Loading...
1820 OCEAN GROVE DRIVE RES24-0051 PERMITOWNER:ADDRESS:CITY:STATE:ZIP: SEAN KILEY 2120 NW 100TH STREET GAINESVILLE FL 37606 COMPANY:ADDRESS:CITY:STATE:ZIP: ACE DOOR & WINDOW SERVICE 2220 Corporate Square Blvd JACKSONVILLE FL 32216 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169622 0000 OCEAN GROVE UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1820 OCEAN GROVE DR RESIDENTIAL WINDOWS/DOORS ONE DOOR $12357.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $115.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: IN-PROGRESS INSPECTIONS ARE REQUIRED FOR EXTERIOR SIDING, WINDOW, AND DOOR INSPECTIONS, AND SHOULD BE SCHEDULED FOR THE FIRST DAY OF WORK. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/6/2024 PERMIT NUMBER RES24-0051 ISSUED: 3/6/2024 EXPIRES: 9/2/2024 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 BUILDING PLAN CHECK 455-0000-322-1001 0 $57.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.59 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $177.09 2 of 2Issued Date: 3/6/2024 PERMIT NUMBER RES24-0051 ISSUED: 3/6/2024 EXPIRES: 9/2/2024 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $177.09 RES24-0051 Address: 1820 OCEAN GROVE DR APN: 169622 0000 $177.09 BUILDING $115.00 BUILDING PERMIT 455-0000-322-1000 0 $115.00 BUILDING PLAN REVIEW $57.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $57.50 STATE SURCHARGES $4.59 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.59 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R26406 $177.09 Printed: Wednesday, March 6, 2024 11:54 AM Date Paid: Wednesday, March 06, 2024 Paid By: ACE DOOR & WINDOW SERVICE Pay Method: CREDIT CARD 10151271838 1 of 1 Cashier: AG Cash Register Receipt City of Atlantic Beach Receipt Number R26406 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: ____________________________________________________ Permit No. ___________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION _____________________________________________________ Permit Type © 2016 R.W. Building Consultants Inc.XXXX105.50" MAX. OVERALL FRAME WIDTH74.50" MAX. OVERALL FRAME WIDTHINSWING/OUTSWING"NON-IMPACT"COMPOSITE EDGEGLAZED FIBERGLASS DOUBLE DOORw/ or w/out SIDELITES98" MAX. O.A. FRAME HEIGHT (INSWING) 97.25" MAX. O.A. FRAME HEIGHT (OUTSWING)TABLE OF CONTENTSSHEET # DESCRIPTIONSHEET # DESCRIPTION1Typical Elevations, Design Pressures & General Notes9Horizontal & Vertical Cross Sections (Direct to Masonry)2 Door Panel Details10Vertical Cross Sections (Thresholds)3Door Panel Details11Buck Anchoring4 Door Panel Details12Frame Anchoring5Sidelite Panel Details13 Hardware Details6Elevations14Glazing details7Horizontal & Vertical Cross Sections (2X Buck)15Components8Horizontal & Vertical Cross Sections (1X Buck)16Bill of MaterialsSee Sheet 6 for Hardware SpecificationsCONFIGURATION ASTRAGALDESIGN PRESSURE (PSF)INSWINGDESIGN PRESSURE (PSF)OUTSWINGPOSITIVE NEGATIVE POSITIVE NEGATIVEXX, OXXOSTANDARD+35.0 -40.0 +35.0 -35.0XX, OXXOCOASTAL+47.0 -47.0 +47.0 -47.0 GENERAL NOTES1. This product has been evaluated and is in compliance with the 8th Edition (2023) FloridaBuilding Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone"(HVHZ).2. Product anchors shall be as listed and spaced as shown on details. Anchor embedmentto base material shall be beyond wall dressing or stucco.3. When used in areas requiring wind borne debris protection, this product is required to beprotected with an impact resistant covering that complies with FBC Sections 1609.1.2 &R301.2.1.2.4. For 2x stud framing construction, anchoring of these units shall be the same as thatshown for 2x buck masonry construction.5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect.6. Fiber-Classic & Smooth-Star Door and Sidelite panels require the use of "J" part numbers and must be stained or painted within six months of installation.OOThis item has been digitally signed and sealed byL. F. Schmidt, P.E. on the date adjacent to the seal.Printed copies of this document are notconsidered signed and sealed and the signaturemust be verified on any electronic copies.THIS PRODUCT APPROVAL IS VALIDONLY FOR THE STATE OF FLORIDAZ:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg Digitally signed by Lyndon F Schmidt Date: 2023.07.19 15:20:28 -04'00' © 2016 R.W. Building Consultants Inc. 95.25" MAX. DOOR PANEL HEIGHT5.5 321240DOOR PANELBOOK95.25" MAX. DOOR PANEL HEIGHT 322295.06" MAX. DOOR PANEL HEIGHT 422235.813" MAX.DOORPANEL WIDTH35.813" MAX.DOORPANEL WIDTH36.0" MAX.DOORPANEL WIDTH41DOOR PANELHybrid Door42DOOR PANELU1 DoorXXX12HORIZONTAL CROSS SECTION22HORIZONTAL CROSS SECTION32VERTICAL CROSS SECTION42VERTICAL CROSS SECTIONEXTERIORINTERIORLOCK STILE(ENGINEERED WOOD)COMPOSITECAP0.5"3.6"1.71"HINGE STILE(ENGINEERED WOOD)0.5"0.7"COMPOSITE CAPEXTERIOR1.71"0.406"0.7"HINGE STILE(ENGINEERED WOOD)LOCK STILE(ENGINEERED WOOD)0.406"3.6"INTERIORCOMPOSITECAPCOMPOSITECAPFIBERGLASS SKIN(0.082" THK.)FOAM CORE(POLYURETHANE -1.9 PCF MIN.)EXTERIORINTERIOR0.89"BOTTOM RAIL(COMPOSITE)1.71"TOP RAIL(COMPOSITE CAP W/LVL ENGINEEREDWOOD)BOTTOM RAIL(COMPOSITE)FIBERGLASS SKIN(0.082" THK.)FOAM CORE(POLYURETHANE -1.9 PCF MIN.)EXTERIORINTERIOR0.89"0.82"1.71"TOP RAIL(COMPOSITE CAP W/LVL ENGINEEREDWOOD)G2G1G2G1G2G1G2G1G2G121.13" MAX.D.L.O.79.13" MAX. D.L.O. 0.82" 5.5 5.5 Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc. 95.25" MAX. DOOR PANEL HEIGHT 331343DOOR PANELBOOK95.25" MAX. DOOR PANEL HEIGHT 332395.06" MAX. DOOR PANEL HEIGHT 432335.813" MAX.DOORPANEL WIDTH35.813" MAX.DOORPANEL WIDTH36.0" MAX.DOORPANEL WIDTH44DOOR PANELHybrid Door45DOOR PANELU1 Door13HORIZONTAL CROSS SECTION23HORIZONTAL CROSS SECTION33VERTICAL CROSS SECTION43VERTICAL CROSS SECTIONEXTERIORINTERIOR1.71"0.5"0.7"HINGE STILE(ENGINEERED WOOD)COMPOSITECAPLOCK STILE(ENGINEERED WOOD)0.5"4.982"G3COMPOSITECAPFOAM CORE(POLYURETHANE -1.9 PCF MIN.)0.89"G3TOP RAIL(COMPOSITE CAP W/LVL ENGINEEREDWOOD)BOTTOM RAIL(COMPOSITE)FIBERGLASS SKIN(0.082" THK.)0.406"0.7"HINGE STILE(ENGINEERED WOOD)0.406"3.6"COMPOSITECAPEXTERIORINTERIOR1.71"LOCK STILE(ENGINEERED WOOD)COMPOSITECAPG3FOAM CORE(POLYURETHANE -1.9 PCF MIN.)0.89"1.71"G3TOP RAIL(COMPOSITE CAP W/LVL ENGINEEREDWOOD)BOTTOM RAIL(COMPOSITE)FIBERGLASS SKIN(0.082" THK.)0.82"1.71"XXX78.81" D.L.O. HEIGHT 23.81" D.L.O.WIDTH0.82" 5.55.5 5.5 Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2017 R.W. Building Consultants Inc.14HORIZONTAL CROSS SECTION24HORIZONTAL CROSS SECTION34VERTICAL CROSS SECTION44VERTICAL CROSS SECTIONEXTERIORINTERIOR0.89"0.88"1.7"G3G30.89"0.89"G31.7"BOTTOM RAIL(COMP.)FIBERGLASS SKIN(0.082" THK.)FOAM CORE(POLYURETHANE -1.9 PCF MIN.)TOP RAIL(COMPOSITE)1.2"LOCK STILE (LVL)1.08"1.53"LOCK STILE (LVL)G3LOCK STILE (LVL)1.53"2'-10" Door Panel95.25" MAX. DOOR PANEL HEIGHT 36.0" MAX.DOORPANEL WIDTHX95.25" MAX. DOOR PANEL HEIGHTX X34142424343424.13" D.L.O.WIDTH63.13" D.L.O. HEIGHT 95.06" MAX. DOOR PANEL HEIGHT46DOOR PANELBOOK47DOOR PANELHybrid Door48DOOR PANELU1 Door35.813" MAX.DOORPANEL WIDTH35.813" MAX.DOORPANEL WIDTHCOMPOSITECAPCOMPOSITECAP0.406"3.6"0.5"3.6"0.406"3.3"COMPOSITECAPCOMPOSITECAP5.55.5 5.5 Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.50SIDELITE PANELFULL LITELIP LITEBTS Full Lite Frame1515HORIZONTAL CROSS SECTIONLip Lite Glazing25VERTICAL CROSS SECTIONLip Lite GlazingG1BOTTOM RAIL(COMP.)INTERIOREXTERIORG2FIBERGLASS SKIN(0.070" THK.)FOAM CORE(POLYURETHANE -1.9 PCF MIN.)0.59"0.59"1.7"TOP RAIL(COMP.)G11.7"0.66"STILE (WOOD)G2INTERIOREXTERIOR13.938" MAX.PANEL WIDTH95.25" MAX. OVERALL PANEL HEIGHT 456.88" MAX.D.L.O. WIDTH79.06" MAX. D.L.O. HEIGHT15.25" (TYP.)2.625" (TYP.)2.625" (TYP.)11.875" MAX PANELWIDTH95.25" MAX PANEL HEIGHT79.125" MAX D.L.O. HEIGHT 7" MAX D.L.O.WIDTH STILE(WOOD)0.75"1.53"G41.71"O2535 TOP RAIL(WOOD)1.53"0.625"G4 BOTTOM RAIL (LVL)FIBERGLASS SKIN(0.080" THK.)0.625"INTERIOREXTERIORINTERIOREXTERIOR35HORIZONTAL CROSS SECTIONFlush Glazed45VERTICAL CROSS SECTIONFlush Glazed60SIDELITE PANELFULL LITEFLUSH GLAZEDZ:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.MODELMANUFACTURERHARDWARE TABLEKNOB: SIGNATURE SERIESKWIKSETDEADBOLT: SIGNATURE SERIES (980)KNOB: F51SCHLAGEDEADBOLT: B60HOPPE(THERMA TRU) MULTIPOINT : MPDGSB (3 pt. Manual Shootbolt) XXSEE HARDWARE CHARTXXXXSEE HARDWARE CHART67X11021031041059373811021031041051061038373859694748191718495729272867Fiber-Classic/Smooth-Star Door Panel OptionsProducts approved include all embossed and recessed panel doors.Similar glazed panel configurations are allowed.Panels shown are for illustration and are representative only.Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg 720272511© 2016 R.W. Building Consultants Inc.0.15" C-SINK(TYP)1-1/4" MIN.EMB. (TYP.)LCEB10.15" C-SINK(TYP)1-1/4" MIN.EMB. (TYP.)DLE5025SEE NOTE 1242329640LEXTERIORINTERIOR4142DEB71EXTERIORINTERIORC0.15" C-SINK (TYP) 1-1/4" MIN. EMB. (TYP.)LD1EXTERIORINTERIOR50CL0.15" C-SINK (TYP)EB1-1/4" MIN. EMB. (TYP.)D67HORIZONTAL CROSS SECTIONOutswing shown (Inswing similar)57HORIZONTAL CROSS SECTIONOutswing shown (Inswing similar)50242329625LSEE NOTE 11F0.15" C-SINK(TYP)4344454041424344454041424344454041424344454041424344451.15" MIN.EMB. (TYP.)CB25SEE NOTE 2Notes:1. Sidelite assembly screws located 7" from top and 14" from bottom & 2 more screws equally spaced between (4 screws total per side jamb).2. Sidelite assembly screws located 4" from each end (2 screws along head jamb).17HORIZONTAL CROSS SECTIONShown w/ 2X BuckOutswing shown (Inswing similar)27HORIZONTAL CROSS SECTIONShown w/ 2X BuckOutswing shown (Inswing similar)37VERTICAL CROSS SECTIONShown w/ 2X BuckOutswing shown (Inswing similar)47VERTICAL CROSS SECTIONShown w/ 2X BuckOutswing shown (Inswing similar)19464748464748464748464748606060Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.7138VERTICAL CROSS SECTIONShown w/ 1X sub-buck Outswing shown (Inswing similar)EXTERIORINTERIOREAC1-1/4" MIN. EMB. (TYP.)J148VERTICAL CROSS SECTIONShown w/ 1X sub-buck Outswing shown (Inswing similar)EXTERIORINTERIOREAC1-1/4" MIN. EMB. (TYP.)50JC18HORIZONTAL CROSS SECTIONShown w/ 1X sub-buckOutswing shown (Inswing similar)2423296EXTERIORINTERIORGE1-1/4" MIN.EMB. (TYP.)JA28HORIZONTAL CROSS SECTIONShown w/ 1X sub-buck Outswing shown (Inswing similar)AJC125SEE NOTE 11-1/4" MIN.EMB. (TYP.)E5040414243444540414243444525SEE NOTE 2Notes:1. Sidelite assembly screws located 7" from top and 14" from bottom & 2 more screws equally spaced between (4 screws total per side jamb).2. Sidelite assembly screws located 4" from each end (2 screws along head jamb).14647484647486060Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.19HORIZONTAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 4-9/16" jambDouble Door Only (N/A w/ Sidelites)1.25" MIN.2"INTERIOREXTERIOR1.5"MAX.CM1.5" MIN. 4"1.5" MAX.49HORIZONTAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 6-9/16" jambCEEM1-1/4" MIN.EMB. (TYP.)NINTERIOREXTERIORINTERIOREXTERIOR1-1/4" MIN.EMB. (TYP.)INTERIOREXTERIOR39VERTICAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 4-9/16" jambDouble Door Only (N/A w/ Sidelites) 59VERTICAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 6-9/16" jamb EPCC1.25"MIN.1.5"MAX.E1.5"MAX.1.5" MIN. 4.25"1.5" MAX.EC29HORIZONTAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 6-9/16" jamb INTERIOREXTERIOR43444550DINTERIOREXTERIOR69VERTICAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 6-9/16" jamb CE1.5"MAX.50SEE NOTE 225Notes:1. Sidelite assembly screws located 7" from top and 14" from bottom & 2 more screws equally spaced between (4 screws total per side jamb).2. Sidelite assembly screws located 4" from each end (2 screws along head jamb).111111404142434445404142434445404142434445404142D2" MIN.1-1/4" MIN. EMB. (TYP.)D2" MIN.1-1/4" MIN. EMB. (TYP.)SEE NOTE 1251-1/4" MIN.EMB. (TYP.)1-1/4" MIN.EMB. (TYP.)4647484647484647484647486060Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg EXTERIORINTERIOR75EXTERIORINTERIOR76E1-1/4" MIN. EMB. (TYP.)610VERTICAL CROSS SECTIONOutswing Sill1-1/4" MIN.EMB. (TYP.)510VERTICAL CROSS SECTIONInswing Sill505077DD© 2016 R.W. Building Consultants Inc.177EEEXTERIORINTERIOR838EXTERIORINTERIOR310VERTICAL CROSS SECTIONOutswing Sill110VERTICAL CROSS SECTIONInswing SillEEXTERIORINTERIOR1015410VERTICAL CROSS SECTIONPublic Access Sill163932SEE NOTE 1SEE NOTE 1EEXTERIORINTERIOR933210VERTICAL CROSS SECTIONInswing Sill34SEE NOTE 1SEE NOTE 21-1/4" MIN.EMB. (TYP.)IE1-1/4" MIN.EMB. (TYP.)D1-1/4" MIN.EMB. (TYP.)D1-1/4" MIN. EMB. (TYP.)D353637181716183334353637323839404142434445404142434445404142434445404142434445Notes:1. Sill Item #'s 17, 18, 32, 34, 35, 36, 37, 38 & 39 are attached to jambs w/ (3) #8 X 2-1/2" pfh screws at each end. Sill Item #'s 16 & 33 are attached to jambs w/ (2) #8 X 2-1/2" pfh screws at each end. Sill Item #15 is attached to jambs utilizing (2) #10 X 2" pph SMS at each end.2. Sidelite assembly screws located 4" from each end (2 screws along sill).25SEE NOTE 225SEE NOTE 24647484647484647484647486060Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.D8" (TYP.)4" (TYP.)4" (TYP.)4" (TYP.)D23" MAX. O.C. (TYP.)4" (TYP.)4" (TYP.)8" (TYP.)4" (TYP.)8" (TYP.)4" (TYP.) HEAD & JAMBS(TYP.) HEAD & JAMBS(TYP.)JAMBSXXOXXO2X BUCK ANCHORINGMASONRY(TYP.)2X BUCK(TYP.)ASTRAGALASTRAGAL15.5" MAX.O.C. (TYP.)2X BUCK(TYP.)MASONRY(TYP.)Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.1X BUCK2X BUCKLJ7" (TYP.)3" (TYP.)6" (TYP.)6" (TYP.)17.5" MAX.O.C. (TYP.)DSILL(TYP.)7" (TYP.)3" (TYP.)7" (TYP.)3" (TYP.)F1X BUCK2X BUCKLJ3" (TYP.)6" (TYP.)17.5" MAX. O.C. (TYP.)DSILL(TYP.) HEAD & JAMBS(TYP.) HEAD & JAMBS(TYP.)(TYP.)MASONRY(TYP.)FRAME(TYP.)XXOXXOFRAME ANCHORINGASTRAGALASTRAGALJAMBSSEE DETAIL 1(SHEET 12)SEE DETAIL 1(SHEET 12)SEE DETAIL 2(SHEET 12)SEE DETAIL 2(SHEET 12)JAMB TO HEAD DETAIL(TYP.)(3) #8 x 2-1/2"PFH WSDDIRECT TOMASONRY HEAD(TYP.) HEAD(TYP.)DIRECT TOMASONRYMNJAMBS(TYP.)DIRECT TOMASONRYNJAMBS(TYP.)PDIRECT TOMASONRYDBUCK(TYP.)BUCK(TYP.)FRAMEMASONRYOPENINGFRAMEMASONRYOPENING14.5" MAX. O.C. (TYP.) Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.282525LATCH & DEADBOLT DETAILSchlage / Kwikset27LATCH & DEADBOLT DETAILMultipoint Lock2530HINGE DETAIL2924232X BUCK1X BUCKDIRECT TOMASONRYLGM1/2" Ø HOLELATCH & DEADBOLT STRIKE DETAILSDETAIL 2OutswingAstragal Bolt Hole @ SillDETAIL 2InswingCoastal Astragal Strike Plate @ Sill8025GMDETAIL 1Coastal Astragal Strike Plate @ Head80GMULTIPOINT LOCK STRIKE DETAILSDETAIL 2InswingMultipoint Lock Strike Plate @ SillDETAIL 2OutswingMultipoint Lock Strike Plate @ SillDETAIL 1Multipoint Lock Strike Plate @ Head25GM78GG79791X BUCKDIRECT TOMASONRY2X BUCK1X BUCKDIRECT TOMASONRY2X BUCKDETAIL 2InswingStandard Astragal Strike Plate @ Sill8125GMDETAIL 1Standard Astragal Strike Plate @ Head81G1X BUCKDIRECT TOMASONRY2X BUCKASTRAGAL Multipoint LockSEE LATCH& DEADBOLTDETAILHINGE JAMBSEE HINGEDETAIL (TYP.)8.12" FROM TOP OF JAMB 25.5" (TYP.) BOOK DOOR 25.0" (TYP.) U1/HYBRID DOOR 11.125" FROM TOP OF JAMB 25.5" (TYP.) BOOK DOOR 25.5" (TYP.) U1/HYBRID DOOR 25.5" (TYP.) BOOK DOOR 25.0" (TYP.) U1/HYBRID DOORASTRAGAL Latch and Deadbolt5.5"SEE LATCH& DEADBOLTDETAIL60" (± 1.5") 60.375" (± 1.5") Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.3ABTS LITE FRAME1/2" & 9/16" GlazingG1GLAZING DETAILBTS Lite FrameDoor Panels & Sidelites1/2" - 9/16" THK. GLASS1/8" TEMPERED GLASS1/8" TEMPERED GLASSAIR SPACE1/2" GLASS BITE3A1.5"1.7" 1.7"1.5"3BBTS LITE FRAME1" Glazing0.56" 1"BACKBEDDINGCOMPOUND1" THK. GLASSAIR SPACE3BG2GLAZING DETAILBTS Lite FrameDoor Panels & Sidelites#10 X 1-1/2" PPH PLASCREW1/8" TEMPERED GLASS1/8" TEMPERED GLASS#10 X 1-1/2" PPH PLASCREW1/8" TEMPERED GLASSAIR SPACE1/8" TEMPERED GLASS5/8" THICK GLASS1/2" GLASS BITEG3GLAZING DETAILFlush GlazingDoor Panels1/2" GLASS BITEDURASEAL, ALUMINUMOR STEEL SPACERDURASEAL, ALUMINUMOR STEEL SPACERBACKBEDDINGCOMPOUNDBACKBEDDINGCOMPOUNDDURASEAL, ALUMINUMOR STEEL SPACER1" INSULATED GLASS INSERT OPTIONSINTERNAL GRID (GBG)INTERNAL GRID (GBG)(Optional Aluminum Spacer)MINI BLIND(Aluminum Spacer)DECORATIVE INSERTWROUGHT IRON INSERTPRIVACY INSERT5/8" INSULATED GLASS INSERT OPTIONSINTERNAL GRID (GBG)(Optional Aluminum Spacer)DOOR PANELPRIVACY INSERTINTERNAL GRID (GBG)9/16" INSULATED GLASS INSERT OPTIONSINTERNAL GRID (GBG)INTERNAL GRID (GBG)(Optional Aluminum Spacer)BTS Full Lite Frame3.25"(TYP.)6.437" (TYP.)6"(TYP.)21.13" MAXD.L.O. WIDTH79.13" MAX D.L.O. HEIGHT 9.75" (TYP.)#10 X 1-1/2"PPH PLASCREW5/8" INSULATED GLASS INSERT OPTIONSINTERNAL GRID (GBG)(Optional Aluminum Spacer)PRIVACY INSERTINTERNAL GRID (GBG)1/8" TEMPERED GLASSAIR SPACE1/8" TEMPERED GLASS3/4" THICK GLASS1/2" GLASS BITEG4GLAZING DETAILFlush GlazingSidelitesDURASEAL, ALUMINUMOR STEEL SPACERBACKBEDDINGCOMPOUNDSIDELITE PANELZ:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.2.13"0.68" 0.08"76SIDELITE SPACEROutswing2.14"0.08" 1.32" 0.99"2.18"1.5" 0.08"75SIDELITE SPACERInswing38INSWING THRESHOLDInswing Composite Adjustable Sill4.56"1.5"1WOOD JAMB4.56"0.75" 1.25"2.36"15PUBLIC ACCESS THRESHOLD6.0"0.5" 0.082"1.35"5.75"1.55"7.5"4.56"1.55"33INSWING THRESHOLDInswing Basic Fixed Sill34INSWING THRESHOLDInswing Moderate Climate Sill 1-3/8"39INSWING THRESHOLDInswing Basic Composite Adjustable Sill5.77"1.3"7.59"1.29"32INSWING THRESHOLDInswing Basic Composite Adjustable Sill 7-1/2"1.55"5.75"35INSWING THRESHOLDInswing Moderate Climate Sill5.75"1.55"36INSWING THRESHOLDInswing Basic Fixed 5-3/4" Sill37INSWING THRESHOLDInswing Basic Fixed 7-1/2" Sill16OUTSWING THRESHOLDComposite Sill1.5"5.83"4.56"1.01"17OUTSWING THRESHOLDComposite / Aluminum Sill5.75"1.01"18OUTSWING THRESHOLDComposite / Aluminum Sill(Thermal Break)0.45"1.79"1.92"0.91"2.06"0.68"8SWEEP9SWEEP10SWEEP77SIDELITE SPACERInswing Moderate Climate Threshold2.68"0.063"0.126"1.91"FLUSH BOLTFLUSH BOLTRETAINER20COASTAL ALUMINUM ASTRAGAL19STANDARD ALUMINUM ASTRAGAL0.063"2.68"1.91"FLUSHBOLTFLUSH BOLTRETAINERTHERMALBREAK0.063"Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg © 2016 R.W. Building Consultants Inc.BILL OF MATERIALSITEM #DESCRIPTIONMATERIALA1X BUCK (SG >= 0.42)WOODB2X BUCK (SG >= 0.42)WOODC1/4" MAX. SHIM SPACE-D1/4" X 2-3/4" PFH DeWALT OR ITW CONCRETE SCREWSTEELEMASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI301 OR HOLLOW BLOCK CONFORMING TO ASTM C90CONCRETEF#10 X 2" PFH WOOD SCREWSTEELG3/16" X 3-1/4" ITW CONCRETE SCREWSTEELI1/4" X 1-3/4" PFH DeWALT OR ITW CONCRETE SCREWSTEELJ1/4" X 3-3/4" PFH DeWALT OR ITW CONCRETE SCREWSTEELK#8 x 3" PFH WOOD SCREWSTEELL#10 X 2-1/2" PFH WOOD SCREW (1.15" MIN. EMBEDMENT)STEELM3/16" X 2-1/4" ITW CONCRETE SCREWSTEELN3/16" X 2-3/4" ITW CONCRETE SCREWSTEELP1/4" X 2-3/4" PFH DeWALT CONCRETE SCREWSTEELQ3/16" X 3-3/4" ITW CONCRETE SCREWSTEEL1JAMB (FINGER JOINT PINE )WOOD6WEATHERSTRIP (MEDIUM REACH)FOAM7WEATHERSTRIP (LONG REACH)FOAM8SWEEPVINYL9SWEEP (USE w/ MODERATE CLIMATE THRESHOLD)VINYL10SWEEP (USE w/ PUBLIC ACCESS THRESHOLD)VINYL11#10 X 1-3/4" PFH WOOD SCREWSTEEL15PUBLIC ACCESS THRESHOLDALUM16OUTSWING THRESHOLDALUM/COMP17OUTSWING THRESHOLDALUM/COMP18OUTSWING THRESHOLDALUM/COMP19STANDARD ALUMINUM ASTRAGALALUM20COASTAL ALUMINUM ASTRAGALALUM23#10 x 3/4" PFH WOOD SCREWSTEEL24#10 x 1" PFH WOOD SCREWSTEEL25#8 x 2-1/2" PFH WOOD SCREWSTEEL26#8 x 5/8" PFH WOOD SCREWSTEEL27LATCH STRIKE PLATESTEEL28DEADBOLT STRIKE PLATESTEEL294" X 4" HINGESTEEL32INSWING THRESHOLDALUM/COMP33INSWING THRESHOLDALUM/COMP34INSWING THRESHOLDALUM/COMP35INSWING THRESHOLDALUM/COMP36INSWING THRESHOLDALUM/COMP37INSWING THRESHOLDALUM/COMPBILL OF MATERIALSITEM #DESCRIPTIONMATERIAL38INSWING THRESHOLDALUM/COMP39INSWING THRESHOLDALUM/COMP40DOOR PANEL (BOOK)-41DOOR PANEL (HYBRID)-42DOOR PANEL (U1)-43FLUSH GLAZED DOOR PANEL (BOOK)-44FLUSH GLAZED DOOR PANEL (HYBRID)-45FLUSH GLAZED DOOR PANEL (U1)-463/4 FLUSH GLAZED DOOR PANEL (BOOK)-473/4 FLUSH GLAZED DOOR PANEL (HYBRID)-483/4 FLUSH GLAZED DOOR PANEL (U1)-50SIDELITE (FULL LITE)-61IVES #454 SURFACE BOLT (8" LONG)STEEL62SURFACE BOLT STRIKE PLATE (INSWING)STEEL63#10 x 2" PFH WOOD SCREWSTEEL64SURFACE BOLT STRIKE PLATE (OUTSWING)STEEL75SIDELITE SPACER (INSWING)PVC76SIDELITE SPACER (OUTSWING)PVC77SIDELITE SPACER (INSWING) - MODERATE CLIMATE SILLPVC78MULTIPOINT LOCK STRIKE PLATE @ HEADSTEEL79MULTIPOINT LOCK STRIKE PLATE @ SILLSTEEL80COASTAL ASTRAGAL STRIKE PLATESTEEL81STANDARD ASTRAGAL STRIKE PLATESTEELCONCRETE ANCHOR NOTES:Concrete anchor locations at the corners may be adjusted to maintain the min.edge distance to mortar joints.Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted tomaintain the min. edge distance to mortar joints, additional concrete anchorsmay be required to ensure the "MAX. ON CENTER" dimension are not exceeded.Concrete anchor table:2.1.1/4"MIN.EMBEDMENTANCHORSIZEMIN. CLEARANCETO ADJACENTANCHORMIN. CLEARANCETO MASONRYEDGEITWTAPCON1-1/4"2"4"ANCHORTYPE®3.1/4"DeWALT ULTRACON+1"4"®1-1/4"3/16"ITWTAPCON1-1/4"®AS SHOWN1-1/2"WOOD SCREW INSTALLATION NOTES:Maintain a minimum 5/8" edge distance, 1" end distance, & 1" o.c. spacing ofwood screws to prevent the splitting of wood.1.Z:\2023 FBC Drawings\Therma-Tru\FL-20461 R9\FL-20461.14-16.dwg