2120 Beach Avenue RES24-0047 PERMITOWNER:ADDRESS:CITY:STATE:ZIP: MCMANUS JOHN H 2120 BEACH AVE ATLANTIC BEACH FL 32233-5933 COMPANY:ADDRESS:CITY:STATE:ZIP: PWD ORLANDO 4306 SHADER RD STE100 ORLANDO FL 32808 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169510 0010 SECTION LAND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 2120 BEACH AVE RESIDENTIAL WINDOWS/DOORS ONE DOOR $6147.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $85.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $42.50 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: IN-PROGRESS INSPECTIONS ARE REQUIRED FOR EXTERIOR SIDING, WINDOW, AND DOOR INSPECTIONS, AND SHOULD BE SCHEDULED FOR THE FIRST DAY OF WORK. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/5/2024 PERMIT NUMBER RES24-0047 ISSUED: 3/5/2024 EXPIRES: 9/1/2024 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $131.50 2 of 2Issued Date: 3/5/2024 PERMIT NUMBER RES24-0047 ISSUED: 3/5/2024 EXPIRES: 9/1/2024 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $131.50 RES24-0047 Address: 2120 BEACH AVE APN: 169510 0010 $131.50 BUILDING $85.00 BUILDING PERMIT 455-0000-322-1000 0 $85.00 BUILDING PLAN REVIEW $42.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $42.50 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R26392 $131.50 Printed: Tuesday, March 5, 2024 9:52 AM Date Paid: Tuesday, March 05, 2024 Paid By: PWD ORLANDO Pay Method: CREDIT CARD 10150580448 1 of 1 Cashier: AG Cash Register Receipt City of Atlantic Beach Receipt Number R26392 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: ____________________________________________________ Permit No. ___________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION _____________________________________________________ Permit Type BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL31712-R2 Application Type Revision Code Version 2023 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed anPOC and/or the Commission if necessary. Comments Archived Product Manufacturer Pella Corporation Address/Phone/Email 102 Main St.Pella, IA 50219(641) 621-6096pellaproductapproval@pella.com Authorized Signature Kyle Puntpuntkj@pella.com Technical Representative Joseph Hayden Address/Phone/Email 102 Main StreetPella, IA 50219(641) 621-6096jahayden@pella.com Quality Assurance Representative Pat Bortscheller Address/Phone/Email 102 Main StreetPella, IA 50219(641) 621-1000PJBortscheller@pella.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard)Standard Year ASTM E330 2014 Equivalence of Product StandardsCertified By Product Approval Method Method 1 Option A Date Submitted 01/25/2024 Date Validated 01/26/2024 Date Pending FBC Approval Date Approved 02/03/2024 Summary of Products FL #Model, Number or Name Description 31712.1 Pella Entry Doors 6'-8" Glazed I/S or O/S Single or Double Door w/ Sidelights, standard latch and deadbolt Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Configurations of glass shall conform to current ASTME1300 and have safety rated glass. Not approved for use wherewater infiltration resistance is required by the door. Unless unitsare installed in a non-habitable area where the unit & the area aredesigned to accept water infiltration, units shall be installed onlyat locations protected by a canopy or overhang where-by theoverhang (OH) ratio is equal to or more than 1.0 per FBC. 12'-0"x 6'-8" max nominal size. Certification Agency Certificate FL31712_R2_C_CAC_NI014620.02-R1.pdf FL31712_R2_C_CAC_NI014620.03-R1.pdfQuality Assurance Contract Expiration Date 05/31/2025Installation Instructions FL31712_R2_II_Addendum to NI014620.02 NI01000063669.pdf Verified By: National Accreditation & Management Created by Independent Third Party: Evaluation Reports FL31712_R2_AE_514600-1A.pdf FL31712_R2_AE_514602-1A.pdf Created by Independent Third Party: Yes 31712.2 Pella Entry Doors 6'-8" Glazed I/S or O/S Single or Double Door w/ Sidelights, multi-point lock Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Configurations of glass shall conform to current ASTME1300 and have safety rated glass. Not approved for use wherewater infiltration resistance is required by the door. Unless unitsare installed in a non-habitable area where the unit & the area aredesigned to accept water infiltration, units shall be installed onlyat locations protected by a canopy or overhang where-by theoverhang (OH) ratio is equal to or more than 1.0 per FBC. 12'-0"x 6'-8" max nominal size. Certification Agency Certificate FL31712_R2_C_CAC_NI014620.02-R1.pdf FL31712_R2_C_CAC_NI014620.03-R1.pdfQuality Assurance Contract Expiration Date 05/31/2025Installation Instructions FL31712_R2_II_Addendum to NI014620.02 NI01000063674.pdf Verified By: National Accreditation & Management Created by Independent Third Party: Evaluation Reports FL31712_R2_AE_514600-1A.pdf FL31712_R2_AE_514602-1A.pdf Created by Independent Third Party: Yes 31712.3 Pella Entry Doors 6'-8" Flush Glazed I/S or O/S Single or Double DoSidelights, standard latch and deadbolt Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to current ASTME1300 and have safety rated glass. Not approved for use wherewater infiltration resistance is required by the door. Unless unitsare installed in a non-habitable area where the unit & the area aredesigned to accept water infiltration, units shall be installed onlyat locations protected by a canopy or overhang where-by theoverhang (OH) ratio is equal to or more than 1.0 per FBC. 12'-0"x 6'-8" max nominal size. Certification Agency Certificate FL31712_R2_C_CAC_NI014557.01-R1.pdf FL31712_R2_C_CAC_NI014557-R1.pdfQuality Assurance Contract Expiration Date 05/31/2025Installation Instructions FL31712_R2_II_Addendum to NI014557 NI01455000064059.pdf Verified By: National Accreditation & Management Created by Independent Third Party: Evaluation Reports FL31712_R2_AE_514600-1A.pdf FL31712_R2_AE_514602-1A.pdf Created by Independent Third Party: Yes 31712.4 Pella Entry Doors 6'-8" Flush Glazed I/S or O/S Single or Double DoSidelights, multi-point lock Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to current ASTME1300 and have safety rated glass. Not approved for use wherewater infiltration resistance is required by the door. Unless units Certification Agency Certificate FL31712_R2_C_CAC_NI014557.01-R1.pdf FL31712_R2_C_CAC_NI014557-R1.pdfQuality Assurance Contract Expiration Date 05/31/2025Installation Instructions FL31712_R2_II_Addendum to NI014557 NI01455000064087.pdf are installed in a non-habitable area where the unit & the area are designed to accept water infiltration, units shall be installed onlyat locations protected by a canopy or overhang where-by the overhang (OH) ratio is equal to or more than 1.0 per FBC. 12'-0"x 6'-8" max nominal size. Verified By: National Accreditation & Management Created by Independent Third Party: Evaluation Reports FL31712_R2_AE_514600-1A.pdf FL31712_R2_AE_514602-1A.pdf Created by Independent Third Party: Yes 31712.5 Pella Entry Doors 6'-8" Opaque I/S or O/S Single or Double Door w/ Sidelights, standard latch and deadbolt Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to current ASTM E1300 and have safety rated glass. Not approved for use wherewater infiltration resistance is required by the door. Unless units are installed in a non-habitable area where the unit & the area aredesigned to accept water infiltration, units shall be installed only at locations protected by a canopy or overhang where-by theoverhang (OH) ratio is equal to or more than 1.0 per FBC. 12'-0" x 6'-8" max nominal size. Certification Agency Certificate FL31712_R2_C_CAC_NI014620.01-R1.pdf FL31712_R2_C_CAC_NI014620-R1.pdfQuality Assurance Contract Expiration Date 05/31/2025Installation Instructions FL31712_R2_II_Addendum to NI014620 NI01462000064135.pdf Verified By: National Accreditation & Management Created by Independent Third Party: Evaluation Reports FL31712_R2_AE_514600-1A.pdf FL31712_R2_AE_514602-1A.pdf Created by Independent Third Party: Yes 31712.6 Pella Entry Doors 6'-8" Opaque I/S or O/S Single or Double Door w/Sidelights, multi-point lock Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to current ASTME1300 and have safety rated glass. Not approved for use where water infiltration resistance is required by the door. Unless unitsare installed in a non-habitable area where the unit & the area are designed to accept water infiltration, units shall be installed onlyat locations protected by a canopy or overhang where-by the overhang (OH) ratio is equal to or more than 1.0 per FBC. 12'-0"x 6'-8" max nominal size. Certification Agency Certificate FL31712_R2_C_CAC_NI014620.01-R1.pdf FL31712_R2_C_CAC_NI014620-R1.pdf Quality Assurance Contract Expiration Date 05/31/2025 Installation Instructions FL31712_R2_II_Addendum to NI014620 NI01462 000064138.pdf Verified By: National Accreditation & Management Created by Independent Third Party: Evaluation Reports FL31712_R2_AE_514600-1A.pdf FL31712_R2_AE_514602-1A.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Re Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records req electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487. Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wi if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record to supply a personal address, please provide the Department with an email address which can be made available to the public. To determ licensee under Chapter 455, F.S., please click here . Product Approval Accepts: CERTIFICATION NO: NI014620.02-R1 DATE: 01/08/2020 CERTIFICATION PROGRAM: Structural COMPANY: Pella CODE: 1735-1 REVISION DATE: 12/16/2020 To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Pella Corporation Series “Pella Entry Doors” 102 Main Street Glazed Fiberglass In-Swing Door Pella, IA 50219 w/Sidelites & Composite Frame Configuration: OXXO Glazing: Insulating Glass (Tempered) Frame: W-3785mm(149") H-2074mm(81.63") Panel: W-908mm(35.75") H-2006mm(79") DLO: W-533mm(21") H-1600mm(63") SPECIFICATION PRODUCT RATING ASTM E330-02/14 Design Pressure: +40/-40 psf Product Tested By: American Test Lab, Inc. Report No: ATLNC 0829.01-16/ATLNC 1013.01-16/W-1977 Expiration Date:May 31, 2025 Administrator’s Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 NOTICE OF PRODUCT CERTIFICATION COMPONENT QUALITY INFORMATION:REFER TO DOCUMENT PDS688 AND PELLA SUPPLIER QUALITY MANUALFOR APPLICATION AND DEFINITION OF THESE SYMBOLS. [C] INDICATES CRITICAL DIMENSIONS [K] INDICATES KEY DIMENSIONSC42715TOLERANCES UNLESSOTHERWISE NOTED.X = ±.XX = ±.XXX = ±ANGLES = ±UNITS ARE IN INCHESCLASS:ECO:2/18/2020CONFIDENTIAL PROPERTY OF PELLA CORPORATION. DO NOT DUPLICATE OR TRANSMIT WITHOUT THE EXPRESSWRITTEN PERMISSION OF PELLA CORPORATION. DO NOT SCALE. DRAWING BASED ON ASME Y14.5M-1994PELLA CORPORATION102 MAIN STREET, PELLA, IOWA 50219DRAWING NUMBER1 of 4DES-000063669PAGEREV1ENGR.:DRAWN:DATE CREATED:DES-000063669.DFTFILE NAME:DRW - ASSEMBLY - UNITH.ANDERSONJ.HOUSERCERTIFICATION,,,,F-PASS, 6'8" NON-IMPACT, GLAZED PANEL DB LOCKX.XX.XXX.XXXX.X°REVCHGSHTREVISIONSCODWNENGDATE1A2CORRECT MAX FRAME HEIGHT; 81.875 TO 81.625. CORRECT MAX PANEL HEIGHT;79.250 TO 79.000.C45068J.HOUSERJ.MCANINCH12/30/2020Certification No: NI014620.02/NI014620.03Reviewed by: TDWDate Reviewed: 12/30/2020 C42715TOLERANCES UNLESSOTHERWISE NOTED.X = ±.XX = ±.XXX = ±ANGLES = ±UNITS ARE IN INCHESCLASS:ECO:2/18/2020CONFIDENTIAL PROPERTY OF PELLA CORPORATION. DO NOT DUPLICATE OR TRANSMIT WITHOUT THE EXPRESSWRITTEN PERMISSION OF PELLA CORPORATION. DO NOT SCALE. DRAWING BASED ON ASME Y14.5M-1994PELLA CORPORATION102 MAIN STREET, PELLA, IOWA 50219DRAWING NUMBER2 of 4DES-000063669PAGEREV1ENGR.:DRAWN:DATE CREATED:DES-000063669.DFTFILE NAME:DRW - ASSEMBLY - UNITH.ANDERSONJ.HOUSERCERTIFICATION,,,,F-PASS, 6'8" NON-IMPACT, GLAZED PANEL DB LOCKSHEET #321 TYPICAL ELEVATIONS & GENERAL NOTESANCHORING LOCATIONS & DETAILSTABLE OF CONTENTSDESCRIPTION6'-8" DOUBLE DOOR WITH / WITHOUT SIDELITESFIBERGLASS GLAZED DOOR UNITANCHORING LOCATIONS & DETAILSXCONFIGXXOX or XOOXOOXXOMAX WIDTH37.5"74"75"112.5"149"INSWING OUTSWINGDESIGN PRESSURE RATINGEVALUATED FOR USE IN LOCATIONS ADHERING TOTHE FLORIDA BUILDING CODE, EXCLUDING THE HIGHREQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUMDESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES,DOES NOT EXCEED THE DESIGN PRESSURES LISTED.1.GENERAL NOTESWHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION,HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED.2.VELOCITY HURRICANE ZONE AND WHERE PRESSURE+40.0 / -40.0 +40.0 / -40.0+40.0 / -40.0 +40.0 / -40.0+40.0 / -40.0 +40.0 / -40.0+40.0 / -40.0 +40.0 / -40.0+40.0 / -40.0 +40.0 / -40.0DOUBLE DOOR UNIT W/SIDELITES37.5" MAX.FRAME WIDTHMAX. FRAME HEIGHT 81.625"149" MAX. OVERALL FRAME WIDTH36.375" MAX.PANEL WIDTHW/ASTRAGALMAX. PANEL HEIGHT 79"D.L.O.21" MAXDOUBLE DOOR UNIT W/SIDELITESSINGLE DOOR UNIT W/SIDELITESSINGLE DOOR UNITSINGLE DOOR UNITSINGLE DOOR UNITDOUBLE DOOR UNITWITH SIDELITEWITH SIDELITE63" MAX D.L.O.X.XX.XXX.XXXX.X°Certification No: NI014620.02/NI014620.03Reviewed by: TDWDate Reviewed: 12/30/2020 C42715TOLERANCES UNLESSOTHERWISE NOTED.X = ±.XX = ±.XXX = ±ANGLES = ±UNITS ARE IN INCHESCLASS:ECO:2/18/2020CONFIDENTIAL PROPERTY OF PELLA CORPORATION. DO NOT DUPLICATE OR TRANSMIT WITHOUT THE EXPRESSWRITTEN PERMISSION OF PELLA CORPORATION. DO NOT SCALE. DRAWING BASED ON ASME Y14.5M-1994PELLA CORPORATION102 MAIN STREET, PELLA, IOWA 50219DRAWING NUMBER3 of 4DES-000063669PAGEREV1ENGR.:DRAWN:DATE CREATED:DES-000063669.DFTFILE NAME:DRW - ASSEMBLY - UNITH.ANDERSONJ.HOUSERCERTIFICATION,,,,F-PASS, 6'8" NON-IMPACT, GLAZED PANEL DB LOCKDETAIL "F" ASTRAGALSTRIKE PLATE TO FRAMEATTACH ASTRAGAL RETAINER BOLTDETAIL "E" ASTRAGALAS SHOWN.#8 x 2"DETAIL "C"DETAIL "D"#8 x 2"#8 x 2"#10 x 5/8"#10 x 5/8"#10 x 1"#10 x 1"GGHHSEE DETAIL"C"SEE DETAIL"D"4 MORE EQUALLY SPACED6"6"6"41.250"6"6"5.5"6"7.375"31"31"ALCCLBAABBLCLC3"6"3"6"7.375"31"31"3"6"3"6"3"3"6"3"6"3"6"3"SEE DETAIL"C"SEE DETAIL"F"3"6"SEE DETAIL"E"6"6"3"3"6"3"6"3"3"3"6"4 MORE EQUALLY SPACED6"LCCLLCLC#10 x 2-1/2"#10 x 5/8"INSWING THRESHOLD1.375"LCCLZ-SERIES O/S THRESHOLD1.482"INTERIOREXTERIORTYPICAL GLAZING DETAIL#6 X 1-1/2" PHSHOT MELTNON-IMPACT GLASSELASTOMERHOT MELTELASTOMER1/2" BITE.0124" TEMP.BUTYL, FOAM, OR METAL SPACER1" OR 1/2" INSULATED GLASSDECORATIVE INSERT(OPTIONAL)ASTRAGAL RETAINER BOLT HOLEMUST BE DRILLED THROUGHTHE THRESHOLD & INTO THESTRUCTURE DEEP ENOUGHFOR A 1.375" THROWX.XX.XXX.XXXX.X°Certification No: NI014620.02/NI014620.03Reviewed by: TDWDate Reviewed: 12/30/2020 C42715TOLERANCES UNLESSOTHERWISE NOTED.X = ±.XX = ±.XXX = ±ANGLES = ±UNITS ARE IN INCHESCLASS:ECO:2/18/2020CONFIDENTIAL PROPERTY OF PELLA CORPORATION. DO NOT DUPLICATE OR TRANSMIT WITHOUT THE EXPRESSWRITTEN PERMISSION OF PELLA CORPORATION. DO NOT SCALE. DRAWING BASED ON ASME Y14.5M-1994PELLA CORPORATION102 MAIN STREET, PELLA, IOWA 50219DRAWING NUMBER4 of 4DES-000063669PAGEREV1ENGR.:DRAWN:DATE CREATED:DES-000063669.DFTFILE NAME:DRW - ASSEMBLY - UNITH.ANDERSONJ.HOUSERCERTIFICATION,,,,F-PASS, 6'8" NON-IMPACT, GLAZED PANEL DB LOCKALCLCAAGLCLCGBHB31"31"7.375"SEE DETAIL"C" SHT. 24 MORE EQUALLY SPACED41.250"4 MORE EQUALLY SPACED6"3"3"6"6"SEE DETAIL"F" SHT. 26"6"6"3"6"3"3"6"3"6"6"6"6"6"3"3"6"SEE DETAIL"E" SHT. 26"6"SEE DETAIL"D" SHT. 25.5"3"3"6"3"3"6"6"6"LCLCLCLCLCLCTHE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROMANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENTOF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVEWOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TOTRANSFER LOADS TO STRUCTURE.3.4.MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS.5.ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED,FASTENER RATING FROM THE DIFFERENT FASTENERSBEING CONSIDERED FOR USE. JAMB, HEAD, ANDTHRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE#10 WOOD SCREWS, 1/4" TAPCONS, AND #10 TEK SCREWS.A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACHANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2".1.ATTACHMENT DETAILSIGNED AND SEALED BY ROBERTO LOMAS, PE(FLORIDA #62514) WITH THE LOWEST (LEAST)MINIMUM EMBEDMENT OF 1-1/4".TYPICAL WOOD BUCKANCHOR INSTALLATIONCL1.50"MIN0.25"MAXSHIMCL1.25"MIN0.25"MAXSHIMTYPICAL MASONRYANCHOR INSTALLATIONWOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGEINTEGRAL WWMULLION (CHS)(4) #10X2-1/2"WOOD SCREWSEACH ENDCL1.25"MIN0.25"MAXSHIM1X BUCK MASONRYANCHOR INSTALLATIONANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TOACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE.2.DISTANCE MIN 1/2".PELLA ESSENTIALS GRADE 3 CYLINDRICAL LATCH AND GRADE 1CYLINDRICAL DEADBOLT TO BE INSTALLED AT 5-1/2" C/L.1.HARDWARE SCHEDULE4" X 4" FULL MORTISE BUTT HINGES.2.BALDWIN RESERVE CYLINDRICAL LATCH AND BALDWIN RESERVE1a.CYLINDRICAL DEADBOLT TO BE INSTALLED AT 5-1/2" C/L.X.XX.XXX.XXXX.X°Certification No: NI014620.02/NI014620.03Reviewed by: TDWDate Reviewed: 12/30/2020