768 VECUNA RD SOLR23-0004 Solar Drawing_Rev-A 2-27-24PROJECT DATAGENERAL NOTESVICINITY MAPSHEET INDEXCODE REFERENCESPROJECTADDRESS768 VECUNA ROAD,ATLANTIC BEACH, FL 32233OWNER:ADAM MCQUISTONSCOPE:HOUSE PHOTOPHOTOVOLTAIC ROOF MOUNT SYSTEM36 MODULES-ROOF MOUNTED - 14.580 KW DC, 10.440 KW AC768 VECUNA ROAD, ATLANTIC BEACH, FL 32233DESIGNER:ESRREVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024G001COVER SHEETSIGNATURE14.580 KW DC ROOF MOUNTSOLAR PV SYSTEM WITH36 MITREX SOLAR M405-I3H 405W PVMODULES WITH36 ENPHASE IQ8PLUS-72-2-USMICROINVERTERSG001COVER SHEETE001SITE PLANS001ROOF PLAN AND MODULESE002ELECTRICAL PLANS002 STRUCTURAL DETAILE003ELECTRICAL LINE DIAGRAME004WIRING CALCULATIONSE005LABELSE006PLACARDPD001+ EQUIPMENT SPECIFICATIONSAUTHORITIES HAVING JURISDICTION:BUILDING: ATLANTIC BEACH CITYZONING: ATLANTIC BEACH CITYUTILITY: JEAPROJECT TO COMPLY WITH THE FOLLOWING:FLORIDA RESIDENTIAL CODE, 8TH EDITION 2023 (FRC)FLORIDA PLUMBING CODE, 8TH EDITION 2023 (FPC)FLORIDA BUILDING CODE, 8TH EDITION 2023 EDITION (FBC)FLORIDA MECHANICAL CODE, 8TH EDITION 2023 (FMC)2020 NATIONAL ELECTRICAL CODEFLORIDA FIRE PREVENTION CODE, 8TH EDITION 2023(FFPC)1.ALL COMPONENTS ARE UL LISTED AND NEC CERTIFIED, WHERE WARRANTED.2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 2020.3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION.4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR OTHERWISERUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY.5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION:SOLAR CIRCUIT" EVERY 10FT.6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 2020 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BEPROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICEENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED ATTHE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODECONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTINGGROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM.8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.9.PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRINGMUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE.11.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UVRESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.12.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE UL 1741 LISTED.13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BYQUALIFIED PERSONS [NEC 690.4(C)]14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES ANDSWITCHES.15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250.16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC690.1218.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT ORA MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)]19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.3120.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).21.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL170322.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.23.IN ACCORDANCE WITH 2021 IFC 1205.5, 2018 IFC 1204.4, AND 2015 IFC 605.11.2 A CLEAR, BRUSH-FREE AREA OF 10 FEET(3048 MM)SHALL BE REQUIRED FOR GROUND-MOUNTED PHOTOVOLTAIC ARRAYS.24. PANEL LAYOUT ORIENTATION IS SUBJECT TO CHANGE ON DESIGNED MOUNTING PLANES.25. ALL PERMANENTLY INSTALLED LUMINARIES, EXCLUDING THOSE IN KITCHEN APPLIANCES, SHALL HAVE AN EFFICIENCY OF AT LEAST45 LUMENS-PER-WATT OR SHALL UTILIZE LAMPS WITH AN EFFICIENCY OF NOT LESS THAN 65 LUMENS-PER-WATT.26. MOUNTING SYSTEMS SHALL BE LISTED AND LABELLED IN ACCORDANCE WITH UL 2703 TO BE INSTALLED IN ACCORDANCE WITH THEMANUFACTURER’S INSTALLATION INSTRUCTIONS AND THEIR LISTINGS. 102'-0"83'-0"103'-0"83'-0"UM LC ACD MSP CB1SITE PLANSCALE: 1/16" = 1'-0"E001REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024PROJECT DESCRIPTION:SITE PLANNOTE: VISIBLE, LOCKABLE, LABELED AC DISCONNECTLOCATED WITHIN 10' OF UTILITY METER36 X MITREX SOLAR M405-I3H 405W MONO MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESDC SYSTEM SIZE: 36 x 405 = 14.580KW DCAC SYSTEM SIZE: 36 x 290 = 10.440KW ACE001ROOF ARRAY AREA #1:- 62.97 SQ FT.ROOF ARRAY AREA #2:- 167.92 SQ FT.ROOF ARRAY AREA #3:- 230.89 SQ FT.ROOF ARRAY AREA #4:- 293.86 SQ FT.ROOF ARRAY AREA #1:- 62.97 SQ FT.ROOF ARRAY AREA #2:- 167.92 SQ FT.ROOF ARRAY AREA #3:- 230.89 SQ FT.ROOF ARRAY AREA #4:- 293.86 SQ FT.EQUIPMENT SUMMARY36 MITREX SOLAR M405-I3H 405W MONO MODULES36 ENPHASE IQ8PLUS-72-2-US MICROINVERTERSROOF #1(3) MITREX SOLAR M405-I3H 405WMONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #2(8) MITREX SOLAR M405-I3H405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #3(11) MITREX SOLAR M405-I3H 405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #4(14) MITREX SOLAR M405-I3H405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERS(N) ENPHASE COMBINER BOX(E) MAIN SERVICE PANEL (INSIDE)(N) VISIBLE, LOCKABLE,LABELED NON-FUSED AC DISCONNECT(LOCATED WITHIN 10' OF UTILITY METER)(E) UTILITY METERVECUNA ROADPROPERTY LINEPROPERTY LINE PROPERTY LINEPROPERTY LINE (E) POOLEXISTINGDRIVEWAY1-STORYHOUSEROOF ACCESS POINT(E) TREES(E) FENCE(E) GATE (TYP.)(E) DETACHED STRUCTURE (TYP.)(N) LOAD CENTER (INSIDE)AAAAAA 8'-4"11'-3"8'-6"10"MSP 3'-0" 30'-0" 18'-0" 4'-0" 1'-3" 3" 6" 6"8'-10"21'-7"7"1'-4"MODULE TYPE, DIMENSIONS & WEIGHTSCALE: 3/32" = 1'-0"ROOF PLAN ANDMODULESNUMBER OF MODULES = 36 MODULESMODULE TYPE = MITREX SOLAR M405-I3H 405W MONO MODULESMODULE WEIGHT = 45.2 LBS / 20.5KG.MODULE DIMENSIONS = 67.8" x 44.6" = 20.99 SFMITREX SOLARM405-I3H 405WMODULES67.8"44.6"S001REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024ARRAY AREA & ROOF AREA CALC'STOTAL PV ARRAYAREA(SQ. FT.)TOTAL ROOFAREA(Sq. Ft.)ROOFAREA COVERED BYARRAY (%)755.642515.7330ROOF DESCRIPTIONROOF TYPEASPHALT SHINGLEROOF# OFMODULESROOFPITCHAZIMUTHTRUSSSIZETRUSSSPACING#1317°275°2"X4"24"#2817°185°2"X4"24"#31117°275°2"X4"24"#41417°95°2"X4"24"1ROOF PLAN AND MODULESS001MSP- MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT- TRUSSLEGEND(E) MAIN SERVICE PANEL(INSIDE)ROOF #1(3) MITREX SOLAR M405-I3H 405WMONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #1PITCH - 17°AZIM. - 275°ROOF #2(8) MITREX SOLAR M405-I3H405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #2PITCH - 17°AZIM. - 185°ROOF #3(11) MITREX SOLAR M405-I3H 405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #3PITCH - 17°AZIM. - 275°ROOF #4(14) MITREX SOLAR M405-I3H405W MONO MODULES WITH ENPHASEIQ8PLUS-72-2-US MICROINVERTERSROOF #4PITCH - 17°AZIM. - 95°ACTUAL MAXIMUM CANTILEVER ALLOWED = L/3,WHERE L IS THE ATTACHMENT SPACINGATTACHMENT SPACING, L = 48"ACTUAL MAXIMUM CANTILEVER ALLOWED = 48/3ACTUAL MAXIMUM CANTILEVER ALLOWED = 16",i.e, 1'-4"CANTILEVER LENGTH 10"CANTILEVER LENGTH 6"CANTILEVER LENGTH 1'-3''ROOF ACCESS POINT(95) EVEREST K2 SYSTEMS SPLICE FOOT XLATTACHMENTS18" FIRE SETBACK18" FIRE SETBACK18" FIRE SETBACK18" FIRE SETBAC K 36" FIRE SETBACK18" FIRE SETBACK 18" FIRE SETBACK 36" FIRE SETBACK36" FIRE SETBACK18" FIRE SETBACK 18" FIRE SETBACK CANTILEVER LENGTH 7''CANTILEVER LENGTH 1'-4''CANTILEVER LENGTH 6''CANTILEVER LENGTH 3"AA(N) EVEREST K2 SYSTEMSCROSSRAIL 44-X RAIL UM LCACDMSPCB SDSDSDSDSCALE: 1/8" = 1'-0"ELECTRICAL PLANREVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024E002BILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONSOLAR PV MODULES36MITREX SOLAR M405-I3H 405W MODULEMICRO INVERTERS36ENPHASE IQ8PLUS-72-2-US MICROINVERTERSSOLADECK4SOLADECKSRAIL20EVEREST K2 SYSTEMS CROSSRAIL 44-X RAILSPLICES4SPLICESMID MODULE CLAMPS50MID MODULE CLAMPSEND CLAMPS44END CLAMPS / STOPPER SLEEVEATTACHMENTS95EVEREST K2 SYSTEMS SPLICE FOOT XLATTACHMENTSCIRCUIT #1CIRCUIT #2CIRCUIT #3CIRCUIT LEGENDSUMMSP- UTILITY METER- MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT- CONDUITACD- AC DISCONNECTLEGEND- COMBINER BOXCBLC- LOAD CENTER- SOLADECKSD- TRUSS1ELECTRICAL PLANE002NOTE : CONDUIT INSTALLED ATMINIMUM DISTANCE OF 7/8 INCHESABOVE ROOF(N) ENPHASE COMBINER BOX(E) MAIN SERVICE PANEL(INSIDE)(N) VISIBLE, LOCKABLE,LABELED NON-FUSED AC DISCONNECT(LOCATED WITHIN 10' OF UTILITY METER)(E) UTILITY METERCIRCUIT #1(13 MODULES)CIRCUIT #2(12 MODULES)CIRCUIT #3(11 MODULES)(36) ENPHASEIQ8PLUS-72-2-US MICROINVERTERSLOCATED UNDER EACH PANEL (240V)VECUNA ROAD(N) CONDUIT(N) SOLADECK (TYP.)(N) LOAD CENTER (INSIDE)AAAAA REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024STRUCTURAL DETAILS0022ATTACHMENT DETAIL (ENLARGED VIEW)S0021ATTACHMENT DETAIL (SIDE VIEW)S002SCALE: N.T.S.SCALE: N.T.S.SEE (2/S002) FORENLARGED VIEWPV MODULE(E) ASPHALT SHINGLE ROOF2"X4" TRUSS @ 24" O.C.6"CHANNEL NUTPV MODULEGROUNDINGEND/MID CLAMPEVEREST K2 SYSTEMSCROSSRAIL 44-X RAIL(E) ASPHALT SHINGLE ROOF2"X4" TRUSS @ 24" O.C.M5 X 60MM DIN 571, METRIC, HEXHEAD LAG SCREW BOLTS, A2STAINLESS STEEL WITH MIN. 2"PENETRATION INTO SUPPORT(N) EVEREST K2 SYSTEMSSPLICE FOOT XL ATTACHMENTS(E) ROOF DECKING(E) ROOF DECKING L1L2NG3L1L2G-+-+2-+13=12====BRANCHTERMINATOR(ET-TERM)GN-+-+2-+13=====-+-+2-+13=====SOLADECK,600V, NEMA 3R,UL LISTEDBRANCH #1BRANCH #2BRANCH #3L2L2L1L2L120A/2P20A/2P20A/2P12131112101115A/2P(36) MITREX SOLAR M405-I3H405W MODULESENPHASE IQ8PLUS-72-2-USMICROINVERTERSLOCATED UNDER EACH PANEL (240V)IQGATEWAYENPHASE IQ COMBINERX-IQ-AM1-240-4/4C 120/240VAC,1ɸ, 3W 125A RATED BUS BAR,NEMA 3R SOLAR LOADS ONLYUL 1741 COMPLIANTLOADLINEGNVISIBLE, LOCKABLE,LABELED AC DISCONNECTLOCATED WITHIN 10'OF UTILITY METER(E) MAIN BREAKER TOHOUSE 240 V, 200A/2PLINE SIDEINTERCONNECTIONAT MAIN PANELPER ART. 705.11NL2L1MTO UTILITY GRIDGNGECGNBI-DIRECTIONALUTILITY METER120/240V, 1ɸ, 3-WEXISTING GROUNDINGELECTRODE SYSTEM TOEARTH REF. NEC 250.52,250.53(A)(E) MAIN SERVICEPANEL,SQUARE D 200A RATED, 240V(E) BONDING JUMPERPER NEC 250.92(A)(2)#4 AWG CU, MAINBONDING JUMPERPER NEC 250.8 &250.28(N) LOAD CENTER70A RATEDL1L24N(N)60A/2PSUPPLY SIDE CONNECTIONREF 2020 NEC 230.82(6)/705.11GNGL1L23NGPV ACDISCONNECT240V, 1ɸ, 3W60A RATEDNEMA 3RREVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024ELECTRICAL LINE DIAGRAMSCALE: NTSE003DC SYSTEM SIZE: 36 x 405 = 14.580KW DCAC SYSTEM SIZE: 36 x 290 = 10.440KW AC(36) MITREX SOLAR M405-I3H 405W MONO MODULESWITH (36) ENPHASE IQ8PLUS-72-2-US MICROINVERTERSLOCATED UNDER EACH PANEL (240V)(1) BRANCH CIRCUIT OF 13 MODULES;(1) BRANCH CIRCUIT OF 12 MODULES; AND(1) BRANCH CIRCUIT OF 11 MODULES ARE CONNECTED IN PARALLEL1ELECTRICAL LINE DIAGRAME003QTYCONDUCTOR INFORMATIONCONDUIT TYPECONDUITSIZE(6)CU#12AWG -ENPHASE ENGAGE CABLE(L1 & L2 NO NEUTRAL)N/AN/A(1)(6)CU#10AWG -ENT OR LFMC IN ATTIC3/4"(1)CU,THWN-2 GND(2)EMT, LFMC OR PVC(1)CU,THWN-2 OR THHN N(1)CU,THWN-2 OR THHN GND(3)EMT, LFMC OR PVC(1)12343/4"3/4"THWN-2 OR THHN L1,L2 & NTHWN-2 OR THHN L1 &L2THWN-2 L1 &L2CU #10AWG -CU #6AWG -CU #6AWG -CU #10AWG -CU #6AWG -CU #6AWG -CU #6AWG -BARE COPPER IN FREE AIR#12/2 ROMEX INATTICNOTE : "CONDUIT SIZE IS MINIMUM REQUIRED PER NEC300.17. CONTRACTOR MAY UPSIZE AS NEEDED".OCPD CONDUCTOR SIZEBREAKER/FUSE SIZEWIRE GAUGE SIZE (75°C,COPPER)20A10 AWG25A10 AWG30A10 AWG35A8 AWG40A8 AWG45A8 AWG50A8 AWG60A6 AWG70A4 AWG80A4 AWG90A3 AWG100A3 AWG110A2 AWG125A1 AWG150A1/0 AWG175A2/0 AWG200A3/0 AWGINTERCONNECTION NOTES:1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCEDETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.59].2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9],[NEC 230.95].3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THEBUSBAR RELATIVE TO THE MAIN BREAKER.DISCONNECT NOTES:1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHENTHE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARECONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLYTHE UPPER TERMINALS)2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITYPERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH3. DISCONNECT MEANS AND THEIR LOCATION SHALL BE INACCORDANCE WITH [NEC 225.31] AND [NEC 225.32].GROUNDING & GENERAL NOTES:1. GROUNDING ELECTRODES AND GROUNDING ELECTRODE CONDUCTORS.ADDITIONAL GROUNDING ELECTRODES SHALL BE PERMITTED TO BEINSTALLED IN ACCORDANCE WITH 250.52 AND 250.54.GROUNDING ELECTRODESSHALL BE PERMITTED TO BE CONNECTED DIRECTLY TO THE PV MODULEFRAME(S) OR SUPPORT STRUCTURE PER [NEC 690.47(B)]2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE.3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTINGELECTRODE4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT ISFOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINALINSPECTION.5. SOLADECK QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THEFIELD - SOLADECKS DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRETYPE TRANSITIONS.6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHERAC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BEINSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS.8. ALL NEW SERVICE INSTALLATIONS AND REPLACEMENTS REQUIRE ASURGE-PROTECTIVE DEVICE (SPD) IN ACCORDANCE WITH [NEC 230.67]. THESPD SHALL BE TYPE 1 OR TYPE 2 AND IS REQUIRED TO BE AN INTEGRAL PART OFTHE SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO.RACKING NOTE:1.BOND EVERY OTHER RAIL WITH #6 BARE COPPERCU,THWN-2 OR THHN GNDAA REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024WIRING CALCULATIONSE004PERCENT OFVALUESNUMBER OF CURRENTCARRYING CONDUCTORS IN EMT.804-6.707-9.5010-20SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #MITREX SOLAR M405-I3H 405W MODULE VMP31.11V IMP13.02A VOC37.55V ISC13.73A TEMP. COEFF. VOC-0.26%/°C MODULE DIMENSION67.8"L x 44.6"W x 1.2"D (In Inch)AMBIENT TEMPERATURE SPECSRECORD LOW TEMP-4°AMBIENT TEMP (HIGH TEMP 2%)36°MODULE TEMPERATURE COEFFICIENT OF Voc-0.26%/°CELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT.3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSEAS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARYOUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS.6.WHERE SIZES OF SOLADECKS, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THEGROUNDING CLIP MANUFACTURER'S INSTRUCTION.9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.10.TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THESOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C.11.CONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(C)INVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ8PLUS-72-2-US MICROINVERTERSMIN/MAX DC VOLT RATING30V MIN/ 58V MAXMAX INPUT POWER235W-440WNOMINAL AC VOLTAGE RATING240V/ 211-264VMAX AC CURRENT1.21AMAX MODULES PER CIRCUIT13 (SINGLE PHASE)MAX OUTPUT POWER290 VAA REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024LABELSE005LABEL-1:CAUTION:AUTHORIZED SOLARPERSONNEL ONLY!LABEL LOCATION:AC DISCONNECTWARNING!TERMINALS ON THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITIONELECTRICAL SHOCK HAZARDLABEL LOCATION:AC DISCONNECTCOMBINERMAIN SERVICE PANELSUBPANELMAIN SERVICE DISCONNECTCODE REF: NEC 690.13(B)LABEL- 2:!WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:UTILITY METERMAIN SERVICE PANELSUBPANELCODE REF: NEC 705.12(C) & NEC 690.59LABEL- 3:TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNING!LABEL LOCATION:MAIN SERVICE PANELSUBPANELMAIN SERVICE DISCONNECTCOMBINERCODE REF: NEC 110.27(C) & OSHA 1910.145 (f) (7)LABEL- 4:LABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 705.12(B)(3-4) & NEC 690.59LABEL- 5:CAUTION!PHOTOVOLTAIC SYSTEM CIRCUIT ISBACKFEEDLABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 705.12(B)(3)(2)LABEL- 6:SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELSRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECTCODE REF: NEC 690.56(C)(2)LABEL- 8:PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTCODE REF: NEC 690.13(B)LABEL- 9:LABEL- 10:LABEL LOCATION:MAIN SERVICE PANELSUBPANELAC DISCONNECTCODE REF: NEC 690.54RATED AC OUTPUT CURRENTPHOTOVOLTAICAC DISCONNECTNOMINAL OPERATING AC VOLATGE240 VWARNING!POWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICEMAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS PRESENT)CODE REF: NEC 690.13(B)LABEL- 11:43.56 ALABEL LOCATION:AC DISCONNECTCODE REF: FFPC 11.12.1.1.1.1 & NEC 690.56(C)THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVINGA MINIMUM HEIGHT OF 3/8 IN. (9.5 MM), IN WHITE ON A RED BACKGROUND.TURN RAPID SHUTDOWNSWITCH TO THE 'OFF'POSITION TO SHUTDOWNENTIRE PV SYSTEMEMERGENCY RESPONDER:THIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRIC PV PANELSLABEL LOCATION:AC DISCONNECTCODE REF:NFPA 1 (11.12.2.1.1.1.1)1.THE RAPID SHUTDOWN LABEL SHALL BE LOCATED ON OR NO MORETHAN 3 FT (1 M) FROM THE SERVICE DISCONNECTING MEANS2.(HEIGHT OF LABEL IS 3/8 IN. (9.5 MM), IN WHITE ON A RED BACKGROUND)LABEL- 12:EMERGENCY CONTACTSUNERGY SOLAR LLC(727)375-9375LABEL- 14LABEL LOCATION:MAIN SERVICE DISCONNECTCODE REF: NFPA 1 (11.12.2.1.5)LABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 705.12(B)(3)(2)LABEL- 7:WARNING!THIS EQUIPMENT FED BYMULTIPLE SOURCES. TOTALRATING OF ALL OVERCURRENTDEVICES EXCLUDING MAINSUPPLY OVERCURRENT DEVICESHALL NOT EXCEED AMPACITYOF BUSBAR.LABEL- 13 UM LC ACD MSP CB SDSDSDSD REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024PLACARDE006LABELING NOTES:1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACTREQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS.2. LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535.3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21]5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLYAFFIXED FFPC 11.12.2.1.1.2768 VECUNA ROAD, ATLANTIC BEACH, FL 32233MULTIPLE SOURCES OF POWERCAUTION:DIRECTORYPERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THESERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM.(ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:NEC 690.56(B)&(C), [NEC 705.10])PER FFPC 11.12.2.1.4(N) SOLADECK (TYP.)(N) PV ARRAY(N) ENPHASE COMBINERBOX(N) PV AC DISCONNECT(E) MAIN SERVICE PANEL(INSIDE)(E) UTILITY METER(N) LOAD CENTER (INSIDE)AA REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024MODULEDATASHEETPD001 REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024MICROINVERTERDATASHEETPD002 REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024COMBINER BOXDATASHEETPD003 REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024ATTACHMENTDATASHEETPD004 REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024DATASHEETPD005RACKING REVSHEET NAMESHEET SIZESHEET NUMBERADAM MCQUISTON RESIDENCE 768 VECUNA ROAD, ATLANTIC BEACH, FL 32233ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESR09/14/2023INITIAL DESIGNSUNERGY SOLAR LLC7625 LITTLE RD. SUITE 200A,NEW PORT RICHEY, FL 34654AREVISION01/25/2024SOLADECKDATASHEETPD006