Loading...
1624 Atlantic Beach Dr ROW24-0020 PermitOWNER:ADDRESS:CITY:STATE:ZIP: ATLANTIC BEACH PARTNERS LLC 414 OLD HARD RD FLEMING ISLAND FL 32003 COMPANY:ADDRESS:CITY:STATE:ZIP: SOUTHEAST UTILITIES OF GEORGIA, INC.5934 RICHARD ST JACKSONVILLE FL 32216 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 1120 ATLANTIC BEACH COUNTRY CLUB UNIT 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1624 ATLANTIC BEACH DR RIGHT OF WAY SINGLE OR TWO FAMILY RIGHT OF WAY COMCAST - UNDERGROUND COAX $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/22/2024 PERMIT NUMBER ROW24-0020 ISSUED: 7/22/2024 EXPIRES: 10/20/2024 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: 2 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL Notes: Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code. 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. Full site to be grassed. 4 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL Notes: Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of- way for construction parking. 5 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 6 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 7 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL Notes: All construction debris must be removed from job site by Contractor. 8 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 2 of 2Issued Date: 7/22/2024 PERMIT NUMBER ROW24-0020 ISSUED: 7/22/2024 EXPIRES: 10/20/2024 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 COMCAST PERMIT REQUEST FOR LOCATION:1624 ATLANTIC BEACH DR, ATLANTIC BEACH,FL 32233THESE PLANS WERE PREPARED UNDER THERESPONSIBLE CHARGE OF COMCAST.SANTA ROSAOKALOOSAWALTONHOLMESWASHINGTONBAYCALHOUNJACKSONGADSDENLIBERTYGULFFRANKLINWAKULLALEONJEFFERSONTAYLORMADISONHAMILTONSUWANNEELAFAYETTEDIXIEGILCHRISTCOLUMBIAUNIONBAKERBRADFORDALACHUALEVYMARIONPUTNAMCLAYDUVALNASSAUST JOHNSFLAGLERVOLUSIALAKESUMTERCITRUSORANGESEMINOLEOSCEOLAPASCOHERNANDOPOLKHILLSBOROUGHPINELLASINDIAN RIVERBREVARDST LUCIEMARTINOKEECHOBEEHIGHLANDSHARDEEMANATEESARASOTADESOTOGLADESCHARLOTTELEEHENDRYPALM BEACHBR/WARDCOLLIERMIAMI-DADEMONROEESCAMBIAINDEX·Sheet 1:·Sheet 2:·Sheet 3·Sheet 4-6:Cover-TitleNotes & SymbologyConstruction Plans (Atlantic Beach Dr)TCP MOTVICINITY MAPNO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDNO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDDUVAL COUNTYATLANTIC BEACH DRWORK LOCATION NO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDNO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDGENERAL NOTES:ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36" .ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BOREMACHINE, AS WELL AS COUNTY APPROVED CONDUIT.ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 7' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PIT AND WILL USE 2" HDPE CONDUIT AT 36" DEPTH USING A 51/4" DRILL HEAD.ALL PROPOSED AERIAL WILL BE 0.700" DIAMETER AND WILL BE LASHED TO 0.250" STEEL STRAND CABLEUSING 0.125" STANDARD GALVANIZED LASHING WIRE.ALL PROPOSED AERIAL CATV CROSSING ROAD/WAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0"ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0"LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TOCONSTRUCTION.NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION.ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTERCONDITION BY GRADING AND RE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITHBERMUDA SOD. "ALL CRACKED SIDEWALK IS TO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OFWORK COMPLETION."WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONINGEQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THECONTRACTOR.CONSTRUCTION NOTES:IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THERIGHT-OF-WAY AND EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIESCAUSED BY THE WORK THROUGH FIELD VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES INCASE OF OPEN EXCAVATION. VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THECASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THEDRILLING EQUIPMENT.THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACTWITH DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALLNOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATORSHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTIES/STATE INFRASTRURE AND THEEXISTING FACILITIES OF THE OTHER UTILITY COMPANIESNO REAMER USEDTHE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITHTHE FLORIDA DEPARTMENT OF TRANSPORTATION 2023-2024INDEX 102-602 & 101-660 AND APPLY TO:1624 ATLANTIC BEACH DR, ATLANTIC BEACH, FL 32233BORE PITGAS/WATER/SS/ELECTRIC VALVETREE/BUSHESEXISTING POLEEXISTING COMCAST PEDESTALNEW RISER ATTACHED TO POLEEXISTING IRRIGATION VAULTEXISTING COMCAST VAULTEXISTING UTILITY VAULT/PEDESTALNEW COMCAST LOW PROFILE NEW COMCAST PEDESTALNEW COMCAST VAULTPOWER SUPPLY W/ METERPHMONUMENTUNIDENTIFIED MANHOLEWATER METERSTORM DRAIN MANHOLESANITARY / STORM SEWER MANHOLECATCH BASINSEWER CLEAN OUTWATER MANHOLEELECTRIC MANHOLETRANSFORMERFIRE HYDRANTTRAFFIC SIGNAL COMBINATIONSTREET LIGHTGAS METERPOTHOLESTREET SIGNNEW POLETELCO MANHOLECULVERTROADWAY CENTER LINEEXISTING CATV LINEEXISTING FENCELINEEXISTING WATER LINEEXISTING STORM DRAINEXISTING SANITARY SEWEREXISTING IRRIGATION SYSTEMEXISTING GAS SYSTEMEXISTING ELECTRICAL SYSTEMEXISTING TELEPHONE SYSTEMPROPERTY LINELINETYPESPROPOSED BORE ROUTEPROPOSED AERIAL ROUTEEASEMENT LINER/W LINEBOCRAILROAD NO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDNO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDR/WBOCC/LBOCR/WR/WBOCC/LBOCR/WD/W1618161916241625210' ± TOTIMBER BRIDGE LN355' ± TOCOASTAL OAK LNATLANTIC BEACH DR5'S/W16301637D/WD/WD/W4'10'8'70'1+2046'0+00BEGIN UG HERE ATPROPOSED CATV PED #10+74EXISTING CATV PED #11+35END UG HERE ATEXISTING CATV PED #212'22'60'22'PROPOSED BORE PLACEMENTFOR 135' ALONG & CROSSINGATLANTIC BEACH DRAT MIN DEPTH OF 36"USING 1-2" 13.5 SDR ROLL PIPEWITH 0.700" COAXIAL CABLE19'19'60'19'19'16'16'9'10'D/W14'18'1'18'0+7015'BOC BOC 60'R/W R/WC/LR/W 22'19'BOC BOC 0''12''24''36''48''60''72''84''0''12''24''36''48''60''72''84''R/W 19'CATV WATER SD 10'4'SS 10'8'12'TELCO CATV 18'16'GAS GAS 16'5'S/W 4 OF 4 4 OF 45 OF 65 5 OF 6 6 OF 66