Beach Ave 1876 PERMIT WORKSHEET Certificate of Occupancy_
Job Address: n Type Work: ���
Property Owner: Phone #
Contractor: Phone #
Permit#: Il5_ Date Issued:
Tree Permit#
Foundation Permit#
Demolition Permit# �POnI�
BUILDING ELECTRIC # 2 MECHANICAL # PLUMBING # .7
p Tem .Power# 1g 5
Footing l JEA Release
Date3• b6
Temp. Power Z
Srab Letter Rec'd. Underslab �Q•3 •Q
Tie Beam Temp Pole# 0 to
a
Lintel 1 ti0 '0 JEA Release Gas Piping
Date
Nailing/ R�1 v0 5 Water/
Sheathing 'L•13.0 Sewer
Rough/
Framing Rough Rough Topout
Insulation �,�•� JEA Release
Date
Building Electric Mechanical Plumbing
Final Final Final Final
JEA Release
tC 1�.010 Date 3 0
Drainage Inspection:
Pool Permit#
Inspections: Steel Final
Elec./Grounding Final
Roofing Permit#
5,19.0 Inspect: Nailing/Sheathing Final — �
Fire Inspection:
Failed Inspections: (�--�
N �
An �, IW9iO
w
Q.
w
4 �L
o� -407 /P+ 1p 7
-a
CA
O S
114
L DT 4f5/ Lor 5 :2
tt e
� $ Cob"COO'0►�"��., .. � / - �+MV
�J
to/.a_u._
-� • ' I'RoFr� ELS. - '�
N tp, � � .
N
5 8RG . 5�•
, .
1 0T. 5�a
5 / TIffPLA4 U�Zir�l� Gc��IsT,
2 ��-
T
os
40" 1
T
Ake
�o10076. , oQ
O
Xv '44
`
DA tID ST
oR REEr
Ol"INANOE NUM SED BY fat Ml�G` i�
A \ $OERL y pARKBER ss_7s l
RIC,H7 OF WAYNUE) } 400
O IN A
1310,
Moi op s R oN 10
\ h'o S zo fi' o fl 4� .'�"`�
T
3 8r FS1C�F ST �F'T FT • �'2' �c�� �,�
e
00r Mc£oRr� aim
N
l J?+
J
SURVEY. .06 T
C� OUI 22� �`�FFTF �\
. PAGES 2 AND" ` op U
V UNES AS PER D r,4k S
HEREON
XAPPEARS
(AREA
R FLOOD PLAIN
)ErERMINED FROM
RATE MAP
I
_RFR 1?p07g pool rOT Sb,2�� THIS SBR VE
GLENN GA yNot4. MADE FOR THE BEN
EFt r
n
Project Summary Date:
Entire House By:
DONOVAN HEATING AND AIR CONDITIONG
315 6 TH AVE SOUTH,JACKSONVILLE BEACH,FL 32250 Phone:904241-3785 Fax:904241-3745 Email:billCdonovanac.com Web:www.donovanac.com
Project • •
For: GLENN GAYNON
BELVEDERE STREET,ATLANTIC BEACH, FL 32233
Notes:
Design Information
Weather: Jacksonville, Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 25 OF Outside db 96 OF
Inside db 70 OF Inside db 72 OF
Design TD 45 OF Design TD 24 OF
Daily range L
Relative humidity 55 %
Moisture difference 52 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 49197 Btuh Structure 42041 Btuh
Ducts 6888 cfm Ducts 8137 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh AED excursion 0 Btuh
Equipment load 56084 Btuh Use manufacturer's data n
Rate/swing multiplier 1.01
Infiltration Equipment sensible load 42462 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 7571 Btuh
Ducts 896 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft') 3172 3172 Equipment latent load 8467 Btuh
Volume(ft') 30862 30862
Air changes/hour 0.35 0.35 Equipment total load 50929 Btuh
Equiv.AVF(cfm) 180 180 Req.total capacity at 0.70 SHR 5.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Trane Make Trane
Trade XE 1000 Weathertron Trade XE 1000 Weathertron
Model TWRO60D Cond TWR060D
Coil TWE060P13
Efficiency 8.4 HSPF Efficiency 10.9 SEER
Heating Input Sensible cooling 43050 Btuh
Heating output 61000 Btuh @ 47°F Latent cooling 18450 Btuh
Temperature rise 31 OF Total cooling 61500 Btuh
Actual air flow 1800 cfm Actual air flow 1800 cfm
Air flow factor 0.032 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0.10 in H2O Static pressure 0.10 in H2O
Space thermostat Load sensible heat ratio 0.83
Boid/italic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wrlo"tsoft Right-Suite Residential 5.9.35 RSR39613 2005-Jul-19 12:50:39
CAMy DocumentslWrightsoft HVAC\GAYNON.rrp Calc=MJ8 Orientation=E Page 1
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* =88.4
The higher the score,the more efficient the home.
GLENN GAYNON, BELVEDERE STREET, ATLANTIC BEACH, FL, 32266-
1. New construction or existing New - 12. Cooling systems
2. Single family or multi-family Single family - a. Central Unit Cap:36.0 kBtu/hr _
3. Number of units,if multi-family 1 - SEER-- 14.00 _
4. Number of Bedrooms 4 _ b. Central Unit Cap:30.0 kBtu/hr _
5. Is this a worst case? No _
SEER: 14.00 _
6. Conditioned floor area(ft2) 3237 ft2 c. N/A
7. Glass area&type Single Pane Double Pane _ _
a. Clear-single pane 0.0 ft2 0.0 ft2 _ 13. Heating systems
b. Clear-double pane 0.0 ft2 0,0 ft2 _ a. Electric Heat Pump Cap:36.0 kBtu/hr _
c. Tint/other SHGC-single pane 39.0 ft2 491.0 ft2 _ HSPF:8.00 _
d.Tint/other SHGC-double pane b. Electric Heat Pump Cap:24.0 kBtu/hr _
8. Floor types - HSPF:8.00 _
a. Slab-On-Grade Edge Insulation R=0.0, 142.0(p)ft _ c. N/A
b.N/A _
c. N/A 14. Hot water systems
9. Wall types _ a. Electric Resistance Cap:40.0 gallons _
a. Frame,Wood,Exterior R=21.0,2069.0 ft2 _ EF:0.97 _
b.Concrete,Int Insul,Exterior R=11.0, 1127.0 ft2 _ b.N/A
c. N/A _
d.N/A _ c. Conservation credits _
e. N/A (HR-Heat recovery,Solar
10. Ceiling types _ DHP-Dedicated heat pump)
a. Under Attic R=30.0, 1666.0 112 _ 15. HVAC credits MZ-C,MZ-H _
b.N/A _ (CF-Ceiling fan,CV-Cross ventilation,
c. N/A HF-Whole house fan,
11. Ducts - PT-Programmable Thermostat,
a. Sup:Unc. Ret:Unc. AH:Interior Sup.R=6.0, 15.0 ft _ MZ-C-Multizone cooling,
b.N/A MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed(or exceeded) DI-VUE SIr
in this home before final inspection.Otherwise,a new EPL Display Card will be completed 4�y , qr
based on installed Code compliant features. ? o
Builder Signature: Date:
1
Address of New Home: City/FL Zip: �CpD WE tq�
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater(or 86 for a US EPADOE EnergyStar7mdesignation),
your home may qualify for energy efficiency mortgage(EEM)incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucfedu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 850/487-1824.
EnergyGauge®(Version: FLRCSB v3.30)
FORM 60OA-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: BELVEDERE STREET,ATLANTIC BEACH,FL,32266- PERMIT#:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
Exterior Windows&Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft.window area; .5 cfm/s .ft.door area.
Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surround:extends
foundation&wall sole or sill plate;joints between exterior wall panels at comers
penetrations;between wall panels&top/bottom plates;between walls and floor.
EXCEPTION:Frame walls where a continuous infiltration barrier is installed tha
from,and is sealed to the foundation to the top plate.
Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss orjoint members.
EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter,penetrations and seams.
Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases,
soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate;
attic access.EXCEPTION:Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter,at penetrations and seams.
Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a
sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from
conditioned space,tested.
Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.
Additional Infiltration regts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded W all residences.
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with efficiency requirements in Table 6-12.Switch or clearly marked circuit
breaker electric or cutoff as must be provided.External or built-in heat trap required.
Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools
must have a pump timer.Gas spa&pool heaters must have a minimum thermal
efficient of 78%.
Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically
attached,sealed,insulated,and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics:R-6 min.insulation.
HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system.
Insulation 604.1,602.1 Ceilings-Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides.
Common ceiling&floors R-11.
EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge D/FlaRES'2001 FLRCSB v3.30
FORM 600A-2001
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: BELVEDERE STREET,ATLANTIC BEACH, FL,32266- PERMIT#:
BASE AS-BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
4 2746.00 10984.0 40.0 0.97 4 1.00 2491.22 1.00 9964.9
As-Built Total: 9964.9
CODE COMPLIANCE STATUS
BASE AS-BUILT
Cooling + Heating + Hot Water - Total Cooling + Heating + Hot Water - Total
Points Points Points Points Points Points Points Points
20386 13814 10984 45184 T 9968 11990 9965 31923
PASS
O4,tIAE STA?(
S fa
a
EnergyGaugeTm DCA Form 60OA-2001 EnergyGaugeWFIaRES'2001 FLRCSB v3.30
FORM 60OA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: BELVEDERE STREET,ATLANTIC BEACH, FL,32266- PERMIT#:
BASE AS-BUILT
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Slab 142.0(p) 8.9 1263.8 Slab-On-Grade Edge Insulation 0.0 142.0(p 18.80 2669.6
Raised 0.0 0.00 0.0
Base Total: 1263.8 As-Built Total: 142.0 2669.6
INFILTRATION Area X BWPM = Points Area X WPM = Points
3237.0 -0.59 -1909.8 3237.0 -0.59 -1909.8
Winter Base Points: 22017.6 Winter As-Built Points: 25476.4
Total Winter X System - Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(DM x DSM x AHU)
25476.4 0.600 (1.069 x 1.169 x 0.93) 0.426 0.950 7193.7
25476.4 0.400(1.00 x 1.169 x 1.00) 0.426 0.950 4795.8
22017.6 0.6274 13813.8 25476.4 1.00 1.162 0.426 0.950 11989.5
EnergyGauge'rm DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30
HP OfficeJet 7410 Log for
Personal Printer/Fax/Copier/Scanner Information Systems
904-247-5845
Jun 28 2006 10:08AM
Last Transaction
Date Time Type Identification Duration Pages Result
Jun 28 10:02AM Fax Sent 96654470 5:25 5 Jammed
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
r ;)
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 06-00033340 Date 6/22/06
Property Address . . . . . . 200 BELVEDERE ST
Tenant nbr, name . . . . . . EARLY POWER
Application description . . . ELECTRIC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
Owner Contractor
------- -- - --- -- -- -- - -- --
BROOKS & LIMBAUGH ELECTRIC CO
42 WEST 8TH STREET
ATLANTIC BEACH FL 32233
(904) 241-9051
--- - - --- ----- --- - - --- -- -- - - - - - - - - - - ----- ------ - - - - - -- - -- - - - - ---- - ------------
Permit . . . . . . ELECTRICAL PERMIT
Additional desc . .
Permit Fee . . . . 300 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Fee summary Charged Paid Credited Due
------- ---- -- - -- - -- - - - - -- - - - -- ----- - - - - ---- - -- - - ---------
Permit Fee Total 300 . 00 300 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 300 . 00 300 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
rt�<% v rr�t� j�1(�llll �l� ff>�� xrc� fsctc.
June 20, 2005
Building Official
City of Atlantic Beach
800 Seminole Road
Atlmrtic Beach,Fl. 32233
Building Official,
This letter is concerning 200 Belvedere Street for Eastern Shores Construction Inc., and Robert
Leinenweber.We have an electrical permit#05-00031247 on file for the new residence.We are
requesting power be released for the premises to allow for the construction project to be completed.
All electrical circuits are capped off and are in a safe condition. If you need to contact me my cell#
is 219-5044.
ank o ,
Jvo
C
4Alex S. Li baugh
Master electrician
EC 130002296
r.
7Baker En ineerin & onsultiENGIA[C �w � 5if
STRUCTURAL ENGINEERING SERVICES
February 21,2006
Mr. Robert Leinenweber
C/o City of Atlantic Beach
Building Department
Attention: Mr. Larry Higgins
800 Seminole Road
Atlantic Beach,Florida 32233-5445
RE: The Gaynon Residence(BEC Job 405-125)200 Belvedere Street
Dear Building Inspector:
This letter shall serve as the Engineers' acceptance of the following:
1. On the west wall in the second level bathroom, only (1) threaded rod is required.
Two Simpson MSTA flat straps shall be added to the exterior of the wall.
2. On the south wall in the second level spare bedroom, only (1) threaded rod is
required. Two Simpson MSTA flat straps shall be added to the exterior of the
wall.
Should you have any questions or need additional information, please call me directly at 904-
398-9837.
Sincerely,
aker, E
Structural Engineer
FL Cert.No. 60000
1628 San Marco Blvd. Suite 13 .Jacksonville, Florida 32207
Phone: 904.398.9837 Fax: 904.398.9838
L7Baker . Baker Engineering Consultin P.L.
ENGINEERINRG S.w �. (j''
C uWrii fo j".r�
STRUCTURAL ENGINEERING SERVICES
February 21,2006
Mr. Robert Leinenweber
C/o City of Atlantic Beach
Building Department
Attention: Mr. Larry Higgins
800 Seminole Road
Atlantic Beach, Florida 32233-5445
RE: The Gaynon Residence(BEC Job#05-125)200 Belvedere Street
Dear Building Inspector:
This letter shall serve as the Engineers' acceptance of the following:
1. On the west wall in the second level bathroom, only (1) threaded rod is required.
Two Simpson MSTA flat straps shall be added to the exterior of the wall.
2. On the south wall in the second level spare bedroom, only (1) threaded rod is
required. Two Simpson MSTA flat straps shall be added to the exterior of the
wall.
Should you have any questions or need additional information, please call me directly at 904-
398-9837.
Sincerely,
Tarlara G.Baker, PE
Structural Engineer
FL Cert.No.60000
1628 San Marco Blvd, Suite 13 Jacksonville,Florida 32207
Phone: 904.398.9837 Fax: 904.398.9838