Loading...
703 SELVA LAKES CIR POOL24-0009 Equipment Specs WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. ATTENTION INSTALLER - This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment. INSTALLATION AND OPERATION MANUAL VSFHP185DV2AVSFHP270DV2AVSPHP270DV2AVSSHP220DV2AVSSHP270DV2A Jandy Variable-Speed Pumps ENGLISH | FRANÇAIS | ESPAÑOL Page 23 ENGLISH Jandy® Variable-Speed Pumps | Installation & Operation Manual 7.2 Performance Curves 100 3450 RPM 3000 RPM 115 VAC 2750 RPM 2400 RPM 1730 RPM 1200 RPM 600 RPM 90 80 70 60 50 40 30 20 10 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 1600 0 VSPHP270DV2A Performance Curves Total Dynamic Head (Feet of Water)Flow Rate, Gallons Per Minute (GPM) 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160)retaW fo teeF( daeH cimanyD latoTFlow Rate, Gallons Per Minute (GPM) VSFHP270DV2A Performance Curves 600 RPM 1200 RPM 1730 RPM 2400 RPM 2750 RPM 3000 RPM 3450 RPM 115 VAC Page 24 ENGLISH Jandy® Variable-Speed Pumps | Installation & Operation Manual 0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160)retaW fo teeF( daeH cimanyD latoTFlow Rate, Gallons Per Minute (GPM) VSFHP185DV2A Performance Curves 600 RPM 1200 RPM 1730 RPM 2400 RPM 2750 RPM 3000 RPM 3450 RPM 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200Total Dynamic Head (Feet of Water)Flow Rate, Gallons Per Minute (GPM) VSSHP220DV2A Performance Curves 3450 RPM 2400 RPM 2800 RPM 3000 RPM 1730RPM 1200 RPM 600 RPM 115VAC Page 25 ENGLISH Jandy® Variable-Speed Pumps | Installation & Operation Manual 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200Total Dynamic Head (Feet of Water)Flow Rate, Gallons Per Minute (GPM) VSSHP270DV2A Performance Curves 3450 RPM 2400 RPM 2800 RPM 3000RPM 1730 RPM 1200 RPM 600RPM 115VAC Installation and Operation Manual Jandy® Cartridge Pool Filters CL and CV Versa-Plumbâ„¢ Series Filters WARNING FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/spa service technician. The procedures in this manual must be followed exactly. Improper lid to be blown off, possibly causing death, serious injury or property damage. Improper installation and/or operation will void the warranty. Before installing this product, read and follow all warning notices and instructions that property damage, serious injury, or death. Installation and Operation Data Page 5Cartridge Pool Filters - CL and CV Series Filters Section 2. General Information 2.1 Introduction This manual contains information for the proper instal- lation and operation of the Jandy® CL and CV Series Cartridge Filters. Procedures in this manual must be followed exactly. To obtain additional copies of this manual contact us at 707.776.8200 ext. 237. For address information see back cover. 2.2 Description replacement. line connected to the lower bulkhead (inlet) on the bottom half of the tank body. It is directed through the through the upper bulkhead (outlet) on the bottom half of the tank body. Clean water is returned through the piping system to the pool. eventually become so plugged with debris that it will be with soap and water. NOTE but does not sanitize the pool. Pool water must be sanitized and chemically balanced for clear water. local health codes. At a minimum, the system should turnover the total volume of water in your pool two to 2.3 General Requirements 1. For best overall performance place the system as close to the pool as possible. slab so that the orientation of the valve outlets and the pressure gauge are convenient and accessible for the installation and operation of the unit. exercised to ensure that the appliance is installed in accordance with the Manufacturer’s Instructions and any standards that may exist. 5. We recommend the use of barrel unions to connect each component of the water conditioning system to ease in future servicing. Barrel unions are CL/CV 340 460 580 Filter Area (ft2) Max. Flow (gpm) 127 Six Hour Capacity (gal.) Max. Working Pressure (psi) Normal Start Up Pressure (psi) Dimension "A" Figure 1. Dimensions, Jandy CL and CV Series Cartridge Filters WARNING psi. Never subject the filter to operating pressure can cause the lid to be blown off, which can result in death, serious personal injury, or property damage. 6. When performing hydrostatic pressure tests or when testing for external leaks of the completed subjected to does not exceed the maximum working pressure of any of the components within the system. See Table 1 and Figure 1. 18 ½ in 10 ½ in 28 in "A" CL INLET OUTLET CV INLET Port on CV Model Only Port on CL Model Only ® 32" CHANNEL DRAIN25506-32X-00 IAPMO Listed VGB Suction: Compliant to ANSI/APSP - 16 2017 & CPSC Requirements All Custom Molded Products main drains are listed and tested in strict accordance to the requirements of ANSI/APSP - 16 2017, the current standard of reference for the Virginia Graeme Baker Act, and compliant to the latest Consumer Product Safety Commission (CPSC) requirements. VGBA TESTED & CERTIFIED ANSI-APSP 16 | CPSC 5 B. SIZING & SPECIFICATION REFERENCE TOTAL HEAD LOSS (Feet of Head)FLOW RATE (GPM) -4 0 50 100 150 200 250 300 -2 0 2 4 6 8 10 -1.92 2.42 3.83 6.14 9.02 -2.6 -0.92 0.24 4.56 9.55 CENTER PORT, 2.5IN PIPE CENTER PORT, 2IN PIPE TOTAL HEAD LOSS (Feet of Head)FLOW RATE (GPM) -5 0 50 100 150 200 250 300 350 400 0 5 10 15 20 25 30 -0.2 2.4 5.97 12.09 18.36 2.1 5.5 8.46 16.42 28.33 OUTER PORTS, 2.5IN PIPE OUTER PORTS, 2IN PIPE CHART 1: HEAD LOSS CHARTS