Loading...
SARGO RD 452 (4) MAP SHOWING BOUNDARY SURVEY OF LO'l 20. BLOCK 18, RE,ILA P OF PAR I or ROM PAI.M!� UNI I TWO A. A.$ RLCOI?f)CD IN III AT BOOK 31, PAGES 16. IbA ii-irzotj,",'H 161). OF 'I'lli CURRENI RIXORD!� Or DUVAL COUNTY. FIORIDA, CERTMED TO: MICHAEL A. MERRILUS RESOLIRC17. BANK ATTORNIYS' TITLE. INSURANCL rUNO. INC. MI LIAM C. NOE, JH. SARGO RAOD (60.0' RIGHT ot wAY) s b7'16'02" E 80-65' (PLAT) CORNER Or INTERSECTION FO" 1/2-IRON PIPE FOUND 1/2-I*M PIPE S 07*13'11" E 80.72"(MEASURED) FOUND 1/2-RON Pipe NO IDENIVICATION NO d)ENTIF9CA!2!,g.A NO 1KNIII'MAliON X —X- 1.7' 5 07, 330.93-(MCAWRED) OX S 07'16'02" 1 r 331.40' (PLAI) x 0 < 23' WALOWC 0- RE57WMN LINIE Lij J'a,I% cc M 14-4- (n b 9 V) X— Lc < x < uJ -. .. , ';,'-_'WrEr'STORY. Lij < -j rn -1 E CARACE 2 ONE STORY U Is IVIASON�Y to 0 cy) 12.5' POSTED # 452 Go 0 04 vi LOT 19 0 30.3, cr) C" BLOCK 18 uj 20 COVEKO % P 1- 00 !n 00 C-4 Do go 740 00 V) t AIR f-] LOT 20 CONDITIONER LOT 21 PAD BLOCK IS BLOCK 18 �0.4 —X x—X— X—X —X FOUND I/Z" IRON PIK -UL% 0.71� 140 IDCNTIrICAT#Om 10'DRAINAGE AND UTILITY CASEMENT F(RIND 1/2-IRON PIPE NO IDE97IFICA710M IRS LOT 5 N 07*18'01" W 80.70' (MEASURED) LOT 6 BLOCK 18 N 07'16*02" W 80-65- (PLAT) BLOCK 18 -WOTES: LEGEND: R = RADIUS X FENCE L . LENGTH CONCRETE NOTM E RE%ASIONS 1. BEARINGS ARE BASE0 ON THE BEARING Qr ALONG THE NORT9MY BOUNDARY LINE OF SU0JLCT PARCEL. 2. By GRAPHIC PLOTIINQ ONLY THE CAPTIONED LANDS LIE WITION FI.n0D ZONC x DATE DESCRIPTION MAP MATED APRIL 17, 1989. COMMUNHY NIJMSLF?-1-2bU6jJA&r.L NATIONAL FLOOD INSURANCE I AN 514OWN ON THE 3. THIS SU Y REFLECTS ALL EASEMENT!, & RIGHTS 01' WAY AS PER RIE�ORDED PLAT &/OR TITLE COMMITMENT IF SUPPLIED. UNLESS OTHERWISE SfATCO. NO OTHER TITLE VERIFICATION HAS BEEN PERfORMED BY THE UNDERSIGNED '*7HCRJlT IWORtIONAL S:--NATURE AND CMQOqqFn CITY OF ATLANTIC BEACH OWNER / BUILDER AFFIDAVIT 9 1. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING" REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7),FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY,TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE-OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF $25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE, THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE, WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. 11. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE, THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. 111. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO. 455-228(l). AN"OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY "CERTIFICATE OF COMPETENCY" OR THE FLORIDA "CONTRACTORS CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. TELEPHONE THE BUILDING DEPARTMENT(247-5826) IF IN DOUBT. V.ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. LA 1:� I 5(-,� Cvo , C(H(,rl�;e.- ADDRESS PHONE NUMBER Gc&�u PRINT NAME (-A-h)� A�) SIGNA1 URE DATE Beforemethis clayofsa";,7— _,./b in the county of Duval,State of Florida,has personallylbppeared herin by himself herself an affirms that all statements and declarations are true and accurate. Notary Public at Large,State of Co of 0 P;', ally Kno ic W rpA 4 E)(p Feb ary 1412 'te R.. U S p ubVtc kuj in d e hru FJBLDG/Owner-Buildler Affadavit;REVISED: 4/16/2009 BuILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax(904)247-5845 ilo— Job Address: 452 Sargo Rd Permit Number: UgalDescription31-1638-2S-29E R/P PT OF ROYAL PALMS UNIT 2 Parcel# 171539-0000 P'loor Area of Sq.Ft. Sq.Ft Valuation of Work$ 1000.00 _Proposed Work heated/cooled non-heated/cooled 128 Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of exi�ting/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system instatted? (Circle one): Yes No N/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed: Addition of 16'x8' Shed Property Owner Information: Name: Tammi Gaskell Address: 452 Sargo Rd City Atlantic Beach State FL Zip 32233 Phone 42 E-Mail or Fax#(Optional) I U Contractor Information: Company Name: Owner to build Qualifying Agent Address: city State Zip Office Phone Job Site/Contact Number Fax State Certification/Registration Architect Name&Phone# Engineer's Name&Phone Fee Simple Title Holder Name and Address 0 Avk IftyL Bonding Company Name and Address 11 —1 Mortgage Lender Name and Address %ff vow MW qw ,e hT A"q; jWWV I r" t , MrF57s"" inglon m#tioninihsj�hdicqoNn This permit becomes null b do a$*Wer e, ers, ECTION COMMENCEMENT MAY LT I Y UR PAYI 4�_� ENf S TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FAANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby ceqt&that I have read and examined this.applicafion and know the same to be true and correct. Allprovisions oflaws and ordinances governing this work will be co�nplied with whether specifled herein or not. ne granting of a permit does not presume to give authority to violate or cancel the provisions ofany otherfederal,state,or local law regulating construction or the pe?formance ofconstruction. Signature of Owner- Signature of Contractor Print Name Print Name ....................... ..........11................................... ,%�om subscribgfrbe ore me biffi- Sgs 20 REVIE*" f V.kno ITY OVA= —.20 RLEY L GRAHAM C EIC 1 1 60 SEE PERMITS FOR ADDITIONAL NotarylrubfR_ EXPIRES:Febwary 14,2 AND CON FIONS. Rondm ThtuN&M Public Underwr#m RE004MM114% DA��REVIEWED BY: 26.10 CITY OF ATLANTIC BEACH sr) 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 10-00001132 Date 9/22/10 Property Address . . . . . . 452 SARGO RD Application type description SHED PERMIT Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc new shed ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ WALLACE-GASKELL OWNER 452 SARGO ROAD ATLANTIC BEACH FL 32233 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 55 . 00 Plan Check Fee 27 . 50 Issue Date . . . . Valuation . . . . 1000 Expiration Date . . 3/21/11 ---------------------------------------------------------------------------- Special Notes and Comments *2007 FLORIDA BUILDING CODE W/2009 REVISIONS NATIONALELECTRIC CODE *CALL FOR FINAL INSPECTION WHEN SHED COMPLETE AND ANCHORED TO MEET 120MPH WIND LOAD. Shed cannot be in drainage easement . Must be at least 5 feet from property line. Roll off container company must be on City approved list and container cannot be placed on City right-of-way. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 55 . 00 55 . 00 . 00 . 00 Plan Check Total 27 . 50 27 . 50 . 00 . 00 Grand Total 82 . 50 82 . 50 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, ctTY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF /*4wae Te4d - 574U�e4 SW SEMINOLE ROAD ATLANTIC REACH,FWRIDA.12233-5444 TELEII IONE.(9041 247-5X(X1 FAX("4)247-90.4 NOTICE TO: Water Department FROM: Building Department DATE: Please be advised that the final building inspection has been completed on each of the following addresses and construction water is no longer needed: Permit Number Address X #157 %�7 Sincerely, Building Department ENERGY GUIDE For detailed information of the EPI rating number or for any ITEM listed, ask your Builder for E rP1 DCA Form 60OA-93 go .70% Or Form 60OB-93 excellent good acceptable 0 10 20 30 40 50 60 70 80 90 100 The maximum allowable EPI is 100. The lower the EPI the more efficient the home. ITEM HOME VALUE Low Efficiency High Efficiency WINDOWS............................................. DBLCLR SINGLCLR DBL TINT INSULATION ......................................... UNDRATC R30 Ceiling R-Value.......................... KNEE R19 R-10 R-30 Wall R-Value ..........­...... 2X4WDFR R11 A-0 R-7 I I --- I I I Floor R-Value.......................... PERIM.,- R-0 I R-0 I R-19 AIR CONDITIONER............................... SEER/EER ....................................... 10. 0 10.0 SEER 17.0 9.7 EER 16.0 HEATING SYSTEM ............................... Electric COP/HSPF................... 7. 00 6.8 HSPF 12.0 Gas AFUE ............................. .78 ALFUE .90 T— WATER HEATER .................................. Electric EF .................................. ELECT. .91 .88 .96 Gas EF .................................. .54 .90 Solar EF .................................. .40 .80 OTHER FEATURES .............................. ........................................................... ........................................................... I certify that these energy saving features required for the Florida Energy Code have been installed in this house. Builder Address: MASTER DUPLEX Signature:DEAN RUSSELL Date:2j/17/9 3 ATLANTIC BEACH City/Zip Florida Energy Code for Building Construction-1993 Florida Department of Community Ajr,-:� Department of Community Affairs- FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION TORM WOA-93 Residential Component Prescriptive Method A NORTH 1 2(�)I PROJECTNAME: -BUILDEW-De-ax, Kk.4-vull 0, AND ADDRESS: PERMITTING CLIMATE OFFICE: ZONE: I [1 2 03 R1 OWNER: PEIMITNO.J JURISDICTION NO.: Pies"Print CK .1. New construction or addition 2. Single-family detached or Multifamily attached 2. Ca L�I:J I 3. If Multlfamlly--No.of units covered by this submission 3. a 4. If Multifamily, Is this a worst case(yes/no) 4. tj.es 5. Conditioned floor area (sq. ft.) .5. 17 - 6. Predominant eave overhang (ft.) 6. I- S 7. Porch overhang length (ft.) 7. 8. Glass area and type: Single Pane Double Pane a. Clear glass 8a. sq.ft. /03 sq.ft. b. Tint,film or solar screen 8b. sq. ft. -sq.ft. 9. Floor type and Insulation: a. Slab on grade (R-'value +perimeter) 9a. R= 35; .1.ft. b. Wood, raised (R-value + sq.ft.) 9b. R= -sq.ft. c. Concrete, raised (R-value) 9c. R= _sq. ft. 10. Net Wall type area and Insulation: a. Exterior: 1. Concrete (Insulation R-value) 10a-1 R= sq.it. 2. Wood frame (Insulation R-value) 10a-2 R= I I qQ sq.ft. 3. Steel (Insulation R-value) 10a-3 R= sq.ft. 4. Log (insulation R-value) 10a-4 R= sq. ft. b. Adjacent: 1. Concrete (insulation R-value) 10b-1 R= sq. ft. 2. Wood frame (Insulation R-value) I Ob-2 R= sq.ft. 3. Steel (Insulation R-value) 10b-3 R= sq. ft. 4. Log (Insulation R-value) 10b-4 R= sq. ft. 11. Ceiling type area and Insulation: a. Under attic(Insulation R-value) 11a. R= 3o I I sq.ft. b. Single assembly(insulation R-value) 11b. R=. sq.ft. 12. Air distribution systems a. Ducts (Insulation +Location) 12a. R= (concl nd. uncond, b. Air Handler( Insulation + Location) 12b. R= (cond S9. 13. Cooling system (Types:central-split,central-single pkg.,room unit,PTAC.,none) 13. Type: ape nfr-&/--,n SEER/EER/COP: /p, p 14. Heating system: 14. Type: 1-%,oAJ �2 1:,*2 (Types:heat pump,elec.strip,nat.gas,L.P.gas,room or PTAC,none) HSPF/COP/AFIIIf: 0,ol 15. Hot water system: 15. Type: elee-frs'e (Types:elec.,natural gas,solar.L.P.gas,none) EF: 16. Hot Water Credits: a. Heat Recovery(HR) 16a. b. Dedicated Heat Pump(DHP) 16a. 17. Infiltration practice: 1, 2 or 3 17. 18. HVAC Credits(Type in Loner designation:CF-Ceiling Fan,CV-Cross vent, 18. HF-Whole house fan,RB-Affic radiant barrier,MZ-Multizone) 19. EPI(must not exceed 100 points) 119. a.Total As-Built points EPI =Total As-Suift point X100 19a. V50 Q b.Total Base points I Total Be"points L 19b. .2,1590 I hereby comy that the plant and specilicalions covered by the calculation are in cornpliance voith lhe Review ol plans and specifications covered by this calculation indicates compliance vAlh Florida Enorgy Code. Ills Florida Energ Belot I OdkV Ilbeinspected 'c'io ' ' -17!!%!:� "ion 5;;;CF�Stod PREPARED BY. DATE: fw compliance In h .1 I In' I hereby cenit filsbuildings a Eneclly Code, BUILDING OFFICIAL: OWNER AGENT: DATE: DATE: �Deparlment of Community Affairs- FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTIO FOA960OA-93 Residential Component Prescriptive Method A NORTH 1 2& 1. PROJECTNAME: BUILDER &-cLn AND ADDRESS: PERMITTING CLIMATE OFFICE: c,L, ZONE: 102113 )4 OWNER: PERMIT N0,J 11RISDICTION NO.: I -R] Please Print CK Now construction or addition 2. Single,famlly detached or Multifamily attached 2. +.1 3. If Multlfamlly-No.of units covered by this submission 3. 4. If Multifamily,Is this a worst case(yes/no) 4. 5. Conditioned floor area (sq. ft.) -5. il 1. 6. Predominant eave overhang (ft.) 6. I- S 7. Porch overhang length (ft.) 7. 8. Glass area and type: Single Pane Double Pane a. Clear glass ea. sq.ft. /03 sq.ft. b. Tint, film or solar screen 8b. sq. ft. _sq.ft. 9. Floor type and Insulation: a. Slab on grade (R-'value +perimeter) 9a. R= .1.ft. b. Wood, raised (R-value +sq.ft.) 9b. R= _sq.ft. c. Concrete, raised (R-value) 9c. R= _sq. ft. 10. Net Wall type area and Insulation: a. Exterior: 1. Concrete (insulation R-value) 10a-1 R= sq.ft. 2. Wood frame (Insulation R-value) 10a-2 R= 11 q4? I sq.ft. 3. Steel (Insulation R-value) 10a-3 R= sq.ft. 4. Log (insulation R-value) 10a-4 R= sq.ft. b. Adjacent: 1. Concrete (Insulation R-value) 10b-1 R= sq. ft. 2. Wood frame (insulation R-value) 10b-2 R= sq.ft. 3. Steel (Insulation R-value) 1 Ob-3 R= sq.ft. 4. Log (Insulation R-value) I Ob-4 R= sq. ft. 11. Ceiling type area and Insulation: a. Under attic (insulation R-value) 11a. R= 3o 1111 sq.ft. b. Single assembly(Insulation R-value) 11b. R=._ _sq. ft. 12. Air distribution systems a. Ducts (Insulation + Location) 12a. R= (cond b. Air Handler( Insulation + Location) 12b. R= q. Q ,_jcond9 13. Cooling system (Types:central-split,central-single pkg.,room unit,PTAC.,none) 13. Type: Per)fraJ-"n1'4 SEER/EER/COP: '/p, p 14. Heating system: 14. Type: �2,'-14 4Q (Types:heat pump,elec.strip,nal.gas,L.P.gas,room or PTAC,none) I-ISPFICOPIAFUE�. ),Of 15. Hot water system: 15. Type: elecfeo'c (Types:elec.,natural gas,solar,L.P.gas,none) EF: 16. Hot Water Credits: a. Heat Recovery(HR) 16a. b. Dedicated Heat Pump(DHP) 16a. 17. Infiltration practice: 1, 2 or 3 17. 18. HVAC Credits(Type in Letter designation:CF-Ceiling Fan,CV-Cross vent, is. HF-Whole house fan,RB-Aftic radiant barrier,MZ-Multizone) 19. EPI (must not exceed 100 points) 119. a.Total As-Built points EPI =Total'ks-lauiK points x 100 198. b.Total Base points Total Be"po.nis 19b. 211590 I hereby cartily that the plans and specil"ions covered by the calculation are in compliance with the Review of plans and specifications covered by this calculation indicates co"Pliance with Florida Energy Code-, the Florida Energy uctpf�lWeted.this building vAll be inspected PREPARED BY DATE: ;2 b for corrolanco In a=- "o =ion S. I hereby certify'Ll this u' ingis coff h F"aErorgy Code. WILDING OFF1 yonce whh I CIAL: OWNER AGENT: DATE: :ATE: ADDITIONAL TABLES CLIMATE ZONES 1 26 K-118 HftATiNG CREDIT MULTIPLIERS(HCM) SYSTEM TYPE HEATING CREDIT MULTIPLIERS(HCM) Attic Radiant Barrier HCM .98 -- Multizone HCM .90 Natural Gas AFUE .68-.72 .73-.77 .78-.82 8&.92 .93&Up HCM .59 .55 .51 .45 .43 LP Gas HCM iL� .74 .69 .65--. .61 .59 SA-19 COOLING CREDIT MULTIPLIERS CCMJ SYSTEM TYPE COOLING CREDIT MULTIPLIERS(CCLq Ceiling Fans .86* Cross Ventilation .90* Whole House Fan .90* Credit may be taken for only Multizone .95 one of these system types concurrently. Attic Radiant Barrier .95 6A-20 HOT WATER CREDIT MULTIPLIERS(HWCM) SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS(HWC Heat Recovery Unit With Air Conditioner Heat Pump HWCM .62 .58 Dedicated Heat Pump EF 2.0-2.49 2.5-2.99 3.0-3.49 -3.-5&Up HWCM .44 �5 .29 .25 A HWM MUST BE USED IN�dNJILINCTION NTH ALL HKM.SEE TABLE 6A-9.EF MEANS ENERGY FACTOR. 6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK PRACTICE 11 606.1 COMPLY WITH ALL INFILTRATION PRESCRIPTIVES. I-- Windows 606.1 Maximum of 0.34.CFM per linear toot of operable sash crack(includes sliding glass doors). L" Exterior&Adjacent Doors 606.1 Maximum of 0.5 CFM per sq.ft.of door area;solid core,wood panel,insulated or qlass doors only, L".1 E xlehor Joints&Cracks 606.1 To be caulked,clasketed,weatherstripped or otherwise sealed. PRACTICE#2 606.1 COMPLY WITH#1 AND THE FOLLOWING: Exterior Walls and Floors Top plate penetrations sealed. Infiltration barder installed. Sole plate/floor joint caulked or sealed. Exlerior Walls&Ceilings Penetrations,joints and cracks on interior surface caulked,sealed or gasketed. Ductwork Ductwork in unconditioned space must be sealed. Fireplaces Equipped with outside combustion air,doors,and flue dampers. ExhaustFans Equipped with dampers. Combustion devices see 606.1.A.2 Combustion Healing Combustion space and water heating systems provided with outside combustion air, except dir vent appliances PRACTICE#3 606.1 COMPLY WITH PRACTICES#1 AND#2 AND THE FOLLOWING: Ceilings Infiltration barrier installed. Interior Walls Top penetrations sealed or joints&cracks on interior walls caulked,sealed or gasketed. Recessed Lights Sealed from conditioned&insulated from ventilated allic spaces. Ductwork All ductwork located in conclitioned space. Combustion Apoiances Be in unconditioned space(except direct vent),draw air from unconditioned space,exhaust to outside. Cooking appliances shall be dampered and use intermittent ignition. 6A-22 OTHER PRESCRIPTIVE MEASURES(must be met or exce4eded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply---with-efficiency requ Fre-ments in Table 6-11.Switch or clearly marked circuit breaker(electdc) or cutoff(gas)must be provided.Extemal or built-in heat trap required Swimming Pools&Spas --T-1 2-1 Spas & heated pools must have covers (except solar heated). Non-oommercial pools must have a pump timer.,Gas spa&pool heaters must have a minimum thermal efficiency of 78%. Shower Fe-ads 612.1 Water flow must be restricted to no more than 3 gallons per Fi-nute at 80 P-S-1G. HVAC Duct ConstruCb-on ---TO-1 All ducts,fillings,mechanical equipment and plenum Chambers shall be mechanically attacFi-ed, Insulation&Installaton sealed,in sulated,and installed in accordance with the criteda of Section 610.Duct in unconditioned space must be insulated to a minimum of R-6.Air handlers shall not be installed in attics unless in mechanical closet. HVAC Controls 607.1 Separate readily accessible ma-nual or aut6-maticthermo slat for each system. Insulation 1604.1.,_502.11 Ceilings-Min.R-19.Common wall s-Frame R-11 or-M:i H-300tn Sides.Common ceilingl floorsR-11. WINTER CALCULATIONS AS-BLT. WTR. GLASS BASE WINTER ORIENT. GLASS WOF GLASS ORNT. AREA WPM BASE PTS AREA DBLCLR ' (9B) WTR. PTS N -10. 6 N 7. 3 NE -10. 6 NE 4 . 6 E 55 -10. 6 -583 E 55 -9. 2 0.77 -390 SE -10. 6 SE -22 .7 S 22 -10. 6 -233 S 22 -28.4 0.94 -587 SW -10. 6 SW -22 .7 W 26 -10. 6 -276 W 26 -9. 2 0. 77 -184 NW -10. 6 NW 4 . 6 H -10. 6 H -57. 7 1. 00 COND TOTAL BASE BASE ADJUSTED AS BUILT FLOOR GLASS ADJ GLASS GLASS GLASS AREA AREA FACTOR SBTOTAL BASE WP SUBTOTAL . 15 1163 103 1. 69 -1092 -1850 -1161 AS BLT COMP. WTR PT BASE COMP. MULT. WINTER DESC. AREA MULT. WTR.PTS. DESC. AREA (9C-9G) POINTS LS EXT. 991 2 . 2 2180 ADJ. 3 . 6 2X4WDFR Rll 991 3 .7 3667 DOORS DOORS EXT. 44 12 . 3 541 EXT WD 44 12 . 3 541 ADJ. 11. 5 ADJ WD 11.5 CEILING CEILINGS UN.ATC. 1163 1.2 1396 UNDRATC R30 1179 1. 2 1415 SGL.AS KNEE R19 54 2 . 0 108 FLOOR FLOOR SLAB 135 8.9 1202 PERIM. R-0 135 18.8 2538 RAISED 0.96 INFIL. 1163 7.4 8606 # 2 1163 7.4 8606 L OMP j i� 6 T6�i" *C­ : * *B*AS WINTE PO TS TOT L AS B ILT WINTER POINTS TOTAL 12075 TOTAL 15714 HEATING TOTAL BASE AS BLT DM HSM HCM AS BLT SYSTEM BSC HSM BS PTS HTG P WTR PTS ' (9H) (91) (9J) HTG. PTS. 0.55 12075 6641 15714 1. 10 0. 48 1. 00 8366 TOTAL BASE BASE BASE TOTAL AS-BLT AS-BLT AS-BL TOTAL COOLING HEATIN HT WTR BASE COOLING HEATING HT WT AS-BLT POINTS POINTS POINTS POINTS POINTS POINTS POINT POINTS 6529 6641 11409 24580 5107 8366 11034 24507 PREPARED BY ENERGY DESIGN SYSTEMS 904-287-5339 EPI= 99.70% ENERGY CODE SECTION 6 NORTH ZONE 1, 2 , 3 600-93 DEAN RUSSELL SUMMER CALCULATIONS MASTER DUPLEX AS BLT SMR. GLASS BASE SUMMER GLS SOF GLASS ORNT. AREA SPM BASE PTS ORIENT. AREA DBLCLR 1 (9B) SMR, PTS N 65.8 N. 38.3 NE 65.8 NE 57.7 E 55 65.8 3619 E 55 79.7 4033 SE 65.8 SE 79. 1 S 22 65.8 1448 S 22 66.2 0.86 1253 SW 65. 8 sw 79. 1 W 26 65.8 1711 W 26 79.7 0.92 1906 Nw 65.8 NW 57.7 H 65.8 H 267. 0 1. 00 COND TOTAL BASE BASE ADJUSTED AS BUILT FLOOR GLASS ADJ GLASS GLASS GLASS AREA AREA FACTOR SBTOTAL BASE SP SUBTOTAL . 15 1163 103 1. 69 6778 11480 7192 AS BIT COMP. SUM PT BASE COMP. MULT. SUMMER DESC. AREA MULT. SMR.PTS. DESC. AREA (9C-9G) POINTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WALL WALLS EXT. 991 0.90 892 1685 ADJ. 0.70 2X4WDFR Rll 991 1.7 DOORS DOORS 44 6. 1 268 EXT. 44 6. 10 268 EXT WD 2 .4 ADJ. 2 .40 ADJ WD CEILINGS CEILINGS 0. 6 707 UN.ATC. 1163 0.60 698 UNDRATC R30 1179 SGL.AS 0. 60 KNEE R19 54 1. 1 59 FLOOR FLOOR SLAB 135 -37 . 00 -4995 PERIM. R-0 135 -41.2 -5562 RAISED -3 .99 INFIL. 1163 8. 00 9304 # 2 1163 8 . 0 9304 . . . . . . . . . . . . . . . . . . . . . . . . . . . TOTAL COMPONENT BA E oil�i S. . . . . . .T 6�A L.i S i6 I UMMER POINTS TOTAL 17647 TOTAL 13654 COOLING TOTAL BASE AS BLT DM cSM CcM AS BLT SYSTEM BSC CSM BS PTS CLG PT SMR PTS 1 (9H) (9K) (9L) CLG PTS 0. 37 17647 6529 13654 1. 10 0. 34 1. 00 5107 HOT WTR NBR BASE BASE AS BLT NBR HWM HWCM AS BLT SYSTEM BDRMS HWM HW PTS HW DES BDRMS (9m) (9N) HW PTS 3 3803 11409 ELECT. .91 3 3678 1.00 11034