381 SEMINOLE RD RESA24-0006 Archs DwgsSEMINOLE DRIVEPROPERTY LINE 100.00'PROPERTY LINE50.00'PROPERTY LINE 100.00'PROPERTY LINE50.00'SITE PLAN1SCALE: 1/8" = 1'-0"N20'-0" FRONT 20'-0" REAR7'-6"7'-6"NOTES: (FBC 2020-R)1. DRAFT STOPPING TO BE INSTALLED AS REQUIRED PER FBC R-3022.12: "IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OFA FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THECONCEALED SPACE DOES NOT EXCEED 1,000 SF."2. DWELLING/GARAGE FIRE SEPARATION TO BE PER FBC R-302.6: "NOT LESS THAN 12" THICK GYPSUMBOARD OR EQUIVALENT APPLIED TO GARAGE SIDE."3. OPENING PROTECTION FOR DOOR BETWEEN GARAGE AND RESIDENCE TO BE PER FBC R-302.5.1:"OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOODDOORS NOT LESS THAN 1 38" IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN1 38" THICK, OR 20-MINUTE FIRE-RATED DOORS."4. ATTIC ACCESS TO BE SIZED PER FBC R-807.1: "THE ROUGH-FRAMED OPENING SHALL NOT BE LESSTHAN 22"X30" AND SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION."5. ALL BATHROOM SHOWER ENCLOSURES TO HAVE SAFETY GLAZING IN COMPLIANCE WITH FBCR-308.4.5.6. WHERE GLAZING ADJACENT TO STAIRS IS LESS THAN 36" ABOVE THE WALKING SURFACE, SAFETYGLAZING WILL BE PROVIDED PER FBC R- 308.4.6.7. DOOR BETWEEN RESIDENCE AND GARAGE WILL BE SELF-CLOSING PER FBC R-302.5.1.NOTES: (FBC 2020-R)4. FBC R-703.7.3 - WATER RESISTIVE BARRIERS - WATER RESISTIVE BARRIERS SHALL BE INSTALLED ASREQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED SHEATHING, SHALL INCLUDE AWATER RESISTIVE VAPOR PERMEABLE BARRIER WITH A PERFORMANCE TEST AT LEAST EQUIVALENT TOTWO LAYERS OF GRADE D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCHTHAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED INACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER RESISTIVE BARRIER ISDIRECTED BETWEEN THE LAYERS. EXCEPTION: WHERE THE WATER RESISTIVE BARRIER THAT IS APPLIEDOVER WOOD BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER THAN THAT OF A60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO BY AN INTERVENING,SUBSTANTIALLY NONWATER-ABSORBING LAYER OR DESIGNED DRAINAGE SPACE.5. FBC R-M1305.1 - APPLIANCE ACCESS FOR INSPECTION SERVICE, REPAIR AND REPLACEMENT -"APPLIANCES" SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND REPLACEMENT WITHOUTREMOVING PERMANENT CONSTRUCTION, OTHER "APPLIANCES" OR ANY OTHER PIPING OR DUCTS NOTCONNECTED TO THE "APPLIANCE" BEING INSPECTED, SERVICED, REPAIRED OR REPLACED. A LEVELWORKING SPACE NOT LESS THAN 30" DEEP AND 30" WIDE SHALL BE PROVIDED IN FRONT OF THECONTROL SIDE TO SERVICE THE APPLIANCE.1. FBC R-302.5.1 - OPENING PROTECTION: OPENINGS FROM A PRIVATE GARAGE DIRECTLY TO A ROOMUSED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGEAND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 38" INCHES INTHICKNESS, SOLID OR HONEYCOMB-CORE STEEL DOORS NOT LESS THAN 1 38" THICK, OR 20-MINUTEFIRE-RATED DOORS.2. FBC R-302.5.2 - DUCT PENETRATION: DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS ORCEILINGS SEPARATING THE "DWELLING" FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO.26 GAGE SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OROTHER "APPROVED" MATERIAL AND SHALL NOT HAVE OPENINGS INTO THE GARAGE.3. FBC R-302.6 - DWELLING-GARAGE FIRE SEPARATION: THE GARAGE SHALL BE SEPARATED ASREQUIRED BY TABLE R302.6. OPENINGS IN GARAGE WALLS SHALL COMPLY WITH SECTION R302.5.ATTACHMENT OF GYPSUM BOARD SHALL COMPLY WITH TABLE R702.3.5. THE WALL SEPARATIONPROVISIONS OF TABLE R302.6 SHALL NOT APPLY TO GARAGE WALLS THAT ARE PERPENDICULAR TO THEADJACENT "DWELLING UNIT" WALL. PER R302.12D: IN COMBUSTIBLE CONSTRUCTION WHERE THERE ISUSABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR-CEILING ASSEMBLY,DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED1,000 SF. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS.WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW,DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR-CEILING ASSEMBLIES UNDER THE FOLLOWINGCIRCUMSTANCES: 1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. 2. FLOOR FRAMING ISCONSTRUCTED OF TRUSS-TYPE OPEN WEB OR PERFORATED MEMBERS.PROJECT INFORMATION:NOTES:1. SEE SURVEY FOR DETAILED DIMENSIONS ANDNOTES.2. 2023 FLORIDA BUILDING CODE :3. SEE SHEET S-1.0 FOR ADDITIONAL NOTES4. HEIGHTS REFERENCED = NGVD 1929;PROJECT DESCRIPTION: REMODEL/ADDITION TOEXISTING SINGLE FAMILY RESIDENCE.PROJECT ADDRESS: 381 SEMINOLE ROAD ATLANTIC BEACH, FL 32233LEGAL DESCRIPTION: 03114 SALTAIR SEC 02TAX ASSESSORS PARCEL NO.: 170433-0010ZONE: RS-2LOT SIZE:5,000 SFSETBACKS:STREET / FRONT20'SIDE15' TOTAL (MIN. 5')REAR 20'MAX. BLDG. HEIGHT: 35' TO RIDGECONSTRUCTION SITE MANAGEMENT PLAN:1. PARKING PLAN: PARKING TO BE ACCESSED FROM8TH STREET ONLY @ EXISTING CURB LOCATION.2. CONSTRUCTION TRAILERS, LOADING/UNLOADINGAREA, AND MATERIAL STORAGE TO BE CONTAINEDWITHIN PROPERTY LINE @ THE FRONT 20' X50' AREAOF BUILDING SITE, ACCESSED FROM THE CURRENTCURB LOCATION AT 8TH STREET.3. THE CHEMICAL TOILET ARE TO BE KEPT OUT OF THECITY RIGHT-OF-WAY AND NOT FURTHER THAN 15 FEETFROM THE STRUCTURE UNDER CONSTRUCTION.4. LOCATION OF DUMPSTER: DUMPSTER MUST BEFROM CITY-APPROVED WASTE COMPANY, INACCORDANCE WITH CHAPTER 16 OF THE CITY OFATLANTIC BEACH CODE OF ORDINANCES. DUMPSTERSARE TO HAVE A TARP COVERS OR RIGID COVERS ONWINDY DAYS. DUMPSTERS MUST BE REMOVED PRIORTO ISSUANCE OF CERTIFICATE OF OCCUPANCY ORCERTIFICATE OF COMPLETION.5. TRAFFIC CONTROL PLAN: CONTRACTOR TOPROVIDE SAFE AND CLEAN AREA AT THE 20'X50' AREAAT THE FRONT OF SITE ACCESSIBLE FROM 8THSTREET AT THE CURRENT CURB AND DRIVEENTRANCE THROUGHOUT CONSTRUCTION UNTIL NEWDRIVE ACCESS IS INSTALLED UPON COMPLETION.6. SITE CLEANLINESS: CONTRACTOR MUST HAVE THEENTIRE CONSTRUCTION SITE CLEANED BY FRIDAY OFEACH WEEK. THIS MEANS REMOVAL OF SCRAPLUMBER, CONCRETE REMNANTS, AND OTHER SUCHCONSTRUCTION DEBRIS INCLUDING CANS, METAL,PLASTIC AND PAPER.7. EROSION AND SEDIMENT CONTROL: CONTRACTORMUST MAINTAIN ALL ELEMENTS OF THE APPROVEDEROSION & SEDIMENT CONTROL PLAN (SILT FENCE,CATCH BASIN FILTERS,ETC.) UNTIL SOD OR OTHERSTABILIZATION HAS BEEN PLACED AND APPROVED BYPUBLIC WORKS.8. OTHER ACTIVITIES, WHERE SPECIAL CONDITIONSARE IDENTIFIED BY THE BUILDING OFFICIAL.NOTE: FAILURE TO COMPLY WITH THE CONSTRUCTIONSITE MANAGEMENT ORDINANCE MAY RESULT IN ASTOP WORK ORDER BEING ISSUED IN ACCORDANCEWITH THE CITY OF ATLANTIC BEACH CODE OFORDINANCES SEC. 6-17 (b)(3).LEGEND:EXISTING BUILDINGFOOTPRINTADDITION / BUILDINGFOOTPRINTCOVERED LANAIPOOLPOOL COPING &A/C PADSLOT COVERAGE:LOT AREA = 5,000 SFALLOWABLE LOT COVERAGE: 45%5,000 SF X .45 = 2,250 SFNO CHANGE TO EXISTING LOT COVERAGE:PER EXISTING SURVEY:DRIVE & WALK 416 SFEXISTING HOUSE1,367 SFCONC. PADS 91 SFPOOL DECK 652 SFPOOL PAD 16 SFTOTAL 2,492 SFLOT5,000 SFIMPERVIOUS LOT COVERAGE = 49.8% (EXISTING)EXISTINGCOVEREDLANAIEXISTING SCREENEDPOOL ENCLOSUREEXISTINGPOOLEXISTINGCOVEREDLANAIEXISTING BUILDINGFOOTPRINT W/ NEW2ND FLOOR ADDITIONABOVE - NO ADDITIONALGROUND FLOORIMPERVIOUS SURFACECOVER SHEET /SITE PLANA1.0BURGOS RESIDENCE ATLANTIC BEACH, FL 32233 381 SEMINOLE ROAD 345 South Roscoe Blvd. Ponte Vedra Beach, FL 32082 v.727.483.2422PROGRESS SETcopyrightDRAWING TITLERAE 02.22.24BURGOScDATECLIENTREVISIONSSHEET NO.JOB NO.2318NO.DESCRIPTION DATEAR97282RSCOTTRAEdesign 16070 GARAGE DOORFIRST FLOOR PLAN11/4" = 1'-0" UPAS-BUILT1A4.1EXISTINGCOVERED LANAIEXISTING2-CAR GARAGEEXISTINGFAMILY ROOMEXISTINGFLEX AREAEXISTINGKITCHENEXISTINGLIVING ROOMNOTE: NO CHANGES @EXISTING FIRST FLOOR LEVELEXIST. WIN.EXIST. WIN.EXIST. WIN.EXIST. WIN.SECOND FLOOR PLAN21/4" = 1'-0" AS-BUILTDNEXISTINGFAMILY ROOMEXISTINGCOVERED LANAIROOFEXISTINGBEDROOMEXISTINGBEDROOMEXISTINGPRIMARYBEDROOMEXISTINGW.I.C.EXISTINGPRIMARYBATHROOMEXISTINGBATHROOMEXISTINGHALL(VUALTED CEILING)EXISTINGSTAIREXISTING2-CAR GARAGEROOFSECOND FLOOR PLAN31/4" = 1'-0" DNTVEXISTINGBEDROOMTVEXISTINGBEDROOMBALCONY1'-1012"EXISTING HOUSE BENCH9'-10"10'-2"11'-412" 11'-41 2"1A4.1LEGEND:EXISTING WALL35'-212"NEW WALL6'-614"7'-2"20'-212"6'-614"15'-0"40'-6" 8'-113 4"19'-103 4"11'-71 2"37'-4"7'-3"11'-0"11'-4"5'-712"42'-412" 1'-1012"5'-6"35'-0" 13'-10"7'-2"14'-0"2'-112"2846 SHHDR @ 7'-6" AFF2846 SHHDR @ 7'-6" AFFEXISTINGCOVERED LANAIROOF30803080(EXIST)(E X I S T )RISE/RUNVIF(8' CLG)(8' CLG)1'-1012"2'-0" 3'-1012" 512" 15'-012" 512" EXIST. WIN.EXIST. WIN.EXIST. WIN.EXIST. WIN.EXIST. WIN.EXIST. WIN.SLOPE 18" PER FT.+3' RAILEXISTINGBATHROOMDRESSING PRIMARYBEDROOM(9' CLG)TVPRIMARYBATHROOM(9' CLG)LAUNDRYLINENW.I.C.(9' CLG)DWSHOWER2868DESKOFFICE /FUTUREBEDROOM(8' CLG)EXISTINGROOFLINE OF EXISTINGROOFLINE OF EXISTINGROOF6020 FG HDR @ 7'-6" AFF ROOF SLOPE EXIST. TYP. 31 2" 6'-1112" 31 2" 3'-0" 13'-012" 3'-0" 31 2" 4'-3"3'-812" 31 2" 13'-0" 51 2"512"5'-714"7'-912"13'-434"4'-0"5'-812"3'-112"6'-7"4'-0"13'-812"7'-6" 312" 3'-2" 312" 2'-312"10'-812"5'-7"312"3'-612"312"4'-0"6'-1112"3'-612"3'-10"5'-7"5'-6"3'-4"312"2'-0"312"5'-714"512"2X6 WALL ATTENTION:ALL WINDOW HEAD HEIGHTS ARE MEASURED FROM MAIN FINISHFLOORS AS INDICATED AT ELEVATIONS, NOT FROM GARAGEFLOOR OR GARAGE CURB, TYP.ATTENTION:SHOWER HEADS @ 7' ABOVE SHOWER FLOOR, TYP.NOTES:1. ALL EXTERIOR WALLS ARE 2X6 EXCEPT AS NOTED.2. ALL INTERIOR WALLS ARE 2X4 EXCEPT AS NOTED.3. ALL WALL THICKNESSES ARE ACTUAL 2X4 = 3 12", 2X6 = 5 12",2xTHE SIZE AND QUANTITY OF ALL EXTERIOR STEPS ARE TO BEFIELD DETERMINED BY OTHERS.5. ALL PLATE AND CEILING HEIGHTS ARE TAKEN FROM (TOP OF)HOUSE SLAB/BLOCK.6. VERIFY THE KITCHEN AND VANITY LAYOUTS WITH THE DETAILSDONE BY OTHERS.7. ALL INTERIOR AND EXTERIOR FLOOR & STEPS SHALL HAVE ANON-SLIP FINISH TO MEET ASTM C1028 STATIC COEFFICIENT OFFRICTION MIN. OF 0.6.8. ALL WOOD IN CONTACT WITH MASONRY, CONCRETE OR EARTHSHALL BE PRESSURE TREATED APPROPRIATELY FOR THECONDITION.9. T = GLASS TO BE TEMPERED10. E = EMERGENCY ESCAPE AND RESCUE OPENINGS11. C = 20 MIN. FIRE RATED DOORAREA TABULATION:BLDG SF TABULATION:1ST FLOOR LIVING EXISTING 949 SF (A/C SF)2ND FLOOR EXISTING 749 SF (A/C SF)2ND FLOOR ADDITION 314 SF (A/C SF)TOTAL 2,012 SF (A/C SF)2-CAR GARAGE 400 SFFRONT PORCH 16 SFTOTAL WITH ADDITION2,428 SFNOTE: EXISTING TOTAL SF = 2,114 SF PER DUVAL COUNTYPROPERTY APPRAISER1ST & 2NDFLOOR PLANA2.1BURGOS RESIDENCE ATLANTIC BEACH, FL 32233 381 SEMINOLE ROAD 345 South Roscoe Blvd. Ponte Vedra Beach, FL 32082 v.727.483.2422PROGRESS SETcopyrightDRAWING TITLERAE 02.22.24BURGOScDATECLIENTREVISIONSSHEET NO.JOB NO.2318NO.DESCRIPTION DATEAR97282RSCOTTRAEdesign ROOF PLAN11/4" = 1'-0" ROOF ATTIC/VENTILATION AREA CALCULATIONS:EXCERPT OF THE 2020 FLORIDA BUILDING CODE, RESIDENTIAL R806:R806.1 VENTILATION REQUIRED:ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS AREAPPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSSVENTILATION FOR EACH SEPARATED SPACE BY VENTILATING OPENINGS AGAINSTTHE ENTRANCE OF RAIN OR SNOW.VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF 1/16 INCH (1.6 MM)MINIMUM TO 1/4 INCH (6.4 MM) MAXIMUM OPENINGS. VENTILATION OPENINGS HAVINGA LEAST DIMENSION LARGER THAN 1/4 INCH (6.4 MM) SHALL BE PROVIDED WITHCORROSION-RESISTANT WIRE CLOTH SCREENING. HARDWARE CLOTH, OR SIMILARMATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16 INCH (1.6 MM)MINIMUM AND 1/4 INCH (6.4 MM) MAXIMUM. OPENINGS IN ROOF FRAMING MEMBERSSHALL CONFORM TO THE REQUIREMENTS OF SECTION R802.7 REQUIREDVENTILATION OPENINGS SHALL OPEN DIRECTLY TO OUTSIDE AIR.R806.2 MINIMUM VENT AREA:THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THEVENTED SPACE.EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/300 OF THEVENTED SPACE PROVIDED ONE OR MORE OF THE FOLLOWING CONDITIONS ARE MET:1. IN CLIMATE ZONES 6, 7, & 8, A CLASS I OR II VAPOR RETARDER IS INSTALLED ONTHE WARM-IN-WINTER SIDE OF THE CEILING.2. AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIREDVENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTIONOF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOMORE THAN 3 FT. (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE,MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATIONPROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOFFRAMING MEMBERS CONFLICT WIT THE INSTALLATION OF UPPER VENTILATORS,INSTALLATION MORE THAN 3 FT. (914 MM) BELOW THE RIDGE OR HIGHEST POINT OFTHE SPACE SHALL BE PERMITTED.NOTE: NO VENTING PROVIDED IN LIVING AREAS DUE TO SPRAYFOAM INSULATION.NOTE:1. ROOF OVERHANGS 16" UNLESS NOTED OTHERWISE.2. ROOF PITCH = MATCH EXISTING UNLESS NOTED OTHERWISE.3. ROOF FRAMING TO BE WOOD TRUSSES SET @ ( ) " O.C..4. ROOF FRAMING LUMBER TO BE #2 OR BETTER5. INDICATES DIRECTION OF ROOF SLOPE.EXISTINGCOVERED LANAIROOFROOF SLOPE EXIST. TYP. 2'-0" 1'-6" 2'-0"1'-6"1'-6"ACCENTROOF OVER2ND FLOORBALCONYROOFSLOPE7:12ROOFSLOPE7:12NEW ROOFAREA (HATCHED)NEW ROOFAREA (HATCHED)NEW ROOFAREA (HATCHED)NEW ROOFAREA (HATCHED)ROOF SLOPE EXIST. TYP. ROOF SLOPE EXIST. TYP. ROOF SLOPE EXIST. TYP. ROOF SLOPE EXIST. TYP. ROOF SLOPE EXIST. TYP. ROOF SLOPE EXIST. TYP.NEW ROOFAREA (HATCHED)OVER-FRAME HEREAS REQUIREDEXISTINGRIDGEEXISTINGRIDGEEXISTINGRIDGEKICK-OUT FLASHINGEXTERIOR STUD >. HGT. PER SPEC.DRIP EDGE DETAIL5N.T.S.SHINGLEROOFINGROOF SHEATHINGPER SPECIFCATIONS2-LAYER SYNTHETICFELT DRY-INPAINTED METALEAVE DRIP; EXTENDBACK MIN. 2"1 X 2 P.T. FURRINGFASCIAROOF TO WALL4N.T.S.(ROOF PARALLEL TO WALL)KICK-OUT FLASHING 7N.T.S.WALL TO ROOF6N.T.S.SIDING PERELEVATIONSSIDING PER ELEVATIONSFINISH OVERLAPPINGTOP OF HEAD FLASHING5X5 HEAD FLASHING WITH TOP ZIP TAPEDTO ZIP SHEATHINGCOMPOSITE SHINGLE ROOFING2-LAYER SYNTHETIC FELTDRY-INEXISTING WOOD FRAMESYSTEMZIP BOARD WALLSHEATHINGSIDING PERELEVATIONS5X5 METAL HEADFLASHING2-LAYER SYNTHETICFELT DRY-IN2"SEEELEVKICK-OUTSHINGLE ROOFINGPER SPEC.FASCIAHOLD BACK FASCIAAND DRIP EDGE 2"FROM FACE OF WALLOUTSIDE FACE OFEXTERIOR WALLEXTERIOR FINISHPER ELEVATIONSFASCIAMETAL DRIP EDGEOUTSIDE FACE OFEXTERIOR WALLEXTERIOR WALLSHEATHING(WRB) WEATHERRESISTANT BARRIER5X5 FLASHING W/KICK-OUT TO SHEDWATER AWAY FROMHOUSE,TYP.(WRB) OVERLAPS THE5X5 FLASHING ROOFSHEATHINGVALLEY 2N.T.S.METAL VALLEY FLASHING ROOF SHEATHING W/ PLYCLIPSCOMPOSITE SHINGLE ROOFING 2-LAYERS OF SYNTHETIC FELTROOF OPENING AND OFF-RIDGE VENT3N.T.S.NOTES:1 - INSTALL IN STRICT ACCORDANCE WITHMANUFACTURER'S WRITTEN INSTRUCTIONS2 - APPLY ROOFING CEMENT OR SELF-ADHERINGFLASHING OVER FLANGE AT HEAD ONLYCOMPOSITE SHINGLE ROOFINGSEAL VENT FLANGE AT HEADGALVANIZED METAL OFF-RIDGE VENT,SET IN PLASTIC ROOFCEMENT OR SEALANTOR OFF-RIDGE VENTFLANGE OVER SHINGLE ROOFINGAT BASESHEATHING OVER ROOFMEMBERS PER ENG'S DETAILSROOF VENT / PIPE OR INSTALL ROOF VENT/PIPEOVERLAP SHINGLEFLASHINGFLASHINGFLASHINGROOF PLANA2.2BURGOS RESIDENCE ATLANTIC BEACH, FL 32233 381 SEMINOLE ROAD 345 South Roscoe Blvd. Ponte Vedra Beach, FL 32082 v.727.483.2422PROGRESS SETcopyrightDRAWING TITLERAE 02.22.24BURGOScDATECLIENTREVISIONSSHEET NO.JOB NO.2318NO.DESCRIPTION DATEAR97282RSCOTTRAEdesign 6"8'-0"9'-0" PLATE HT. @ 2ND FL ADDITION F.F. @ FIRST FLOOR1'-4"F.F. @ SECOND FLOOR11/4" = 1'-0" FRONT ELEVATION11/4" = 1'-0" COMP. SHINGLEROOF127ACCENTROOFCEMENT BOARD& BATTEN SIDINGCEMENT BOARDLAP SIDINGCEMENT BOARDSHAKE SIDING(EXISTING)+3' RAILNEW BALCONYOFF PRIMARYBEDROOM(NEW)(NEW)(NEW)(EXISTING)(EXISTING)(EXISTING)(EXISTING)(EXISTING)EXISTING ROOF26'-11 4"T.O. ROOF26'-114" 6"8'-0"9'-0"F.F. @ FIRST FLOOR1'-4"T.O. ROOFF.F. @ SECOND FLOOR1/4" = 1'-0" RIGHT SIDE ELEVATION21/4" = 1'-0" COMP. SHINGLEROOFEXISTINGCOVERED LANAI12VIFTYP.CEMENT BOARDLAP SIDINGCEMENT BOARDSHAKE SIDING(EXISTING)CEMENT BOARD& BATTEN SIDING+3' RAIL26262626262828226SLOPE 2% MIN.TYPICAL ROOF DECK FRAMINGCOMP. ROOF O/ROOF SHEATHING PER STRUCT. O/PRE-MANUFACTURED ROOF TRUSSES O/ INSTALL PER MFG. SPEC. O/12" G.W.B.TYPICAL FLOOR FRAMINGFLOOR FINISH T.B.D. O/UNDERLAYMENT T.B.D. O/FLOOR SHEATHING PER STRUCT.O/FLOOR JOISTS PER STRUCT. O/12" G.W.B.22 GA. GALV. HEAD FLASHING (PAINT);;LAP UNDER BLDG PAPER; SLOPE AWAYFROM WALL @ 0.25:12 MIN.5/4X4 CEMENT BD WINDOW TRIMWHERE LAP SIDING OCCURS; SLOPEAWAY FROM WALL @ 0.25:12 MIN.WINDOW HEAD W/ NAILING FLANGE;INSTALL PER MFG. SPEC.; LAP INTOBLDG. PAPER; TYP.WINDOW SIL W/ NAILING FLANGE;INSTALL PER MFG. SPEC.; LAP INTOBLDG. PAPER; TYP.RIM JOIST OR BEAM PER STRUCT.R-21 BATT INSULATION @ EXT. WALLW/IN FLOOR CAVITYR-21 INSULATED WINDOW HEADER PERSTRUCT.TYPICAL EXTERIOR WALLEXTERIOR SIDING PER ELEVATION O/WATERPROOF BLDG. PAPER O/SHEATHING PER STRUCT. O/2X6 STUDS @ 16" O.C. W/ R-21 BATT INSULATION& VAPOR BARRIER (WARM SIDE) O/12" G.W.B.TYPICAL FIRST FLOOR S.O.G. ASSEMBLYFLOOR FINISH T.B.D. O/UNDERLAYMENT T.B.D. O/4" CONC. S.O.G. PER STRUCT. O/2" R-10 RIGID INSULATION O/6 MIL POLYETHELENE VAPOR BARRIER O/6" FREE DRAINING GRAVEL O/FIRM NATIVE SOILS22 GA. GALV. DRIP EDGE; LAP UNDERBLDG PAPER; TYP. @ HORIZONTALLEDGES AND CHANGES IN SIDING4" PERFORATED DRAIN TILE W/ FABRICFILTER; TYP. @ EXTERIOR FOOTINGS;CONNECT TO STORM DRAIN SYSTEM6" MIN. FREE DRAINING GRAVELAROUND DRAIN TILE; TYP.CONC. FOOTING AND FOUNDATIONWALL PER STRUCT.WALL SECTION, TYP.33/4" = 1'-0" 25/4X4 CEMENT BD WINDOW TRIMWHERE LAP SIDING OCCURS; SLOPEAWAY FROM WALL @ 0.25:12 MIN.PER STRUCT.18" MIN.2 X 12 STRINGER; SIDECARRIAGES SUPPORTED CONT. ON ADJ. WALLFRAMING23'-0"TYP.WOOD TREAD7 3/4"MAX.2HEADSTAIR SECTION51/2" = 1'-0" TOP / LANDINGINSTALL CONTINUOUS 36" CS14 @ EACHSTRINGER LOCATION PRIOR TO STAIR INSTALLATION TO ALLOW FOR PROPER NAILING, TYP.6"4"SPHERE MAX. SPHERE MAX. 10"1"NOSINGSTANDARD 1" TREADS10"2222 X 12 STRINGER; SIDECARRIAGES SUPPORTED CONT. ON ADJ. WALLFRAMING22FOOT7 3/4"MAX.STAIR SECTION41/2" = 1'-0" BOTTOM3'-0"(BY OTHERS) - 2" X 3/8" CONT. PWDR COATED STL. GUARDRAIL, TYP.STL. STL. CABLE, TYP.6"SPHERE MAX. 4"SPHERE MAX. 1"NOSING1"STANDARD 1" TREADS2222EXTERIORELEVATIONSA3.1BURGOS RESIDENCE ATLANTIC BEACH, FL 32233 381 SEMINOLE ROAD 345 South Roscoe Blvd. Ponte Vedra Beach, FL 32082 v.727.483.2422PROGRESS SETcopyrightDRAWING TITLERAE 02.22.24BURGOScDATECLIENTREVISIONSSHEET NO.JOB NO.2318NO.DESCRIPTION DATEAR97282RSCOTTRAEdesign 11/4" = 1'-0" REAR ELEVATION11/4" = 1'-0" COMP. SHINGLEROOFEXISTINGCOVERED LANAI127CEMENT BOARDLAP SIDING(EXISTING)(EXISTING)(EXISTING)(EXISTING)(EXISTING)(EXISTING)(EXISTING) 6"8'-0"8'-0"F.F. @ FIRST FLOOR1'-4"F.F. @ SECOND FLOOR26'-11 4"T.O. ROOF1/4" = 1'-0" REAR ELEVATION21/4" = 1'-0" COMP. SHINGLEROOFEXISTINGCOVERED LANAICEMENT BOARDLAP SIDINGCEMENT BOARDLAP SIDING+3' RAIL(EXISTING)(EXISTING)(NEW)6"8'-0"8'-0"F.F. @ FIRST FLOOR1'-4"F.F. @ SECOND FLOOR26'-11 4"T.O. ROOF12VIFTYP.WINDOW INSTALLATION 31/2" = 1'-0" NOTE:WEATHER RESISTIVE BARRIER (WSB)APPLIED PRIOR TO THE WINDOWINSTALLATION. FLASHING APPLIED OVER THEFACE OF THE MOUNTING FLANGE.STEPS:1.IN THE WATER SHEDDING FASHION,STARTING AT THE BASE OF THE WALL& WORKING TOWARDS THE TOP,INSTALL THE WRB TO THE FACE OFTHE SHEATHING2.APPLY SILL FLASHING.3.APPLY BEAD OF SEALANT AT BACK OFWINDOW FLANGE & SET WINDOWUSING PAN HEAD SCREWS TOFACILITATE INSPECTION.4.APPLY BEAD OF SEALANT AT SIDEJAMBS, EXTEND 8 12"5.APPLY JAMB FLASHING.6.APPLY BEAD OF SEALANT AT HEAD.7.APPLY HEAD FLASHING.8.REMOVE PREVIOUSLY APPLIED TAPE,ALLOWING WRB TO LAY FLAT OVERHEAD FLASHING. APPLY NEWSHEATHING TAPE OVER DIAGONALCUT - SEE DIAGRAM.26265.JAMB FLASHING:APPLY CONT. SEAL TO THEMOUNTING FLANGES AT THETOP (HEAD) AND SIDES (JAMB)OF WINDOW. EXTEND SEALANTAT JAMBS 8 12" ABOVE THE R.O.AT HEAD. EMBED JAMBFLASHING INTO SEALANT ANDFASTEN IN PLACE. (FLASHINGGOES OVER SEALANT.)SEAL THE WINDOW FRAME TO OPENING.APPLY A 38" NOM. DIA. TO THE BACKSIDE(INTERIOR) OF THE WINDOW FLANGE, IN LINEWITH ANY PRE-PUNCHED HOLES OR SLOTS.SEALANT BEADBEHIND MOUNTINGFLANGESECTION ATHROUGH WINDOW JAMBSEALANT BEADBETWEEN FLASHINGAND MOUNTING FLANGEFLASHINGSECURE WRB@ HEAD8.7.5.3.2.1.5.FLASHING AT HEADEXTENDS 1" BEYONDJAMB FLASHING.7.HEAD FLASHING:EMBED BOTTOM OF THE HEADFLASHING AGAINST THEPREVIOUSLY APPLIED SEALANT(FLASHING GOES OVERSEALANT). EXTEND HEADFLASHING BEYOND EACH JAMBFLASHING. FASTEN IN PLACE.5.JAMB FLASHING:EXTEND JAMB FLASHING TOOVERLAP SILL FLASHING.EXTEND JAMB FLASHING 8 12"ABOVE ROUGH OPENING ATHEAD. TUCK TOP OF JAMBFLASHING UNDER THE FLAPOF WRB AT THE HEAD. SEEDIAGRAM.SILL FLASHING.SHIM AND ADJUST WINDOW TO ACHIEVESQUARE, PLUMB AND LEVEL CONDITION. USECORROSION RESISTANT FASTENERS. FASTENWINDOWS PER WINDOW MANUFACTURERSPECIFICATIONS.1.WEATHER RESISTANT BARRIER (WRB):AT A 45 DEGREE ANGLE,CAREFULLY CUT THE BARRIERON A DIAGONAL. GENTLY RAISETHE TOP EDGE OF THEBARRIER UP AND TAPE THETOP CORNERS AND CENTERTO THE EXTERIOR WRBSURFACE ABOVE.8.1.CUTLINE8 12"SEALANT8.AASEALANTINTERIOR VIEWTOP LEFT CORNEROF WINDOWNOTE: ALL FLASHING WILL BE SELF ADHEARING AND ROLLED SMOOTH AND FLAT WITH A J-ROLLER.WRBWRB1WRBWRBWRBWRBWRB45°CUTEXTERIOR DOOR FLASHING4N.T.S.23456WRBWRBWRB9"9"8"WRAP WRBINTO OPNG.MODIFIED "J"CUT IN WRBREMOVE BOTTOMWRB FLAPTEMPORARILY TAPE UP TOP FLAPINSTALL VULKUM @ THRESHHOLDPER MFG. INSTRUCTIONS; INSTALLDOOR, SHIM DOOR TO LEVEL; PLUMBAND SQUARE DOOR TO OPENINGAPPLY JAMB FLASHING TO BOTH SIDES OF DOORTO DOOR FRAME TO WRB EXTENDING 8" ABOVEDOOR ROUGH OPENINGAPPLY HEAD FLASHING, EXTENDING 10" BEYONDDOOR ROUGH OPENINGUNFOLD TOP FLAP AND COVER DIAGONAL CUTIN WRB WITH SHEATHING TAPEFASTEN ZIP SYSTEM ®SHEATHING AS REQUIRED BYENGINEER-OF-RECORDAND/OR LOCAL BUILDING CODEZIP WALL CEMENT BOARD5N.T.S.WALL ASSEMBLY:CEMENTITIOUS VENEER W/CNTRL JOINTS PER CODE;SIDING INSTALLED INACCORDANCE WITHMANUFACTURER'SINSTALLATIONRECOMMENDATIONS;ZIP SYSTEM ® SHEATHINGO/ WOOD STUDS1/8" GAP RECOMMENDED@ PANEL EDGES, TYP.ZIP SYSTEM ® TAPE (INSTALLEDOVER ALL JOINTS IN ZIP SYSTEM ®SHEATHING)OVERLAP TAPE A MINIMUM OF1" @ ALL T-JOINTS1/8" GAP RECOMMENDED @PANEL EDGES,TYP.LAP SIDING DTL.EXTERIORELEVATIONSA3.2BURGOS RESIDENCE ATLANTIC BEACH, FL 32233 381 SEMINOLE ROAD 345 South Roscoe Blvd. Ponte Vedra Beach, FL 32082 v.727.483.2422PROGRESS SETcopyrightDRAWING TITLERAE 02.22.24BURGOScDATECLIENTREVISIONSSHEET NO.JOB NO.2318NO.DESCRIPTION DATEAR97282RSCOTTRAEdesign ELECTRICAL NOTES:1. ALL OUTLETS IN BEDROOM TO BE "A.F.I."2. ALL EXTERIOR OUTLETS TO BE "G.F.I."3. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH ARTICLE80 OF NFPA 70A4. NOTE: 100% HIGH EFFICACY LIGHTING5. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMP BRANCHCIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNITS,FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS,LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS,CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BEPROTECTED BY A LISTED AFCI, COMBINATION TYPE, INSTALLEDTO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER 210.12(B)ATTENTION:CENTER OF BOXES OF ALL VANITY LIGHTS TO BE AT 7'-8" AFF,EXCEPT 8'-6" IN OWNER'S BATHSURFACE MOUNTED CEILING FIXTURERECESSED WATER PROOF CEILING FIXTURESCONCEUNDER CABINET LED STRIP LIGHTINGRECESSED CEILING FIXTURE110 V. DUPLEX OUTLET110 V. WATER PROOF DUPLEX OUTLET W/ GFI220 V. OUTLETEXHAUST FAN110 V. SMOKE / CO2 DETECTORWATER HEATER THERMOSTATDATA (18" AFF)LIGHT SWITCH3-WAY LIGHT SWITCHLIGHT SWITCH WITH DIMMERELECTRICAL LEGENDSYMBOLDISCRIPTIONWPWP/GFCIT WHDS3SDSNOTES:1. PER FBC-R E3902.10; THE BRANCH CIRCUIT FOR THE DISHWASHERSHALL HAVE A GROUND-FAULT CIRCUIT INTERRUPTER, TYP.2. PER FBC-R E3902.16; BRANCH CIRCUITS IN THE KITCHEN, LIVINGROOM, DINING ROOM, HALLWAYS, BEDROOMS, LAUNDRY AREA,ENTRY FOYER, STAIRWAY, CLOSETS AND OTHER SIMILAR AREASSHALL HAVE A ARC-FAULT CIRCUIT INTERRUPTER PROTECTION, TYP.3. PER FBC-R E 4002.14; RECEPTACLES TO BE TAMPER-RESISTANT, TYP.EXTERIOR FLOOD FIXTURE - MOTION SENSOREXHAUST FAN W/ LIGHT110 V. WATER PROOF DUPLEX OUTLET W/ GFION GROUND FAULT CIRCUITGFCI220GFCISD/CO2CABLE TV OUTLETTVWAPWIRELESS ACCESS POINTSURF. MOUNTED HANGNING PENDANT FIXTUREEXTERIOR FLOOD LIGHT110 V. QUAD OUTLET FLOOR OUTLETGARAGE DOOR PUSH BUTTONTHERMOSTATTSECOND FLOOR RCP/ELEC11/4" = 1'-0" DNTVEXISTINGBEDROOMTVEXISTINGBEDROOMBALCONYBENCHEXISTINGCOVERED LANAIROOF(8' CLG)(8' CLG)EXISTINGBATHROOMDRESSING PRIMARYBEDROOM(9' CLG)PRIMARYBATHROOMLAUNDRYLINENW.I.C.(9' CLG)DWSHOWERDESKOFFICE /FUTUREBEDROOM(8' CLG)EXISTINGROOFLINE OF EXISTINGROOFLINE OF EXISTINGROOFSS SS SEXISTINGHALLSD/CO2S S TVD TVDSHOWERWPSSSGFCIGFCIGFCISS GFCI220GFCIGFCIS SD/CO2SD/CO21ST & 2ND RCP/ELEC.A4.1BURGOS RESIDENCE ATLANTIC BEACH, FL 32233 381 SEMINOLE ROAD 345 South Roscoe Blvd. Ponte Vedra Beach, FL 32082 v.727.483.2422PROGRESS SETcopyrightDRAWING TITLERAE 02.22.24BURGOScDATECLIENTREVISIONSSHEET NO.JOB NO.2318NO.DESCRIPTION DATEAR97282RSCOTTRAEdesign