Loading...
1025 EAST COAST DR RES24-0032 B5_Windows_FL31115_R2_II_RWD0002_Rev0_8500F_ssRJA8OF12/5/19RWD0002SERIES 8500 VINYL FIXED WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218Robert J. Amoruso, P.E. Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBYPROJECT # 419-0901First IssueRENAISSANCE WINDOWS AND DOORS SERIES  9IN</ )I;ED WINDOW INS7A//A7ION ANC+ORA*E DE7AI/S N.T.S.GENERAL NOTES, INSTALLATION NOTES & TABLE OF CONTENTS1GENERAL NOTES: 1.THIS PRODUCT HAS BEEN TESTED, EVALUATED AND DESIGNED TO THE CURRENT EDITION OF THE FLORIDA BUILDING CODE. TESTING WAS CONDUCTED IN ACCORDANCE WITH AAMA/NWWDA 101/I.S.2-97 AND AAMA/WDMA/CSA 101/I.S.2/A440-05. 2.THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED TEST REPORT NO.77856.01-801-44 AND 02-46046.01 AND ASSOCIATED LABORATORY DRAWINGS BY ARCHITECTURAL TESTING, INC. 3.THIS PRODUCT EVALUATION DOCUMENT IS NOT FOR USE IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 4.ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE / MASONRY AND 2X FRAMING FRAMING SUBSTRATES AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING AS THE DESIGN PROFESSIONAL OF RECORD FOR THE PROJECT OF INSTALLATION. 5.1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING AS THE DESIGN PROFESSIONAL OF RECORD FOR THE PROJECT OF INSTALLATION. 6.WHEN INSTALLED IN LOCATIONS WHERE WINDBORNE DEBRIS PROTECTION REQUIREMENTS EXIST,THIS PRODUCT REQUIRES OPENING PROTECTION IN ACCORDANCE WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE USING AN APPROVED IMPACT PROTECTION DEVICE. 7.SITE CONDITIONS NOT COVERED IN THIS PRODUCT EVALUATION DOCUMENT ARE SUBJECT TO ADDITIONAL ENGINEERING ANALYSIS BY A LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 8.WINDOW FRAME MATERIAL: VINYL (PVC). 9.GLASS MEETS THE REQUIREMENTS OF ASTM E1300-09a. 10.DESIGNATION "O" STANDS FOR FIXED LITE. 11.THESE DRAWINGS CERTIFY THE WINDOW INSTALLATION ONLY. WATER PROOFING OF THE INSTALLED WINDOW IS NOT PART OF THIS INSTALLATION CERTIFICATION. THAT RESPONSIBILITY SHALL BE THAT OF THE MANUFACTURER AND/OR THE INSTALLER. INSTALLATION NOTES: 1.PRODUCT ANCHORS SHALL BE AS DESIGNATED AND LOCATED AS SHOWN IN THIS PRODUCT EVALUATION DOCUMENT. ANCHOR EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER AND SIDING. 2.SEE INSTALLATION ANCHOR SCHEDULE ON SHEET 2 FOR TYPE AND GRADE OF ANCHOR, AND/OR MANUFACTURER'S ANCHOR SPECIFICATIONS, INCLUDING MINIMUM NOMINAL SIZE, MINIMUM EMBEDMENT INTO SUBSTRATE AND MINIMUM EDGE DISTANCES. 2.1.EDGE DISTANCES SHALL BE MEASURED FROM CENTERLINE OF ANCHOR TO EDGE OF STRUCTURAL SUBSTRATE EITHER TO THE INTERIOR OR EXTERIOR OF THE FENESTRATION PRODUCT. 2.2.MINIMUM EMBEDMENT SHALL BE BASED ON PENETRATION INTO MAIN WIND FORCE RESISTING SYSTEM SUBSTRATE. 3.SEE SHEETS 5 THROUGH 7 FOR SPECIFIC ANCHOR INSTALLATION DETAILS. 4.ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 5.ANCHOR QUANTITIES AND SPACING / EMBEDMENT AND EDGE DISTANCE 5.1.THE NUMBER OF INSTALLATION ANCHORS IS BASED ON THE MAXIMUM END DISTANCE (ED) AND THE MAXIMUM ON CENTER (O.C.) SPACING PLACEMENT OF ANCHORS IN ACCORDANCE WITH ELEVATIONS ON SHEETS 3 AND 4. 5.2.END DISTANCES AND O.C. SPACINGS LESS THAN THAT SHOWN IN THE ELEVATIONS ON SHEETS 3 AND 4 ARE ACCEPTABLE. 5.3.FOR WINDOW SIZES SMALLER THAN THOSE SHOWN, ANCHOR QUANTITIES CAN BE REDUCED WHILE MAINTAINING EDGE DISTANCE AND O.C. SPACING REQUIREMENTS. 5.4.ANCHOR QUANTITIES AND SPACINGS SHOWN ARE BASED ON THE LOWER OF ANCHOR SPACING USED IN TESTING OR REQUIRED BY LOADING AT DESIGN PRESSURE. 5.5.SEE EMBEDMENT AND EDGE DISTANCE DESCRIPTION ON SHEET 2. 6.MAXIMUM ALLOWABLE SHIM THICKNESS IS 1/4 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF WOOD COMPOSITE, HIGH DENSITY PLASTIC OR SIMILAR LOAD BEARING MATERIAL. 7.FOR CONCRETE BLOCK APPLICATIONS DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. 8.INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED IN THE INSTALLATION ANCHOR SCHEDULE ON SHEET 2. TABLE OF CONTENTS SHEET SHEET DESCRIPTION 1 GENERAL NOTES, INSTALLATION NOTES, TABLE OF CONTENTS 2 ANCHOR SCHEDULE - EMBEDMENT AND EDGE DISTANCE 3 NOMINAL 60" x 78" WINDOW ELEVATION & ANCHORING LAYOUT 4 NOMINAL 48" x 96" WINDOW ELEVATION & ANCHORING LAYOUT 5 CROSS SECTIONS - NAILING FIN INSTALLATION 6 CROSS SECTIONS - THRU FRAME INSTALLATION 7 CROSS SECTIONS - SNAP-ON FLANGE THRU FRAME INSTALLATION 8 GLAZING DETAIL AND GLAZING NOTES /BILL OR MATERIALS PERFORMANCE RATING MAXIMUM WINDOW SIZE ELEVATION GLAZING DETAIL (SEE SHEET 8)DESIGN PRESSURE (PSF)IMPACT RATING NOMINAL 48" x 96" (47-5/8" x 95-5/8") SHEET 4 (NOTE 1)A +/- 47 NONE SEE NOTE 6 NOMINAL 48" x 93" (47-5/8" x 92-5/8") SHEET 4 (NOTE 2)A +/- 50 NOMINAL 60" x 78" (59-3/4" x 77-3/4") SHEET 3 (NOTE 1)B +/- 29.7 NOMINAL 60" x 78" (59-3/4" x 77-3/4") SHEET 3 (NOTE 3)A +/-50 NOTES: 1) AS-TESTED WINDOW SIZE AND GLAZING. DESIGN PRESSURES LIMITED BY GLAZING DETAIL. 2) REDUCED HEIGHT WINDOW SIZE TO OBTAIN TESTED DESIGN PRESSURE WITH TESTED GLAZING. ANCHOR QUANTITIES SHOWN ON SHEET 4 WILL BE MAINTAINED. 3) AS-TESTED WINDOW SIZE WITH ENHANCED GLAZING (UPSIZED FROM TEST) TO OBTAIN TESTED DESIGN PRESSURE. RJA8OF12/5/19RWD0002SERIES 8500 VINYL FIXED WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218Robert J. Amoruso, P.E. Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBYPROJECT # 419-0901First IssueEMBEDMENT AND EDGE DISTANCE NAILING FIN FRAME INSTALLATION EMBEDMENT AND EDGE DISTANCE THROUGH-FRAME INSTALLATION EMBEDMENT AND EDGE DISTANCE SNAP-ON FLANGE THROUGH-FRAME INSTALLATION N.T.S.ANCHOR SCHEDULE - EMBEDMENT & EDGE DISTANCE2 RJA8OF12/5/19RWD0002SERIES 8500 VINYL FIXED WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218Robert J. Amoruso, P.E. Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBYPROJECT # 419-0901First IssueOC 5 C 6 C 7 B 5 B 6 B 7 A 5 A 6 A 7 SERIES 8500 VINYL FIXED WINDOW EXTERIOR VIEW (60" X 78" NOMINAL SIZE SHOWN)N.T.S.NOMINAL 60" x 78" WINDOW ELEVATION & ANCHORING LAYOUT3 RJA8OF12/5/19RWD0002SERIES 8500 VINYL FIXED WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218Robert J. Amoruso, P.E. Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBYPROJECT # 419-0901First IssueO B 5 B 6 B 7 C 5 C 6 C 7 A 5 A 6 A 7 SERIES 8500 VINYL FIXED WINDOW EXTERIOR VIEW (48" X 96" NOMINAL SIZE SHOWN)N.T.S.NOMINAL 48" x 96" WINDOW ELEVATION & ANCHORING LAYOUT4 RJA8OF12/5/19RWD0002SERIES 8500 VINYL FIXED WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218Robert J. Amoruso, P.E. Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBYPROJECT # 419-0901First IssueSILL CROSS SECTION NAILING FIN FRAME INSTALLATION5 A JAMB CROSS SECTION NAILING FIN FRAME INSTALLATION5 C EXTERIOR INTERIOR HEAD CROSS SECTION NAILING FIN FRAME INSTALLATION5 B EXTERIOR INTERIOR EXTERIOR INTERIOR N.T.S.CROSS SECTIONS - NAILING FIN INSTALLATION5 RJA8OF12/5/19RWD0002SERIES 8500 VINYL FIXED WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218Robert J. Amoruso, P.E. Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBYPROJECT # 419-0901First IssueEXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR SILL CROSS SECTION THROUGH-FRAME INSTALLATION6 A JAMB CROSS SECTION THROUGH-FRAME INSTALLATION6 C HEAD CROSS SECTION THROUGH-FRAME INSTALLATION6 B N.T.S.CROSS SECTIONS - THRU FRAME INSTALLATION6 RJA8OF12/5/19RWD0002SERIES 8500 VINYL FIXED WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218Robert J. Amoruso, P.E. Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBYPROJECT # 419-0901First IssueSILL CROSS SECTION SNAP-ON FLANGE THROUGH-FRAME INSTALLATION7 A EXTERIOR INTERIOR HEAD CROSS SECTION SNAP-ON FLANGE THROUGH-FRAME INSTALLATION7 A JAMB CROSS SECTION SNAP-ON FLANGE THROUGH-FRAME INSTALLATION7 AEXTERIOR EXTERIOR INTERIOR INTERIOR N.T.S.CROSS SECTIONS - SNAP-ON FLANGE THRU FRAME INSTALL.7 RJA8OF12/5/19RWD0002SERIES 8500 VINYL FIXED WINDOWPTC PRODUCT DESIGN GROUP, LLCPO BOX 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935TITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:RENAISSANCE WINDOWS AND DOORS13340 INTERNATIONAL PARKWAYJACKSONVILLE, FL 32218Robert J. Amoruso, P.E. Florida P.E. No. 49752 Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comREVDESCRIPTIONDATEBYPROJECT # 419-0901First IssueGLAZING DETAIL A GLAZING DETAIL B NOTES: 1.A MINIMUM OF TWO (2) NEOPRENE SETTING BLOCKS WITH 70 TO 90 SHORE A DUROMETER HARDNESS ARE REQUIRED AT BOTTOM (SILL) OF GLAZING LITES MORE THAN 3 FEET IN WIDTH. 2.AS-TESTED IGU SYSTEM SHOWN. OTHER SUBSTITUTES ARE ALLOW WHILE MAINTAINING INDIVIDUAL LITE THICKNESS AND TEMPER. SEE SHEET 1 FOR DETAILS RELATED TO WINDOW SIZE / GLAZING DETAIL / DESIGN PRESSURE.N.T.S.GLAZING DETAILS AND NOTES / BILL OF MATERIALS8