Loading...
1626 W PARK TER POOL24-0007 �,::,>;, BUILDING PERMIT APPLICATION FOR INTERNAL OFFICEUSEONLY City of Atlantic Beach Building Department PERMIT# �oc*� Zq - OC)O7 �1 800 Seminole Road,Atlantic Beach, FL 32233 **ALL information required to process '''.9J.,.?' Phone: (904) 247-5826 Email: Building-Dept@c0ab.uS Job Address 1626 Park Terrace West Atlantic Beach,Florida 32233 RE# Legal Description 34-51 09-2S-29E SELVA MARINA UNIT 6 LOT 19 BLK 6 Valuation of Work(Replacement Cost) Heated/Cooled SF Non-Heated/Cooled SF •Class of Work: 0 New ❑Addition ❑Alteration ❑Repair ❑Move DDemo ❑Pool ❑Window/Door •Use of existing/proposed structure(s): ❑Commercial OResidential •If existing structure, is a fire sprinkler system installed?:0Yes X0 No •Will tree(s)be removed in association with proposed project? ❑Yes (Must submit separate Tree Removal Permit) 0 No Describe in detail the type of work to be performed: New shotcrete swimming pool Florida Product Approval# (For multiple products use Product Aooroval Information Sheet) Property Owner Information Name Jay Dodsen Phone Address 1626 Park Terrace West City Atlantic Beach State FL Zip 32233 Email Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Contractor Information Name of Company Equity Pools of Florida, LLC Phone 904-707-4820 Address 2650 Rosselle Street City Jacksonville State FL Zip 32204 Qualifying Agent Joseph Indriolo State Certification/Registration# CPC1459741 Email kelli@equitypoolsfl.com Job Site Contact Number 850-545-7646 Worker's Compensation Insurer OR Exempt XQ Expiration Date 1/3/2026 Architect's Name Email Phone Engineer's Name All Aquatic Engineering,LLC/Nicholas Eckhardt Email nick@allaquaticengineering.com Phone 904-451-0630 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this city/county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. **WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE SITE OF THE IMPROVEMENT BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN A ORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. ,r / L._(Signature of Owner or Agent) Signature of Contractor) Signed and sworn to(or affirmed)before me this I y day of Signed and s to(or affirmed)before me this day of -rit ;te e, a✓,, , 2.-O'2—(1 by. c).. ,-..A Ai foot. ./c1 , -L.. by •S 011i is `Ol to 1 Signature of Notary (,Uit1. f-7)1.4✓""l ti ~Ar Signature of Notary �i" ai" 1,.-1; lik [ ] Personally Known OR [,(j_Produced Identification jt&Personally Known OR [ Produced I.•ntification Type of Identification: 1v )L- Type of 4 .— — — •.— — — I ,..4., i(EL:I 3ROMMER 1ARGE i T 4' ILLI 110AvgR HARGM rr 1 Notary Public•State or:'.oriaa ,...„44,04,i:•..\ ` Notary Polio•State of Florida ( 1 ,if Commission 4*•IH 2E6003 . �}• Commission i MH i4i001 ( orn.r My Comm.Expires Mar 28.2026 Expires Mar 21,2021 ( ionded through National Notary Assn, ..a.�;> My COMM. � Banded the-mall Mat4rul kinks..,♦am 4.4). er 411. • o .0404.Ise s , $ s 41: 44.44ttjt • o I.111.44 mq1c.)%to 4 Atli.de owls astiro.11 MAP SHOWING BOUNDARY SURVEY OF LOT 19 BLOCK 6 AS SHOWN ON MAP OF SEL VA MARINA UNIT NO. 6 AS RECORDED IN PLAT BOOK 34 PAGES 51-518 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTIFIED TO: JAMES W. DUPREE III & MICHELLE D. DUPREE/ FIRST AMERICAN TITLE INSURANCE COMPANY/ J. KEITH SANDS, P.A. /AMNET MORTGAGE, INC 1 , LOT 19 BIZP ^1. • ,NO '10 10 A GONG, IRIVC N •.. •-• .- T u If 1� r I 1 --t VC: �. .. 1 0.2 {1.' ... - \\ i, • - iiliVil . F T.. �.... r, WALK )\'‘). . \\ it ilii `', A ___5...1=- 6' • Tota!Loa•21,659 sf INCE 1'. Existing House and Potel�3494 sf � _ ..,t1 New Pool-484 sf @iil50%-242 sf '1.. 1^IF. New Coping-17 sf • ....._.-.. T n�VII New Pool Equip Pads-32 sf \ NO Y.. 1, ,I y l New Turf=675 sf around pool @0% co r ) 1Uta1 Impsrvloorr3B65.47.*% --- O y 1.8'x.,,' -` f_� \ Wow Z •'••t: > G )..,t' L c LOT 20 i co rry a= -. N7. 1 ' �'C) 1 'I c. 1.3'BLOGWA1-L ,� THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN ON THIS SURVEY THAT MAY BE FOUND IN THE PUBUC RECORDS ON THIS COUNTY. UNDERGROUND ENCROACHMENTS NOT LOCATED THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X'AS SHOWN ON FLOOD INSURANCE RATE MAP 0001 D FOR THE CITY OF ATLANTIC BEACH, FLORIDA, F.I.R.M. MAP DATE 04-17-89. ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS - 6820 SOUTHPOINT PARKWAY, SUITE 1 - JACKSONVILLE, FLORIDA 32216 - 904/279-0088 - LICENSED BUSINESS NO. 3857 Le end THE ABOVE LANDS WERE SURVEYED UNDER MY RESPONSIBLE 1-5 F.F.E.A FINISHED FLOOR ELEVATION SUPERVISION AND DIRECTION, THAT THERE ARE NO ENCROACHMENTS RID. MIND ACOS .PAW cases or ENGNECRS CONC CONCRETE Mt . WETLANDS UNE EXCEPTI IASM SHOWN ANDA THAT THE SURVEY FORTHTHEREON MEETSRID CON. CONCRETE THE MINIMUM TECHNICAL STANDARDS SET BY THE FLORIDA i P. MON PIPE P.R.Y..PERNMMONUMENT REFERENCEALL LP. IRON RIPE POINT OF CBOARD HATER F472 027 PROFESSIONAL / CHAPTERE611017 6, FLORORS AND IDA,STATUTES.PURSUANT TO AMERICAN I.R. IRON Roo P.T. -PERM E rATen TANGENT DISTANCE P.C.R..PERMANENT Of COMMCNTPOINT C CELL ANGLE P.C. -PONT Or CWM SURVEYORS A CHORD L P.R.C..PONT or REVERSE D CLAM SURVEY NOT VALID UNLESS EMBOSSED BY SEAL OF FLORIDA, A ARC LENGTH P.C.C..PONT W COMPOUND GUMC R RADIUS e.RL. DRESTRICTION JAMES D. HARJNo.9 2647 INC. (ACT) ACAUAL P.P.&I. FLORIDAULOBST POKER k UMW CARL S. COURSON, No. 3129 (P) PLAT ADI U.D.E -UNOBSTRUCTED DRAINAGE SCALE t' - 30' R RADIAL LMC EASEMENT E CENTER UNE NOVO .NATIONAL OCOOETIC VERTICAL _9 R/w RIGIR-Or-RAY DATUM - PISKT P.I. .PONT Or NTMSECTION f�.WITNESS B .TOP Of DATE 03-10-OS FLORIDA REGISTERED SURVEYOR AND MAPPER :-8 - I F.B. D.C. 05-450 DR. BY MB DIR. Server\Dwps\2005\05-450 FILE 05-450 ORDER NO. 05-450 t..Lt , --* •,. _. _ . ._ FN[ 1/4 .-'-'• ii,. ____ - ___. . _ _ - ---- 1r _ ,T_____ __ .. t 1 . --• • - , . . , -- 4 CO4 ttiC • i 4 r . ?Rf VEVIAaY 4 . 44 , . c , - •-' .... - cl 4 . ... Z• I - • - ./s . . e 4 . e •-„_-__t _ - _ 4 • --— : . .. 1 ( i • .J., • _-. _. .' ie. - I - . ,..-1 1 U' U\I ? • , A...1 . CP ' I I ,-..t t i - I i , ..- 1 I isnomuj 4---:1-11- --r: .i I 11 r — • COVERED--- ...-. ._ J Ad ENTRY ! _11 • . : i I • tri , ; • ,__ . i ' -'7 • i 44‘- 3 I i I II c 1 i -... ... 3. CCAC, WALK 2 1 ..:.: ll i : . : w . -s ti I ..= '4 it • .... .4 . . 1 = i l'h. ti . 1, ,,. ............. I : • iii 15'r - - 0 3' WIDE BRICK I t - - -- _ (4—PLANTERS • I . • _ 74 ,. ..„ i ir . .-.. ' • , • ••• • • __.-..., FN G 1 ../2” ' P• t NC if) . 0-7. ---- --- / ________ NO ID I ( i PLASTIC FENCE i n T o nT 0 o vi The Dodson Residence , -- 1626 Park Terrace W immi Atlantic Bch, FL 32233 A; - Pool 15'x30', 450SF v0. ' Ni - 3.5' to 6' depth I+ Pool Equipment 42' LED Lights x3 •------- H---- 3(V ° -, — —41'3" 16-5"depth . Fa 0 u.! - a ., \ ® -•s LED Bubbler x2 Main Drain[14 • �� �1 VGB Compliant '. Bar Stools x3 1 0 :� / Returns x4 1 rf i'� 2' f V I O LED Lights x2 'o n n2 5 I i 6' . iR i- . I G'--• Ca Cleaner Line Skimmer 4 —� Scale: 0.14 in. per ft. HAYWARD SW I MCLEAR C200S FILTER ChM Channel Drain 25506 Poolol TRISTAR VS 950 PERFORMANCE COMPARISON FILTER PERFORMANCE DATA w C m 0 "H v C0..^t: 1 M • -_ rV S —:.r ww .,+ .FILTRATION L/) N rV u ��� 9J. 70 . —;•m xw MODEL NL'HBER •iR.TiM71D11 AREA DESIGN FLOW NATE" , I CO-0 = ss �..xw C!OOs NO If MN N' 100GPN/379LPM 0 t0 LL ___.-. :. Area: a25)wz -�' ResMrniie; [!505 DB IN/LIMN tiOGPM It55LPN CD y L u .. IMS.:rtate0.ld' 632..13 ft' 'x 1r�o> 200RfNSBm- 12UGPR�45SLPv 4•� Y ami G. VG;mr. 9,95!ga orts -mpp f--6`,, -----""---Ss C^J` ,� DD b \s W CL V o Er••e cpe: 30 x 15 POOL •^ LO . MORE = m • Dem ry^: 3 E'to a 9'tc 6 D .. Coo^gI"ter or: R 0 25 N 75 IW 125 :SO SIS 200 ,. Coo:"g Area: 94" RPw IGPNI SPECIFICATIONS C. CcraN Mater a: StNY.Trewert r... a NON.NO BRI• I..ow1 .w • NM NAME N4 W MANN NC=MAY m+enllN 1 .. T.Le Lne •6-91 ...,,,_-e......,,......�...f....�......•,._..r.r._... _ • '.1 11444.'{U l i STATE ;. ne Material: T-e.Store,B.Ae... a • :6`:50q o�a �` O D'a rx 1 ''xS57UNAl H,''r ., Irte iorFiriSt1: aeoDie?ecrrD... E1/17/2024 SprN7Ser LJLNlgtr;Sj: ALL AQUATIC ... SOOCI er MV/: LAo LMA.) • ENGINEERING • _ Ealertir Facng: 0 Rl —-_ y� i .......,00.0..- Pd fe0 RedTS: ill W Mr.rwNESF • Pd sea Sear M'r- Minimum pipe size and velocity '_^.0 �. LED B.aBr.n RN)W`RN`m Steps'3ercres 8 Recirculation Pump: «� "M""N'�N)NN' >3"main drain suction @ 96 gpm=4.24 his U • ..='ee..' _ _3 • Step.rear F,: 80-a- >2"skimmer suction line @ 36 gpm=3.51 IUs N Step k•-•reeler 163' >1.5"wall return lines @ 36 gpm=5.82 IUs .•R.....a __... _ 'I)! >2"cleaner line @ 36 gpm =3.51 Ills .- Step Area 6.21 >1.5"bubbler tine @ 30 gpm =4.85 IUs(each) 'au L•d.e•_: " '.^ R S 75 2'et.1 __ L a 1 -'.,.- e.'.•_.-..' e i:ore.8iue_ 4 -- :_ :-e'c33.3ydr& 0 s Owner LM IR.1..r :e'22- 2936 3' 1; I ., 8 . Poo quipment W The Dodson Residence c c L'RPE SOI:S MINIMUM'USIED MUS BE USED,AND SIZES ARE DESIGNED TO NOT .. 0, o 0 MEW THE FOLLOWHIG VEROOTIES: 1626 Park Terrace W ♦ ++ d , -BFT/S PRESSURE SDE OF SKEW Atlantic Bch,FL 32233 0 10 -SFT/SSKTIDN 90E Of SYSTEM 4J ` 2_REFER TO MAM/FACTUREWS INSTRUCTIONS FOR PIPE SIZE REQUIREMENTS AND -Pool 15'x30',450SF , Qj a. MANGE TIN SEN AS IEEDED,WMLt MEETING THE MINIMUM SIZES IN THE TABLE ABOVE. -3.5'CO b'depth 0 C411 o 3.ALL PIPING TO BE RATINGUN SCIEDULE 40 MINIMUM RATING LESS OTHERWISE NOTED- o 4,POOL EQUIPMENT PIPING SIZE TO MATCH THE EQUIPMENT CONNECTIONS,IN NO CASE NkSEIv W EW'Nq - H w C SHALL THE EQUIPMENT PIPING TO BE LESS THAN 2"PIPE 5W. NORM.Y Ilom IryNR.ryytW.IPNa • 5.WALL AND FLOOR RECIRCULATION RETURNS,SPA JET LINES,AND OEANFR UNES4,-!'t:o4k,'...‘ Nd AWN by DWI 404r W.['tJd'N'd No Scale PENETRATIONS THROWN THE POOL OR SPA STRUCTURE SHALL BE 1S'MNIMUM. •1•• P.E.ER BI.DAM NON rim SEMp sale 6.1'CONDUIT TO BE PROVIDED FOR ALL W HT LOCATIONS. ,lT(I/I 2 .111.15 wing a dA N 5IpWN.RN 7.1 ... 'n REFERENCE C'OOESTANOARDS: L STOlE Q�:R, �' •d EM v'N"a 0D. THBR DRAWNGS HAVE BEEN DESIGNED TO BE IN ACCORDANCE WITH THE FOLLOWING CODES: I TQRWF.aE" .Ip•AO Nd Nwlw NA i1 *inane N Dote Jan 2024 -FLORIDA II RDNG CODE 8TH EDITION(2023).RESOENT1AL PRIVATE SWIMMING POOLS '"-:ZZ ELH! NAVIN NNW CO R•11'de A Irk WWI •.- .-_._. SAeet .,•O�NA�� 2024.01.,71 I577B-0SDV Name SM-1 -NATIONAL ELECTRIC CODE NEPA 70(2021) c m OWrn N (/I w N DEtEMt SDIDCl1FLL NOTATOR_ 10 C m .IEHAR SONG ASSIOINIIEREN -J ..R ARA5IM AOS EYADEW O (O l.L +CONCRETE COVERAGE B RESNORDE EIO rN 1DOTNG8 Q N L 4'NALL 011615 h' V •R PSI/WW1 MADE coRCIETE 11../21'MY {.J Y d •RAR MI.LAPPED 010 SAF D..E rESm m Q1 ° u •O D C NlN DEPTH PER L N a+ PLAN a, Q DECK(PAVER MICK(PAVER POOL BEAM THICKNESS OR CONCRETE) NA71RIJE v1 ....EIN ON � Timm pODL R-WATERLINE _ BEE PLAN - JOIN 11 DECK(PAVER OR r POS !tM r-�� CONCRETE) pQ�y6 NAMI LINE t STS _ L.` 11:4 OR DEPTH L iF"`sl ON14�'�'ot+ '� (2).3 CONT.BOND BEAM PER PLAN ' l IIII�I1I13 1`1'SIDNAIEe+r' 7 AI► t 3 REBAR @ 10"OC SZ r MKILE ' 1�17�202a 4 EACH WAY CONTINUOUS IN POOL SHELL 'L g RERAN PLACEMENT .. _ .T }-__ All AQUATIC r I o SAME AS POOL WALU -- rj S7 ENGNEERMIR 1 MIN.POOL WALL 6 FLOOR SECTION c ' \ '. r POOL SMELL THICKNESS ' POOL I3 RERAN HOOKS AT CORNERS,— �, .MIN.POOL STRUCTURE FOUR PER BARSTOOL R.trtr FLOOR A..YW.NFf>!. THICKNESS nclral.r.N,A..ty --_ e ••3 RERAN @10-OC EACH WAY .I. Is ...low..aVIEWT. CONTINUOUS IN POOL SHELL SUN SHELF SECTION I LL POOL WALL/FLOOR SECTION SWIMOUT SECTION 1?'.1- e: 1?_1- 1/2",.• rA o S DECK(PAVER r POOL BEAM `/ g OR CONCRETE) THICKNESS i—WATERLINE c n m SEE PLAN ` + ILVOINUMEr DETM TYPICAL FOR BARSTOOL _ 1 F AND_TA$IEl�QRTCOLUMN .. -_ - - ," _ - . •.. �TIIp, T.O,. - AS NEEDED TO - 1'O` fl TIF ro (TrP1 v A[COMMOOATF FINISH t t r _—IN W (Q IS"DIA CARDBOARD VERTIEAI REBAR fAOM m L SONOTUBE FORM B1116TOO110 fAN OUR f 3 REBAR(LD 10-OC PER HOMEOWNDK II 6 RACIALLY AS SHOWN EACH WAY CONTINUOUS a U PN (2'MIM.9'MA7Q �§ IN POOL SHELL t A cv 0 co TYPKAI POOL111 FOUR MIN VERTICAI RENFORCEMENT PER POOL RVAIN BARS RN f1 MS `_PDOL FLOORSTEP HEIGHTS n e ". - - - L Y I WALL/FLOOR SECTION THS • TO N N SHEET TO BE UNIFORM 12'DIA.CARDBOARD .. SONOTUBE FORM �� SUN SHELF W/STAIRS SECTION AoBAN OIA ovelEAP late Jan 2024 SONOTUBE BARSTOOL DETAIL 1/2--I- 1/r=r ,W` SM-3 C en ANSI/APSP 5&7,Specifies three methods for determining the maximum system flow rate. TDH Calculation Options ANSI/APSP/ICC Worksheet 0 3 ry The following simplified TDH calculation Is one of the methods speecified. (For each Pump) Swimming Pool Energy Efficiency Compliance Information N `E' m Check me Note:These Requirements Apply ONLY to the Filtration Pump a --+ Simplified Total Dynamic Head(TDH)Calculation Worksheettj Simplified Total Dynamic Head(STDH) Maximum Filtration Flow Rate Calculations O t0 " Complete STOH Worksheet-Fill in all Blanks I_. Li Determine Maximum System Flow Ratere 0 -v aa Minimum Flow Rate Required:35 gpm per skimmer(required:1 skimmer per 800 sq ft of surf.area) Total Dynamic Head(TDH) Pool Water Volume /3617= gpmdiRration flow rate Complete Program or other cal..Fill in U CO Co 450 3 g 951 required blanks on worksheet&attached Is there an Auxiliary load on the filtration pump?Yes_NO Qj a. u 1.Calculate Pod Volume X %7.48(gal./cubk foot). wkulations •O ,rt.,/ c t9tanwe I ling Maw Mawrktamend 0 2.Determine preferred Turnover Time in Hours: - X60(min/Irotlr). 360 Maximum Flow Capacity R so,what is the auxiliary flow rate gpm L ,.-1 m 711/iiiir- (use 36) CI'''''''''''') of the new or replacement pump IZ Q 360 27 64 + 60 96 Maximum Flow Rate gpm(maximum auxiliary pool 3.Determine Max Flow Rate / loads or the filtration flow rate,whichever is eater.) No.".meawy Omar imam atr.+Rae) (F.r,+rM=Raw Fb.morel Notes: Br ay 1.If a variable speed pump is used,use the max The pool filtration flow rate shall not be greater than the rate 4.Spa lets: X GPM per jet= Rey 0��) flow rate pump flow in calculations. needed to turn over the pool water volume In 6 hours or 36 gpm _ `7 Ino diets) (Jet Row) 2.For side wall drains,use appropriate side wall ` Ngtaa PPP oP whichever Is greater.This means that for pools of less than (For Sine Pump pod/spa combo,use the higher of No.3 or No.I In the following cakulnlom to,the pox'&Spa) drain flow as publishedmanufacturer. 1' � by 13,000 gallons,the pump shall be sized to have a flow rate of 36 s7ATE Determine Pipe Sizes: 3.Insert manufacturer's name and approved gpm or less. ' ':1oaic.. maximum flow. '-s•+'mSSA11 ,../ Branch Piping to be inch to keep velocity @ 6 fps mat.at_gpm Maximum System Flow Rate 4.See installation Instructions for number of Suction Pipe size @ 6 fps 3 inch 1/17/2024 Suction Ping to be inch to keepvelocity @ 8 fps max.at Maximumports.Inl be used. Piping gpm System Flow Rate 5.In-Floor suction outlet cover/grate must Return pipe size @ 8 fps 25 inch Return Piping to be inch to keep velocity te SO fps max.at ,�gpm Maximum System Flow Rate conform to most recent edition of ASME/ANSI Filter Factors:(Cartridge.375)or(OE 2)or(Sand 15) ALL AQUATIC A112.19.8 and be embossed with that edition �rTENGNE�RIFIG Determine Simplified TOM: approval. / 375 U ULl 1.1tE 6.Pump,Filter,and Heater make and model (now rate) (AOMIaOv) (minimum Mer she) 1.Distance from pool,to pump In Ft: 40 cannot change,and equipment location cannot be moved closer to the pod without submitting Filter Make/Size . ' ,...,2 00S Cartndge,200 SF arwra+nam MU 2.Friction loss(in suction pipe)in 3 inch pipe per 1 ft.M gam a -04 (from pipe flow/frktion loss un) a revised plan and TDH calculation worksheet for t.r wan.n wenn rt 3.Friction loss(in return n 2.5 inch -08 ham pipe now/hktlori loss rhea) approval. Backwash valve?Yes_No_(if yes,must be 2 inch min) +w+re+dasra pipe) pipe per 1 ft. 4. x .04 _ Pump Selction from APSP database on Curve A(Less than 17000 "' tv..rtanmener watr4Aa MO -nor,,nnnr et gallons)or C(greater than 17,000 gallons)(circlesp e one) Y 5. X .08 eagi Model_ ,vard 2.7 VSP peyna amen rM pis atrr.4neawni tt.Ra+r+nra ida114.1.14e.Con,*Cron �' �° TDH In Piping 11,48 .. ..-,. ., .. ,...� li Flow and Friction Loss Per Foot Filter loss in TDH(from filter data sheet) 2 Flow Rate(low speed) gpm! 1725 rpm - n - ' C (Schedule par pi od le4o pe) Heater loss in TDH(from heater data sheet) 5 C s Total all other losses 2 Flow Rate(high speed) gpm @ 2400 rpm Velocity-Feet Per Second (not required if no auxiliary load on filtration pump) o Pipe Sia 6 FPS 8 FPS SO FPS Total Dynamic Head(TDH) 20.48 , 8F 15" 37 gpm .08' 50 gpm .14' 62 gpm .21' Pump Controls ' • ' 2" 62 gpm .06' 82 gpm .10' 103 gpm .16' Standard time dock 2 _ ` - �i / speed time dodo a other 25" 88 gpm .05' 117 gpm .08' 148 gpm .13' Date '+' 3" 136 gpm.04' 181 gpm .07' 227 gpm .10' .,, • 4" 234 gpm.03' 313 gpm .05' 392 gpm .07' Heater Model ring in ilealofp , Notes:suction piping in front of pump Inlet must be 4 pipe 6" 534 gpm.02' 712 gpm .03' . - diameters in length.Must have 18"straight pipe after the later - Selected Pump and Main Drain Cover: Contractors Signature for solar. y+ 41 Pump selection :, pump VSI' using pp curve for TDH&System Flow Rate = t (Pump model and dm In HP) Main Drain Cover .l;lne' (SyAem Flow Rate most not exceed approved corer now(RN) Print Name ENQNEER'6 STATE/JEW; r f 1,odeO INFORMATION INEERA THIS SHEET HAS BEEN DRAWINGS RO BY - L 0 Notes:Minimum system flow based on minimum flow per skimmer of 35 gpm. ENGINEER AND IS BASED ON THE Ul05 PROVIDED ALBY VI Certification Number THE BUILDER.ENGINEER HAS VERIFIED THE SAMPLE TOTAL DYNAMIC HEAD CALCULATIONS SHOWN THIS SHEET WITH Determine the Number and Type of Required In-Floor Suction Outlets: ENGINEER'S POOL CALCULATIONPROGRAM. ENGINEERS - ( that ate,) CALCULATIONS COVER THE POOL RECBWCULATHON,SPA JET Sale; Nole va al0 0-w-- 3' —�0 Suction Outlets @ Won max.flow(see note) Telephone Number FLOW,AND/OR FEATURE FLOWS,JECTFOR SINGLE OR MULTIPLE + .. + +..• Date Jan 2024 Suction Outlets! gpm max.flow(see rote 3) PUMP SYSTEMS.EACH PROJECT B ENGINEERED SPECIFIC TO • Wel.. "� gree 0 Q Q THE POOL SHOWN. Port �w cwno..0 0 I 1 Channel Drags! 308 gprnw/ ports(see notN) „"„,.„",•w,�",,,,,,,, """ Sheet SM'2 Name • 0 HAYWARD® VS Omni We Build Better. Variable-Speed Pumps with Smart Pool & Spa Control. INDUSTRY-LEADING ENERGY SAVINGS PLUS TOTAL POOL & SPA CONTROL 9:41 ..iI - Pool Spa CONTROLS Filter Pump Heater Mt.tillriii Spillo,er Set Point 85" Orr On Lights Chlorinator Aqua Green ORP 680mv pH Spillover 7' 1414111 )1 44-0000 -- •mss Off War— . Menu EXPERT LINE' lO ONLY FROM POOL PROS O 3+YEAR PARTS&LABOR WARRANTIES' 'When sold by a Totally Hayward''Partner.Exctus.ons.other t rrrs anri cnndaions may apply-vesd hayward corn/expert'or dela.::; • w k+- yy�� ��t` "",:sty q 4 ,,.,,'' ' '* :41'''' a,'. 1<... x y . ,4 !` qy� 9' { .! 0,-: _ to r + "' . '-� • .x#' hViikel b tom3 '`• !. 4 s ks ► "'y ---, ! *' lk,. 11- .4,... 4.ka iv, i c _.2.:-.• l / : . ar t T is 1" a w 4 • !! -?..• R t" >. � •C 9 -',e'-k':'•‘-,4,:•4'.4:, *� s4e� b J"a ,:a1'- ',. r e z :, 4 T � 1 •,,„,..---r.ig ,r m -,-",-.47-.7-- Alt sige ? "', r o J.Ys . i. „, .sa s Jxf`uyt r' ^ i' .ff y lk _41 .. • `tea '!. 4 4w. . '} . - :: # • �"L t 1 'Aa ', sTr -.,k.wt+ .,A ss% 1 R • } �. ..._ u. � s.• • -' y J� 3jy • -. 1y 3 , . !,' S ri nf'y 3y 5 ,. -V �. 5 fie- 4. %{ • tk TY k ` 4 +M" F � � r -i 1 1,0 iJ,J J.f- { 3. ,i ` .. " dn. 4f"7 t ' -� .r iM ,p d'fk.L� '3t. � v m . d_ , fi> „ S !,f' - Cy.4'' a A•' Q lc • • 'O , • 't J4.mo---41..,4t..17-,-...., A1 • f y k. P N T ''`-7.-N-.‘...:, ' '" S 1 F y L • • • z_401,4-.....„..s a i f .-*- V' a^-' *' ' 'tr ark .i +� ,ori &:•t• ar.e�� 4�rt .yi.•.. F„114:**.*: �t i" 7. x'31 t • 5f:,.. .S'-0ln •°R' ./y. :..'bF X41, .ag c e:, * a n Jt. ,YyiE41i>i•., Simple five-step installation for pool professionals. Installing VS Omni®is a simple five-step process.With fast,intuitive configuration and compatibility with most pool equipment brands, it's the most trade-friendly smart control solution on the market. 1 Mount Wiring Base Unit and Control Pad. 2 Replace pump. Detach power from the filter pump(or other high powered equipment)and make wiring connections to the Wiring Base Unit.Run the supplied 6-ft whip from the Wiring Base Unit to the equipment. 3 Replace existing light switch with Omni Smart Relay or install Smart Relay in line with controlled equipment. 4 Connect control wires from the controlled equipment—including Control Pad,Smart Relay comm cables,VS pump comm cables, sensors and actuator cables—to the Wiring Base Unit. 5 Pair Wi-Fi®and configure Control Pad. Control Pad can be wall-mounted,features an intuitive touchscreen interface and maintains pool pad control even without internet connection • 8` Wiring Base Unit offers connections • for both high and low voltage wiring for easy configuration with different types of equipment OmniLogic App offers total control from a anywhere on iPhone®,iPad®,Apple Watch®,and Android® Smart Relay converts existing equipment, such as Hayward®single-speed pumps and lights,for use with VS Omni(can connect up to three Smart Relays for additional control) 406, _ 11 04.1 1011 i. ,I, tis' ' 14 • , i 4 , 1111114*" am` '. 110 p )1116400-4iiik WHERE CONVENIENCE MEETS COOL. VS OMNI' IS THE EASIEST WAY TO ADD SMART CONTROL TO NEW OR EXISTING POOLS & SPAS. In addition to industry-leading variable-speed energy savings,VS Omni offers control of a full range of pool and spa equipment right from a smartphone or tablet.VS Omni installs in just a few hours and is easy to configure with existing equipment and accessories—like Hayward®ColorLogic®lights and AquaRite®salt chlorination systems—saving both time and hassle. When it comes to backyard control, VS Omni is the total package. VS Omni can control virtually every kind of pool and spa equipment, including pumps,heaters,lighting,sanitization,water features and more, as well as up to two Hayward valve actuators,so spas can be turned on and off at the touch of a button. < Cenl , r‘.. .F . .. .__, Is:Pump Hc.., POOL I rye.,.. 5, Irf,s.r;a„. Ivslir Tj. (� Gea m (J�j JI t 0 63} ..� u.., Ypntt t..A. l,.YYle, t .. w HLWIRELESS Wireless remote control(sold separately) PUMPS HEATER LIGHTS SALT SYSTEM CLEANER WATER FEATURES SPA Control Adjust Dim,schedule Monitor salt& Schedule Set schedules Switch to variable-speed temperature or change colors set chlorination cleanings &themes spa mode ALEXA®, ASK HAYWARD TO TURN ON THE SPA. VS Omni works with popular home automation systems like Amazon°Alexa'and Google Home?making it a seamless addition to any smart home. SAVE UP TO 90% ON ENERGY COSTS' , • ENERGY STAR • INDUSTRY-LEADING ENERGY EFFICIENCY VS Omni'pumps reduce your customers' energy costs by up to 90%',saving up to$1,500 annually. PERFORMANCE YOU CAN COUNT ON Featuring a permanent magnet,totally enclosed fan-cooled motor,VS Omni pumps run cooler and more efficiently,ensuring reliable service season after season. QUIETER THAN EVER BEFORE VS Omni pumps reduce noise and operate up to 50%quieter at maximum speeds than leading competing models. SIMPLE INSTALLATION AND MAINTENANCE VS Omni pumps are designed with easy-access top-mount wiring that makes for speedier installation.Their see-through no-rib strainer basket makes cleaning faster,too. NEXT-LEVEL POOL LIGHTING When VS Omni pairs with Hayware ColorLogic®tights,exclusive OmniDirect Mode'unlocks, offering additional color options,dimming control and more. WORKS WITH MOST EQUIPMENT BRANDS Smart control components are compatible with most pool equipment brands for easy setup and configuration. 'Save up to 90%on energy costs versus single-speed pumps SMART SOLUTIONS FOR EVERY POOL. ilippr „iip ,..,„ Alior TRISTAR"VS 950 OMNI" TRISTAR'VS 900 OMNI° SUPER PUMP"VS 700 OMNI" MAXFLO VS'500 OMNI" r Replaces single-speed n Right-sized to replace most . Drop-in upgrade for Super . Drop-in upgrade for MaxFloV' pumps up to 3 HP pumps up to 2 HP max-rate Pump models up to 1.5 HP models up to 1.5 HP Up to 90%energy savings .Up to 90%energy savings .Up to 80%energy savings .Up to 80%energy savings over single-speed pumps over single-speed pumps over single-speed pumps over single-speed pumps 4-year extended warranty* .3-year extended warranty* .3-year extended warranty* .3-year extended warranty* SPECIFICATIONS WEIGHTED I 1 MODEL ENERGY UNION/ PRODUCT NAME NUMBER TOTAL HP FACTOR(WEF) VOLTAGE SPEED RANGE PORT SIZE 1 WARRANTY* TriStar VS 950 Omni HL32950VSP 2.70 10.1/7.3 115V/230V 600-3450 RPM 2"x 2.5" 4 years TriStar VS 900 Omni HL32900VSP 1.85 12.9/8.3 115V/230V 600-3450 RPM 2"x 2.5" 4 years Super Pump VS 700 Omni HL2670020VSP 1.65 11.7/8.6 115V/230V 600-3450 RPM 2" 3 years MaxFlo VS 500 Omni HL2350020VSP 1.65 10.7/10.2 115V/230V 600-3450 RPM 1.5"x 2" 3 years OmniHubm Smart Relay Kit HLH485RELAY N/A N/A 120V/230V Single N/A N/A 3 years Phase OmniHub Spa Kit HL485SPAKIT N/A N/A N/A N/A N/A 3 years AquaRite Omni HLAQRPCB N/A N/A N/A N/A N/A 4 years Daughter Board •When sold by a Totally Hayward•partner.Exclusions,other terms and conditions may apply—visit hayward.com/expert for details. 00 HAYWARD.COM/VSOMNI 011 . hayward.com » 1-888-HAYWARD Watch the VS Omni pumps in action Pumps » Fitters » Heaters » Sanitization » Automation * Lighting >, Water Features » Cleaners » Safety Hayward,Hayward&Design,the H logo,AquaRite,Colorlogic,Expert Line,MaxPlo,Maxrlo VS,Omni.OmniHub,OmniLogic,Super Pump,Totally Hayward,TriStar,VS Omni and We Build Better.are registered trademarks and OmniDirect Mode is a trademark HAYWARD of Hayward Industries,Inc.Google Home•and Android.are trademarks of Google.LLC.,Amazon"and Alexa•are trademarks 0 of Amazon Technologies,Inc.,and iPad•and iPhone•are trademarks of Apple Inc.None of these companies are affiliated with Hayward Industries,Inc.nor endorses this product.All other trademarks not owned by Hayward are the property of their respective We Build Better: owners.Hayward is not in any way affiliated with or endorsed by those third parties.m 2023 Hayward Industries,Inc. LITVSO MNIBR023 HAYWARD HeatPro. Series LONG-LASTING COMFORT AND EFFICIENCY Heat Pumps f WITH POWERFUL CORROSION RESISTANCE IC HAYWARDOggia®P • XHAYWARD ••O em - HP r _ '..... a..:x^ g ey * a r `a` _ ; ra , , .;Fy w • . .. _,,�, ` y •;t4tql fy , , haI Stt* #4.7.- .4. b- �3 s Si moi. - .. ° i 7- I," ,"r ,�- i'A �' t } of k,p 1.; y r µ,., 3-‘,7#.4'.''. +• : ":: - ' " :� � p °0 44. t': ' . i TSL _ ... ' js411!:„,:,...„*.. ,i "'At• rF . r �E31 " +. fiY rr • d . �ya 7 � - t 4x L ' „ a'`V "`r .*� • '�� "i.' +a'^:j "'��� `- � .s '�w. � rte '''4 te .= t a�, tle 44.0 iti, s *144t 000 41**41 • ��r '. ▪ �'.. ,==.= ,,y� ) fix' `eF .yy n "9• r fid':• • Ot �• y� y. f,,, A' ap , fi • t,� ,o *t''. . t' r•� .r i 1F • a , • Y $p. y'¢ `.. .x ,K t_ ' ,..Y.41°,&`," F ..21 ''„ `'s s47, `ac r .`, } . • re .-'e, -{.,¢ to -,yam F., `.'.,'i! ;. A.. ..'.4 'Y • .:¢ YS, c ', .3..,. eh. _ k .�' .tit COMFORT YOU CAN COUNT ON . • • t • t `k Y 4 Polyethylene screen protects the evaporator coil to maintain peak efficiency 4111111111111111110$1- Acoustic compressor cover reduces noise • `"a"` Ultra Gold evaporator fin resists corrosion .a for years of reliable performance . Titanium counter-flow heat exchanger ensures maximum heat transfer Injection-molded UV-resistant body panels are impervious to corrosion and deterioration Stainless steel hardware provides added strength and durability Compact,lightweight design makes installation easy in any environment HeatPro® heat pumps provide longer-lasting performance. Don't let cool temperatures cut your pool season short. HeatPro heat pumps are the easy,efficient and economical way to get in the water sooner and stay in longer. EXTREME CORROSION RESISTANCE With the industry's only Ultra Gold corrosion-resistant evaporator fin, HeatPro heat pumps offer unparalleled durability,even in harsh coastal environments. DESIGNED FOR PEACE AND QUIET HeatPro heat pumps'profiled fan blade and heavy-duty scroll compressors ensure efficient air flow with minimal noise, making any backyard environment instantly more relaxing. EFFICIENT FROM THE INSIDE OUT A titanium counter-flow heat exchanger ensures maximum heat transfer and helps reduce energy costs by up to 70%—and with powerful corrosion resistance,HeatPro heat pumps will keep saving you money for seasons to come. THE HOTTEST SOLUTION FOR COOLER CLIMATES. Fluctuations in temperature can present a challenge for heat pump performance—that's why HeatPro Low Ambient heat pumps are designed to excel when the climate gets cooler.They continue to heat at temperatures as low as 40°F,so the pool stays warm and comfortable even when it's chilly outside. allgalisWrA on. -- - _,_ MODELS TO FIT A RANGE OF NEEDS iiiikeisiii HAYWARD°HEATPRO° HP21004T HP21004TC HP21124T HP21104T HP21254T HP21404T HP31204T I HP21404TC HEAT PUMPS LOW HEAT/COOL LOW AMBIENT AMBIENT BTU HEATING PERFORMANCE 60°F Ambient Air,80°F Water, 90,000 90,000 110,000 110,000 125,000 140,000 1120,000 140,000 80%Relative Humidity 80°F Ambient Air,80°F Water, --_.._..._.._._._._1_-__..__.......-_.._______ 63%Relative Humidity 85,000 85,000 107,000 105,000 120,000 130,000 110,000 130,000 50°F Ambient Air,80°F Water, 59,000 59,000 75,000 75,000 80,000 85,000 78,000 85,000 63%Relative Humidity HEAT Operating Temperature°F 50 40 50 50 50 50 50 40 COEFFICIENT OF PERFORMANCE(COP) 80°F Ambient Air,80°F Water, 5.7 1-5.7 �_-5.7 �_- 5.7 5.7 5.7 5.7 5.7 80%Relative Humidity 80°F Ambient Air,80°F Water, 5.5 5.5 5.4 5.2 5.5 5.5 5.4 5.5 63%Relative Humidity 50°F Ambient Air,80°F Water, 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 63%Relative Humidity Electronic Temperature Control Yes Yes Yes Yes Yes Yes Yes Yes Thermostat-Dual(Pool and Spa) Dual Dual Dual Dual Dual Dual Dual Dual kW Input 4.6 4.6 5.7 5.7 6.4 7.2 6.2 7.2 Voltage 240/60/1 Minimum Circuit Amps 38 38 42 42 42 42 48 42 Minimum Overload Protection 40 40 50 50 50 50 50 50 " Maximum Overload Protection 60 60 60 60 60 60 60 60 Water Flow Rate(GPMI 30/75 30/75 30/75 30/75 30/75 30/75 30/75 30/75 Recommended Minimum/Maximum Plumbing Connection 2"x 21/2"Unions Refrigerant R410A Dimensions finches)W=Width, 301/4 W x 301/4 W x 301/4 W x 311/4 DIA x 301/4 W x 301/4 W x 30V/W x 301/4 W x D=Depth,H=Height,DIA=Diameter 34 D x 37 H 34 D x 37 H 34 D x 44 H 40 H 34Dx37H 34 D x 44 H 34Dx37H 34 D x 44 H Net Weight fibs.) 230 230 245 245 245 280 250 280 Shipping Weight(lbs.) 270 270 285 285 285 320 290 320 °BTU and COP Ratings in Accordance with AHRI 1160 Performance Test Standard * hayward.com ° 1-888-HAYWARD Pumps » Fitters » Heaters » Cleaners » Sanitization » Automation » Lighting A Water Features » White Goods Hayward,Hayward Design,the H logo and HeatPro are registered trademarks of Hayward Industries,Inc.All other trademarks �� HAYWARD' not owned by Hayward are the property of their respective owners.Hayward is not in any way affiliated with or endorsed by those third parties.®2019 Hayward Industries,Inc. LITHTPR020 ISCSioo Rev D (:) HAYWARD® SwimClearT" CARTRIDGE FILTER Owner's Manual R NOW EGISTER to extend your WARRANTY Models CiooS, C15o5 and C2ooS see track of manual for details Contents Product Specific Warnings.........2 Introduction................................4 Installation..................................4 General Warnings. Replacement Parts.....................6 Warranty&Registration............8 IMPORTANT SAFETY INSTRUCTIONS Basic safety precautions should always be followed: failure to follow instructions can cause severe injury and/or death. AThis is the safety-alert symbol.When you see this symbol on your equipment or in this manual, look for one of the following signal words and be alert to the potential for personal injury. AWARNING warns about hazards that can cause serious personal injury, death or major property damage and if ignored presents a potential hazard. ACAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property damage and if ignored present a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe. The NOTICE label indicates special instructions that are important but not related to hazards. SAVE THIS INSTRUCTION MANUAL Hayward Pool Products 400 Connell Drive, Suite 6ioo, Berkeley Heights, NJ 07922 Phone: (9o8) 351.5400 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1 0 HAYWARD, A WARNING -Read, understand and follow all instructions in this owner's manual and on the equipment.Failure to follow instructions can cause severe injury and/or death. A WARNING -Suction Entrapment Hazard. Suction in suction outlets and/or suction outlet covers which are,damaged,broken,cracked,missing,or unsecured can cause a severe injury and/or death due to the following entrapment hazards: Hair Entrapment-Hair can become entangled in suction outlet cover. ® Limb Entrapment-A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged,broken, cracked,missing,or not securely attached can result in a mechanical bind or swelling of the limb. Body Suction Entrapment-A negative pressure applied to a large portion of the body or limbs can result in an entrapment. Evisceration/Disembowelment-A negative pressure applied directly to the intestines through an unprotected suction outlet ® sump or suction outlet cover which is,damaged,broken,cracked,missing,or unsecured can result in evisceration/ disembowelment. Mechanical Entrapment-There is potential for jewelry,swimsuits,hair decorations,fingers,toes or knuckles to be caught in an ® opening of a suction outlet cover resulting in mechanical entrapment. AWARNING -To Reduce the risk of Entrapment Hazards: • When outlets are small enough to be blocked by a person,a minimum of two functioning suction outlets per pump must be installed. Suction outlets In the same plane(i.e.floor or wall),must be Installed a minimum of three feet(3') Ii meter] apart,as measured from near point to near point. � • Dual suction fittings shall be placed in such locations and distances to avoid"dual blockage"by a user. • Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. • The maximum system flow rate shall not exceed the flow rating as listed on the suction outlet cover. • Never use Pool or Spa if any suction outlet component is damaged,broken,cracked,missing,or not securely attached. • Replace damaged,broken,cracked,missing,or not securely attached suction outlet components immediately. • In addition,two or more suction outlets per pump installed in accordance with latest ASME,APSP Standards and CPSC guidelines,follow all National,State,and Local codes applicable. • Installation of a vacuum release or vent system,which relieves entrapping suction,is recommended. AWARNING -Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction outlets can result in an increased potential for suction entrapment as described above. AWARNING -Failure to keep suction outlet components clear of debris,such as leaves,dirt,hair,paper and other material can result in an increase potential for suction entrapment as described above. AWARNING -Suction outlet components have a finite life:the cover/grate should be inspected frequently and replaced at least every seven years or if found to be damaged,broken,cracked, missing,or not securely attached. ACAUTION -Components such as the filtration system,pumps and heater must be positioned so as to prevent their being used as means of access to the pool by young children. To reduce risk of injury,do not permit children to use or climb on this product. Closely supervise children at all times. Components such as the filtration system, pumps,and heaters must be positioned to prevent children from using them as a means of access to the pool. 1A WARNING -Hazardous Pressure. Pool and spa water circulation systems operate under hazardous pressure during 0 start up,normal operation,and after pump shut off. Stand clear of circulation system equipment during pump start up. Failure to follow safety and operation instructions could result in violent separation of the pump housing and cover,and/or filter housing and lock ring due to pressure in the system,which could cause property damage,severe personal injury,or death. Before servicing pool and spa water circulation system,all system and pump controls must be in off position and filter manual air relief valve must be in open position. Before starting system pump,all system valves must be set in a position to allow system water to return back to the pool. Do not change filter control valve position while system pump is running. Before starting system pump, fully open filter manual air relief valve. Do not close filter manual air relief valve until a steady stream of water(not air or air and water)is discharged. eA WARNING -Separation Hazard. Failure to follow safety and operation instructions could result in violent separation of pump and/or filter components. Strainer cover must be properly secured to pump housing with strainer cover lock ring. Before servicing pool and spa circulation system,filters manual air relief valve must be in open position. Do not operate pool and spa circulation system if a system component is not assembled properly,damaged,or missing. Never operate or test the circulation system at more than 5o PSI. Do not purge the system with compressed air. Purging the system with compressed air can cause components to explode,with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI),high volume blower when air purging the pump,filter,or piping. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 2 • • ., �t�!Y �j{ ,ply • • :i t. • • Y.'. '•'z;2.. _ r• 1, -. ' .. ti: p:,n >..:, - ani... .. r c' .t�'. ii" _. tt.c�-� )y' . • 1. .� .. r _ 0 HAYWARD 0 A WARNING -Risk of Electric Shock. All electrical wiring MUST be in conformance with applicable local codes, regulations,and the National Electric Code(NEC). Hazardous voltage can shock,burn,and cause death or serious property damage. To reduce the risk of electric shock,do NOT use an extension cord to connect unit to electric supply. Provide a properly located electrical receptacle. Before working on any electrical equipment,turn off power supply to the equipment. To reduce the risk of electric shock replace damaged wiring immediately. Locate conduit to prevent abuse from lawn mowers,hedge trimmers and other equipment. Do NOT ground to a gas supply line. AWARNING -Risk of Electric Shock.Failure to ground all electrical equipment can cause serious or fatal electrical shock hazard. Electrically ground all electrical equipment before connecting to electrical power supply. AWARNING -Risk of Electric Shock. Failure to bond all electrical equipment to pool structure will increase risk for electrocution and could result in injury or death. To reduce the risk of electric shock,see Installation instructions and consult a professional electrician on how to bond all electrical equipment. Also,contact a licensed electrician for information on local electrical codes for bonding requirements. Notes to electrician: Use a solid copper conductor,size 8 or larger. Run a continuous wire from external bonding lug to reinforcing rod or mesh. Connect a No.8 AWG(8.4 mm2)[No.6 AWG(13.3 mm2)for Canada]solid copper bonding wire to the pressure wire connector provided on the electrical equipment and to all metal parts of swimming pool,spa,or hot tub,and metal piping(except gas piping),and conduit within 5 ft.(1.5 m)of inside walls of swimming pool,spa,or hot tub. IMPORTANT-Reference NEC codes for all wiring standards including,but not limited to,grounding,bonding and other general wiring procedures. AWARNING -Risk of Electric Shock. The electrical equipment must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI,push the test button. The GFCI should interrupt power. Push reset button. Power should be restored. If the GFCI fails to operate in this manner,the GFCI Is defective. If the GFCI interrupts power to the electrical equipment without the test button being pushed,a ground current is flowing,indicating the possibility of an electrical shock. Do not use this electrical equipment. Disconnect the electrical equipment and have the problem corrected by a qualified service representative before using. ACAUTION - HAYWARD®pumps are intended for use with permanently-installed pools and may be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently-installed pool is constructed In or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool Is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. AWARNING -Risk of Hyperthermia.To avoid hyperthermia the following"Safety Rules for Hot Tubs"are recommended by the U.S.Consumer Product Safety Commission. 1.Spa or hot tub water temperatures should never exceed 104°F[4o°C].A temperature of 100°F[38°C]is considered safe for a healthy adult.Special caution is suggested for young children.Prolonged immersion in hot water can induce hyperthermia. 2.Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness,which could lead to unconsciousness and subsequently result in drowning. 3.Pregnant women beware!Soaking in water above ioo°F[38°C]can cause fetal damage during the first three months of pregnancy(resulting in the birth of a brain-damaged or deformed child).Pregnant women should adhere to the loo°F[38°C]maximum rule. 4.Before entering the spa or hot tub,users should check the water temperature with an accurate thermometer;spa or hot tub thermostats may err in regulating water temperatures by as much as 4°F(2.2°C). 5.Persons taking medications,which induce drowsiness,such as tranquilizers,antihistamines or anticoagulants, should not use spas or hot tubs. 6.If the pool/spa is used for therapy,it should be done with the advice of a physician.Always stir pool/spa water before entering the pool/spa to mix in any hot surface layer of water that might exceed healthful temperature limits and cause injury.Do not tamper with controls,because scalding can result if safety controls are not in proper working order. 7.Persons with a medical history of heart disease,circulatory problems,diabetes or blood pressure problems should obtain a physician's advice before using spas or hot tubs. 8.Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above normal body temperature of 98.6°F[37°C].The symptoms of Hyperthermia include:drowsiness,lethargy,dizziness,fainting, and an increase in the internal temperature of the body. The effects of Hyperthermia include: 1. Unawareness of impending danger. 2. Failure to perceive heat. 3. Failure to recognize the need to leave the spa. 4. Physical inability to exit the spa. 5. Fetal damage in pregnant women. 6. Unconsciousness resulting in danger of drowning. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 3 r :: t. V's.,'t. rA 'yy...ya ry • . ,y ;t14.. i ' J: HAYWARD GENERAL INFORMATION The SwimClear filters are high performance swimming pool filters with a residential filtration rating of up to 7200 gallons (27 kL) per hour.Manufactured from durable,corrosion-proof material,they are designed for continuous or intermittent operation,for installation above or below the pool water line,for fresh or saltwater swimming pools or spas.SwimClear filters utilize a reusable single element,reinforced polyester filter cartridge to provide a high degree of water clarity with absolute minimum care.Their unique design is such that no tools are needed to remove or replace the cartridge in the filter assembly.Simply unscrew the lock ring, lift off the filter head and remove the cartridge. It's that easy. PUMP SELECTION AND LOCATION To power your SwimClear filter,select a continuous duty pump designed for swimming pool or spa service. It is important to first determine where your pump and filter will be located. If above the water line,a self-priming pump must be used.Self- priming pumps such as Hayward's Super Pump®,Super IlT"",or TriStarTM have the ability to lift water from a lower level and prime automatically. Select a pump appropriate for your application.Take into consideration:operation of hydrotherapy fittings,automatic cleaners,required turnover rates and losses in the system.A dealer can help you select the proper size pump for you system. FILTER LOCATION 1. Since plumbing fittings offer a resistance to water flow,position the filter as close to the swimming pool as local codes allow. Keep the number of fittings to a minimum.Select a well-drained area,one that will not flood when it rains. 2.Set the filter on a solid level surface.Allow a minimum clearance above the body for cartridge removal 01 12" (3o5mm)for the CiooS and allow 15" (381mm)for the Ci5o5 and allow i8" (457mm)for the C2ooS.Observe minimum side clearance requirements for the filter,and pump(see fiS.3). Locate drain,air relief and pressure gauge for convenient operation and viewing. 3. Position the filter to allow for proper drainage. 4.If practical,place pump and filter in the shade to shield it from direct heat from the sun. FILTER LOCATION- FILTER LOCATION PRESSURE GAUGE BELOW WATER LINE PRESSURE ( ABOVE WATER LINE p GAUGE LOOMING LOCK RING I _ RETURN TO POOL r RETURN 70�� POOL �i 0 HAYWARD' 8.A 11/2" NPT filter drain plug is furnished with each filter. When making threaded connections to the filter use plastic adapters.Apply three turns of PTFE tape(or use special plastic pipe sealant) to male threads. Screw the fitting into the thread hand tight; REQUIRED CLEARANCE then using a strap wrench,tighten one more full turn.Additional SIDE ABOVE tightening is unnecessary and could result in broken or damaged valve body. IN CM IN CM 9.A manual air relief valve is furnished to aid in bleeding off unwanted CiooS 12 30 12 30 air when starting the filter. 10.All electrical connections should be made in accordance with local C15o5 12 30 15 38 codes. C2005 12 30 18 45 11.Check for joint leaks before operating. Fig 3 12. Refer to pump instruction booklet for pump information. FILTER MOUNTING Secure filter to level concrete slab or other rigid surface to meet all local and national codes. Use fasteners appropriate for the material of the surface being fastened to. Use 2 of the 4 available mounting holes(see fig.i) on opposite corners of the filter base to ensure the filter is secure and level. A CAUTION: Be careful not to over tighten the fasteners when mounting the filter. Failure to do so may cause the base of the filter to crack at the mounting locations causing the filter to be unstable. STARTING THE FILTER Be sure filter drain is closed. Open manual air relief valve and open the suction and return valves (when used). A CAUTION: All suction and discharge valves must be open when starting the system. Failure to do so could cause severe personal injury and/or property damage. Be sure lock ring is locked and in latched position. Stand clear of the filter. Prime and start the pump,following the manufacturer's instructions.Air trapped in the system will automatically vent to the pool and out the manual air relief valve. Close the air relief valve when a steady stream of water (not air or air and water) is being discharged. FILTERING Filtration starts as soon as flow is steady through the filter.As the filter cartridge removes dirt from the pool water, the accumulated dirt causes a resistance to flow.As a result,the gauge pressure will increase and flow will decrease.When the indicated pressure increases 7 to io psi (0.49 to 0.70 Bar) above the starting pressure,or when flow decreases below the desired filtration rate,clean or replace the filter cartridge. CLEAN / REPLACE CARTRIDGE REMOVING CARTRIDGE ELEMENT 1. Shut off the pump. 2. If filter is located below water level,close valves or block off suction & discharge lines to prevent backflow of water from the pool. 3. Remove drain plug and open the manual air relief valve to allow water to drain from filter. 4. Depress safety latch and unscrew the lock ring(counterclockwise direction).Carefully lift off filter head with the attached lock ring to gain access to filter cartridge. (Set Head on a flat surface on top of the handle) 5. Lift out cartridge and clean or,replace with a clean, spare cartridge. (See Cleaning Cartridge.) 6. Clean body o-ring in filter head. REINSTALLING CARTRIDGE ELEMENT 1. Clean any collected debris from the bottom of filter body. Clean the Body o-ring seal area. 2. Carefully replace cartridge element into filter body ensuring that the cartridge sits evenly on the collector hub in bottom of filter body. 3. Place filter head on filter body(being sure filter head o-ring is in place and clean). 4.Tighten lock ring(in clockwise direction) until safety latch fully engages the catch. 5. Proceed as in STARTING THE FILTER. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 5 HAYWARD, CLEANING CARTRIDGE The cartridge filter element can be cleaned by washing inside and out with a garden hose. (The cartridge is easier to clean when dry.)After hosing the cartridge,for best results, allow cartridge to dry and carefully brush pleated surface areas to remove fine particles. Do not pressure wash,as it can damage the filter element. To remove materials such as suntan and body oils from the cartridge pleats,soak the element in a solution of filter element cleaner(various brands available at pool dealer). Follow manufacturer's directions for use and allow an hour for soaking. Hose thoroughly before reinstalling in filter. A CAUTION: Be sure to use a plastic container and take extreme care when handling cleaning agents as they can be harmful to eyes, skin and clothing. After cleaning flush with water. NON-CHLORINE POOLS Cartridges used in pools or spas that use Baquacil® Sanitizer or other similar non-chlorine based products must be cleaned more frequently than when used in pools that utilize a chlorine system. Consult manufacturer's instructions for frequency, instructions,and chemicals required for cleaning elements in these types of systems. Baquacil® is not compatible with chlorine, bromine,any copper based chemical or non-chlorine shock. A spare cartridge filter element is an excellent investment. It provides convenience and ensures that your filter will always be ready to operate at peak efficiency. VACUUMING Vacuuming can be performed directly into the filterwhenever needed.Clean cartridge after vacuuming, if required. WINTERIZING (Filter) In areas where sub-freezing temperatures can be expected,the filter should be drained and/or removed from it's operating location and stored indoors. Remove and clean cartridge. Reinstall cartridge in filter tank. Fully tighten lock ring when storing. SERVICE AND REPAIRS Consult your local authorized Hayward dealer or service center. No returns may be made directly to the factory without the expressed written authorization of Hayward Pool Products. SwimClear Head Loss --^C200S 4.50 _ MODEL EFFECTIVE DESIGN FLOW RATE DESIGN FLOW RATE 4.00 FILTRATION AREA RESIDENTIAL PUBLIC 3.50 FP M' GPM LPM GPM LPM 3.00 CiooS ioo 10.8 ioo 410 37.5 150 2.50 - C15oS 150 13.9 120 454 56 212 2.00 C200S zoo 18.6 120 454 75 284 1.50 MAXIMUM WORKING PRESSURE FOR ALL MODELS 5o PSI(3.45 BAR) 1.00 HIM Lobs(Feet end) 0.00 0 20 40 60 80 100 120 140 Flow in GPM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 6 wti tir • :. fi- • — Y1{�. ... ' �_. , Si, I Cl - L __•. • f r e'. . • =i , •••-. :.A `u'. 1j. f•r, •! . � it, • • • • t et:r: " ' • 2 •71 4 4 r. r Eiy• IlaNNINIXT V ; , - , ,,., ,....„.,,,,,,,..„......„.„..,...,,,,...tvz 0 HAYWARD' PARTS Models CiooS, Ci5oS and C2ooS 3 REF PARTNO. NO. I ��' /�gt * 4 NO. DESCRIPTION REQ'D. 2 f �\ I ECX271261 Pressure Gauge 1 a l / 5 Threaded Adapter for Pressure ���a; �/ 2 CCX1000L 1 4 `'.�l� Gauge 3 CXRLV1oo1 Air Relief Assembly with 0-Ring 1 5 11',' 1 b b 4 CXGAR1oo1Pak2 0-Ring for Gauge Adapter and Air I I c Relief Assembly(set of 2) , i 5 CCX1000N Adapter Nut(set of 2) 2 \�AI ��� 6a CXiooB Filter Head Assembly C1ooS 1 6b CX15oB Filter Head Assembly C15oS 1 kil 6c CX2ooB Filter Head Assembly CzooS 1 7 CXLRL1oo1 Latch for Lock Ring 1 8 CXFHR1oo1 0-Ring for Filter Head 1 8 �IIIIii I I1f III 9a CX1ooXRE Cartridge Element C1ooS 1 . 1Ij 9b CX15oXRE Cartridge Element C1oS 1I IIIIII -. 9c CX2ooXRE Cartridge Element CzooS 1 b IlIu 11111 0 11 10 CXFBA1oo1 Filter Body Assembly 1 b 11a CXFDAioo Filter Diffuser Assembly C1ooS 1 1IF ti c 11b CXFDA15o Filter Diffuser Assembly C15oS 1 luil 11c CXFDA2oo Filter Diffuser Assembly C2ooS 1 lIp11'11111I 12 SP1o22CBLK Drain Plug with 0-Ring 1 ��1►_ 13 SPX3zooUNKIT Union Connection Kit(2 each of 1 Nuts,Connectors,and Gaskets) 10 T p... /i OPTIONAL Blue Value 3 oz.Cartridge \ , ;� CXiooXREBVS I 1 Element C1oo5 01`� � ,�`� ' CX15oXREBVS Blue Value 3 oz.Cartridge 1 • ,:�� v Element C15oS Blue Value 3 oz.Cartridge \`'o 1 CX2ooXREBVS I Element CzooS 12 _____4/ ' SPX15oo1S Union Connector 1.5"Socket 1 SPX15oo1T Union Connector 1.5"NPTF 1 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 7 HAYWARD PRODUCT REGISTRATION DATE OF INSTALLATION (Retain For Your Records) A Retain this Warranty Certificate in a safe and convenient location for your records 90 DAY EXTENDED WARRANTY* REGISTER WITH YOUR SMARTPHONE PROTECT YOUR INVESTMENT IN 2 EASY STEPS 1. TAKE A PHOTO 2. SEND IT IN Take a photo of the camera icon Send it in using one of the methods below Q SMARTPHONE n Text a photo of the camera icon to 71403 OR [ 1 ONLINE MP Visit Hayward.com/Warranty Q— HAY-IEE4INTB —O OR f MESSENGER Send photo to photoregister 'Extended warranty is in addition to applicable product warranty and is for parts only,labor not included. Need help?Visit photoregister.com/help or text HELP to 71403. Hayward and SwimClear are registered trademarks of © Hayward Industries,Inc. ©2020 Hayward Industries,Inc. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 8