Loading...
363 Atlantic Blvd unit 11 peterbrook i I I i I Lv7P A � I a I { BUT i aaaroxe 4,OQ0 SF II ff syr 1 1 Ii 1 uRcwm„�: 1 �4 Il Starbucks approx:1,274 SF I SrnoothIe King � approx: 1,000 SF GoOdWUI approx:1,000 sq.ft. i I + -•----- ' ' Peterbrooke prox:750 k Suite 10 Subject Space 1 �, approx: 1,404 SF [p R �— Julia's approx: 837 SF 1 I � I Turtle Island Market .' a approx:1,750 SF a I w � i 7 Lollipop w a„ • Lane w I � P approx:2,000 SF o Rev i Total Image �a approx:rox: 1r 000 SF t 1 'I I °�`. Sticky Fingers R approx: 5,000 SF 3 Hush 1 .,, t approx-: 1,000 SPI �. Archway Framing approx:1,000 SF s» I ,• I I ' i I I cT 0109042 NOTES: G-8 I. THE DESIGN, FABRICATION AND CONSTRUCTION SHALL CONFORM TO THE FOLLOWING CODES I AND SPECIFICATIONS: THE 2007 FLORIDA BUILDING CODE, THE AMERICAN " AL OF STEEL CONSTRUCTION 9TH EDITION), THE STEEL CONSTRUCTION(MANUAL o I I rj-O I INSTITUTE OF ( I AMERICAN WELDING SOCIETY(AWS DI.I-04), THE AMERICAN CONCRETE INSTITUTE BUILDING • • • CODE REQUIREMENTS FOR STRUCTURAL CONCRETE(ACI 318-05), THE SPECIFICATIONS FOR 2-Q ALUMINUM STRUCTURES BY THE ALUMINUM ASSOCIATION(CURRENT EDITION). 11 2. STRUCTURAL STEEL REQUIREMENTS: PLATES, ROLLED SHAPES AND BARS SHALL 0 E B OR BETTER N D ��mox (<� BE ASTM A36(OR EQUAL), STANDARD PIPE SHALL BE ASTM A53, GRAD ( �`v • FY-35 KSI), STRUCTURAL TUBING SHALL BE ASTM A500, GRADE B(OR BETTER, FY=46 3 KSO, ALL BOLTED CONNECTIONS SHALL BE MADE WITH ASTM T A325 BOLTS(OR BETTER e� WITH FLAT WASHERS(UNLESS NOTED OTHERWISE), ALL FASTENERS TO BE NON-CORROSIVE, ALL STRUCTURAL STEEL SHALL BE SHOP PRIME COATED WITH A RUST INHIBITIVE PRIMER AND FINISH PAINTED AS APPROVED BY OWNER(SURFACE PREPARATION SHALL BE IN — FASTENER LOCATION(Tl'P) ACCORDANCE WITH THE MAUUFACTURER S RECOMMENDATIONS), FIELD CONNECTIONS AND (MINIMUM QUANTITY INDICATED, G) DAMAGED OR ABRADED AREAS OF PROTECTIVE COATING SHALL BE TOUCH UP PAINTED WITH 6 i COMPATIABLE MATERIAL, ALL STEEL SUBJECT TO DIRECT CONTACT WITH EARTH SHALL BE BITUMASTIC(OR EQUAL) COATED(IF NOT SUBJECT TO SUNLIGHT AND CARBOMASTIC(OR o FRONT ELEVATION EQUAL) COATED(IF SUBJECT TO SUNLIGHT) IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS, ALL WELDS SHALL BE MADE WITH E70XX ELECTRODES(OR EQUAL), ALL FIELD WELDS SHALL COMPLY WITH AWS CODE FOR PROCEDURES, APPEARANCE, AND QUALITY OF WELDS, ALL WELDERS AND WELDING PROCESSES SHALL BE QUALIFIED IN ACCORDANCE WITH AWS STANDARD QUALIFICATION PROCEDURES. 3. ALL FERROUS TO NONFERROUS SURFACES SHALL BE SEPARATED BY 3M#355 POLYESTER -os • CLEAR TAPE(OR EQUAL). 3 4. THE ELECTRICAL INSTALLATION SHALL BE IN COMPLIANCE WITH THE NATIONAL ELECTRICAL g s i CODE AND ALL REQUIREMENTS Of THE LOCAL GOVERNING AUTHORITY. � 0 'i 5. THE DESIGN WIND SPEED IS 120 MPH PER ASCE 7-05 WITH 'C' EXPOSURE RESULTING IN A 15 I DESIGN PRESSURE OF 45 PSF AT A HEIGHT OF 25'-0" ABOVE GRADE. j 6. THE CUSTOMERS BUILDING ENGINEER IS TO DETERMINE IF THE BUILDING STRUCTURE WILL 3 SUPPORT THE SIGN. THE CUSTOMER SHALL SUPPLY ANY ADDITIONAL STRUCTURE REQUIRED. 7. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD AND .� EXISTING STUD WALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES. WALL SECTION PER QUALITY SIGN SURVEY. s O"(MAX) (RESPONSIBILITY OF OTHERS) 8. ENGINEERING SEAL IS APPLICABLE TO THE MOUNTING PLATE/WALL ATTACHMENT DESIGN ONLY. � 21'x 2"x J-" STEEL ANGLE 4 9. ALL ELECTRICAL COMPONENTS ARE UL LISTED. SIGNAGE IS MANUFACTURED IN COMPLIANCE NECLOCKING CONTINUOUS 600. SIGNAGE IS GROUNDED IN COMPLIANCE WITH NEC 250. ONE VISIBLE 20 AMP i ( ACROSS ADJACENT STUDS DISCONNECT IS REQUIRED PER CIRCUIT. I N I PER FASTENER)(TYP) 10. MAXIMUM SIGN HEIGHT IS 25'-0' ABOVE GRADE. o � I REFERENCE FRONT 8 -1"O A3G THREADED RODS WITH ELEVATION FLAT WASHERS, LOCK WASHERS, AND NUTS(REFERENCE FRONT ELEVATION I QUALITY SIGN COMPANY MINIMUM UANTITY(TYP) Glenn T. Tisdale P.E. 5160 SUNBEAM ROAD JACKSONVILLE FL 32257 WALL CABINET PETERBROOKE- ATLANTIC BEACH, FL SIGN CABINET �- , CAD: GT SCALE: 3/8" = I' SECTION DETAIL DATE: 10/19/09 designFirst, Inc. N.T.S. SHT. NO.: I OF I P.O. BOX 9335 DWG. NO.: 0109042SI DOTHAN,AL 36304 (334)793-9734 t i ONE('1)'SET OF PUSH-THRU, ITERS ON BACKGROUND CAB, I I "Sign 677 5160 Sunbeam had 6"deep alum.cabinet Jacksonville,FL 32257 16'-8"oAl r. / (800)772-7446/(904)2684681 acrylic flange Fox(404)268.4681 — 15'-0"cab. fluorescent lamps www.qualifysigncompony.com 3/4"acrylic push-thru Peterbrooke power supply I N N 363 ATLANTIC BLVD. / ATLANTIC KH.FL 32133 sheathing I l stucco facade I wood stud Proied Name 1"thick sintra NSH THRU LETTERS ON /2"thick sintra /�"sutra pineapple � BACKGROUND CABINET 1"sintra half-circleJ Project Title i Front Elevation Display Square Footage: 33.3 framing PTB 112-00 ' 3/$" = 1'-0" 3/8"lag screw r L Conrad: SETH JOYNE R 2 Side Elevation not to scale Salesperson: i JANE NOWTHY I I ns• cificati© : Designer: I REMOVE EXISTING PANEL SIGN. AS A BACKGROUND CABINET ALL ONE 1 SET OF PUSH-THRU LETTERS ON _ i MANUFACTURE AND INET CABINET.................ONE (1)6" DEEP ALUMINUM FABRICATED CABINET PAINTED LOW GLOSS PMS REFLEX BLUE GRAPHICS..............PINEAPPLE SHAPES TO BE'/z"THICK SINTRA, PAINTED PMS 3425 LOW GLOSS AND Design Dote MOUNTED FLUSH TO 1"THICK WHITE SINTRA HALF-CIRCLE, MOUNTED TO SIDES OF -25-0! CABINET I LETTERS.................ONE(1)SET OF CLEAR ACRYLIC PUSH THRU LETTERS WITH WHITE TRANSLUCENT Revisions COMPUTER CUT GRAPHICS APPLIED 1ST SURFACE ILLUMINATION. .00.00 .......HIGH OUT PUT FLUORESCENT LAMPS O4� M j INSTALLATION........CABINET TO BE MOUNTED FLUSH TO BUILDING FACADE NEXT DOOR TO GOODWILL IN CUSTOMER DESIGNATED LOCATION I I I , i COLOR LEGEND Photo Overlay ■ PMS REFLEX BLUE LOW GLOSS 3 not to scale PMS 3425 LOW GLOSS I ■ I 3630-20,WHITE WHITE SINTRA File Name/Location ii (J:�CYtiblRfrf�Mllt�rrMl[! ChocoWlkr/rTR 112-MAdr I P.01 Customer F,pproval ate THIS DESIGN IS THE SOLE PROPERTY OF DUALITY SIGN AND MAY NOT BE USED OR DUPLICATED IN ANY FORM WITHOUT THE EXPRESSED WRITTEN PERMISSION OF QUALITY SIGN. �i ¢ ; I