Loading...
253 SEMINOLE RD RESA23-0036 revision 2-20-24Revision Request/Correction to Comments ALL INFORMATION s HIGHLIGHTED IN s City of Atlantic Beach Building Department GRAY IS REQUIRED. y 800 Seminole Rd, Atlantic Beach, FL 32233 r jV`j RES/9 .23-06362904) 247-5826 Email: Building-Dept@coab.us PERMIT#: SA .23-063 dRevision to Issued Permit OR E Corrections to Comments Date z 0—.2 LI Project Address: -2_S 3 Seth; 116 I e 14 4+ 1 - )3 c.>i.• 32-a-3 --3 Contractor/Contact Name: Z 4N G ,< C. A P.,5 -O'\ 0 4 Pre 1 I Ji01/1-(-+k Contact Phone: ]3c-Of 1A) Email: 1)c crt k 9I31 @ 6eIIsou-4h. At+ 0.4re e.I\ 5 cis- q o) Description of Proposed Revision/Corrections: Eo 0-k f r re t..)%5'I u v\ 04ftr t) c.,,,x:4-k affirm the revision/correction to comments is inclusive of the proposed changes. Printed name) Wiproposed revision/corrections add additional square footage to original submittal? No Yes(additional s.f.to be added: Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes(additional increase in building valu $ Contractor must sign if increase in valuation) Signature of Contractor/Agent: / li`1 74e- Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments Department Review Required: Building Planning&Zoning Reviewed By Tree Administrator Public Works Public Utilities Public Safety Date Fire Services Updated 10/17/18 Lic: ca.. SOI February 15th, 2024 TO: Atlantic Beach Zoning & Development 800 Seminole Rd Atlantic Beach, FI, 32233 RE: Project: Sears Residence PE/PC: Kyle Mcdonough/William Brown Addendum No.: I Response No.: I The intent of letter is to address a footer concern due to a grade change during an inspection. The mono-lithic footer will need to have an increased amount of rebar to help with the casting and structural integrity that is needed. Please perform footer per detail below: H 4"CONCRETE SLAB zs MINI It NOINTO SLAB O K OOK( C. I Ocr, iii . CONT.O C .OF VERTICALSONLY INSTALL IF FOOTING EXCEEDS MAX)b'DEPTH AS VERTICALIS) W 11 Ost'OC N m I 12)+B CONT vv- rliri a?MINDAROUND CANNERS 1' O p LITERALS N'OC USE CMNRS FOR ROD SUSPENSION VAININ FOOTERS MONO FOOTING @ GRADE n CHANGE SCALE:NO SCALE BZ This concludes our release of work performed for the discrepancies listed and it is to the best of the Engineer's knowledge, the plans and specifications comply with the applicable minimum building codes and the applicable fire-safety standards as determined by local authority in accordance with 2023 FBC 8th edition 110.8.4.4 and chapter 633, Florida statutes. Please at your earliest convenience notify us if any additional information is required. E . 0,y0/i, This item has been electronically Digitally signed by KyleThanks, CENSF,Lc!i signed and sealed by Kyle S. yt No. 83601 *;McDonough using a Digital McDonough Al B Engineering Signature and date. Printed 7.-W copies of this document are not STATE OF J considered signed and sealed Date: 2024.02.16 15.31 .32 ins FCORIDP '"" . and the signature must be i0 Si F''\''\.\\\\\ verified on anyelectronic copies. _05'00'