Loading...
340 W 14TH ST ACC23-0031 - Site Plans-Update - No Utilities - ESS Rev. 1-11-24_1Sheet IndexVICINITY MAPPREPARED FOR:FONDER RESIDENCENORTH PLANSFORFONDER RESIDENCEDETAC*ED )ARA)E T* ST 9ATLANTIC $EAC* FLENGINEER:Cody & Joanna Fonder340 W 14th StAtlantic Beach, FLLegend Engineering416 3rd St S - Unit 202Jacksonville Beach, FL 32250813.389.0835legendenggroup.comPerritte Services904-955-6802Charles E. Porter2465 Stockton DrFleming Island, FL 32003904-234-5574CONSTRCUTOR:SURVEYOR:PROPERTY OWNER:DATE:AS SHOWNSCALE:NUMBER SHEETSPAGE NUMBERPROJECT No.1OCT 20231023-0340TITLEPLOT DATE:10/23/2023DRAWN BY:RCJDESIGNED BY:RCJCHECKED BY:JPREV DESCRIPTION DATEBYFONDER RESIDENCE DETACHED GARAGE ATLANTIC BEACH, FL1 of 5 WEST 14TH ST50' PUBLIC ROWASPHALT ROADWAY SURFACE W/ SIDEWALKS AND DITCHESLOT 1BLOCK 231LOT 2BLOCK 231LOT 3BLOCK 231VIOLET ST 50' PUBLIC ROWPROPOSEDDETACHEDGARAGE600 SQ FTFFE 12.3EX ONE STORYFRAME & SIDNINGRESIDNECE NO. 340FFE 13.9LOT 1BLOCK 231EX WATER SERVICEEX SEWER SERVICEDATE:SCALE:NUMBER SHEETSPAGE NUMBERPROJECT No.2SURVEY AND EROSION CONTROLDRAWN BY:RCJDESIGNED BY:RCJREV DESCRIPTION DATEBYSURVEYSCALE: 1" = 10'EROSION CONTROL AND DEMO PLANSCALE: 1" = 10'FILTER FENCE DETAIL6" MIN4'26" MINFINISHED GRADESTAKES: 2x2 (NOMINAL) HARDWOOD, 1 1/2" x 1 1/2" x 42" ACTUAL1/4" HARDWOOD LATH FASTENED TO STAKEDIRECTION OF FLOWSTAKE SPACING 4,5,6,7,8,9,10 FT. ON CENTERCIRCLE ONEGEOTEXTILE FILTER FABRIC EMBEDDEDMINIMUM OF 6" INTO GROUND WITH AMINIMUM OF 8" OF FABRIC BELOW GRADE1.SILT FENCE SHALL BE CONSTRUCTED BEFORE UPSLOPE GROUND COVER IS REMOVED. CLEARING, GRUBBING, AND STUMPING CANOCCUR BEFORE SILT FENCE INSTALLATION IF GROUND COVER IS NOT REMOVED.2.WHERE POSSIBLE, SILT FENCE SHALL BE PLACED ON THE FLATTEST AREA AVAILABLE.3.A RUN OF SILT FENCE SHOULD FOLLOW THE CONTOUR AS CLOSE AS POSSIBLE WITH THE ENDS TURNED UPSLOPE TO POND WATERBEHIND THE FENCE.4.THE SILT FENCE SHOULD BE BURIED AT LEAST 6" DEEP AND HAVE A TOTAL OF 8" OF FABRIC BELOW THE GROUND. THIS CAN BEACCOMPLISHED WITH A TRENCHER, CABLE LAYING MACHINE, SLICING MACHINE OR OTHER SUITABLE DEVICE WHICH WILL ENSURE ANADEQUATELY UNIFORM TRENCH DEPTH.5.THE STAKES SHALL BE PLACED ON THE DOWN SLOPE SIDE OF THE GEOTEXTILE. THE STAKES SHALL BE A MINIMUM OF 2X2 NOMINAL(1-1/2" X 1-1/2" ACTUAL) HARDWOOD STAKE OF SOUND QUALITY. T-POSTS MAY BE SUBSTITUTED IF GROUND CONDITIONS REQUIRE.6.WHERE TWO SILT FENCE SECTIONS ARE COMBINED INTO ONE RUN THE END STAKES SHALL BE CONNECTED TOGETHER, NOT SIMPLYOVERLAPPED.7.IF RUNOFF OVERTOPS THE SILT FENCE, FLOWS AROUND THE ENDS, OR IN ANY OTHER WAY BECOMES A CONCENTRATED FLOW, ONE OFTHE FOLLOWING SHALL BE PERFORMED, AS APPROPRIATE: 1) AN ADDITIONAL RUN OF SILT FENCE SHALL BE PLACED UPSTREAM, 2)THE LAYOUT OF THE SILT FENCE SHALL BE CHANGED, 3) ACCUMULATED SEDIMENT SHALL BE REMOVED, OR 4) OTHER PRACTICESSHALL BE IMPLEMENTED.8.THE MANUFACTURER SHALL SUBMIT A CERTIFICATION WITH EACH SHIPMENT OF SILT FENCE STATING THAT IT MEETS THEFOLLOWING SPECIFICATION REQUIREMENTS: MINIMUM TENSILE STRENGTH - 120 LBS.; MAXIMUM ELONGATION AT 60 LBS - 50%;MINIMUM PUNCTURE STRENGTH - 50 LBS.; MINIMUM TEAR STRENGTH - 40 LBS.; MINIMUM BURST STRENGTH - 200 PSI., APPARENTOPENING SIZE <=.84MM.; MINIMUM PERMITTIVITY 1X10-2SEC-1; ULTRAVIOLET EXPOSURE STRENGTH RETENTION - 70%.- SILT FENCE- GRAVELSITE PLAN LEGENDTSB0SCALE: 1" = 10'10520WESNAS SHOWN2 of 5TSBTSBTSBTSBTSBTSBTSBTSBTSBTSBTSBTSBTSBTSBTSBTSBTSBTSB TSB TSB TSB TSB TSB TSBTSBTSBTSBTSBTSBTSBTSBOCT 20231023-0340CHECKED BY:JPFONDER RESIDENCE DETACHED GARAGE ATLANTIC BEACH, FL WEST 14TH ST50' PUBLIC ROWASPHALT ROADWAY SURFACE W/ SIDEWALKS AND DITCHESLOT 3BLOCK 231VIOLET ST 50' PUBLIC ROWPROPOSEDDETACHEDGARAGE600 SQ FTFFE 12.3EX ONE STORYFRAME & SIDNINGRESIDNECE NO. 340FFE 13.9LOT 1BLOCK 23125.0'22.0'4.0'13.0' 13.5'18.0'33.0'5.0'5.0'5.0'34.8'5.0'30.0'10.0'36.0'25.0'16.3'12.0'10'x8' ROLL UP8.7'CONTRACTOR TO INSTALLSTAIR WITH 48" LANDING6.0'DATE:SCALE:NUMBER SHEETSPAGE NUMBERPROJECT No.3DRAINAGE PLANSDRAWN BY:RCJDESIGNED BY:RCJREV DESCRIPTION DATEBY AS SHOWNGEOMETRY PLANSCALE: 1" = 10'0SCALE: 1" = 10'10520WESNGEN NOTE1.ALL WORK WILL BE PERFORMED IN ACCORDANCE WITH COABSTANDARD DETAILS AND SPECIFICATIONS AND/OR AS ALLAPPLICABLE STATE AND LOCAL REGULATIONS.2.GUTTERS SHALL BE TIED INTO DOWNSPOUTS. ALL DOWNSPOUTSSHALL BE BE DIRECTED TOWARDS CITY RIGHT OF WAYS ORAREAS THAT DO NOT CAUSE FLOODING IMPACTS OR POTENTIALEROSION ISSUES TO THE SUBJECT PROPERTY AND NEIGHBORINGPROPERTIES.3.ALL TOPOGRAPHIC AND SITE BOUNDARY INFORMATION PROVIDEDBY CHARLES PORTER SURVEYORS.4.ALL SURFACES SHALL BE SLOPED AWAY FROM THE BUILDINGS5.ALL GRADING SHALL BE SUCH THAT POSITIVE DRAINAGE OCCURS3 of 5-4" NDS CORRUGATED PIPE-EXISTING TOPO CONTOUR-DIRECTION OF FLOW-DOWNSPOUT-PROPOSED TOPOGRAPHIC EL-CONCRETE-FRENCH GRAVEL DRAIN BED-POP-UP DRAIN EMITTER-GUTTER-FILTER FENCE00.0TSB00.0SITE PLAN LEGENDOCT 20231023-0340PLOT DATE:10/23/2023CHECKED BY:JPFONDER RESIDENCE DETACHED GARAGE ATLANTIC BEACH, FL WEST 14TH ST50' PUBLIC ROWASPHALT ROADWAY SURFACE W/ SIDEWALKS AND DITCHESLOT 3BLOCK 231VIOLET ST 50' PUBLIC ROWPROPOSEDDETACHEDGARAGE600 SQ FTFFE 12.3EX ONE STORYFRAME & SIDNINGRESIDNECE NO. 340FFE 13.9LOT 1BLOCK 231PROP STORMWATERPOND 1V = 219 FT³EX WATER SERVICEEX SEWER SERVICE10'x8' ROLL UPPROP STORMWATERPOND 2V = 125 FT³TOB(11.00)BOT(10.80)WEST 14TH ST50' PUBLIC ROWASPHALT ROADWAY SURFACE W/ SIDEWALKS AND DITCHESLOT 3BLOCK 231VIOLET ST 50' PUBLIC ROWPROPOSEDDETACHEDGARAGE600 SQ FTFFE 12.3EX ONE STORYFRAME & SIDNINGRESIDNECE NO. 340FFE 13.9LOT 1BLOCK 231PROP STORMWATERPOND 1V = 219 FT³10'x8' ROLL UPPROP STORMWATER POND 2 V = 125 FT³ TOB(11.00) BOT(10.80)DATE:SCALE:NUMBER SHEETSPAGE NUMBERPROJECT No.4DRAINAGE PLANDRAWN BY:RCJDESIGNED BY:RCJREV DESCRIPTION DATEBY AS SHOWNGRADING PLANSCALE: 1" = 10'DRAINAGE PLANSCALE: 1" = 10'0SCALE: 1" = 10'10520WESN0SCALE: 1" = 10'10520WESN4 of 5** SEE CALCULATIONS FOR DETAILED DRAINAGE VOLUMES **ALL GUTTERS SHALL BE CONNECTED TO DOWNSPOUTS AND ALLDOWNSPOUTS SHALL BE TIED INTO FRENCH DRAIN WITH 4" NDSCORRUGATED PIPEDRAINAGE CALCULATIONPRE-DEVELOPMENTLOT AREA (A) = 7,140 SFDESCRIPTION AREA LOT AREA "C" IMPERVIOUS 7,140 SF 0.92 1,500 SFRUNOFF VOLUMEV = CAR/12 V= (0.92 x 1,500 x 9.3) / 12 V = 1,070 CFREQUIRED STORAGE V = 1,070CFTREATMENT VOLUMEREQUIRED TREATMENT VOLUME: 1,070 CFPROVIDED TREATMENT VOLUME: 1,081 CFLOT COVERAGEPROPOSED RESIDENCE LOT 7,140 SFEXISTING RESIDENCE 900 SF 12.6%PROPOSED GARAGE600 SF 8.4%TOTAL IMPERVIOUS1,500 SF21%11.2011.1511.1011.2511.5011.5012.0012.0011.5011.0011.3011.50MATCH EXGRADE11.20TOB(11.50)BOT(11.20)-4" NDS CORRUGATED PIPE-EXISTING TOPO CONTOUR-DIRECTION OF FLOW-DOWNSPOUT-PROPOSED TOPOGRAPHIC EL-CONCRETE-FRENCH GRAVEL DRAIN BED-POP-UP DRAIN EMITTER-GUTTER-FILTER FENCE00.0TSB00.0SITE PLAN LEGENDOCT 20231023-0340PLOT DATE:10/23/2023CHECKED BY:JPFONDER RESIDENCE DETACHED GARAGE ATLANTIC BEACH, FLTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALEDBY RODERICK C. JACKSON, PEPRINTED COPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNED AND SEALED AND THESIGNATURE MUST BE VERIFIED ON ANY ELECTRONICCOPIES.POP-UP EMITTER DETAIL(TYP)SCALE: NTS WEST 14TH ST50' PUBLIC ROWASPHALT ROADWAY SURFACE W/ SIDEWALKS AND DITCHESBLOCK 231LOT 3BLOCK 231VIOLET ST 50' PUBLIC ROWPROPOSEDDETACHEDGARAGE600 SQ FTFFE 12.3EX ONE STORYFRAME & SIDNINGRESIDNECE NO. 340FFE 13.9LOT 1BLOCK 231EX WATER SERVICEEX SEWER SERVICE10'x8' ROLL UP10'x8' ROLL UP2'x4'LIGHT 2'x4' LIGHT 2'x4'LIGHT 2'x4' LIGHTOVERSIZED FANCONTRACTOR TOCOORDINATE FAN SIZINGGFCIELECTRIC NOTES1.THE ELECTRICAL SYSTEM SHALL HAVE A MINIMUM 200 AMP MAIN DISCONNECT ANDBREAKER PANEL (NATIONAL OR EQUAL). WIRING SHALL BE COPPER 3 WIRE ROMEX. WIRINGTO LIGHT FIXTIJRES SHALL ALSO HAVE A NEUTRAL WIRE. TELEPHONE WIRING SHALL BE 6PAIR COPPER. TV WIRING SHALL BE COAXIAL.2.ALL KITCHEN, BATH , LAUNDRY, GARAGE AND EXTERIOR RECEPTICLES SHALL BE ONCIRCUIT USING A GROUND FAULT INTERRUPTER BREAKER, EXCEPT ANY CIRCUITS ANGARAGE DEDICATED FOR LANDSCAPE , LIGHTING OR SPRINKLER CLOCKS OR APPLIANCES,I.E. SOFT WATER, VACUM, ETC.3.AJC/ UNITS SHALL HAVE FUSED DISCONNECT OR A HACR RATED BREAKER.4.OUTLETS HEIGHTS SHALL BE 12" ABOVE SLAB , UNLESS NOTED OTHERWISE, EXCEPT INGARAGE, 48" ABOVE SLAB. BATHS , 41" ABOVE SL.AB. KITCHEN A.ND UTILITY ROOMS , 45"ABOVE SLAB. ALL MEASUREMENTS TO BE TO BOTTOM OF BOX.5.RECESSED LIGHTS ABOVE TUBS AND SHOWERS SHALL HAVE VAPOR PROOF TRIMS. TRIMSFOR SQUARE HOUSINGS SHALL BE REGRESSED DROP OPAL. TRIMS BY FIREPLACE SHALL BEREGRESSED EYEBALL. OTHER TRIMS SHALL BE OPN CONE (GOLD).6.ELECTRICAL SHALL SUPPLY AND INSTAU. WHITE NROCKER• TYPE SWITCHES, WITHMATCHING PLATES SUCH AS LEVITON DECORA. USE MATCHING RECEPTICLES IN VISIBLELIVING AREAS.7.ALL FLUORESCENT FIXTURES SHALL HAVE SOFT WHITE TUBES AND BE SUPPLIED BYELECTRICIAN. H PROVIDE GROUNDING ELECTRODE: 20' OF #4 COPPER OR 40' OF #4REBBAR IN CONC. FTG. PER IRC 20068.PROVIDE SERVICE GROUND: #1/0 TO COLD WATER PER TABLE 250-94 OF THE NATLELECTRIC CODE. CEILING FAN OUTLET BOXES SHALL BE RIGIDLY SECURED IN PLACE J.NEC ART. 370-23, ART. 370-27 (C) &ART. 422-1B9.LIGHTS AT BATH TO BE CENTERED OVER LAVS.10.LIGHT FIXTURES INSTALLED OUTSIDE SHALL COMPLY WITH 93/NEC ARTICLE 41 â–¡-4 FORDAMP LOCATION.11.IT IS ELECTRICAL CONTRACTORS RESPONSABILITY TO ENSURE THAT ALL WORK CONFORMSTO ALL GOVERNING FEDERAL AND LOCAL CODES12.COORDINATE LIGHT FIXTURES SELECTION WITH THE OWNER13.ARC-FAULT CIRCUIT INTERRUPTER14.E-3902.12 -ALL FAMILY ROOM, DINING ROOM, LIVING ROOM, PARLORS, LIBRARIES, DENS,BEDROOMS, SUNROOMS, AND SIMILAR ROOMS15.INSTALL CARBON MONOXIDE (CO) DETECTOR OUTSIDE OF EACH SEPARATE SLEEPING AREAIN THE IMMEDIATE VICINITY OF THE BEDROOMS. SINGLE STATION (CO) ALARM SHALL BELISTED AS COM PL YING WITH UL 2034 AND SHALL BE INSTALLED IN ACCORDANCE WITHTHIS CODE AND MANUFACTURER'S INSTRUCTIONS.16.INSTALL AIRTIGHT AND IC RATED RECESSED LIGHTING FIXTURES WHEN PENETRATING THEAIRFTHERMAL BARRIER AT INSULATED CEILINGS17.OUTLETS FOR RANGES AND CLOTHES DRYERS SHALL BE A 3-POLE WITH GROUND TYPE. 4WIRE, GROUNDING TYPE FLEXIBLE CORDS ARE REQUIRED FOR RANGES AND CLOTHESDRYERS. THE BONDING JUMPER SHALL NOT BE CONNECTED BETWEEN NEUTRAL TERMINALAND THE FRAME OF THE APPLIANCE.18.ALL GENERAL USE RECEPTACLES, 125-VOL T, 15 AND 20 AMPS RECEPTACLES SHALL BELISTED TAMPER RESISTANT RECEPTACLES.19.75% OF LAMPS IN PERMANENT FIXTURES OR 75% OF PERMANENT FIXTURES HAVE HIGHEFFICACY LAMPS. DOES NOT APPLY TO LOW-VOLTAGE LIGHTING.20.FUEL GAS LIGHTING SYSTEMS HAVE NO CONTINUOUS PILOT LIGHTS ALL BRANCH CIRCUITSTHAT SUPPLY 125-VOL TS, SINGLE PHASE, 15-AND 20- AMP RECEPTACLE OUTLETSINSTALLED FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS AND SIMILAR ROOMS ORAREAS SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTERINSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. ( IRC 3902.11) NECART.212-B.DATE:SCALE:NUMBER SHEETSPAGE NUMBERPROJECT No.55 of 5ELECTRIC PLANSDRAWN BY:RCJDESIGNED BY:RCJREV DESCRIPTION DATEBY AS SHOWNELECTRIC PLANSSCALE: 1" = 10'ELECTRIC LAYOUTSCALE: 1" = 10'ELECTRICAL NOTE:E3902.12 ARC-FAULTCIRCUIT-INTERUPTER PROTECTION.ALL BRANCH CIRCUITS THAT SUPPLY120-VOLT, SINGLE-PHASE, 15- AND20-AMPERE OUTLETS INSTALLED INFAMILY ROOM, DINING ROOMS, LIVINGROOMS, PARLORS, LIBRARIES, DENS,BEDROOMS, SUNROOMS,RECREATION ROOMS, CLOSETS,HALLWAYS AND SIMILAR ROOMS ORAREAS SHALL BE PROTECTED BY ACOMBINATION TYPE ARC-FAULTCIRCUIT INTERRUPTER INSTALLED TOPROVIDE PROTECTION OF THEBRANCH CIRCUIT.ELECTRICAL NOTE:RECEPTACLE OUTLETS SHALL BE LOCATEDNOT MORE THAN 20" ABOVE THECOUNTERTOP. RECEPTACLE OUTLETSASSEMBLIES INSTALLED IN COUNTERTOPSSHALL BE LISTED FOR THE APPLICATION.RECEPTACLE OUTLETS SHALL NOT VEINSTALLED IN A FACE-UP POSITION ON THEWORK SURFACES OR COUNTERTOPS.RECEPTACLE OUTLETS RENDERED NOTREADILY ACCESSIVLE BY APPLIANCESFASTENED IN PLACE, APPLIANCE GARAGES,SINKS OR RANGE TOPS AS ADDRESSED INTHE EXCEPTION TO SECTION E3901.4.1, ORAPPLIANCES OCCUPYING DEDICATEDSPACE SHALL NOT BE CONSIDERED ASTHESE REQUIRED OUTLETS.OCT 20231023-0340PLOT DATE:10/23/2023CHECKED BY:JPFONDER RESIDENCE DETACHED GARAGE ATLANTIC BEACH, FLNOTE:THE ELECTRICAL PLAN IS ONLY FORELECTRICAL IT IS THE CONTRACTORSRESPONSIBILITY TO COORDINATE IN THE FIELDWITH OTHER SUBS EXACT LOCATIONS ANDLAYOUTS OF BUILDING AND ITS COMPONENTSMAIN ELECTRIC RUN FORM MAIN PANEL TO SUBPANEL, CONTRACTOR SHALL VERIFY EXISTING PANELSCONDITION AND SIZE TO ENSURE IT CAN SUPPLYPROPOSED GARAGE PROPERLY