Loading...
1169 E LINKSIDE CT MCRS24-0004 Wrye Residence Sealed_Part1 REV.3-28-24REVSHEET NAMESHEET SIZESHEET NUMBERWRYE RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEG-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1169 LINKSIDE CT E, ATLANTIC BEACH, FL 32233 1060 MAITLAND CENTER COMMONS,SUITE 270,MAITLAND, FL 32751TEL:(407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590CODES AND STANDARDS1169 LINKSIDE CT E,ATLANTIC BEACH, FL 32233WRYE RESIDENCEVICINITY MAPSHEET INDEXG-01COVER SHEETPROJECT SITEPROJECT DESCRIPTION:OWNERHOUSE PHOTOA-01ROOF PLANS-01MODULE LAYOUTS-02ATTACHMENT DETAILS-02.1STRUCTURE CALCULATIONE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGDS-01-07DATA SHEETSSHEET SHEET DESCRITIONCOVER SHEETA-00NOTES AND DESCRIPTIONELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION:INSTALLERENGINEERWRYE, WALTER15x410 HANWHA: Q.PEAK DUO BLK ML-G10+ (410W)MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESSYSTEM SIZE:6.150 kW DC STC - 5.235 kW ACARRAY AREA #1:316.81 SQ. FT.DESIGN CRITERIA:WIND SPEED (ULT): 130 MPHWIND SPEED (ASD): 101 MPHRISK CATEGORY:IIEXPOSURE:BSNOW LOAD: 4.0 PSFA1A SOLAR CONTRACTING10418 New Berlin Road, Unit #223Jacksonville, FL 32226PH: (904) 683-8316PROJECT SITE6.150 kW DC STC - 5.235 kW AC PV SYSTEMCastillo Engineering Services LLC1060 Maitland Center Commons, Suite 270, Maitland, FL 32751TEL: (407) 289-2575Ermocrates E. CastilloLicense#: FL PE 52590REVDESIGNERDATECOMMENTSRACKING: IRONRIDGE XR100ATTACHMENT: IRONRIDGE HUGGOVERNING CODES:FLORIDA RESIDENTIAL CODE, 8TH EDITION 2023 (FRC)FLORIDA PLUMBING CODE, 8TH EDITION 2023 (FPC)FLORIDA BUILDING CODE, 8TH EDITION 2023 (FBC)FLORIDA MECHANICAL CODE, 8TH EDITION 2023 (FMC)NATIONAL ELECTRICAL CODE 2020 (NEC)ASCE 7-22FLORIDA FIRE PREVENTION CODE, 8TH EDITION 2023(FFPC)I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2023 8th ED.,CHAPTER 3. BUILDING STRUCTURE WILL SAFELYACCOMMODATE WIND LATERAL AND UPLIFTFORCES, AND EQUIPMENT DEAD LOADS.I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICALCOMPONENTS ARE DESIGNED AND APPROVED USINGTHE STANDARDS CONTAINED IN THE MOST RECENTVERSION OF THE FLORIDA BUILDING CODE. FBC 20238th ED, SECT. 107, THE NEC 2020, AND THOSE SETFORTH BY THE FLORIDA SOLAR ENERGY CENTERCERTIFICATION.EQUIPMENT SUMMARY15 HANWHA: Q.PEAK DUO BLK ML-G10+ (410W) MODULES15 ENPHASE: IQ8A-72-2-US MICROINVERTERSDigitallysigned by:Ermocrates E CastilloDate:2024.02.1411:29:17 System DescriptionThis system is a grid-tied, PV system, with PV generation consisting of15x410 HANWHA: Q.PEAK DUO BLK ML-G10+ (410W) Modules with a combinedSTC rated DC output power of 6,150W. The modules are connected into 15ENPHASE: IQ8A-72-2-US Microinverters with a combined AC output power of5,235W. The inverter has electronic maximum power point tracking to maximizeenergy captured by the PV modules. The inverter also has an internal ground faultdetection and interruption device that is set to disconnect the array in the eventthat a ground fault that exceeds one ampere should occur. The inverter has DC andAC disconnect integrated system and labels are provided as required by theNational Electrical Code.When the sun is shining, power from the PV array is fed into the inverter,where it is converted from DC to AC. The inverter output is then used to contributeto the power requirements of the occupancy. If PV power meets the requirementsof the loads of the occupancy, any remaining PV power is sold back to the utility.When utility power is available, but PV power is not available, building loads aresupplied by the utility.The inverter meets the requirements of IEEE 1547 and UL 1741.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxFigure 1: PV System Block DiagramSection..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........AC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBACDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberVent, Attic fan(Roof obstruction)PV Roof AttachmentTrussesConduitFire AccessAC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCB Combiner BoxDC Direct CurrentACD AC DisconnectDISC Disconnect(E) ExistingEL ElevationEQ EqualJB Junction BoxMCB Main Combiner BoxMFR ManufacturerMIN MinimumMISC Miscellaneous(N) NewOCPD OverCurrent Protection DevicePOCC Point Of Common CouplingPV PhotovoltaicSF Squarefoot/feetSTC Standard Test ConditionsTBD To Be DeterminedTYP TypicalUNO Unless Noted OtherwiseVIF Verify In FieldWP Weather ProofBatteryBATUtility meterUMGPGeneration PanelMDPMain Distribution PanelSoladeckSDNAVD North American Vertical datumMID Microgrid Interconnect Device REVSHEET NAMESHEET SIZESHEET NUMBERWRYE RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-00CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1169 LINKSIDE CT E, ATLANTIC BEACH, FL 32233 1060 MAITLAND CENTER COMMONS,SUITE 270,MAITLAND, FL 32751TEL:(407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590NOTES ANDDESCRIPTIONSymbols:Abbreviations:74.0"41.10"RAILS IN THISPOSITION UNOFALL PROTECTION:ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENTMUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT ORSUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDSPER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:·AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICHMAINTAINS A SAFETY FACTOR OF AT LEAST TWO.·UNDER THE SUPERVISION OF A QUALIFIED PERSONADDITIONAL INFORMATION·29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.·1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES·1926.502(D)(15)ALLOWABLE/DESIGN PRESSUREPSFDOWN PRESSURE75UPLIFT PRESSURE, 2 RAILS55HANWHA:Q.PEAK DUO BLKML-G10+ (410W)MODULESDigitallysigned by:Ermocrates E CastilloDate:2024.02.1411:29:17 103'-0"50'-3"103'-0"50'-3"11'-8"10'-6"UMACDCBMDPSD4'-10"3'-3"ROOF PLANREVSHEET NAMESHEET SIZESHEET NUMBERWRYE RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1169 LINKSIDE CT E, ATLANTIC BEACH, FL 32233 1060 MAITLAND CENTER COMMONS,SUITE 270,MAITLAND, FL 32751TEL:(407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590A-01SCALE: 1/8" = 1'-0"1ROOF PLAN WITH FIRE SETBACKSAND PROPERTY LINESIN 3/4" PVC ,EMT, FMC, LFMC, OREQUIVALENT CONDUIT RUNA-011ROOF PLAN WITH FIRE SETBACKSAND PROPERTY LINESLINKSIDE CT E,1-STORYHOUSEEXISTINGDRIVEWAYROOF #1(15) HANWHA: Q.PEAK DUO BLK ML-G10+(410W) MODULES(E) SERVICE POINT AND UTILITY METERING(N) (15) ENPHASE: IQ8A-72-2-USMICROINVERTERSFIRE ACCESS AND PATHWAYS AS PERNFPA 1,11.12.3.2 OR FFPC,11.12.3.2(N) "JEA" ALTERNATIVE POWER SOURCEAC DISCONNECT/ RAPID SHUTDOWN(N) ENPHASE IQ COMBINER BOX3'-0" RIDGE1'- 6 " E . W .(N) SOLADECK(E) MAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANEL3'-0" RAKEDigitallysigned by:Ermocrates E CastilloDate:2024.02.1411:29:17 81'-0"42'-2"4'-0"(TYP.)REVSHEET NAMESHEET SIZESHEET NUMBERWRYE RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1169 LINKSIDE CT E, ATLANTIC BEACH, FL 32233 1060 MAITLAND CENTER COMMONS,SUITE 270,MAITLAND, FL 32751TEL:(407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590MODULE LAYOUTS-01SCALE: 3/32" = 1'-0"1MODULE LAYOUTMODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 15 MODULESMODULE TYPE = HANWHA: Q.PEAK DUO BLK ML-G10+ (410W)MODULESMODULE WEIGHT = 48.50 LBS / 22.0 KG.MODULE DIMENSIONS = 74.0" x 41.10" = 21.12 SFUNIT WEIGHT OF ARRAY = 2.30 PSFGENERAL INSTALLATION PLAN NOTES:1) STRUCTURE PROPERTIES·ROOF FINISH: SHINGLE ROOF·MEAN ROOF HEIGHT: 15 FT·ROOF SLOPES: 30.0°·PRE-ENGINEERED TRUSSES·WOOD SPECIES: SYP·TRUSS SIZE: 2"X4"·TRUSSES SPACING: 24" O.C.·ROOF SHEATHING: 7/16” OSB2) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED ASSHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:ARRAY AREA & ROOF AREA CALC'SROOFROOF TYPENO. OFMODULESARRAYAREA(sq.Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZETRUSSESSPACING#1ASPHALT SHINGLE15316.81802.1939.4930.0°173°2"X4"24" o.c.TOTAL PLAN VIEW15316.812703.0011.72(E) FRONT YARD (E) BACK YARDROOF #1TILT - 30.0°AZIM. - 173°(30) PV ROOF ATTACHMENT@ 72" O.C. MAX.(SEE SHEET S-02 FORATTACHMENT DETAIL)(N) IRONRIDGE XR-100 RAIL(N) (15) ENPHASE: IQ8A-72-2-USMICROINVERTERSLEGEND- WIND ZONE 1 (TYP)- WIND ZONE 2 (TYP)- WIND ZONE 3 (TYP)- WIND ZONE 1' (TYP)WINDZONESNON-EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 16' - 0"1' - 4"6' - 0"1' - 4"ZONE 1'XXXXZONE 26' - 0"1' - 4"6' - 0"1' - 4"ZONE 36' - 0"1' - 4"6' - 0"1' - 4"SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS.3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18" EACHWAY FROM HIPS AND VALLEYS PER NFPA1,11.12.3.2 OR FFPC,11.12.3.2.4) THE EXISTING ROOF AND STRUCTURE IS IN GOOD CONDITION ANDWILL NOT BE ADVERSELY AFFECTED BY THE ADDITIONAL LOADSIMPOSED BY THE PV INSTALLATION. THE INSTALLER OR CONTRACTORIS TO FIELD VERIFY AND REPORT TO THE ENGINEER IF THERE ARE ANYDISCREPANCIES BETWEEN THE PLANS AND IN FIELD CONDITIONS.5) ANY MODULE THAT IS PLACED MORE THAN 0.5 TIMES THE HEIGHT OFTHE BUILDING (0.5h), (AS SHOWN ON S-02) FROM THE EDGE OF THEBUILDING, OR MORE THAN 4FT FROM ANOTHER MODULE, WILL BETREATED AS EXPOSED (ASCE 7-22, CHAPTER 29).6) ANY MODULE THAT IS WITHIN A BOUNDARY OF 2 TIMES THE HEIGHTOF THE MODULE FROM THE ROOF, TO EDGE OF THE BUILDING (2h2, ASSHOWN ON S-02), WILL BE CONSIDERED EXPOSED (ASCE 7-22,CHAPTER 29).* I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2023 8TH ED., CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERALAND UPLIFT FORCES AND EQUIPMENT DEAD LOADS.Digitallysigned by:Ermocrates E CastilloDate:2024.02.1411:29:17 6"REVSHEET NAMESHEET SIZESHEET NUMBERWRYE RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1169 LINKSIDE CT E, ATLANTIC BEACH, FL 32233 1060 MAITLAND CENTER COMMONS,SUITE 270,MAITLAND, FL 32751TEL:(407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590ATTACHMENT DETAIL(E) ASPHALT SHINGLE ROOF2ATTACHMENT DETAIL (ENLARGED VIEW)S-02SCALE:1' = 1'-0"MODULE MID/END CLAMPSOLAR MODULE(E) ROOF SHEATHINGATTACHMENT DETAILS-02SCALE: 1' = 1'-0"1(E) 2"X4" SYP TRUSSES @ 24" O.C.IRONRIDGE HUGIRONRIDGE XR100 RAILGROUNDING MID/END CLAMP(E) 2"X4" SYP TRUSSES @ 24" O.C.2"X4" SYP TRUSS SPANNERFOR MISSED TRUSSATTACHMENT (IF REQUIRED)h₂SEE (2/S-02) FORENLARGED VIEWSOLAR MODULEAVOID PLACING HUG ATTACHMENTSDIRECTLY OVER SHINGLE KEYWAYS ORBUTT JOINTS. IF THEY CANNOT AVOIDED,FILL BUTT JOINT OR KEYWAY FROM THETOP EDGE OF THE ATTACHMENT UP TOSHINGLE COURSE ABOVE WITH APPROVEDSEALANT.REMOVE RELEASE LINER FROMBOTTOM OF HUG ATTACHMENTS BEFOREINSTALLING. DO NOT APPLY SEALANT TOBOTTOM SURFACE OF HUG ATTACHMENTSPV MODULE FRAMEIRONRIDGE XR100 RAILIRONRIDGE UNIVERSALFASTENING OBJECTPV MODULE FRAMEIRONRIDGE XR100 RAILIRONRIDGE STOPPER SLEEVEIRONRIDGE UNIVERSALFASTENING OBJECT3DETAIL, MID CLAMP FRONTS-02Scale: 6"=1'-0"4DETAIL, END CLAMP (UFO) FRONTS-02Scale: 6"=1'-0"#14 X 3" MIN. EMBEDMENTRD STRUCTURAL WOOD SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMING#14 X 3" MIN. EMBEDMENTRD STRUCTURAL WOOD SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMINGhDISTANCE : 15'2h2DISTANCE : 1'-0"0.5hDISTANCE : 7'-6"Digitallysigned by:Ermocrates E CastilloDate:2024.02.1411:29:18 REVSHEET NAMESHEET SIZESHEET NUMBERWRYE RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1169 LINKSIDE CT E, ATLANTIC BEACH, FL 32233 1060 MAITLAND CENTER COMMONS,SUITE 270,MAITLAND, FL 32751TEL:(407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590STRUCTURECALCULATION(2) #14 X3" MIN.EMBEDMENTRD STRUCTURAL WOOD SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMINGDigitallysigned by:Ermocrates E CastilloDate:2024.02.1411:29:18 REVSHEET NAMESHEET SIZESHEET NUMBERWRYE RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1169 LINKSIDE CT E, ATLANTIC BEACH, FL 32233 1060 MAITLAND CENTER COMMONS,SUITE 270,MAITLAND, FL 32751TEL:(407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590ELECTRICALLINE DIAGRAMSOLAR ARRAY (6.150 kW DC STC - 5.235 kW AC)(15) HANWHA: Q.PEAK DUO BLK ML-G10+ (410W) MODULES(01) BRANCH OF 08 MODULES &(01) BRANCH OF 07 MODULESQ CABLESL2L1NL2L1GN20A/2PGG(N) SOLADECK600V, NEMA 3RUL LISTEDGGGGGGGG#6 BARE CU WIRE PROTECTED PER NEC 250.64(B)FACTORY INSTALLEDBREAKER FOR IQ GATE WAY(N) 125A ENPHASE IQ COMBINER 4/4C(X-IQ-AM1-240-4) OR (X2-IQ-AM1-240-4C) [WITHUPTO (4) 2-POLE BREAKERS, IQ GATEWAY ANDINTEGRATED LTE-M1 CELL MODEM]Q.PEAK DUO BLK ML-G10+(410W) MODULESENPHASE: IQ8A-72-2-USMICROINVERTERSGGGGGGGL2L120A/2P1ELECTRICAL LINE DIAGRAMSCALE: NTSE-01NOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2020, AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION,INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUMNUMBER OF MODULES PER STRING, MAXIMUM OUTPUT,MODULE MANUFACTURER AND MODEL NUMBER, INVERTERMANUFACTURER AND MODEL NUMBER, AS APPLICABLE.2. THE SOLAR PV BACKFED BREAKER IS LOCATED AT THE ENDOF THE BUSBAR AND THERE IS NO LUG FED SUB PANEL.L2L1L2L1NNGG(N) "JEA" ALTERNATIVE POWERSOURCE AC DISCONNECT/RAPID SHUTDOWN:240V, 60AMP RATED,NEMA 3R, UL LISTEDLOCKABLE & NON-FUSIBLETO UTILITY GRIDL2L1L2L1L2L1L1L2NL1L2NN(E) BI-DIRECTIONALSERVICE POINT ANDUTILITY METERING1-PHASE, 240VL2L1L2L1L2L1(E) MAIN BREAKER200A/2P, 240VGEXISTING GROUNDINGELECTRODE SYSTEML1L2N(E) MAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANEL,200A RATED, 240VINTERCONNECTION120% RULE - NEC 705.12(B)(3)(2)UTILITY FEED + SOLAR BACKFEED200A + 40A = 240ABUSS RATING x 120%200A x 120% = 240A40A/2P(2) #10 AWG THWN-2 – RED(2) #10 AWG THWN-2 – BLACKEGC #6 AWG THWN-2 GNDIN 3/4" PVC, IMC, RMC,LFMC, RTRC, LFNC, EMTOR FMT CONDUIT RUN(3) #6 AWG THWN-2(1) #8 AWG THWN-2 GNDIN 3/4" PVC, IMC, RMC,LFMC, RTRC, LFNC, EMTOR FMT CONDUIT RUNDigitallysigned by:Ermocrates E CastilloDate:2024.02.1411:29:18 REVSHEET NAMESHEET SIZESHEET NUMBERWRYE RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1169 LINKSIDE CT E, ATLANTIC BEACH, FL 32233 1060 MAITLAND CENTER COMMONS,SUITE 270,MAITLAND, FL 32751TEL:(407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590WIRING CALCULATIONSELECTRICAL CALCULATIONELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELEDFOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TOTHE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICALEQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES ANDSTANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARENOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FORUSE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).17.THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PVCONDUCTORS IN COMPLIANCE WITH NEC 690.12.18.LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWNON SHEET E-03.19.ALL CONDUITS TO BE INSTALLED A MIN OF 7/8" ABOVE THE ROOFSURFACE.I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICALCOMPONENTS ARE DESIGNED AND APPROVED USINGTHE STANDARDS CONTAINED IN THE MOST RECENTVERSION OF THE FLORIDA BUILDING CODE. FBC 20238th ED, SECT. 107, THE NEC 2020, AND THOSE SETFORTH BY THE FLORIDA SOLAR ENERGY CENTERCERTIFICATIONDigitallysigned by:Ermocrates E CastilloDate:2024.02.1411:29:18