1600 Selva Marina Drive FIRE24-0001 PermitOWNER:ADDRESS:CITY:STATE:ZIP: ATLANTIC BEACH COUNTRY CLUB INC 1600 SELVA MARINA DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: LIFE SAFETY DESIGNS INC 3038 LENOX AVENUE JACKSONVILLE FL 32254 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172000 0010 SELVA MARINA UNIT 05 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1600 SELVA MARINA DR FIRE ALARM PHASE 2 - CLUBHOUSE FIRE ALARM $18928.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT ADMINISTRATIVE FEE 455-0000-322-1000 0 $35.00 FIRE DEPARTMENT FEE 45500002080800 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $139.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 4/18/2024 PERMIT NUMBER FIRE24-0001 ISSUED: 4/18/2024 EXPIRES: 10/15/2024 FIRE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 4/18/2024 PERMIT NUMBER FIRE24-0001 ISSUED: 4/18/2024 EXPIRES: 10/15/2024 FIRE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing Dry-In Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department - Phone: 904-247-5826 - Email: Building-Dept@coab.us Public Works/Utilities - Phone: 904-247-5834 Fire Department - Phone: 904-630-4789 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION P.O. NO. DATE JOB NO. TO ATTENTION PROJECT WE ARE SENDING YOU X SHOP DRAWINGS X SUBMITTAL DATA SAMPLES SPECIFICATIONS O&M MANUALS COPY OF LETTER CHANGE ORDER PERMIT PACKAGE THESE ARE TRANSMITTED AS CHECKED BELOW X FOR APPROVAL APPROVED AS SUBMITTED RESUBMIT COPIES FOR APPROVAL FOR YOUR USE APPROVED AS NOTED SUBMIT COPIES FOR DISTRIBUTION AS REQUESTED RETURNED FOR CORRECTIONS RETURN CORRECTED PRINTS FOR REVIEW AND COMMENT X NO. EA EA EA REMARKS COPY TO SIGNED FIRE ALARM PERMIT BUILDING DEPARTMENT April 9, 2024 2233010 1600 SELVA MARINA DR. PRODUCT DATA & CALCULATIONS SUBMITTAL PACKAGE FOR ATLANTIC BEACH COUNTRY CLUB - PHASE II - MAIN CLUBHOUSE RENOVATIONS 1 04/09/2024 CITY OF ATLANTIC BEACH BUILDING DEPARTMENT DATE DESCRIPTION ATLANTIC BEACH COUNTRY CLUB - PHASE II - MAIN CLUBHOUSE RENOVATIONS ATLANTIC BCH, FL. 32233 COPIES 1 ALL SUBMITTAL DATA PACKAGES ARE IN PDF FORMAT CITY OF ATLANTIC BEACH ELECTRICAL PERMIT FORM - FIRE ALARM - SIGNED 04/09/2024 1 FL – EFOOO878 FL CONTRACTOR I - 13235500011993 GA - LVU004677 PLACIDE DENIS, JR. PLACIDE DENIS, JR. 04/09/2024 WWW.LIFESAFETYDESIGNS.COM 3038 Lenox Avenue • Jacksonville • Florida 32254 • 904-388-1700 • Fax 904-388-1718 SHOP DRAWINGS FOR ATLANTIC BEACH COUNTRY CLUB - PHASE II - MAIN CLUBHOUSE RENOVATIONS LETTER OF TRANSMITTAL FIRE ALARM PRODUCT DATA SBUMITTAL PACKAGE 3038 LENOX AVE. • Jacksonville • Florida 32254 • 904-388-1700 • Fax 904-388-1718 FL – EFOOO878 FL CONTRACTOR I – 13235500011993 GA – LVU004677 SUBMITTAL DATA FOR: ATLANTIC BEACH COUNTRY CLUB RENOVATIONS PHASE II MAIN CLUBHOUSE 1600 SELVA MARINA DR. ATLANTIC BEACH, FLORIDA 32233 JOB No. 2233010 January 12, 2024 ELECTRICAL CONTRACTOR: E3 Electric of NE FL TABLE OF CONTENTS: I FIRE ALARM MANUFACTURERS CATALOG DATA DESCRIPTION MANUFACTURER PART# PAGE# a) FIRE ALARM CONTROL PANEL-EXISTING NOTIFIER NFW2-100 1-6 *** DATA SHEET PROVIDED FOR REFERENCE ONLY*** b) VOICE EVACUATION CNTRL PANEL-EXISTING NOTIFIER NFC-50/100 w/: 7-14 70V TRANSFORMER CONVERSION MODULE NOTIFIER NFC-XRM-70V 70V AUDIO AMPLIFIER MODULE NOTIFIER NFC-BDA-70V *** DATA SHEET PROVIDED FOR REFERENCE ONLY*** c) REMOTE POWER SUPPLY NOTIFIER HPF-PS6 15-16 d) FIRE ALARM TERMINAL CABINET SPACE AGE ELECTRONICS INC. SSU00635 17-18 e) MANUAL PULL STATION NOTIFIER NOT-BG12LX 19-20 f) SMOKE DETECTOR NOTIFIER NP-200 w/: 21-22 BASE NOTIFIER B300-6 23-25 g) DUCT SMOKE DETECTOR DUCT DETECTOR HOUSING NOTIFIER DNR 26-27 REM. CAP. DETECTOR HEAD NOTIFIER NP-200R 26-27 SAMPLING TUBE NOTIFIER DST5 26-27 h) RELAY MODULE NOTIFIER NC-100R 28-29 j) MONITOR MODULE NOTIFIER NMM-100 30-33 k) WALL MTD. WHITE SPEAKER/STROBE NOTIFIER/SYSTEM SENSOR SPSWL 34-37 l) WALL MTD. WP WHITE SPEAKER/STROBE NOTIFIER/SYSTEM SENSOR SPSCWK 38-41 m) 120VAC SURGE SUPPRESSOR DITEK DTK-120SRD 42 dn-60417:B • 10/14/08 — Page 1 of 6 FireWarden-100-2(E) Rev 2 Intelligent Addressable FACP with Built-In Communciator Addressable dn-60417:B 7101cov.jpgGeneral The Notifier FireWarden-100-2 Rev 2 (NFW2-100 Rev 2) with Version 4.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Trans- mitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the FireWarden-100-2 Rev 2 operates using a Rapid Group Polling communication proto- col technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an inci- dent and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. (Consult the wire table on page 5 for specific installation instructions.) The FireWarden-100-2 Rev 2’s quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools, the Upload/ Download software kit, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP’s keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other program- ming information. Version 4.0 firmware supports the following: ANN-bus devices, USB port, NAC circuit diagnostics, a new report has been added to the walk-test that lists untested devices, new device types added: audio telephone type code for NFV-25/50ZST (release pending), Photo Supervisory and auto-resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term “FireWarden-100-2” is used in this document to refer to both the FireWarden-100-2 and the FireWarden-100-2E FACPs (Fire Alarm Control Panels). Like- wise, “NFW2-100” refers to NFW2-100E as well. Features • Listed to UL standard 864, 9th edition. • On-board DACT. • Remote site or local USB port upload/download, using PS- Tools. • Four Style Y (Class B) or two Class A (Style Z) NAC cir- cuits. (Up to 6.0 amps total NAC power when using optional XRM-24B.) • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. • Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or FDU-80, N-ANN-80 or ACS Annunciators. • ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): –N-ANN-80(-W) Remote LCD Annunciator –N-ANN-I/O LED Driver –N-ANN-S/PG Printer Module –N-ANN-RLY Relay Module –N-ANN-LED Annunciator Module –N-ANN-RLED Annunciator Module alarms only • ACS & Terminal-mode Annunciators: –ACS Annunciators: Up to 32 ACM Series annunciators (ACM-16AT or ACM-32 series). Cannot be used if ANN- BUS devices are used. –Terminal-mode Annunciators: Up to 32 FDU-80 annuncia- tors. • EIA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. 01/12/2024 1 *** PROVIDED FOR REFERENCE ONLY *** Page 2 of 6 — dn-60417:B • 10/14/08 • Real-time clock/calendar with automatic daylight savings control. • Detector sensitivity test capability (NFPA 72 compliant). • History file with 1,000-event capacity. • Maintenance alert warns when smoke detector dust accu- mulation is excessive. • Automatic device type-code verification. • One person audible or silent walk test with walk-test log and printout. • Point trouble identification. • Waterflow (nonsilenceable) selection per monitor point. • System alarm verification selection per detector point. • PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: • SLC can be configured for NFPA Style 4, 6, or 7 operation. • SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). • SLC loop maximum length 10,000 ft. (3,000 m.). See wire table on page 5. NOTIFICATION APPLIANCE CIRCUITS (NACS): • Four onboard NACs with additional NAC capability using output control modules (NC-100). The four Class B NACs can be converted to two Class A NACs with NACKEY (included). • Silence Inhibit and Auto Silence timer options. • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. • Selectable strobe synchronization per NAC. • 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: • Autoprogram (learn mode) reduces installation time. • Custom English labels (per point) may be manually entered or selected from an internal library file. • Three Form-C relay outputs (two programmable). • 99 software zones. • Continuous fire protection during online programming at the front panel. • Program Check automatically catches common errors not linked to any zone or input point. •OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (NFW2-100 requires PS-Tools Programming software, available on VFWARDEN-CD and www.magni-fire.com). Upload/download system programming locally to the Fire- Warden-100-2(E) Rev 2 in less than one minute. • USB programming with standard Male-A to Male-B cable. User interface LED INDICATORS • AC Power (green) • Fire Alarm (red) • Supervisory (yellow) • Alarm Silenced (yellow) • System Trouble (yellow) • Maintenance/Presignal (yellow) • Disabled (yellow) • Battery Fault (yellow) • Ground Fault (yellow) KEYPAD CONTROLS • Acknowledge/Step • Alarm Silence • Drill • System Reset (lamp test) • 16-key alpha-numeric pad (similar to telephone keypad) • 4 cursor keys •Enter Product Line Information NFW2-100: FireWarden-100-2 Rev 2 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed circuit board mounted on chassis, and cabinet. 120 VAC operation. NFW2-100R: Same as FireWarden-100 Rev 2, except in a red backbox. NFW2-100E: Same as NFW2-100 Rev 2, except with 240 VAC operation. 4XTM Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. VFWARDEN-CD: Contains PS-Tools Programming software for Windows®-based PC computer (cable not included). DP-9692B: Optional dress panel for FireWarden-100-2 Rev 2. TR-CE-B: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional NFS- LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E Rev 2. PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet dn-60408 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclo- sure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS N-ANN-80(-W): LCD Annunciator is a remote LCD annuncia- tor that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -W version for white; see DN-7114.) 01/12/2024 2 *** PROVIDED FOR REFERENCE ONLY *** dn-60417:B • 10/14/08 — Page 3 of 6 N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red or black enclosure (see DN-60242). N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242). N-ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DN- 7107.) N-ANN-S/PG: Serial/Parallel Printer Gateway module pro- vides a connection for a serial or parallel printer. (See DN- 7103.) N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-7105.) ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capa- ble of providing up to 99 software zones of annunciation. Avail- able in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the FireWarden-100-2 Rev 2, see the following data sheets (document numbers) ACM-8R (DN-3558), ACS/ACM Series (DN- 0524), LDM Series (DN-0551), FDU-80 (DN-6820). COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. NP-100T: Addressable low-profile photoelectric smoke detector with thermal sensor. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate- of-rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. ND-100: Photoelectric low-flow duct smoke detector. ND-100R: Photoelectric low-flow duct smoke detector with relay option. NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the NMM-100P. NZM-100-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. NOTE: For more information on Compatible Addressable Devices for use with the FireWarden-100-2 Rev 2, see the following data sheets (document numbers): N100-ISO (DN-6994), NP-100 series (DN-6995), NI-100 (DN-6996), NH-100 series (DN-6997), ND-100 series (DN-7006), NMM-100/NMM-100P/NDM-100/NZM-100 (DN- 6999), NC-100/NC-100R (DN-7000), NOT-BG12LX (DN-7001), and NZM-100-6 (DN-60150). 01/12/2024 3 *** PROVIDED FOR REFERENCE ONLY *** Page 4 of 6 — dn-60417:B • 10/14/08 60417sys.wmf01/12/2024 4 *** PROVIDED FOR REFERENCE ONLY *** dn-60417:B • 10/14/08 — Page 5 of 6 Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm²) and no larger than 12 AWG (3.1 mm²). The wire size depends on the length of the SLC circuit. Use the follow- ing table to determine the specific wiring requirements for the SLC. SLC Wire Requirements Distance in Feet (m)Wire Size Wire Type Twisted-pair, unshielded 10,000 feet (3,048 m)12 AWG (3.31 mm2) Non-Plenum (FPLR): Genesis 4315, Belden 5020UL Plenum (FPLP): Genesis 4515, Belden 6020UL Twisted-pair, unshielded 8,000 feet (2,438 m)14 AWG (2.08 mm2) Non-Plenum (FPLR): Genesis 4313, Belden 5120UL Plenum (FPLP): Genesis 4513, Belden 6120UL Twisted-pair, unshielded 4,875 feet (1,486 m)16 AWG (1.31 mm2) Non-Plenum (FPLR): Genesis 4311, Belden 5220UL Plenum (FPLP): Genesis 4511, Belden 6220UL Twisted-pair, unshielded 3,225 feet (983 m)18 AWG (0.821 mm2) Non-Plenum (FPLR): Genesis 4306, Belden 5320UL Plenum (FPLP): Genesis 4506, Belden 6320UL FireWarden-100-2 Wire Requirements 01/12/2024 5 *** PROVIDED FOR REFERENCE ONLY *** Page 6 of 6 — dn-60417:B • 10/14/08 System Capacity • Intelligent Signalling Line Circuits.......................................1 • Addressable device capacity..........................................198 • Programmable software zones.........................................99 • ACS Annunciators ............................................................32 • ANN-bus devices................................................................8 Electrical Specifications AC Power: FireWarden-100-2 Rev 2: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2 Rev 2(E): 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm²) with 600 V insulation. Battery: Two 12 V 18AH lead-acid batteries. Battery charger capacity: 7 – 18 AH. FireWarden-100-2 Rev 2 cabinet holds maximum of two 18 AH batteries. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) or one Style Z (Class A) for a total of four Style Y (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to panel documen- tation and Notifier Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Power (24 VDC Nominal): Jumper selectable (JP4) for conversion to resettable power output. Up to 0.3 amps total DC current available from each output. Power-limited. Four-Wire Resettable Special Application Smoke Detector Power (24 VDC nominal): Up to 0.3 amps for powering four- wire smoke detectors. Power-limited. Refer to the Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 40 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR-CE-B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00” (50.80 cm.) high x 22.5” (57.15 cm.) wide x 8.5” (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. NFPA Standards The FireWarden-100-2 Rev 2 complies with the following NFPA 72 Fire Alarm Systems requirements: – LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). –AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). – REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) –PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). – CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). –OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic FireWar- den-100-2 Rev 2 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL: S635 •FM approved •CSFM: 7165-0028:235 •MEA: 120-06-E, Volume 2 FireWarden® and Notifier® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com SYSTEM SPECIFICATIONS 01/12/2024 6 *** PROVIDED FOR REFERENCE ONLY *** DN-60772:A1 • 7/15/13 — Page 1 of 8 First Command NFC-50/100(E) Voice Evacuation & Emergency Communications System DN-60772:A1 General Notifier’s First Command NFC-50/100 and NFC-50/100E aremultipurpose emergency voice evacuation panels for fire appli- cations, mass notification applications, or both. The First Com- mand delivers 50 or 100 watts of audio power for distribution to up to eight speaker circuits (i.e. zones). The NFC-50/100(E) comes standard with a single speaker circuit and a built-in 50 watt, 25V amplifier. A secondary 50 watt amplifier (NFC-BDA- 25/70V) can be added for single speaker circuit backup or to increase system capacity to two speaker circuits and an addi- tional 50 watts of audio power. An optional NFC-CE6 module added to the NFC-50/100(E) will upgrade the system to a max-imum of eight speaker circuit outputs. All speaker output cir- cuits can be wired in either Style Y (Class B) or Style Z (Class A) configuration. The NFC-50/100(E) has fourteen field pro-grammable messages (up to 60 seconds each), built-in field configurable pre- and post-announce tone generators and a fully supervised Notification Appliance Circuit (NAC) with 2.0 amps of synchronized NAC power. The NFC-50/100(E) includes three built-in Form-C relay contacts, (AC power, trou- ble and MNS active) a NAC follower and 500mA special appli- cation power. A built-in power supply delivers operationalpower and on board battery charger supports charging up to 26AH batteries (NFC cabinet holds up to 18AH batteries). For fire protection applications, the NFC-50/100(E) is anadjunct (slave) to most UL listed FACPs or as a stand-alone unit for non-fire applications. For seamless integration between fire and mass notification, the NFC-50/100(E) can be activated by the NFW2-100(Rev 3) and NFW-50 when con- nected to the ACS/ANN serial communication bus. Activation of the NFC-50/100(E) via other FACP's uses the eight on board Command Input Circuits (CMD's). Two of the eight CMDcircuits (CMD 1 & CMD 2) can be individually field pro- grammed for activation by an FACP Notification Appliance Cir- cuit reverse polarity and all eight can be activated by a contactclosure. In addition, the NFC-50/100(E) can be activated from a building's Private Branch Exchange (PBX) with the integral night ring feature. All NFC-50/100(E) programming is done by using a simple, built-in programming utility accessed from any laptop. For added flexibility, the NFC-50/100(E) supports both 25V and 70V speaker output operation. By adding a 70V transformerconversion module (NFC-XRM-70V) or an additional 70 volt secondary amplifier (NFC-BDA-25/70V) the system supports 70 volt speaker devices. The NFC-50/100(E) can expand in order to accommodate larger or more complex installations. To add more control and increase system capacity, any combination of up to eight exter- nal remote consoles (including the NFC-LOC, NFC-RPU, and NFC-RM) and up to eight distributed audio amplifiers (includ- ing the NFC-50DA(E) and NFC-125-DA(E) can be connected on the external data bus and audio riser data bus to create afully integrated command center. A fully loaded system sup- ports up to 1100 watts of total audio power and up to 24 speaker circuit outputs. TYPICAL APPLICATIONS Features • UL Listed to UL 2572 Communication (Control Units MassNotification Systems) and UL 864 (emergency voice evacu- ation for fire). • Modular design for system flexibility and easy expansion. • Removable terminal blocks. • 50 watts of 25V audio power (expandable to 100 watts)RMS. • 2 amp Notification Appliance Circuit (NAC) output, sync generator, or follower for System Sensor, Wheelock or Gen- tex protocols. • Optional 70V transformer available for the primary amplifier. (Note that speaker wiring continues to be supervised in standby, alarm and when background music is playing with this optional transformer installed). • Eight Command Input Circuits to activate messages 1 to 8: –CMD1 and CMD2 are field selectable to be activated from12 or 24 VDC Notification Appliance Circuits (reverse polarity) or contact closures. –CMD3-CMD8 are activated by contact closures. • Speaker Circuits. –Single Style Y (Class B) or Style Z (Class A) speaker Cir-cuit. • Schools • Nursing Homes • Factories • Theaters • Military facilities • Restaurants • Auditoriums • Places of Worship • Office Buildings 01/12/2024 7 *** PROVIDED FOR REFERENCE ONLY *** Page 2 of 8 — DN-60772:A1 • 7/15/13 –Two Style Y (Class B) or Style Z (Class A) speaker cir- cuits (with optional NFC-BDA-25/70V Audio Amplifier installed). –Eight Style Y (Class B) or Style Z (Class A) speaker cir- cuits (with optional NFC-BDA-25/70V and NFC-CE6installed). • NFC-50/100(E) can be controlled by an FACP via the ANN/ACS (EIA-485) link of the NFW2-100 (Rev 3). • Integral supervised microphone. • Microphone time-out feature which reverts back to pre- recorded message if emergency page exceeds the pro- grammed time. • 14 recorded messages. • Field-selectable message and custom message recording capability using the local microphone, a USB port, or anexternal audio input. • External Audio Input can be used for background music. • Up to 60 second message duration for all messages. • Integral tone generators field selectable for multiple tone types. • Powered by integral AC power supply or batteries during AC fail. • Programmable delay of immediate, 2 hours or 6 hours reporting of AC Loss. • Piezo sounder for local trouble. • 100 event history log. • Three Form-C relays: –AC Power Loss Relay - TB1. –System Trouble Relay - TB2. –MNS Active - TB3. • 500mA (0.5A) Special Application (auxiliary power) output for addressable modules when interfaced with compatible addressable FACPs and End-of-Line power supervision relays. • System Status LEDs (refer to “Controls and Indicators” on product manual LS10001-000NF-E). • Integral Dress Panel. • Optional TR-CE-B semi-flush trim ring. • Any combination of up to eight (8) external remote con- soles: –Optional NFC-RM Remote Microphone (includes cabi- net). See DN-60778. –Optional NFC-RPU Remote Page Unit (includes cabinet). See DN-60775. –Optional NFC-LOC Local operator console (includes cab- inet). See DN-60777. • Any combination of up to eight (8) distributed audio amplifi- ers: –Optional NFC-50DA(E) distributed amplifier, 50 watts. See DN-60776. –Optional NFC-125DA(E) distributed amplifier, 125 watts. See DN-60776. Optional Internal Expansion Modules NFC-CE6: Circuit Expander Module provides connections for up to six Style Z (Class A) or Style Y (Class B) speaker cir- cuits. Circuits are configured through the web-based program- ming utility. NFC-BDA-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total NFC-50/100 power output to 100 watts or can also be used as a backup amplifier. NFC-BDA-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total NFC-50/100 power output to 100 watts or can also be used as a backup amplifier. NFC-XRM-70V: 70V Transformer Conversion Module. Con- verts the NFC-50/100(E) primary amplifier to a 70V output. This transformer mounts directly to the NFC-50/100(E) main control board by two metal brackets. 01/12/2024 8 *** PROVIDED FOR REFERENCE ONLY *** DN-60772:A1 • 7/15/13 — Page 3 of 8 horns/strobes Speaker Circuits TB20 & TB21 NAC Circuit TB19 Internal options NFC-CE6 circuit expander NFC-BDA-25/70V optionalamplifier NFC-FFT firefighter telephone remote consoles NFC-LOC local operator console NFC-RPU remote paging unit NFC-RM remote microphone TB4 TB12 TB22distributed audioexternal battery charger - J7 NFC-50DA 50W remote amplifier NFC-125DA 125W remote amplifier CHG-120 charger CHG-75 charger NFC-50/100(E) FirstCommand (Possible Configurations) 01/12/2024 9 *** PROVIDED FOR REFERENCE ONLY *** Page 4 of 8 — DN-60772:A1 • 7/15/13 Control and Indicators PUSH BUTTON CONTROLS LED Status Indicators (visible with door closed) LED Indicators (visible with door and dress panel open) • Speaker Volume Control Fault (yellow). • Option Card Fault (yellow). • Amplifier Over Current Fault (yellow). Product Line Information NFC-50/100: (Primary Operating Console) 50 Watt, 25V single speaker zone emergency voice evacuation system, integral microphone, built in tone generator and 14 recordable mes- sages. NFC-50/100E: Export version (Primary Operating Console) 50 Watt, 25V single speaker zone emergency voice evacuation system, integral microphone, built in tone generator and 14recordable messages. (240 VAC, 50Hz). NFC-CE6: Speaker Circuit/Zone Expander Module. NFC-BDA-25V: 25V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total NFC-50/100 power output to 100 watts or can also be used as a backup amplifier. NFC-BDA-70V: 70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total NFC-50/100 poweroutput to 100 watts or can also be used as a backup amplifier. NFC-XRM-70V: 70V Transformer Conversion Module. Con- verts the NFC-50/100(E) primary amplifier to a 70V output. This transformer mounts directly to the NFC-50/100(E) main control board by two metal brackets. NFC-LOC: Local Operator Console (Complete user interface), Please refer to the data sheet DN-60777 for more information. NFC-RPU: Remote Page Unit Hand held microphone, 14 mes- sage buttons. Please refer to the data sheet DN-60775 for more information. NFC-RM: Remote Microphone only. Please refer to the data sheet DN-60778 for more information. NFC-50DA: Distributed (Remote) Audio Amplifier, 50 watts. Please refer to the data sheet DN-60776 for more information. NFC-50DAE: Export version. Distributed (Remote) Audio Amplifier, 50 watts. (240 VAC, 50Hz). Please refer to the data sheet DN-60776 for more information. • All Call • Message Select 1-14 • MNS Control • Diagnostic Select • System Control • Trouble Silence • Speaker Select 1-24 • Console Lamp Test Fire System Active (green)LOC/RPU/RM 1-8 Active (green) MNS Control (green) Main Console Fault (yellow) System Control (green) AC Power (green) System in Use (green) Ground Fault (yellow) Speaker Zone 1-24 Active (green)Charger Fault (yellow) Speaker Zone 1-24 Fault (yellow)Battery Fault (yellow) OK to Page (green) Data Bus Fault (yellow) Microphone Trouble (yellow)NAC Fault (yellow) Message 1-8 Active (red) NAC Active (green) Message 1-8 Fault (yellow) System Trouble (yellow) Remote Amplifier 1-8 Fault (yellow)Audio Riser Fault (yellow) LOC/RPU/RM 1-8 Fault (yellow) 01/12/2024 10 *** PROVIDED FOR REFERENCE ONLY *** DN-60772:A1 • 7/15/13 — Page 5 of 8 NFC-125DA: Distributed (Remote) Audio Amplifier, 125 watts. Please refer to the data sheet DN-60776 for more information. NFC-125DAE: Export version. Distributed (Remote) Audio Amplifier, 125 watts. (240 VAC, 50Hz). Please refer to the data sheet DN-60776 for more information. NFC-CE4: Distributed Audio Speaker Circuit/Zone expander module. NFC-FFT: Fire Fighter Telephone System. Please refer to the data sheet DN-60779 for more information. N-FPJ: Remote Phone Jack. FHS-F: Fire Fighters Remote Handset. FHSC-R: Fire Fighters Handset Cabinet Recessed. FHSC-S: Fire Fighters Handset Cabinet Surface Mount TR-CE-B: Optional Trim Ring. THUMBLTCH: Optional Thumb Latch. (Non UL-Listed). CHG-75: 25 to 75 ampere-hours (AH) External Battery Charger. CHG-120: 25-120 ampere-hours (AH) External Battery Charger. ECC-MICROPHONE: Replacement Microphone only. BAT-1270: Battery,12 volt,7.0 AH (Two required). BAT-12120: Battery,12 volt,12.0 AH (Two required). BAT-12180: Battery,12 volt, 18.0 AH (Two required). BAT-12260: Battery, 12 volt, 26.0 AH (Two required). BB-26: Battery cabinet mounts up to two 26 AH batteries. Wiring Requirements See product manual, part number LS10001-001NF-E for detailed wiring requirements. Total System Capacity: (NFC-50/100(E) only) • Total Built-in Audio Power: 50 Watts. • Total Expandable Audio Power: 100 Watts. • Total Built-in Speaker Circuits: 2. • Total Expandable Speaker Circuits: 8. • Audio Message Max Time Duration: 60 seconds. • External Audio Input: 1. Total System Capacity: (Fully Loaded System) • Total Distributed Audio Power: 1100 Watts. • Total Speaker Circuits Per System: 24. • Total Remote Consoles Supported: 8. • Total Distributed Audio Amplifiers Supported: 8. Electrical Specifications PRIMARY (AC) POWER (TB15) NFC-50/100: 120 VAC, 60 Hz, 3.5 amps. NFC-50/100E: 240 VAC, 50 Hz, 2.0 amps. Wire size: minimum #14 AWG (2.00mm2) with 600 V insulation. SECONDARY POWER (BATTERY) CHARGING CIRCUIT (J7) • Supports lead-acid batteries only. • Float charge voltage at 27.3V • Maximum charge current: 1.0 Amp • Maximum battery charge capability: 2.8 Amps, 26AH (NFC cabinet holds max. 18AH battery). • Minimum Battery size:12 Amp Hour. AC LOSS RELAY CONTACT RATING (TB3) • 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). FORM C - TROUBLE RELAY CONTACT RATING (TB2) • 2.0 amps @ 30 VDC (resistive), 0.5 amp @ 30 VAC (resistive). MNS ACTIVE RELAY CONTACT RATING (TB1) • 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). NOTIFICATION APPLIANCE CIRCUIT (NAC) OUTPUT RATING (TB19) • One (1) Style Y (Class B) or Style Z (Class A) circuit. • Power-limited circuitry, (Class 2) supervised. • Nominal operating voltage: 24 VDC. • Maximum signaling current for special application power: 2.0A. • Maximum signaling current for regulated power: 200mA. • Maximum wiring impedance: 1Ω. • Current limit: fuse-less, electronic, power-limited. • End-Of-Line Resistor: 4.7 KΩ, ½ watt, (P/N 71252) required for Style Y (Class B) operation. Refer to the Device Compatibility Document 15378 for listed compatible devices. NAC FOLLOWER OUTPUT REMOTE SYNC (TB18) • Connections for FACP NAC synchronization trigger signal. • Output terminals: pass-through to other system compo-nents. • Trigger input voltage: 9 to 32 VDC, 24 VDC rated. • Input current draw in Alarm condition: 10 mA at rated volt-age. SPECIAL APPLICATION POWER (AUX. POWER) (TB17) • 500 mA @ 24 VDC. • Used for powering addressable modules and associated End-of-Line power supervision relays. Power-limited circuitry. Refer to the Device Compatibility Docu- ment 15378 for a list of compatible devices. SPEAKER VOLUME CONTROL OVERRIDE (TB23) • Style Y (Class B) or Style Z (Class A) circuit. • Special application power. • Power-limited circuitry, supervised. • Nominal operating voltage: 24 VDC. • Maximum signaling current: 0.25 amps. • Current limit: fuse-less, electronic, power-limited. • End-Of-Line Resistor: 4.7 KΩ, ½ watt, (P/N 71252) required for Style Y (Class B) operation. Speaker Circuits • Primary Speaker Circuit (TB20) • Secondary Speaker Circuit (TB21) (with optional amplifier only). –Circuit can be wired Style Y (Class B) or Style Z (Class A). –Power-limited circuitry. –Normal Operating Voltage: 25 VRMS @ 2 amps max and maximum Load Impedance of 12.5Ω (70V @ 700 mA max. with maximum load Impedance of 100Ω operationpossible by plugging optional NFC-XRM-70V conversion transformer into J12 of the main control board). 01/12/2024 11 *** PROVIDED FOR REFERENCE ONLY *** Page 6 of 8 — DN-60772:A1 • 7/15/13 –Output Power: 50 watts (10 watts when background music is employed). –Frequency Range: 400Hz - 4,000Hz. –Maximum total capacitance for each speaker circuit: 250 uF. –End-of-Line Resistor required for Style Y circuit: 15 KΩ, 1 watt (P/N: ELR-15K). Command Input Circuits (alarm polari- ties shown) CMD1 - TB4 Terminals 3(+) & 4(-) are input terminals and Ter- minals 1(-) and 2(+) are output terminals which provide feed through of the NAC circuits to NAC devices down stream. CMD2 - TB5 Terminals 3(+) & 4(-) are input terminals and Ter- minals 1(-) and 2(+) are output terminals which provide feedthrough of the NAC circuits to NAC devices downstream. CMD3 - TB6 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD4 - TB6 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. CMD5 - TB7 Terminals 1(+) & 2(-) are input terminals for con- tact closure only. CMD6 - TB7 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. CMD7 - TB8 Terminals 1(+) & 2(-) are input terminals for con-tact closure only. CMD8 - TB8 Terminals 3(+) & 4(-) are input terminals for con- tact closure only. • Power-limited and supervised circuitry. • Normal Operating Voltage Range: 10.5 VDC - 29 VDC;(Maximum Voltage: 29 VDC). • NAC Reverse Polarity Current (requires End-of-Line Resis- tor from NAC): 1.6 mA maximum. • Contact Closure Operation Current (requires 4.7KΩ, ½ watt End-of-Line Resistor P/N 27072): 6.6 mA maximum. • Maximum Wiring Impedance CMD1 - CMD8 (Contact Clo- sure Operation): 200Ω. NOTE: When the system is programmed for Mass Notification, CMD1and CMD2 will be programmed for Reverse Polarity only. See manual P/N LS10001-001NF-E for more details. MAXIMUM INPUT IMPEDANCE: • CMD1 & CMD2 (Reverse Polarity Operation): 20KΩ. • CMD1 - CMD8 (Contact Closure Operation): 4.75KΩ. NIGHT RING INPUT - TB16, TERMINALS 1 (+) & 2 (-) • Contact closure input. • Isolated, non-supervised. • Operation current: 3.8 mA, maximum. • Maximum wiring impedance: 30KΩ. • Minimum isolation withstand voltage: 1500 VRMS. EXTERNAL OPERATOR INTERFACE POWER OUTPUT (TB24) • Non-resettable power for external operator interface com- ponents. • Power-limited circuitry, non-supervised. • Nominal operating voltage: 24 VDC. • Maximum output current: 0.80 amps. • Current limit: fuse-less, electronic, power-limited circuit. EXTERNAL DATA BUS (EIA-485) (TB12) • Data connections for external operator interface components. • Redundant transceiver circuitry for Class A operability. • Power-limited circuitry, supervised. • Maximum wiring impedance: 13.2Ω. FACP DATA BUS (EIA-485) (TB13) • Dedicated connection to FACP serial bus. • Output terminals: pass-through to other system components. • Isolated, supervised. • Minimum isolation withstand voltage: 1500 VRMS. • Maximum wiring impedance: 40Ω (ANN-BUS), 26Ω (ACS-BUS). • External Audio Riser (TB22). • Style Y (Class B) or Style Z (Class A) audio connections to external operator interface components. • Power-limited circuitry, supervised. • Audio signal level: 3.85 V, maximum. • Frequency range: 400 Hz - 4 KHz RMS. • Frequency range (NFC-50/125DA): 800Hz - 2KHz RMS. EXTERNAL AUDIO INPUT (TB5) • Input Impedance: 8.5KΩ nominal @1KHz. • Input Voltage: 700 mV rms maximum. • Input Current: 0.1 mA maximum @ 700 mV. NOTE: Some laptops/personal computers only provide an audio output for headphones. It may be necessary to adjust the head- phone output level for proper recording of voice messages. NFC-CE6 Circuit Expander Module Specifications • Power-limited circuitry. • Up to six (6) circuits on the NFC-CE6 can be wired as Style Y (Class B) or Style Z (Class A). • Normal Operating Voltage for Speaker Circuits: 25 V@ 2.0 amps max. (Maximum Load Impedance of 12.5Ω). • 70.0 V @ 700 mA max. with maximum Load Impedance of 100Ω operation possible for the primary circuit by pluggingin an optional NFC-XRM-70V conversion transformer into J12 of the main control board. The same operation is possi- ble for the optional 50W amplifier by selecting the NFC- BDA-70V model. • Speaker circuit wiring is supervised during standby, back-ground music, and alarm. • Output Power: 50 watts total; Frequency Range: 400Hz -4,000Hz. • Maximum total capacitance: 250 µF. (Note that the total capacitance for the speaker outputs must not exceed the maximum of 250 µF). • End-of-Line Resistor required for Style Y (Class B) speaker circuit: 15 KΩ, 1 watt (P/N: ELR-15K)TB13 on the main control board: ACS/ANN (EIA-485) electrically isolated link to FACP provides programmed speaker control. Cabinet Specifications Backbox: 19.0"(48.26 cm) high x 16.65"(42.29 cm) wide x 5.20"(13.23 cm) deep. Door: 19.26” (48.92 cm) high x 16.82”(42.73 cm) wide x 0.12”(0.30 cm) deep. Trim Ring (TR-CE-B): 22.00” (55.88 cm) high x 19.65” (49.91cm) wide. Shipping Specifications Base Unit Weight: 27.85 lbs (12.63 kg). 01/12/2024 12 *** PROVIDED FOR REFERENCE ONLY *** DN-60772:A1 • 7/15/13 — Page 7 of 8 Temperature and Humidity ranges This system meets NFPA requirements for operation at 0-49º C/32-120º F and at a relative humidity 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperatureranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-27º C/60-80º F. Agency Listings and Approvals The listings and approvals below apply to the basic NFC-50/ 100(E) control panel. In some cases, certain modules may not be listed by certain approval agencies or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed S635. • Compliant with UFC 4-021-01. Standards and Codes The NFC-50/100(E) complies with the following UL Standards and with NFPA 72 Fire Alarm system requirements. • UL 864. • UL 2572. 01/12/2024 13 *** PROVIDED FOR REFERENCE ONLY *** Page 8 of 8 — DN-60772:A1 • 7/15/13 Notifier® is a registered trademark of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. 01/12/2024 14 *** PROVIDED FOR REFERENCE ONLY *** DN-61092:D • 8/15/2023 — Page 1 of 2 HPF-PS6/HPF-PS10 Series 6/10 Amp, 24 Volt Power Supplies General The HPF-PS Series is a remote power supply line from Honeywell and is a direct replacement for the PSE and FCPS Series. The HPF-PS6(B)(E) is a 6 amp and the HPF-PS10(B)(E) is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a stand- alone power supply. The HPF-PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B orClass A (requires the ZNAC-PS option card) with multiple sync pro- tocol options. The HPF-PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door hold- ers, and other fire alarm system peripherals. The HPF-PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. The HPF-PS6E and HPF-PS10E are models rated for 240V operation. Features • Up to five (6 amp model) or seven (10 amp model) independently- configurable, power-limited output circuits for: –Class B and/or Class A NACs –Class B and/or Class A resettable or non-resettable 24V auxil- iary power –door holder power • Converts from Class B to Class A wiring without losing any out- puts using the ZNAC-PS converter card (sold separately) • Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Configurable for ANSI® Temporal 3 or Temporal 4 coded output • UL-Listed NAC synchronization using System Sensor®, Whee- lock®, Gentex®, or AMSECO® appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) or three (10 amp model) fully-isolated input/ control circuits which can be programmed to any output • Two Form C normally-closed trouble relays for AC Trouble and General Trouble, Ground Fault relay available on Canadian mod-els only • 6 or 10 amp full load output, respectively, with 3 A maximum/cir-cuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history modes for diagnostic support • Wide range end-of-line supervision value (normal: 2K-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra soft- ware required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applicationsrequiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire • Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit • Optional devices include addressable control, monitor, and relay modules and power-supervision relay (EOLR-1) Standards and Codes The HPF-PS Series comply with the following standards: •NFPA 72 National Fire Alarm Code •UL 864 Standard for Control Units for Fire Alarm Systems (NACexpander mode), 10th Edition •UL 1481 Power Supplies for Fire Alarm Systems •IBC 2009 (when using SEISKIT-MULTI-1) •CBC 2007 (when using SEISKIT-MULTI-1) Agency Listings and Approvals These listings and approvals apply to the modules specified in thisdocument. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S24562 (HPF-PS/E Series), S635, S674 (PSE Series, discontinued) •ULC Listed: S24562 (HPF-PS Series), S635 (PSE-6C/PSE-10C discontinued) •CSFM Approved: 7315-1637:0505 (HPF-PS Series), 7315-0028:0513 (PSE Series, discontinued) •FDNY COA: 2022-TMCOAP-002231-AMND (HPF-PS Series), 2021-TMCOAP-001761-CERT (PSE Series, discontinued) •FM Approved 01/12/2024 15 NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com NOTIFIER® and System Sensor® are registered trademarks of Honeywell International, Inc. Wheelock® is a registered trademark of Cooper Tech- nologies Company. Gentex® is a registered trademark of Gentex Corpora- tion. AMSECO® is a registered trademark of Potter Electric Signal Company, LLC. ANSI® is a registered trademark of the American National Standards Institute, Inc. ©2023 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of Origin: USA SPECIFICATIONS Primary (AC) Power: •HPF-PS6(B): 120 VAC, 50/60 Hz, 5.0A maximum •HPF-PS10(B): 120VAC, 50/60 Hz, 6.2 A maximum •HPF-PS6E: 240 VAC, 50/60 Hz, 2.7A maximum •HPF-PS10E: 240 VAC, 50/60 Hz, 3.5A maximum •Wire Size: #12-14 AWG with 600 V insulation Command Input Circuit: •Trigger Input Voltage: 9 to 32 VDC •Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V) Trouble Contact Rating: 4 A at 24 VDC Output Circuits: • 24 VDC filtered, regulated • HPF-PS6(B): TB8-TB9 – 1A Regulated, 3A special applications;TB10-TB12 – 0.3A Regulated, 3A special applications • HPF-PS10(B): TB8-TB11 – 1.5A Regulated, 3A special applica- tions; TB12-TB14 – 0.3A Regulated, 3A special applications • 6.0 A (HPF-PS6) or 10.0 A (HPF-PS10) maximum total continu- ous current for all outputs Secondary Power (Battery) Charging Circuit: • Supports lead-acid batteries only • Float-charge voltage: 27.6 VDC • Maximum current charge: 1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) Physical: •Dimensions: 20.0”H x 14.5”W x 3.5”D (cm: 50.8H x 36.83W x8.9D) •Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two18 AH batteries is 39 pounds (17.7 kg) Ordering Information HPF-PS6: 6.0 A, 120 VAC remote charger power supply in a lock- able, metal enclosure, red HPF-PS6B: 6.0 A, 120 VAC remote charger power supply in a lock-able, metal enclosure, black HPF-PS6E: 6.0 A, 240 VAC remote charger power supply in a lock- able, metal enclosure, red HPF-PS10: 10.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red HPF-PS10B: 10.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, black HPF-PS10E: 10.0 A, 240 VAC remote charger power supply in a lockable, metal enclosure, red ZNAC-PS: Optional Class A output converter module 50152254-001: Hardware kit for Canadian applications 17045: Alternate NOTIFIER lock set FCM-1: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notifica- tion appliances. FRM-1: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch FMM-1: Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Class B or Class A IDC. FDM-1: Dual Monitor Module. Same as FMM-1 except it providestwo inputs for Class B wiring only FDRM-1: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only. XP6-C: Six-circuit supervised control module XP6-R: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required, see BAT Series data sheet DN-6933). BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack BAT-12330: Battery, 12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the HPF-PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. 01/12/2024 16 01/12/2024 17 01/12/2024 18 DN-7001:D • 4/13/2012 — Page 1 of 2 NOT-BG12LX Addressable Manual Pull Station Intelligent/Addressable Devices DN-7001:D • A1-380 The NOT-BG12LX Addressable Manual Pull Station 6643cov1.jpgGeneral The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm² wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications •Shipping Weight: 9.6 oz. (272.15 g) •Normal operating voltage: 24 VDC. •Maximum SLC loop voltage: 28.0 VDC. •Maximum SLC standby current: 375 A. •Maximum SLC alarm current: 5 mA. •Temperature Range: 32°F to 120°F (0°C to 49°C) •Relative Humidity: 10% to 93% (noncondensing) •For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word “ACTI- VATED” (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 99 on NFW2-100/NFW2-100C, 1 – 50 for NFW-50/NFW- 50C). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed 01/12/2024 19 Page 2 of 2 — DN-7001:D • 4/13/2012 NOTIFIER® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. •UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). •MEA: 67-02-E Vol. IV. •CSFM: 7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. 01/12/2024 20 DN-60979:A • 3/29/18 — Page 1 of 3 NP-200 Series Addressable Photoelectric Detectors Addressable Devices DN-60979:A NP-200 in B300-6 Base General The NOTIFIER NP-200 Series intelligent plug-in smoke detectorsare designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER’s FireWarden Series Addressable Fire Alarm Control Panels, the NP-200 Series point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage.Two LEDs on each sensor light to provide a local, visible sensor indi- cation. Dual electronic thermistors add 135°F (57°C) fixed tempera- ture thermal sensing on the NP-200T. The NP-200R is a remote testcapable detector for use with DNR Series duct detector housings. Features SLC LOOP • Two-wire loop connection. • Unit uses base for wiring. ADDRESSING • Addressable by device. • Rotary, decimal addressing: Please refer to the FireWarden panel manuals for device capacity. ARCHITECTURE • New modern profile for improved aesthetics. • Unique single-source design to respond quickly and dependably to a broad range of fires. • Integral communications and built-in type identification. • Built-in tamper-resistant feature. • Removable cover and insect-resistant screen for simple field cleaning. OPERATION • Designed to meet UL 268 7th Edition. • Factory preset at 1.5% nominal sensitivity for panel alarm thresh-old level. • Visible LED “blinks” when the unit is addressed (communicatingwith the fire panel) and latches on in alarm. • Low standby current. MECHANICALS • Sealed against back pressure. • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS • Remote LED output connection, RA100Z. Installation NP-200 series plug-in detectors use a detachable mounting base tosimplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class B) wiring. NP-200R mounts in a DNR/DNRW duct detector housing. Operation Each NP-200 Series detector uses one possible addresses on the FireWarden Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an FireWarden Series addressable fire alarm control panel. The results of the sensitivity test can be printed off the Fire-Warden Series for record keeping. Specification Voltage range: 15 – 32 VDC (peak). Standby current: 200 μA @ 24 VDC. Max current: 4.5 mA @ 24 VDC (latched “ON”). Air velocity: 4,000 ft./min. (20 m/sec.) maximum. Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter. –B300-6: 6.1" (15.6 cm) diameter. –B501: 4" (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). Operating temperature range: • NP-200: 0°C to 50°C (32°F to 122°F); • NP-200T: 0°C to 38°C (32°F to 100°F). • NP-200R: installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). 01/12/2024 21 DN-60979:A • 3/29/18 — Page 2 of 3 Relative humidity: 10%-93%, non-condensing. Listings Listings and approvals below apply to the NP200 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listed: S911 • CSFM: 7272-0028:0503 • FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: “IV” suffix indicates FlashScan® and CLIP device. NP-200: White, Addressable photoelectric detector; B300-6 base included. FlashScan only. NP-200-IV: Ivory, Addressable photoelectric detector; B300-6 base included. NP-200T: White, Same as NP-200 but with thermal element; B300-6 base included. FlashScan only. NP-200T-IV: Ivory, Same as NP-200 but with thermal element; B300-6 base included. NP-200R: White, Remote test capable addressable photoelectricdetector for use with DNR(A)/DNRW. FlashScan only. NP-200R-IV: Ivory, Remote test capable addressable photoelectric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6” base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300-6-IS: White, 6” base isolator. (CSFM: 7300-1653:0109 Pend- ing) B300-6-IV: Ivory,6” base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6” standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4” standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-BL: Black, 4” standard European flangeless mounting base.UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-IV: Ivory color, 4” standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224BI-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) B224BI-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224BIA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone.Uses FlashScan protocol. . (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmablesounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producingsound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producingsound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet theNFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmablesounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base. TR300-IV: Ivory, replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. 01/12/2024 22 DN-60054:K • 7/18/2018 — Page 1 of 3 B300-6 Standard 6” Base (White) B200S-WH Sounder Base (White) B501-WHITE Flangeless 4” Base (White)B501-BL Flangeless4” Base (Black) Intelligent Bases Standard, Relay, Isolator, Sounder, and Low-Frequency Sounder Bases General To meet local code and application requirements, NOTIFIER® offers standard 4" and 6" bases, as well as, specialty base designs includ- ing relay, isolator, sounder and low frequency sounder options for the new 900 Series of addressable detectors as well as previous generations. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals identified with a (+ and –). The 4" base offers a compact design while the 6" base provides compatibility with a wider range of junction boxes. The specialty bases support application driven requirements. These bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation. Relay bases provide one form-C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60-100 milliseconds, while the activation time for the long delay is 6-10 seconds. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases allow the Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remain- der of the circuit and automatically restores when the fault is cor- rected. Sounder and low frequency sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibil- ity in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent. Studies show that a lower frequency, cen- tered around 520 Hz, is the most ideal to wake sleeping occupants, even those with mild to severe hearing loss. The B200SR sounder and -LF sounder bases (B200SR-WH/ B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501BH Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal 3 or Continuous) through a jumper. The B200S sounder and -LF sounder bases (B200S-WH/B200S-IV/ B200S-LF-WH/B200S-LF-IV) adopt the same address as the detec- tor, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder — or a group of sounders — to activate. The command set from the FACP can be tailored to multiple event-driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal 4, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal — along with other System Sensor AV appliances — when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. Specifications NOTE: Specifications applies to all model variants “A”, “-BL”, “-LF”, “-IV”, -WH, -WHITE. See Product Line Information for detailed model descrip- tion. Diameter • B501-WHITE: 4" (10.16 cm) diameter. • B300-6: 6.1" (15.49 cm) diameter. • B224BI, B224RB: 6.2" (15.748 cm) diameter. • B200S, B200SR, B200SCOA: 6.875" (17.46 cm) diameter. Wire gauge: • B224BI, B224RB: 14 to 24 AWG. •B300-6, B210LP, B501, B200S, B200SR, B200SCOA: 12 to 24 AWG Temperature range: • B224BI, B224RB, B200S, B200SR, B200SCOA: 32°F to 120°F (0°C to 49°C). •B300-6, B210LP, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (non-condensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system’s standby batteries and the electronic components may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). 01/12/2024 23 Electrical Ratings FOR B300-6 SERIES BASES: Operating voltage: 15 to 32 VDC Standby current: 170 µA maximum FOR B501 SERIES BASES: Operating voltage: 15 to 32 VDC Standby current: 150 µA maximum FOR B200 SERIES BASES: External supply voltage: 16 to 33 VDC (FWR) Standby current: 500 µA maximum. Alarm current: • B200S(A)(-IV)(-WH) –35 mA maximum at high-volume setting –15 mA maximum at low-volume setting • B200S-LF(-IV)(-WH) High-volume setting: –70 mA maximum @ 33.0 VDC –90 mA maximum @ 24.0 VDC –140 mA maximum @16.0 VDC •B200S-LF(-IV)(-WH) Low-volume setting: –15 mA maximum @ 33.0 VDC –20 mA maximum @ 24.0 VDC –25 mA maximum @ 16.0 VDC •B200SR(A)(-IV)(-WH) –35 mA maximum • B200SR-LF(-IV)(-WH) –65 mA maximum @ 33.0 VDC –90 mA maximum @ 24.0 VDC –125 mA maximum @16.0 VDC •B200SCOA(-IV)(-WH) –40mA Max (DC) –70mA Max (FWR) SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification. Sound output: • B200S(A)(-LF)(-IV)(-WH), high-volume*: Greater than 85 dBA minimum. • B200S(A)(-LF)(-IV)(-WH), low-volume*: Greater than 75 dBA minimum. • B200SR(A)(-LF)(-IV)(-WH)*: Greater than 85 dBA minimum. • B200SCOA(-IV)(-WH), high-volume**: Greater than 87 dBA mini- mum. • B200SCOA(-IV)(-WH), low-volume**: Greater than 85 dBA mini- mum *Measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) **Measured in a ULC anechoic room at 10 feet, 24 Volts continuous tone) FOR B224BI, B224RB (A) (-IV) (-WH): Operating voltage: 15 to 32 VDC (powered by SLC) Standby ratings: <450 µA maximum @ 24 VDC Set time (B224RB(A)(-IV)(-WH) only): short delay 60-100 millisec- onds; long delay 6-10 seconds Reset time (B224RB(A)(-IV)(-WH) only): 20 milliseconds maximum Relay characteristics (B224RB(A)(-IV)(-WH) only): two-coil latch- ing relay; one Form-C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0 A @ 30 VDC Page 2 of 3 — DN-60054:K • 7/18/2018 Product Line Information INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: “-IV” suffix indicates Ivory color model. NOTE: “-BL” suffix indicates Black color model. NOTE: “-WH” and “-WHITE” suffix indicates White color model. B210LP: Flanged mounted base. B210LPA: Same as B210LP; ULC listed. B210LPBP: Bulk pack of B210LP, contains 10. B300-6: White, 6” base, standard flanged low-profile mounting base. B300A-6: Same as B300-6, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10;. B300-6-IV: Ivory,6” base, standard flanged low-profile mounting base. B300A-6-IV: Ivory, 6” standard flanged low-profile mounting base, ULC listed. B501-WHITE: White, 4” standard European flangeless mounting base. UL/ULC listed. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B501-BL: Black, 4” standard European flangeless mounting base. UL/ULC listed. B501-IV: Ivory color, 4” standard European flangeless mounting base. UL/ULC listed. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listed. B224RBA-IV: Ivory, relay base, ULC listed. B224BI-WH: White, isolator detector base. B224BI-IV: Ivory isolator detector base. B224BIA-WH: White, isolator detector base, ULC listed. B224BIA-IV: Ivory isolator detector base, ULC listed. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan® protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan® protocol. B200SA-WH: Same as B200S-WH, ULC listed. B200SA-IV: Same as B200S-IV, ULC listed. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. 01/12/2024 24 FlashScan®, NOTIFIER® and System Sensor® are regis- tered trademarks of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of Origin: Mexico NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH, ULC listed. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listed. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A), B300(A)-6 bases. TR300-IV: Ivory, replacement flange for B210LP(A), B300(A)-6-IV bases. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: White, detector color kit. Pack of 10. CK300-IR: White, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-IV: Ivory, detector color kit. Pack of 10. CK300-IR-IV: Ivory, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-BL: Black, detector color kit. Pack of 10. CK300-IR-BL: Black, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL/ULC Listed: S1115 •FM Approved •CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213, 7300-1653:0236 Junction Box Selection Guide Base Models Single Gang DoubleGang 3.5" Oct. 4.0" Oct. 4.0" Sq. 4.0" Sq.with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm B200S, B200SR, B200SCOA YesYesYesYesYesYesNoNoNoNo B501 No No Yes No No Yes Yes Yes Yes No B210LP, B300-6 Yes No Yes Yes Yes Yes No No No No B224BI, B224RB Yes Yes Yes Yes Yes Yes No No No No NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. NOTE: Applies to all model variants “A”, “-BL”, “-LF”, “-IV”, “-WH”, and “-WHITE”. See Product Line Information for detailed model description. 01/12/2024 25 dn-60429:b1 • 07/13/11 — Page 1 of 2 DNR-InnovairFlex Intelligent Non-Relay Photoelectric Duct Smoke Detector Intelligent Devices dn-60429:b1 General The Notifier InnovairFlex DNR intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelec- tric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, tem- peratures of -4 degrees F to 158 degrees F, and a humidity range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sen- sor cover. The Notifier InnovairFlex housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Notifier InnovairFlex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. Features • Photoelectric, integrated low-flow technology • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/s) • Versatile mounting options: square or rectangular configura- tion • Broad ranges for operating temperature (-4F to 158F) and humidity (0% to 95% non-condensing) • Patented sampling tube installs from front or back of the detector with no tools required • Cover tamper signal • Increased wiring space with a newly added 3/4” conduit knockout • Available space within housing to accommodate mounting of a relay module • Easily accessible code wheels on sensor head (sold sepa- rately) • Clear cover for convenient visual inspection • Remote testing capability • Requires com line power only • Accommodates the installation of an addressable relay mod- ule, sold separately, (FRM-1 or NC-100R) for applications requiring a Form-C relay. Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Operating Temperature Range: -4 degrees F to 158 degrees F (-20 degrees C to 70 degrees C) Storage Temperature Range: -22 degrees F to 158 degrees F (-30 degrees C to 70 degrees C) Operating Humidity Range: 0% to 95% relative humidity (non- condensing) Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s) Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detec- tors, all duct smoke detectors accessories are UL listed. DNR(W)s with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RA100Z 0mA 12 mA Max RTS151/RTS151KEY 0mA 12mA Max intelligent innovairflex.jpg Page 2 of 2 — dn-60429:b1 • 07/13/11 ONYX® and NOTIFIER® are registered trademarks and NOTI•FIRE•NET™ is a trademark of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.www.notifier.com Made in the U.S. A. Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. •UL: S911, S635 •ULC: S911, S635 •CFSM: 3242-0075:0221 Product Line Information NOTE: “A or “CDN” suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flowduct smoke detector housing. Requires photoelectric smoke detector (sold separately). NEMA-4. FSP-851R: Remote test capable addressable low-profile photo- electric smoke detector. FSP-851: Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detectorfor FireWarden series panels. NP-100R: Remote test capable addressable low-profile photo- electric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A): Metal sampling tube duct width up to 1 ft (0.3m) DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m) DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m) DST5(A): Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m) DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m) DH400OE-1: Weatherproof enclosure ETX: Metal exhaust tube duct, width 1 ft (0.3 m) M02-04-00: Test magnet P48-21-00: End cap for metal sampling tubes RA100Z(A): Remote annunciator alarm LED RTS151(A): Remote test station RTS151KEY(A): Remote test station with key lock Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. dn-60383:A2 • 06/17/10 — Page 1 of 2 NC-100R(A) Relay Module for FireWarden Series Panels Addressable dn-60383:A2 General The NC-100R(A) Addressable Relay Module provides NOTI- FIER’s FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. • Integral LED “blinks” green each time a communication is received from the control panel and turns on in steady when activated. • High noise immunity (EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. • Direct Decade entry of address: 01 – 99 with the FireWar- den-100-2(C) and 01 – 50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction • The face plate is made of off-white heat-resistant plastic. • Controls include two rotary switches for direct-dial entry of address setting. • The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-100R(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 A direct poll (CLIP mode), 255 A group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (L/R=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A NC-100R(A)60379cov.jpg01/12/2024 28 Page 2 of 2 — dn-60383:A2 • 06/17/10 NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL/ULC Listed: S635. •CSFM approved: file 7300-0028:230. • FM approved. •MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document I56-2593-001 and refer to the SLC Wiring Manual, document 52304. 01/12/2024 29 DN-6999:C • 10/06/2010 — Page 1 of 4 Monitor Modules NMM-100(A), NMM-100P(A), NZM-100(A), and NDM-100(A) for FireWarden Series Panels Intelligent Addressable Devices DN-6999:C General Four different monitor modules are available for Notifier’s Fire-Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3"(3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to bemounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at twoseparate, consecutive addresses in intelligent, two-wire systems. NMM-100(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct Decade entry of address: 01 – 99 on FireWarden- 100-2, 01 – 50 on FireWarden-50. • LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manualfire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor isrequired for supervision of the Style D circuit. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available moduleaddresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LEDindicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 μA (LED flashing), 1 com-munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM-100(A) (Type H)6999cov.jpg01/12/2024 30 Page 2 of 4 — DN-6999:C • 10/06/2010 NMM-100P(A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • Tinned, stripped leads for ease of wiring. • Direct Decade entry of address: 01 – 99 on FireWarden-100-2, 01 – 50 on FireWarden-50. The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat-ing device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM-100P(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir-cuit. NMM-100P(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). NMM-100P(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 μA, 1 communication every 5 seconds, 47k EOL; 600 μA Max. (Communicating, IDCShorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 μA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. NZM-100(A) Interface Module • Supports compatible two-wire smoke detectors. • Supervises IDC wiring and connection of external powersource. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct Decade entry of address:, 01 – 99 on FireWarden- 100-2, 01 – 50 on FireWarden-50. • LED flashes during normal operation. • LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls fromthe control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 μA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrmsmaximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box.6720m101.wmf01/12/2024 31 DN-6999:C • 10/06/2010 — Page 3 of 4 NDM-100(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 μA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 μA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address “26”, then it will automati-cally assign itself to addresses “26” and “27”. NOTE: “Ones” addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu-lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired andmounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S635 •ULC: S635 • FM Approved •CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100) •MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100) Product Line Information NOTE: “A” suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-100P(A): Monitor module, miniature. NZM-100(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. !CAUTION: Avoid duplicating addresses on the system. 01/12/2024 32 Page 4 of 4 — DN-6999:C • 10/06/2010 Notifier® and FireWarden® are registered trademarks and FireWatch™ is atrademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.www.notifier.com Made in the U.S. A. 01/12/2024 33 DN-60942:A • 2/3/2017 — Page 1 of 4 Indoor Selectable-Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications Audio/Visual Devices DN-60942:A SPSWL SPSRL General System Sensor L-Series selectable output speaker strobesand dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. The System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and univer- sal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker compo- nents. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for wall speaker strobes. The low total harmonic distortion of the speaker offers high fidelity sound output while still offering high volume sound out- put for use in high ambient noise applications. System Sensor L-Series makes installation easy. • Attach a universal mounting plate to a 4 × 4 × 2 1/8 inch back box. Flush-mount applications do not require an extensionring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will tem- porarily hold in place with a catch until it is secured with a captured mounting screw. Features • Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation • No extension ring required • Field selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, 185 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) • Speakers offer high fidelity and high volume sound output • Compatible with System Sensor synchronization protocol • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products • Tamper-resistant construction • Updated modern aesthetics Architectural/Engineering Specifications GENERAL L-Series speaker and speaker strobes shall mount to a 4 × 4 × 21/8 inch back box. A universal mounting plate shall be used formounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuitoutputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operatebetween 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Wall-mount speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. SPEAKER The speaker shall be a System Sensor L-Series model _______ dual-voltage transformer speaker capable of operat-ing at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. SPEAKER STROBE COMBINATION The speaker strobe shall be a System Sensor L-Series model __________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall becapable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit modelMDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 01/12/2024 34 Page 2 of 4 — DN-60942:A • 2/3/2017 Hz. The module shall mount to a 411/16 × 411/16 × 21/8 inch back box. The module shall also control two Style Y (class B) cir- cuits or one Style Z (class A) circuit. The module shall syn- chronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS •Standard Operating Temperature: 32°F to 120°F (0°C to 49°C) •Humidity Range: 10 to 93% non-condensing DIMENSIONS, WALL-MOUNT • SP Speaker: 6.5 in x 5 in x 2.3 in. (165 mm x 127 mm x 58 mm) • SP Speaker with Surface Mount Back Box: 6.6 in x 5.1 in x 3.2 in (168 mm x 130 mm x 82 mm) • SPS Speaker/Strobe (including lens and speaker): 6.5 in x 5.0 in x 2.3 in (165 mm x 127 mm x 58 mm) • SPS Speaker/Strobe (including lens and speaker) with Sur- face Mount Back Box: 6.6 in x 5.1 in x 4.55 in. (168 mm x 130 mm x 116 mm) ELECTRICAL/OPERATING SPECIFICATIONS: •Nominal Voltage (speakers): 25 or 70.7 (nominal) •Maximum Supervisory Voltage (speakers): 50 VDC •Strobe Flash Rate: 1 flash per second •Nominal Voltage (strobes): Regulated 12 VDC or regu- lated 24 DC/FWR •Operating Voltage Range (includes fire alarm panels with built in sync): 8 to 17.5 V (12 V nominal) or 16 to 33V (24 V nominal) •Operating Voltage with MDL3 Sync Module: 8.5 to 17.5 V (12 V nominal) or 16.5 to 33V (24 V nominal) •Frequency Range: 400 to 4000 Hz •Power: ¼, ½, 1, 2 watts UL Current Draw Data UL MAX. STROBE CURRENT DRAW (MA RMS) SOUND OUTPUT SPEAKER STROBE SOUND OUTPUT SPEAKER Agency Listings and Approvals The listings and approvals below apply to L-series devices. Insome cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL-Listed: –S4048 Plain Speaker Strobes (Wall) –S4048 Spanish-labeled Speaker Strobes (Wall) –S4048 ALERT speaker strobes • UL/ULC-Listed: –S4048 Speakers (Wall) –S4048 Speaker Strobes (Wall) • FM Approved Product Line Information Note: ULC-listed devices include required French labeling. See Agency Listings for listing details. WALL MOUNT SPWL(A), SPRL(A). Speaker only (White, Red). SPSWL(A), SPSRL(A). Speaker Strobe (White, Red). SPSWL-P(A), SPSRL-P(A). Plain Speaker Strobe (White, Red). SPSWL-ALERT. Speaker Strobe, Amber Lens (White). SPSWL-CLR-ALERT. Speaker Strobe Clear Lens (White). SPSRL-SP. Speaker Strobe, Fuego (White). ACCESSORIES RFPW, RFP. 7 in × 9.5 in Retrofit Plate (White, Red). Candela 8–17.5 Volts 16–33 Volts DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft)77 80 83 86 UL Anechoic (dBA @10 ft)77 80 83 86 ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft)79 82 85 88 UL Anechoic (dBA @10 ft)79 82 85 88 01/12/2024 35 DN-60942:A • 2/3/2017 — Page 3 of 4 SBBSPW, SBBSPR. Surface Mount Back Box for Speakers and Speaker Strobes (White, Red). TRW, TR. Wall Mount Trim Ring (White, Red). Product Drawings: Dimensions and Surface Mounting 60942dimensions.epsWall-Mount Speaker Wall-Mount Speaker Strobe A0522-00.epsWall-Mount Speaker Strobe with SBBSPRL Surface Mount Back 01/12/2024 36 Page 4 of 4 — DN-60942:A • 2/3/2017 NOTIFIER® and SpectrAlert® are registered trademarks andSync•Circuit™ is a trademark of Honeywell International Inc.©2017 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com 01/12/2024 37 Agency Listings Outdoor, Selectable- Output Speaker Strobes and Dual- Voltage Evacuation Speakers for Wall Applications SpectrAlert® Advance outdoor, selectable-output speaker strobes and dual-voltage evacuation speakers meet virtually any outdoor application requirement. Features • Weatherproof per NEMA 4X, IP56 • Rated from -40°F to 151°F • Plug-in design reduces ground faults • Universal mounting plate with onboard shorting spring that tests wiring continuity before devices are installed • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for speaker voltage (25 and 70.7 Vrms) and power settings (1/4, 1/2, 1 and 2 watts) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Tamper-resistant construction • Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic housings, to wall and ceiling mounting options, SpectrAlert Advance can meet virtually any application requirement. Wall-mount outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from −40°F to 151°F. These speakers provide a broad frequency response range, low harmonic distortion and maintain a high sound pressure level at all tap settings to provide accurate and intelligible broadcast of evacuation messages. Like the entire SpectrAlert Advance line, wall-mount outdoor speakers and speaker strobes include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, speaker voltage and power settings, and automatic selection of 12- or 24-volt operation enable installers to easily adapt devices to meet requirements. Next, these devices use a universal mounting plate with an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch knock-outs at the back. A screw-in NPT plug with an O-ring gasket for a watertight seal is included with each back box.10-08-E7320-1653:20175S0 01/12/2024 38 AVDS11301 SpectrAlert® Advance Outdoor Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Outdoor SpectrAlert Advance products shall operate between –40°F and 151°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model ______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems. Speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature from –40°F to 150.8°F. Speaker shall have power taps and wattage settings that are selected by rotary switches. The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048. The speaker shall be suitable for use in air handling spaces and wet environments. Speaker Strobe Combination The speaker strobe shall be a System Sensor Model _____ listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4,000 Hz. Speaker shall have power taps that are selected by rotary switch. The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts. The strobe shall also feature selectable candela output, providing options for 15 or 15/75 candela when operating on 12 volts and 15, 15/75, 30, 75, 110, 115, 135, 150, 177 or 185 candela when operating on 24 volts. The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The speaker strobe shall be suitable for use in wet environments. Physical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Dimensions, Wall-Mount SPS Speaker Strobe 6.0˝ L × 5.0˝ W × 4.7˝ D (including lens and speaker) SP Speaker 6.0˝ L × 5.0˝ W × 2.9˝ D Dimensions, Wall-Mount Weatherproof Back Box 6.5˝ L × 5.5˝ H × 2.9˝ D Electrical/Operating Specifications Nominal Voltage (speakers)25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz Power ¼, ½, 1, 2 watts 01/12/2024 39 AVDS11301 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant (dBA @ 10 ft.)2W 1W ½ W ¼ W Outdoor Speaker 90 87 84 81 Outdoor Speaker/Strobe 89 86 83 80 Dimensions Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 5.00˝.97˝1.84˝ 5.98˝ 5.00˝2.83˝ 1.84˝1.60˝ 5.97˝ Wall-Mount Outdoor Speaker Wall-Mount Outdoor Speaker Strobe 01/12/2024 40 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.AVDS11301 • 09/12 Ordering Information for SpectrAlert® Advance Outdoor Speakers and Speaker Strobes Wall Mount White Red Description SPWK SPRK Outdoor Speaker (includes plastic weatherproof back box) SPWK-R SPRK-R Outdoor Speaker (does not include plastic weatherproof back box) SPSWK SPSRK Outdoor Speaker Strobe, Standard cd (includes plastic weatherproof back box) SPSWK-P SPSRK-P Plain Outdoor Speaker Strobe, Standard cd(includes plastic weatherproof back box) SPSWK-R SPSRK-R Outdoor Speaker Strobe, Standard cd(does not include weatherproof back box) SPSWK-CLR-ALERT —Outdoor Speaker Strobe, Standard cd, Clear Lens, ALERT Printed (includes plastic weatherproof back box) —SPSRHK Outdoor Speaker Strobe, High cd (135,150,177,185) (includes plastic weatherproof back box) Accessories White Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box Notes: All -P models have a plain housing (no “FIRE” marking on cover) “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units, both the device and back box must be replaced. Surface Mounting Wall-Mount Speaker Strobe with Plastic Weatherproof Back Box Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Wall-Mount Speaker with Plastic Weatherproof Back Box Wall-Mount Speaker with Metal Weatherproof Back Box 01/12/2024 Every precaution has been taken to ensure that this literature is accurate and complete. DITEK Corporation assumes no responsibility and disclaims all liability for damages resulting from the use of this information or for any errors or omissions. One DITEK Center 1720 Starkey Road - Largo, FL 33771 Phone: 1-800-753-2345 Direct: 727-812-5000 Technical Support: 1-888-472-6100 www.ditekcorp.com Doc. Number: SPS-100007-005 Rev 3 03/16 ©2016 DITEK Corp. Page 1 of 1 Technical Specifications Service Voltage: 120VAC Single Phase MCOV: 150VAC Protection Modes: All modes – L-G, L-N, N-G Voltage Protection Rating: 600VAC Surge Current Rating: 54,000 Amps per phase Max. Continuous Current: 20 Amps SCCR: 10kA Nominal Discharge Current Rating (In): 3kA Operation Frequency: 40Hz – 400Hz EMI/RFI Filtering Attenuation: Up to 35dB, 100kHz -100MHz Mechanical Characteristics Connection Method: Hardwired, series configuration Housing: ABS Operating Temperature: -40°F - 185°F (-40°C - 85°C) Maximum Humidity: 95% non-condensing Dimensions: 6.87”L x 3.5W x 2.5”H (174050mm x 88.90mm x 63.50mm) Weight: 12.16 oz (0.35kg) Quality, Standards & Approval Agency Approvals: UL1449, cUL, UL1283 SPD Type: Type 2 Component Assembly Standards Compliance: IEEE C62.41.1 –2, IEEE C62.45 Warranty: Ten Year Limited Warranty DITEK’s DTK-120SRD protects dedicated 120VAC power circuits that feed control panels and other critical equipment. The hybrid series design provides maximum critical load protection, and includes dry contacts for remote notification of surge protection status. EMI/RFI filtering ensures clean power for connected equipment. Application  Fire Alarm Panels  Control Panels  120VAC Single Phase Critical Loads  UL Listed Control Panels where UL Recognized Components are Required Product Features  Series design for fast response and best protection  Compact design fits in a variety of control panels  Suitable for use on circuit breakers rated at 10kA AIC  Multi-stage hybrid circuit design  UL1283 EMI/RFI filtering  LED indicates protection status  Form C Dry Contact circuit Accessories  DIN Rail Mounting Kit – Part Number DTK-DRK 01/12/2024 42 FIRE ALARM SHOP DRAWINGS UPBARPANTRY131LOUTSIDESERVICESNACK BAR131KBEER / WINECOOLER131MCHEF &SOUSECHEF131AOFFICE, TBD132BCATERINGDIR. / TBD132CSTORAGE132DSTORAGE132EBULKFREEZER132 FBREAKROOM133RR134DRYSTORAGE 1132ALAUNDRY137FOOD &BEVERAGEOFFICE131IWASHSTATION131JKITCHEN131BAKE SHOP131BDRYSTORAGE131CFREEZER131EBEERCOOLER131DCOOLER131FELECTRICALSERVICE131GMECHANICALSERVICE131HCORRIDOR132BULKCOOLER132GCORRIDOR136AQUATICSSTAFF138VESTIBULE141MEN'S POOLRESTROOM142SHOWER142EACCESSIBLERESTROOM142DURINALS142ATOILET142CTOILET142BTABLESTORAGE129HALL128STORAGE130STAIR 2SERVICE127ASERVICE127BPOOL BAR009POOLSTORAGE140MCH-GMCH-FNEW FIRE ALARM TERMINALCABINET FOR EXTENDINGEXISTING FIRE ALARM CABLING TONEW FIRE ALARM CONTROL PANELLOCATION IN ELECTRICAL ROOM131G.EXISTING FIRE ALARM CABLING TO NEWLOCATION IN ELECTRICAL ROOM 131G. APPROXIMATELY 60' .FIRE ALARMRISER UP TOMEZZININE LVL.D1-1: NEW SMOKEDETECTORE.O.L. S90.427 AMPESE.O.L. S110.309 AMPESEX. E.O.L. SP122.0 WATTSEX. FIRE ALARMCONTROL PANEL &NEW 120VAC SURGESUPPRESSOR.EX. VOICE EVACUATION CONTROLPANEL & NEW MODULES:M1-16: TRIGGERM1-17: MONITORDNC2.0D2.0D4.0E1.0E2.0OFFICE 2213PRINTING /POSTAGE211OFFICE 1214OFFICE 3212LANDING210ACONFERENCEROOM215STAIR 2CORR.210BFIRE ALARMRISER FROMFIRST FLOOR.E.O.L. S100.149 AMPESTYPICAL DEVICE MOUNTING HEIGHTSS S ED S I NG EFIL AFE T 3038 LENOX AVENUE - JACKSONVILLE, FLORIDA 32254 W W W . L I F E S A F E T Y D E S I G N S . C O M - (904) 388-1700 FL: EF-0000878 & 132355-0001-1993 - GA: LVU004677GENERAL DESCRIPTIONAPPLICABLE CODE SUMMARY