moises@msaroof.com Midstates High Temp Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL17401_R7_COI_MSA17001.4 2020 FBC Eval QUIK-Stick final.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D 1970 2015 TAS 103 2020 TAS 110 2000 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/14/2021 Date Validated 12/14/2021 Date Pending FBC Approval 12/17/2021 Date Approved 02/08/2022 Summary of Products FL #Model, Number or Name Description 17401.1 QUIK-Stick Ice & Water Granular, QUIK- Stick Ice & Water Sand, QUIK-Stick HT Smooth, QUIK-Stick HT Pro, QUIK-Stick FS Self-Adhered Underlayments Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-52.5 Other: Refer to Evaluation Report for Limitations of Use. Wind uplift applicable to QUIK-Stick HT only. Installation Instructions FL17401_R7_II_MSA17001.4 2020 FBC Eval QUIK-Stick final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL17401_R7_AE_MSA17001.4 2020 FBC Eval QUIK-Stick final.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: CREEK Technical Services, LLC MSA17001.4 FL17401-R7 Page 1 of 4 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Registry No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: MID-STATES ASPHALT AND CANT STRIP, INC. Issued December 13, 2021 1637 51st Street Tuscaloosa, AL 35401 (800) 489-2391 www.msaroof.com Manufacturing Location: Tuscaloosa, AL Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) BWR-514-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) BWR-522-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) BWR-534-02-01 ASTM D 1970 ASTM D 4798 2015a 2011(2016) PRI Construction Materials Technologies (TST5878) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) WRMI-011-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) MSA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-047-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-048-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-054-02-01.1 TAS 103 TAS 110 2020 2000 PRI Construction Materials Technologies (TST6049) MSA-056-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-057-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-060-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-060-02-02 TAS 110 2000 PRI Construction Materials Technologies (TST6049) MSA-062-02-01 ASTM D 1623 2017 PRI Construction Materials Technologies (TST6049) 1085T0002 TAS 110 2000 PRI Construction Materials Technologies (TST6049) 1085T0007 ASTM D 1623 2017 PRI Construction Materials Technologies (TST6049) 1085T0011 ASTM D 1623 TAS 103 2017 2020 PRI Construction Materials Technologies (TST6049) 1085T0015 ASTM D 1623 TAS 103 2017 2020 PRI Construction Materials Technologies (TST6049) 1085T0019 ASTM D 1970 TAS 110 2015a 2000 A CREEK Technical Services, LLC MSA17001.4 FL17401-R7 Page 2 of 4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MID-STATES ASPHALT AND CANT STRIP, INC Self-Adhering Underlayments PRODUCT DESCRIPTION AND LIMITS OF USE QUIK-Stick Ice & Water Granular QUIK-Stick Ice & Water Granular is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 50 mils. QUIK-Stick Ice & Water Granular is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick Ice & Water Sand QUIK-Stick Ice & Water Sand is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and surfaced with sand. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 50 mils. QUIK-Stick Ice & Water Sand is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick HT Smooth QUIK-Stick HT Smooth is an ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and woven poly-fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft or 3-ft 3-in x 61-ft and has a nominal thickness of 60 mils. QUIK-Stick HT Smooth (Woven Facer) is to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1. QUIK-Stick HT is permitted to be used with mechanically attached or adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160, DAP Touch ’n Seal® Storm Bond Roof Tile Adhesive or DuPont™ TILE BOND™ Roof Tile Adhesive. Exposure on the roof deck shall be limited to a maximum 180 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. QUIK-Stick HT Pro QUIK-Stick HT Pro is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and poly-fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 60 mils. QUIK-Stick HT Pro is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 120 days. QUIK-Stick FS QUIK-Stick FS is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and textured film surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 45 mils. QUIK-Stick FS is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. A CREEK Technical Services, LLC MSA17001.4 FL17401-R7 Page 3 of 4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MID-STATES ASPHALT AND CANT STRIP, INC Self-Adhering Underlayments PRODUCT APPLICATION Min. Roof Slope: 2:12 or in accordance in with the FBC Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3” side laps and minimum 6” end laps staggered min. 6-ft.from preceding course. It is permissible to back nail the underlayment 12-inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Min. Application Temperature: 40°F; Contact the manufacturer when installing at temperatures below the minimum application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 – QUIK-Stick HT Smooth only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24” o.c. Underlayment: QUIK-Stick HT Smooth shall be fully adhered to the optionally primed plywood deck. Maximum Design Pressure: -52.5 psf A CREEK Technical Services, LLC MSA17001.4 FL17401-R7 Page 4 of 4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MID-STATES ASPHALT AND CANT STRIP, INC Self-Adhering Underlayments GENERAL LIMITATIONS 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT This item has been digitally signed and sealed by Zachary R. Priest, PE, on 12/13/2021. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 2021.12.13 15:08:50 -05'00'