Beach Ave 1785 - Some Thumbnails Have Errors r
Be
Baker Engineering & Consultnl!, P.L.
STRUCTURAL ENGINEERING SERVICES
12. Use(2) Simpson HTS20 straps at each end of Truss GO I.
13. Use(2) Simpson HTS20 straps at each end of Truss G03.
14. Use(2) Simpson HTS20 straps at each end of Truss H03.
15. Use(2) Simpson HTS20 straps at the left end of Truss HPA.
Should you have any questions or need additional information, please call me directly at 904-
398-9837.
Sincerel
�p
�L
Tamara G.Baker,Ply
Structural Engineer
FL Cert.No. 60000
1628 San Marco Blvd. Suite 13 Jacksonville, Florida 32207
Phone: 904.398.9837 Fax: 904.398.9838
9
Baker
ENGINLERiNG Baker engineering & Consulting, •P L
•
&Ce xdr ng
STRUCTURAL ENGINEERING SERVICES
September 29,2005
Mr. Robert Leinenweber
Jacksonville Beach,Florida
RE: The Gaynon Residence(Job#05-125)
Dear Building Inspector:
This letter shall serve as the Engineers' acceptance of the following roof truss up-lift
connection revisions:
1. Use (2) Simpson H8 or H2.5A connectors each end of each truss, typical
unless noted below.
2. Use(2) Simpson HTS20 strap at middle of support of Truss AO 1.
3. Use(1)Simpson HTS20 strap at middle of support of Truss A02.
4. Use(1) Simpson HTS20 strap at middle of support of Truss A03.
5. Use (2) Simpson HTS20 straps at left end of Truss BO1. Use Simpson
HGUS28 Hanger at right end of Truss BO I.
6. Use(1) Simpson HTS20 strap at the left end of Truss B02.
7. Use(2) Simpson HTS20 straps at each end of Truss COI I.
8. Use(2) Simpson HTS20 straps at each end of Truss DO1.
9. Use(2) Simpson HTS20 straps at right end of Truss D04.
10. Use(2) Simpson HTS20 straps at each end of Truss EO 1.
11. Use(1) Simpson HTS20 strap at the left end of Truss EPA.
1628 San Marco Blvd. Suite U Jacksonville, Florida 32207
Phone: 904.398.9837 Fax: 904.398.9838
City of Atlantic Beach
Building Department
De artment
r}° Certif cate of Occupancy
This Certificate issued pursuant to the requirements of Section 110.2 of the
Florida Building Code certifying that at the time of issuance this structure
was in compliance with the various ordinances of the City regulating
building construction or use. For the following:
Date: August 18, 2006
Owner: Gpynon, Glenn & Darlene, Eastern Shores Construction
Address: 200 Belvedere St, Atlantic Beach, Florida 32233
Construction Type: Wood Frame
Use Classification: Residential
Permit Number: -31015
STYN MAKOWSKI, C.B.o
Building Official
LARRY HIGGINS
Deputy Building Official
Post in a conspicuous space.
Schlueter, Jennifer
From: Kaluzniak, Donna
Sent: Friday, March 18, 2005 10:28 AM
To: Schlueter, Jennifer
Subject: FW: Sewer&water inspection for 890 Begonia St.
From: Walker,Chris
Sent: Friday,March 18,2005 10:27 AM
To: Kaluzniak,Donna
Subject: RE: Sewer&water inspection for 890 Begonia St.
Yes it was fine.
-----Original Message-----
From: Kaluzniak,Donna
Sent: Friday,March 18,2005 10:26 AM
To: Walker,Chris
Subject: FW: Sewer&water inspection for 890 Begonia St.
Chris, was this OK
From: Receptionist
Sent: Tuesday,March 15,2005 8:41 AM
To: KaluzniaK Donna
Cc: Walker,Chris
Subject: Sewer&water inspectifor 890 Begonia St.
...__
Donna,
I mistakenly took an inspection for Larry yesterday for the above address. The permit#is 03-26721; contractor:
Chris Fraze& Sons; owner: H. H. &A. Construction; contact number: 866-7796. 1 scheduled them for this morning
and will call to let them know I sent info over to you. Thanks, Bonny
1
gw
- ;J4
ILI
20'-0"
9 ,.. 1�,• 61 D� m
"IPE
e '
196 , OT 1 X _
LOT 2
City of Atlantic Beach
Planning and Zoning Departmerd
This; approval verifies compliants with applicaable
zoning subdivision and Other local land
development regulations, but does not constitute
apPlovr I for the issuance of permits. Compliance
v"'ith Florida Building Code and all other applicable
I('Ca!, Sate and Federal permitting requirements
nu.Fsi bt verified by signature of the City of Atlantic
;each Building Of iai prior to suance of is
Building Permit.
Approved By:
mm a Opment
Lj