Loading...
Permit 61 Beach Ave r' r r • s l r JOB ADDRESS S2--_ TYPE WORf6 1k U PROPERTY OWNER P/I Z LO�� TE EPHONE -'1 1 I 3-15D CINTIiACTIIt PERMIT NUmtBER DATE (O- [ Is I INSPEMONS• FOOnNG �I l SLAB •?• 3 •C� 1 �66- Yip- nEBEAM LLVTEL F14A�lT1VGrC09CP INSULATION FLVAL BUILDC CERTIFICATE OF OCCUPANCY FT.F.CTRICAL PF1xHIT# INSPECTIONS ROUGH FINAL MEC YAMCAL PERW" INSPECTIONS ROUaff 0 ' I FINAL.. PLUMBING PERM a INSPECTIONS ROUG41UNDER SLUL /0 TOPOUT WATERISEWER NOTES: CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247-5877 ., PERMI:T:INF„ORM TION ,. N.e; . LOCATION:INFORMATION .... .E... Permit Number: 22184 Address: 61 BEACH AVENUE Permit Type: BUILDING ATLANTIC BEACH, FL 32333 Class of Work: NEW Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s):5 Block: 33 Section: Square Feet: Subdivision: ATLANTIC BEACH Est. Value: Parcel Number: Improv. Cost: 72,840.00 y..' OWN'EF7.INFORMATION Date Issued: 6/16/2001 Name: FARZIN DARABI Total Fees: 2,522.72 Address: 63 BEACH AVENUE Amount Paid: 2,522.72 ATLANTIC BEACH, FL 32233 Date Paid: 6/16/2001 Phone: (904)241-3737 Work Desc: SINGLE FAMILY RESIDENCE/GARAGE:&APARTMENT CO TRACTQR S ”, PLIC NU-VISION NU-VISION DESIGNS & CONSTRUOTI N PERMIT 528.00 W ,TER I,MPAQT-'FES „ 290.00 KSEVyER IMPACT FE 1,250.00 , V{IATEFZ METER( AP : ° 85.00 ✓ RADf} I GAS-H,.R.S 3.08 �zRADON= Al &jj6 N d 0.16 CAWAL IMPROVE a 325.00 CPLISS CONNECTION � � � 35.00 OEtST.SURCHARGE. .: 5.83 Y � �gK � Fy� ¢SC005? 5 HARGE/ATL BCH zS 0.65 � sixx .zy... s*• ea` ". _ IT xs"5r : op Srt.BE REQUESTED AT LEAST 24 HOURS�PRIC�R TO INSPE NOTICE`- INSPECTf�f ,,, CTION BUILDING MATERIAL,,RUBBISH, D•,DEBRtS FROM THIS WORK MUST NOT BE P LED IN PUkIC SPACE, AND MUST BE CLEARED L�?,AND HAULtD' AWAY BY EITHER CONTRACTOR OR O f ER "FAILURE TO COMPL`�•uWITH.T E )INSTRUCTION LIENeVE SAN RESIN IN THE PROPERTY OWNER P/1ING E Ih,[ tlG- NTS" . R 41 ISSUED ACCORDING TO APPRO Qt PLA[VS WFQCH RF PART'OF � I P�F fkt� AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PRO IS 61�IS d4VW :ti, l operator. CtiI Ryd Date. 6/19/�i o1 keceipt:#922.72 610 ATLA TIC BE_ACH BUILDI EPT. Total Payment. CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Address-46 Am e Date_ Heated Square Footage —6AT- @ $ ,©� per sq ft = $ L/]3(00 Garage/Shed @ S '� per sq ft = $ Carpor /Porch - - @ $ dper sq ft = S 2- R�6 Deck C @ $ per sq ft = $ 0 Patio @ $ per sq ft = $_ 0 TOTAL VALUATION: $ 2,� 2 scrd 2r0 $ 2G,© Total Valuation 1st $ © O o 2 2- Remaining Remaining Value $At. per thousand o7 portion thereof TOTAL BUILDING FEE $ -Z + 1/2 Filing Fee $ ( ) Fireplaces @ $15 . 00 $ BUILDING PERMIT FEE $ WATER IMPACT FEE $ 9 SEWER IMPACT FEE $ 2 f-O WATER METER/TAP 11; - , CAPITAL IMPROVEMENT $ SEWER TAP $ --b RADON (HRS) . 0050 $ SECTION H PAVING ( ) $ b HYDRAULIC SHARES $ r0- CROSS CONNECTION $ 3 (/;-%) SURCHARGE . 0050 $ 3 OTHER $ GRAND TOTAL DUE ADDITIONAL PERMITS OR FEES: Mechanical Plumbing Electric/New Electric/Temp ; SwimmingPool Septic Tank Well Sign Finish Floor Elevation Survey Other CALCULATIONS and/or NOTES: CITY OF ATLANTIC BEACH Fixture Unic Worksheet For Macer Impact Fee FIXTURE UNITS ARE ESTABLISHED AS THE HF-ASUREzfENT OF WATER DE.N!ASD FOR Ea CH WATER FIXTURE UNIT INSTALLED AND CONNECTED TO THE C-^V WA7 R SYSTEi. THE WATER SUPPLY CH.�RGE IS HEREBY FIXED AT - Eti'TY DOLLARS PER FIXTURE UNIT CONNECTED TO THE Clit WATER SYSTE.' . ' BATHROOM GROUP CONSISTING OF SERVICE WATER CLOSET, LAVATORY b BATH ER IC. `c- :NK TRaP SAND TUB OR SHOWER STALL (6) G (8) WA7= CLOSET, TANX OPERATED WATER WATER CLOSET ( ) VALVE OPER.;TE] (a) BA7A=B/SHOWER (2) URINAL WALL SHOWER GROUP PER HEAD (3) FLOOR D R.a=`� (!) SHOWE3 STALL DOMESTIC (2) LAUNDRY T?s,Y (2) L.IVATORY (1) CCM-37—NAT—CS A,1„ S Iii'eC AIC (j) _WASHING XACHINE (3) 3 POT, SCULLZ3Y _ D I SHWAS HER (2) Z_ WASH SINK EAC: SET C O r-.T FAUCETS (2) CIiE?� SINX 2(_) DE.'1'iAL LAVATORY (!) _[Z7C3E:Y slur WZTII S�ASTE 3 DE.'iTAL UNIT OR CUSPIDOR (? CRIXI)EY (3) ) RIDE' URINAL STALL, WASHOU- (G) r-Z:SHIXG Imf SINX (8) C0eB I:IATI ON SIN:{ AND TRAY W I Tii ,COD DISPOS. (4) URINAL. ?=ES?AL, SYPHON .T— BLOWOUT (2) DRINKING FOUNTAZY LAVATOR,. BARBER/BEAUTY •--- SHOP (2) --L—ICE MAKER (�/2) S SURGEONS SINK (3) O LAVATORY, SURGEONS (2) JACUZZI (2) /'_ V URINAL STALL, WASHOUT (4) TOTAL FIXTURE UNITS /C/"- � $20.00 EAC:i JOB IRFOp-DATION_ �C PLAN REVIEW CHECKLIST PROPERTY DESCRIPTION: OWNER: - l G 1. Determine Occupancy Classification of the structure. Select occupancy classification �' J which most accurately fits the use of the Building. (Chapter B3) [�,] 2. Determine actual physical properties of building. ["� a. Determine building area each floor. (Area definition Chapter 62) [4 b. Determine grade elevation for building. (Grade definition Chapter 132) 14 C. Determine building height in feet above grade. (Height definition Chapter 62) [y" d. Determine building height in stories. (Story definition Chapter 132) [ e. Determine separation distance from exterior walls to assumed and common property lines. (Property line definition Chapter 62) [ f. Determine percent of exterior openings per floor. [✓J' 3. Determine minimum Type of Construction necessary to accommodate proposed structure. (Chapter 136) [✓]� a. Determine maximum allowable heights and floor areas for Types of Construction and Occupancy classification. (Table 8500) [..]� b. Check allowable height and area increases permitted. (Chapter 135) [,�]r 4. Check detailed Occupancy requirements. (Chapter 134) [ Y 5. Check detailed Construction requirements a. Fire Protection of Structural Members (Chapter B6 &Table B600) [ b. Fire Protection Requirements(Chapter B7 and Table B700) [ ,a/ C. Means of Egress Requirements(Chapter B10) [ ] d. Special restrictions if in Fire District. (Appendix BF The provisions of Appendix BF are applicable only where specifically adopted by Ordinance) [ 6. Review design as related to standards. (Chapters B16-B26) [� 7. Check other requirements as necessary. [ ] a. Construction projecting into public property(chapter B32) [ ] b. Elevators and conveying systems(Chapter B30) [� C. Sprinklers,standpipes and alarm systems(Chapter 139) d. Use of combustible materials on the interior(Chapter 138) [ e. Roofs and roof structures(Chapter B15) [ f. Light,ventilation and sanitation (Chapter B12) [ ] g. Other r r(0- ©( CITY OF ATLANTIC BEACH BUILDING DEPARTMENT Date By: — C , ��� Don C. Ford, Building bfficial don/sb.1 RECEIVED PROPERTY DESCRIPTION JUN 1 2 2001 Lot # , Block #3 3, Section # Subdivision: �rt�q,�1r.e f-V)4 City of Atlantic leach Building and Zoning Street Name /� DESCRIPTION OF WORK or Address: A> y (If in a FLOOD HAZARD Flood Zone: area complete page 3) /}T, Brief Description Class of Work: Ne Remodel/Addition: ZONING INFORMATION Type of Construction:- . Zoning „ Proposed District: Use: Estimated Value $ Exceptions or Variances Materials: Granted: Solid or Filled Ground: Roof: Method of Heating: OWNER INFORMATION Property Owner: �� � Phone: -21(#3737 AV . 6771-6036,014 Mailing Address Zip: CONTRACTOR INFORMATION C'm Contractor: Ali !// /�'1 p7— Phone: 4ry3'00'06 Mailing Address: Zip: Expiration STATE LICENSE NO: Date: I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH, WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL, STATE OR LOCAL RULES, REGULATIONS, ORDINANCES, OR LAWS IN ANY MANNER, INCLUDING THE GOVERNING OF CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION OF THE PROPERTY. I UNDERSTAND THAT THE ISSUANCE OF THIS PERMIT IS CONTINGENT UPON THE ABOVE INFORMATION BEING TRUE AND CORRECT AND THAT THE PLANS AND SUPPORTING DATA HAVE BEEN OR SHALL BE PROVIDED AS REQUIRED. Owner Signature DATE Contractor Signature DATE SWORN TO AbID SUBSCRIBED BEFORE ME BY /jWNbRrAAr 7jul THIS DAY OF ('+ NOTARY PUBLIC FORM 60OA-97 1 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 63 Beach Ave,Atlantic Beach, FI, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 648.0 33.05 3855.5 Double,Clear E 2.0 6.0 26.0 40.22 0.85 886.9 Double,Clear E 2.0 6.0 16.0 40.22 0.85 545.8 Double,Clear N 2.0 6.0 15.0 19.22 0.90 259.5 Double,Clear W 2.0 6.0 32.0 36.99 0.85 1005.3 Double,Clear s 2.0 6.0 26.0 34.50 0.78 696.1 As43uik Total: 115.0 3383.5 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 0.0 0.0 0.0 Frame,Wood,Exterior 19.0 697.0 0.90 627.3 Exterior 697.0 1.70 1184.9 Base Total: $97.0 1184.8 As-Built Total: 697.0 $27.3 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior wood 20.0 6.10 122.0 Exterior 20.0 6.10 122.0 Bass Total: 20.0 122.0 As43uik Total: 20.0 122.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 648.0 0.60 388.8 Under Attic 30.0 700.0 0.60 420. Base Total: 648.0 388.8 As-Built Total: 700.0 420.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 0.D(p) 0.0 0.0 Raised Wood,Adjacent 19.0 648.0 0.40 259.2 Raised 648.0 -3.99 -2585.5 Base Total: .2686.5 As.Buik Total: 258.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 648.0 10.21 6616.1 648.0 10.21 6616.1 Summer Base Points: 9581.8 Summer As-Built Points: 11438.1 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 11438.1 1.000 1.047 0.310 1.000 3715.7 9581.8 0.3573 3423.6 11438.1 1.00 1.047 0.310 1.000 3715.7 EnergyGaugeTM DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 63 Beach Ave,Atlantic Beach, FI, PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Points .18 646.0 6.76 1139.0 Double,Clear E 2.0 6.0 26.0 9.09 1.06 250.7 Double,Clear E 2.0 6.0 16.0 9.09 1.06 154.3 Double,Clear N 2.0 6.0 15.0 14.30 1.00 215.6 Double,Clear W 2.0 6.0 32.0 10.77 1.04 359.2 Double,Clear S 2.0 6.0 26.0 4.03 1.26 131.9 As4kdk Total: 116.0 1111.6 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 0.0 0.0 0.0 Frame,Wood,Exterior 19.0 697.0 2.20 1533.4 Exterior 697.0 3.70 2578.9 Base Total: 697.0 2678.9 As-Built Total: 697.0 1633A DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 O.OD 0.0 Exterior Wood 20,0 12.30 246,0 Exterior 20.0 12.30 246.0 Base Total: 20.0 246.0 As43utl11 Total: 20.0 246,0 CEILING TYPESArea X BWPM = Points Type R-Value Area X WPM = Points Under Attic 648.0 1.20 777.6 Under Attic 30.0 700.0 1,20 840.0 Base Total: 648.0 777.6 As4kdk Total: 700.0 640.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 0.0(p) 0.0 0.0 Rased Wood,Adjacent 19.0 648.0 2.20 1425.6 Raised 648.0 0.96 822.1 Base Tota: 622.1 As43uilt Total: 1426.6 INFILTRATION Area X BWPM = Points Area X WPM = Points 648.0 -0.59 -382.3 1 648.0 -0.59 X82.3 Winter Base Points: 4981.2 Winter As-Built Points: 4774.3 Total Winter X System - Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 4774.3 1.000 1.064 0.461 1.000 2340.8 4981.2 0.5340 2660.0 4774.3 1.00 1.064 0.461 1.000 2340.8 EnergyGaugeTm DCA Form 600A-07 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 63 Beach Ave,Atlantic Beach, Fl, PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2746.00 2746.0 20.0 0.91 1 1.00 2655.47 1.00 2655.5 As-Built Total: 2655.5 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 3423.6 2660.0 2746.0 8829.5 j 3715.7 2340.8 2655.5 8712.0 EFPASS::] ZHB 3T,� re � a CSD WB,�� EnergyGaugeym DCA Form 60DA-97 FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 63 Beach Ave,Atlantic Beach, FI, PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS _ SECTION REQWREMENTS FOR EACH PRACTICE CHECK_ Exterior Windows&Doors_ 606.1.ABC.1.1 Maximum%3 eftnisq.1t.window,area•.5 c R.door area. Euterlor&Adjacent Walls MA.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sols or sill plate;joints between ceder or wall panels at corners;utility penetrations;between wall panels&top/bottom plates;between waft and floor. EXCEPTION:Frame wafts where a continuous infiltration barrier Is Installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings>118"sealed unless backed by truss or joint members. — EXCEPTION:Frame floors where a continuous infaration barrier is installed that is sealed to the penitrate► netr*lons and seams. Ceilings 606.1.ABC.1.2.3 Between walls&cei ings;penetrations of calling plane of top floor;around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic aces.EXCEPTION:Frame callings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. _ Recessed Lighting Fixtures 6WA ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned spam tested Multi-story Houses _ 606.1 ABC.1.2.5 Air barrier on perimeter of floor m ft between boors. _ Additional Infiltration refits 60B.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded by all residences. COMPONENTS _ SECTION REQUIREMENTS _ CHECK_ Water Heaters 612.1 Comply with efficiency requirements in Table 6-12.Switch or clearly marked circuit breaker electric or cutoff as must bepp ided.External or Iwilt�4n heat trapuired. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficient of 78%. Shower heads 1612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 1610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed,insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min.insulation. _ HVAC Controls 607.1 _ Se rate readily accessible manual or automatic thermostat for each system. insulation 604.1,602.1 Ceilings-Min.R-19.Common walls-Frame R41 or CBS R-3 both sides. Common coiling&floors R-11. EnergyGaugeTm DCA Form 6MA-97 EnergyGauge®/ResFREES7 FLRIPA 2.02 ENERGY PERFORMANCE LEVEL EPL DISPLAY CARD ESTEWATED ENERGY PERFORMANCE SCORE'S =82.6 The higher the score,the more efficient the home. Darabi, 63 Beach Ave,Atlantic Beach, Fl, 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap:18.0 kBtu/hr _ 3. Number of units,if multi-family 1 i SEER: 11.00 _ 4. Number of Bedrooms 1 _ b.N/A 5. Is this a worst case? No _ 6. Conditioned floor area(ft') 648 ft= a N/A 7. Glass area&typo _ a. Clear-single pane 0.0 tf _ 13. Heating systems b.Clear-double pane 115.0 fh _ a. Electric Heat Pump Cap:18.0 kBtu/hr _ c. Tint/other SCISHGC-single pane 0.0 fe _ HSPF:7.40 _ d.Tint/other SC/SHGC-double pane 0.0 flz b.N/A 8. Floor types _ a. Raised Wood,Adjacent 11=19.0,649.W c. N/A b. N/A c. N/A 14. Hot water systems 9, Wall types _ a. Electric Resistance Cap:20.0 gallons _ a. Frame,Wood,Exterior R=19.0,697.0 ftp T EF:0.91 b.N/A _ b.N/A a c. N/A _ — d.N/A _ c. Conservation credits _ e. N/A (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0,700.0 W _ 15. HVAC credits _ b.N/A (CF-Ceiling fan,CV-Cross ventilation, c. N/A HF-Whole house fan, 1.1. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AV:Garage Sup.R=6.0,75.0 ft _ RB-Attic radiant barrier, b.N/A M&C-Multizone cooling, M&H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Constriction through the above energy saving features which will be installed(or exceeded) TftB sr in this home before final inspection.Otherwise,a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: _ Date: � r Address of New Home:_ City/FL Zip: 'coo WE *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating.If your score is 80 or greater(or 86 for a US EPA/DOE EnergyStrfi designation), your home may qualify for energy efficiency mortgage(HEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 407/638-1492 or see the Energy Gauge web site at www.fsec.ucfedu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. EnergyGauge®(Version:FLRIPA 2.02) DATE: 6/5/01 MANUAL "J" SUMMARY REPORT -------------- Prepared For: Prepared By: Darabi Garage Apartment R.B. Ellis Energy Design Systems Job Name: 63 Beach Ave *********************************************************************** DESIGN CONDITIONS For Atlantic Beach OUTDOOR INDOOR SUMMER WINTER SUMMER WINTER Dry Bulb 95 32 72 72 Wet Bulb 78 62 Daily Range 19 Daily Swing 3 Latitude 30 Elevation 29 Safety Factor 5 Latent Factor 29 *********************************************************************** Sensible Room Heating Heating Cooling Cooling Name BTUH CFM BTUH CFM ------- ------- ------- ------- WHOLE HOUSE 14396 480 14110 588 ------- ------- ------- ------- HEATING COOLING DELTA T 40 DELTA T 23 NOTE: **Calculated air flow is based upon load requirements Verify that air flow calculated is compatible with selected equipment requirements. *** PREPARED BY ENERGY DESIGN SYSTEMS 904-287-5339 DATE: 6/5/01 MANUAL "J" DETAILED REPORT FOR ENTIRE HOUSE Prepared For: Prepared By: Darabi Garage Apartment R.B. Ellis Energy Design Systems Job Name: 63 Beach Ave ************************************************************************ EXPOSURE GLASS NORTH SOUTH EAST WEST NE/NW SE/SW HORZ TOTAL ------------------------------------------------------------------------ AREA 15 26 42 32 115 COOLING 375 1040 3108 2368 6891 HEATING 480 832 1344 1024 3680 ------------------------------------------------------------------------ WALLS TOTAL ------------------------------------------------------------------------ AREA 697 697 COOLING 1115 1115 HEATING 1882 1882 ------------------------------------------------------------------------ DOORS TOTAL ------------------------------------------------------------------------ AREA 20 20 COOLING 264 264 HEATING 414 414 ------------------------------------------------------------------------ FLOOR AREA COOLING HEATING ------------------------------------------------------------------------ SLAB RAISED WOOD 648 583 1426 ------------------------------------------------------------------------ CEILING AREA COOLING HEATING ------------------------------------------------------------------------ UNDER ATTIC 700 1085 1050 SGL ASSEMBLY KNEE WALL ------------------------------------------------------------------------ MISCELLANEOUS COOLING LOADS --------------------------- People Sensible Load 600 Latent Load 1648 Lights & Appl. Load 1200 Latent Safety Btuh 82 Ventilation Load Duct Heat Gain 1090 Infiltration Load 961 Sensible Safety Btuh 635 TOTAL SENSIBLE LOAD 14425 TOTAL LATENT LOAD 1731 Summer ACH 0.5 Temp. Swing Mult. 1. 00 *** Total Cooling Load 17771 BTUH Or 1.48 Tons *** MISCELLANEOUS HEATING LOADS --------------------------- Infiltration Load 4857 Ventilation Load Duct Heat Loss 423 Safety Btuh 665 Winter ACH 1. 2 *** Total Heating Load 14396 BTUH Or 1.20 Tons*** CITY OF .4&4o e, Te4a - 57&va& ` 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 32233-5445 TELEPHONE(904) 247-5800 FAX(904)247-5805 SUNCOM 852-5800 DATE JEA Construction & Maintenance 2325 Emerson Street Jacksonville, FL 32207 Attention: Connie Re: Rough Electrical Inspections Dear Connie: Rough Inspections on the following locations have been completed and approved: PERMIT NO. ADDRESS a 3 `7 Le l `7 'a k-D-d r S - 1 z�� L Please call me at 904-247-5826 if you have any questions. Sincerely, ATLANTIC BEACH BUILDING DEPARTMENT Book 10026 page 730 PC 00 F� e: �`30 ka � NOTICE OF COMMENCEMENT`1E & Recorded06/12/2001 11:21:45 All JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTY TO WHOM IT MAY CONCERN: TRUST FUND 1.00 RECOBDiNG 5.00 The undersigned hereby informs all concerned that improvements will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. Description of Property64/ &91 1 General Description of Improvements (�r ;17. t Owner Address: j e-. Owner's interest in site of improvements: Fee Simple Title Holder(if other than owner) Name Address Contractor 1410 Address Surety (if any) Address Amount of Bond $ Name of person within the State of Florida designated by owner upon whom notices or other documents m be served: Name Address In addition to himself, owner designates the following person to receive a copy of the Leincr's Notice as provided in Section 713.13(1)(F), Florida Statutes. (Fill in at Owner's option). Name Address: A� Ownef Sworn to and subscribed,before me this, dayof Notary Public FORM 60OA-97 EFFICIENCY CODE FLORIDAENERGY C�'ION FOR BUILDING CONSTRU rtment of Community Affairs Florida Depa Residential VhO1e Building performance Method A Builder Atlantic Beach parabi Garage APartment Permitting Office Project Name: each Ave Address: Permit Number: city, Atlantic Beach'F1 Jurisdiction Number. y parabi Owner. North — --� Climate Zone: — Cap:New — 12. Cooling systems CaP:18.0 kgtu/hr — I. New construction or wasung Single family a,Central Unit SEER:11.00 — I Single family or multi-family 1 — — 3_ Number of units,if multi-family I — b.VA 4. Number of Bedrooms No — — 5. Is this a worst case? 648 fe a NIA — 6. Conditioned floor area(ft) 7, Glass area&type 0.0� _. 13. Heatung systems Cap: t8.0 kgtu/hr — a.Clear-single l� 115.0 ff a Electric Heat Pump HSPF:7.40 _ b.Clear-double pane 0.0 fe — c. Tintlother SC/SHGC-single pane 0.0 fe b.NIA — d.Tintiother SC/SHGC-double pane _ — S. Floor WPM c. NIA a.Raised Wood,Adiac"d _ b.N/A 14. Hot water systems Cap;20.0 gallons — Electric Resislanoe EF:0.91 9. Wall types R=I9.0.697.0fl— — a. Frame,Wood,F-Xtetror b.NIA — b.NIA — c. N/A — c. Conservation credits d.N/A (HR Heat recovery.Solar e. N/A _ D]Hp-Dadicatad heat pump) 10. Ceiling types .0700.0 i 15. HVAC credits R=30 , (CF-Ceiling fan, tilation, a Under Attic CV-Cross I b.Under W/A HF--Whole house fan, c. N/A PT-Progran mable Thermostat, 11. Ducts W-GMuitizone coding, a Sup:Unc. Rot:Unc. All:Gavage Sup."'0'75.0 ft — M"-Mulfizouc heating) b.N/A Total as-built points: 8712.00 PASS Glass/Floor Area: 0.18 Total base points: 8829.50 Review of the pians and ot�4a sr,� I hereby Y cifications covered specifications covered by this certif that the plans a a ce�h the Florida eo by this calculation are in campy calculation indicates compliance N s .� Energy Code. ` with the Florida Energy Code- Before BY: � Before construction is completed o 5 U j this building will be inspect DATE' compliance with Section 553.908 WS,�.�'� I hereby certify that this building, as designed, is in Florida Statutes- compliance with the Florida Energy Code. BUILDING OFFICIAL' OWNERIAGENT: DATE: r DATE: _ EnergyGauge®(Version: FLR1 PA 2.02) Aggressive Electric 9029 W. Beaver Street Jacksonville, FL 32221 Office(904)219-8733 /Fax: (904) 781-3373 FAX To: ;�vcR �antFrom: rZ Atte: �C'ync-\ t6g�c Date: la Fax: aLA'I - S%L.1 S Comments: MR. V IrA ?otaCnumber of jpages, includtng cover: FLOODPLAIN DEVELOPMENT INFORMATION Location:: Type of Development: f Flood Zone: Required Lowest Floor Elevation: — ' If building is located within a flood hazard zone, a survey must be made AFTER THE SLAB HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above the base flood elevation established for that zone. No final inspection will be made and no certificate of occupancy will be issued until the survey is on file with the Building Department. COMMENTS: Applicant Acknowledgment: I understand that the issuance of this permit is contingent upon the above information being correct and that the plans and supporting data have been or shall be provided as required. I agree to comply with all applicable provisions of Ordinance No. 25-7-11 and all other laws or ordinances affecting the proposed development. Date Applicant's Signature Department Use: Required Lowest Floor Elevation As Built Lowest Floor Elevation Survey Filed with Building Department Building Department Representative