1025 EAST COAST DR RES24-0032 B1_Windows_FL31123_R2_II_RWD0001_Rev0_8500SH_ssRJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueRENAISSANCE WINDOWS AND DOORS
SERIES 9IN</ SIN*/E +8N* WINDOW
INS7A//A7ION ANC+ORA*E DE7AI/S
N.T.S.GENERAL NOTES, INSTALLATION NOTES & TABLE OF CONTENTS1GENERAL NOTES:
1.THIS PRODUCT HAS BEEN TESTED, EVALUATED AND DESIGNED TO THE CURRENT EDITION OF THE FLORIDA BUILDING CODE. TESTING WAS
CONDUCTED IN ACCORDANCE WITH AAMA/NWWDA 101/I.S.2-97.
2.THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED TEST REPORT NO.02-48976.01 AND 02-48976.02 AND
ASSOCIATED LABORATORY DRAWINGS BY ARCHITECTURAL TESTING, INC.
3.THIS PRODUCT EVALUATION DOCUMENT IS NOT FOR USE IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ).
4.ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE / MASONRY AND 2X FRAMING FRAMING SUBSTRATES AS A MAIN WIND FORCE
RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE
RESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING AS THE DESIGN PROFESSIONAL OF
RECORD FOR THE PROJECT OF INSTALLATION.
5.1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK
DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING AS
THE DESIGN PROFESSIONAL OF RECORD FOR THE PROJECT OF INSTALLATION.
6.WHEN INSTALLED IN LOCATIONS WHERE WINDBORNE DEBRIS PROTECTION REQUIREMENTS EXIST,THIS PRODUCT REQUIRES OPENING
PROTECTION IN ACCORDANCE WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE USING AN APPROVED IMPACT PROTECTION
DEVICE.
7.SITE CONDITIONS NOT COVERED IN THIS PRODUCT EVALUATION DOCUMENT ARE SUBJECT TO ADDITIONAL ENGINEERING ANALYSIS BY A
LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
8.WINDOW FRAME MATERIAL: VINYL (PVC).
9.GLASS MEETS THE REQUIREMENTS OF ASTM E1300-09a.
10.DESIGNATIONS "X" STANDS FOR OPERABLE LITE/SASH AND "O" STANDS FOR FIXED LITE.
11.THESE DRAWINGS CERTIFY THE WINDOW INSTALLATION ONLY. WATER PROOFING OF THE INSTALLED WINDOW IS NOT PART OF THIS
INSTALLATION CERTIFICATION. THAT RESPONSIBILITY SHALL BE THAT OF THE MANUFACTURER AND/OR THE INSTALLER.
INSTALLATION NOTES:
1.PRODUCT ANCHORS SHALL BE AS DESIGNATED AND LOCATED AS SHOWN IN
THIS PRODUCT EVALUATION DOCUMENT. ANCHOR EMBEDMENT AND EDGE
DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO,
FOAM, BRICK VENEER AND SIDING.
2.SEE INSTALLATION ANCHOR SCHEDULE ON SHEET 2 FOR TYPE AND GRADE OF
ANCHOR, AND/OR MANUFACTURER'S ANCHOR SPECIFICATIONS, INCLUDING
MINIMUM NOMINAL SIZE, MINIMUM EMBEDMENT INTO SUBSTRATE AND MINIMUM
EDGE DISTANCES.
2.1.EDGE DISTANCES SHALL BE MEASURED FROM CENTERLINE OF ANCHOR TO
EDGE OF STRUCTURAL SUBSTRATE EITHER TO THE INTERIOR OR EXTERIOR
OF THE FENESTRATION PRODUCT.
2.2.MINIMUM EMBEDMENT SHALL BE BASED ON PENETRATION INTO MAIN WIND
FORCE RESISTING SYSTEM SUBSTRATE.
3.SEE SHEETS 5 THROUGH 10 FOR SPECIFIC ANCHOR INSTALLATION DETAILS.
4.ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION
SHOWN.
5.ANCHOR QUANTITIES AND SPACING / EMBEDMENT AND EDGE DISTANCE
5.1.THE NUMBER OF INSTALLATION ANCHORS IS BASED ON THE MAXIMUM END
DISTANCE (ED) AND THE MAXIMUM ON CENTER (O.C.) SPACING PLACEMENT
OF ANCHORS IN ACCORDANCE WITH ELEVATIONS ON SHEETS 3 AND 4.
5.2.END DISTANCES AND O.C. SPACINGS LESS THAN THAT SHOWN IN THE
ELEVATIONS ON SHEETS 3 AND 4 ARE ACCEPTABLE.
5.3.FOR WINDOW SIZES SMALLER THAN THOSE SHOWN, ANCHOR QUANTITIES
CAN BE REDUCED WHILE MAINTAINING EDGE DISTANCE AND O.C. SPACING
REQUIREMENTS.
5.4.ANCHOR QUANTITIES AND SPACINGS SHOWN ARE BASED ON THE LOWER OF
ANCHOR SPACING USED IN TESTING OR REQUIRED BY LOADING AT DESIGN
PRESSURE.
5.5.SEE EMBEDMENT AND EDGE DISTANCE DESCRIPTION ON SHEET 2.
6.MAXIMUM ALLOWABLE SHIM THICKNESS IS 1/4 INCH. SHIM WHERE SPACE OF
1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF WOOD
COMPOSITE, HIGH DENSITY PLASTIC OR SIMILAR LOAD BEARING MATERIAL.
7.FOR CONCRETE BLOCK APPLICATIONS DO NOT INSTALL INSTALLATION
ANCHORS INTO MORTAR JOINTS.
8.INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE
USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH
SPECIFIED IN THE INSTALLATION ANCHOR SCHEDULE ON SHEET 2.
TABLE OF CONTENTS
SHEET SHEET DESCRIPTION
1 GENERAL NOTES, INSTALLATION NOTES, TABLE OF CONTENTS
2 ANCHOR SCHEDULE - EMBEDMENT AND EDGE DISTANCE
3 48" x 84" WINDOW ELEVATION/COMBINED ANCHORING LAYOUT
4 44" x 84" WINDOW ELEVATION/FIN FRAME ANCHORING LAYOUT
5 44" x 84" WINDOW ELEVATION/THRU-FRAME ANCHORING LAYOUT
6 VERTICAL CROSS SECTION - NAILING FIN INSTALLATION
7 HORIZONTAL CROSS SECTION - NAILING FIN INSTALLATION
8 VERTICAL CROSS SECTION - THRU FRAME INSTALLATION
9 HORIZONTAL CROSS SECTION - THRU FRAME INSTALLATION
10 VERTICAL CROSS SECTION - SNAP-ON FLANGE THRU FRAME INSTALLATION
11 HORIZONTAL CROSS SECTION - SNAP-ON FLANGE THRU FRAME INSTALLATION
12 GLAZING DETAIL AND GLAZING NOTES
13 BILL OF MATERIALS
PERFORMANCE RATING
MAXIMUM WINDOW SIZE GLAZING DETAIL
(SEE SHEET 12)DESIGN PRESSURE (PSF)IMPACT RATING
NOMINAL 48" x 84"B (FIXED LITE)
C (SASH LITE)+/- 25
NONE
SEE NOTE 6
NOMINAL 44" x 84"A (FIXED LITE)
C (SASH LITE)+/- 40
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueEMBEDMENT AND EDGE DISTANCE
NAILING FIN FRAME INSTALLATION
EMBEDMENT AND EDGE DISTANCE
THROUGH-FRAME INSTALLATION
EMBEDMENT AND EDGE DISTANCE
SNAP-ON FLANGE THROUGH-FRAME INSTALLATION N.T.S.ANCHOR SCHEDULE - EMBEDMENT & EDGE DISTANCE1
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueSERIES 8500 VINYL SINGLE HUNG WINDOW - 25 PSF DESIGN PRESSURE
EXTERIOR VIEW - SPLIT LITE WINDOW (48" X 84" NOMINAL SIZE SHOWN) - GLAZING DETAIL B & C
FIN FRAME ANCHOR INSTALLATION SHOWN - THRU-FRAME ANCHOR INSTALLATION SAME
X
O
B
7
C
7
C
9
C
11
B
9
B
11
A
6
A
8
A
10
N.T.S.48" x 84" WINDOW ELEVATION/ COMBINED ANCHORING LAYOUT3
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueSERIES 8500 VINYL SINGLE HUNG WINDOW - 40 PSF DESIGN PRESSURE
EXTERIOR VIEW - SPLIT LITE WINDOW (44" X 84" NOMINAL SIZE SHOWN) - GLAZING DETAIL A & C
FIN FRAME ANCHOR INSTALLATION
B
7
C
X
O
A
6
7 N.T.S.44" x 84" WINDOW ELEVATION/FIN FRAME ANCHORING LAYOUT4
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueSERIES 8500 VINYL SINGLE HUNG WINDOW - 40 PSF DESIGN PRESSURE
EXTERIOR VIEW - SPLIT LITE WINDOW (44" X 84" NOMINAL SIZE SHOWN) - GLAZING DETAIL A & C
THRU-FRAME ANCHOR INSTALLATION
B
9
C
X
O
A
8
9
C
11
B
11
A
10
N.T.S.44" x 84" WINDOW ELEVATION/THRU-FRAME ANCHORING LAYOUT5
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueVERTICAL CROSS SECTION
NAILING FIN FRAME INSTALLATION6
A
EXTERIOR INTERIOR N.T.S.VERTICAL CROSS SECTION - NAILING FIN INSTALLATION6
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueFIXED LITE HORIZOINTAL
CROSS SECTION
NAILING FIN FRAME INSTALLATION
7
B
SASH LITE HORIZONTAL
CROSS SECTION
NAILING FIN FRAME INSTALLATION
7
C
EXTERIOR
EXTERIOR
INTERIOR
INTERIOR N.T.S.HORIZONTAL CROSS SECTION - NAILING FIN INSTALLATION7
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueVERTICAL CROSS SECTION
THROUGH-FRAME INSTALLATION8
A
EXTERIOR INTERIOR N.T.S.VERTICAL CROSS SECTION - THRU FRAME INSTALLATION8
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueFIXED LITE HORIZOINTAL
CROSS SECTION
THROUGH-FRAME INSTALLATION
9
B
SASH LITE HORIZONTAL
CROSS SECTION
THROUGH-FRAME INSTALLATION
9
C
EXTERIOR
EXTERIOR
INTERIOR
INTERIOR N.T.S.HORIZONTAL CROSS SECTION - THRU FRAME INSTALLATION9
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueVERTICAL CROSS SECTION
SNAP-ON FLANGE
THROUGH-FRAME INSTALLATION10
A
EXTERIOR INTERIOR N.T.S.VERT. CROSS SECTION - SNAP-ON FLANGE THRU FRAME INST.10
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueFIXED LITE HORIZOINTAL
CROSS SECTION
SNAP-ON FLANGE
THROUGH-FRAME INSTALLATION
11
B
SASH LITE HORIZONTAL
CROSS SECTION
SNAP-ON FLANGE
THROUGH-FRAME INSTALLATION
11
C
EXTERIOR
EXTERIOR
INTERIOR
INTERIOR N.T.S.HORIZ. CROSS SECTION - SNAP-ON FLANGE THRU FRAME INST.11
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueGLAZING DETAIL A
APPLICABLE AT FIXED LITE FOR DESIGN PRESSURE
GREATER THAN 25 PSF
GLAZING DETAIL B
NOTES:
1.A MINIMUM OF TWO (2) NEOPRENE SETTING BLOCKS WITH 70 TO 90 SHORE A DUROMETER
HARDNESS ARE REQUIRED AT BOTTOM (SILL) OF GLAZING LITES MORE THAN 3 FEET IN
WIDTH.
2.AS-TESTED IGU SYSTEM SHOWN. OTHER SUBSTITUTES ARE ALLOW WHILE MAINTAINING
INDIVIDUAL LITE THICKNESS AND TEMPER.
GLAZING DETAIL C N.T.S.GLAZING DETAILS AND NOTES12
RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.
Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueN.T.S.BILL OR MATERIALS13