FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment.
INSTALLATION AND OPERATION MANUAL
VSFHP185DV2AVSFHP270DV2AVSPHP270DV2AVSSHP220DV2AVSSHP270DV2A
Jandy
Variable-Speed Pumps
ENGLISH | FRANÇAIS | ESPAÑOL
Page 23 ENGLISH Jandy® Variable-Speed Pumps | Installation & Operation Manual
7.2 Performance Curves
100
3450 RPM
3000 RPM 115 VAC
2750 RPM
2400 RPM
1730 RPM
1200 RPM
600 RPM
90
80
70
60
50
40
30
20
10
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 1600
0
VSPHP270DV2A Performance Curves
Total Dynamic Head (Feet of Water)Flow Rate, Gallons Per Minute (GPM)
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160)retaW fo teeF( daeH cimanyD latoTFlow Rate, Gallons Per Minute (GPM)
VSFHP270DV2A Performance Curves
600 RPM
1200 RPM
1730 RPM
2400 RPM
2750 RPM
3000 RPM
3450 RPM
115 VAC
Page 24 ENGLISH Jandy® Variable-Speed Pumps | Installation & Operation Manual
0
10
20
30
40
50
60
70
80
90
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160)retaW fo teeF( daeH cimanyD latoTFlow Rate, Gallons Per Minute (GPM)
VSFHP185DV2A Performance Curves
600 RPM
1200 RPM
1730 RPM
2400 RPM
2750 RPM
3000 RPM
3450 RPM
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200Total Dynamic Head (Feet of Water)Flow Rate, Gallons Per Minute (GPM)
VSSHP220DV2A Performance Curves
3450 RPM
2400 RPM
2800 RPM
3000 RPM
1730RPM
1200 RPM
600 RPM
115VAC
Page 25 ENGLISH Jandy® Variable-Speed Pumps | Installation & Operation Manual
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200Total Dynamic Head (Feet of Water)Flow Rate, Gallons Per Minute (GPM)
VSSHP270DV2A Performance Curves
3450 RPM
2400 RPM
2800 RPM
3000RPM
1730 RPM
1200 RPM
600RPM
115VAC
Installation and
Operation Manual
Jandy® Cartridge
Pool Filters
CL and CV Versa-Plumbâ„¢
Series Filters
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/spa service technician. The procedures in this manual must be followed exactly. Improper
lid to be blown off, possibly causing death, serious injury or property damage. Improper
installation and/or operation will void the warranty.
Before installing this product, read and follow all warning notices and instructions that
property damage, serious injury, or death.
Installation and Operation Data
Page 5Cartridge Pool Filters - CL and CV Series Filters
Section 2. General Information
2.1 Introduction
This manual contains information for the proper instal-
lation and operation of the Jandy® CL and CV Series
Cartridge Filters. Procedures in this manual must be
followed exactly. To obtain additional copies of this
manual contact us at 707.776.8200 ext. 237. For address
information see back cover.
2.2 Description
replacement.
line connected to the lower bulkhead (inlet) on the
bottom half of the tank body. It is directed through the
through the upper bulkhead (outlet) on the bottom half
of the tank body. Clean water is returned through the
piping system to the pool.
eventually become so plugged with debris that it will be
with soap and water.
NOTE
but does not sanitize the pool. Pool water must be
sanitized and chemically balanced for clear water.
local health codes. At a minimum, the system should
turnover the total volume of water in your pool two to
2.3 General Requirements
1. For best overall performance place the system as
close to the pool as possible.
slab so that the orientation of the valve outlets and
the pressure gauge are convenient and accessible
for the installation and operation of the unit.
exercised to ensure that the appliance is installed
in accordance with the Manufacturer’s Instructions
and any standards that may exist.
5. We recommend the use of barrel unions to connect
each component of the water conditioning system
to ease in future servicing. Barrel unions are
CL/CV 340 460 580
Filter Area (ft2)
Max. Flow (gpm) 127
Six Hour
Capacity (gal.)
Max. Working
Pressure (psi)
Normal Start Up
Pressure (psi)
Dimension "A"
Figure 1. Dimensions, Jandy CL and CV Series
Cartridge Filters
WARNING
psi. Never subject the filter to operating pressure
can cause the lid to be blown off, which can result in
death, serious personal injury, or property damage.
6. When performing hydrostatic pressure tests or
when testing for external leaks of the completed
subjected to does not exceed the maximum
working pressure of any of the components
within the system.
See Table 1 and Figure 1.
18 ½ in
10 ½ in
28 in
"A"
CL INLET
OUTLET CV INLET
Port on
CV Model
Only
Port on
CL Model
Only
®
32" CHANNEL DRAIN25506-32X-00
IAPMO Listed VGB Suction: Compliant to ANSI/APSP - 16 2017 & CPSC Requirements
All Custom Molded Products main drains are listed and tested in strict accordance to the requirements of ANSI/APSP - 16 2017, the current standard of reference for the Virginia Graeme Baker Act, and compliant to the latest Consumer Product Safety Commission (CPSC) requirements.
VGBA TESTED & CERTIFIED
ANSI-APSP 16 | CPSC
5
B. SIZING & SPECIFICATION REFERENCE
TOTAL HEAD LOSS (Feet of Head)FLOW RATE (GPM)
-4 0 50 100 150 200 250 300
-2
0
2
4
6
8
10
-1.92 2.42
3.83
6.14
9.02
-2.6 -0.92 0.24
4.56
9.55
CENTER PORT, 2.5IN PIPE CENTER PORT, 2IN PIPE
TOTAL HEAD LOSS (Feet of Head)FLOW RATE (GPM)
-5 0 50 100 150 200 250 300 350 400
0
5
10
15
20
25
30
-0.2
2.4
5.97
12.09
18.36
2.1
5.5
8.46
16.42
28.33
OUTER PORTS, 2.5IN PIPE OUTER PORTS, 2IN PIPE
CHART 1: HEAD LOSS CHARTS