Loading...
1025 EAST COAST DR RES24-0032 B1a_Windows_RWD-SINGLE-HUNG-INSTALLATIONRJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueRENAISSANCE WINDOWS AND DOORS SERIES  9IN</ SIN*/E +8N* WINDOW INS7A//A7ION ANC+ORA*E DE7AI/S N.T.S.GENERAL NOTES, INSTALLATION NOTES & TABLE OF CONTENTS1GENERAL NOTES: 1. THIS PRODUCT HAS BEEN TESTED, EVALUATED AND DESIGNED TO THE CURRENT EDITION OF THE FLORIDA BUILDING CODE. TESTING WASCONDUCTED IN ACCORDANCE WITH AAMA/NWWDA 101/I.S.2-97. 2. THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED TEST REPORT NO.02-48976.01 AND 02-48976.02 ANDASSOCIATED LABORATORY DRAWINGS BY ARCHITECTURAL TESTING, INC. 3. THIS PRODUCT EVALUATION DOCUMENT IS NOT FOR USE IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 4. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE / MASONRY AND 2X FRAMING FRAMING SUBSTRATES AS A MAIN WIND FORCERESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THERESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING AS THE DESIGN PROFESSIONAL OF RECORD FOR THE PROJECT OF INSTALLATION. 5.1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING ASTHE DESIGN PROFESSIONAL OF RECORD FOR THE PROJECT OF INSTALLATION. 6. WHEN INSTALLED IN LOCATIONS WHERE WINDBORNE DEBRIS PROTECTION REQUIREMENTS EXIST,THIS PRODUCT REQUIRES OPENINGPROTECTION IN ACCORDANCE WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE USING AN APPROVED IMPACT PROTECTION DEVICE. 7. SITE CONDITIONS NOT COVERED IN THIS PRODUCT EVALUATION DOCUMENT ARE SUBJECT TO ADDITIONAL ENGINEERING ANALYSIS BY A LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 8. WINDOW FRAME MATERIAL: VINYL (PVC). 9. GLASS MEETS THE REQUIREMENTS OF ASTM E1300-09a. 10. DESIGNATIONS "X" STANDS FOR OPERABLE LITE/SASH AND "O" STANDS FOR FIXED LITE. 11. THESE DRAWINGS CERTIFY THE WINDOW INSTALLATION ONLY. WATER PROOFING OF THE INSTALLED WINDOW IS NOT PART OF THIS INSTALLATION CERTIFICATION. THAT RESPONSIBILITY SHALL BE THAT OF THE MANUFACTURER AND/OR THE INSTALLER. INSTALLATION NOTES: 1. PRODUCT ANCHORS SHALL BE AS DESIGNATED AND LOCATED AS SHOWN INTHIS PRODUCT EVALUATION DOCUMENT. ANCHOR EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO,FOAM, BRICK VENEER AND SIDING. 2. SEE INSTALLATION ANCHOR SCHEDULE ON SHEET 2 FOR TYPE AND GRADE OFANCHOR, AND/OR MANUFACTURER'S ANCHOR SPECIFICATIONS, INCLUDINGMINIMUM NOMINAL SIZE, MINIMUM EMBEDMENT INTO SUBSTRATE AND MINIMUM EDGE DISTANCES.2.1. EDGE DISTANCES SHALL BE MEASURED FROM CENTERLINE OF ANCHOR TOEDGE OF STRUCTURAL SUBSTRATE EITHER TO THE INTERIOR OR EXTERIOR OF THE FENESTRATION PRODUCT. 2.2. MINIMUM EMBEDMENT SHALL BE BASED ON PENETRATION INTO MAIN WINDFORCE RESISTING SYSTEM SUBSTRATE. 3. SEE SHEETS 5 THROUGH 10 FOR SPECIFIC ANCHOR INSTALLATION DETAILS. 4.ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATIONSHOWN. 5.ANCHOR QUANTITIES AND SPACING / EMBEDMENT AND EDGE DISTANCE5.1.THE NUMBER OF INSTALLATION ANCHORS IS BASED ON THE MAXIMUM ENDDISTANCE (ED) AND THE MAXIMUM ON CENTER (O.C.) SPACING PLACEMENT OF ANCHORS IN ACCORDANCE WITH ELEVATIONS ON SHEETS 3 AND 4.5.2.END DISTANCES AND O.C. SPACINGS LESS THAN THAT SHOWN IN THEELEVATIONS ON SHEETS 3 AND 4 ARE ACCEPTABLE.5.3.FOR WINDOW SIZES SMALLER THAN THOSE SHOWN, ANCHOR QUANTITIES CAN BE REDUCED WHILE MAINTAINING EDGE DISTANCE AND O.C. SPACINGREQUIREMENTS.5.4.ANCHOR QUANTITIES AND SPACINGS SHOWN ARE BASED ON THE LOWER OF ANCHOR SPACING USED IN TESTING OR REQUIRED BY LOADING AT DESIGNPRESSURE.5.5.SEE EMBEDMENT AND EDGE DISTANCE DESCRIPTION ON SHEET 2. 6. MAXIMUM ALLOWABLE SHIM THICKNESS IS 1/4 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF WOOD COMPOSITE, HIGH DENSITY PLASTIC OR SIMILAR LOAD BEARING MATERIAL. 7. FOR CONCRETE BLOCK APPLICATIONS DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. 8. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BEUSED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED IN THE INSTALLATION ANCHOR SCHEDULE ON SHEET 2. TABLE OF CONTENTS SHEET SHEET DESCRIPTION 1 GENERAL NOTES, INSTALLATION NOTES, TABLE OF CONTENTS 2 ANCHOR SCHEDULE - EMBEDMENT AND EDGE DISTANCE 3 48" x 84" WINDOW ELEVATION/COMBINED ANCHORING LAYOUT 4 44" x 84" WINDOW ELEVATION/FIN FRAME ANCHORING LAYOUT 5 44" x 84" WINDOW ELEVATION/THRU-FRAME ANCHORING LAYOUT 6 VERTICAL CROSS SECTION - NAILING FIN INSTALLATION 7 HORIZONTAL CROSS SECTION - NAILING FIN INSTALLATION 8 VERTICAL CROSS SECTION - THRU FRAME INSTALLATION 9 HORIZONTAL CROSS SECTION - THRU FRAME INSTALLATION 10 VERTICAL CROSS SECTION - SNAP-ON FLANGE THRU FRAME INSTALLATION 11 HORIZONTAL CROSS SECTION - SNAP-ON FLANGE THRU FRAME INSTALLATION 12 GLAZING DETAIL AND GLAZING NOTES 13 BILL OF MATERIALS PERFORMANCE RATING MAXIMUM WINDOW SIZE GLAZING DETAIL(SEE SHEET 12)DESIGN PRESSURE (PSF)IMPACT RATING NOMINAL 48" x 84"B (FIXED LITE) C (SASH LITE)+/- 25 NONE SEE NOTE 6NOMINAL 44" x 84"A (FIXED LITE) C (SASH LITE)+/- 40 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueEMBEDMENT AND EDGE DISTANCE NAILING FIN FRAME INSTALLATION EMBEDMENT AND EDGE DISTANCE THROUGH-FRAME INSTALLATION EMBEDMENT AND EDGE DISTANCE SNAP-ON FLANGE THROUGH-FRAME INSTALLATION N.T.S.ANCHOR SCHEDULE - EMBEDMENT & EDGE DISTANCE1 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueSERIES 8500 VINYL SINGLE HUNG WINDOW - 25 PSF DESIGN PRESSURE EXTERIOR VIEW - SPLIT LITE WINDOW (48" X 84" NOMINAL SIZE SHOWN) - GLAZING DETAIL B & C FIN FRAME ANCHOR INSTALLATION SHOWN - THRU-FRAME ANCHOR INSTALLATION SAME X O B7 C7 C9 C11 B9 B11 A6 A8 A10 N.T.S.48" x 84" WINDOW ELEVATION/ COMBINED ANCHORING LAYOUT3 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueSERIES 8500 VINYL SINGLE HUNG WINDOW - 40 PSF DESIGN PRESSURE EXTERIOR VIEW - SPLIT LITE WINDOW (44" X 84" NOMINAL SIZE SHOWN) - GLAZING DETAIL A & C FIN FRAME ANCHOR INSTALLATION B7 C X O A6 7 N.T.S.44" x 84" WINDOW ELEVATION/FIN FRAME ANCHORING LAYOUT4 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueSERIES 8500 VINYL SINGLE HUNG WINDOW - 40 PSF DESIGN PRESSURE EXTERIOR VIEW - SPLIT LITE WINDOW (44" X 84" NOMINAL SIZE SHOWN) - GLAZING DETAIL A & C THRU-FRAME ANCHOR INSTALLATION B9 C X O A8 9 C11 B11 A10 N.T.S.44" x 84" WINDOW ELEVATION/THRU-FRAME ANCHORING LAYOUT5 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueVERTICAL CROSS SECTION NAILING FIN FRAME INSTALLATION6 A EXTERIOR INTERIOR N.T.S.VERTICAL CROSS SECTION - NAILING FIN INSTALLATION6 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueFIXED LITE HORIZOINTAL CROSS SECTION NAILING FIN FRAME INSTALLATION 7 B SASH LITE HORIZONTAL CROSS SECTION NAILING FIN FRAME INSTALLATION 7 C EXTERIOR EXTERIOR INTERIOR INTERIOR N.T.S.HORIZONTAL CROSS SECTION - NAILING FIN INSTALLATION7 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueVERTICAL CROSS SECTION THROUGH-FRAME INSTALLATION8 A EXTERIOR INTERIOR N.T.S.VERTICAL CROSS SECTION - THRU FRAME INSTALLATION8 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueFIXED LITE HORIZOINTAL CROSS SECTION THROUGH-FRAME INSTALLATION 9 B SASH LITE HORIZONTAL CROSS SECTION THROUGH-FRAME INSTALLATION 9 C EXTERIOR EXTERIOR INTERIOR INTERIOR N.T.S.HORIZONTAL CROSS SECTION - THRU FRAME INSTALLATION9 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueVERTICAL CROSS SECTION SNAP-ON FLANGE THROUGH-FRAME INSTALLATION10 A EXTERIOR INTERIOR N.T.S.VERT. CROSS SECTION - SNAP-ON FLANGE THRU FRAME INST.10 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueFIXED LITE HORIZOINTAL CROSS SECTION SNAP-ON FLANGE THROUGH-FRAME INSTALLATION 11 B SASH LITE HORIZONTAL CROSS SECTION SNAP-ON FLANGE THROUGH-FRAME INSTALLATION 11 C EXTERIOR EXTERIOR INTERIOR INTERIOR N.T.S.HORIZ. CROSS SECTION - SNAP-ON FLANGE THRU FRAME INST.11 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueGLAZING DETAIL A APPLICABLE AT FIXED LITE FOR DESIGN PRESSURE GREATER THAN 25 PSF GLAZING DETAIL B NOTES: 1. A MINIMUM OF TWO (2) NEOPRENE SETTING BLOCKS WITH 70 TO 90 SHORE A DUROMETER HARDNESS ARE REQUIRED AT BOTTOM (SILL) OF GLAZING LITES MORE THAN 3 FEET IN WIDTH. 2. AS-TESTED IGU SYSTEM SHOWN. OTHER SUBSTITUTES ARE ALLOW WHILE MAINTAINING INDIVIDUAL LITE THICKNESS AND TEMPER. GLAZING DETAIL C N.T.S.GLAZING DETAILS AND NOTES12 RJA13OFRWD0001SERIES 8500 VINYL SINGLE HUNG WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E.Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREV DESCRIPTIONDATEBY12/5/19RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218PROJECT # 419-0901First IssueN.T.S.BILL OR MATERIALS13