Loading...
Permit 2014 Vela Norte Circle Y r� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 t r?i11 5 r Application Number . . . . . 10-00000671 Property Address 2014 VELA NORTE CIR Date 5/26/10 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . 6600 - Application desc------------------------------------------------------- CHANGE OUT 4 TON SYSTEM ----------------------------- Owner Contractor ------------------------ ------------------------ GOODMAN, _ _ _ __GOODMAN, GEORGE A. HUXHAM HEATING & AIR POST OFFICE BOX 377 2101 FLORIDA BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 ------------------------------------------- Permit (904) - ------------------------- 246-6721 MECHANICAL HVAC PERMIT Additional desc . . 4 TON CHANGE OUT Permit Fee . . . . 107 . 00 Plan Check Fee Issue Date . 00 Expiration Date . . 11/22/10 Valuation 0 ------------------------------------------------------ Special Notes and Comments ARI # 3514632 --------------------------------- Fee summary Char ed ----- g Paid Credited Due ---------- ---------- Permit Fee Total 107 . 00 107 . 00 Plan Check Total . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 • 00 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 oB ADDREss: X01 'lf�,, DdG (2- PERMFr# � PROJECT VALUE$ &6C(O�' [EW AIR CONDITIONING& HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity _ Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating- Duct Systems: Total CFM REOUFRED ►EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 3S1 Air Conditioning: Unit Quantity 1 Tons Per Unit RE ULI ZED Heat: Unit Quantity BTU's Per Unit Seer Rating 1 S Duct Systems: Total CFM REQUMED TU PREVENTION Fire Sprinkler System Quantity. (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) TIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators k,-LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Waxer Heaters Solar Collection Systems Tanks(gallons) Wells )THER: 'ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified r not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperly Owners Name l` /M lot✓L,) Phone Number � )C(-7 02 Ji Mechanical Company Allam ' /2(YN— Office Phone2j.-oFax_g!�L�7;> ;o. Address: 1Q - © r tti city Stater Zip W ,icense - Holder(Print): (fir E � State Certification/Registration# Notarized Signature of License Ho r and subscribed before 's LAMINA AlIitNME day 20 h) �►Pdft-VAN d of Notary Public • my Cestts.bon plot N.N1 emom Mt it�0 g111>t 1aaN N�MM anal ■ e , This combination qualifies for a Federal Energy t Efficiency Tax Credit when placed in service rg between Feb 17,2009 and Dec 31,2010. Certificate of Product Ratings AHRI Certified Reference Number: 3514632 Date: 5/26/2010 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number:4TWR5048E1 Indoor Unit Model Number:4TEE3F65B1 Manufacturer:TRANE Trade/Brand name:XR15 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2006 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 48000 EER Rating (Cooling): 12.50 SEER Rating(Cooling): 15.00 Heating Capacity(Btuh)@ 47 F: 46000 Region IV HSPF Rating(Heating): 8.50 Heating Capacity(Btuh)@ 17 F: 30200 A'following a rating indicates a voluntary rerate of previously published data,unless accompanied with a WAS which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at wwwahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified atwwwahridirectory.org,dick on "10' Air-Conditioning, 'Verify Certificate"link and enter the AHRI Certified Reference Number and the date on s1-' Heating,and was issued,which is listed above,and the Certificate No.,which is listed below. which the certificate Refrigeration Institute 2009 Air-Conditioning,Heating,anti Refrigeration Institute CERTIFICATE NO.: 129193473960001305