Loading...
1600 SELVA MARINA DR ROOF24-0024 FL34538-R2 Product Evaluation Report 4-17-24 METAL ROOFING PRODUCTSMETAL ROOFING PRODUCTSMETAL ROOFING PRODUCTSMETAL ROOFING PRODUCTS 1.888.393.03351.888.393.03351.888.393.03351.888.393.0335 wwwwwwwwwwww....GGGGuuuullllffffCCCCooooaaaassssttttSSSSuuuuppppppppllllyyyy....ccccoooommmm FL34538.01-R2 24ga, 26ga, or 032 Aluminum GulfLokGulfLokGulfLokGulfLokTMTMTMTM over 15/32” (min) plywood Gulf Coast Supply & ManufacturingGulf Coast Supply & ManufacturingGulf Coast Supply & ManufacturingGulf Coast Supply & Manufacturing 14229 SW 2nd Pl G30, Newberry FL 32669 Product DescriptionProduct DescriptionProduct DescriptionProduct Description:::: Nailstrip standing seam panel with nominal 16” max coverage and nominal rib height of 1”. Product MaterialProduct MaterialProduct MaterialProduct Material:::: 24ga or 26ga (min) steel Corrosion resistant per FBC 1507.4.3 where required Or nominally 0.032” aluminum or thicker. FastenerFastenerFastenerFastener:::: #10 x 1-inch fastener or #12 x 1-inch fastener Compliant with FBC 1506.6 where required. Substrate/DeckSubstrate/DeckSubstrate/DeckSubstrate/Deck:::: 15/32” (min) plywood or ¾” (min) SYP wood plank. Maximum Allowable Loads & Installation Requirements:Maximum Allowable Loads & Installation Requirements:Maximum Allowable Loads & Installation Requirements:Maximum Allowable Loads & Installation Requirements: MaterialMaterialMaterialMaterial MethodMethodMethodMethod Fastener PatternFastener PatternFastener PatternFastener Pattern Other RequirementsOther RequirementsOther RequirementsOther Requirements Allowable PressureAllowable PressureAllowable PressureAllowable Pressure 24ga Method A1 #10 fastener in every other slot (±10.25” o.c) ----81.75 81.75 81.75 81.75 PSFPSFPSFPSF 26ga Method B1 #12 fastener in every slot (±4.75” o.c.) ----52.552.552.552.5 PSFPSFPSFPSF 26ga Method B2 #12 fastener in every slot (±4.75” o.c.) Titebond Metal Roof Sealant or similar applied to male rib ----82.5 psf82.5 psf82.5 psf82.5 psf 032 Method C1 #10 fastener in every slot (±5.1875” o.c.) ----52.5 PSF52.5 PSF52.5 PSF52.5 PSF 032 Method C2 #10 fastener in every slot (±5.1875” o.c.) Continuous 032 aluminum clip ----78.5 PSF78.5 PSF78.5 PSF78.5 PSF 032 Method C3 #10 fastener in every slot (±5.1875” o.c.) Titebond Metal Roof Sealant or similar applied to male rib ----116116116116 PSFPSFPSFPSF A factor of safety of 2 has been applied. Evaluated by: Evaluated by: Evaluated by: Evaluated by: David Eng, PE Timberlake Cove, LLC 1317 Edgewater Dr, Ste 2339 Orlando FL FL PE 81377 | FL CA 33344 www.TimberLakeCove.com This item has been digitally signed and sealed by D.E. Eng, PE, on the date indicated. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Page Page Page Page 2222 www.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.com GulfLokGulfLokGulfLokGulfLokTMTMTMTM FL34538.01-R2 Underlayment:Underlayment:Underlayment:Underlayment: Comply with local building code or FBC 1507.1.1 where required. Slope:Slope:Slope:Slope: Comply with local building code or FBC 1507.4.2 where required. ReReReRe----RoofingRoofingRoofingRoofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511, provided the existing roof meets the conditions required by the applicable code. Technical Documentation: Technical Documentation: Technical Documentation: Technical Documentation: This product has been tested to the UL 580 standard by Force Engineering (TST-5328) reports 117-0089T-05 & 117-0337T-10A-C, and by PRI (TST 5878) report 2292T0009 Compliance Statement: Compliance Statement: Compliance Statement: Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2023, 1504.3.2 (nonnonnonnon----HVHZHVHZHVHZHVHZ), as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 – Test for Uplift Resistance of Roof Assemblies • UL 1897 – Uplift test for roof covering systems Design Process:Design Process:Design Process:Design Process: Compare the maximum allowable loads on page 1 to the ASD uplift pressures for the project to determine sufficiency and installation requirements. Alternatively, as an option, the load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-22. Use of these tables assumes that the structure is: Enclosed and conforms to wind-borne debris provisions and is a regular shaped building and is not subject to across-wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. Page Page Page Page 3333 www.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.com GulfLokGulfLokGulfLokGulfLokTMTMTMTM FL34538.01-R2 Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 12:12 Have either a flat roof, or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1:A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 Zone 1:A1 A1 A1 A1 A1 A1 NR NR NR NR NR Zone 2:A1 A1 A1 A1 A1 A1 A1 A1 NR NR NR Zone 2:A1 A1 A1 A1 NR NR NR NR NR NR NR Zone 3:A1 A1 A1 A1 A1 A1 NR NR NR NR NR Zone 3:A1 A1 NR NR NR NR NR NR NR NR NR Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7°, hip roof with max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1:A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 Zone 1:A1 A1 A1 A1 A1 A1 A1 NR NR NR NR Zone 2:A1 A1 A1 A1 A1 A1 A1 A1 A1 NR NR Zone 2:A1 A1 A1 A1 A1 NR NR NR NR NR NR Zone 3:A1 A1 A1 A1 A1 A1 A1 NR NR NR NR Zone 3:A1 A1 A1 NR NR NR NR NR NR NR NR FL34538.01: 24ga GulfLok on 15/32" plywood FL34538.01: 24ga GulfLok on 15/32" plywood FL34538.01: 24ga GulfLok on 15/32" plywood FL34538.01: 24ga GulfLok on 15/32" plywood Use of Load Use of Load Use of Load Use of Load Tables:Tables:Tables:Tables: These load tables are provided as a courtesy to provide one possible prescriptive option for a generic, typical structure without calculating the design pressures. For structures outside the parameters of these load tables (e.g. height above 30 feet), calculate the required allowable design pressure and compare to the maximum allowable loads shown on page 2. These load tables shall not be construed to in any way limit the installation of this product to the cases shown. Instructions:Instructions:Instructions:Instructions: Select the appropriate load table that applies to the structure in question. Determine the design wind speed for the project location. Use the attachment method indicated for that windspeed within each roof zone. Certification of Independence: Certification of Independence: Certification of Independence: Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Exclusions and Limitations: Exclusions and Limitations: Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Installation shall be subject to the local building code and authority having jurisdiction; this report shall not be construed to supersede local codes in force. Page Page Page Page 4444 www.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.comwww.GulfCoastSupply.com GulfLokGulfLokGulfLokGulfLokTMTMTMTM FL34538.01-R2 Method C3 may be used in place of method C2. Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 12:12 Have either a flat roof, or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1:B1 B1 B1 B1 B1 B1 B1 B2 B2 B2 B2 Zone 1:B1 B1 B1 B2 B2 B2 NR NR NR NR NR Zone 2:B1 B1 B1 B1 B1 B2 B2 B2 NR NR NR Zone 2:B1 B2 B2 B2 NR NR NR NR NR NR NR Zone 3:B1 B1 B1 B2 B2 B2 NR NR NR NR NR Zone 3:B2 B2 B2 NR NR NR NR NR NR NR NR Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7°, hip roof with max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1:B1 B1 B1 B1 B1 B1 B1 B1 B2 B2 B2 Zone 1:B1 B1 B1 B1 B2 B2 B2 NR NR NR NR Zone 2:B1 B1 B1 B1 B1 B2 B2 B2 B2 NR NR Zone 2:B1 B1 B2 B2 B2 NR NR NR NR NR NR Zone 3:B1 B1 B1 B1 B2 B2 B2 NR NR NR NR Zone 3:B2 B2 B2 NR NR NR NR NR NR NR NR FL34538.01: 26ga GulfLok on 15/32" plywood FL34538.01: 26ga GulfLok on 15/32" plywood FL34538.01: 26ga GulfLok on 15/32" plywood FL34538.01: 26ga GulfLok on 15/32" plywood Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 12:12 Have either a flat roof, or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1:C1 C1 C1 C1 C1 C1 C1 C2 C2 C2 C3 Zone 1:C1 C1 C1 C2 C2 C2 C3 C3 C3 C3 NR Zone 2:C1 C1 C1 C1 C1 C2 C2 C2 C3 C3 C3 Zone 2:C1 C2 C2 C2 C3 C3 C3 NR NR NR NR Zone 3:C1 C1 C1 C2 C2 C2 C3 C3 C3 NR NR Zone 3:C2 C2 C3 C3 C3 NR NR NR NR NR NR Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7°, hip roof with max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1:C1 C1 C1 C1 C1 C1 C1 C1 C2 C2 C2 Zone 1:C1 C1 C1 C1 C2 C2 C2 C3 C3 C3 C3 Zone 2:C1 C1 C1 C1 C1 C2 C2 C2 C3 C3 C3 Zone 2:C1 C1 C2 C2 C3 C3 C3 C3 NR NR NR Zone 3:C1 C1 C1 C1 C2 C2 C3 C3 C3 C3 NR Zone 3:C2 C2 C2 C3 C3 C3 NR NR NR NR NR FL34538.01: 032 Aluminum GulfLok on 15/32" plywood FL34538.01: 032 Aluminum GulfLok on 15/32" plywood FL34538.01: 032 Aluminum GulfLok on 15/32" plywood FL34538.01: 032 Aluminum GulfLok on 15/32" plywood