381 Seminole Road RESA24-0006 Revision 04.05.2024 2024-04-02 Archs - rev final - BurgosSEMINOLE DRIVE PROPERTY LINE100.00'PROPERTY LINE 50.00'PROPERTY LINE100.00'PROPERTY LINE 50.00' SITE PLAN1SCALE: 1/8" = 1'-0"N20'-0"FRONT20'-0"REAR7'-6"7'-6" NOTES: (FBC 2023-R) 1. DRAFT STOPPING TO BE INSTALLED AS REQUIRED PER FBC R-3022.12: "IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SF." 2. DWELLING/GARAGE FIRE SEPARATION TO BE PER FBC R-302.6: "NOT LESS THAN 1 2" THICK GYPSUM BOARD OR EQUIVALENT APPLIED TO GARAGE SIDE." 3. OPENING PROTECTION FOR DOOR BETWEEN GARAGE AND RESIDENCE TO BE PER FBC R-302.5.1: "OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3 8" IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3 8" THICK, OR 20-MINUTE FIRE-RATED DOORS." 4. ATTIC ACCESS TO BE SIZED PER FBC R-807.1: "THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22"X30" AND SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION." 5. ALL BATHROOM SHOWER ENCLOSURES TO HAVE SAFETY GLAZING IN COMPLIANCE WITH FBC R-308.4.5. 6. WHERE GLAZING ADJACENT TO STAIRS IS LESS THAN 36" ABOVE THE WALKING SURFACE, SAFETY GLAZING WILL BE PROVIDED PER FBC R- 308.4.6. 7. DOOR BETWEEN RESIDENCE AND GARAGE WILL BE SELF-CLOSING PER FBC R-302.5.1. NOTES: (FBC 2023-R) 4. FBC R-703.7.3 - WATER RESISTIVE BARRIERS - WATER RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED SHEATHING, SHALL INCLUDE A WATER RESISTIVE VAPOR PERMEABLE BARRIER WITH A PERFORMANCE TEST AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER RESISTIVE BARRIER IS DIRECTED BETWEEN THE LAYERS. EXCEPTION: WHERE THE WATER RESISTIVE BARRIER THAT IS APPLIED OVER WOOD BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER THAN THAT OF A 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO BY AN INTERVENING, SUBSTANTIALLY NONWATER-ABSORBING LAYER OR DESIGNED DRAINAGE SPACE. 5. FBC R-M1305.1 - APPLIANCE ACCESS FOR INSPECTION SERVICE, REPAIR AND REPLACEMENT - "APPLIANCES" SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER "APPLIANCES" OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE "APPLIANCE" BEING INSPECTED, SERVICED, REPAIRED OR REPLACED. A LEVEL WORKING SPACE NOT LESS THAN 30" DEEP AND 30" WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE THE APPLIANCE. 1. FBC R-302.5.1 - OPENING PROTECTION: OPENINGS FROM A PRIVATE GARAGE DIRECTLY TO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3 8" INCHES IN THICKNESS, SOLID OR HONEYCOMB-CORE STEEL DOORS NOT LESS THAN 1 3 8" THICK, OR 20-MINUTE FIRE-RATED DOORS. 2. FBC R-302.5.2 - DUCT PENETRATION: DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE "DWELLING" FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER "APPROVED" MATERIAL AND SHALL NOT HAVE OPENINGS INTO THE GARAGE. 3. FBC R-302.6 - DWELLING-GARAGE FIRE SEPARATION: THE GARAGE SHALL BE SEPARATED AS REQUIRED BY TABLE R302.6. OPENINGS IN GARAGE WALLS SHALL COMPLY WITH SECTION R302.5. ATTACHMENT OF GYPSUM BOARD SHALL COMPLY WITH TABLE R702.3.5. THE WALL SEPARATION PROVISIONS OF TABLE R302.6 SHALL NOT APPLY TO GARAGE WALLS THAT ARE PERPENDICULAR TO THE ADJACENT "DWELLING UNIT" WALL. PER R302.12D: IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR-CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SF. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR-CEILING ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES: 1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. 2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN WEB OR PERFORATED MEMBERS. PROJECT INFORMATION: NOTES: 1. SEE SURVEY FOR DETAILED DIMENSIONS AND NOTES. 2. 2023 FLORIDA BUILDING CODE : 3. SEE SHEET S-1.0 FOR ADDITIONAL NOTES 4. HEIGHTS REFERENCED = NGVD 1929; PROJECT DESCRIPTION: REMODEL/ADDITION TO EXISTING SINGLE FAMILY RESIDENCE. PROJECT ADDRESS: 381 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 LEGAL DESCRIPTION: 03114 SALTAIR SEC 02 TAX ASSESSORS PARCEL NO.: 170433-0010 ZONE: RS-2 LOT SIZE:5,000 SF SETBACKS: STREET / FRONT 20' SIDE 15' TOTAL (MIN. 5') REAR 20' MAX. BLDG. HEIGHT: 35' TO RIDGE CONSTRUCTION SITE MANAGEMENT PLAN: 1. PARKING PLAN: PARKING TO BE ACCESSED FROM 8TH STREET ONLY @ EXISTING CURB LOCATION. 2. CONSTRUCTION TRAILERS, LOADING/UNLOADING AREA, AND MATERIAL STORAGE TO BE CONTAINED WITHIN PROPERTY LINE @ THE FRONT 20' X50' AREA OF BUILDING SITE, ACCESSED FROM THE CURRENT CURB LOCATION AT 8TH STREET. 3. THE CHEMICAL TOILET ARE TO BE KEPT OUT OF THE CITY RIGHT-OF-WAY AND NOT FURTHER THAN 15 FEET FROM THE STRUCTURE UNDER CONSTRUCTION. 4. LOCATION OF DUMPSTER: DUMPSTER MUST BE FROM CITY-APPROVED WASTE COMPANY, IN ACCORDANCE WITH CHAPTER 16 OF THE CITY OF ATLANTIC BEACH CODE OF ORDINANCES. DUMPSTERS ARE TO HAVE A TARP COVERS OR RIGID COVERS ON WINDY DAYS. DUMPSTERS MUST BE REMOVED PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY OR CERTIFICATE OF COMPLETION. 5. TRAFFIC CONTROL PLAN: CONTRACTOR TO PROVIDE SAFE AND CLEAN AREA AT THE 20'X50' AREA AT THE FRONT OF SITE ACCESSIBLE FROM 8TH STREET AT THE CURRENT CURB AND DRIVE ENTRANCE THROUGHOUT CONSTRUCTION UNTIL NEW DRIVE ACCESS IS INSTALLED UPON COMPLETION. 6. SITE CLEANLINESS: CONTRACTOR MUST HAVE THE ENTIRE CONSTRUCTION SITE CLEANED BY FRIDAY OF EACH WEEK. THIS MEANS REMOVAL OF SCRAP LUMBER, CONCRETE REMNANTS, AND OTHER SUCH CONSTRUCTION DEBRIS INCLUDING CANS, METAL, PLASTIC AND PAPER. 7. EROSION AND SEDIMENT CONTROL: CONTRACTOR MUST MAINTAIN ALL ELEMENTS OF THE APPROVED EROSION & SEDIMENT CONTROL PLAN (SILT FENCE, CATCH BASIN FILTERS,ETC.) UNTIL SOD OR OTHER STABILIZATION HAS BEEN PLACED AND APPROVED BY PUBLIC WORKS. 8. OTHER ACTIVITIES, WHERE SPECIAL CONDITIONS ARE IDENTIFIED BY THE BUILDING OFFICIAL. NOTE: FAILURE TO COMPLY WITH THE CONSTRUCTION SITE MANAGEMENT ORDINANCE MAY RESULT IN A STOP WORK ORDER BEING ISSUED IN ACCORDANCE WITH THE CITY OF ATLANTIC BEACH CODE OF ORDINANCES SEC. 6-17 (b)(3). LEGEND: EXISTING BUILDING FOOTPRINT ADDITION / BUILDING FOOTPRINT COVERED LANAI POOL POOL COPING & A/C PADS LOT COVERAGE: LOT AREA = 5,000 SF ALLOWABLE LOT COVERAGE: 45% 5,000 SF X .45 = 2,250 SF NO CHANGE TO EXISTING LOT COVERAGE: PER EXISTING SURVEY: DRIVE & WALK 416 SF EXISTING HOUSE 1,367 SF CONC. PADS 91 SF POOL DECK 652 SF POOL PAD 16 SF TOTAL 2,492 SF LOT 5,000 SF IMPERVIOUS LOT COVERAGE = 49.8% (EXISTING) EXISTING COVERED LANAI EXISTING SCREENED POOL ENCLOSURE EXISTING POOL EXISTING COVERED LANAI EXISTING BUILDING FOOTPRINT W/ NEW 2ND FLOOR ADDITION ABOVE - NO ADDITIONAL GROUND FLOOR IMPERVIOUS SURFACE PER SECTION 24-172(C)(1), SECOND AND THIRD STORY EXTERIOR WALLS WHICH EXCEED 35' IN LENGTH, SHALL PROVIDE HORIZONTAL OFFSETS 2' (DRIP EDGE) @ SIDE YARD SETBACK SIDE(S).40'-6"2'-0"13'-1112"COVER SHEET / SITE PLAN A1.0BURGOS RESIDENCEATLANTIC BEACH, FL 32233381 SEMINOLE ROAD345 South Roscoe Blvd.Ponte Vedra Beach, FL32082v.727.483.2422copyright DRAWING TITLERAE04.02.24 BURGOS c DATE CLIENT REVISIONS SHEET NO. JOB NO. 2318 NO.DESCRIPTION DATE AR97282 R S C OTT RAEdesign 16070 GARAGE DOOR FIRST FLOOR PLAN11/4" = 1'-0" UP AS-BUILT 1 A4.1 EXISTING COVERED LANAI EXISTING 2-CAR GARAGE EXISTING FAMILY ROOM EXISTING FLEX AREA EXISTING KITCHEN EXISTING LIVING ROOM NOTE: NO CHANGES @ EXISTING FIRST FLOOR LEVEL EXIST. WIN.EXIST. WIN. EXIST. WIN.EXIST. WIN. SECOND FLOOR PLAN21/4" = 1'-0" AS-BUILT DN EXISTING FAMILY ROOM EXISTING COVERED LANAI ROOF EXISTING BEDROOM EXISTING BEDROOM EXISTING PRIMARY BEDROOM EXISTING W.I.C. EXISTING PRIMARY BATHROOM EXISTING BATHROOM EXISTING HALL (VUALTED CEILING) EXISTING STAIR EXISTING 2-CAR GARAGE ROOF SECOND FLOOR PLAN31/4" = 1'-0" DN TV EXISTING BEDROOM TV EXISTING BEDROOM BALCONY 1'-1012"EXISTING HOUSEBENCH 9'-10"10'-2"11'-412"11'-412"1 A4.1 LEGEND: EXISTING WALL 35'-21 2" NEW WALL 6'-614"7'-2" 20'-212" 6'-614" 15'-0"40'-6"8'-1134"19'-1034"11'-712"37'-4" 7'-3"11'-0"11'-4"5'-71 2"42'-412"1'-1012"5'-6"35'-0"13'-10"7'-2"14'-0"2'-112" 2846 SH HDR @ 7'-6" AFF 2846 SH HDR @ 7'-6" AFF EXISTING COVERED LANAI ROOF 30803080(E X I S T )(EXIST)RISE/RUN VIF (8' CLG)(8' CLG)1'-1012"2'-0"3'-1012"512"15'-012"512"EXIST. WIN.EXIST. WIN.EXIST. WIN.EXIST. WIN. EXIST. WIN. EXIST. WIN.SLOPE18" PER FT.+3' RAIL EXISTING BATHROOM DRESSINGPRIMARY BEDROOM (9' CLG) TV PRIMARY BATHROOM (9' CLG) LAUNDRY LINEN W.I.C. (9' CLG) D WSHOWER2868DESK OFFICE / FUTURE BEDROOM (8' CLG) EXISTING ROOF LINE OF EXISTING ROOF LINE OF EXISTING ROOF6020 FGHDR @ 7'-6" AFFROOFSLOPEEXIST.TYP.312"6'-1112"312"3'-0"13'-012"3'-0"312"4'-3"3'-812"312"13'-0"512"512" 5'-714" 7'-91 2" 14'-434" 5'-0"5'-812" 3'-112"6'-7"4'-0" 13'-812"7'-6"312"3'-2"312"2'-312"10'-812"5'-7" 31 2" 3'-612" 31 2" 4'-0"6'-1112"3'-61 2" 3'-10"5'-7" 5'-6" 3'-4" 31 2"2'-0"312" 5'-71 4" 51 2"2X6 WALLPER SECTION 24-172(C)(1), SECOND AND THIRD STORY EXTERIOR WALLS WHICH EXCEED 35' IN LENGTH, SHALL PROVIDE HORIZONTAL OFFSETS 2' (DRIP EDGE) @ SIDE YARD SETBACK SIDE(S). 1'-0"2'-0"13'-1112"1'-0"24'-612"ATTENTION: ALL WINDOW HEAD HEIGHTS ARE MEASURED FROM MAIN FINISH FLOORS AS INDICATED AT ELEVATIONS, NOT FROM GARAGE FLOOR OR GARAGE CURB, TYP. ATTENTION: SHOWER HEADS @ 7' ABOVE SHOWER FLOOR, TYP. NOTES: 1. ALL EXTERIOR WALLS ARE 2X6 EXCEPT AS NOTED. 2. ALL INTERIOR WALLS ARE 2X4 EXCEPT AS NOTED. 3. ALL WALL THICKNESSES ARE ACTUAL 2X4 = 3 1 2", 2X6 = 5 1 2", 2xTHE SIZE AND QUANTITY OF ALL EXTERIOR STEPS ARE TO BE FIELD DETERMINED BY OTHERS. 5. ALL PLATE AND CEILING HEIGHTS ARE TAKEN FROM (TOP OF) HOUSE SLAB/BLOCK. 6. VERIFY THE KITCHEN AND VANITY LAYOUTS WITH THE DETAILS DONE BY OTHERS. 7. ALL INTERIOR AND EXTERIOR FLOOR & STEPS SHALL HAVE A NON-SLIP FINISH TO MEET ASTM C1028 STATIC COEFFICIENT OF FRICTION MIN. OF 0.6. 8. ALL WOOD IN CONTACT WITH MASONRY, CONCRETE OR EARTH SHALL BE PRESSURE TREATED APPROPRIATELY FOR THE CONDITION. 9. T = GLASS TO BE TEMPERED 10. E = EMERGENCY ESCAPE AND RESCUE OPENINGS 11. C = 20 MIN. FIRE RATED DOOR AREA TABULATION: BLDG SF TABULATION: 1ST FLOOR LIVING EXISTING 949 SF (A/C SF) 2ND FLOOR EXISTING 749 SF (A/C SF) 2ND FLOOR ADDITION 334 SF (A/C SF) TOTAL 2,032 SF (A/C SF) 2-CAR GARAGE 400 SF FRONT PORCH 16 SF TOTAL WITH ADDITION 2,448 SF NOTE: EXISTING TOTAL SF = 2,114 SF PER DUVAL COUNTY PROPERTY APPRAISER 1ST & 2ND FLOOR PLAN A2.1BURGOS RESIDENCEATLANTIC BEACH, FL 32233381 SEMINOLE ROAD345 South Roscoe Blvd.Ponte Vedra Beach, FL32082v.727.483.2422copyright DRAWING TITLERAE04.02.24 BURGOS c DATE CLIENT REVISIONS SHEET NO. JOB NO. 2318 NO.DESCRIPTION DATE AR97282 R S C OTT RAEdesign ROOF PLAN11/4" = 1'-0" ROOF ATTIC/VENTILATION AREA CALCULATIONS: EXCERPT OF THE 2020 FLORIDA BUILDING CODE, RESIDENTIAL R806: R806.1 VENTILATION REQUIRED: ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATED SPACE BY VENTILATING OPENINGS AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM TO 1/4 INCH (6.4 MM) MAXIMUM OPENINGS. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4 INCH (6.4 MM) SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH SCREENING. HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM AND 1/4 INCH (6.4 MM) MAXIMUM. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQUIREMENTS OF SECTION R802.7 REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO OUTSIDE AIR. R806.2 MINIMUM VENT AREA: THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/300 OF THE VENTED SPACE PROVIDED ONE OR MORE OF THE FOLLOWING CONDITIONS ARE MET: 1. IN CLIMATE ZONES 6, 7, & 8, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2. AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FT. (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICT WIT THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FT. (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. NOTE: NO VENTING PROVIDED IN LIVING AREAS DUE TO SPRAY FOAM INSULATION. NOTE: 1. ROOF OVERHANGS 16" UNLESS NOTED OTHERWISE. 2. ROOF PITCH = MATCH EXISTING UNLESS NOTED OTHERWISE. 3. ROOF FRAMING TO BE WOOD TRUSSES SET @ ( ) " O.C.. 4. ROOF FRAMING LUMBER TO BE #2 OR BETTER 5. INDICATES DIRECTION OF ROOF SLOPE.EXISTING COVERED LANAI ROOF ROOFSLOPEEXIST.TYP.2'-0"1'-6"2'-0"1'-6" 6" ACCENT ROOF OVER 2ND FLOOR BALCONY ROOF SLOPE 7:12 ROOF SLOPE 7:12 NEW ROOF AREA (HATCHED) NEW ROOF AREA (HATCHED) NEW ROOF AREA (HATCHED) NEW ROOF AREA (HATCHED)ROOFSLOPEEXIST.TYP.ROOFSLOPEEXIST.TYP.ROOFSLOPEEXIST.TYP.ROOFSLOPEEXIST.TYP.ROOFSLOPEEXIST.TYP.ROOFSLOPEEXIST.TYP.NEW ROOF AREA (HATCHED) OVER-FRAME HERE AS REQUIRED EXISTING RIDGE EXISTING RIDGE EXISTING RIDGE 2'-0" PER SECTION 24-172(C)(1), SECOND AND THIRD STORY EXTERIOR WALLS WHICH EXCEED 35' IN LENGTH, SHALL PROVIDE HORIZONTAL OFFSETS 2' (DRIP EDGE) @ SIDE YARD SETBACK SIDE(S). KICK-OUT FLASHING EXTERIOR STUD>. HGT. PER SPEC. DRIP EDGE DETAIL5N.T.S. SHINGLE ROOFING ROOF SHEATHING PER SPECIFCATIONS 2-LAYER SYNTHETIC FELT DRY-IN PAINTED METAL EAVE DRIP; EXTEND BACK MIN. 2" 1 X 2 P.T. FURRING FASCIAROOF TO WALL4N.T.S. (ROOF PARALLEL TO WALL) KICK-OUT FLASHING 7 N.T.S. WALL TO ROOF6N.T.S. SIDING PER ELEVATIONS SIDING PER ELEVATIONS FINISH OVERLAPPING TOP OF HEAD FLASHING 5X5 HEAD FLASHING WITH TOP ZIP TAPED TO ZIP SHEATHING COMPOSITE SHINGLE ROOFING 2-LAYER SYNTHETIC FELT DRY-IN EXISTING WOOD FRAME SYSTEM ZIP BOARD WALL SHEATHING SIDING PER ELEVATIONS 5X5 METAL HEAD FLASHING 2-LAYER SYNTHETIC FELT DRY-IN 2" SEE ELEV KICK-OUT SHINGLE ROOFING PER SPEC. FASCIA HOLD BACK FASCIA AND DRIP EDGE 2" FROM FACE OF WALL OUTSIDE FACE OF EXTERIOR WALL EXTERIOR FINISH PER ELEVATIONS FASCIA METAL DRIP EDGE OUTSIDE FACE OF EXTERIOR WALL EXTERIOR WALL SHEATHING (WRB) WEATHER RESISTANT BARRIER 5X5 FLASHING W/ KICK-OUT TO SHED WATER AWAY FROM HOUSE,TYP. (WRB) OVERLAPS THE 5X5 FLASHING ROOF SHEATHING VALLEY 2 N.T.S. METAL VALLEY FLASHING ROOF SHEATHING W/ PLYCLIPS COMPOSITE SHINGLE ROOFING 2-LAYERS OF SYNTHETIC FELT ROOF OPENING AND OFF-RIDGE VENT3N.T.S. NOTES: 1 - INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS 2 - APPLY ROOFING CEMENT OR SELF-ADHERING FLASHING OVER FLANGE AT HEAD ONLY COMPOSITE SHINGLE ROOFING SEAL VENT FLANGE AT HEAD GALVANIZED METAL OFF-RIDGE VENT, SET IN PLASTIC ROOF CEMENT OR SEALANT OR OFF-RIDGE VENT FLANGE OVER SHINGLE ROOFING AT BASE SHEATHING OVER ROOF MEMBERS PER ENG'S DETAILS ROOF VENT / PIPE OR INSTALL ROOF VENT/PIPE OVERLAP SHINGLE FLASHING FLASHING FLASHING ROOF PLAN A2.2BURGOS RESIDENCEATLANTIC BEACH, FL 32233381 SEMINOLE ROAD345 South Roscoe Blvd.Ponte Vedra Beach, FL32082v.727.483.2422copyright DRAWING TITLERAE04.02.24 BURGOS c DATE CLIENT REVISIONS SHEET NO. JOB NO. 2318 NO.DESCRIPTION DATE AR97282 R S C OTT RAEdesign 6"8'-0"9'-0"PLATE HT. @ 2ND FL ADDITIONF.F. @ FIRST FLOOR1'-4"F.F. @ SECOND FLOOR 1 1/4" = 1'-0" FRONT ELEVATION11/4" = 1'-0" COMP. SHINGLE ROOF 12 7ACCENT ROOF CEMENT BOARD & BATTEN SIDING CEMENT BOARD LAP SIDING CEMENT BOARD SHAKE SIDING (EXISTING) +3' RAIL NEW BALCONY OFF PRIMARY BEDROOM (NEW)(NEW)(NEW) (EXISTING)(EXISTING)(EXISTING) (EXISTING)(EXISTING)EXISTING ROOF 26'-114"T.O. ROOF PER SECTION 24-172(C)(1), SECOND AND THIRD STORY EXTERIOR WALLS WHICH EXCEED 35' IN LENGTH, SHALL PROVIDE HORIZONTAL OFFSETS 2' (DRIP EDGE) @ SIDE YARD SETBACK SIDE(S). 2'-0"26'-114"6"8'-0"9'-0"F.F. @ FIRST FLOOR1'-4"T.O. ROOF F.F. @ SECOND FLOOR 1/4" = 1'-0" RIGHT SIDE ELEVATION21/4" = 1'-0" COMP. SHINGLE ROOF EXISTING COVERED LANAI 12 VIF TYP. CEMENT BOARD LAP SIDING CEMENT BOARD SHAKE SIDING (EXISTING) CEMENT BOARD & BATTEN SIDING +3' RAIL 2 6 2 626 2 6 2 6 2 8 2 8 22 6 SLOPE 2% MIN. TYPICAL ROOF DECK FRAMING COMP. ROOF O/ ROOF SHEATHING PER STRUCT. O/ PRE-MANUFACTURED ROOF TRUSSES O/ INSTALL PER MFG. SPEC. O/ 12" G.W.B. TYPICAL FLOOR FRAMING FLOOR FINISH T.B.D. O/ UNDERLAYMENT T.B.D. O/ FLOOR SHEATHING PER STRUCT.O/ FLOOR JOISTS PER STRUCT. O/ 12" G.W.B. 22 GA. GALV. HEAD FLASHING (PAINT);; LAP UNDER BLDG PAPER; SLOPE AWAY FROM WALL @ 0.25:12 MIN. 5/4X4 CEMENT BD WINDOW TRIM WHERE LAP SIDING OCCURS; SLOPE AWAY FROM WALL @ 0.25:12 MIN. WINDOW HEAD W/ NAILING FLANGE; INSTALL PER MFG. SPEC.; LAP INTO BLDG. PAPER; TYP. WINDOW SIL W/ NAILING FLANGE; INSTALL PER MFG. SPEC.; LAP INTO BLDG. PAPER; TYP. RIM JOIST OR BEAM PER STRUCT. R-21 BATT INSULATION @ EXT. WALL W/IN FLOOR CAVITY R-21 INSULATED WINDOW HEADER PER STRUCT. TYPICAL EXTERIOR WALL EXTERIOR SIDING PER ELEVATION O/ WATERPROOF BLDG. PAPER O/ SHEATHING PER STRUCT. O/ 2X6 STUDS @ 16" O.C. W/ R-21 BATT INSULATION & VAPOR BARRIER (WARM SIDE) O/ 12" G.W.B. TYPICAL FIRST FLOOR S.O.G. ASSEMBLY FLOOR FINISH T.B.D. O/ UNDERLAYMENT T.B.D. O/ 4" CONC. S.O.G. PER STRUCT. O/ 2" R-10 RIGID INSULATION O/ 6 MIL POLYETHELENE VAPOR BARRIER O/ 6" FREE DRAINING GRAVEL O/ FIRM NATIVE SOILS 22 GA. GALV. DRIP EDGE; LAP UNDER BLDG PAPER; TYP. @ HORIZONTAL LEDGES AND CHANGES IN SIDING 4" PERFORATED DRAIN TILE W/ FABRIC FILTER; TYP. @ EXTERIOR FOOTINGS; CONNECT TO STORM DRAIN SYSTEM 6" MIN. FREE DRAINING GRAVEL AROUND DRAIN TILE; TYP. CONC. FOOTING AND FOUNDATION WALL PER STRUCT. WALL SECTION, TYP.3 3/4" = 1'-0" 25/4X4 CEMENT BD WINDOW TRIM WHERE LAP SIDING OCCURS; SLOPE AWAY FROM WALL @ 0.25:12 MIN.PER STRUCT.18" MIN.2 X 12 STRINGER; SIDE CARRIAGES SUPPORTED CONT. ON ADJ. WALLFRAMING 23'-0"TYP.WOOD TREAD 7 3/4"MAX.2 HEAD STAIR SECTION51/2" = 1'-0" TOP / LANDING INSTALL CONTINUOUS 36" CS14 @ EACH STRINGER LOCATION PRIOR TO STAIR INSTALLATION TO ALLOW FOR PROPER NAILING, TYP.6"4"SPHERE MAX. SPHERE MAX. 10"1"NOSING STANDARD 1" TREADS 10" 2 2 2 2 X 12 STRINGER; SIDE CARRIAGES SUPPORTED CONT. ON ADJ. WALLFRAMING 2 2 FOOT 7 3/4"MAX.STAIR SECTION41/2" = 1'-0" BOTTOM3'-0"(BY OTHERS) - 2" X 3/8" CONT. PWDR COATED STL. GUARDRAIL, TYP. STL. STL. CABLE, TYP.6"SPHERE MAX. 4"SPHERE MAX. 1" NOSING1"STANDARD 1" TREADS 2 2 2 2 EXTERIOR ELEVATIONS A3.1BURGOS RESIDENCEATLANTIC BEACH, FL 32233381 SEMINOLE ROAD345 South Roscoe Blvd.Ponte Vedra Beach, FL32082v.727.483.2422copyright DRAWING TITLERAE04.02.24 BURGOS c DATE CLIENT REVISIONS SHEET NO. JOB NO. 2318 NO.DESCRIPTION DATE AR97282 R S C OTT RAEdesign 1 1/4" = 1'-0" REAR ELEVATION11/4" = 1'-0" COMP. SHINGLE ROOF EXISTING COVERED LANAI 12 7 CEMENT BOARD LAP SIDING (EXISTING)(EXISTING)(EXISTING) (EXISTING) (EXISTING)(EXISTING)(EXISTING)6"8'-0"8'-0"F.F. @ FIRST FLOOR1'-4"F.F. @ SECOND FLOOR26'-114"T.O. ROOF 1/4" = 1'-0" LEFT SIDE ELEVATION21/4" = 1'-0" COMP. SHINGLE ROOF EXISTING COVERED LANAI CEMENT BOARD LAP SIDING CEMENT BOARD LAP SIDING +3' RAIL (EXISTING) (EXISTING) (NEW)6"8'-0"8'-0"F.F. @ FIRST FLOOR1'-4"F.F. @ SECOND FLOOR26'-114"T.O. ROOF 12 VIF TYP. PER SECTION 24-172(C)(1), SECOND AND THIRD STORY EXTERIOR WALLS WHICH EXCEED 35' IN LENGTH, SHALL PROVIDE HORIZONTAL OFFSETS 2' (DRIP EDGE) @ SIDE YARD SETBACK SIDE(S). WINDOW INSTALLATION 3 1/2" = 1'-0" NOTE: WEATHER RESISTIVE BARRIER (WSB) APPLIED PRIOR TO THE WINDOW INSTALLATION. FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE. STEPS: 1.IN THE WATER SHEDDING FASHION, STARTING AT THE BASE OF THE WALL & WORKING TOWARDS THE TOP, INSTALL THE WRB TO THE FACE OF THE SHEATHING 2.APPLY SILL FLASHING. 3.APPLY BEAD OF SEALANT AT BACK OF WINDOW FLANGE & SET WINDOW USING PAN HEAD SCREWS TO FACILITATE INSPECTION. 4.APPLY BEAD OF SEALANT AT SIDE JAMBS, EXTEND 8 12" 5.APPLY JAMB FLASHING. 6.APPLY BEAD OF SEALANT AT HEAD. 7.APPLY HEAD FLASHING. 8.REMOVE PREVIOUSLY APPLIED TAPE, ALLOWING WRB TO LAY FLAT OVER HEAD FLASHING. APPLY NEW SHEATHING TAPE OVER DIAGONAL CUT - SEE DIAGRAM. 2 6 2 6 5.JAMB FLASHING: APPLY CONT. SEAL TO THE MOUNTING FLANGES AT THE TOP (HEAD) AND SIDES (JAMB) OF WINDOW. EXTEND SEALANT AT JAMBS 8 12" ABOVE THE R.O. AT HEAD. EMBED JAMB FLASHING INTO SEALANT AND FASTEN IN PLACE. (FLASHING GOES OVER SEALANT.) SEAL THE WINDOW FRAME TO OPENING. APPLY A 3 8" NOM. DIA. TO THE BACKSIDE (INTERIOR) OF THE WINDOW FLANGE, IN LINE WITH ANY PRE-PUNCHED HOLES OR SLOTS. SEALANT BEAD BEHIND MOUNTING FLANGE SECTION A THROUGH WINDOW JAMB SEALANT BEAD BETWEEN FLASHING AND MOUNTING FLANGE FLASHING SECURE WRB @ HEAD 8. 7. 5. 3. 2. 1. 5. FLASHING AT HEAD EXTENDS 1" BEYOND JAMB FLASHING. 7.HEAD FLASHING: EMBED BOTTOM OF THE HEAD FLASHING AGAINST THE PREVIOUSLY APPLIED SEALANT (FLASHING GOES OVER SEALANT). EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. 5.JAMB FLASHING: EXTEND JAMB FLASHING TO OVERLAP SILL FLASHING. EXTEND JAMB FLASHING 8 12" ABOVE ROUGH OPENING AT HEAD. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. SEE DIAGRAM. SILL FLASHING. SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE, PLUMB AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PER WINDOW MANUFACTURER SPECIFICATIONS. 1.WEATHER RESISTANT BARRIER (WRB): AT A 45 DEGREE ANGLE, CAREFULLY CUT THE BARRIER ON A DIAGONAL. GENTLY RAISE THE TOP EDGE OF THE BARRIER UP AND TAPE THE TOP CORNERS AND CENTER TO THE EXTERIOR WRB SURFACE ABOVE. 8. 1. CUT LINE 8 12" SEALANT 8. A A SEALANT INTERIOR VIEW TOP LEFT CORNER OF WINDOW NOTE: ALL FLASHING WILL BE SELF ADHEARING AND ROLLED SMOOTH AND FLAT WITH A J-ROLLER. WRB WRB 1 WRB WRB WRB WRB WRB45°CUT EXTERIOR DOOR FLASHING4N.T.S. 2 3 4 5 6 WRB WRB WRB 9"9"8"WRAP WRB INTO OPNG. MODIFIED "J" CUT IN WRB REMOVE BOTTOM WRB FLAP TEMPORARILY TAPE UP TOP FLAP INSTALL VULKUM @ THRESHHOLD PER MFG. INSTRUCTIONS; INSTALL DOOR, SHIM DOOR TO LEVEL; PLUMB AND SQUARE DOOR TO OPENING APPLY JAMB FLASHING TO BOTH SIDES OF DOOR TO DOOR FRAME TO WRB EXTENDING 8" ABOVE DOOR ROUGH OPENING APPLY HEAD FLASHING, EXTENDING 10" BEYOND DOOR ROUGH OPENING UNFOLD TOP FLAP AND COVER DIAGONAL CUT IN WRB WITH SHEATHING TAPE FASTEN ZIP SYSTEM ® SHEATHING AS REQUIRED BY ENGINEER-OF-RECORD AND/OR LOCAL BUILDING CODE ZIP WALL CEMENT BOARD5N.T.S. WALL ASSEMBLY: CEMENTITIOUS VENEER W/ CNTRL JOINTS PER CODE; SIDING INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION RECOMMENDATIONS; ZIP SYSTEM ® SHEATHING O/ WOOD STUDS 1/8" GAP RECOMMENDED @ PANEL EDGES, TYP. ZIP SYSTEM ® TAPE (INSTALLED OVER ALL JOINTS IN ZIP SYSTEM ® SHEATHING) OVERLAP TAPE A MINIMUM OF 1" @ ALL T-JOINTS 1/8" GAP RECOMMENDED @ PANEL EDGES,TYP. LAP SIDING DTL. EXTERIOR ELEVATIONS A3.2BURGOS RESIDENCEATLANTIC BEACH, FL 32233381 SEMINOLE ROAD345 South Roscoe Blvd.Ponte Vedra Beach, FL32082v.727.483.2422copyright DRAWING TITLERAE04.02.24 BURGOS c DATE CLIENT REVISIONS SHEET NO. JOB NO. 2318 NO.DESCRIPTION DATE AR97282 R S C OTT RAEdesign ELECTRICAL NOTES: 1. ALL OUTLETS IN BEDROOM TO BE "A.F.I." 2. ALL EXTERIOR OUTLETS TO BE "G.F.I." 3. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH ARTICLE 80 OF NFPA 70A 4. NOTE: 100% HIGH EFFICACY LIGHTING 5. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNITS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED AFCI, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER 210.12(B) ATTENTION: CENTER OF BOXES OF ALL VANITY LIGHTS TO BE AT 7'-8" AFF, EXCEPT 8'-6" IN OWNER'S BATH SURFACE MOUNTED CEILING FIXTURE RECESSED WATER PROOF CEILING FIXTURE SCONCE UNDER CABINET LED STRIP LIGHTING RECESSED CEILING FIXTURE 110 V. DUPLEX OUTLET 110 V. WATER PROOF DUPLEX OUTLET W/ GFI 220 V. OUTLET EXHAUST FAN 110 V. SMOKE / CO2 DETECTOR WATER HEATER THERMOSTAT DATA (18" AFF) LIGHT SWITCH 3-WAY LIGHT SWITCH LIGHT SWITCH WITH DIMMER ELECTRICAL LEGEND SYMBOL DISCRIPTION WP WP/GFCI T WH D S 3S DS NOTES: 1. PER FBC-R E3902.10; THE BRANCH CIRCUIT FOR THE DISHWASHER SHALL HAVE A GROUND-FAULT CIRCUIT INTERRUPTER, TYP. 2. PER FBC-R E3902.16; BRANCH CIRCUITS IN THE KITCHEN, LIVING ROOM, DINING ROOM, HALLWAYS, BEDROOMS, LAUNDRY AREA, ENTRY FOYER, STAIRWAY, CLOSETS AND OTHER SIMILAR AREAS SHALL HAVE A ARC-FAULT CIRCUIT INTERRUPTER PROTECTION, TYP. 3. PER FBC-R E 4002.14; RECEPTACLES TO BE TAMPER-RESISTANT, TYP. EXTERIOR FLOOD FIXTURE - MOTION SENSOR EXHAUST FAN W/ LIGHT 110 V. WATER PROOF DUPLEX OUTLET W/ GFI ON GROUND FAULT CIRCUIT GFCI 220 GFCI SD/CO2 CABLE TV OUTLETTV WAP WIRELESS ACCESS POINT SURF. MOUNTED HANGNING PENDANT FIXTURE EXTERIOR FLOOD LIGHT 110 V. QUAD OUTLET FLOOR OUTLET GARAGE DOOR PUSH BUTTON THERMOSTATT SECOND FLOOR RCP/ELEC11/4" = 1'-0" DN TV EXISTING BEDROOM TV EXISTING BEDROOM BALCONY BENCH EXISTING COVERED LANAI ROOF (8' CLG)(8' CLG) EXISTING BATHROOM DRESSINGPRIMARY BEDROOM (9' CLG) PRIMARY BATHROOM LAUNDRY LINEN W.I.C. (9' CLG) D W SHOWER DESK OFFICE / FUTURE BEDROOM (8' CLG) EXISTING ROOF LINE OF EXISTING ROOF LINE OF EXISTING ROOF S SSSS EXISTING HALL SD/CO2 SSTVDTVDSHOWER WP SSSGFCIGFCIGFCI SS GFCI 220 GFCI GFCISSD/CO2 SD/CO2 1ST & 2ND RCP/ELEC. A4.1BURGOS RESIDENCEATLANTIC BEACH, FL 32233381 SEMINOLE ROAD345 South Roscoe Blvd.Ponte Vedra Beach, FL32082v.727.483.2422copyright DRAWING TITLERAE04.02.24 BURGOS c DATE CLIENT REVISIONS SHEET NO. JOB NO. 2318 NO.DESCRIPTION DATE AR97282 R S C OTT RAEdesign