1652 COQUINA PL RES24-0036 -v-ANr BUILDING PERMIT APPLICATION v'r �',.,\,, •� FOR INTERNAL OFFICE USE ONLY ''' City of Atlantic Beach Building Department PERMIT# NE Z4 - 00?J(..p 800 Seminole Road, Atlantic Beach, FL 32233 **ALL information required to process "�u,ci� V Phone: (904) 247-5826 Email: Building-Dept@ coab.us Job Address 1652 Coquina Place RE# 169579-1020 Legal Description Ocean Grove unit No 01 pt of lot 4 Blk 7 Valuation of Work(Replacement Cost) $140,000.00 Heated/Cooled SF 1366 Non-Heated/Cooled SF •Class of Work: ❑ New ❑Addition ❑X Alteration ['Repair ❑Move ['Demo ❑Pool ['Window/Door •Use of existing/proposed structure(s): [Commercial ['Residential • If existing structure, is a fire sprinkler system installed?:[Yes❑X No •Will tree(s) be removed in association with proposed project? ❑Yes (Must submit separate Tree Removal Permit) ❑ No Describe in detail the type of work to be performed: Enlarge kitchen,remove closet wall,new kitchen cabinets, new kichen plumbing, new light fixtures, 1 new vanity Florida Product Approval# Drxn12.\FLNDtivaFiz, lyr -,I Flit (For multiple products use Product Approval Information Sheet) Property Owner Information Name Helen Bryan f1347 •9 Phone 904-534-2585 Address 1652 Coquina Place City Atlantic Beach State FI Zip 32233 Email ? Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company Cornelius Construction Phone 904-249-9706 Address 218 Bay Street City Neptune Beach State Fl Zip 32233 Qualifying Agent Margaret Cornelius State Certification/Registration# CBC048967 Email peggy@corneliusconstruction.com Job Site Contact Number 203-610-0231 Worker's Compensation Insurer OR Exempt I Expiration Date Architect's Name Email Phone Engineer's Name Hulsberg Engineering Email DMurray@hulsbergengineering.c, Phone 904-886-2401 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this city/county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. **WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE SITE OF THE IMPROVEMENT BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COM ENCEMENT. zdeaj (Signa a of Owner or Agent) ( (Si:• -ture of Contractor) r Signed and sworn to(or affirmed) before me this 0 day of Si ed an sworn to(o affi ed) before me his day of FtG�Y ,�a✓. / iik�� (r _ v-)2! 4 �YIII � , 4i , At , 40 /47,Signature of NotaryAIR Signature of Notary fa diller [ ] Personally Known OR [ I Produ -d Identification -t- t Personally Known OR [ I Produced Id:ntif ation Type s - .......---.-.- -----'-'1 Type of IderolF1L4p:p. •t� TONI GINDLESPERGER �P° ;4..,.` ;ro.• ' '�C, TONI GINDLESPERGER MY COMMISSION#HH 407122 : ' MY COMMISSION#HH 407122 �`P' EXPIRES'October 6,2027 *. EXPIRES:October 6,2027 .�,� _ J.... 0 CORNELIUS CONSTRUCTION COMPANY EST.1985 COVER PAGE OWNER NAME ftE) N BRYAN, ADDRESS [�52, 0501JItip, PIpc CONTRACTOR'S NAME CnKVELI 5 69N5TRL c..710 K.- CONTRACTOR .-CONTRACTOR EMAIL FE.GGY CO COR.NELIU$ cORSTRocr,)M .gym JOB SITE PHONE NUMBER 203 - @lb- DZ 31 1. ADDRESS OF PROJECT 1 (,5 2 Cost()1 NIA P1,4CE 2. OCCUPANCY CLASS -f;=S Ff D SO- GO 3. APPLICABLE CODES NATIONAL ELECTRICAL CODE FLORIDA BUILDING CODE 202e3rdition NATIONAL FIRE PREVENTION CODE 4. INDEX 1. coV Z. pA6E. 2. BU►LDINC., tPF6Zm1T )4PPL• 3 f\Mi �r, comr icE.ME_Wr 4 E.X15 -1 NC, .IOoP P.- r( 5. Ng.ifit POORpL,A1-1 6. HUL.S5EIn�67 ER61K=EIZ1,1( UTTER 7 sOWFY 8. S11).4.c-, AR_EA 9. APPA DAA!IT FOR R►=NOVAT41� 10. 5. PRINTED NAME 1-4 E. cH bRYP R 6. METHOD OF CONSTRUCTION 1� 7. CONTRACTOR 6R1�E SOS 6DNSTRUc-TI Ott MARGAit -- GRMEi-JC S LICENSE# (' RcpCJr-Qg6,7 ADDRESS: 2) BA1� .ST�P�Ti I IEPTUN6=- Pic► �H 14 �.ud a, iL 'a MA G Ai T CORNELIUS, DATE TEL(904)249-9706 THOUGHTFUL RENOVATIONS 1 NEW CONSTRUCTION PO BOX33071al I AT LANTI C6EA CH,F32233 WWWCONELIUSCONSTRUCTION.COML LICENSE CBC048967 _ mit q'. NEIN kOTtn� : wr,,rLpIA? P- e 1 )10k '1)( Y1 .9 c.(020- 6 pc,. Bi 'AN I& 2Z c 0' PIACF lz . .L.2.9"__ . ,, 24" ...., _.,_ _..,.._ ..34''_ . ._. 64" _.__ . ,. 24" 3/4", 1 .1„,,......:.......?.4!---/- *-1'.:"..'—k-:,---%,,,,......"-...:\ -,:_...•_k;i._-%,,,-...--._`\ ._ ,,-,,t_ ln r u l [ t _ --,_. / 101 10 --------- --a = a 3 rn� u --- — W2424 i ' 1 m I)0245C-T3(�j N . r UDE Clh3i►-I r �,�C4Tta�4 ,p� o, fa CUP6�e>r 1.- F 135 aLR.JX.( N P�� F)SO-) ivPA'r')<EL A?7 \ -- -u-; so o .4 t _ t i' o -0- 1 _ b 1. al e' N V_N p�'2�-1•sc-t)q P xi • I " 30" 24" 37 1} 1te,t • :_..- / T!^AIsSr) c15E-A4-4 All 5L - All dimensions and size designations Design drawings are provided Designed:12.06.23 must be verified on the site to fit Job conditions for the fair use by the client or Printed:12.06.23 904%2_41 ' g TO CO Client accepts these drawings as is and his agent in completing the can use them on its own risk. project as listed within this contract • Design:Bryan-Kitchen 11.27 Drawing#:1 Display settings7/16"= 1' HULSBERG ESTG ENGINEERING X,— February 2,2024 Peggy Cornelius Cornelius Construction 1556 Atlantic Blvd. Neptune Beach, Florida 32266 Re: Structural Alteration Summary—1652 Coquina Place,Atlantic Beach, FL Mrs. Cornelius, The purpose of this structural alteration summary is to provide direction to remove an interior floor load bearing wall at 1652 Coquina Place. We understand proposed alterations include removal of the first level interior floor load bearing wall, spanning north/south, that support conventional framed dimension lumber floor joist spanning east/west. Work associated has been classified as level 2 alteration, as defined by 8t Edition (2023) Florida Building Code (FBC) for Existing Structures, section 603. We have reviewed the existing conditions during a site visit on Monday January 22nd 2024. The following outlines the required alteration elements: • Interior 2x4 frame wall spanning+/- 18' from the interior separation wall of the adjoining unit is proposed to be removed. This wall supports 2x8 floor joist @ 16" on center spanning east/west the full width of the conditioned footprint. Review of the second level roof construction identified roof truss framing that span from exterior wall to exterior wall, therefore no roof loads are communicated to the altered framing below. For this reason, no wind generated uplift demand is anticipated. Mechanical connector uplift load path to strap beam to studs and anchor studs to foundation is not required and may be provided by the contractor as desired. o (4) 1 3/4" x 11 7/8" x +/- 18'-9" long 2.0e LVL shall be framed in place of the bearing wall. Fasten plies of the beam with (2) Rows '/4" x 6" long SDS or #14 wood screws @ 24" on center applied at both faces of the beam. Stagger rows of screws on each face and offset fasteners from opposite faces of the beam to avoid conflict. The new LVL can be upset so that the top of the LVL is flush with the top of existing 2x8 floor joist. With temporary shoring, by contractor, is in place the 12058 San Jose Blvd.,Suite 1001,Jacksonville,Florida 32223 Phone(904)886-2401—Florida Registry No.25846 Re: 1652 Coquina Place,Atlantic Beach, Florida February 2, 2024 Page 2 of 2 2x8 joist can be cut back to hang into the side of the built up 4-ply LVL with LUS28 hanger at each joist. o New 4-ply LVL beam shall be supported on minimum (3)2x4 No.2 SPF or SYP Built-up stud group. Fasten plies with(2)rows 10d 0.131x3"nails @ 8"on center, stagger rows. o We have reviewed anticipated loading associated with the altered beam and conclude that no foundation work is required,assuming a minimum 12"wide x 12" thick interior thickened footing was provided below the original floor load bearing wall. Please note that this review was limited to information provided by the property owner, available via public record, and onsite by way of limited visual observation. It should not be viewed as a comprehensive structural evaluation. If you have any further questions,please feel free to contact me. .S(eEK ........�9q Sincerely Derel( Digitally signed No 71457 by Derek Murray STATE OF LCi Derek B Murray, P.E. Date: 2024.02.02 %���s:�� o R10.-'0\, �;' FL PE No. 71457 M u r ra 16:29:45 -05'00' ''',.;�'ONAt-�".�`'' y Derek B Murray,State ofFlorida,Professional Engineer,License No. 71457 This item has been electronically signed and sealed by Derek B Murray,P.E.on February 2,2024 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. -9 4 ,,r.4F �' °>, ,LANDMARK ' 4.541._tfo.Nes it T I T L L±:-..-,,s. s. r :: a (904)998-9733 v,: '-'-1 ' www.landmarktitle.com ? 7 ,T> e ? ;•-,.I';'';,-..::...',,t:;:: 1 1 R, a PROPERTY ADDRESS:1652 COQUINA PL,ATLANTIC BEACH,FL 32233, OLOCR CORNLR• BLocf,lir 40.00'(Fu ) AT Lot I .u001,6 lir IV COPJ1ER For - ND 10 O N as G O REMAINDER S OFLOT 4 Q BLOCK 7 �" 16 a (NOT INCLUDED) . a • ' • ypttCN[0 N COYEA4d51'(M) : ,�z•ro. • N1D Dx c A Ii cam' r.D *8wG 49.00.'(D) NO ID 20.a ID 47337 I. . UNS BUROR7G - _ • w.0010 O.s'ON `,; I T • PAS _ - 14.N � 7.t Wow %CONC, $ Oen tO LOT 3 PORTION _ C BLOCK7 OF LOT 4" AveR $'.- o Wow •=_„ BLOCK?; •, ww, c I a c asil —.–%STY: O % DUPLEX 7.a r- RES-#1652 --_ a 4.7 coNc. 'Tt DEM I O4• 14.9 22.0 0.9._ 8. r I _ 4600• ....At 20.a!y_ 6 _ I 0.3' or . .._© ?ND rjIALTEtta',49.00'M) w Lp733, I a.Nr W O 49.29' ) • WICAP ' ifl 1893G72 O O LOT5 LOT B BLOCK 7 BLOCK 7 20 0 10 20 GRAPHIC SCALE(In Feet) 1 inch=20'11. POINTS OF INTEREST: 11111u9,NN,,, SURVEYOR'S CERTIFICATION 1.CONCRETE DRIVE OVER 3'UTILITY EASEMENT. 0V.i A.At2.WOOD FENCE OVER 3'UTILITY EASEMENT. qt,* .y,'�,� REPRODUCTIONS OF THIS SKETCH ARE NOT ' ' '' s VALID UNLESS SEALED WITH FLORIDA PSM I.(N°•P54g274 1 9. EMBOSSED SEAL.THIS SKETCH OF SURVEY * J'`- OR PLAN DEPICTED HEREON CONFORMS TO i .. l7ATE OF ;`04 THE STANDARDS OF PRACTICE SET FORTH vt- °"1°�r ` BY THE FLORIDA BOARD OF SURVEYORS lANB` AND MAPPERS IN ACCORDANCE WITH —.I.//. 11 CHAPTER 5J-17.050-17.053,PURSUANT TO CHAPTER 472,FLORIDA STATUTES,AND WAS DONE UNDER MY DIRECT SUPERVISION. DATE SIGNED:11/22/2023 RIVER CITY SURVEYING d MAPPING FIELD WORK DATE:11/22/2023 't .i - ,.3 904.675.930D&904.675.9301 REVISION DATE(S): ,ar F.904-988.9738 7220 FINANCIAL WAY I JACKSOFL 3220NVILLE,6 SURVEY NUMBER: 101013 01 `-au.Umum- , CERTIFIED TO: i HELEN BRYAN, SEE PAGE 2 OF 2 FOR LEGAL DESCRIPTION LANDMARK TITLE LLC, CASH TRANSACTION. PAGE 1 OF 2-NOT VALID WITHOUT ALL PAGES OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY , r wv,,,ipiiKa )OFir. C R j1 LANDMARK t 1,I.nf i;:, 1, K ,, g, T i T L E _:, I I ..' 5.• N•• .••, • ,.1-4114":".: - Ci 1'a Y4y'I • 1•R.4,.%. i (904)998-9733 ':1 www.landmarktltle.com Jill �I 11J ��7. 7Jrr ..'' '� Lau. �.fieeti.i. ti PROPERTY ADDRESS:1652 COQUINA PL,ATLANTIC BEACH,FL 32233. 9WCR GORNNLpP. e A 40.00'(P) ATlir of CORNER,Fr NO 10 631 SI A REMAINDER q. OFLOT4 S BLOCK 7 ` 18.0 (NOT INCLUDED) S zietEM .. ,48,511/ $ IR-nP MD O(ACTA t CONI a ,4800'(D N0 a � zo.a - In(2237 . uNe 14.8�" . 0.5'ON1.=—' I.T ' MRh. y'y 7.2' .1 - i�@@@ YYN,L_ V Owoo° 4 CONC ^Ii O- LOT 3 = PORTION C BLOCK T ---t OF LOT 4 AVCR t O ettrs ,-i (WOI UDED) - -� 7....;=---%." O 2 STY. - % DUPLEX _7.0 RES.#1652. _- Q $At C-1F-0. _ _ `•° I . its, ',Z_22.0 0."_ 14.7 ,,y IRI - . I I5, . )89'48'00 j0U 20.0 . 0.3'OFF I! - 4 FNO t3#CTA 12'RP I o © w o Z 4919'0) w Lb"337 - WJCA' “! '4 m 0513672 i O A LOT 5 LOT 8 BLOCK 7 BLOCK 7 20 0 10 20 GRAPHIC SCALE(In Feet) 1 inch=20'it. SURVEYOR'S CERTIFICATION POINTS REOF INTEREST: �""""""1. 1.CONCRETE DRIVE OVER 3'UTILITY EASEMENT. �'�••.. 2.WOOD FENCE OVER 3'UTILITY EASEMENT. �`��9, REPRODUCTIONS OF THIS SKETCH ARE NOT PI/ 4' = o • �' St.Johns County Board of County Commissioners Growth Management I Building Services Division • Q Affidavit for Renovations and Remodeling ORA The work performed on an existing building shall be classified per the Florida Building Code by electing the level of alteration. 502.1 Repair: Patching or Restoration of materials,elements,equipment,or fixtures for the purpose of maintaining such materials,elements,equipment,or fixtures. 503.1 Level 1 Alteration includes the removal and replacement or the covering of existing materials, elements,equipment,or fixtures using new materials,elements,equipment,or fixtures that serve the same purpose. 504.1 Level 2 Alteration includes the reconfiguration of space,the addition or elimination of any door or window,the reconfiguration or extension of any system,or the installation of any additional equipment. 505.1 Level 3 Alteration applies where the work area exceeds 50%of the aggregate area of the building and made within any 12 month period. 506.1 Change of Occupancy shall comply with the provision of Chapter 10,FBC-Existing Building. Please list the complete scope of work proposed for this project: -Rpril()VE et( THJG WA)I ��i t 1=N 3..1 VW:4 r .!?C)M 4- V.<1TC_}-(E1..t REPL-ACE nt-C44EJ( CA IllF'T5 d- APPl._JA11'tCS 7A04-r- I NTERIbe REDL/ Cr- Finn (L)1TH L 1) OlZ( kI( NYir R l= P LAC- MJ l u 1'ot,0 MY 15A c K 006 I(PRINT) affirm the scope of work listed above represents the entire project. I understand any work not listed above will require an approved revision. Work commenced prior to obtaining a permit can result in the issuance of a stop work order and penalty charges. Signature of Owner/Contractor/Design Professional In St.Johns County,Florida The foregoing Instrument was Acknowledge Before me on 20 Notary Seal Known Personally or Identification Name of Notary,typed or printed Signature Note:Opening Protection is required for additions and remodels with a valuation of$50,000 or more when the home is valued at 5750,000 or more,except single family structures permitted under the Florida Building Code. Revised 01.22.18