Loading...
208 POINSETTIA ST ROOF24-0011 COAB Permit Form with Conditions PERMITOWNER:ADDRESS:CITY:STATE:ZIP: CARTER DAWN 208 POINSETTIA ST ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: Covenant Roofing & Construction 4590 CR 218 Middleburg FL 32068 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170574 0010 SALTAIR SEC 03 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 208 POINSETTIA ST ROOF NON SHINGLE SHINGLE AND MODIFIED ROOF $7950.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING NOTICE OF COMMENCEMENT INFORMATIONAL Notes: No inspections may be scheduled until a copy a recorded Notice of Commencement has been submitted to the Building Department NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/5/2024 PERMIT NUMBER ROOF24-0011 ISSUED: 3/5/2024 EXPIRES: 9/1/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $90.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.03 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $139.03 2 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In- Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 2 of 2Issued Date: 3/5/2024 PERMIT NUMBER ROOF24-0011 ISSUED: 3/5/2024 EXPIRES: 9/1/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ROOF24-0011 1/2/24, 11:18 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3Baek%2f8szk0iJtPtapKmxTQg%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL10124-R35 Application Type Revision Code Version 2023 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus DriveParisppany, NJ 07054(800) 766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen lreith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054(800) 766-3411TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/16/2025 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10124_R35_COI_2023_07_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2017 ASTM D3161 2016 ASTM D3462 2016 ASTM D7158 2019 TAS 100 2023 TAS 107 2020 Equivalence of Product StandardsCertified By 1/2/24, 11:18 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3Baek%2f8szk0iJtPtapKmxTQg%3d%3d 2/2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/12/2023 Date Validated 10/19/2023 Date Pending FBC Approval 10/28/2023 Date Approved 12/12/2023 Summary of Products FL #Model, Number or Name Description 10124.1 GAF Asphalt Roof Shingles (HVHZ)Fiberglass reinforced, laminated asphalt shingles for use in FBC HVHZ jurisdictions. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: Refer to PEER-GAF-002.B, Section 5 for Limits of Use. Installation Instructions FL10124_R35_II_2023_10_12_FINAL_PEER-GAF-002.B_SHINGLES_HVHZ_FL10124-R35.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL10124_R35_AE_2023_10_12_FINAL_PEER-GAF-002.B_SHINGLES_HVHZ_FL10124-R35.pdf Created by Independent Third Party: Yes 10124.2 GAF Asphalt Roof Shingles (NON- HVHZ) Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge asphalt shingles for use in FBC non-HVHZ jurisdictions. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to PEER-GAF-002.A, Section 5 for Limits of Use. Installation Instructions FL10124_R35_II_2023_10_12_FINAL_PEER-GAF- 002.A_SHINGLES_NON-HVHZ_FL10124-R35.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: YesEvaluation Reports FL10124_R35_AE_2023_10_12_FINAL_PEER-GAF- 002.A_SHINGLES_NON-HVHZ_FL10124-R35.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronicmail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they haveone. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply apersonal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter455, F.S., please click here . Product Approval Accepts: ® NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT P.E. EVALUATION REPORT (PEER) GAF 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 PEER-GAF-002.B.R1 FL10124-R35 (HVHZ) Date of Issuance: 06/20/2023 Revision 1: 10/12/2023 SCOPE: This P.E. Evaluation Report (henceforth ‘PEER’) is issued under F.A.C. Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 8th Edition (2023) Florida Building Code, High Velocity Hurricane Zone (HVHZ) sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles (HVHZ) LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1523.5.1. CONTINUED COMPLIANCE: This PEER is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our PEERs by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its PEER relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO P.E. Evaluated” may be displayed in advertising literature. If any portion of the PEER is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire PEER shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This PEER consists of pages 1 through 3. Prepared by: CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the PEERs are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this PEER, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC, LLC Digitally signed by Robert Nieminen Date: 2023.10.12 '12:25:13 -04'00 NEMO|etc.® ©NEMO ETC, LLC PEER-GAF-002.B.R1 Certificate of Authorization #32455 P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ FL10124-R35 (HVHZ) GAF Asphalt Roof Shingles Revision 1: 10/12/2023 BACK TO TOP Page 2 of 3 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Product Approval Method: Method 1, Option D – Codified Material, Evaluation by Engineer Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 8th Edition (2023) Florida Building Code, High Velocity Hurricane Zone (HVHZ) through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations of Use set forth herein. 2. STANDARDS: SECTION PROPERTY STANDARD 1523.6.5.1, TAS 110 Material standard ASTM D3462 1523.6.5.1, TAS 110 Wind Driven Rain TAS 100 1523.6.5.1, TAS 110 Wind Resistance TAS 107 3. REFERENCES: ENTITY EXAMINATION REFERENCE DATE Farabaugh ET (TST1654) TAS 100 T174-22 04/11/2022 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4788198026 05/23/2022 UL, LLC. (QUA 9625) Quality Control Service Confirmation 12/06/2022 UL, LLC. (QUA 9625) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: TABLE 1: ASPHALT SHINGLE COMPONENTS PRODUCT DESCRIPTION MATERIAL STANDARD PLANT(S) Timberline® Solar HDZ® fiberglass reinforced, laminated asphalt roof shingles ASTM D3462 IN-MV 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this PEER, or previous versions thereof, is/was used for permitting or design guidance. PEERs are not to be construed as representing any attributes not specifically listed, nor are PEERs to be construed as an endorsement of the subject, or a recommendation for its use. There is no warranty by NEMO ETC, LLC or Robert Nieminen, P.E., express or implied, as to any finding or other matter in this PEER, or as to any product covered by the PEER. 5.2 This PEER is exclusively for use in FBC High Velocity Hurricane Zone jurisdictions, as defined in FBC Chapter 2 (Broward and Miami-Dade Counties). 5.3 This PEER pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This PEER does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2: WIND CLASSIFICATIONS, ASPHALT SHINGLES PRODUCT FBC 1523.6.5.1 MEAN ROOF HEIGHT Timberline® Solar HDZ® TAS 107 Max. 33 ft NEMO|etc.® ©NEMO ETC, LLC PEER-GAF-002.B.R1 Certificate of Authorization #32455 P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ FL10124-R35 (HVHZ) GAF Asphalt Roof Shingles Revision 1: 10/12/2023 BACK TO TOP Page 3 of 3 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this PEER. 6. INSTALLATION: 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment, fasteners, flashings and metal accessories shall comply with Roofing Application Standard RAS 115 and the shingle manufacturer’s minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per F.A.C. Rule 61G20-3, for use in FBC HVHZ jurisdictions, per FBC Sections 1518.7.1 and Roofing Application Standard RAS 115. 6.2 ASPHALT SHINGLES: 6.2.1 Installation of Timberline® Solar HDZ® shall comply with GAF current published instructions, using minimum six (6) nails per shingle in accordance with FBC 1518.7.3.2. 6.2.2 Fasteners shall be in accordance with manufacturer’s published requirements, but not less than Roofing Application Standard RAS 115. Staples are not permitted. 6.2.3 The following depict nail-placement locations for Timberline® Solar HDZ® designed with a ‘target nail zone’. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact GAF for details. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL (QUA9625): (360) 817-5512; bsai.inspections@ul.com - END OF PEER - 1/2/24, 10:59 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtCUGgvjQiz6GuqLSXh%2bJESxGPHob9F1xECmRgY4XqJIg%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL17401-R8 Application Type Revision Code Version 2023 Application Status Approved Comments Archived Product Manufacturer Mid-States Asphalt & Cant Strip, Inc. Address/Phone/Email 1637 51st AveTuscaloosa, AL 35401(205) 394-3078 moises@msaroof.com Authorized Signature Moises Rached moises@msaroof.com Technical Representative Moises Rached Address/Phone/Email 1637 51st Ave Tuscaloosa, AL 35401(205) 469-2101moises@msaroof.com Quality Assurance Representative Moises Rached Address/Phone/Email 1637 51st AveTuscaloosa, AL 35401 (205) 469-2101 moises@msaroof.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed FloridaProfessional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developedthe Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/27/2026 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL17401_R8_COI_CoI_CREEK Technical Services_2023.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D 1970 2017 TAS 103 2020 TAS 110 2000 UL 1897 2015 1/2/24, 10:59 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtCUGgvjQiz6GuqLSXh%2bJESxGPHob9F1xECmRgY4XqJIg%3d%3d 2/2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/05/2023 Date Validated 10/05/2023 Date Pending FBC Approval 10/09/2023 Date Approved 12/12/2023 Summary of Products FL #Model, Number or Name Description 17401.1 QUIK-Stick Ice & Water Granular,QUIK-Stick Ice & Water Sand, QUIK- Stick HT Smooth, QUIK-Stick HT Pro, QUIK-Stick FS Self-Adhered Underlayments Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-52.5 Other: Refer to Evaluation Report for Limitations of Use.Wind uplift applicable to QUIK-Stick HT only. Installation Instructions FL17401_R8_II_MSA17001.5 2023 FBC Eval QUIK-Stickfinal.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL17401_R8_AE_MSA17001.5 2023 FBC Eval QUIK-Stickfinal.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronicmail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they haveone. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply apersonal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter455, F.S., please click here . Product Approval Accepts: CREEK Technical Services, LLC MSA17001.5 FL17401-R8 Page 1 of 4 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Registry No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 VALUATION REPORT FLORIDA BUILDING CODE, 8TH EDITION (2023) Manufacturer: MID-STATES ASPHALT AND CANT STRIP, INC. Issued October 5, 2023 1637 51st Street Tuscaloosa, AL 35401 (800) 489-2391 www.msaroof.com Manufacturing Location: Tuscaloosa, AL Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Edition: Florida Building Code, 8th Edition (2023) including High-Velocity Hurricane Zones (HVHZ) Code Sections: 1504.2.1.4, 1504.3.1, 1507.1.1, 1518.2, 1523.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2015 PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2017a PRI Construction Materials Technologies (TST6049) MSA-047-02-01 ASTM D 1970 2017a PRI Construction Materials Technologies (TST6049) MSA-048-02-01 ASTM D 1970 2017a PRI Construction Materials Technologies (TST6049) MSA-054-02-01.1 TAS 103 TAS 110 2020 2000 PRI Construction Materials Technologies (TST6049) MSA-056-02-01 ASTM D 1970 2017a PRI Construction Materials Technologies (TST6049) MSA-057-02-01 ASTM D 1970 2017a PRI Construction Materials Technologies (TST6049) MSA-060-02-01 ASTM D 1970 2017a PRI Construction Materials Technologies (TST6049) MSA-060-02-02 TAS 110 2000 PRI Construction Materials Technologies (TST6049) MSA-062-02-01 ASTM D 1623 2017 PRI Construction Materials Technologies (TST6049) 1085T0002 TAS 110 2000 PRI Construction Materials Technologies (TST6049) 1085T0007 ASTM D 1623 2017 PRI Construction Materials Technologies (TST6049) 1085T0011 ASTM D 1623 TAS 103 2017 2020 PRI Construction Materials Technologies (TST6049) 1085T0015 ASTM D 1623 TAS 103 2017 2020 PRI Construction Materials Technologies (TST6049) 1085T0019 ASTM D 1970 TAS 110 2017a 2000 PRI Construction Materials Technologies (TST6049) 1085T0046 TAS 110 TAS 103 2000 2020 PRI Construction Materials Technologies (TST6049) 1085T0047 ASTM D 1970 TAS 110 2017a 2000 A CREEK Technical Services, LLC MSA17001.5 FL17401-R8 Page 2 of 4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MID-STATES ASPHALT AND CANT STRIP, INC Self-Adhering Underlayments PRODUCT DESCRIPTION AND LIMITS OF USE QUIK-Stick Ice & Water Granular QUIK-Stick Ice & Water Granular is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 50 mils. QUIK-Stick Ice & Water Granular is permitted to be used as prescribed in FBC Sections 1507.1.1 and 1518.2 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick Ice & Water Sand QUIK-Stick Ice & Water Sand is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and surfaced with sand. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 50 mils. QUIK-Stick Ice & Water Sand is permitted to be used as prescribed in FBC Sections 1507.1.1 and 1518.2 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick HT Smooth QUIK-Stick HT Smooth is an ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Seventh Edition compliant self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and woven poly-fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft or 3-ft 3-in x 61-ft and has a nominal thickness of 60 mils. QUIK-Stick HT Smooth (Woven Facer) is to be used as prescribed in FBC Sections 1507.1.1 and 1518.2. QUIK-Stick HT is permitted to be used with mechanically attached or adhered clay or concrete tile roofing using either ICP Polyset AH-160, DAP Touch ’n Seal® Storm Bond Roof Tile Adhesive or DuPont™ TILE BOND™ Roof Tile Adhesive. Exposure on the roof deck shall be limited to a maximum 180 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. QUIK-Stick HT Pro QUIK-Stick HT Pro is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and textured film surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 60 mils. QUIK-Stick HT Pro is permitted to be used as prescribed in FBC Sections 1507.1.1 and 1518.2 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 120 days. QUIK-Stick FS QUIK-Stick FS is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and textured film surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 45 mils. QUIK-Stick FS is permitted to be used as prescribed in FBC Sections 1507.1.1 and 1518.2 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. A CREEK Technical Services, LLC MSA17001.5 FL17401-R8 Page 3 of 4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MID-STATES ASPHALT AND CANT STRIP, INC Self-Adhering Underlayments PRODUCT APPLICATION Min. Roof Slope: 2:12 or in accordance in with the FBC Application: All underlayments shall be installed in accordance with the FBC and the manufacturer’s installation requirements. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3” side laps and minimum 6” end laps staggered min. 6-ft.from preceding course. It is permissible to back nail the underlayment 12-inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Min. Application Temperature: 40°F; Contact the manufacturer when installing at temperatures below the minimum application temperature. WIND RESISTANCE The Allowable Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Sections 1504.9 and 1523.4. Underlayment System No.1 – QUIK-Stick HT Smooth only Roof Deck: Min. 15/32-inch, 32/16 span rated, CDX plywood attached to wood supports spaced a maximum 24” o.c. Underlayment: QUIK-Stick HT Smooth shall be fully self-adhered to the optionally primed plywood deck in accordance with manufacturer’s installation instructions. Allowable Design Pressure: -52.5 psf A CREEK Technical Services, LLC MSA17001.5 FL17401-R8 Page 4 of 4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MID-STATES ASPHALT AND CANT STRIP, INC Self-Adhering Underlayments GENERAL LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 3) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 4) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 5) All side lap seams shall be installed to shed water from the deck. 6) The underlayment may be used as described in other current FBC product approval documents. 7) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 8) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 9) Allowable Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 8th Edition (2023) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT This item has been digitally signed and sealed by Zachary R. Priest, PE, on 10/5/2023. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 2023.10.05 12:33:53 -04'00' 1/2/24, 10:41 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvweIwRFXRvHOHSbalV%2f8EtONcQHuTw%2bc%2fZCOBPT3%2fIVA%3d…1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL2533-R30 Application Type Revision Code Version 2023 Application Status Approved Comments Archived Product Manufacturer CertainTeed, LLC (Roofing) Address/Phone/Email 20 Moores RoadMalvern, PA 19355(610) 893-5945 Alex.T.James@saint-gobain.com Authorized Signature Alex James Alex.T.James@saint-gobain.com Technical Representative Chad Johnson Address/Phone/Email 20 Moores Road Malvern, PA 19355(262) 444-8720Chad.Johnson@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/08/2025 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL2533_R30_COI_2023_07_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2017 ASTM D2178 2015 ASTM D41 2016 ASTM D4601 2012 ASTM D4897 2016 ASTM D6163 2016 ASTM D6164 2016 ASTM D6222 2016 ASTM D6509 2016 1/2/24, 10:41 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvweIwRFXRvHOHSbalV%2f8EtONcQHuTw%2bc%2fZCOBPT3%2fIVA%3d…2/2 ASTM G155 2013 FM 4470 2016 FM 4474 2011 TAS 114 2011 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/04/2023 Date Validated 08/08/2023 Date Pending FBC Approval 08/10/2023 Date Approved 10/17/2023 Date Revised 12/13/2023 Summary of Products FL #Model, Number or Name Description 2533.1 Flintlastic Modified Bitumen Roof Systems (HVHZ) Modified bitumen roof systems for use in FBC HVHZ jurisdictions. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: +N/A/-635 Other: 1.) Refer to PEER Section 5 for Limits of Use. 2.) The design pressure noted in this application relates to one specific system. Refer to the PEER Appendix for all systems and max design pressures. Installation Instructions FL2533_R30_II_2023_08_03_FINAL_A1_PEER-CTR- 003.B_HVHZ_FL2533-R30.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: YesEvaluation Reports FL2533_R30_AE_2023_08_03_FINAL_PEER-CTR- 003.B_HVHZ_FL2533-R30.pdf Created by Independent Third Party: Yes 2533.2 Flintlastic Modified Bitumen RoofSystems (NON-HVHZ)Modified bitumen roof systems for use in FBC non-HVHZjurisdictions. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-635 Other: 1.) Refer to PEER Section 5 for Limits of Use. 2.) The design pressure noted in this application relates to one specific system. Refer to the PEER Appendix for all systemsand max design pressures. Installation Instructions FL2533_R30_II_2023_08_03_FINAL_A1_PEER-CTR- 003.A_NON-HVHZ_FL2533-R30.pdf Verified By: Robert Nieminen, PE PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2533_R30_AE_2023_08_03_FINAL_PEER-CTR-003.A_NON- HVHZ_FL2533-R30.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronicmail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they haveone. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply apersonal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter455, F.S., please click here . Product Approval Accepts: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 1 of 74 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6 1B Wood New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7 1C Wood New or Reroof (Tear-Off) B-3 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 8 1D Wood New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 10 1E Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 12 1F Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 14 1G Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 17 1H Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 19 2A Steel or Structural concrete New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 20 2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 24 2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 28 3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 31 3B Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 40 4A Deck with Lightweight Concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 41 4B Deck with Lightweight Concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 43 4C Deck with Lightweight Concrete New, Reroof (Tear-Off) A-1 Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 48 4D Deck with Lightweight Concrete New or Reroof (Tear-Off) B-3 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50 4E Deck with Lightweight Concrete New or Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 53 4F Deck with Lightweight Concrete Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 58 4G Deck with Lightweight Concrete Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 58 5A Cementitious wood fiber New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 59 5B Cementitious wood fiber New or Reroof (Tear-Off) or Recover B-3 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 60 5C Cementitious wood fiber Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 61 5D Cementitious wood fiber New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 62 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 63 6B Existing gypsum Reroof (Tear-Off) B-3 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 65 6C Existing gypsum Reroof (Tear-Off) C-1 Mechanically Attached Insulation, Bonded Roof Cover 66 6D Existing gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 66 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 67 7B Various Recover F Non-Insulated, Bonded Roof Cover 74 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 2 of 74 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY FBC PARTS MINIMUM ENGAGEMENT Wood Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #14 HD with Trufast 3” Metal Insulation Plates Minimum ¾-inch plywood penetration or minimum 1-inch wood plank embedment OMG, Inc. FL699 OMG #14 Roofgrip with AccuTrac Plates or OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate SFS Group USA, Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Steel Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates Minimum ¾-inch steel penetration and engage the top flute of the steel deck OMG, Inc. FL699 OMG #12 or #14 Roofgrip with AccuTrac Plates or OMG #12 Standard or OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate SFS Group USA, Inc. FL20311 Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Structural Concrete Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #14 HD or Trufast Fluted Concrete Nail with Trufast 3” Metal Insulation Plates Minimum 1-inch embedment. Fastener installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions OMG, Inc. FL699 OMG #14 Roofgrip with AccuTrac Plates or OMG #14 Heavy Duty or CD-10 with OMG 3 in. Galvalume Steel Plate SFS Group USA, Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch FBC Approved lightweight insulating concrete may be substituted for, or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the Lightweight Concrete and the potential effect on overlying components. 5 Preliminary insulation attachment: Unless otherwise noted, use FBC Approved roofing fasteners and plates and refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29. 6 Unless otherwise noted, insulation adhesive application rates are as follows. • Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. • If applying hot asphalt to concrete deck, deck shall be primed with ASTM D41 primer. • When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. • The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. INSULATION ADHESIVE REFERENCES BY FBC ADHESIVE REFERENCE MINIMUM RATE NOTE DuPont de Nemours, Inc. FL720 Insta Stik Quik Set Insta Stick Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c H.B. Fuller Company FL1800 Millennium One Step Foamable Adhesive M-OSFA Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. Millennium PG-1 Pump Grade Adhesive M-PG1 Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. Millennium PG-1 EF ECO M-PG1-EF-ECO Continuous 1 to 1.5-inch wide ribbons, 12-inch o.c. ICP Construction, Inc. FL22256 Polyset Board-Max Polyset BM Continuous 3-inch wide ribbons, 12-inch o.c. FL1365 Polyset Commercial Roofing Adhesive Polyset CRA Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. Formerly Polyset CR-20 OMG, Inc. FL1608 OlyBond 500 Adhesive Fastener OB500 Continuous 0.75-inch wide ribbons, 12-inch o.c. PaceCart, SpotShot or Canister dispensing Generic, ASTM D312, Type IV N/A hot asphalt N/A Full coverage at 25-30 lbs/square If applying hot asphalt to concrete deck, deck shall be primed with ASTM D41 primer NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 3 of 74 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS ADHESIVE INSULATION MIN. TAPERED THICKNESS (IN) MDP (PSF) LISTED PRODUCT FBC Insta Stik Any polyisocyanurate listed with adhesive herein Various 1.0 -120.0 M-OSFA Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5 M-PG1 Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5 Polyset CRA Any polyisocyanurate listed with adhesive herein Various 1.0 -117.5 OB500 Rmax Multi-Max FA3 FL11207 0.5 -45.0 OB500 Hunter H-Shield FL5968 0.5 -315.0 OB500 Johns Manville ENRGY 3 FL4205 0.5 -315.0 OB500 Atlas Roofing ACFoam II FL17989 0.5 -487.5 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29. 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 or RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. For systems using Trufast Versa-Fast, the number of Versa-Fast Fasteners installed through the Versa-Fast Plate may be increased from the minimum noted in order to yield minimum required withdrawal resistance. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top- coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 4 of 74 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-CA1 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Karnak No. 81 Cold Process Modified Bitumen Adhesive Brush Grade at 1 gal/square Note: Base ply cures overnight prior to application of the ply or cap ply. Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS BP-CA2 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square. SBS-CA2 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS BP-CA3 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 HB Fuller “Millennium Hurricane Force Membrane Adhesive”, beads spaced 6-inch o.c. SBS-CA3 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS SBS-CA4 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base FlintBond Brush or Tropical Roofing Products #216 Modified Bitumen Adhesive at 1 to 1.5 gal/square. Note: Base ply cures overnight prior to application of the ply or cap ply. Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS BP-AA Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4 BP-AA2 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 Base Ply: Flintglas MS Cap (inverted) hot asphalt in 9-inch wide ribbons spaced as noted herein. SBS-AA Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square Ply: One or more Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS SBS-TA Base Ply: Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T APP-TA Base Ply: One or more Flintlastic APP Base T, Flintlastic STA torch-applied Cap Ply: Flintlastic STA, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar SBS-SA-H Base Ply: Black Diamond Base Sheet, Flintlastic Ultra Glass SA self-adhering (activated by overlying membrane) SBS-SA Base Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply self-adhering Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply Cap Ply: Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 5 of 74 16 Thermal Barrier and/or Vapor Barrier Options: 16A Structural Concrete Decks: The lesser of the MDP listings below vs. that for the selected assembly applies. CONCRETE DECKS: VAPOR BARRIER OPTIONS, FOLLOWED BY BONDED INSULATION OPTION # PRIMER VAPOR BARRIER ADHESIVE PER TABLE 3A (Notes 6,7,8) MDP (PSF) TYPE ATTACH C-VB-1. FlintPrime QD Flintlastic SA PlyBase Self-adhering OB500, 12-inch o.c. -82.5 C-VB-2. None All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, max. 6-inch o.c. M-OSFA or M-PG1, 12-inch o.c. -82.5 C-VB-3. None Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, max. 6-inch o.c. M-OSFA or M-PG1, 12-inch o.c. -82.5 C-VB-4. FlintPrime QD Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 12-inch o.c. -97.5 C-VB-5. FlintPrime QD Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 6-inch o.c. -315.0 C-VB-6. FlintPrime QD Flintlastic GTA Torch-applied M-OSFA or M-PG1, 12-inch o.c. -420.0 C-VB-7. FlintPrime QD Flintlastic Base 20 T Torch-applied M-OSFA or M-PG1, 12-inch o.c. -495.0 17 The following products are interchangeable within the scope of this Evaluation Report. ACCEPTABLE ALTERNATES SUB-CATEGORY MANUFACTURER FBC LISTED PRODUCT HEREIN ALTERNATE Adhesives H.B. Fuller Company FL1800 M-OSFA FlintFast QS Insulation Adhesive M-PG1 FlintFast LV Insulation Adhesive Roofing Fasteners Altenloh, Brinck and Co. U.S., Inc. FL4500 Trufast #12 DP FlintFast #12 Fastener Trufast #14 HD FlintFast #14 Fastener Trufast #15 EHD FlintFast #15 EHD Fastener Trufast 2” Barbed Metal Seam Plate FlintFast 2” Barbed Seam Plate Trufast 2.4” Barbed Metal Seam Plate FlintFast 2.4” Barbed Seam Plate Trufast 3” Metal Insulation Plate FlintFast 3” Insulation Plate Roofing Insulation Atlas Roofing FL17989 ACFoam II FlintBoard ISO ACFoam III FlintBoard ISO Cold Hunter Panels FL5968 H-Shield FlintBoardH ISO H-Shield CG FlintBoardH ISO Cold Georgia-Pacific Gypsum, LLC FL1250 DensDeck Prime DensDeck StormX Prime Roof Board 18 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. (Notes 9 and 10) NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 6 of 74 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-1 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 W-2 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield OB500 (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board. OB500 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 W-3 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1, 6- inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -97.5 W-4 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield OB500, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board. OB500, 6- inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -97.5 HYBRID SYSTEMS: W-5 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1 None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-6 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield OB500 (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board. OB500 None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-7 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1, 6- inch o.c. None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -97.5 W-8 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield OB500, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board. OB500, 6- inch o.c. None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -97.5 CONVENTIONAL SYSTEMS: W-9 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1 Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-10 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch ACFoam II or H-Shield OB500 (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board. OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-11 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M-PG1, 6- inch o.c. Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA or M-PG1, 6- inch o.c. None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -97.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 7 of 74 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-12 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch ACFoam II or H-Shield OB500, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board. OB500, 6- inch o.c. None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -97.5 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-13 Min. 15/32-inch plywood, 24- inch span Min. 2-inch ACFoam II or H- Shield Note 2 1 per 2.7 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -30.0 W-14 Min. 15/32-inch plywood, 24- inch span Min. 2-inch ACFoam II or H- Shield Dekfast DF-#14-PH3 with Dekfast PLT-R-3 1 per 2.0 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -52.5 HYBRID SYSTEMS: W-15 Min. 15/32-inch plywood, 24- inch span Min. 2-inch ACFoam II or H- Shield Note 2 1 per 2.7 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -30.0 W-16 Min. 15/32-inch plywood, 24- inch span Min. 2-inch ACFoam II or H- Shield Dekfast DF-#14-PH3 with Dekfast PLT-R-3 1 per 2.0 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-17 Min. 15/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.3 ft2 Min. 1.5-inch ACFoam II or H-Shield hot asphalt, M-OSFA, M-PG1 Insta Stik, OB500 SBS-SA-H (Optional) APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: W-18 Min. 23/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-19 Min. 23/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 8 of 74 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-20 Min. 15/32-inch plywood, 24- inch span Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.3 ft2 Optional additional layer(s) of base insulation followed by Min. 0.25- inch SECUROCK Gypsum-Fiber Roof board hot asphalt, M-OSFA, M-PG1, Insta Stik, OB500 APP-TA (Optional) APP-TA APP-TA -90.0 COLD-APPLIED SYSTEMS: W-21 Min. 15/32-inch plywood, 24- inch span Min. 2-inch ACFoam II or H- Shield Note 2 1 per 2.7 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-CA4 None SBS-CA4 -30.0 W-22 Min. 15/32-inch plywood, 24- inch span Min. 2-inch ACFoam II or H- Shield Dekfast DF-#14-PH3 with Dekfast PLT-R-3 1 per 2.0 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-CA4 None SBS-CA4 -45.0 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-23 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4- inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -45.0* W-24 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch DensDeck hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -52.5 W-25 Min. 19/32- inch plywood, 24-inch span Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -52.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 9 of 74 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-26 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -60.0 W-27 Min. 19/32- inch plywood, 24-inch span Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: W-28 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4- inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt None N/A None SBS-SA-H (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0* W-29 Min. 19/32- inch plywood at max. 24- inch Glasbase Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt None N/A None SBS-SA-H (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 CONVENTIONAL SYSTEMS: W-30 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS or Flintglas MS Cap (inverted) 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4- inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0* W-31 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch DensDeck hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. FlintPrime QD BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -52.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 10 of 74 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-32 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3- inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi- Max FA3 hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 4-inch o.c. Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt full coverage or M- OSFA, Insta Stik, OB500, Polyset BM or Polyset CRA, 6-inch o.c. None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 3, Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-33 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 3.2 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -30.0* W-34 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.3 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0 W-35 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-36 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or Multi- Max FA3 Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-37 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -52.5 W-38 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield or Multi- Max FA3 Note 2 1 per 1.45 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 HYBRID SYSTEMS: W-39 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -30.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 11 of 74 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 3, Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply W-40 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 None SBS-SA-H (Optional) SBS- TA or APP-TA APP-TA -52.5 W-41 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA-H (Optional) BP-AA or SBS-AA SBS-AA -52.5 W-42 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Note 2 1 per 1.45 ft2 None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-43 Min. 15/32-inch plywood, 24-inch span (Optional) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None SBS-SA-H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -75.0 W-44 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA-H (Optional) SBS- TA or APP-TA APP-TA -82.5 CONVENTIONAL SYSTEMS: W-45 Min. 23/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.0 ft2 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* W-46 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* W-47 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None APP-TA (Optional) APP- TA APP-TA -60.0 W-48 Min. 19/32-inch plywood, 24-inch span Min. 2-inch ACFoam II, ENRGY 3 or H-Shield, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 W-49 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None APP-TA (Optional) APP- TA APP-TA -67.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 12 of 74 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-50 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -82.5* W-51 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -97.5* W-52 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-53 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -97.5 W-54 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 W-55 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -127.5 CONVENTIONAL SYSTEMS: W-56 Min. 23/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -30.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 13 of 74 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply W-57 Min. 23/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 24-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-58 Min. 23/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-59 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 W-60 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None APP-TA APP-TA -97.5 W-61 Min. 15/32- inch plywood, 24-inch span One or more layers, any thickness or combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. at three (3) equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 W-62 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-63 Min. 19/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG #14 HD with OMG 3 in. Round Metal Plate 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 W-64 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 14 of 74 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply W-65 Min. 15/32- inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-66 Min. 15/32- inch plywood, 24-inch span Min. 1-inch, One or more layers, any combination Loose- laid Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-67 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 9-inch o.c. at min. 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -45.0* W-68 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -52.5 W-69 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -52.5 W-70 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) Flintlastic SA Mid Ply, self- adhering SBS-SA -52.5 W-71 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -60.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 15 of 74 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply W-72 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -67.5 W-73 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 W-74 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Cap nails: 1-inch diameter, 0.032- inch metal cap with 0.120" shank diameter, annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in five (5), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 W-75 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at min. 2-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -105.0 HYBRID SYSTEMS: W-76 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -45.0* W-77 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -52.5 W-78 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -52.5 W-79 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -60.0 W-80 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -82.5 W-81 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 CONVENTIONAL SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 16 of 74 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply W-82 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-83 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-84 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -45.0* W-85 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-86 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-87 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 W-88 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -52.5 W-89 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 W-90 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Cap nails: 1-inch diameter, 0.032- inch metal cap with 0.120-inch shank diameter, annular ring shank nails. 6-inch o.c. at 4-inch lap and 6-inch o.c. at five (5) equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -67.5 W-91 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -82.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 17 of 74 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply W-92 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -90.0 W-93 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -90.0 W-94 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-95 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-96 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -105.0 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-97 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB, 24-inch span Flintlastic SA NailBase Trufast Versa Fastener & Plates, two (2) screws per plate at 180° from each other* 9-inch o.c. at min. 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) Flintlastic SA Mid Ply, self- adhering SBS-SA -60.0* Note: *For re-roof (tear-off) or recover applications, field withdrawal resistance testing (Note 11) shall yield minimum 109 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 1” penetration through OSB sheathing. W-98 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -82.5* W-99 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -97.5* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 18 of 74 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply W-100 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-101 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -97.5 W-102 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA or APP-TA -105.0 W-103 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows FlintPrime QD at stress plates SBS-SA-H SBS-AA or APP-TA -127.5 CONVENTIONAL SYSTEMS: W-104 Min. 23/32-inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -30.0* W-105 Min. 23/32-inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 24- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-106 Min. 23/32-inch plywood, 24-inch span Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* W-107 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 W-108 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None APP-TA APP-TA -97.5 W-109 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. at three (3) equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA or SBS-TA SBS-AA -97.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 19 of 74 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply W-110 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 W-111 Min. 19/32-inch plywood, 24-inch span Flintlastic APP Base T Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG #14 HD with OMG 3 in. Round Metal Plate 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 W-112 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 W-113 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-114 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1H: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply W-115 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing, 24-inch span FlintPrime QD Flintlastic SA Mid Ply, self-adhering (Optional) SBS-SA SBS-SA -90.0 W-116 Min. 15/32-inch plywood, 24-inch span (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -127.5 W-117 Min. 15/32-inch plywood, 24-inch span (Optional) FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -127.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 20 of 74 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: S-1 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 4.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA SBS-SA (Optional) SBS- SA SBS-SA -37.5* S-2 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA SBS-SA (Optional) SBS- SA SBS-SA -45.0* S-3 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Note 2 1 per 2.7 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-SA (Optional) SBS- SA SBS-SA -45.0 S-4 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Dekfast DF-#12-PH3 or Dekfast DF-#14-PH3 with Dekfast PLT-R-3 1 per 2.0 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-SA (Optional) SBS- SA SBS-SA -52.5 S-5 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Dekfast DF-#12-PH3 or Dekfast DF-#14-PH3 with Dekfast PLT-R-3 1 per 1.6 ft2 Min. 2.5-inch H-Shield HD Composite CG M-OSFA or M- PG1, 6-inch o.c. SBS-SA (Optional) SBS- SA SBS-SA -82.5 HYBRID SYSTEMS: S-6 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 1.45 ft2 Additional layer(s) base insulation hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -37.5 S-7 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Note 2 1 per 2.7 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0 S-8 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 1.45 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, APP-TA -52.5 S-9 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Dekfast DF-#12-PH3 or Dekfast DF-#14-PH3 with Dekfast PLT-R-3 1 per 2.0 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 21 of 74 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-10 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP or #14 HD with Trufast 3”Metal Insulation Plates 1 per 1.45 ft2 Min. 1.5-inch ACFoam II or H- Shield hot asphalt, M- OSFA, M-PG1, Insta Stik, OB500 SBS-SA-H (Optional) APP- TA APP-TA -67.5 S-11 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1, Insta Stik, OB500 SBS-SA-H (Optional) SBS- TA or APP-TA APP-TA -75.0 S-12 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Dekfast DF-#12-PH3 or Dekfast DF-#14-PH3 with Dekfast PLT-R-3 1 per 1.6 ft2 Min. 2.5-inch H-Shield HD Composite CG M-OSFA or M- PG1, 6-inch o.c. SBS-SA-H (Optional) SBS- TA or APP-TA APP-TA -82.5 S-13 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-SA-H (Optional) SBS- TA or APP-TA APP-TA -90.0* CONVENTIONAL SYSTEMS: S-14 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 4.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-15 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). hot asphalt BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-16 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch DensDeck or DensDeck Prime hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-17 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 22 of 74 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-18 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 3.2 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). hot asphalt BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-19 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 3.2 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch DensDeck or DensDeck Prime hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-20 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 Min. 0.75-inch FescoBoard (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 S-21 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Note 2 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, M- OSFA, Insta Stik, OB500, Polyset BM, Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 S-22 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 Min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -67.5 S-23 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1, Insta Stik, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -75.0 S-24 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -90.0* COLD-APPLIED SYSTEMS: S-25 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Min. 1.5-inch ACFoam III or H-Shield CG OB500 or Polyset CRA SBS-CA1 None SBS-CA1 -45.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 23 of 74 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-26 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik, M- OSFA, M-PG1, OB500, Polyset BM or Polyset CRA SBS-CA1 None SBS-CA1 -45.0* S-27 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik, M- OSFA, M-PG1, OB500, Polyset BM or Polyset CRA SBS-CA4 None SBS-CA4 -45.0* S-28 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II or H- Shield Note 2 1 per 2.7 ft2 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 SBS-CA4 None SBS-CA4 -45.0 S-29 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M-PG1, Insta Stik, OB500 SBS-CA1 None SBS-CA1 -75.0 S-30 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-CA1 None SBS-CA1 -90.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 24 of 74 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 3, Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: S-31 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -30.0* S-32 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -37.5* S-33 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* S-34 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.3 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0 S-35 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -67.5 S-36 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -82.5 S-37 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -97.5 HYBRID SYSTEMS: S-38 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Note 2 1 per 2.0 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -30.0* S-39 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-40 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-41 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -67.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 25 of 74 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 3, Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply S-42 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -75.0 S-43 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -82.5 S-44 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -82.5 S-45 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -82.5 S-46 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II or H- Shield Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -97.5 S-47 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA APP-TA -135.0 CONVENTIONAL SYSTEMS: S-48 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.7 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -30.0* S-49 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-50 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-51 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 26 of 74 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 3, Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply S-52 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.0 ft2 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-53 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime Note 2 1 per 2.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-54 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None APP-TA (Optional) APP- TA APP-TA -60.0 S-55 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, ENRGY 3 or H-Shield, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.8 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 S-56 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -82.5 S-57 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch DensDeck Prime Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -112.5 S-58 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -135.0 S-59 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -157.5 S-60 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch DensDeck Prime Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -157.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 27 of 74 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 3, Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply S-61 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II or H-Shield Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -172.5 SPOT- OR STRIP-MOPPED SYSTEMS: S-62 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch ACFoam II or ENRGY 3 Note 2 1 per 1.6 ft2 None BP-AA2 (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -37.5* S-63 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1-inch FescoBoard (homogeneous) or min. 1.5- inch FescoBoard (laminated) Note 2 1 per 1.6 ft2 None BP-AA2 (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-64 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek HD with Primed Red Coating Note 2 1 per 2.0 ft2 None BP-AA2 (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* S-65 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Note 2 1 per 1.45 ft2 None BP-AA3, 24-inch grid (Optional) BP-AA or SBS-AA SBS-AA -52.5 S-66 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II Note 2 1 per 1.45 ft2 None BP-AA3, 24-inch grid BP-AA or SBS-AA SBS-TA -52.5 COLD-APPLIED SYSTEMS: S-67 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA1 None SBS-CA1 -37.5* S-68 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA4 None SBS-CA4 -37.5* S-69 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam III or H-Shield CG Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None SBS-CA1 None SBS-CA1 -45.0* S-70 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA1 None SBS-CA1 -45.0* S-71 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA4 None SBS-CA4 -45.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 28 of 74 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 3, Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply S-72 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-CA1 None SBS-CA1 -82.5* TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: S-73 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 9-inch o.c. at min. 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -45.0* S-74 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -52.5* S-75 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -60.0* S-76 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase (laid parallel to deck flutes) Note 2 8-inch o.c. at min. 4-inch lap and 8- inch o.c. in two (2), equally spaced, staggered center rows, FlintPrime QD at stress plates (Optional) SBS- SA SBS-SA -82.5* CONVENTIONAL SYSTEMS: S-77 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -30.0* S-78 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 4-inch lap and 24- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* S-79 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 29 of 74 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply S-80 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 18-inch o.c. at 4-inch lap and 18- inch o.c. in one (1) staggered center row BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -45.0* S-81 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Dekfast DF-#14-PH3 with PLT-R-2-4B 12-inch o.c. within the min. 4-inch wide, heat-welded side lap SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* S-82 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Note 2 12-inch o.c. at 3-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -52.5 S-83 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2” Barbed Metal Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -52.5 S-84 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Barbed Metal Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -60.0 S-85 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -67.5 S-86 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet or Flintglas MS Cap (inverted) OMG #14 HD with OMG Flat Bottom Plates (AccuTrac) 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -67.5 S-87 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Base 20 or Flintglas MS Cap (inverted) Note 2 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA or APP-TA -67.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 30 of 74 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply S-88 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. at three (3) equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA -97.5 S-89 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 6-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA APP-TA -112.5 S-90 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-TA or APP- TA APP-TA -112.5 S-91 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-AA SBS-AA -120.0 S-92 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 6-inch o.c. within the min. 4-inch wide, heat-welded side laps and 6- inch o.c. in one (1) center row, stripped-in with 6-inch side strips of torch-applied Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet. (Optional) SBS- TA or APP-TA APP-TA -165.0 COLD-APPLIED SYSTEMS: S-93 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 6-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-CA1 SBS-CA1 -45.0* S-94 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1-inch, One or more layers, any combination Loose-laid Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 12- inch o.c. in three (3), equally spaced, staggered center rows (Optional) SBS- CA1 SBS-CA1 -75.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 31 of 74 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: C-1. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-2. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.25-inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 C-3. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -97.5 C-4. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 2-inch H-Shield HD Composite CG M-OSFA or M- PG1 None SBS-SA (Optional) SBS-SA SBS-SA -142.5 C-5. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-6. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 M-OSFA or M- PG1 Min. 0.25-inch DensDeck M-OSFA or M- PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 C-7. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -315.0 C-8. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -315.0 C-9. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 2-inch H-Shield HD Composite CG M-OSFA or M- PG1, 6-inch o.c. None SBS-SA (Optional) SBS-SA SBS-SA -342.5 C-10. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF-ECO Min. 0.5-inch H-Shield HD M-PG1-EF-ECO FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -97.5 C-11. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF-ECO Min. 2-inch H-Shield HD Composite CG M-PG1-EF-ECO None SBS-SA (Optional) SBS-SA SBS-SA -142.5 C-12. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-PG1-EF-ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF-ECO None SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-13. Structural concrete (Optional) FlintPrime QD Min. 1.5-inch Multi-Max FA Insta Stik Min. 0.25-inch DensDeck Insta Stik FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 C-14. Structural concrete (Optional) FlintPrime QD Min. 1.5-inch ENRGY 3 Insta Stik Min. 0.25-inch DensDeck Insta Stik FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -112.5 C-15. Structural concrete (Optional) FlintPrime QD Min. 1.5-inch ACFoam II Insta Stik Min. 0.25-inch DensDeck Insta Stik FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -120.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 32 of 74 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-16. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-17. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -120.0 C-18. Structural concrete None Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -150.0 C-19. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-20. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 C-21. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch DensDeck Polyset BM or Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: C-22. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II or H- Shield hot asphalt (Optional) Additional layer(s) base insulation hot asphalt None Flintlastic Ultra Glass SA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -322.5 C-23. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II or H- Shield hot asphalt (Optional) Additional layer(s) base insulation hot asphalt None Black Diamond Base Sheet (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -375.0 C-24. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -97.5 C-25. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 2-inch H-Shield HD Composite CG M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -142.5 C-26. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Additional layer(s) base insulation M-OSFA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -232.5 C-27. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -217.5 C-28. Structural concrete None Min. 1-inch Styrofoam Brand Roofmate M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -210.0 C-29. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None N/A None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -195.0 C-30. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1 (Optional) Additional layer(s) base insulation M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -270.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 33 of 74 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-31. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -217.5 C-32. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -195.0 C-33. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch ACFoam- HD CoverBoard or H-Shield HD M-OSFA or M- PG1, 6-inch o.c. None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -315.0 C-34. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 2-inch H-Shield HD Composite CG M-OSFA or M- PG1, 6-inch o.c. None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -342.5 C-35. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF-ECO Min. 0.5-inch H-Shield HD M-PG1-EF-ECO None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -97.5 C-36. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF-ECO Min. 2-inch H-Shield HD Composite CG M-PG1-EF-ECO None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -142.5 C-37. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF-ECO None N/A None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -195.0 C-38. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1-EF-ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF-ECO None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -217.5 C-39. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1-EF-ECO (Optional) Additional layer(s) base insulation M-PG1-EF-ECO None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -247.5 C-40. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik (Optional) Additional layer(s) base insulation Insta Stik None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -135.0 C-41. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -217.5 C-42. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None N/A None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -195.0 C-43. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 (Optional) Additional layer(s) base insulation OB500 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -135.0 C-44. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -217.5 C-45. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None N/A None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -195.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 34 of 74 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-46. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA (Optional) Additional layer(s) base insulation Polyset BM or Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -270.0 C-47. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -217.5 C-48. Structural concrete None Min. 1.5-inch, min. 1.5 pcf Insulfoam II Roofing EPS Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -180.0 C-49. Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam IX Roofing EPS Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -217.5 C-50. Structural concrete None Min. 1.5-inch Styrofoam Brand Roofmate Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -217.5 C-51. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None N/A None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, APP-TA -195.0 CONVENTIONAL SYSTEMS: C-52. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime hot asphalt None SBS-TA (Optional) SBS-TA SBS-TA -180.0 C-53. Structural concrete FlintPrime QD (Optional) Min. 1.5-inch ACFoam II hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -180.0 C-54. Structural concrete FlintPrime QD (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -225.0 C-55. Structural concrete FlintPrime QD (Optional) Min. 1.5-inch ACFoam II or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None APP-TA (Optional) APP-TA APP-TA -252.5 C-56. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.5-inch Structodek High Density Fiberboard hot asphalt None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -227.0 C-57. Structural concrete FlintPrime QD (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-TA or APP- TA (Optional) SBS-TA or APP-TA APP-TA -232.5 C-58. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt Min. 0.25-inch DensDeck hot asphalt None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -240.0 C-59. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II hot asphalt Min. 0.75-inch FescoBoard (homogeneous) hot asphalt None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -412.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 35 of 74 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-60. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II hot asphalt Min. 0.5-inch DuraBoard (homogeneous) hot asphalt None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -430.0 C-61. Structural concrete FlintPrime QD 0.5-inch Structodek High Density Fiberboard or min. 0.75- inch Fesco Board (homogeneous) hot asphalt None N/A None BP-AA (Optional) BP-AA or SBS-AA SBS-AA -437.5 C-62. Structural concrete FlintPrime QD 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board hot asphalt None N/A None SBS-TA (Optional) SBS-AA or SBS-TA SBS-AA -302.5 C-63. Structural concrete FlintPrime QD 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board hot asphalt None N/A None BP-AA (Optional) BP-AA or SBS-AA SBS-AA -537.5 C-64. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.5-inch Structodek High Density Fiberboard M-OSFA None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 C-65. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-PG1 Min. 0.5-inch Structodek High Density Fiberboard M-PG1 None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -180.0 C-66. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch DensDeck M-OSFA None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -232.5 C-67. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-PG1 Min. 0.25-inch DensDeck M-PG1 None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -240.0 C-68. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1 Min. 0.25-inch DensDeck Prime M-PG1 None BP-AA, SBS-AA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA -297.5 C-69. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -225.0 C-70. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-TA or APP- TA (Optional) SBS-TA or APP-TA APP-TA -232.5 C-71. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None APP-TA (Optional) APP-TA APP-TA -252.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 36 of 74 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-72. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None BP-AA, SBS-AA or SBS-TA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA -297.5 C-73. Structural concrete None 0.5-inch Structodek High Density Fiberboard M-PG1 None N/A None BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 C-74. Structural concrete None Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 C-75. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None SBS-AA or SBS- TA (Optional) SBS-AA or SBS-TA SBS-AA -315.0 C-76. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1, 6-inch o.c. None Flintlastic STA (Optional) APP-TA APP-TA -315.0 C-77. Structural concrete None Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1-EF-ECO None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 C-78. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1-EF-ECO Min. 0.25-inch DensDeck Prime M-PG1-EF-ECO None BP-AA, SBS-AA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA -247.5 C-79. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield M-PG1-EF-ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF-ECO None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -247.5 C-80. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch DensDeck Prime Insta Stik None BP-AA, SBS-AA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA -297.5 C-81. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -225.0 C-82. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None SBS-TA or APP- TA (Optional) SBS-TA or APP-TA APP-TA -232.5 C-83. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None APP-TA (Optional) APP-TA APP-TA -252.5 C-84. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield Insta Stik Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None BP-AA, SBS-AA or SBS-TA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA -297.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 37 of 74 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-85. Structural concrete None 0.5-inch Structodek High Density Fiberboard Insta Stik None N/A None BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 C-86. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 C-87. Structural concrete None Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 C-88. Structural concrete None Min. 1.5-inch ACFoam II OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -150.0 C-89. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch DensDeck Prime OB500 None BP-AA, SBS-AA or SBS-TA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA -297.5 C-90. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -225.0 C-91. Structural concrete None Min. 2-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-TA or APP- TA (Optional) SBS-TA or APP-TA APP-TA -232.5 C-92. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None APP-TA (Optional) APP-TA APP-TA -252.5 C-93. Structural concrete None Min. 1.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA or SBS-TA (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA -297.5 C-94. Structural concrete None 0.5-inch Structodek High Density Fiberboard OB500 None N/A None BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 C-95. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 C-96. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -180.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 38 of 74 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-97. Structural concrete None Min. 1-inch ENRGY 3, H-Shield, or H-Shield CG, min. 1.3-inch ACFoam III or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -225.0 C-98. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-TA or APP- TA (Optional) SBS-TA or APP-TA APP-TA -232.5 C-99. Structural concrete None Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch DensDeck Polyset BM or Polyset CRA None BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -240.0 C-100. Structural concrete None 0.5-inch Structodek High Density Fiberboard Polyset BM or Polyset CRA None N/A None BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 C-101. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None N/A None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 SPOT- OR STRIP-MOPPED SYSTEMS: C-102. Structural concrete FlintPrime QD Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield hot asphalt (Optional) Additional layer(s) of base insulation hot asphalt None BP-AA3, 24- inch grid (Optional) BP-AA, SBS-AA SBS-AA -37.5 COLD-APPLIED SYSTEMS: C-103. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch DEXcell FA Glass Mat Roof Board M-OSFA or M- PG1 None Flintlastic Poly SMS Base Sheet in Karnak #81 (Optional) Flintlastic Poly SMS Base Sheet in Karnak #81 SBS-CA1 -90.0 C-104. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -97.5 C-105. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -97.5 C-106. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 2-inch H-Shield HD Composite CG M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -97.5 C-107. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA1 None SBS-CA1 -105.0 C-108. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M- PG1 None SBS-CA4 None SBS-CA4 -105.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 39 of 74 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-109. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DEXcell FA Glass Mat Roof Board M-OSFA or M- PG1, 6-inch o.c. None Flintlastic Poly SMS Base Sheet in Karnak #81 (Optional) Flintlastic Poly SMS Base Sheet in Karnak #81 SBS-CA1 -112.5 C-110. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF-ECO Min. 0.5-inch H-Shield HD M-PG1-EF-ECO None SBS-CA1 None SBS-CA1 -97.5 C-111. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF-ECO Min. 0.5-inch H-Shield HD M-PG1-EF-ECO None SBS-CA4 None SBS-CA4 -97.5 C-112. Structural concrete None (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF-ECO Min. 2-inch H-Shield HD Composite CG M-PG1-EF-ECO None SBS-CA4 None SBS-CA4 -97.5 C-113. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield M-PG1-EF-ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF-ECO None SBS-CA1 None SBS-CA1 -105.0 C-114. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield M-PG1-EF-ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF-ECO None SBS-CA4 None SBS-CA4 -105.0 C-115. Structural concrete None (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 1.5-inch ACFoam III or H-Shield CG OB500 None SBS-CA1 None SBS-CA1 -82.5 C-116. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0 C-117. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0 C-118. Structural concrete None (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM or Polyset CRA Min. 1.5-inch ACFoam III or H-Shield CG Polyset BM or Polyset CRA None SBS-CA1 None SBS-CA1 -82.5 C-119. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-CA1 None SBS-CA1 -105.0 C-120. Structural concrete None Min. 0.5-inch ACFoam II or H- Shield Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-CA4 None SBS-CA4 -105.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 40 of 74 TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: C-121. Structural concrete FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -630.0 HYBRID SYSTEMS: C-122. Structural concrete FlintPrime QD Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0 C-123. Structural concrete FlintPrime QD SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0 C-124. Structural concrete FlintPrime QD Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5 C-125. Structural concrete FlintPrime QD SBS-SA-H (Optional) BP-AA, SBS-AA SBS-AA -240.0 C-126. Structural concrete FlintPrime QD BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0 CONVENTIONAL SYSTEMS: C-127. Structural concrete FlintPrime QD APP-TA (Optional) APP-TA APP-TA -420.0 C-128. Structural concrete FlintPrime QD BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -635.0 COLD-APPLIED SYSTEMS: C-129. Structural concrete FlintPrime QD SBS-CA1 (Optional) SBS-CA1 SBS-CA1 -262.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 41 of 74 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-1 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-OSFA SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-2 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-PG1 SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-3 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-4 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-5 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset CRA SBS-SA (Optional) SBS- SA SBS-SA -52.5 HYBRID SYSTEMS: LWC-6 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA, M-PG1, OB500, Polyset BM, Polyset CRA (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M- PG1, OB500, Polyset BM, Polyset CRA SBS-SA-H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -52.5 CONVENTIONAL SYSTEMS: LWC-7 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-OSFA BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 LWC-8 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-PG1 BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 42 of 74 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-9 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 LWC-10 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset BM BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 LWC-11 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset CRA BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 ELASTIZELL (NOA 18-0208.03): COLD APPLIED SYSTEMS: LWC-12 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP- CA3 or SBS-CA3 SBS-CA3 -60.0 LWC-13 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. When walkable, attach LWC with Trufast #14 HD with Trufast 3” Metal Insulation Plates at 1 per 8 ft2 through to the structural deck. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP- CA3 or SBS-CA3 SBS-CA3 -67.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 43 of 74 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-14 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck M-OSFA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -90.0 LWC-15 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA (Optional) SBS-SA SBS-SA -90.0 LWC-16 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-17 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck M-OSFA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-18 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -217.5 LWC-19 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-20 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 44 of 74 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-21 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-22 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-23 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -240.0 LWC-24 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -232.5 LWC-25 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-26 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-27 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-28 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -180.0 HYBRID SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 45 of 74 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-29 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -90.0 LWC-30 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 LWC-31 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-PG1 (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -232.5 LWC-32 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II or H- Shield M-PG1 (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -240.0 LWC-33 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA or APP- TA -215.0 LWC-34 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM or Polyset CRA (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA or APP- TA -215.0 CONVENTIONAL SYSTEMS: LWC-35 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -90.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 46 of 74 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-36 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-OSFA Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -217.5 LWC-37 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -240.0 LWC-38 Structural concrete Min. 300 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG M-PG1 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-PG1 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -232.5 LWC-39 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -215.0 LWC-40 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -215.0 LWC-41 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 LWC-42 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset CRA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 LWC-43 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H- Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -215.0 ELASTIZELL (NOA 18-0208.03): SELF-ADHERING SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 47 of 74 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-44 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -150.0 LWC-45 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-46 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-47 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -180.0 CONVENTIONAL SYSTEMS: LWC-48 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -150.0 LWC-49 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 2-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -225.0 LWC-50 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 LWC-51 Structural concrete Min. 200 psi, min. 2-inch Elastizell Min. 1-inch ENRGY 3, H- Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset CRA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -180.0 COLD APPLIED SYSTEMS: LWC-52 Structural concrete Min. 350 psi, min 2-inch Elastizell with Zell-Crete Fibers. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. None BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 48 of 74 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-53 Structural concrete Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. When walkable, attach LWC with Trufast #14HD with Trufast 3” Metal Insulation Plates at 1 per 8 ft2 through to the structural deck. Min. 1.5-inch H-Shield CG OB500, 6- inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. None BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -67.5 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Vapor Barrier Base Insulation Layer Coverboard Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply PRE-EXISTENT CELLULAR LWC: SELF-ADHERING SYSTEMS: LWC-54 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch- welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2- inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-55 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch- welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2- inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: LWC-56 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch- welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2- inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 ELASTIZELL (NOA 18-0208.03): SELF-ADHERING SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 49 of 74 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Vapor Barrier Base Insulation Layer Coverboard Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-57 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3- inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2- inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 LWC-58 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch- welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2- inch ACFoam II or H-Shield M-OSFA or M-PG1 (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-59 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3- inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2- inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -67.5 LWC-60 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch- welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2- inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-SA-H (Optional) SBS-TA or APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: LWC-61 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3- inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2- inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 LWC-62 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6- inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch- welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2- inch ACFoam II or H-Shield M-OSFA or M-PG1 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 (Optional) FlintPrime QD SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 50 of 74 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasten (Note 11) Attach Base Top Attach Base Ply Ply Cap Ply PRE-EXISTENT CELLULAR LWC: SPOT- OR STRIP-MOPPED SYSTEMS: LWC-63 Min. 22 ga. steel or structural concrete deck. None Min 350 psi, min 2-inch pre- existent cellular LWIC None Flintglas MS Cap (inverted) Trufast Twin- Loc Nails 9-inch o.c. at the 4-inch side lap and 9-inch o.c. at two, equally spaced, staggered rows in the center of the sheet Min. 1.5- inch ACFoam II (Optional) Additional layers base insulation Hot asphalt BP-AA4, 18-inch o.c. (Optional) BP-AA, SBS- AA SBS-AA -60.0 Note: To qualify the LWIC under this assembly, the subject fastener shall achieve an average withdrawal of 88 lbf when tested per Note 11. CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-64 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.25- inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface shall be primed with FlintPrime QD. hot asphalt SBA-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: LWC-65 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.125- inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 CONVENTIONAL SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 51 of 74 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasten (Note 11) Attach Base Top Attach Base Ply Ply Cap Ply LWC-66 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board, min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch Fesco Board (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 LWC-67 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -60.0 ELASTIZELL (NOA 18-0208.03): SELF-ADHERING SYSTEMS: LWC-68 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.25- inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface shall be primed with FlintPrime QD. hot asphalt SBA-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-69 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II (Optional) Min. 0.125- inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -67.5 CONVENTIONAL SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 52 of 74 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasten (Note 11) Attach Base Top Attach Base Ply Ply Cap Ply LWC-70 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board, min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch Fesco Board (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP- TA -67.5 LWC-71 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM- 90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" ACFoam II Min. 0.125-inch STURDY-DEK Asphaltic Cover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with FlintPrime QD. hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -67.5 SPOT- OR STRIP-MOPPED SYSTEMS: LWC-72 Min. 22 ga. steel or structural concrete deck. None Min 350 psi, min 2-inch Elastizell cellular LWIC None Flintglas MS Cap (inverted) Trufast FM- 90 Base Ply Fastener 7-inch o.c. at the 4-inch side lap and 7-inch o.c. at two, equally spaced, staggered rows in the center of the sheet Min. 1.5- inch ACFoam II (Optional) Additional layers base insulation Hot asphalt BP-AA3, 18-inch grid (Optional) BP-AA, SBS- AA SBS-AA -37.5* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 53 of 74 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasten (Note 11) Attach Base Ply Cap Ply PRE-EXISTENT CELLULAR LIGHTWEIGHT CONCRETE: SELF-ADHERING SYSTEMS: LWC-73 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic SA NailBase Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 7-inch o.c. at the min. 2-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows, FlintPrime QD at stress plates SBS-SA SBS-SA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 73 lbf when tested per Note 11. LWC-74 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic SA NailBase Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the min. 2-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows, FlintPrime QD at stress plates SBS-SA SBS-SA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 93 lbf when tested per Note 11. HYBRID SYSTEMS: LWC-75 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per Note 11. LWC-76 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min. 3- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per Note 11. LWC-77 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -75.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per Note 11. CONVENTIONAL SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 54 of 74 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-78 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per Note 11. LWC-79 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 77 lbf when tested per Note 11. LWC-80 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min. 3- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per Note 11. LWC-81 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -75.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per Note 11. CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-82 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Flintlastic SA NailBase Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA -45.0 HYBRID SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 55 of 74 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-83 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 LWC-84 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Flintglas MS Cap (inverted) primed with FlintPrime QD Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 CONVENTIONAL SYSTEMS: LWC-85 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0 LWC-86 Min. 22 ga., type B steel at max. 5 ft spans structural concrete None Min. 300 psi, min 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture. Celcore PVA Curing Compound All Weather/Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fastener 9-inch o.c. at 4-inch laps and 12- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA or SBS- TA SBS-AA -60.0 LWC-87 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min 2- inch Celcore Cellular Concrete. Celcore PVA Curing Compound Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the 3-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -75.0 CONCRECEL (FL5584 & FL10500): CONVENTIONAL SYSTEMS: LWC-88 Min. 22 ga., Type BV, Grade 80 steel, 5 ft span or structural concrete Concrecel Bonding Agent Min. 300 psi, min 2¼- inch Concrecel Concrete. Concrecel Curing Compound Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG CR Base Ply Fastener (1.7) 7-inch o.c. at the 3-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -52.5 ELASTIZELL (NOA 18-0208.03): SELF-ADHERING SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 56 of 74 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-89 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None Flintlastic SA NailBase Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA -45.0 HYBRID SYSTEMS: LWC-90 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fastener or Trufast Twin Loc- Nail Assembled Fastener (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -30.0 LWC-91 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fastener or Trufast Twin Loc- Nail Assembled Fastener (1.8 inch) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 LWC-92 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 LWC-93 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None Flintglas MS Cap (inverted) primed with FlintPrime QD Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA or APP- TA -45.0 CONVENTIONAL SYSTEMS: LWC-94 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fastener or Trufast Twin Loc- Nail Assembled Fastener (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -30.0 LWC-95 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Flintlastic APP Base T Trufast FM-90 Base Sheet Fastener 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -30.0 LWC-96 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 57 of 74 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-97 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) Trufast FM-90 Base Sheet Fastener or Trufast Twin Loc- Nail Assembled Fastener (1.8 inch) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP- TA -45.0 LWC-98 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Flintlastic APP Base T Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0 COLD APPLIED SYSTEMS: LWC-99 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Flintlastic Base 20, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA2 or SBS-CA2 SBS-CA2 -45.0 LWC-100 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Glasbase Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -52.5 LWC-101 Structural concrete None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Glasbase Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fastener 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 MEARLCRETE (FL13492): CONVENTIONAL SYSTEMS: LWC-102 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 250 psi, min 2- inch Mearlcrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG CR Base Ply Fastener (1.7) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -45.0 LWC-103 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 250 psi, min 2- inch Mearlcrete. None Flintlastic Poly SMS Base Sheet OMG CR Base Ply Fastener (1.7) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -52.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 58 of 74 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-104 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min 2- inch Mearlcrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet or Flintglas MS Cap (inverted) OMG CR Base Ply Fastener (1.7) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA or APP- TA -52.5 TABLE 4F: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Surfacing Base Fasten (Note 11) Spacing Base Ply Cap Ply PRE-EXISTENT CELLULAR LWC: LWC-105 Min. 22 ga., Type BV, Grade 40 steel Min. 470 psi, Min. 2- inch, pre-existent cellular lightweight concrete For reroof (tear-off), repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet Trufast Versa Fastener (min. 2.25”) & Plates, two (2) screws per plate at 180° from each other* 9-inch o.c. within the min. 5- inch wide, heat-welded side laps (Optional) SBS-TA or APP-TA APP-TA -75.0 Note: *Field withdrawal resistance testing (Note 11) shall yield minimum 322 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 2.25” embedment into the existing LWC assembly. TABLE 4G: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Roof Cover (Note 15) MDP (psf) Type Surfacing Base Ply Cap Ply PRE-EXISTENT CELLULAR LWC: LWC-106 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” SBS-CA1 or SBS-CA4 -75.0 LWC-107 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch, pre-existent cellular lightweight concrete Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, or Flintlastic GMS, applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, continuous ribbons maximum 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” -97.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 59 of 74 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: CWF-1. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -60.0 CWF-2. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA, 6- inch o.c. FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -90.0 CWF-3. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -45.0* CWF-4. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* CWF-5. Tectum Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch DensDeck Polyset BM or Polyset CRA FlintPrime QD SBS-SA (Optional) SBS- SA SBS-SA -52.5 CWF-6. Tectum Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM or Polyset CRA None SBS-SA (Optional) SBS- SA SBS-SA -52.5 HYBRID SYSTEMS: CWF-7. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 CWF-8. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA, 6- inch o.c. None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -90.0 CONVENTIONAL SYSTEMS: CWF-9. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -60.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 60 of 74 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-10. Tectum Min. 1.5-inch ACFoam II or H- Shield M-OSFA, 6- inch o.c. Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. M-OSFA, 6- inch o.c. None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -90.0 CWF-11. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* CWF-12. Existing Tectum (re- roof only) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -45.0* CWF-13. Tectum Min. 1-inch ENRGY 3, H-Shield, or H-Shield CG, min. 1.3-inch ACFoam III or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 CWF-14. Tectum Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra-Max Polyset BM or Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset BM or Polyset CRA None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA or APP-TA -52.5 TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS: CWF-15. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 CWF-16. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 CONVENTIONAL SYSTEMS: NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 61 of 74 TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-17. Existing Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 CWF-18. Existing Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply CWF-19. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* CWF-20. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 160 lbf) 1 per 1.8 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* CWF-21. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* CWF-22. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 62 of 74 TABLE 5D: CEMENTITOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR REROOF SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: CWF-23. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CWF-24. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: CWF-25. Existing Tectum (reroof only) All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Insuldeck Loc-Nail Base Sheet Fastener (Field W/D > 53 lbf) 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -30.0* CWF-26. Existing Tectum (reroof only) All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Insuldeck Loc-Nail Base Sheet Fastener (Field W/D > 55 lbf) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -45.0* CWF-27. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -60.0 CWF-28. Tectum Glasbase Base Sheet, Flintlastic Base 20 or All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 77 lbf) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA or APP- TA -67.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 63 of 74 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: G-1. Existing gypsum deck Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-2. Existing gypsum deck Min. 1.5-inch ACFoam II, ENRGY 3 or Multi- Max FA3 M-OSFA Min. 0.25-inch DensDeck primed with FlintPrime QD M-OSFA SBS-SA (Optional) SBS-SA SBS-SA -192.5 G-3. Existing gypsum deck One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-4. Existing gypsum deck Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck primed with FlintPrime QD OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0 G-5. Existing gypsum deck One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-6. Existing gypsum deck One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-7. Existing gypsum deck One or more layer(s), min. 1-inch H-Shield or ENRGY 3, min. 1.3-inch ACFoam III or min. 1.5-inch ACFoam II, Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-8. Existing gypsum deck min. 1-inch H-Shield or ENRGY 3, min. 1.3- inch ACFoam III or min. 1.5-inch ACFoam II, Multi-Max FA3 or Ultra-Max Polyset CRA Min. 0.25-inch DensDeck primed with FlintPrime QD Polyset CRA SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: G-9. Existing gypsum deck One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA, M- PG1, OB500, Polyset BM, Polyset CRA (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M- PG1, OB500, Polyset BM, Polyset CRA SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 CONVENTIONAL SYSTEMS: G-10. Existing gypsum deck Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA Min. 0.5-inch Structodek High Density Fiberboard M-OSFA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -127.5 G-11. Existing gypsum deck One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-12. Existing gypsum deck Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield M-OSFA Min. 0.25-inch DensDeck M-OSFA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -232.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 64 of 74 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-13. Existing gypsum deck Min. 2-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -202.5 G-14. Existing gypsum deck One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1 BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-15. Existing gypsum deck Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 G-16. Existing gypsum deck Min. 1.5-inch ACFoam II, ENRGY 3 or H- Shield OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -135.0 G-17. Existing gypsum deck One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-18. Existing gypsum deck One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-19. Existing gypsum deck Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra- Max Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -180.0 G-20. Existing gypsum deck One or more layer(s), min. 1.5-inch ACFoam II, ACFoam III, H-Shield or H-Shield CG Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -187.5 G-21. Existing gypsum deck Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra- Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -225.0 G-22. Existing gypsum deck Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra- Max Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA SBS-TA or APP-TA (Optional) SBS-TA or APP-TA APP-TA -232.5 G-23. Existing gypsum deck Min. 1-inch ENRGY 3, H-Shield or H-Shield CG or min. 1.5-inch Multi-Max FA3 or Ultra- Max Polyset CRA Min. 0.25-inch DensDeck Polyset CRA BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -240.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 65 of 74 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS: G-24. Existing gypsum deck Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt None N/A SBS-SA- H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 G-25. Existing gypsum deck Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt None N/A SBS-SA- H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -60.0 CONVENTIONAL SYSTEMS: G-26. Existing gypsum deck All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast FM-75 or FM-90 Base Sheet Fastener or Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 18- inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, ENRGY 3 or Multi- Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -45.0* G-27. Existing gypsum deck Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 G-28. Existing gypsum deck Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA or APP-TA -60.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 66 of 74 TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply G-29. Existing gypsum deck (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* G-30. Existing gypsum deck (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 160 lbf) 1 per 1.8 ft2 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* G-31. Existing gypsum deck (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* G-32. Existing gypsum deck (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA or APP-TA -45.0* TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: G-33. Existing gypsum deck Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 G-34. Existing gypsum deck Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 88 lbf) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: G-35. Existing gypsum deck All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast FM-75 or FM-90 Base Sheet Fastener or Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA -45.0* G-36. Existing gypsum deck Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA or APP-TA -60.0 G-37. Existing gypsum deck Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintglas MS Cap (inverted) Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA or APP-TA -67.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 67 of 74 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: R-1 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.25-inch DensDeck hot asphalt FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-2 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-3 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD Coverboard or H-Shield HD M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -97.5 R-4 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 None SBS-SA (Optional) SBS-SA SBS-SA -142.5 R-5 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-6 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or Multi-Max FA3 M-OSFA or M- PG1 Min. 0.25-inch DensDeck M-OSFA or M-PG1 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 R-7 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.5-inch ACFoam-HD Coverboard or H-Shield HD M-OSFA or M-PG1, 6- inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -315.0 R-8 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1, 6- inch o.c. None SBS-SA (Optional) SBS-SA SBS-SA -315.0 R-9 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1, 6- inch o.c. FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -315.0 R-10 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 0.5-inch H-Shield HD M-PG1-EF- ECO FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -97.5 R-11 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 2-inch H-Shield HD Composite CG M-PG1-EF- ECO None SBS-SA (Optional) SBS-SA SBS-SA -142.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 68 of 74 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-12 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-PG1-EF- ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF- ECO None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-13 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-14 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-15 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-16 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch DensDeck Polyset BM FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 R-17 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-18 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch DensDeck Polyset CRA FlintPrime QD SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: R-19 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -105.0 R-20 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -97.5 R-21 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -142.5 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 69 of 74 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-22 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 (Optional) Additional layer(s) base insulation M-OSFA or M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 R-23 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 R-24 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch ACFoam- HD CoverBoard or H-Shield HD M-OSFA or M-PG1, 6- inch o.c. None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -315.0 R-25 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1, 6- inch o.c. None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -315.0 R-26 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 0.5-inch H-Shield HD M-PG1-EF- ECO None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -97.5 R-27 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 2-inch H-Shield HD Composite CG M-PG1-EF- ECO None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -142.5 R-28 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO (Optional) Additional layer(s) base insulation M-PG1-EF- ECO None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 R-29 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF- ECO None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 70 of 74 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-30 Existing fully bonded, smooth- or granule- surface BUR or modified bitumen (Optional) Min. 1.5-inch ACFoam II or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -120.0 R-31 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM (Optional) Additional layer(s) base insulation Polyset BM None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 R-32 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional0 Min. 1.5- inch ACFoam II or H- Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 R-33 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen Min. 1.5-inch ACFoam II or H-Shield Polyset CRA (Optional) Additional layer(s) base insulation Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -222.5 R-34 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 CONVENTIONAL SYSTEMS: R-35 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt Min. 0.5-inch Structodek High Density Fiberboard, Min. 0.75-inch FescoBoard (homogeneous) or Min. 0.5-inch DuraBoard (homogeneous) hot asphalt None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 R-36 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 hot asphalt 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -105.0 R-37 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.5-inch Structodek High Density Fiberboard M-OSFA or M-PG1 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -165.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 71 of 74 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-38 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch DensDeck M-OSFA or M-PG1 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -210.0 R-39 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch DensDeck Prime M-OSFA or M-PG1 None BP-AA, SBS-AA, SBS-TA (Optional) BP-AA, SBS- AA or SBS- TA SBS-AA -210.0 R-40 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -210.0 R-41 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1, 6- inch o.c. None SBS-AA or SBS-TA (Optional) SBS-AA or SBS-TA SBS-AA -315.0 R-42 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1, 6- inch o.c. None Flintlastic STA (Optional) APP-TA APP-TA -315.0 R-43 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 0.25-inch DensDeck Prime M-PG1-EF- ECO None BP-AA, SBS-AA, SBS-TA (Optional) BP-AA, SBS- AA or SBS- TA SBS-AA -210.0 R-44 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 2-inch ACFoam II, ENRGY 3 or H-Shield M-PG1-EF- ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF- ECO None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -210.0 R-45 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 R-46 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, ENRGY 3 or H-Shield OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -120.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 72 of 74 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-47 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch DensDeck Polyset BM None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 R-48 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -195.0 R-49 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.5-inch Structodek High Density Fiberboard Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -180.0 R-50 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch DensDeck Polyset CRA None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -222.5 R-51 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA or APP-TA -222.5 COLD-APPLIED SYSTEMS: R-52 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M-PG1 None SBS-CA1 None SBS-CA1 -97.5 R-53 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD M-OSFA or M-PG1 None SBS-CA4 None SBS-CA4 -97.5 R-54 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 2-inch H-Shield HD Composite CG M-OSFA or M-PG1 None SBS-CA4 None SBS-CA4 -97.5 R-55 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 None SBS-CA1 None SBS-CA1 -105.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 73 of 74 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-56 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield M-OSFA or M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 None SBS-CA4 None SBS-CA4 -105.0 R-57 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 0.5-inch H-Shield HD M-PG1-EF- ECO None SBS-CA1 None SBS-CA1 -97.5 R-58 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 0.5-inch H-Shield HD M-PG1-EF- ECO None SBS-CA4 None SBS-CA4 -97.5 R-59 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 2-inch H-Shield HD Composite CG M-PG1-EF- ECO None SBS-CA4 None SBS-CA4 -97.5 R-60 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF- ECO None SBS-CA1 None SBS-CA1 -105.0 R-61 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield M-PG1-EF- ECO Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-PG1-EF- ECO None SBS-CA4 None SBS-CA4 -105.0 R-62 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 1.5-inch ACFoam III or H-Shield CG OB500 None SBS-CA1 None SBS-CA1 -82.5 R-63 Existing fully bonded, smooth- or granule- surface BUR or modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0 R-64 Existing fully bonded, smooth- or granule- surface BUR or modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0 R-65 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM Min. 1.5-inch ACFoam III Polyset BM None SBS-CA1 None SBS-CA1 -82.5 R-66 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-CA1 None SBS-CA1 -105.0 R-67 Existing fully-bonded smooth- or granule- surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset BM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset BM None SBS-CA4 None SBS-CA4 -105.0 NEMO|etc.® NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC NON-HVHZ PEER-CTR-003.A.R31 for FL2533-R30 (NON-HVHZ) Certificate of Authorization #32455 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Revision 31: 08/03/2023 ©2019 NEMO ETC, LLC TOP OF APPENDIX Appendix 1, Page 74 of 74 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-68 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset CRA Min. 1.5-inch ACFoam III or H-Shield CG Polyset CRA None SBS-CA1 None SBS-CA1 -82.5 R-69 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-CA1 None SBS-CA1 -105.0 R-70 Existing fully-bonded smooth- or granule- surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II or H-Shield Polyset CRA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CRA None SBS-CA4 None SBS-CA4 -105.0 TABLE 7B: RECOVER APPLICATIONS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Primer Roof Cover (Note 15) MDP (psf)A Base Ply Ply Cap Ply R-71 Existing fully bonded asphalt built-up roof (BUR) (Optional) FlintPrime QD SBS-CA1 None SBS-CA1 -187.5