321 8th St RESO24-0023 REVISION 3-19-24 Revision Request/Correction to Comments *ALL INFORMATION
S1 HIGHLIGHTED IN
City of Atlantic Beach Building Department GRAY IS REQUIRED.
Oar 800 Seminole Rd, Atlantic Beach, FL 32233 2
n'� Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: R 5 r� .OOZ3
❑ Revision to Issued Permit OR Corrections to Comments Date: .?i1/r/2e,Z.
Project Address: 30 ae*4 ST re t
Contractor/Contact Name: %` / t yen 12/4 /
Contact Phone: • Email: ii),(/4/(---/Lcy-a'ki/t)714'4 ei\Vj
Description of Proposed Revision/Corrections: /'
/ 1,-/' / t
1-1:;&
i t
lit/ A ‘'AA/ affirm the revision/correction to comments is inclusive of the proposed changes.
(Printed name)
• Will proposed revision/corrections add additional square footage to original submittal?
No ❑ Yes (additional s.f. to be added:
Wil proposed revision/corrections add additional increase in building value to original submittal?
No ❑*Yes(additional increase in building value: $ ) (Contractor must sign if increase in valuation)
*Signature of Contractor/Agent:
(Office Use Only)
❑ Approved ❑ Denied — Not Applicable to Department Permit Fee Due $
Revision/Plan Review Comments
Department Review Required:
Building
Planning&Zoning Reviewed By
Tree Administrator
Public Works
Public Utilities
Public Safety Date
Fire Services Updated 10/17/18
/?e5oz'/--O42- 3 r
GLOBAL ! . TURF , 4-
ti
GREENING PLANET EARTH
.4 44
----- ----._ � ,1 . '
Product Specification Sheet R -, fce ate ' ; ,�
4' , ket^
Pro Putt-44 .
s . O. iiik
0o USES r SPECIFICATIONS
► Putting Green Pile Height: 5/8"
► Driving Ranges Turf Gauge: 3/16
Face Weight: 44 oz./yd2
► Bocce Ball Backing Weight: 23 oz./yd2
► Tennis Court Total Weight: 67 oz./yd2
0. Landscape Stitch Rate: 31/10cm
Stitches/M2: 65100
► Medium-Heavy Traffic Material/Dtex: PP5800
Color: Medium Bi-Color Green
Type Of Fiber: Polypropylene Monofilament
O15 Year Manufacturer's Warranty Infill Amount: 1.0 lb./psf.
8 Year Manufacturer's High Traffic Warranty Primary Backing: Premium GST Backing
tes Flo-Rite Drainage Technology Tuft Bind: 8+ lb/force (ASTM D1335)
Permeability: 71.0 inches/hr. (ASTM F1551)
Melting Point: 176 °F (ASTM D2859)
Grab Tear MD: >300 lb./force (ASTM D5034)
GST Grass -- Grab Tear CMD: >200 lb./force (ASTM D5034)
Roll Width: 15 ft
8
Roll Length: 100 ft
a`0,„„ r 1;4' °r , . '' :�< Sq. Ft. Per Roll: 1500
I-IX Decomposed°Mit* ;'. ,. V i
ort wuRoodBaw - : ,f .
Total Roll Weight: 686 lbs
li
2-2K ease Rock
KIK Mesh•
I!phone
IAD
5960 Inglewood Drive, Ste.150, Pleasanton, 94588, USA
Telephone: 510-732-2300 Fax: 510-732-6188 I Toll Free: 877-SYN-TURF (796-8873)
II www.globalsynturf.corn I Email: info@globalsynturf.com
/ 557 (71' /)()z5
Mir:Lf
TESTING SERVICES
INC:
TEST REPORT
CLIENT:
Company: Global Syn-Turf Report Number: 67993B
Address: 2482 Technology Drive Lab Test Number: 2836-9370
Hayward,CA 94545 Test Completion Date: 7/11/2016
Report Date: 7/20/2016
Page: 1 of 1
Requested By: Andrew Gao
TEST MATERIAL:
Material Type: Synthetic Turf Date Received: 7/7/2016
Material Condition: EXCELLENT: XXX GOOD: POOR: REJECTED:
Turf ID: Pro Putt-44
TESTING METHODS REQUESTED:
Testing Services Inc.was instructed by the client to test for the following...
Standard: ASTM F1551 Test Method: Standard Test Methods for Comprehensive Characterization of Synthetic Turf Playing
Surfaces and Materials:Suffix-DIN 18-035, Part 6:Water Permeability of Synthetic Turf
Systems and Permeable Bases
SAMPLING PLAN:
Sampling Date: 717/2016
• Specimen sampling is performed in the sampling department at TSI.
• The sampling size of specimens is determined by the test method requirements.
• In the event a specific sampling size is not called for,a determination will be made based on previous testing experience,and approved for use by an authorized
manager.
• All samples are subjected to the outside environmental conditions of temperature and relative humidly.
• Sample requiring pre-determined exposure to specified environmental conditions based on a specific test method,take place in the departments in which they are tested
DEVIATION FROM TEST METHOD:
State reason for any Deviation from,Additions to,or Exclusions From Test Method.
none
TEST SUMMARY:
TEST METHOD TEST DESCRIPTION TEST RESULT
ASTM F1551;Suffix-DIN 18-035, Part 6 Average Rainfall Capacity(Water Permeability) 71.0 inches/hour
*Test data values represent drainage rates for the turf and infill only,and do not take into account the percolation properties of a sub-base or padding.
Infill System:1.2 lbs/ft2Silica Sand #of Specimens(3)11.5"Diameter
Tube:10.75"OD 10.00"ID 8"Length(Beveled) Tube Index Mark: 6" Tube Weight: 39 lbs
Flange: 9.375"Diameter Tube Flow Head: 2 Gallons Pre-Conditioning:none
We undertake all assignments for our clients on a best effort basis.Our findings and judgments are based on the information to us using the latest test methods available.
TSI can only ensure the test results for the specific items tested.
Unless otherwise noted in the deviations sections of this report,all tests performed are in compliance with stated test method.
Test Report Approval:
Erle Miles,Jr.VP,Testing Services Inc
TSi Accreditation: Our laboratory is accredited by the US Dept of Commerce,National Institute of Standards and Technology:ISO/IEC 17025:2005.Our code#is:
NVLAP 100108-0.TSi is a certified independent testing laboratory by the Synthetic Turf Council
Form: Rev: Revision Date: Page 1 of 1
Release Date: Control Type: Electronic—Expires 24 hours after this date:Jul. 21, 16
Printed copies are uncontrolled
OUR LETTERS AND REPORTS APPLY ONLY TO THE SAMPLE TESTED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY PO Box 2041
IDENTICAL OR SIMILAR PRODUCTS. THESE LETTERS AND REPORTS ARE FOR THE USE ONLY OF THE CLIENT TO WHOM THEY ARE ADDRESSED AND Dalton, GA 30722-2041
THEIR COMMUNICATION TO ANY OTHERS OR THE USE OF THE NAME TESTING SERVICES,INC. MUST RECEIVE OUR PRIOR WRITTEN APPROVAL. 706 226-1400
OUR REPORTS,LETTERS,NAME,SEALS,OR INSIGNIA ARE NOT UNDER ANY CIRCUMSTANCES TO BE USED IN ADVERTISING TO THE GENERAL PUBLIC.