469 ATLANTIC BLVD 13 COMM24-0001 MEP PERMIT SET SandS REVISION 2-14-24.EQUIPMENT SCHEDULESYSTEMBASIS OF DESIGNCOOLING CAPACITYAIR FLOWDESIGN TEMPERATURESELECTRICAL DATAHEATING CAPACITYEFFICIENCYMANUFACTURERMODELGROSSSENSIBLECFM% O.A.Ext. SP inH2OEDB °FEWB °FLDB °FLWB °FVOLT / PH / HZMCAMAX.(AMPS)REQUIREDHEATINGCAPACITY (KW)SEERAC-1EXISTING TOREMAINEXISTING TO REMAIN60.0 MBH45.0 MBH2,00026.3%1.0"78.072.055.052.0230 / 1 / 6040503.0EXISTING TOREMAINAHU-12430HP-2TRANE4TTR5060N1000ATAM9A0C60V51DB60.0 MBH45.0 MBH2,0003.8%1.0"78.072.055.052.0230 / 1 / 60325010.015.0AHU-2(NEW)7.515 REMARKS: 1. EXISTING HVAC EQUIPMENT NAMED 'AHU-1" AND "AC-1" DATA WAS PROVIDED BY GC INCLUDING ITS ELECTRICAL SPEC. ANY FIELD DISCREPANCY SHALL BE CONSULTED WITH ENGINEER ON RECORD. MECHANICALCONTRACTOR IS RESPONSIBLE TO FIELD VERIFY THAT EXISTING EQUIPMENT MEET DESIGN SPECIFICATION ON THIS MEP SET OF PLANS. 2. EXISTING HVAC UNIT NAMED "AC-2 +AHU-2" AND ITS DUCTWORK WILL BE REPLACED BY HP-2 AND AHU-2 (NEW) PER THIS PLAN. CAREFULLY DEMOLISH AND REMOVE FROM SITE PER D1.1 ` 3. HVAC DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM SYSTEM (AS REQUIRED, COORDINATE WITH ARCHITECT). OVERALL EQUIPMENT INSTALLATION SHALL COMPLY WITH NFPA 90A-2018. 4. COOLING SET POINT: 75°F. HEATING SET POINT 70°F.DEADBAND 5°F. TOLERANCE +/-1°F. RH 50%. ALL UNITS SHALL HAVE A 7-DAY PROGRAMMABLE THERMOSTAT. CONTROLS SHALL COMPLY WITH FLORIDA BUILDINGCODE, ENERGY CONSERVATION, CHAPTER 4.1.THIS MEP SET DOES NOT INCLUDE STRUCTURAL OR FIRE SAFETYDISCIPLINES. OWNER SHALL COORDINATE WITH ARCHITECH THENEED TO HIRE ANOTHER ENGINEER FOR THOSE DISCIPLINES.2.INSTALLATION SHALL COMPLY WITH STATE AND LOCAL CODE. IFCASE OF ANY DISCREPANCY THAT DOES NOT MEET CODESREQUIREMENTS IT SHALL BE COORDINATED WITH ENGINEER.3.MECHANICAL CONTRACTOR SHALL REVISE THIS ENTIRE MEP SETPLANS AND NOTIFY THE ENGINEER IN CASE OF ANY DISCREPANCYRELATED TO EXISTING CONDITIONS OR SPECIFICATION. THISASSESSMENT SHALL BE COMPLETED BEFORE BID THE PROJECTAND START ANY WORK.4.UNIT LOCATION IS AN APPROXIMATE LOCATION. CONTRACTOR TOCOORDINATE EQUIPMENT INSTALLATION AND FIELD VERIFYEXISTING CONDITIONS.5.EXISTING HVAC EQUIPMENT FIELD AC-2 AND AHU-2 SHALL BEREMOVED AND REPLACED BY NEW EQUIPMENT SPECIFIED IN THISMEP SET. REFER TO D1.1 DEMOLITION PLAN FOR GENERAL NOTES.6.EQUIPMENT SHALL MAINTAIN MANUFACTURER CLEARANCERECOMMENDATION7.COORDINATE THERMOSTAT INSTALLATION TO AVOID HEATEMITTING EQUIPMENT. THERMOSTATS SHALL BE INSTALLED48-INCHES ABOVE FINISHED FLOOR.8.PROVIDE BALANCING DAMPERS IN ALL DUCT BRANCHES. UNITSSHALL BE BALANCED AS SHOWN IN DRAWING.9.RECTANGULAR DUCTWORK SYSTEM SHALL BE FABRICATED FROM2.0" THICK DUCTBOARD W/EXTERIOR FOIL VAPOR BARRIER ANDBLACK COMPOSITE AIR STREAM SURFACE CONTAINING ANANTI-MICROBIAL AGENT.10.ALL DUCTS ARE SMACNA PRESSURE CLASSIFICATION OF 2.0" S.P.,SEAL CLASS "C".11.DUCTWORK SHALL BE INSULATED PER FLORIDA BUILDING CODE:ENERGY CONSERVATION.12.CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO AVOIDCONFLICTS AND INTERFERENCES. VERIFY ALL CLEARANCES ANDDIMENSIONS BEFORE DUCTWORK FABRICATION. PROVIDEOFFSETS TO MEET FIELD CONDITIONS. DIMENSIONS MAY VARYSLIGHTLY DUE TO FIELD MODIFICATIONS AND ADJUSTMENTS.13.THE CONTRACTOR SHALL PROVIDE THE NECESSARYREINFORCEMENT AS REQUIRED TO INSTALL MECHANICALEQUIPMENT AND MATERIALS.14.MAXIMUM LENGTH OF FLEXIBLE DUCTWORK SHALL COMPLY WITH2020 FBC MECHANICAL.15.PROVIDE HANGERS AND SUPPORTS FOR ALL PIPING, DUCTWORKAND EQUIPMENT IN ACCORDANCE WITH ANSI/SMACNA 006,ANSI/MSS SP-58-2018 AND ASHRAE STANDARDS.16.PROVIDE SLEEVE THROUGH WALL PENETRATIONS. SEAL SLEEVETO PREVENT WATER INTRUSION.17.ALL AIR FILTERS SHALL COMPLY WITH SECTION 605 OF 2020 FBC -MECHANICAL.18.DUCTS AND AIR TRANSFER OPENINGS IN FIRE WALLS SHALL BEPROTECTED WITH A LISTED FIRE DAMPER PER FBC MECHANICAL607.19.LICENSED ENGINEER HAS LIMITED RESPONSIBILITIES DIRECTED TOTHE MECHANICAL SPECIFICATION CONTAINS IN THESEMECHANICAL PLAN SHEETS. ENGINEER IS NO RESPONSIBLE FORCONSTRUCTION MEANS, METHOD, PROCEDURES, TECHNIQUES ORSEQUENCES.MECHANICAL GENERAL NOTESEF-16"Ø150 CFM8"Ø200 CFM8"Ø200 CFM14"Ø725 CFM14"Ø725 CFM1,475 CFM18"ØAHU-120"x18"EF-214"x12"12"Ø O.A. DUCT(525 CFM)TROUGH ROOFAHU-2400CFM20"x6"400CFM20"x6"400CFM20"x6"400CFM20"x6"400CFM20"x6"18"x16"16"x16"12"x12"SF-16"Ø O.A. DUCT(75 CFM)TROUGH ROOF22"x22"1,925CFM20"x20"14"x14"10"x10"AIR BALANCE CHART (CFM) FOR VENTILATION SYSTEMUNITAREASERVEDSUPPLYRETURNOUTSIDE AIREXHAUST AIRAHU-1KITCHENBACK KITCHEN2,0001,475525-EF-1KITCHEN---2,585SF-1KITCHEN--2,068-AHU-2DINNING2,0001,92575-EF-2BATHROOM---75TOTALS4,0003,4002,6682,660HVAC EQUIPMENT SYMBOLSKITCHEN HOOD EXHAUST FAN. REFER TO M2.1 FOR DETAILSLOCATION SHALL MEET 2020 FBC MECHANICAL 501.3EXISTING BATHROOM EXHAUST FAN. IT SHALL MEET 75 CFMEXHAUST INTERMITTENT OPERATED. CONTRACTOR TO FIELDVERIFIED SPECIFIED PERFORMANCE AND THAT LOCATION MEET2020 FBC MECHANICAL 501.3KITCHEN HOOD MAKE UP AIR (MUA) SUPPLY FAN. REFER TO M2.1FOR DETAILS LOCATION SHALL MEET 2020 FBC MECHANICAL501.3PLASTIC (POLYMER) SQUARE SUPPLY AIR DIFFUSER W/INSULATION BLANKET, NO SWEAT, NO RUST TECHNOLOGY.NECK PER DRAWING SPECIFICATION. SIMILAR OR EQUIVALENTTO STRATUS STR-C-(SIZE)(W or *BK). USE *W(WHITE) ONACOUSTICAL CEILING AND BATHROOMS. USE *BK(BLACK) ONOPEN CEILING. COLORS SELECTION SHALL BE COORDINATEDAND CONFIRMED WITH ARCHITECTPLASTIC (POLYMER) SQUARE RETURN AIR GRILL, NO SWEAT, NORUST TECHNOLOGY. SIMILAR OR EQUIVALENT TO STRATUSSTR-ERFG-*. USE WHITE ON ACOUSTICAL CEILING. USE BLACKON OPEN CEILING. COLORS SELECTION SHALL BECOORDINATED AND CONFIRMED WITH ARCHITECT.DUCT MOUNTED SUPPLY GRILLE SIMILAR OR EQUIVALENT TO"ADVANTAGE MECHANICAL SUPPLY" MODEL IESA. SIZE PER ASSPECIFIED IN THE DRAWING.DUCT MOUNTED RETURN GRILLE SIMILAR OR EQUIVALENT TO"TITUS" MODEL 45F. SIZE PER AS SPECIFIED IN THE DRAWING.INDICATE THERMOSTAT LOCATION - AHU- #1"Ø PVC CONDENSATE LINE ROUTED AND INSTALLED PERMANUFACTURER INSTRUCTIONSGOOSE NECK DETAIL FOR EXHAUST FANSClean OutDrainVentCONDENSATE DRAIN TRAP TYPICAL DETAILCondensateDrainPanTHIS MEP SET OF PLANS HAS BEEN ELECTRONICALLY SIGNED AND SEALED BYANGEL L. QUINTERO CARTAGENA, PE ON 02/02/2024 USING A SHAAUTHENTICATION CODE.PRINTED COPIES OF THIS MEP SET OF PLANS ARE NOT CONSIDERED SIGNEDAND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANYELECTRONIC COPIES.Ángel L. Quintero, PEDigitally signed by Ángel L. Quintero, PE DN: cn=Ángel L. Quintero, PE, o=Providence Engineering Consulting and Education, PLLC, email=info@PEConsultingEducation.com, c=US Date: 2024.02.02 09:40:11 -05'00'By Toni Gindlesperger at 10:55 am, Feb 14, 2024 By Toni Gindlesperger at 10:55 am, Feb 14, 2024 By Toni Gindlesperger at 10:55 am, Feb 14, 2024 By Toni Gindlesperger at 10:57 am, Feb 14, 2024 NO.P-1SIZEC WDESCRIPTIONITEMPLUMBING FIXTURE SCHEDULESIZEH WWASTEVENTTRAPSELECTION1 12"1/2"1/2"1 12"1 14"EXISTINGEXISTING WALL MOUNTED HAND SINKTO BE RELOCATED. IT SHALL MEET AS MINIMUMTHE PLUMBING SIZES ON THIS TABLE.CONNECT TO EXISTING VENTING AND DRAIN.WHNATURAL GAS COMMERCIAL WATER HEATER75,100 BRU - 75 GALLONS,120V, 1 PHASESIMILAR OR EQUIVALENT TO RHEEM G75-75N1/2" GAS INLET. 180° MAX TEMPERATURESEE GENERAL NOTE #24.NEW WH WILL CONNECT TO EXISTINGSUPPLY WATER PIPING-3/4" IN 3/4"OUT--PROPOSED SCOPE:1)RELOCATE EXISTING SINK (P-1) APPROXIMATELY6'-0 TO RIGHT PER ARCHITECTURAL PLAN. NEWLOCATION SHALL MEET REQUIREMENTSDESCRIBED ON "PLUMBING FIXTURE SCHEDULE".2)REPLACE EXISTING WATER HEATER. REFER TO"PLUMBING FIXTURE SCHEDULE" FORREQUIREMENTS.EXISTING P-1 LOCATIONPROPOSED P-1 LOCATIONWH-1PLUMBING SCOPEOF WORKNG-1NG-2NG-2P-1NG-3NO.NG-1DESCRIPTIONITEMNATURAL GAS FIXTURE SCHEDULESELECTION6 OPEN BURNERS RANGE WITH STANDARD OVENINPUT: 210,000 BTU/hr36" RANGE 6 BURNERS WITH STANDARD OVENMODEL #KR6 TriMark - NATURAL GASNG-2GAS FLOOR FRYERINPUT: 120,000 BTU/hrNATURAL GAS NOTES1.FUEL GAS INSTALLATION AND CERTIFICATION SHALL COMPLY WITH 2020 FLORIDA BUILDING CODE - FUEL GAS.2.FUEL GAS PIPING STEEL SCHEDULE 40 AND SHALL MEET 2020 FLORIDA BUILDING CODE - FUEL GAS, SECTION 403.4.2.3.PIPE SIZING WAS DESIGNED PER 2020 FLORIDA BUILDING CODE -FUEL GAS, FOR A LENGTH OF 60 FT. CONTRACTOR SHALLVERIFY AND COMPARE ACTUAL FIELD DISTANCE. PIPE SIZING SHALL MEET 402.4 (2) OF MENTIONED CODE.4.GAS OUTLETS THAT DO NOT CONNECT TO APPLIANCE SHALL BE CAPPED GAS TIGHT OR OTHERWISE ALLOWED BY 2020FLORIDA BUILDING CODE - FUEL GAS.5.SHUTOFF VALVE SHALL MEET 2020 FLORIDA BUILDING CODE - FUEL GAS SECTION 409.6.FUEL PIPE SYSTEM SHALL BE PROVIDED WITH FLOW CONTROL PER 2020 FLORIDA BUILDING CODE -FUEL GAS SECTION 410.7.NATURAL GAS HEATER SHALL BE VENTED PER 2020 FLORIDA BUILDING CODE- FUEL GAS. REFER TO MANUFACTURER'SMANUAL FOR VENTILATION DETAILSGAS FLOOR FRYERMODEL #KF4-N TriMark- NATURAL GASNG-375 GALLONS WATER HEATERINPUT: 75,100 BTU/hrTO REPLACE EXISTING WATER HEATER (SAME LOCATION)RHEEM, MODEL G75-75NNATURAL GAS1"Ø1 14 "ØEXTEND GAS PIPE TO METER ON GRADE.VERIFY LOCATION WITH LANDLORD'S REPRESENTATIVE.VERIFY GAS COMPANY SUPPLY CAPACITYPIPE LENGTH SHALL NOT EXCEED 60FT. FIELD VERIFYBEFORE START ANY JOB.6 BURNERS RANGE WITHSTANDARD OVEN (NG-1)INPUT 210,000 BTUFLOOR FRYER (NG-2)INPUT 120,000 BTUMANUALSHUT OFF VALVENOTE: INSTALL SEDIMENT TRAP ON MAIN AND APPLIANCES CONNECTION1 1/2 "ØMANUALSHUT OFF VALVEAUTOMATICSHUT OFF VALVEFLOOR FRYER (NG-2)INPUT 120,000 BTUMANUALSHUT OFF VALVE3/4"ØWATER HEATER (NG-3)INPUT 75,100 BTU1 14 "ØPLUMBING GENERAL NOTESTHE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE ANDLOCAL CODES.UTILITIES AND SERVICES INDICATED ARE TAKEN FROM AS-BUILT CONDITION.UNFORESEEN CONDITIONS PROBABLY EXIST AND NEW WORK MAY NOT BEFIELD LOCATED EXACTLY AS SHOWN ON DRAWINGS. COOPERATION WITHOTHER TRADES IN ROUTING AND BURIAL DEPTHS, AS DETERMINEDDURING CONSTRUCTION, WILL BE NECESSARY.FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBINGSYSTEMS, WHICH ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTIONAND EXTENSION OF THE NEW WORK.NOTIFY OWNER AT LEAST 24 HOURS (MINIMUM) PRIOR TO INTERRUPTING EXISTINGSERVICE. SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZEDISRUPTION OF SERVICES.PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN ISSCHEMATIC AND IS NOT INTENDED TO INDICATE EXACT ROUTING.CONTRACTOR SHALL PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGSREQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES.VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONS ANDOTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOIDINTERFERENCES.PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITEUTILITIES.CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPTAS SPECIFICALLY NOTED.PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS ORABOVE NON-ACCESSIBLE CEILINGS.FLASH AND COUNTER-FLASH ROOF PENETRATIONS.SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS ANDMOUNTING HEIGHTS.ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROMEPLATED.PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCALCODES. INSTALL CLEANOUT WITH COVER FLUSH TO FINISH SURFACE.SET FLOOR DRAINS BELOW FINISHED FLOOR TO ALLOW FORFLOOR SLOPING TO THE DRAIN.COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS,TRANSFORMERS, ETC.) PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANYPIPING OVER ANY ELECTRICAL PANELS UNDER ANY CIRCUMSTANCES.ANY PIPING RUN OVER PANELS SHALL BE RE-ROUTED AT NO ADDITIONALCOST. COORDINATE WATER HEATER INSTALLATION WITH ELECTRICALPANELS.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.17.18.19.WATER PIPING SHALL BE CPVC ASTM D2846 / D2846M APPROVED FOR HOT ANDPROVIDE WATER HAMMER FOR QUICK-CLOSING VALVES PER 2020 FBC-PLUMBING 604.920.ALL SOIL, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC DWV.21.SANITARY PIPING BELOW GROUND FLOOR SLAB SHALL BE SCHEDULE 40PVC DWV SOIL PIPE AND FITTINGS.SANITARY DRAINAGE SYSTEMS SHALL BE TESTED PER 2020 FBC - PLUMBING,SECTION 312.SLOPE OF HORIZONTAL DRAINAGE PIPE SHALL CONFORM WITH 2020 FBC -PLUMBING SECTION 704.VENT PIPE SIZING SHALL COMPLY WITH 2020 FBC - PLUMBING, SECTION 906.22.23.24.POTABLE DISTRIBUTION SHALL BE DISINFECTED PER 2020 FBC - PLUMBING,SECTION 602.WATER HEATER SHALL BE EQUIPPED WITH TEMPERATURE CONTROLS PER2020 FBC - PLUMBING, SECTION 501. 120° F SHALL BE DESIGNED AS MAX.OPERATING TEMP. IF OPERATIONAL TEMPERATURE WILL BE SET AT 140°F,KITCHEN AND BATHROOM SINKS (PLUS OTHER FIXTURES WITH HUMANCONTACT) SHALL BE EQUIPPED WITH A MIXING VALVE TO BE SET TO 110°F.NEVER OPERATE WATER HEATER OVER 140°F.25.LICENSED ENGINEER HAS LIMITED RESPONSIBILITIES DIRECTED TO THEMECHANICAL SPECIFICATION CONTAINS IN THESE PLUMBINGPLAN SHEETS. ENGINEER IS NO RESPONSIBLE FOR CONSTRUCTIONMEANS, METHOD, PROCEDURES, TECHNIQUES OR SEQUENCES.COLD WATER DISTRIBUTION.P1CONNECT TO EXISTINGSANITARY DRAIN PER"PLUMBING FIXTURESCHEDULE"2"Ø2"ØCONNECT TO EXISTINGVENT SYSTEM. 1 12"MINIMUM.P11/2"ØCW &HWCONNECT TO EXISTINSUPPLY WATER PIPINGPER "PLUMBING FIXTURESCHEDULE"By Toni Gindlesperger at 10:57 am, Feb 14, 2024