1470 Ocean Blvd ROOF24-0023 PermitOWNER:ADDRESS:CITY:STATE:ZIP:
SAAS REBECCA LYNN 11114 CRIPPLEGATE RD PETOMAC MD 20854
COMPANY:ADDRESS:CITY:STATE:ZIP:
FORD ROOFING SYSTEMS
INC 3839 Millpoint Drive Jacksonville FL 32257
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
171855 0000 MANDALAY
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1470 OCEAN BLVD ROOF NON SHINGLE METAL ROOF $5000.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 BUILDING BUILDING INFORMATIONAL
Notes:
NOTICE OF COMMENCEMENT
2 BUILDING NOTICE OF COMMENCEMENT INFORMATIONAL
Notes:
No inspections may be scheduled until a copy a recorded Notice of Commencement has been submitted to the Building Department
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 4/9/2024
PERMIT NUMBER
ROOF24-0023
ISSUED: 4/9/2024
EXPIRES: 10/6/2024
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $80.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $124.00
3 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL
Notes:
a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. All roofing projects require an In-
Progress Inspection. Sheathing installation and replacement guidelines per APA. Underlayment must conform to FBC-R Table 905.1.1. Shingles must
conform to ASTM D3161 G or H, or ASTM D7158
2 of 2Issued Date: 4/9/2024
PERMIT NUMBER
ROOF24-0023
ISSUED: 4/9/2024
EXPIRES: 10/6/2024
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing Dry-In
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before
any work is covered up.
* When all gas piping is complete and wallboard is installed but before
gas is attached to any appliance. All outlets must be capped and pipe
pressurized at a minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department - Phone: 904-247-5826 - Email: Building-Dept@coab.us
Public Works/Utilities - Phone: 904-247-5834
Fire Department - Phone: 904-630-4789
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are
complete, but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
James L. Buckner, P.E.
FL31242
Date: 2023.10.17
'11:05:47 -04'00
Specialty Structural Engineering
CBUCK, Inc. dba CBUCK Engineering
Phone: (561) 491-9927 · Email: cbuck@cbuckinc.net · Website: www.cbuckinc.net
Business: 1374 Community Dr., Jupiter, FL 33458
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Evaluation Report
“Sentrigard SL175”
Metal Roof Assembly
Manufacturer:
NB Handy Company
65 10th Street
Lynchburg, VA 24504
800-284-6242
for
Florida Product Approval
# FL 40560.1 R3
Florida Building Code 8th Edition (2023)
Method: 1 - D
Category: Roofing
Sub - Category: Metal Roofing
Product: “Sentrigard SL175” Roof Panel Material: Aluminum
Panel Thickness: 0.032”
Panel Width: 2” - 16”
Panel Seam: Snap-Lock Support: Wood Deck
Prepared by:
James L. Buckner, P.E., SECB
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 23-541-SL175-A3W-ER.2
(Revises 20-295-SL175-A3W-ER, 40560.1 R2)
Date: 10/17/2023
Contents:
Evaluation Report Pages 1 – 7
FL #: FL 40560.1 R3
Date: 10/17/2023
Report No.: 23-541-SL175-A3W-ER.2
Page 2 of 7
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Manufacturer: NB Handy Company
65 10th Street
Lynchburg, VA 24504
800-284-6242
http://www.nbhandycom/
Product Name: “Sentrigard SL175”
Product Category: Roofing
Product Sub-Category Metal Roofing
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product/System
Description:
“Sentrigard SL175” Roof Panel
0.032” Aluminum Snap-Lock roof panel mechanically attached to Wood Deck with
fixed panel clips & screws.
Product Assembly as
Evaluated:
Refer to Page 4 of this report for product assembly components/materials &
standards:
1. Roof Panel
1. Panel Clip
2. Fasteners
3. Panel Adhesive
4. Ice & Water Shield
5. Cover Board (Optional)
6. Insulation (Optional)
7. Underlayment
Support: Type:
Wood Deck
(Design of support system is outside the scope of this evaluation.)
Description:
• 19/32” or greater plywood,
• or Wood plank (min. specific gravity of 0.42)
Slope: Minimum slope shall be: 2 : 12 or greater
In compliance with FBC Chapter 15 based on the type of roof covering, applicable
code sections and in accordance with manufacturer’s recommendations.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure:
(Refer to “Table A” attachment details herein)
Refer to Table A
FL #: FL 40560.1 R3
Date: 10/17/2023
Report No.: 23-541-SL175-A3W-ER.2
Page 3 of 7
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Performance
Standards:
Standards Equivalency:
The product described herein has demonstrated compliance with:
• UL 580-06 – Test for Uplift Resistance of Roof Assemblies
• UL 1897-15 – Uplift test for roof covering systems
• TAS 125-03 – Standard Requirements for Metal Roofing Systems
The UL 1897-12 standard version used to test the evaluated product assembly is
equivalent with the prescribed standards in UL 1897-15 adopted by the Florida
Building Code 8th Edition (2023) for use as evaluated in this report.
Code Compliance: The product(s) described herein have demonstrated compliance with the
performance standards listed above as referenced in the:
Florida Building Code 8th Edition (2023)
International Building Code 2021
Evaluation Report
Scope:
This product evaluation is limited to compliance with the structural requirements
of the Florida Building Code, as related to the scope section to Florida Product
Approval Rule 61G20-3.001.
Limitations and
Conditions of Use: • Scope of “Limitations and Conditions of Use” for this evaluation:
This evaluation report for “Optional Statewide Approval” contains technical
documentation, specifications and installation method(s) which include
“Limitations and Conditions of Use” throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under “Optional Statewide Approval”.
• All metal components and fasteners shall be corrosion resistant in accordance
with applicable sections of FBC, including but not limited to Sections 1504.3.2,
1506.6 and 1507.4.4.
• Deck shall be in compliance with applicable building code.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3 and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties).
• Option for application outside “Limitations and Conditions of Use”
Rule 61G20-3.005(1)(e) allows engineering analysis for “project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code”. Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the responsibility
of others.
Quality Assurance:
The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA
1824).
FL #: FL 40560.1 R3
Date: 10/17/2023
Report No.: 23-541-SL175-A3W-ER.2
Page 4 of 7
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Components/Materials
(by Manufacturer):
Components &
Materials:
(by Others)
Roof Panel: Sentrigard SL175
Material:
Thickness:
Panel Widths:
Rib Height:
Alloy Type:
Corrosion Resistance:
Aluminum
0.032” (min.)
2” - 16” (max.) Coverage
1-3/4”
3105-H14 (in compliance with ASTM B 209)
Per FBC Section 1507.4.3
Roof Panel Clip: SL175 Clip
Type:
Material:
Thickness:
Yield Strength:
Dimensions:
Corrosion Resistance:
One-piece, fixed clip
Galvanized Steel
18 Gauge min.
40 ksi min.
1.875” (tall) x 3.75” (long)
Per FBC Section 1506.7
Fastener:
Type:
Size:
Corrosion Resistance:
Standard:
Low Profile Pancake-Head Wood Screw
#14-13 x penetrate thru support deck 3/16"
Minimum
Per FBC 1506.6 & 1507.4.4
Per ANSI/ASME B18.6.1
Steel Strap (Required with Method 3):
Material:
Thickness:
Dimensions:
Galvanized Steel
24 Gauge min.
4-1/2” x ¾”
Panel Adhesive/Sealant (Required with Method 3):
Product Name:
Type:
Application Size:
Application Location:
Titebond Metal Roof Weathermaster Sealant
One component, elastomeric polymer
3/8” continuous bead
along each side of panel steel strap
Ice & Water Shield (Tested):
Type:
Standard:
Ice & Water Shield
ASTM D4869 Type III or IV
Cover Board (Optional):
Any ½” min. approved coverboard with current approval.
Insulation (Optional):
Type:
Thickness:
Compressive Strength:
Rigid Insulation Board
3” (max.)
20 psi min.
Insulation shall comply with FBC Section 1508. When insulation is incorporated,
fastener length shall conform to penetrate thru bottom of support a minimum of
3/16”.
Underlayment:
Material and application all be in compliance with FBC Section 1507.1.1 and in
accordance with applicable code sections and manufacturer’s recommendations.
FL #: FL 40560.1 R3
Date: 10/17/2023
Report No.: 23-541-SL175-A3W-ER.2
Page 5 of 7
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Installation:
Installation Method:
(Refer to “TABLE A” below and drawings at the end of this evaluation report.)
Clip Spacing: Refer to “TABLE A” Below
(along the length of the panel)
Two (2) fasteners per Clip
Rib Interlock: Snap-Lock
(Panel ribs shall be fully engaged to form an integral snap-lock.)
Steel Strap: Per Table A Below
(layered below the center of each panel
Panel adhesive: Per Table A Below
(3/8” bead applied on each side of steel strap)
Minimum fastener penetration thru bottom of support, 3/16”.
For panel construction at the end of panels, refer to manufacturer’s
instructions and any site specific design.
TABLE “A” ALLOWABLE LOADS
“Sentrigard SL175” (.032” Aluminum) Roof Panel attached to Wood Deck
# Panel Width
(max.)
Deck Thickness
(min.)
Panel Clip Clip Spacing
(max.)
# of Fasteners
per Clip
Panel Adhesive Panel Seam
(min.)
Design Pressure
(ASD)
1 16” 19/32” 3.75” Fixed 24” 2 NO SnapLock - 71 PSF
2 16” 19/32” 3.75” Fixed 12” 2 NO SnapLock - 133.4 PSF
3 16” 19/32”
3.75” Fixed
w/Steel
Strap
12” 2 YES SnapLock - 168.5 PSF
Note: Allowable design pressure(s) for allowable stress design (ASD).
Install the “Sentrigard SL175” roof panel assembly in compliance with the
installation method listed in this report and applicable code sections of FBC 8th
Edition (2023). The installation method described herein is in accordance with
the scope of this evaluation report. Refer to manufacturer’s installation
instructions as a supplemental guide for attachment.
Referenced Data:
Other Tests
(Not Part of This
Evaluation Report):
1. TAS 125 Uplift Test (Per UL580-06 and UL 1897-12) & ASTM E8
By Farabaugh Engineering & Testing, Inc. (FBC Organization ID# TST 1654)
Report No. T226-21, Specimens #1-4, Date: 08/25/21
2. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID# QUA 1824)
NB Handy Company Licensee #420
3. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
1. TAS 100-95 Wind Driven Rain Test
By Farabaugh Engineering & Testing, Inc. (FBC Organization ID# TST 1654)
Report No. T233-21, Date: 08/30/21
FL #: FL 40560.1 R3
Date: 10/17/2023
Report No.: 23-541-SL175-A3W-ER.2
Page 6 of 7
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Installation Method
NB Handy Company
“Sentrigard SL175” (0.032” Aluminum) Roof Panel attached to Wood Deck
Typical Panel Profile
(2” – 16” max. width)
Typical Panel Clip
Steel Strap
FL #: FL 40560.1 R3
Date: 10/17/2023
Report No.: 23-541-SL175-A3W-ER.2
Page 7 of 7
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Installation Method
NB Handy Company
“Sentrigard SL175” (0.032” Aluminum) Roof Panel attached to Wood Deck
Typical Panel Clip Assembly View
(Method 1 & 2)
Typical Panel Clip Assembly View
(Method 3)