Permits Folder 393 Ahern Street4 w
. ~
PERMIT WORKSHEET
Job Address:
Property Owner:
Contractor:
Permit #:
Certificate of Occupancy
X93 ~~~ Sr.
~X~i o b/11~f~1~ I~
Type Work:
Phone #
Phone #
Date Issued:
~~
~~ ~ (og~P
1l
Tree Permit# fJ~'1 ~~//v~JL. ~~/V~~' ~~~' Y~r'v~
Foundation Permit #
Demolition Permit # W ~ ~,~ [,~
^
BUILDING
Footing
-Slab
Tie Beam
Lintel
Nailing/
Sheathin
Framing
Insulation
Building
Final
Drainage Inspection:
Pool Permit #
ELECTRIC #
Tem .Power #
JEA Release
Date
Temp. Power
Letter Recd.
Temp Pole #
JEA Release
Date
Rough
JEA Release
Date
Electric
Final
JEA Release
Date
Inspections: Steel
Elec./Grounding
Roofing Permit #
Inspec#: Nailing/Sheathing
Fire Inspection:
Failed Inspections:
Underslab
Water/
Sewer
Rough/
Top out
Plumbing
Final
Final
Final
Final
Date Paid: ~`^~
CITY OF ATLANTIC BEACH
800 SENIINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5826
Application Number 06-00034080 Date 11/28/06
Property Address 393 AHERN ST
Application type description RESIDENTIAL ADD/RENOVATE/ALTER
Property Zoning TO BE UPDATED
Application valuation 15400
------------------------
Application desc ----------- -------------------------------- ---------
INTERIOR REMODEL
------------------------
-----------
--------------------------------
---------
Owner Contractor
-------------------
ELIA, LAUREN ----- ------------------------
EXTRAORDINAIRE HOME IMP
INC.
393 AHERN STREET 5141 SIESTA DEL RIO DR.
ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32258
(904) 260-6866
------------------------
Permit -----------
BUILDING --------------------------------
PERMIT ---------
Additional desc .
Permit Fee 110.00 Plan Check Fee 55.00
Issue Date Valuation 15400
Expiration Date 5/27/07
-----------------------
Fee summary
----------------- ------------
Charged
---------- --------------------------------
Paid Credited Due
---------- ---------- ------- ---------
---
Permit Fee Total 110.00 110.00 .00 .00
Plan Check Total 55.00 55.00 .00 .00
Grand Total 165.00 165.00 .00 .00
PERMTI' IS APPROVED ONLY IN ACCORDANCE ®VITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUII,DING CODES.
Doc # 2006408997,_ OR BK 13662.. Page 21:45,
Tax Folio Number: 1.69917-0105 and 169727-0000 Number Pages. 2
Filed & Recocded'11l28J2006 at 1:1:34AM,
State of Florida JIM FULLER. CLERK CIRCUIT C6URT DUVAL COUNTY.
County of Duval RECORDING $18.S0 -
Fite Number. 5029.009
NOTICE OF COMMENCEMENT
The undersigned hereby gives notice that improvement will be made to certain real property, and, in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement,
1. Description of Property: See Attached Exhibit "A"
a. Property Address: 391, 393, 395, 397, 399 Ahern Street, Atlantic Beach, FL 32233
309, 31 I, 313, 315, 317 7th Street, Atlantic Beach, FL 32233
2. General Description of Improvements: The improvements on the property include reroofing, re-flooring, stucco
exterior, painting, remodel kitchen, install new cabinets and countertops, install new bathroom fixtures and install
Q new windows.
j ~'* 3. Owner Information:
a. Name and Address: Atlantic Beach Condominiams, LLC
9857 St. Augustine Road, Ste. 5
Jacksonville, FL 32257
b. Interest in property: Fee Simple
c. Names and address of fee simple title holder (if other than owner):
Atlantic Beach Condominiums, LLC
9857 St. Augustine Road, Ste. 5
Jacksonville, FL 32257
4. Contractor. Extraordinarre Home Improvements, Ina
5141 Siesta Del Rio Drive
Jacksonville, FL 32258
5. Surety: NIA
6. Lender: CenterBank of Jacksonville, N.A., Attn: Campbell Patterson
1325 Hendricks Avenue, Jacksonville, Florida 32207
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served
as provided by Section 713.I3(I) (a)7., Florida Statutes.
8. In addition to himself, Owner designates the following persons to receive a copy of the Lienor's Notice as
provided in Section 713.13(I)(b), Florida Statutes: CenterBank of Jacksonville, H.A., Attn: Campbell Patterson
1325 Hendricks Avenue, Jacksonville, Florida 32207
9. Expiration date of Notice of Commencement (the expiration date is 1 year from date of recording unless a
diffe date is specified}.
ATLAN B CH CONDO S, LLC
Print Name: vl. ~'"'~ (~,~~)
Print
Marc Mated El Hassan
Its: Managing Member
Sworn W and subscribed before me this ~~~'day of November, 2006 by Marc Majed El Hassan, Managing Member of
Atlantic Beach Condominiums, LLC, who is~crsonally known to me or who did provide
as identification.
~.
---..~ , r
`r
~ `~~ ~. STEPHANIE D. 9UMANGLAG
My Commission Expires: l'a5"~' ~ (o FcZ0~9 .+! - NoteryFubfic-Sta~afFtotkte
•=NNy Cotrm~On Exp6esAtg 1$.2009
'~' Comtt~sion # DD48251i
~''~•°„; t' •`'+ Bonded BY NaUonel Ntllary Aeen.
rj,=1~y;~.fJ~,
\~: ~ s s CITY OF ATLANTIC BEACH
:~
J PLAN REVIEW SHEET
~r
~f Building Department Public Works & Public Utilities De artments
~"J'tisr 800 Seminole Road 1200 Sandpiper Lane p
Atlantic Beach, Florida 32233 Atlantic Beach, Florida 32233
(904)247-5800 (904)247-5834
(904)247-5845 Fax (904)247-5843 Fax
S. Doerr
R. Carper
D. Kaluzniak
Public Safety
PLAN REVIEW COMMENTS
Permit Application # O~p ~ `fQd'
Property Address ~ 93 ~n ~,e77 c}~
Applicant: /~. ~A ~i ~ .J ~7~Gt. ~7~N1 GJ~'T~~l Der~~-T~`T7~~
Project: /~ T~iei~0~ ~~rn p o~~L
This permit application has been:
Approved as noted by the ~(?jG~ Department.
Final application approval must come from the Building Department.
~ Reviewed and the following items need attention:
Please re-submit 2-copies of all revisions. Please re-submit your
revisions to the De artment re uestin them.
Building Dept, Public Works and Utility information at top of page,
failure to notify the cor ect department may delay your permit from
bein issued.
Reviewed By: Date: ~~ _% ~~
Date Contractor Notified:
J' x)1'1 r~y\ ~~
~~
~. ~_~~
~ ~ ~/'~
ri J~/
X93
dob Address:
Owner of Property: R{ lu vt {-i C
CITY t~F ATLANTIC BEACI~I
BUILDING PEItMfIT` APPLICATIOI~T
(Interior Remodel}
Date: ~ lJ ° ~ ( ` ~ `a
P/I YtJ LVt~C L". l.-~
Address: q~~7- ~ ~~. ~u e~ c.ts~lb^. z~ 1'~_~~Q 1C~~ v2 ~l ~j ~ Telephone: -I<~'~" ~~C~~' ~~ ~ ~__
Legal Description: ~~B,lack Number; nZ Lot Number: ~_ Zoning District:
Contractor: ; 1? i 11 ,,;~ State License Number: C ~ 1 ~:~ ~ ~
__. ~ 'Lla l4 t ~ C~k~~; ~~.. ~
Cortrar2or's Address: ~ ~ ~' ~ ~tvc~0. l-let ~ j~ 1.11'1 (~C~. _ . _~C~~(~ ~ F~" 3 ~ ~ ~R
Telephone:
Rey '" ~~ " ~c ~ ~ ~ Fax: ~-
Present use of land or building(s):
Valuation or proposed construction:
Naw electrical or incnr~easepin service? ixta,~^~r~ ~ ~ttc~ `'~c'~'P,~,.dd pltunbing #'ixhues?
.add fireplace? ! ~V , !~.
Is approval of Homeowner's Association or other private entity required? !~~ If yes, please submit with this
application.
Procedure: Tn order to expedite issuance of permits, please follow all steps and provide all information as aapr~riate.
Inc®mplete applications may resatlt in delay itt issuance of permit.
Pizase submit Building Permit ,4pplication, Bnett~ Code Fo:tns, I`oticc of Commencement, OwnerlContractor Affidavit if owner is coniracror,
a:-d two (2) complete sets of construction plans to the Building l7epartment, which is located at the Atlantic Beach City Elan, flo0 Seminole
I`~oad, Atlantic Beach, FL 32233 Tetapteone: (904) 247-582ti
In addition to construction and engineering deieil, plans must contain the following information as appropriate fo- the type of work being
performed. Scale of drawings should be sufficient to depict alt rsguired information in a clear sad legible mmnner.
81?{l Seminole Road - Atlantic Beach. Florida 32233-545
Telephone: (90d) Zd7-5800 • Fax: (904) 247-g84S - bttp:/Iwww.ci.atiantic-beach.fl.us
Page 2
Revised 1104
t
Add heatinglair conditioning? ~~ [QC's'.
I hcs;,'tyy certifi that a!t information appiigtign t. (~
Signatory of Propern+ Owner: Datr: ~ `-' ~ ~ ~ Q
i hereby certify' that 1 have read and examined this apptlcation and knav,• the same tp be true and cerreet. ,111 provisions of the laws and
ordinances governing this type of work will be complied with, whether ~peciiied herein or re ?'.:e ~,4^ti^.s of u p;.~ n;t due; not presume tc
live authority to violate or cancel the previsions of any federal, state or Iocai rules, regulations, urdinar;ces, nr iaµ , in any nnanrcr, including the
governing oz construction or the performance of construction oSthe property. 1 understand that the issuanr:e o: thW permit is contingent upon the
a`_k~.•e information being true and tan t pl sand portin • to have been or shall be i=rvvide1d as, rewired. ("~
Sigrsatt:reefCotttractor: pave: / O .-- /~~ `•'
Ad,9ress and contact information of person to receive all correspondence regarding this aplali;;atia:: (plf~•:zse pri,~t}.
Name:
T~~~lailirtb ~.ddress: _ `'(~K5 ! - ~ ~'t•. ~ t
Telephone: ~t') - ~(~" ~C ~ 1 Fax;
~.s ~~ r~~~rl~R:
c,worn to and subscribed before me this `~~ day of ~~-~h~ , 2f1 a ~p,
State of Florida C u v
,PF ~ F q~ STEPHANIE D. BUAMtiGU1G ~'\ 1
~, ; Notary PubNc • Stets of Florida Notary's Signature:
?'+r ~NIyC~pYeaAtpl&2009 y,
~l~l62S11 Personally knov t
~~''£OP.. ~~ Bondett By Natbnai NotaryAsMt. Produced idcntif+caiion
Type of identifcation produced
r~S'FrJ C4i'QTRACTOR:
S~~~o:n. to and subscribed be:fare me this
State or Florida, County of Duval
.~rii~~i
~~~~~~., STEPHANIE D. BUtiAANGtAG
;':°~~aY pue°c~': N018ry PItl311C - $tett Ol F10rlda
• ` ' • ~Ay Commission Expires Alp 18, 2009
~`~ Cortar>ission * DD482511
•~''~ °~ ;;°a'`• Bonded By Nalfonal Nohry Assn.
Notary's Signature:
Personally lrno>S~ra
^ Produced identification
Type of identification produced
840 Seminole Road • Atiarltic Seach, Florida X2:33-5445
Telephone: (904) ?A7-5804 • Fax: (904) 247-5845 - http:llwvwrv.ci.attantie-bcucla.fl.~ts
('~r day of (J~,{l~Y~d _~, ''0 d b .
1'.II~e 3 Revised 1/04
3'~~' ~t ~afYf4?yNt1~ ~. ,.
y Y
.~-.~arq.,aeww». ..
,.+. -~-=1 -fir > rf 1 - ~ r ..
.
~ ~ ~ Vi
y
{~ `
~ - .. - wit
4 f ~ i{` '~f
' ..
t t
.:.. ~. :~
1
~' v+
q ~ ~ }
`~ ~ ~
N~ ~
. {.w ~~ _
q
' e
~~~ . ',.
t
~ E'r
~ t ~ t ~ {
F !:
.t ~t ~ q
f
f .Y.
r,
~1
,_~~ ~
~l ~~~
_ ~~ V
} ~ ( ~ ~4
,~~'~~ ~~
.?
~.~m '~~
~ w
~, ~'~ Q! r 'lv ~y
~.,+
;~ ~ ~ '
. ,~ .. .
x
~~, ~~
`v
,.
.~~..
`,.
~ ~~ _
~..._.
O
_, .- ,__.w.,-..._~ . _ ~ ~. ~ ~ ~ . .
_.
~ . , _ ;..
t{
l ~
~
)
~,,~ ..
~
,A~tt
l
~•
Eljj~ ~. ,
.. • ' ,'
MM
"
J
~~
~,~ ///
/ r
1
tF ..
~, ~ f ~,~ ~... _ ..r.-_--..~...._.--
~~ __-~--
9857 St. Augustine. Road, Suite 5 Jacksonville,. FL 32257
In regards to: Atlantic Beach Condominiums, LLC
Atlantic Beach Building Department
800 Seminole Road
Atlantic Beach, Florida 32233
Attention: Dave Hostettler
Dear Dave Hostettler:
i~rt E~r~ ~' `~'
~'t" :,i~r~f:
Per our conversation concerning the Atlantic Beach Condominiums, LLC, properties
located at 391-Ahern Street and 309-7`h Street, this letter is to inform your department of
the work to be completed at said properties, as well as, respond to comments made by S.
Makowski (see attached comment sheet).
As we have discussed, there will be no structural changes to the existing building
configurations and/or floor plans making this project a cosmetic remodel only. The
following list includes all the work that is planned for completion prior to sale of the units
as Town Homes:
1) All appliances in the kitchen area, as well as, cabinets and countertops will be
removed and replaced.
2) All sinks, toilets, bathtubs, faucets, and cabinetry in the bathrooms will be
removed and replaced. New water heaters will be installed to replace old ones.
3} All air-handlers, condensers, and duct-grills will be removed and replaced, but all
original ductwork will stay intact except for plenum box adjustments for new
handlers. Energy calculations are attached.
4) All electrical outlets and switches are to be replaced, including arc fault circuits in
all bedrooms. Living area downstairs will get additional ceiling boxes for lights
and/or existing boxes will be relocated. A new outlet will be installed on living
area stair wall for wall hung television. Garbage disposal circuit and wiring will
be installed for kitchen sink.
5) All doors and windows will be replaced following Florida Building Codes.
Product Approval sheets are attached.
6) All ceilings and walls will be textured and painted.
7) Attic separations to be upgraded to 2-hour fire rating using appropriate gypsum.
Remainder of separation walls from second story ceiling to slab, is concrete
block
~ .r _. ~.~~.~ ~~:~S.~b~-tA~1~1~k~ ~a~~~'~~' ~~bi~~,...a_5~_.r~.'.~ ~.~sE ,r 'F h., ~1. ~~'~~ _~~~,~~.-=~~'
November 7, 2006
..9857 St. Augustine Road, Suite 5
8) Smoke detectors will be installed in bedrooms and upstairs hall area and wired
together per FBC.
9) At 391-Ahern Street roof was replaced, and permit for that work is on file.
10) Carpet and the for all units will be upgraded.
11) Exterior of buildings will be done in new stucco over existing surfaces.
All the aforementioned work will be done to both buildings in every unit unless otherwise
specified. Again, there will be no structural demolition or structural additions to these
buildings. All pertinent information including product approvals for doors and windows,
energy calculations, asbestos surveys, etc., should be included with this letter.
There will also be some site improvements to the Ahern property which are being drawn
and sealed by a landscape architect and civil engineer. Those plans are being submitted
separately.
Please feel free to contact me at 904-880-4681(office) or 904-226-4477(cell) for
clarification on any issues concerning this letter or the proposed work.
Construction Manager
IGD/Atlantic Beach Condominiums, LLC
,- - ~ _
5 '1 .. r, M ~ , 1
Ica ~_~ it fr ~ ~ i ~ 'c'4 '1~1~M/~S~/~~i~_:d~~"t.-i&9~~®~i7.,u~ ~ .~~1'SiE~ .... _.,_~_ ~/Y'1..~_ l.-_~T._.,~
__--
--
~//~~a~
s-.------,~
`~ `VSI~,I/f'/ /,
~~ ~ , ~ ['LANTIC BEACH
,, ~ ~ ~. ~,s EW SHEET
J ~ i `° ~ i
~~ ~~ S ~ ~, C~l ~pt~CJ it public Works & Public Utilities Departments
` - - /~ 1200 Sandpiper Lane
da 32233 Atlantic Beach, Florida 32233
~~.,.~~ f,..,-,,~.,,, (904) 247-5834
(904)247-5845 Fax (904}247-5843 Fax
PLAN REVIEW COAZMENTS
Permit Application # ~ ID ' ~ `~~ 7 J
Property Address
~9/
Applicant:
~`~
~~
Project: f ~? ~ ~ie ~ l,t..° ,/C ~I91 o G~~. L.
This permit application has been:
Approved as noted by the --~~'~ Department.
~'~ Final application approval must come from the Building Department.
~~
j~ Reviewed and the following it ~ s need attention: - ,
/~/~ ~~ G-0~r~ 7~ ~(~~ CC n~ • ~ fL' -' C~Nbc7 l~fi S
1
2
~,
~.
V
Reviewed By: Date: / d
Date Contractor Notified: ___. ~r 1'
z~ ;~r~-~r~ TV ~ ~- ~~ ti ~ . ~'G ~~ 13
~D _ _ ~ a~~' ~`~~ ~S /~u ~ r~ Hwy ~~ ~/.S'.G . 13 //
r~ D~~s LC o- a~ 5 ~- ~ ~ I G'
,~5~ ~ ~v ~S I a,~,
!5~ ~v CoM f'° w!>/f' ~ ~ ~~ • ~• ~ ~~ is ,
f ~/~C ~~i ~~~ GII~ c1 ~/ LCs .~ "~, a~o~ :~?7 ~ brG ~'~t~ o . ~ o . /'Z B
5 ~~ z. S w uj
A
Please re-submit 2-copies of all revisions. Please re-submit your
revisions to the De artment re uestin them.
a
Building Dept, Public Works and Utility information at top of page,
failure to notify the corre department may delay your permit from
bein issued.
S. Doerr
R. Carper
D. Kafuzniak
Public Safety
.~ ~l7~
~~
~W
~~~
~~
N
~~`~
~T~ ~Nwr6.ur ~ /
APPENDIX 13-D
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 6000-04 Residential Limited Applications Prescriptive Method C NORTH 1 2 3
Small Additions, Renovations & Building Systems
Compliance with Method C of Suh-Chapter 6 of the Florida Energy Efficiency Code may be demonstrated by the use of Form 6000.04 for additions of 600 square feet or less, site-installed components of
menufaclured homes, and renovations tc single- and multiple-family residences. Altemadve methods are provided for atltllticns by use of Form 6008-04 or 600A-04.
PROJECT NAME: ' UILDER:
AND ADDRESS:- PERMITTING CLIMATE
OFFICE: ZONE: 1 ~ 2 ~ 3
OWNER: ~ ~ PERMIT NO.: JURISDICTION NO.:
SMALL AUDITIONS TO EXISTING RESIDENCES (600 square feet or less Of conditicned area)..Prescriptlve requirements in Tables 6C-1, 6C-2, and 6C-3 apply only to the components of the addition, not to
the existing hpilding. Space heating, cooling, and water heating equipment efficiency levels must he met ony when equipment is installed specifically to serve the addition or is heing installed in
conlunc6on with the addition construction, Components separating unconddionetl spaces from conditioned spaces must meet the prascdbed minimum insulation levels. RENOVATIONS (Resitlentlal
buildings undergoing renovations costing more than 30 % of the assessed value of the building). Prescriptive requirements in Tables 6C-1 antl 6C-2 appy only to the componeMS and equipment being
renovated or replacetl. MANUFACTURED HOMES AND BUILDINGS. Only site-installed components and features are covered by this lorm. BUILDING SYSTEMS. Comply when complete new system is
installed.
Please Print CK
1. Renovation, Addition, New System or Manufactured Home
2. Single-family detached orMultiple-family attached
3. If Multiple-family-No. of units covered by this submission
4. Conditioned floor area (sq. ft.)
5. Predominant eave overhang (ft.)
6. Glass type and area:
a. Clear glass
b. Tint, film or solar screen
7. Percentage of glass to floor area
8. Floor type and insulation:
a. Slab-on-grade (R-value)
b. Wood, rased (R-value)
c. Wood, common (R-value)
d. Concrete, raised (R-value)
e. Concrete, common (R-value)
9. Wall type and insulation:
a. Exterior: 1. Masonry (Insulation R-value)
2. Wood frame (Insulation R-value)
b. Ad]acent: 1. Masonry (Insulation R-value)
2. Wood frame (Insulation R-value)
c. Marriage Wails of Multlpie Units' (YesMo)
10. Ceiling type and insulation:
a. Under attic (Insulation R-value)
b. Single assembly (Insulation R-value)
17. Cooling system*
(Types: central, room unit, package terminal A.C., gas, existing, none)
12. Heating system*
(Types: heat pump, elec. strip, natural gas, LP-gas, gas h.p., room or I
existing, none)
13. Air distribution system*
a. Backflow damper or single package systems` (YeslNo)
b. DOcis on marriage walls adequately sealed` (Yes/No)
14. Hot water system:
(Types: elec., natural gas, other, existing, none)
Pertains to manufactured homes with site-installed components.
3. g.. ^
4. T`
s. ~ . 3
Single Pane Double Pane
6a. sq. ft. sq. ft.
6b. sq. ft. sq. ft.
7.
Ba R = lin. ft.
Bb. R - sq. ft.
Sc. R = sq. ft.
Sd. R = sq. ft.
Be. R = sq. ft.
9a-T R = sq. ft.
9a-2 R . sq. ft.
9b-1 R = sq. ft. I
9b-2 R = sq. ft.
9c
10a. R = sq. ft.
10b. R . sq,ft.
11. Type: ~~j' ~~
SEER/EER:
T2. Typ .
HSPF/COP/AFUE} r 1
13
13 I
14. Type:
EF:
I hereby certify that the pia~ts and specifications covered by the calculation are incompliance wdh Review of plans and specifications coveretl by this calculation indicates compliance with the Florida
the Florida Energy Cotle. (, ~ ~, r 1 1 [- Energy Code. Before construction is completed, this building wilt be inspected for compliance in
~\ l G~~t~ e ~ accordance with Section 553.908, F.S.
PREPARED BY: ~ bATE ta~,-,~"9 ',-!h.'A'
I hereby certify that this buildingg lance with the Fioritla Energy Code: UILDIND OFFICIAL:
OWNER AGENT: DATE: GATE:
FLORIDA BUILDING CODE -BUILDING 13-D.33
RIGHT-J BUILDING ANALYSIS REPORT
Entire House
Energy Design Systems Job: 10/30/06
1085 Oak Vale Rd, Jacksonville, FI 32259 Phone: 904-287-5339 Fax: 904-287-1258 Email: energydesignsystems(SJgmail.com
~ ~ ~ •
For: Typical Condo Unit,391 Ahern St.
Buildings 395 & 397, Atlantic Beach, Fl
~- • • •
Htg Clg Infiltration
Outside db ((°F) 39 92 Method Simplified
Inside db (°F) 72 72 Construction quality Average
Design TD (°F) 33 20 Fireplaces 0
Daily range - ~
Inside humidity (%) - 50
Moisture difference (gr/lb) - 65
•
Component Btuh/ftZ Btuh % of load
Walls 3.0 2745 20.3
Windows 23.9 2081 15.4
Doors 15.2 732 5.4
Ceilings 1.1 592 4.4
Floors 9.7 1666 12.3
Infiltration 37.2 5030 37.3
Ducts 642 4.8
Total 13488 100.0
windows
~ Cooling
Component Btuh/ftZ Btuh % of load
Walls 2.5 2296 15.3
Windows 72.0 6264 41.7
Doors 12.7 612 4.1
Ceilings 1.6 862 . 5.7
Floors 0.0 0 0.0
Infiltration 11.3 1524 10.1
Ducts 1366 9.1
Internal gains 2100. 14.0
Total 15023 100.0
wood°ws
Cooling at 80 %SHR = 1.5 ton Cooling air flow = 471 cfm/ton
Cooling at 70 °I° SHR = 1.7 ton Cooling at 400 cfm/ton = 1.8 ton
Overall U-Value = 0.135 Btuh/ftZ-°F
WARNING: window to floor area ratio = 8.9% -less than 10%.
,~, wr~ghtsofC Right-Suite ResidentialTM 5.0.66 RSR297a4 2008-N°v-01 12:27:20
fICCA C:\Documents and Settingslcustomer\My DocumentslWrigntsoft\D. Lee Ross "fownhouse,Ahem St.•7ypical. Page 1
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
Energy Design Systems Job: 10/30/06
1065 Oak Vale Rd, Jacksonville, FI 32259 Phone: 904-287-5339 Fax: 904267-1258 Email: energydeslgnsystems(d gmail.com
~ ~ • •
For: Typical Condo Unit,391 Ahern St.
Buildings 395 & 397, Atlantic Beach, FI
Notes:
Design Information
Weather: Jacksonville, Mayport Naval, FL , US
Winter Design Conditions Summer Design Conditions
Outside db 39 '°F
Inside db 72 °F
Design TD 33 °F
Heating Summary
Building heat loss 13488 Btuh
Ventilation air 0 cfm
Ventilation air foss 0 Btuh
Design heat load 13488 Btuh
Infiltration
Outside db 92 °F
Inside db 72 °F
Design TD 20 °F
Daily range L
Relative humidity 50
Moisture difference 65 gr/Ib
Sensible Cooling Equipment Load Sizing
Structure 15023 Btuh
Ventilation 0 Btuh
Design temperature swing 3.0' °F
Use mfg. data n
Rate/swing multiplier 0.97
Total sens. equip. load 14573 Btuh
Method Simplified
Construction quality Average
Fireplaces 0
Heating Cooling
Area (ftz) 976 976
Volume (ft') 8298 8298
Air changes/hour 1.00 0.50
Equiv. AVF (cfm) 139 69
Heating Equi pment Summary
Make
Trade
Latent Cooling Equipment Load Sizing
Internal gains 690 Btuh
Ventilation 0 Btuh
Infiltration 3040 Btuh
Total latent equip. load 3730 Btuh
Total equipment load 18303 Btuh
Cooling Equipment Summary
Make
Trade
Efficiency 0.0 HSPF Efficiency 0.0 EER
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh
Heating temp rise 0 °F Total cooling 0 Btuh
Actual heating fan 719 cfm Actual cooling fan 719 cfm
Heating air flow factor 0.053 cfm/Btuh Cooling air flow factor 0.048 cfm/Btuh
Space thermostat Load sensible heat ratio 80
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
„~ Wr~gl->t'tso-Ft Right-Suite ResidentialTM 5.0.66 RSR29764 2006-Nov-01 12:27:21
.AC+/A C:\Documents and Settingslcustomer\My Documents\Wrightsoft\D. Lee Ross Townhouse,Ahem St: Typical. Page 1
APPENDIX 13-D
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 6000-D4 Residential Limited Applications Prescriptive Method C NORTH 1 2 3
Small Additions Renovations & Building Systems
Compliance with Method C of Sub-Chapter 6 of the Florida Energy ERiciency Cade may be demonstrated by the use of Form 600C-04 for additions of 600 square feat ar less, site-instatled components or
memd~MurcA hmm~s ann renmrarinns to sinole-and muttidte-family residences. Altematlve methods are provided for additions by use of form 6006.04 or 600A•04.
PROJECT NAME: BUILDER:
AND ADDRESS: PERMITTING CLIMATE
OFFICE: ~'~ Y ZONE: 1 ~ 2 ~ 3
OWNER: ,$ PERMIT NO.: JURISDICTION NO.:
SMALL ADDITIONS TO EXISTING RESIDENCES (600 square feet or less of conditioned area). Prescriptive requirements in Tables 6c-t, 6L'-z, and tie-s appy Dory to me components or me admnon, nor to
the existing building. Space heating, cooling, and water heating equipment efficiency levels must be met only when equipment is installed specifiralty to serve the addition or is being installed in
conjunction with the addition construction. Components separating unedntlitioned spaces from conditioned spaces must meet the prescribed minimum insulation levels. RENOVATIONS (Residential
buildings undergoing renovations costing mare than 30 % of the assessed value of the building). Prescriptive requiremems in Tables 6C-1 and 6C-2 apply only to the componems and equipment being
renovated or replaced. MANUFACTURED HDMES AND eUlL01NGS. Only site-insta6etl componems and features are covered by this Corm. BUILDING SYSTEMS. Compy when complete new system Is
installed.
Please Print CK
1. Renovation, Addition, New System or Manufactured Home
2. Single-family detached or Multiple-family attached
3. If Multiple-family-No. of units covered by this submission
4. Condkioned floor area (sq. ft.)
5- Predaminant cave overhang (ft.)
6. Glass type and area:
a. Clear glass
b. Tint, film or solar screen
7. Percentage of glass to Hoar area
fi. Floor type and insulation:
a. Slab-on-grade (R-value)
b. Wood, raised (R-value)
c. Wood, common (R-value)
d. Concrete, raised (R-value)
e. Concrete, common (R-value)
9. Wall type and insulation:
a. Exterior: 1. Masonry (Insulation R-value)
2. Wood frame (Insulation R-value)
b. Adjacent: 1. Masonry {Insulation R-value)
2. Wood frame (Insulation R-value)
c. Marriage Walls of Multiple Units' (Yes/No)
10. Ceiling type and insulation:
a. Under attic (Insulation R-value)
b. Single assembly (Insulation R-value)
1i. Coolingsystem*
(Types: central, room unit, package terminal A.C., gas, existing, none)
12. Heating system*
(Types: heat pump, elec. strip, natural gas, LP-gas, gas h.p., room or PT
existing, none)
13. Air distribution system"
a. Backflow damper or single package systems" (Yes/No)
b. Ducts on marriage walls adequately sealed" (Yes/No)
14. Hot water system:
(Types: elec., natural gas, other, existing, none) ~~
'Pertains to manufactured homes with site-installed compone ts.
~OI'~,
~
2.
t
3. ~
-
5. I . ~
Single Pane Double Pane
fia. sq. ft. sq. ft.
fib. sq. ft. sq. ft.
7.
Ba R = lin. ft.
Sb. R = sq. ft.
8c. R = sq. ft
8d. R = sq. ft.
fie. R = sq. ft.
9a-1 R = sq. ft.
9a-2 R = sq, ft.
9b-1 R = sq. ft.
9b-2 R = sq. ft.
9c
10a. R = sq. ft.
10b. R = sq. ft.
11. Typa:~ ~_n~y'
SEER/EER: 13
12. Type:~Q-
C HSPF/COP/AFUE:'1
13a.
13b.
14. Type:
A
P ~:
I hereby certify that the plans and specifirations covered by the calculation are in compliance with Review of plans and specifications covered by this calculation indicates compliance with the Florida
the Florida Energy Cade. Energy Code. Before construction Is completed, this hulloing will be inspected for compliance In
~%~~-Y r ~ ~ ~ . S ` t accordance with Section 553.908, F.S.
PREPARED BY: 1 DATE: u yj ~ ~ 1~
UILDING OFFICIAL:
I hereby certify that this building I compliance with the Florida Energy Cade:
OWNER AGENT: GATE: DATE:
FLORIDA BUILDING CODE -BUILDING 13-D.33
RIGHT-J BUILDING ANALYSIS REPORT
Entire House
Energy Design Systems Job: ~oi3oios
1085 Oak Vale Rd, Jacksonville, FI 32259 Phone: 904287-5339 Fax:904287-1258 Email: energydesignsystems@gmail.com
~ • ! ~
For: Center Condo Unit,391 Ahern St.
Buildings 395 & 397, Atlantic Beach, FI
• - ~ ~ ~
Htg Clg Infiltration
Outside db ~°F) 39 92 Method Simplified
Inside db (°) 72 72 Construction quality Average
Design TD (°F) 33 20 Fireplaces 0
Daily range - L
Inside humidity (%) - 50
Moisture difference (gr/Ib) - 65
Heating
Component Btuh/ft2 Btuh % of load
Walls 3.0 1805 14.6
Windows 23.9 2416 19.5
Doors 15:2 732 5.9
Ceilings 1.1 523 4.2
Floors 15.1 1615 13.1
Infiltration 31.4 4685 37.9
Ducts 589 4.8
Total 12364 100.0
Wlndows~
Doors
Goofing
Component Btuh/ft2 Btuh °/D of Toad
Walls 2.5 1509 10.0
Windows 72.0 7272 48.3
Doors 12.7 612 4.1
Ceilings 1.6 760 5.1
Floors 0.0 0 0.0
Infiltration 9.5 1420 9.4
Ducts 1367 9.1
internal gains 2100 14.0
Total 15040 100.0
Windows
Cooling at 81 %SHR = 1.5 ton Cooling air flow = 477 cfm/ton
Cooling at 70 %SHR = 1.7 ton Cooling at 400 cfm/ton = 1.8 ton
Overall U-Value = 0.161 Btuh/ft2-°F
Data entries checked.
,~ wrightsoft Right-Suite ResidentlalT"" 5.0.86 RSR29784
2006-Nov-01 12:29:31
~ C:1Documents and Settings\customerlMy Documents\WrigMsoftlD. Lee Ross Townhouse,Ahem St.-Center U
Page 1
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
Energy Design Systems Job: 10/30/06
1085 Oak Vale Rd, Jacksonville, FI 32259 Phone: 904287-5339 Fax: 904287-1258 Email: energydesignsystems(8gmail.com
~ ~ ! •
For: Center Condo Unit,391 Ahern St.
Buildings 395 & 397, Atlantic Beach, FI
Notes:
Design Information
Weather: Jacksonville, Mayport Naval, FL , US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F
Inside db 72 °F
Design TD 33 °F
Heating Summary
Building heat loss 12364 Btuh
Ventilatlon air 0 cfm
Ventilation air loss 0 Btuh
Design heat load 12364 Btuh
Infiltration
Outside db 92 °F
Inside db 72 °F
Design TD 20 °F
Daily range L
Relative humidity 50
Moisture difference 65 gr/Ib
Sensible Cooling Equipment Load Sizing
Structure 15040 Btuh
Ventilation 0 Btuh
Design temperature swing 3:0 °F
Use mfg. data n
Rate/swing multiplier 0.97
Total sens, equip. load 14589 Btuh
Method Simplified
Construction quality Average
Fireplaces 0
Z Heating Cooling
9
Area (ft
) 12
912
Volume (ft') 7728 7728
Air changes/hour 1.00 0.50
Equiv. AVF (cfm) 129 65
Heating Equi pment Summary
Make
Trade
Latent Cooling Equipment Load Sizing
Internal gains 890 Btuh
Ventilation 0 Btuh
Infiltration 2831 Btuh
Total latent equip. load 3521 Btuh
Total equipment load 18111 Btuh
Cooling Equipment Summary
Make
Trade
Efficiency 0.0 HSPF Efficiency 0.0 EER
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh
Heating temp rise 0 °F Total cooling 0 Btuh
Actual heating fan 720 cfm Actual cooling fan 720 cfm
Heating air flow factor 0.058 . cfm/Btuh Cooling air flow factor 0.048 cfm/Btuh
Space thermostat Load sensible heat ratio 81
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
„~, wr~+ghtsoft Rlght-Suite Residential T"" 5.0.66 RSR29784 2006-Nov-01 12:29:32
~C(\ C:\Documents and SettingslcustomerlMy Documents\WrightsotilD. Lee Ross Townhouse,Ahern St-Center U Pege 1
~'11~. ~
E:~ A C4P
NOTE: SEE INFkYIDUAL T'~5T REPORT(S) FOR OP RA1'ItIGS AND MAXiIiM,lN AI.i.O1NA8LE SIZES.
t3etter8ilt poars d. Windows / CapH'td Windows b Doors appnedates your recent purt;hase of a maintenance- troe prime
window, which Wai rid rust, rot, mildew. or warp. This is a quality product that left our factory in goad condition -proper
handling arrd tnstallatian are just as impotrlar-t as gaol design and warkmanshlp. Please follow these r+eoommendations
W sllaw his product to oomglele its function.
t. Hander units one at a time in the dosed and locked position and take Cate hat to watch frame or glass or to fiend
the Waiting fin. I'tace a continuous head of caulk on the dock side of nail fin (mounting flange).
2. Set unit pWmb and square into Opening and make sure that there is 3/16' ± iMtl' dearance around the flame.
Fasten unit into opening in the c~o'.•ed and locked position, making Swe that fasteners are screwed in straight in
order to avoid twisting ar bowing of the frame. Make Sure that sill is straight and level• Cttedc operation of unit
fl+egtuently as fasteriecs atre set.
3. Use ~ tl sheet metal or wood screws wr'Ih a minimum of 1' penetration into the wood framing (stuff. place first
screws (two at each oorreer) 3' maximum from end of fin. For positive and negative DPs (design pr+essun~) up to
alt, da not exceed 2;° spacing of additional screws. For DPs from 36.1 to 56, do not exoe+ed 1ti" spacing. For DPs
from 55.1 to 89.3, da nol exceed 12" spacing.
~. Caulk entire perimeter of fin to mounting surface joint and caulk aver screw heads.
Note: this step can pe efrririated t< d' wide adhesive type flasnitg i5 used (sill t'~, lambs 2"a, tread 3'g.
5. FiN voids ia~etween frame atnd constnidion with loose batten-type insulation pr nortexua~tdirfg aerosol foam
speaficaily formulated for windows and doors to eGrninate drags. Tt~~ of e~ndino aerosol type insulating
foam, which can bow the frame, waives a~ stated warranties. ~~ t•xNS exa~iM~
. ~Z) ~- .
B. Remove plaster, maRar, paint, and debris that has coNeded on the u1u! and' rr:ake acre tizat the sash tracks and
interlocks one also dears. l~ not use abrasives, solvonls, arrimoriia, vmL(lac', 9lkaJiriE; or~ acicl,salutions for dean up.
•~•s~~.311y w~rh ~rryc;,a:ed r;tass units as their use could cause Chemical breakdown Ot the g{asr. seal. Taloe Care nW
4o scxatch glass; scxah~ies severely w9adcen glass and R coaki etrent~ halttt thermal expansion artd
condadiari. Clean ixH1s with water and mdd detergent. 6ui ?t?D4
~flreg l~~ect;~
^AUTI Dl-rlslon .., ~,~., FZ,
t3etterl3ilt doors ~ Windows 1 Capital Wrndows 8 Doors or lls ~~m ~".`.~ ~ alt~aillaAie• and carxiot assume
responsibility for the selection arW placement ad their products in a buBdingc_ture in a ma aired by taws,
statutes, arrdlor building codes. The purchaser is solely responsible for knowled6e-"af~ mince to the same.
Better8iitt /Capitol window products are not provided with safety glazing unless speaFn arderedwith such. Many
laws end codes require safety glazing {tempered glassy near doors, tsatMub4s. and stttower enclosures. Also, be aware
of other code requirements such as emergency egress and strucxurat J erwrgy performance.
Corporate Headquarters: - ~ _ ~ ; www.mihp.cam
M.t. Home Products Eric Nielsen, P.E. #0041323 : ' , • ~'';' r , , • . 7 y'~,.
650 Wes! Market St. Product Technology Corporation ~ r`. ~ ~, .• r ~• ~tirfi%'~~
. ;.
Gratz, PA 't7f13Q-0370 ' 71st? Louisiana Ave, Suite B ~I~ : ~ .~'~ ~ '~ ~ • n. r
(T1J~ 365-3300 Winter Park, Florida 32785 ~~ ~~ ~'• `'•• t~ r:
407 szz-saa4 _~ . ~ ~~ "
www.ptc-corp.com ~ z•~~l;Y~l~ „ -~'' arxrm~s
..•:
i~d
Arthiteetural Testing
tlu+~aii4e ++t~Ne t~~ttroER
C ESC QP IANC$
KEEP 1'FtIS PLAN ON J48
SEP 2 1 21104
Bt+ikUr-g Ina,.ect+on DiYisian --1ax.. FL.
Exarntnlr Sianaiurp' •_,._...__.._.. ___.._._
4kense Na.
ANSIIAAMAINW'WDA 101li.S.2 97
TEST REPOYtT
Rendered to:
MI HONE PRODUCTS, IlwiC.
SERIESlMODEL: 1$55St31$SSH
PRODUCT TYPE: A[umluum Single Hung and Oriel Windows
Sun~na of Results
Title Test S ecimen #1 Test S en t{2
Ratio H-R55 53 x73 H-RSS 53 x T3 Oriel
d tin Force 1 S lbf max. 151bf max.
Air Infiltration 0.06 cfrnf 0.03 cfm!
Water Resistance Test Pressure 9.3 sf i9.3 sf
Uniform Laad Deflection Test Pressure +56.7/x61.5 f +56.7/-69.3 f
Uniform Load Structural Test Pressure +$5.051-92.25 f +85.05!-144.0 sf
Forced En Resistance Grade 10 Grade 10
Reference should be made to ATI Report Idet-tsficatiot! No. Ol-4S484.02~far complete test
specirreen description and data
t 30 Derry Court
York, PA 17A02.94U5
phone: 7'1 i•76+1-77W
fsx: 717.764-4t29
www.archtest.com
~•~
Architectural Testing
AN~.iIA~-MAtNWWDA 101.1x.S,Z-~7 TEST REPORT
ReBderod to;
NQ HOIVIE PROD'ETCT3, INC.
P.O. Box 37fl
Gratz, Pennsylvania 17430-0374
ATI Report Identification No.: p1-46984.42
Test Dates: 09115/43
Through: lOtfl7103
Report Detc: 46/11/04
Expiration. Date: 10/87!07
Project Seaamary: Architectural Testing, Inc. (AT)7 was contracted by MI Hake FtQduets, Inc.
to perfMat testing on two SerieslModel 1855H/31855H. aluminum singe htrag and aniel
windows. The samples tested suscessR~lly met the performance requirctnents far the following
ratings: Test Specimen #1: H-RSS 53 x 73; Test Specimen #2: H-RSS S3 ~ 73 (Oriel). Test
specimen des<xiption and results are reported herein.
Test S~ecificatios: The test specimens were evaluated in accordance with
ANSUA~~1~iAlNWti'UDA IOIfI.S~,2-97, t~oleintr~ry Specifscatio~rs jor Alu~~'~~~~jia~nd~t
if~ood ~indaws acrd Glprss Deers. R$VIEVP~I~ j'i'QR
COia$ CQMPI.,LANGE
Test Speciaren Description: K£ER ~TNIS PLAN Qh 108
SerieelModel: 1$SSH13185SH
SEP ~ 1 zQOa
Product'f`yge: Aluminum Single Hung and Oriel Windows Bniiding InsteGk-On UIYISICQ -1ax., FL.
Test Specimen #i: H R55 53 x 73 xam:ner suture
License tVo., ._..._
Overall Size: 4' 4-1/$" wide by S' 11.3/4" high
Active Sash Size: 4' 2-3/8" wide by 3' 0" high
Fixed Daylight Opening Size: 4' 1-3l8" wide by 2' 8-5/8"high
ScreeA Size: 4' 2-3/4" wide by 2' 11-1/2" high
~ 3C1 Derry Court
York, PA 17401.44U5
pharie: 717.76M7700
fax: 717-7644t29
www.arChtest.cam
Architectural Testing
Test Specimen IIescrigtian: (Continued)
Test Specimen #2. H-R55 53 x 73 (Oriel)
Overall Size: 4' 4-1/8" wide by 5' 11-3/4" high
Active Sash Size: 4' 2-3l8" wide by 2' fi" high
Fixed Dayligi~t Opening Size: 4' 1.3/8" wide by 3' 2-9/16" high
Screen Size: 4' 2-3/4" wide by 2" 5-7116" high
?'he following descriptions apply to all speclmess
Finis: All aluminum was anodized.
O1.46984,42
Page 2 of 8
Glazing Details: The window utilized a 118" thick sheet of clear tempered glass exterior
glazed onto a glazing compound and secured with PVC snap-fzt glazing stops.
Weatherstripping:
Description
0.187" backed by U.23fl"
high palypile with
center fin
0.187" backed by 5/16"
diameter vinyUwrapped
dual-fin foam bulb gasket
7J8" by 51$" by 0.190"
high polypile dust plug
anti Location
1 Row Fixed meeting rail and stiles
1 Row Bottom rail
2 Per Window Ends afeach interior meeting rail on
Test Specimen #2 only
Frame Codstrurtion: The window frame members were constructed of extruded
aluminum. An ah~mirn,m vertical sill leg extension was sealed to the sill with silicone. All
corners were coped, butted, sealed, and fastened with two #8 by I" panhead screws. The
ends of the fixed meeting rail were sealed and fastened with two #$ by 1-1/Z" panhead
screws per jamb.
Sash Construction: AIl sash members were constructed of extruded aluminum. All
corners were coped, butted, sealed, and fastened with two #6 by 1" panhead screws.
~~~,. Ol-4b984.U2
Architectural Testing Page 3 of S
Test Specimen Description: (Continued)
Screen Construction: All screen members were constructed ofroll-formed aluminum. All
corners were keyed. The screen mesh was secured with a flexible vinyl spline.
Rardware:
Description uS) anLty' Location
Metal sweep lock 2 8" from ends of each interior
meeting rail on all fast specimens
Block and tackle 2 Une per jamb on all test specimens
balance system
Plastic pull tabs 2 4-112" from ends of screen bottom
rail on all test specimens
Vinyl sash guide 2 2-114" from tog of each stile on all
test specimens
Metal spring retainer 2 Ends of screen tap rail on all test
bar specimens
Plastic caps 2 Ends of interior meeting rail on all
test specimens
#6 by 1/2" panhead 2 2-112" from ends of screen bottom
screw rail on Test Specimen #2 only
Drainage:
Description ti Location
1-3/S" wide by 5/16" 2 Ends of center vertical sill leg
high weepslot
1- l /8" wide by 3/ 16" 2 Ends of exterior verkical sill leg
high weepslot
114+' wide by 1/8" 2 Bottom of each jamb draining the
high weepslot jamb hollow on Test Specimen #2
only
118" diameter weephole 2 Mids an of each 'amb at ends of the
flxedprneeting ra~ on Test Specimen
#2 only
~•~
1'~~ O 1-46984.02
Architectural Vesting Page4of8
Test Specimen Description: (Continued)
Anchorage:
Description. uanti ~tign
3116" by 1-3/4" flathead 10 3" from ends and midspan at the
Tapcon screw head and sill, 3" from bottom of each
jamb and 2" from tap of each jatrab
on Test Specimens # 1 and #2
12 by 2" flathead screw 2 32-3!$" lsorn bottom of each jamb on
Tcst Specimen #1
#12 by 2" flathead screw 4 32-3l8" and 28" from bottom of each
jamb on Test Specimen #2 only
Reinforcement: No reinforcement was utilized.
Instalta6on The window was installed into aSpruce-Pine-Fir #2 2x10 wood test buck
with ten 3l16" by 1-3l4" Tapcon fasteners and two (four on Test Specimen #2) #12 by 2"
flathead screws. The Tapcon screws were located 3" from each end and midspan of the
head and sill, and 3" firom each end of the jambs. The #12 by 2" screws were located 32"
from the bottom of the jamb on Test Specimen #1, and 32" anal 2$" on Test Specimen #2.
The exterior perimeter was sealed with silicone.
Test Results:
The results are tabulated as follows:
1'araexa~h Title of Test - Test 1Vlethod Results A owed
Test Specimen #1. H-1355 53 x 73
2.2.1.6.1 Operating Force 15 lbf 301bf max.
2.1.2 Air Infiltration per ASTIVI E 283
1.57 psf (25 mph) 0.06 cfmlft 0.3 cfm/ft~ max.
Note #l: The tested specimen meets the performance levels specked in
ANSI/f1ANf.4/NWWD~i IOUI.S.2-97. for air infiltration.
~•a
~~~ 01-~4b984,Q2
Architectural Testing Page5of8
Test Izesuits: (Continued}
Fara;~raph Title of Test ~ Test Method Results AIlowed
Test Specimen #I: H-R55 53 x 73 (Continued}
2.1.3 Water Resistance per ASTM E 547 (See Note #2)
Rote #2: The client opted to start at a pressure higher than the minimum required. Those
results are listed under 'G-ptional Performance'.
2.1.4.1 Uniform Load Deflection per ASTMI E 330 (See Note #2)
2.1.4.2 Uniform Laad Structural per ASTM E 330 (See Note #2}
2.2. I .b.2 13eglazing Test per ASTM E 987
In operating direction - 70 Ibs
Active meeting rail 0.10"/20% O.SO"1100%
Bottom rail 0.10"IZO% 0.50"/100%
In remaining direction - 50 lbs
Left stile 0.10"120% 0.50"/100%
Right stile 0.10"120°r6 0.50"/100%
2.1.8 Forced Entry Resistance per ASTM F 588
Type: A Grade: 10
Lock Manipulation Test No entry No entry
Test A 1 through AS; A7 No entry No entry
Lock Manipulation Test No entry No entry
,~~
r~
'~~ OI-46984.02
Architectural Testing Pagebof8
Test Results: (Continued)
Test Specimen #l: H-R55 S3 x 73 (Continued)
Para~a-aoh Title of Test -Test Method Results Allowed
Optional Ferformance
4.3 Water Resistance per ASTM E S47
(with and without screen)
9.3 psf No leakage No leakage
4.4.1 Uniform Load Deflection per ASTM E 330
(Deflections reported were taken on tl~ faced meeting rail)
(Loads were held for 30 seconds)
56.7 psf (positive) 0.74" See Note #3
61.5 psf (negative) 0. $2" See Note #3
11~'ote #3: The Uniform Load Deflection test is not at requirement of ANSIlA141bfAlN1~WDA
IOl/I.S.2-97 for this product designation- The deflection data is recorded in this report for
special code compliance and information only.
4.4.2 Uniform Load Structural per ASTM E 330
(Permanent sets reported were taken on the faced meeting rail)
(Loads were held far 30 seconds}
$5.05 psf (positive) 0.09° 0.21" max.
92.25 psf (negative) 4.41" 0.21" max.
Test Specimen #Z: H-RS5 S3 x 73 (Oriel)
2.2.1.6.1 Operating Force I S lbf 301bf niaac.
2.1.2 Air lnfrltration per ASTM E 283
1.57 psf (25 mph) 0.03 cfm/fl 0.3 cfmlfiz max.
2.1.3 Water Resistance per ASTM B 54? (See Note #2) .
2.1.4.1 Uniform Load Deflection per ASTM E 330 (See Note #2)
2.1.4.2 Uniform Laad Structural per A5TM E 330 (See Note #2)
a
,~~ 01-46984.02
Architectural Testing Page?of8
Test Results: (Continued}
Test Specimen #2: H-R55 53 x 73 (Oriel) (Continued)
Parasranh Title of Test -Test Method Results Allowed
2.2. I.6.2 Deglazing Test per ASTM E 9$7
In operating directian - 70 lbs
Active meeting rail 0.10"120% 0.50"/100%
Bottom rail 0.10"/20% 4.50"/100°/n
In remaining direction - SO lbs
Left stile 0.10"/20% 0.50"/140°/a
Right stile 0.10"120°!0 0.50"/100%
2.1.8 Forced Entry Resistance per ASTM F 588
Type: A Grade: 10
Lock Manipulation Test No entry No entry
Test A 1 through A5; A7 No entry No entry
Lock Manipulation Test I`~Ta entry No entry
Ontiona! Performance
4,3 Water Resistance per ASTM E 547
(with and without screen}
9.3 psf No leakage No leakage
4.4. i Unifatm Load Deflection per ASTM E 330
(Deflections reported were taken on the fixed meeting rail}
{Loads were held for 30 secands)
56.7 psf (positive) 0.62" See Note #3
69.3 psf (negative) 0.80" See Note #3
4.4.2 Uniform Load Structural per ASTM E 330
(Permanent sets reported were taken on the fixed meeting tail}
(Loads were held for 30 seconds)
85.05 psf (positive) 0.03" 0.21" max.
104.0 psf (negative) 0.04" 0.21" max.
'~~~ 0 L-46984.02
Architectural Testing Page 8 vf8
Detailed drawings, representative samples o~f the test specimen, and a copy of this report will be
retained 6y ATI far a period of four years from the origins! test date. The above r~asults were
secuzed by using the designated test methods and they indicate compliance with the performance
requirements of the above referenced specification. This report does nat constitute certification
of this product, which may only be granted by the certifcation program administrator. This
report may not be reproduced, except in full, without approval of Architectural Testing, Tnc.
Far ARCHITECTURAL TESTING, INC:
t. A~
i ( ~f .t~ .~~~~~~~~' 006
.. .'h }
O~dYfy 9pt~iby:A~m A FoOOr
Adam Fodor
Supervisor -Product Testing
p~ z 2/
Oip~rSpud6y: &euan k tXi[F~
Steven M. Urich, F.E.
Senior Project Engineer
AF:vfm
O1-4G984.02
~7T~CW/u~',vr ~"~
M I A M I~DADE
BUQ~DING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
MIAMI-DADE COUNTY, FLORIDA
METRO-DADS FLA(~LF.R BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
NOTICE OF ACCEPTANCE (NOA)
Ml Home Products, Inc.
650 West Market Street
Gratz, PA 17030
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami-Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in azeas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product ar material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, ar suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami-Dade County Product Control Division that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Series ~BetterBilt D185SH/D3185SIP' Aluminum Single Hnng Window
APPROVAL DOCUMENT: Drawing No. 5-2422, titled "Non-Impact Single Hung Window Rectangle Circle
Top & Oriel", sheets 1 through 5 of ~, prepared by RW Building Consultants, inc, dated 10/27/03 with revision
" 2", dated OZ/10/04, signed and sealed by Wendell Haney, P.E., bearing the Miami-Dade County Product Control
Approval stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product
Control Division.
MISSILE IMPACT RATING: None
LABELING: Each unit shall bear a permanent label with the manufacturer's name yr logo, city, state and
following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of this page 1 and evidence page E-1, as well as approval document mentioned above.
The submitted documentation was reviewed by Theodore Berman, P.E.
~I/ (~~ c NOA No 03-1215.02
t ~ Expiration Date: March 04, 2009
Approval Date: March 04, 2004
b~ Page 1
2~
MI Home Products, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No. 5-2422, titled "Non-Impact Single Hung Window Rectangle Circle Top &
Oriel", sheets 1 through 5 of 5, prepared by RW Building Consultants, inc, dated
10/27/03 with revision " 2", dated 02/10/04, signed and sealed by Wendell Haney, P.E.
B. TESTS
1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Forced Entry Test, per FBC 2411.3.2.1 and TAS 202-94
along with marked-up drawings and installation diagram of an aluminum single
hung window, prepared by Architectural Testing, Inc., Test Report No. ATI
03056, dated 11/11/03, signed by 3oseph A. Reed, P.E.
C. CALCULATIONS
1. Anchor Calculations, ASTM-E1300-98, and structural analysis, prepared by R.W.
Building Consultants, Inc., dated 12/11/03, signed and sealed by Lyndon F.
Schmidt, P.E.
2. Revised Anchor Calculations, and structural analysis, prepared by R.W. Building
Consultants, Inc., dated 02110/04, signed and sealed by Lyndon F. Schmidt, P.E.
D. QUALITY ASSURANCE
1. Miami Dade Building Code Compliance Office (BCCO).
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of conformance and no financial interest, dated December 09,
2003, signed and sealed by Lyndon F. Schmidt, P.E.
2. Statement letter of no financial interest with the laboratory that performed the
Test Report No. ATI 03056, dated November 08, 2003, signed by Stu White,
Design Engineering Manager.
G. ,OTHER
1. Letter from the consultant stating that the product is in compliance with the
Florida Building Code (FBC).
Theodore Berman, P.E.
Deputy Director, Product Control Division
NOA No 03-1215.02
Expiration Date: March l?4, 2009
Approval Date: March 04, 2004
E-1
* MI HOME PRODUCTS
a 650 WEST MARKET STREET • GRATZ, PA • 17030-0370
SERIES SETTERBILT D185SH/D3185SH
ALUMINUM SINGLE HUNG WINDOW
GENERAL NOTES:
i. THIS PRODUCT IS DESIGNED TO COMPLY WITH 7HE "HVHZ" OF THE FLORIDA
auTLOINC cooE.
2. WOOD BUCKS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS
70 STRUCTURE AND TO 8E RENEWED BY BUILDING OFFICIAL
3. PRODUCT ANCHORS SHALL 8E AS LISTED AND SPACED AS SHOWN ON DETAILS.
ANCHOR EMBEDMENT 70 BASE MATERIAL SHALL BE BEYONp WALL DRESSING OR
STUCCO.
4. FOR DESIGN PRESSURE RATING SEE TABLE THIS SHEET.
5_ IN57AUATION OF THIS SYSTEM IN HVHZ AREA REQUIRES 7HE USE OF APPROVED
SHUTTff2/EXTERNAL PROTECTION DEVICE COMPLMNG WITH HVHZ REQUIREMENTS;
INSTALLATION OF THIS SYSTEM OUTSIDE OF HVHZ SHAL! MEET THE APPLICABLE
CODE REQUIREMENTS .FOR WINOBORNE DEBRIS PROTECTION.
6. THIS PRODUCT MEETS WATER REQUIREMENTS FOR HIGH VELACITY HURRICANE
ZONES.
53.7 25" MAX.
OVERALL '
FRAME WIDTH
49.375° MAX.
D.L.O. WIDTH
I
J ~~
~ '1/~ I a
~ o
J
w~ - J
No
o w
x 1
3 ~ °M'
X
Q g
`~ ~ X /
r` ~N NXO
J
r
~
~
~ o
N
53" x 73" SINGLE HUNG WI NDOW
CIRCLE TOP ORIEL
53.125" MAX.
OVERAI.I
FRAME WIDTH
49.375" MAX.
D.L.O. WIDTH
53.125" MAX. 36" MAX. OVERALL
- OVERALL FRAME WIDTH 33.313° MAX
FRAME WIDTH D.L.O. WIDTH
_ 49.375" MAX. ~
D.L.O; WIDTH 2
2
~ ~ ~o
~ ~ ~ J
II] J ~_ ~~
N
J
~ ~~ 0~ M
¢r Nx
M z 3
o W ~
~ 3 / ~ ~
Q' ~ '~"~
~ ~ a
n ~,,
z /G ~ I
~~ f ~ /~ inO q
°p ~N ~U
=
irk
I~ N 0
V] '~'t J
'
p
O ~ X ~~ ~
M
f r1
53" x 73" SINGLE HUNG WIN DOW 37° x 84" SINGL E HUNG W N1 DOW
36° MAX. OVERALL
FRAME WIDTH
33.313" MAX 36" MAX. OVERALL
. FRAME WIDTH 33 313" MAX
/~1 Q.L.O. WIDTH ~ 1 D.L.O. WIDTH
I ~ ' ~ I
J
w= S
_ o
O O
Y N J
r
~ O
xQ
~ ~w 1
3
i°n
. ¢~
~W
-
~ E
` mxxZ
¢ ~ /~ NXO
Q J
O Q
~ ~ ~
try ~ ~
~ ~ 0
~ I /1 ~
J
~ . o
J
=
O
1 ~ ~ N ~
M
Z
4 W
g ~ X / //
r ~y ~O
O ~ r`
N O
53" x 73" SINGLE HUNG_ WIN DOW
HALF GRCLE TOP ORIEL
TABLE OF CONTENTS
SHEET DESCRIPTION
1 GENERAL NOTES & TYPICAL ELEVATIONS
2 VERTICAL CROSS SECTIONS
3 HORIZONTAL CROSS SECTIONS & GLAZING DETAIL
4 ANCHORING LOCATIONS
5 COMPONENTS, BILL OF MATERIALS
37" x 84" ~,NGI_E HUNG WINDOW
CIRCLE TOP ORIEL
DESIGN PRESSURE RATINGS (PSF)
GLASS MAX. SIZE OP POS. DP NEG.
1/8" Temp. OA 53" x 73" +56.7 -69.3
1/8" Temp. OA 37" x 84" +56.7 -69.3
3/16" Anna OA 53" x 73" +42.0 -42.0
3/16" Ann. OA 37" x 84" +56.7 -58.0
' ~ i
J I
/ X
W
S= ~ ~O
O ~ ~n -!
1
/~ ~~
~ ~
3 o
.n
_ ¢~
i(7
-~-
-
~
~ ~ ~ O
M ~ ~
37" x 84" SINGLE HUNG WINDQ~V
HALF CIRCLE TOP ORIEL
r ~lyiy
e
Bn N
cp
~ w
w m
n u ~ ~
~.
~€
~~ap~ ey
•K 't Yi d
~ O~ Y
N > O! O
cz, n° ° E
cr n '~ c
my x
v oZ
~m•9
oo.~a ~
m~ 6 U~3
dfZ
N~
o~
z
J W
J
Z0.
~~
N.T.S.
er; TJH
~: Rw
~ x~
5-2422
1 uF °
N I~
ti
N
X
G
n
x~
0
rn
n
O
Z
1.25" MA.
EMB.
a
a .
Qa.
•d
Q'
1.34" MIN.
EMB.
~~
1 x
~ 3
i
N
~O~
Z~
~O
~D
r
r 0
pXN
1~
~n
Q T. -~I
~ O
Z
C1
(*y1
Dm
r
cn c~
Z
W
.25" MAX.
SHIM
S fOR OVERALL HEIGHT
1.19" MIN
EMB.
Z of
m `~
Nm
z
~ rn
~~
• r
1.25° MIN.
EMB.
n d .
'e~
9
A •.,~ ,
d
4 < a
d
T
ZN
m
Om
m
N fTl
wZm
~~
r
~ Y > VVVV~• BVILf`1(JG CONEVLTRi~IT$, INC.
~ x ~ ~' ~ NON-IMPACT SINGLE HUNG Gj~
~ ~ ~ ~ •• _. WINDOWS RECTANGLE. .! ~P.o, gox 230 Valnec',rL .3:3595
~ CIRCLE TO FL OREIAL Phone No:: X73.839.9197
N
Floritlo Bxrti o~'Pw' aional Enginaaro
Certlficvlr. f Aut~xa` otton No, 981J
~ N : ~ s ti yo 2 011 044 C RREC 0 A RW PART OR ASSEMBLY: z/~o/o4
iv VERTICAL
~~' ~+ NO GATE _ BY CROSS SECTIONS a.,aan >! .E M `.+435®
------ SEE SHT. 1 ELEVATIONS FOR OVEKHLL rtti~rti
$
~ 0
,o ' _625" GLASS c~ Y = ~ N
~ 1
46" MIN. BITE 21 ^ ~ ,~
w O1
.
'
EMB.
M
~ ~
n
~
~
~
'r
°
a
° .25" MAX. ~
2 ~
~ .
i
u
n n o '1'
F
2 'v '- SHIM ~~ z
~ k" Em F
~' ~.t
a J
'
1 C9tn ~ ~_
°
8 - .
. o~ 21 2 tai <
W E t >
ri-o t
'
20 1-
7 (/1 ~ zom
u N 4
• Q p
p
_ x .m x
D' ')
~ 3
9 .qo Y
~ 5 r o o S
m
~~ .
' 9 2 2 ~f16" ANN~'~O GLASS ~
'° GLAZING DETAIL o p~
:, ' p° ,~ GLASS TYPE "A" a V~1
° .> 19 N z
ETA 1 2X
a 2
9
21 2
~ C1
?
w p
NOTE 2 SH 3 Y ~ w J
°' ••PO
v
~ .625" GLASS =
2
~ ~ "~¢
. BITE N ic~~°`I No
O
~ o ~ oN
HORIZONTAL CRO
r~
3 .W/2X BUCK SS SECTION ^1 ~N~
¢3
w uW, ~~
o
7 Z ~ V ~ ( ~
z
IN•
1
2 1 8' TEMPER D GLASS ~ a
EMB.
.
9 GLAZING DETAIL
GLASS TYPE "B" ~
~ =
3 r
m
2 24
' °a '
• d
' e
°
.25" MAX.
~I ~
z ~
?
~
m
w
N
0
29 ~ SHIM ~
~ N
g NOTES: ti o
~
o
v' 1. THE MAIN FRAME HEAD, SIDES AND SILL ARE CONNECTED
o
~' 1 ~ 1
-
-~ TOGETHER AT EACH CORNER WfiH (2) ITEM #11, A
.. n
w F
21 22
21 2 w ~
7
#8 x 3/4" PHILLIPS PAN HEAD SCREW. THE SCREWS
~--
m
° 20 7 m o B
m p RUN FROM THE HEAD DOWN INTO THE SIDES AND FROM ~ ~
J
± THE SILL UP INTO THE SIDES. ~ -
' p °
' -
-
_T 2. THE FIXED MEETING RAIL. I5 SECURED TO THE SIDES
" P
I
2 a m
I ~ TH (
) EACH SIDE ITEM #12, A #8 x 1 1/4
W
HILLIPS
c
9
8 PAN HEAD SCREW, v
n 3. THE SASH CORNERS ARE CONNECTED TOGETHER WITH o ~
.. - (2) EACH CORNER ITEM # 13, A /j6 x 3/4" PHILLIPS ' o 0
a PAN HEAD SCREW
P
° a
19
19 .
N
^
z
SEE GENER
L •~ 9 9 ~~ 10/27/D3
A
1X 21 22 21 2 0
~~~ S
~
NOTE 2 SHT. 1 2fi 3 3 ~*~
~ .
' N.T.
D V
owc. er: 7JH
v' ~ cwc. ev: RW
G1 HORIZONTAL CRO SS S CTION l~1~ HORIZONTAL CROSS ECTION wawwc No,:
3 W 1X BUCK 3 SHOWING SASH CAM
MASONRY & BUCK N07 SHOWN 4 ~- 5-2422
srieEr 3 or 5
~' 3" (4j EQUAL SPACES a
3" 3" ~ 3° a SEE NOTE 3 N a
L~ r1 27 28 ~ ~ ~ NP 8
w~
27 28 T ~ iv 3" 3" ~,
T ~ I ~ 27 28 ~ I ~ ~ ~ 2
27 28 SEE 'h 27 ~ ~ ~ ~ ; _ ~ o ~ . ~
N 27 27 ~ NTYOP~ t ~ ~ 29 SEE iv 27 ~ 27 `~ SEE ~ 27 28 27 ~ ~ '° ~ m ..
29 ~ 29 ~ ~ NpE ~ 2g 29 NOTE 1 27 2g NOTE 2 ~ ~' c~ a °
T. / TYP 29 ~ TYP E :~ ~ ri o ` ,
27 // /~ / `~'oAmY~
29 %Ji ~ N 27 %l~ c c. N •• o
/// ~/~/ ~P x ~ m .1., _
27 Yfr e ~ ~ S = ~ '
29 aT ~ ~ ~ 27 -fit ~..~
~' ~ ~ ~ ~ tin 27 "~
27 27 is ih `° 2 _, 'n
I 27 29 "' 29 1 M 1 29 27 29 ~ L M~ 27 29 27 29 ` M ~ 29 27 29 ~_ x~~ ~
_i_. c~ o
•-~ -T- 14 --~- -~- I ---y- va .t; o
3„ 3„ =_I ~~ ~ ~ ~ 3„ 3" -~i f' `rnl'- `r7 ~`1 l'- 3" 3" -^{ ~-^- •M `rte -'~ ~- 3" ~1 ~~ J ' ~~ F°- m z
37"-x1814`" SINGLE HUNG-WINDOW 37" x 84" SINGLE HUNG WINDOW ~7" x 84" SINGLE HUNG WINDOW X53" x 73" SINGLE HUNG WINDOW ~z~ :(
HALF CIRCLE TOP ORI L CIRCLE TOP ORIEL ~ ~ 3U ~ z
~~o o
SEE NOTE 3 Cr`5 & z
TYP ~O~PL SPP 3„ ~ iv u 3 ~ ~
27 28 3 ~M~ 27 28 _l
~ 27 28 ~ w
N
l ~ 27 28 ~ 1 SEE J
_J__ /~ ~ NOTE 2
27 ~ ""' SEE NOTE ~ TIP NO-T~`= ~ ° ~
2 TYP 1. FOR UNITS SMALLER THAN 30"x60" DO NOT INSTALL ANCHOR AT ~ o o_
29 ` ~ ~ 27 CENTER LOCATION. N
27 N 27 ~ / 2. FOR UNITS SMALLER THAN 53"x60" OR SMALLER THAN 30"x66" p0 NOT o ~ ~
29 29 2g INSTALL ANCHOR A7 CENTER LOCATION. F-
3. FOR UNITS SMALLER THAN 3B"x86" DO NOT INSTALL ANCHORS AT w
EITHER SIDE OF CENTER ANCHOR A7 HEAD AND SILL JAMBS. ~
a a 27 ~ "~ //, ~ ip ~ p w
} ~ 11 O~ I-
~ v 29 ~ c~ ~ / 27 n NOo
-~ °ctE: i 0 27 03
~_._~ 3" ~.•-- 3" r wMYM scams: N.T.S.
' ~ 3" SEE NOTE 3 ~~ M V SEE NOTE 3 ~~ ~• ~` 7JH
TYP TYP cxx. ~': RW
(4) EQUAL SPACES
(4) EQUAL SPACES MMI onaranc x°'
F;" Y 73" SINGLE HUNG WINDOW ~~•~ x 73" SINGLE HUNG WINDOW ~ 5-2422
CIRCLE TOP ORIEL HALF CIRCLE TOP ORIEL
SNEEr 4 ov 5
BILL OF MATERIALS
!TE DESCRIPTION MATERIAL
1 EXTRUDED ALUMINUM SINGLE HUNG 1/2' HEAD
ACM-18501 BY MI METALS ALUM.
Z EXTRUDED ALUMINUM SINGLE HUNG 1/2" SILL
,ACM-18502 BY MI METALS ALUM.
3 EXTRUDED ALUMINUM SINGLE HUNG i/2" JAMB
ACM-18503 BY MI METALS ALUM.
4 EXTRUDED ALUMINUM SINGLE HUNG FIXED MEEi7NG RAIL
~/CM-18504 BY MI METALS ALUM.
5 EXTRUDED ALUMINUM SINGLE HUNG SASH LOCIf RAIL
#CM-18505 BY M1 METALS ALUM.
6 EXTRUDED ALUMINUM SINGLE HUNG SASH BOTTOM RAIL
ACM-18506 BY MI METALS ALUM.
7 EXTRUDED ALUMNUM SINGLE HUNG SASH STILE
ACM-18507 BY Mi METALS ALUM.
8 SASH CAM I-T85 BY BSI -
9 GLAZING BEAD V- i 85 8Y MI PLASTICS -
10 LOCK 30240-402 BY REFLECTOllTE
11 MAIN FRAME SCREW //8 x 3/4' PHHILLIPS PAN HEAD STEEL
12 MEEflNG RAIL SCREW 8 x 1 1/4" PHILLIIPS PAN HEAD STEEL
13 SASH SCREW 6 x 3/4" PHILLIPS PAN HEAD STEEL
14 LOCk SCREW 8 'x 5 8° PHILLIPS FLA7 HEAD -PTD STEEL
15 SASH GUIDE 80-02-8207 8Y PLASTICS, AZ -
16 WINDOW SCREEN -
7 7 F{N WFATHERSTRIPPfNG .187" x .250" BY AMESBURY -
18 BULB SEAL 32002 8Y AMESBURY -
19 DUST PLUG 5/8' x 7/8" x .25" BY AMESBURY
20 5/8" BLOCK & TACKLE 150 SERIES BY 8SI -
21 GLASS 'A" SGL GLAZED 3/16" ANN. BY GUARDAN
-
22 GLASS "B" SGL GLAZED i/8" 7EMP. BY GUARDIAN
23 BACKBEDDING SM-2100 BY SGHNEE MOREHEAD SILICONE
24 BACKBEDDING PURFECTGLAZE-H HOTMELT) -
25 GLASS SHIM 1 8" x 1/4° x 1" 8Y SECON -
26 T/4" MAX SHIM -
27 #12 X 2" PHILLIPS FLAT HEAD SHEET METAL SCREW STEEL
28 3 16" x 3 1/4" ELCO TAPCON ANCHOR STEEL
29 3 16 x 2 3/4" ELCO 7APCON ANCHOR STEEL
~ .045" -
O SASH BOTTOM RAIL
n
ro
N
1.8753"
m - ~~
~ ~
.203" '* "_~ N
o .187" -j---I + o
°? .OS"
~ •..
~--- 1.4058" ---~ - .357" -f ----
0
O SASH STILE ®SASH GUIDE BULB SEAL FIN WEATHERSTRIPPING
1.6449"
.D5"
OI.OCK RAIL
wo
~o
~U
o~
J~
m~
U~
1.436" .656" o
a
o°~
~] ~ N O
~ I
oah: t0 27 0.
"~ co ~ oo ~ N.T.S.
,~ ~ ~ ~ AyMsnisageybiK~lMe owc. er: TJH
mat anc er: RW
2.188" t ,062" --j ~" ~ orux~NC NO.:
5-2422
O HEAD FLANGE ®$ASH CAM ~~ sN~r 5 ov °
r °
g .~ ~
C ~^ ~
}` Q
81 h ~ O W
9 ~n 'az
z M ^ c ~
a8~m~~
~~~ae
r ~~na,
J W
S o~
N7vi o'
~. z c-a '
~ N ~~ p
O~Z m'om'
2 V ~ ~
~9ooao
S maa ~u 3
i,
o
a
SILL FIN
O JAMB-FLANGE
® FIXED MEETING RAIL