Loading...
172 Poinsettia Street ROOF24-0015 PermitOWNER:ADDRESS:CITY:STATE:ZIP: HUBBARD LETITIA 172 POINSETTIA ST ATLANTIC BEACH FL 32233-4018 COMPANY:ADDRESS:CITY:STATE:ZIP: ROMANO BROTHERS ROOFING, INC 155 E Levy Rd ATLANTIC BEACH FL 32233 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170638 0080 SALTAIR SEC 03 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 172 POINSETTIA ST ROOF NON SHINGLE TOURCHDOWN ROOF $5490.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING NOTICE OF COMMENCEMENT INFORMATIONAL Notes: No inspections may be scheduled until a copy a recorded Notice of Commencement has been submitted to the Building Department 2 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In- Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/19/2024 PERMIT NUMBER ROOF24-0015 ISSUED: 3/19/2024 EXPIRES: 9/15/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $80.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $124.00 2 of 2Issued Date: 3/19/2024 PERMIT NUMBER ROOF24-0015 ISSUED: 3/19/2024 EXPIRES: 9/15/2024 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: ____________________________________________________ Permit No. ___________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION _____________________________________________________ Permit Type DESCRIPTION ACCOUNT QTY PAID PermitTRAK $124.00 ROOF24-0015 Address: 172 POINSETTIA ST APN: 170638 0080 $124.00 BUILDING $80.00 BUILDING PERMIT 455-0000-322-1000 0 $80.00 BUILDING PLAN REVIEW $40.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R26492 $124.00 Printed: Tuesday, March 19, 2024 11:13 AM Date Paid: Tuesday, March 19, 2024 Paid By: ROMANO BROTHERS ROOFING, INC Pay Method: CREDIT CARD 10157940350 1 of 1 Cashier: AG Cash Register Receipt City of Atlantic Beach Receipt Number R26492 S' BUILDING PERMIT APPLICATION'' FORINTERILOFFICEUSEONLY City of Atlantic Beach Building Department PERMIT# KUOF Z4- b b 800 Seminole Road, Atlantic Beach, FL 32233 ALL information required to processn'''':/ Phone: (904) 247-526 Email: Buildin -Det coab.us Job Address t 'la, ePoir t, S RE# Legal Description IQ• 11, t u,.QS, act E Sp,1 .6, Lc. 1,3 -.a.2 c„C 1 6 2,(4 4 of Work(Replacement Cost) iSLI q b Heated/Cooled SF Non-Heated/Cooled SF Class of Work: New Addition *Iteration Repair Move Demo Pool Window/Door C •Use of existing/proposed structure(s): Commercial Residential • If existing structure, is a fire sprinkler system installed?:Yes No RI •Will tree(s)be removed in association with proposed proje ? Yes (Must submit separate Tree Removal Permit) No U Describe in detail the type of work to be performed: U 5 s dikrDrc t•,cS0.,a^ Florida Product Approval# r V SG ED. t For multiple products use Product Approval Information Sheet) Property Owner Information Name `t,t;-i 0,, t4, t 0 66/AA Phone q t.*q R q Vp'2 3`7 Address ( L f Q }',5e tcc C)+s City ( -1-)Ayfi' G 1 -QC'i1 State r Zip 3222..3 3 S '(.-"Email ,l• y .( iA I0 {4li)meepcai or Agent(If Agent, Power of Attorney or Agency Letter Required) s Contractor Information Name of Company ROMANO BROTHERS ROOFING INC. Phone 904-571-6142V) lc Address 400 LEVY ROAD City ATLANTICBEACH State FL Zip 32233 Qualifying Agent DANIEL ROMANO State Certification/Registration# CCC1328893 Email ROMANOBROTHERSROOFING@GMAIL.COM Job Site Contact Number DANIEL 904-610-0476 Worker's Compensation Insurer WBS OR Exempt Expiration Date 12/31/24 Architect's Name Email Phone Engineer's Name Email Phone Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. I+I In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this city/county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE SITE OF THE IMPROVEMENT BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE MENCEMENT. ki.1.-e.-4.)--W;;11/4/4-A/1-< 1 of Owner or R nSignatureget) Signature of Contractor) Signed and sworn to(or affirmed) before me this day of Signed and sworn to(or affirmed)bef e me this 5 day of 01\4C L ,Z24. by Lai-i-(-Ic, II. (4,16r I plAl 26)2`4 by to 1 VQ Atc-kKO Signature of Notary .401/— Signature of Notary Personally Known OR Produced Identification c rsonally Known OR [ ] Produced Identification LTypeofIdentification* Type of Identification: i 03F.,,....sf.., NICHOLASJOSHUA B JOSHUA BIIOWER NotaryPublic•Stareof Florida' Notdf 2;4Yi NICHOLAS JOSHUA BROWER y ubhc Sta[eof Flory s`` Commission HH 186068inf;' Notary Public-State of FloridaM C°mmission HH 186068oFn My Comm.Expires Feb 1,20267 P Commission 4 HH 186068Y Comm.Expires Feb 1,2026 Bonded through National Notary Assn.eci FL ` My rnmm Cvn:.....r_,.. .,..,. Bonded through Nalinn,i u_.__.. NOTICE OF COMMENCEMENT State of FLORIDA 1Th 1 i1TaxFolioNo. o T), CO Ulm County of VV C. To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in thi NOTIC OF COMMENCEMENT. Legal Description of property being improved: 10 • 1 Lo • S• D..4 t it.n 3M 6-D--1--t. o L 10 1, Address of property being improved: 1 r. ,t Q- ,I e \•. 3 33 General description of improvements: REROOF Owner: (e )+1(L •N • H lel 4 rettr Address: 2— , l I, • (`i rt Owner's interest in site of the improvement: Fee Simple Titleholder(if other than owner): Name: Contractor: ROMANO BROTHERS ROOFING INC. Address: PO BOX 330337 ATLANTIC BEACH FL 32233 Telephone No.: (904)246-5649Fax No: (904)246-4810 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: DANIEL ROMANO Address: 400 LEVY RD,ATLANTIC BEACH FL 32233 Telephone No: (904)610-0476 Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b), Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Doc#2024049932,OR BK 20977 Page 491, Signed: l T.,..‹)7,(.11_,,i Date: 31q11' Number Pages:1 Before me this day of ArF in the Countylof Duval,State Recorded 03/13/2024 10:35 AM, Of Florida,has personally appeared 4-e-,i if)0, 1-/ cy OOii f0( JODY PHILLIPS CLERK CIRCUIT COURT DUVAL Notary Public at Large,State of Florida,County of Duval. COUNTY My commission expires: (')2-a I-3 4 — — —--— — —— — — — RECORDING $10 00 Personally Known: p I ""r o, NICHOLAS JOSHUA BROWER O Identification: 1 : Notary Public-State of Florida i,4 Commission 4 HH 1860681 ''.!'orc'. My Comm.Expires Feb 1,2026 F I Borded through National Notary Assn. r fes- i RN 'mrd'`ERD TABLE IA: WOOD DECKS—NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER al SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVERRoofDeckaseInsulation Layer Type FastenersMin. 19/32"Plywood atMOP(psi)Optional)One or Ply CapMin.3/8-inchW-1 max. 24"spans attached more layers,anywith8dcommonorringcombination,loose SECUROCK Gypsum- See Note 2FiberRoofBoardshanknails,6"o.c. laid Fiber per 1 ft2 EasyBase (Optional) EasyStick Plus -52.5EasyBase TABLE 1B: WOOD DECKS—NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVERSYSTEMTYPEO: INSULATED, MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVERSystem No. Roof Deck Type Attach illMnlIlMln. 19/32"plywood at Y Cap MOP(perW_2 max.24"spans attached Any type, n Inch o.c. In the min.4-I with Bd common or ring thickness or Loose laid EasyLay See Note 2 Inch lap and 10-Inch o.c.Inshanknails,6"o.c. combination two,equally spaced, EasyBase EasyStick Plus 60.0staggeredcenterrows TABLE 1C-1: WOOD DECKS—NEW CONSTRUCTION or REROOF(Tear-Off)SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Type Fasteners Roo/Cover Min. 19/32" I AIIIIIIIIttach Ca MDP(perIIIIIIplywoodatmax.24" 12 ga.annular ring shank nails pspansattachedwithadcommaEasyLayandmin. 32 ga., 1-5/8" 7-Inch o.c.In the 4-Inch lap and 7- inch o.c.In three,equally spaced1517.5) ggered center.rows EasyBase EasyStick Plus -45.0 Min, 19/32"plywood at max.24' 12 ga.annular ring shank nailsW-4 spans attached with 8d Mg and min. 32 7-Inch o.c.In the 4-Inch lap and 7-ga., 1 inch o.c.In three,equally spaced,(Ref shank nails,6"o.c. diameter tin-caps. (Ref: FBC1517.5) staggered center rows EasyBase EasyStick Plus -60.0 Exterior Research and Design, LLC.d/b/a TrinitylERDCertificateofAuthonzatlon #9503Preparedby: Robert Nleminen, PE-59166 Evaluation Report Date of 1. 12.11 far 2/09/2- R1 of issuance: 12/09/2011 Appendix 1, Page 2 of 3 J' 1S APPENDDC 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE LI I ' Table Deck Application lA Wood Type DescriptionNew,Reroof(Tear-Off)or Recover C Mech.Attached Insulation, Bonded Roof Cover PageiBWoodNew, Retool(Tear-Off)or Recover 21C1Wood D Insulated, Mech.Attached Base Sheet, Bonded Roof CoverNeworReroof(Tear-Off) E Non-Insulated, Mech.Attached Base Sheet, Bonded Roof Cover 21C-2 Wood New, Reroof(Tear-0f or Recover 21DENon-Insulated, Mech.Attached Base Sheet, Bonded Roof CoverWoodNeworReroof(Tear-Off) F 3Non-Insulated, Bonded Roof Coverefoitowlnanotestpiabtoth®rvatem outlingi tion 3 Th 1. Roof decks shall be In accordance with FBC requirements to the satisfaction of the AFU. Wind load resistance of the roof deck shall be dpropercodifiedand/or FBC Approval documentation.ocumented through2. Unless otherwise noted, fasteners and stress plates for Insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: MP-3 Plates. Minimum 3A-Inch> Wood Deck: 0MG #12 or #14 HD with OMG 3 In. Galvalume Steel Plate or Tru-Fast DP or HD with 3 penetration or minimum 1-inch wood plank embedment nch plywood3. Unless otherwise noted, Insulation may be any one layer or combination of polylsocyanurate, polystyrene, wood fiberboard, perllte, DensDeck, DensDeck Prime,DensDeck DuraGuard, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and IsdocumentedasmeetingFBC1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.8, when Installed with the roof cover.4. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1designpressuredeterminedInaccordancewithFBCChapter16, and Zones 2 and 3 shall employ an attachment density designed by a qualified designprofessionaltoresisttheelevatedpressurecriteria. Commonly used me arelimitationssetforthinSection2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3enhanceS5117 and FM LPDS 1-29. Assemblies marked with an asterisk' carry the5. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressuredeterminedInaccordancewithFBCChapter16, and no rational analysis Is permitted.6. For mechanically attached components over existing decks, fasteners shall be tested In the existing deck for withdrawal resistance. A u ignprofessionalshallreviewthedataforcomparisontotheminimumrequirementsforthesystem. Testing and analysis shall be In accordance with TAS 105 orANSI/SPRI FX-1. qualified design 7. For existing substrates In a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibilityandperformancewiththeselectedadhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on Its own merit to thesatisfactionoftheAHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52,ANSI/SPRI IA-1 or TAS 124. bond 8. "MDP"= Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 fordeterminationofdesignwindloads. Exterior Research and Design,LLC. d/b/a TrinitylERDCertificateofAuthorization#9503 Evaluation ReportPreparedby: Robert NlemlnenPE-59166 739820.12.11 for -R1DateofIssuance: 12/09/2 09/2 011 Appendix 1,Page 1 of 3 I il'A) ( Zc‘ f - s ... TRINI ( ERD TABLE IA: WOOD DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVERSystemDeckBaseInsulationLayerNo. te Note 1) Top Insulation Layer 11111111.111111.0122121111TypeAttachTypeAttach Min.19/32-Inch Min.1.5-Inch MDP(psf) W 1 plywood or OSB at max. One or more EnergyGuard RA, Mln.OS-Inch Structodek High O Inch span 111011 EnergyGuard RH, GAF 2-Part Density Rberboard Roof GAF 2-Part BP-AA,$LAS AA BP-AA,585-AA,SBS-TA 5 S-TA orEnergyGuardRNInsulationAPP-TAorAPP-TAMtn.19/32-Inch Min.1.5-Inch Min.0.25-Inch Dens Deck,W-2. plywood or 058 at max. EnergyGuard RA Dens Prime or Optional)One or more224-Inch span EnergyGuard RH, GAF 2-Part Deck P G BP,585 AA,585Gypsum-Fiber TA or APP-TA BP-AA,SBS-AA,SBS-TA 58.5-AA,585-TA orEnergyGuardRNRoofBoardorAPP-TA APP-TA 52.5 Min.19/32-inch Min.1.5-Inch Min.0.25-Inch Dens Deck,W-3. plywood of O58 at max. EnergyGuard RA Dens Deck Prime or Weatherwatch XTEnergyGuardRH, GAF 2-Part Optional)585-TA,APP_24-Inch span SECUROCK Gypsum-Fiber GAF 2-Part Mat Surfaced LeakEnergyGuardRNRoofBoardBarrier TA SOS-TA,APP- TAIN TABLE 18-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAIf-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVERDeckSystemDe No. I Deckote InsulationTypeFastenersAttachMD?CONVExnonu Srsrts+s: Attach Ph Cap (per j MIH.1-inch A1In.0.5-InchMin.15/32- GAFGLAS W75 Base Sheet, 32 ga.,1- 8 inch o.c.at EnergyGuard PotyLso Strudodek HighinchTN-Ply#75 Base Sheet 5/8-Inch dia. min.4-inch laps Insulation, Density FiberboardW-d• plywood at GAFGLAS b80 Ultima Base tin caps with and 8-inch o.c.In EnergyGuard Ultra Roof Insulation or Optional) max.24 Sheet,GAFGLAS Stratavent 11 ga. w equally Polyiso Insulation or 8sp EnergyGuard Partite Hot 8P-AA,SBS Bp-AA, SBS-AA Inch span Nallable Venting Base annular ringsEnergyGuard RH halt Recover Board or Min. asphalt AA SBS AA, 585-TA, d5.0Sheet,Ruberold 20 Smooth shank nails staggered center Polylso or min.1.5- 0.75-Inch EnergyGuard 5 Ta APP-TA rows Inch EnergyGuard RA Perlite Roof Insulation I APP-TA or EnergyGuard RN homogeneous) Min.1-Inch MIn.15/32-GAFGLAS#75 Base Sheet, 32 ga,,1- 8-inch o.c.at EnergyGuard Polyiso Inch Trf Ply a75 Base Sheet, min.4-Inch laps Insulation, W-5. plywood at GAFGLAS#80 Ultima Base 5/8-inch and 8 inch o.c.in EnergyGuard Ultra Min.0.25-inch Dens Optional) Sheet,GAFGLAS Strataven[ 11 ga, two,equally Polylso Insulation or Deck Prime or Hot j BP-AA,SBS BP-AA max.24 SECUROCK Gypsum- AA,585-TA 585-AA, 5B5-TinchspanNallableVentingBaseannularring spared' EnergyGuard RH asphalt A -45.0Sheet,Ruberoid 20 Smooth shank nails staggered center Polylso or min.1.5. Fiber Roof Board APP-TA 585 TA, APP-TA rows Inch EnergyGuard RA APP-TA or EnergyGuard RNExteriorResearchandDesign,LLC.d/b/a Trinity(ERDCertificateofAuthorization#9503Evaluation Report OL506.11.040Ri8forFL56g0 18Preparedby: Robert Nleminen,PE-59166 FBC NON-HVHZ EVALUATION;GAF Modified Bitumen Roof Systems GAF:(800)766-3411 Revision 18:04/12/2017 Appendix 1,Page 5 of 85 TRN TY H ERD TABLE 1C-2: WOOD DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVERSYSTEMTYPEE: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVERSystem I No. Roof Deck Fasteners Roof Cover Attach Ply Cap MDP(psf)Min. 19/32"plywood at max.24'NI spans attached with Bd common 10-Inch o.c.In the min. 4-Inch lap and 10-Inchorringshanknails,6'o c See Note 2 o c.in two,equally spaced,staggeredgyred center EasyBase EasyStick Plus -60.0 TABLE 1D: WOOD DECKS-NEW CONSTRUCTION or REROOF(Tear-Off)SYSTEM TYPE F: BONDED ROOF COVERSystem No. Roof Deck Base Ply MDP(psf)2111 Min. 19/32"plywood at max.24"spans Capattachedwith8dclnrubAciknails, 6' Esyyc.c. Optional)Easy Base EasyStick Plus 75.0 psf Exterior Research and Design, LLC,d/b/a TrinitylERDCertificateofAuthorization Nie # 9503 Evaluation Report 739820.12.11 for 2/09/ R1Preparedby: Robert Nieminen, PE-59166 Date of Issuance: 12/09/2011 Appendix 1,Page 3 of 3