Permit 2226 Beachcomber TrailCITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5826
Application Number 10-00000832 Date 6/30/10
Property Address 2226 BEACHCOMBER TR
Application type description MECHANICAL HVAC ONLY
Property Zoning TO BE UPDATED
Application valuation 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
Owner
------------------------
WALTERS, ROBERT M.
2226 BEACHCOMBER TRAIL
ATLANTIC BEACH FL 32233
Contractor
------------------------
HUXHAM HEATING & AIR
2101 FLORIDA BLVD.
NEPTUNE BEACH FL 32266
(904) 246-6721
Permit MECHANICAL HVAC PERMIT
Additional desc .
Permit Fee 99.00 Plan Check Fee .00
Issue Date Valuation 0
Expiration Date
--------- 12/27/10
--------------
Fee summary
----------------- --------------
Charged
-- ---------------------------------------
Paid Credited Due
Permit Fee Total -------- -
99.00 --------- -------
99.00 --- ----------
.00 .00
Plan Check Total .00 ,00 .00 .00
Grand Total 99.00 99.00 .00 .00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL ~'ERMIT APPLICATION
CITY OF ATLANTIC 13EACT~I
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
Jos ADDRESS: ;l ~o~~ ~4s~~ corr-,~~sZ l VZ • P~R1I~IIT #
Oa
P~tOJECT I~'AL UE $ S 3 ! C7
NEW AIR CONDITIONING ~ HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rati_ng_
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING ~ HEATING SYSTEM INS 3S 9I?075
Air Conditioning: Unit Quantity Z Tons Per Unit ,3 REQUIRED
Heat: Unit Quantity l BTU's Per Unit ~ 000 Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fixe Sprinkler System Quantity.
Fire Standpipe Quantity
Underground Fire Main Value
Fire Hose Cabinets Quantity
Commercial Hoods Quantity
Fire Suppression Systems Quantity
(Requires 3 sets of plans}
(Requires 3 sets of plans)
(Requires 3 sets of glans)
(Requires 3 sets of plans)
(Requires 3 sets of plans}
(Requires 3 sets of plans)
FIl2E PLACES
Prefabricated Fireplace Qty
Gas Piping Outlets
ALL OTHER. GAS PIPING
.Quantity of Outlets
# Vented Wall Furnaces
# Water Heaters
OTHER:
MISCELLANEOUS:
Automobile Lifts
Bailers BTU's
Elevators/Escalators
Heat Exchanger
Pumps
Refrigerator Condenser BTU's
Solar Collection Systems
Tanks (gallons)
Wells
Permit becomes void if work does not commence within. a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or nat.. The permit does nat give aut//ho~~rit~~y to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name t.C/~' %~-~~ 2 S Phone Number of ~t 7 ~ 1 S~ Y
Mechanical Conmpany J`7U~1'}yigv~ -J~~~ ~~~'L, Office Phonea_~~~Fax d~~/G^~~3?~
Co. Address: ~ ~ a ~ ~f 0 2<<o?r~ 1L7~~ City ~~'~.~. ~-aC,~'~ State ~ zip-'a~66
License Holder (Print}: 4. ~ ~ ~ 4.~~
1V~at~arazec~~eg~aca~e~~°~ ~f ~ric~~.~~~~A~~~
S om sobscribed before
"",•,,~,,,• NnR~ A06~E-0oYwrM~ afore of Notary Public
3s Notuy P~Ne - SqN o! Ho~Ni
s • IN~r Cow. E~ir~ Oq i!. !01!
Co~aMtMM N I10 ifOfit
lonU/ 1MwiM NwIMM MIMH1 MM.
State Certification/Registration # ~'tgGO,~7Ff).s
~ day
20
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
between Feb 17, 2009 and Dec 31, 2010.
Certificate of Product Ratings
AHRI Certified Reference Number: 3519775 Date: 6/30/2010
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 4TWR5036E1
Indoor Unit Model Number: 4TEE3F39A1
Manufacturer: TRANE
TradelBrand name: XR15 WEATHERTRON
Manufacturer responsible for the rating of this system combination is TRANE
Rated as follows in accordance with AHRI Standard 210/240-2006 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh): 36000
EER Rating (Cooling): 13.00
SEER Rating (Cooling): 15.00
Heating Capacity(Btuh) @ 47 F: 34000
Region IV HSPF Rating (Heating): 9.00
Heating Capacity(Btuh) @ 17 F: 23600
A ` following a rating indicates a voluntary rerate of previously published data, unless accompanied with a WAS which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the produd(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the produd{s) listed on this Certificate. AHRI expressly disdaims all liabil'iiy for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridiredory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The
contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form
or manner or by any means, except for the user's individual, personal and confidential reference.
CERTIFICATE VERIFICATION A ~,,,~, Air-Conditioning,
The information for the model cited on this certificate can be verified at www.ahridirectoryorg, dick on A~ ®!~ r® Heating, and
Refrigeration Institute
°Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate
was issued, which is listed above, and the Certificate No., which is fisted below.
2009 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129223747407322785