Loading...
1025 EAST COAST DR RES24-0032 A3a_ExtDoors_ThermaTru_FL20461_R9_II_(h) Inst 20461.1© 2016 R.W. Building Consultants Inc.INSWING/OUTSWING"NON-IMPACT"COMPOSITE EDGEOPAQUE FIBERGLASS SINGLE DOORTABLE OF CONTENTSSHEET # DESCRIPTION1Typical Elevations, Design Pressures & General Notes2 Door Panel Details3Elevations4Horizontal & Vertical Cross Sections (2X Buck)5Horizontal & Vertical Cross Sections (1X Buck)6Horizontal & Vertical Cross Sections (Direct to Masonry)7Vertical Cross Sections (Thresholds)8Buck & Frame Anchoring9Hardware Details10Components11Components & Bill of MaterialsX37.75" MAX O.A.FRAME WIDTH81.25" MAX. O.A. FRAME HEIGHT (OUTSWING) 82" MAX. O.A. FRAME HEIGHT (INSWING)Latch & DeadboltPOSITIVE+70.0-75.0POSITIVENEGATIVEDESIGN PRESSURE (PSF)OUTSWINGDESIGN PRESSURE (PSF)INSWINGLOCKHARDWARECONFIGURATIONX+67.0 -67.0NEGATIVESee Sheet 3 for Hardware SpecificationsX+80.0 -80.0 +80.0 -80.0Multipoint GENERAL NOTES1. This product has been evaluated and is in compliance with the 8th Edition (2023)Florida Building Code (FBC) structural requirements excluding the "High VelocityHurricane Zone" (HVHZ).2. Product anchors shall be as listed and spaced as shown on details. Anchorembedment to base material shall be beyond wall dressing or stucco.3. For 2x stud framing construction, anchoring of these units shall be the same asthat shown for 2x buck masonry construction.4. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect.5. Fiber-Classic & Smooth-Star Door panels require the use of "J" part numbers and must be stained or painted within six months of installation.This item has been digitally signed and sealed byL. F. Schmidt, P.E. on the date adjacent to the seal.Printed copies of this document are notconsidered signed and sealed and the signaturemust be verified on any electronic copies.THIS PRODUCT APPROVAL IS VALIDONLY FOR THE STATE OF FLORIDAZ:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc.12HORIZONTAL CROSS SECTION42VERTICAL CROSS SECTION40DOOR PANELBOOK5.5"XBOTTOM RAIL(COMP.)FIBERGLASS SKIN(0.073" THK.)3279.25" MAX. DOOR PANEL HEIGHT 36.0" MAX.DOORPANEL WIDTH1222HORIZONTAL CROSS SECTION32VERTICAL CROSS SECTION41DOOR PANELHybrid Door5.5"X3279.25" MAX. DOOR PANEL HEIGHT 2242DOOR PANELU1 Door5.5"X4279.06" MAX. DOOR PANEL HEIGHT 2235.813" MAX.DOORPANEL WIDTH35.813" MAX.DOORPANEL WIDTHFOAM CORE(POLYURETHANE -1.9 PCF MIN.)EXTERIOREXTERIORINTERIORINTERIOR0.82"1.71"0.89"INTERIOREXTERIOR1.71"1.875"0.406"1.198"0.406"1.198"HINGE STILE(ENGINEERED WOOD)COMPOSITECAPLOCK BLOCK(12.5" LONG WOOD)STILE(ENGINEERED WOOD)COMPOSITECAPINTERIOREXTERIOR1.71"HINGE STILE(ENGINEERED WOOD)1.875"LOCK BLOCK(12.5" LONG LVL)0.5"1.198"0.5"1.198"STILE(ENGINEERED WOOD)0.82"1.71"COMPOSITECAPCOMPOSITECAPTOP RAIL(COMPOSITE/ENGINEEREDWOOD)0.89" Z:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc.14271516343536242526173747XSEE HARDWARECHARTMODELMANUFACTURERHARDWARE TABLEKNOB: SIGNATURE SERIESKWIKSETDEADBOLT: SIGNATURE SERIES (980)KNOB: F51SCHLAGEDEADBOLT: B60 MULTIPOINT : MPDGART (3 pt. Manual Tongue) HOPPE(THERMA-TRU)466656Fiber-Classic/Smooth-Star Door Panel OptionsProducts approved include all embossed and recessed panel doors.Similar glazed panel configurations are allowed.Panels shown are for illustration and are representative only.Z:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc.1-1/4" MIN.EMB. (TYP.)LCEB10.15" C-SINK(TYP)24HORIZONTAL CROSS SECTIONShown w/ 2X BuckOutswing shown (Inswing similar)242329640LEXTERIORINTERIOR4142D2770.15" C-SINK(TYP)404142C11-1/4" MIN.EMB. (TYP.)D34HORIZONTAL CROSS SECTIONShown w/ 2X BuckOutswing shown (Inswing similar)ELLEB71EXTERIORINTERIOR42C14VERTICAL CROSS SECTIONShown w/ 2X BuckOutswing shown (Inswing similar)1-1/4" MIN. EMB. (TYP.)4140DEXTERIORINTERIORB1.15" MIN.EMB. (TYP.)Z:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc.G27740414235HORIZONTAL CROSS SECTIONShown w/ 1X sub-buck Outswing shown (Inswing similar)AEC11-1/4" MIN.EMB. (TYP.)J71EXTERIORINTERIOR42C15VERTICAL CROSS SECTIONShown w/ 1X sub-buckOutswing shown (Inswing similar)4140ECC25HORIZONTAL CROSS SECTIONShown w/ 1X sub-buckOutswing shown (Inswing similar)242329640EXTERIORINTERIOR4142GE1-1/4" MIN.EMB. (TYP.)JA1X Buck to be secured tomasonry by othersAEXTERIORINTERIOR1Z:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc.INTERIOREXTERIORINTERIOREXTERIOR16VERTICAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 4-9/16" jamb 46VERTICAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 6-9/16" jamb ECC1.5"MAX.E1.5"MAX.26HORIZONTAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 4-9/16" jamb1.25" MIN.2"INTERIOREXTERIOR1.5"MAX.CM1.5" MIN. 4"1.5" MAX.56HORIZONTAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 6-9/16" jambCEEM1-1/4" MIN.EMB. (TYP.)N1.5" MIN. 4.25"1.5" MAX.EMNC1-1/4" MIN.EMB. (TYP.)66HORIZONTAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 6-9/16" jamb1.25" MIN. 2.25"INTERIOREXTERIOR1.5" MAX.CME36HORIZONTAL CROSS SECTIONShown Direct to MasonryOutswing only w/ 4-9/16" jambDIRECT TO MASONRY MAX. DESIGN PRESSURE:w/ STANDARD STRIKE = ± 55 PSFw/ SECURITY STRIKE = ± 65 PSF4041424041424041424041421111111-1/4" MIN.EMB. (TYP.)1-1/4" MIN.EMB. (TYP.)Z:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc.177EEEXTERIORINTERIOR832EXTERIORINTERIOR37VERTICAL CROSS SECTIONOutswing Sill17VERTICAL CROSS SECTIONInswing SillEEXTERIORINTERIOR101547VERTICAL CROSS SECTIONPublic Access Sill163839424140424140424140SEE NOTE 1SEE NOTE 1EEXTERIORINTERIOR93327VERTICAL CROSS SECTIONInswing Sill424140SEE NOTE 1SEE NOTE 1183637434445464748Notes:1. Sill Item #'s 16, 32, 33, 36, 37, 38, 39, 43, 44, 45, 46, 47 & 48 are attached to jambs w/ (3) #8 X 2-1/2" pfh screws or (3) 2.5" staples at each end.2. Sill Item #'s 17 & 18 are attached to jambs w/ (2) #8 X 2-1/2" pfh screws at each end.3. Sill Item #15 is attached to jambs utilizing (2) #10 X 2" pph SMS screws at each end.Z:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc. 6" (TYP.)14" MAX. O.C. (TYP.)1X BUCK2X BUCKDIRECT TOMASONRY4" (TYP.)4" (TYP.)16" MAX.O.C. (TYP.) HEAD & JAMBS(TYP.)DLJM HEAD & JAMBS(TYP.)2X BUCK ANCHORINGFRAME ANCHORINGFRAMEMASONRY(TYP.)2X BUCKBUCK4" (TYP.)4" (TYP.)13" MAX. O.C. (TYP.) HEAD & JAMBS(TYP.)D2X BUCK ANCHORING80 PSF MAX60 PSF MAXJAMB TO HEAD DETAIL(TYP.)(3) #8 x 2-1/2"PFH WSNZ:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc.LATCH & DEADBOLT DETAILKwiksetDIRECT TOMASONRY1X BUCK2X BUCKHINGE DETAIL2X BUCK1X BUCKDIRECT TOMASONRY292423LGMLGM2X BUCK1X BUCKDIRECT TOMASONRYGM2528262728A28252228AGMDIRECT TOMASONRY1X BUCK2X BUCKLATCH & DEADBOLT DETAILSchlageLGM2X BUCK1X BUCKDIRECT TOMASONRYLATCH & DEADBOLT DETAILMultipoint LockTONGUE STRIKE DETAILMultipoint Lock27LGM2X BUCK1X BUCKDIRECT TOMASONRYLGM2X BUCK1X BUCKDIRECT TOMASONRY3130STRIKE JAMBLatch and DeadboltHINGE JAMB11.25" FROM TOP OF JAMB 29.25" (TYP.) BOOK DOOR SEE HINGEDETAIL (TYP.)30.31"SEE TONGUESTRIKE DETAIL(TYP.)SEE LATCH& DEADBOLTDETAILSTRIKE JAMBMultipoint Lock29.75" (TYP.) U1/HYBRID DOOR 11.125" FROM TOP OF JAMB 25.37" 5.5"44.88" (± 1.5")SEE LATCH& DEADBOLTDETAILLATCH & DEADBOLT STRIKE DETAILS(Standard Deadbolt Strike Plate)MULTIPOINT LOCK STRIKE DETAILS45.25" (± 1.5")28BDEADBOLT STRIKE DETAILS(Security Deadbolt Strike Plate)MDIRECT TOMASONRYSUB STRIKEPLATEZ:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc. 1.55"7.5"4.56"1.55"33INSWING THRESHOLDInswing Basic Fixed Sill5.75"1.55"36INSWING THRESHOLDInswing Basic Fixed 5-3/4" Sill37INSWING THRESHOLDInswing Basic Fixed 7-1/2" Sill4.56"1.5"43INSWING THRESHOLDInswing Composite Adjustable SillBook, Hybrid5.83"1.5"7.63"1.5"4.56"1.3"46INSWING THRESHOLDInswing Composite Adjustable SillU15.83"1.3"7.63"1.3"47INSWING THRESHOLDInswing Composite Adjustable SillU148INSWING THRESHOLDInswing Composite Adjustable SillU144INSWING THRESHOLDInswing Composite Adjustable SillBook, Hybrid45INSWING THRESHOLDInswing Composite Adjustable SillBook, Hybrid38INSWING THRESHOLDInswing Composite Adjustable Sill4.56"1.5"39INSWING THRESHOLDInswing Composite Adjustable Sill32INSWING THRESHOLDInswing Composite Adjustable 7-3/4" Sill16OUTSWING THRESHOLDComposite / Aluminum Sill5.75"1.01"18OUTSWING THRESHOLDComposite / Aluminum Sill(Thermal Break)5.63"1.13"7.81"1.13"17OUTSWING THRESHOLDComposite / Aluminum Sill15PUBLIC ACCESS THRESHOLD6.0"0.5" 0.082"4.56"1" 1.5"5.83"Z:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg © 2016 R.W. Building Consultants Inc.BILL OF MATERIALSITEM #DESCRIPTIONMATERIALA1X BUCK (SG >= 0.42)WOODB2X BUCK (SG >= 0.42)WOODC1/4" MAX. SHIM SPACE-D1/4" X 2-3/4" PFH DeWALT OR ITW CONCRETE SCREWSTEELEMASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI301 OR HOLLOW BLOCK CONFORMING TO ASTM C90CONCRETEG3/16" X 3-1/4" ITW CONCRETE SCREWSTEELJ1/4" X 3-3/4" PFH DeWALT OR ITW CONCRETE SCREWSTEELL#10 X 2-1/2" PFH WOOD SCREW (1.15" MIN. EMBEDMENT)STEELM3/16" X 2-1/4" ITW CONCRETE SCREWSTEELN3/16" X 2-3/4" ITW CONCRETE SCREWSTEEL1JAMB (FINGER JOINT PINE )WOOD6WEATHERSTRIP (MEDIUM REACH)FOAM7WEATHERSTRIP (LONG REACH)FOAM8SWEEPVINYL9SWEEP (USE w/ INSWING BASIC FIXED SILLVINYL10SWEEP (USE w/ PUBLIC ACCESS THRESHOLD)VINYL15PUBLIC ACCESS THRESHOLDALUM16OUTSWING THRESHOLDALUM/COMP17OUTSWING THRESHOLDALUM/COMP18OUTSWING THRESHOLDALUM/COMP22#8 x 3/4" PFH WOOD SCREWSTEEL23#10 x 3/4" PFH WOOD SCREWSTEEL24#10 x 1" PFH WOOD SCREWSTEEL25#8 x 2-1/2" PFH WOOD SCREWSTEELBILL OF MATERIALSITEM #DESCRIPTIONMATERIAL26#8 x 5/8" PFH WOOD SCREWSTEEL27LATCH STRIKE PLATESTEEL28DEADBOLT STRIKE PLATE (STANDARD)STEEL28ADEADBOLT SUB STRIKE PLATESTEEL28BDEADBOLT STRIKE PLATE (SECURITY)STEEL294" X 4" HINGESTEEL30LATCH & DEADBOLT STRIKE PLATE (TONGUE SYSTEM)ALUM/COMP31MULTIPOINT STRIKE PLATE (TONGUE SYSTEM)ALUM/COMP32INSWING THRESHOLDALUM/COMP33INSWING THRESHOLDALUM/COMP36INSWING THRESHOLDALUM/COMP37INSWING THRESHOLDALUM/COMP38INSWING THRESHOLDALUM/COMP39INSWING THRESHOLDALUM/COMP40DOOR PANEL (BOOK)-41DOOR PANEL (HYBRID)-42DOOR PANEL (U1)-CONCRETE ANCHOR NOTES:Concrete anchor locations at the corners may be adjusted to maintain the min.edge distance to mortar joints.Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted tomaintain the min. edge distance to mortar joints, additional concrete anchorsmay be required to ensure the "MAX. ON CENTER" dimension are not exceeded.Concrete anchor table:2.1.1/4"MIN.EMBEDMENTANCHORSIZEMIN. CLEARANCETO ADJACENTANCHORMIN. CLEARANCETO MASONRYEDGEITWTAPCON1-1/4"2"4"ANCHORTYPE®3.1/4"DeWALT ULTRACON+1"4"®1-1/4"3/16"ITWTAPCON1-1/4"®AS SHOWN1-1/2"WOOD SCREW INSTALLATION NOTES:Maintain a minimum 5/8" edge distance, 1" end distance, & 1" o.c. spacing ofwood screws to prevent the splitting of wood.1.43INSWING THRESHOLDALUM/COMP44INSWING THRESHOLDALUM/COMP45INSWING THRESHOLDALUM/COMP46INSWING THRESHOLDALUM/COMP47INSWING THRESHOLDALUM/COMP48INSWING THRESHOLDALUM/COMP1WOOD JAMB4.56"0.75" 1.25"2.36"0.45"1.79"8SWEEP2.06"0.68"10SWEEP1.92"0.91"9SWEEPZ:\2023 FBC Drawings\Therma-Tru\ThermaTru FL 20461\FL-20461.1-5.dwg