CIV23-001 ABCC Renovation_C-5.01 Rev. 2-7-24_15'X5' TREE WELLS
162 L
F
O
F
2
4"
R
C
P
@ S. =
0.
1
2
%
YD-1
15" H
D
P
E
D
R
AI
N
W/DR
O
P I
N
G
R
A
T
E
@ EL.
=
8.
0
0
INV. E
L.
=
4.
3
0
96 LF
O
F
1
5"
H
D
P
E
@ S.=
0.
3
1
%ATLANTIC BEACH DRIVE (50' R/W)ATLANTIC BEACH COUNTRY CLUB UNIT 1P.B. 67, PGS. 52-54PHASE 1PHASE 2
PHASE 1PHASE 2SYD-4 (EXIST.)
15" HDPE DRAIN
W/DROP IN GRATE
@ EL.=8.50
INV. EL.=3.50
CH-8 (EXIST.)
TYPE "E" INLET
GRATE EL. = 8.50
INV. EL. = 3.25 (18")INV. EL. = 4.40 (12")INV. EL. = 2.75 (24")
EXIST. 34 LF OF 15" ADS
@ S. = 0.29%
YD-5 (EXIST.)
15" HDPE DRAIN
W/DROP IN GRATE
@ EL.=8.00
INV. EL.=4.50
76 LF OF 18" ADS
@ S. = 0.20%
CH-7
TYPE "E" INLET
GRATE EL. = 8.60
INV. EL. = 3.40 (18")
INV. EL. = 3.65 (15")
CH-5 (EXIST.)
TYPE "E" INLET
GRATE EL. = 7.00
INV. EL. = 2.05 (24")
INV. EL. = 1.55 (30")
CH-4 (EXIST.)
TYPE "E" INLET
GRATE EL. = 7.00
INV. EL. = 2.25 (24")
INV. EL. = 3.25 (15")EXIST. 60 LF OF 24" RCP
@ S. = 0.33%
EXIST. 60 LF OF 30" RCP
@ S. = 0.17%
CH-6 (EXIST.)TYPE "E" INLET
GRATE EL. = 7.00
INV. EL. = 2.45 (24")
INV. EL. = 1.45 (30") (N)
INV. EL. = 0.70 (30") (SE)
120 LF OF 15" ADS
@ S. = 0.21%
UP
EXISTING PARKING
PROPOSED BAG DROP STRUCTURE
(REFER TO ARCHITECTURAL PLANS FOR DETAILS)
EXISTING GOLF CLUB BUILDING
EXISTING GOLF CLUB
BUILDING ADDITION
(SEE ARCHITECTURAL
PLANS FOR DETAILS)
EXISTING HEADWALL
EXISTING POOL
PROPOSED EVENT YARD
(SEE LANDSCAPE PLANS FOR DETAILS)
PROPOSED PATIO ADDITION
(REFER TO ARCHITECTURAL PLANS FOR DETAILS)
PROPOSED ADDITION
(REFER TO ARCHITECTURAL PLANS FOR DETAILS)
EXIST. SANITARY
SEWER SERVICE
C.O.
TOP EL. = 9.00
INV. EL. = 5.82
26 LF ~ 4" PVC @ 1.00% SLOPE
EXIST. FIRE MAIN
EXIST. WATER MAIN
EXIST. 24" RCP
TAP INTO EXIST. WATERMAIN
PROVIDE 3/4" POLY STUB TO BAG DROP STRUCTURE
(SEE PLUMBING PLANS FOR CONTINUATION)
TIE INTO EXIST. SANITARY SEWER SERVICE
4"x4" TEE WYE
SANITARY SEWER SERVICE
INV. EL. = 6.10
(SEE PLUMBING PLAN FOR CONTINUATION-
PROVIDE 4"x3" REDUCER AT THE CONNECTION)
14 LF ~ 4" PVC @ 1.00% SLOPE
C.O.
TOP EL. = 9.05
INV. EL. = 5.68
ADJUST EXISTING MAINS TO AVOID
PROPOSED FOUNDATION AS NEEDED
PROPOSED 3/4" POLY
WTAP INTO EXIST. FIRE MAIN SUPPLY LINE -
REFER TO FIRE ENGINEERING PLANS FOR SIZES AND DETAILS
(SEE PLUMBING PLANS FOR CONTINUATION)
NEW FITNESS AREA FIRE SPRINKLER RISER
(SEE PLUMBING PLANS FOR CONTINUATION)
Know what'sbelow.
before you dig.Call
R
7654321
A
B
C
D
E
G:\FLA\Projects\Atlantic Beach Country Club\10876-00 - ABCC Renovation\03 - DWG\01 - Sheets\10876-C501-UTIL.dwg Layout: C-5.01 Plotted: 8/31/2023 1:57:26 PM7654321 DESCRIPTIONREVDATEAPRPROJECT NO.:
DESIGNED BY:
REVIEWED BY:
DRAWN BY:
DATE:
Copyright 2023
C-5.01
10/25/2022JU
MB MB
10876-00UTILITY PLANATLANTIC BEACH COUNTRY CLUB, INC.SCALE: 1" =
0
##
##'####
LEGEND
EASEMENT
PROPERTY BOUNDARY
SILT FENCE
WATER MAIN
SANITARY SEWER
FORCE MAIN
SF SF
NOTES:
1.VARIOUS EXISTING UTILITIES INCLUDING BUT NOT
LIMITED TO WATER, SEWER GRAVITY AND
FORCEMAINS, TELEPHONE, ELECTRICAL, ETC. EXIST
IN PROJECT AREA. CONTRACTOR TO TAKE ALL
PRECAUTIONS NECESSARY TO LOCATE, IDENTIFY,
AND VERIFY ALL UTILITIES PRIOR TO
CONSTRUCTION. CONTRACTOR TO NOTIFY THE
ENGINEER OF ANY CONFLICTS OR DISCREPANCIES
WITH THE PLANS AND ACTUAL FIELD CONDITIONS.
COST ASSOCIATED WITH UTILITY LOCATIONS AND
NECESSARY RELOCATIONS OR ADJUSTMENTS TO
EXISTING SYSTEMS TO BE INCLUDED IN THE
CONTRACTORS BID PRICE. NO ADDITIONAL
PAYMENTS WILL BE MADE.
2.ALL NEW WATER AND SEWER TAPS TO BE
PERFORMED BY UTILITY CONTRACTOR OR LICENSED
MASTER PLUMBER AND MUST BE SCHEDULED 48
HOURS IN ADVANCE THROUGH JEA INSPECTOR.
3.ALL POTABLE WATER PIPE 3" IN DIAMETER OR LESS
SHALL BE N.S.F.P.W. RATED.
4.SEE PLUMBING PLAN FOR CONTINUATION OF ALL
WATER AND SANITARY LINES AT THE BUILDING.
5.ALL ONSITE WATER AND SEWER APPURTENANCES
OUTSIDE OF ROW SHALL BE PRIVATELY OWNED,
OPERATED AND MAINTAINED.
6.FIRE HYDRANT TOPS AND CAPS TO BE PAINTED
ACCORDING TO NFPA 291 CH. 5.
BGE, Inc.
10151 Deerwood Park Blvd,
Bldg. 200, Ste. 200
Jacksonville, FL 32256
Tel: 904-323-0727 ▪ www.bgeinc.com
FL Registry No. 32116
CONSTRUCTION DOCUMENTSATLANTIC BEACH COUNTRY CLUBPHASE 1SD PRICING123DD PRICING90% CD12-02-2202-10-2303-30-23STATE OF
L I C ENSE
FLOR I D APROF
E
SSIONA L E N G INEERJENN IF E R B.UR
C
ANNo 74544
THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED
BY JENNIFER B. URCAN. FLORIDA LICENCE NUMBER 74544 ON
DATE AND/OR TIME SHOWN USING A DIGITAL SIGNATURE.
PRINTED COPIES ON THIS DOCUMENTS ARE NOT CONSIDERED
SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.4PHASE 2 90% CD09-01-23