Loading...
Permit 620 Beach Avenue (2) R FORM 600A-2004 FILE COPY EnergyGaugeO 4.0 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name. Dean Davis-Barker Builder: Dean Davis Address: 620 Beach Ave Permitting Office: Atlantic Beach City, State: Atlantic Beach, FL 32233- Permit Number: Owner: Barker Residence Jurisdiction Number: Climate Zone: North 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family - a. Central Unit Cap:40.0 kBtu/hr _ 3. Number of units,if multi-family 4 _ SEER: 13.00 _ i 4. Number of Bedrooms 6 _ b. Central Unit Cap:40.0 kBtu/hr 5. Is this a worst case? Yes _ SEER: 13.00 _ 6. Conditioned floor area(ftz) 6015 ft2 _ c. 2 Others(See details) Additional Cap:50.6 kBtu/hr _ 7. Glass type and area:(Label reqd.by 13-104.4.5 if not default) _ a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a.(Dble Default)376.0 ft2 -. a. Electric Heat Pump Cap:37.2 kBtu/hr _ ,. SHGC: HSPF:8.10 - (or Clear or Tint DEFAULT) 7b. (Clear)376.0 ft2 - b. Electric Heat Pump Cap:37.2 kBtu/hr 8. Floor types HSPF:7.70 _ a. Slab-On-Grade Edge Insulation R=0.0,336.0(p)ft _. c. 2 Others(See details) Additional Cap:47.2 kBtu/hr s b. Raised Wood,Post or Pier R=19.0, 1036.0ftz - _ c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 50.0 gallons _ a. Frame,Wood,Exterior R=19.0,4994.0 ft' _ EF:0.92 b. N/A - j b. Electric Resistance Cap:50.0 gallons _ c. N/A _ EF:0.92 d. N/A _ c. Conservation credits _ e. NIA _ (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0,4237.0 ft2 15. HVAC credits _ b.NIA _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret: Unc. AH:Garage Sup.R=6.0,25.0 ft2 MZ-C-Multizone cooling, b. 3 Others 75.0 ft _ MZ-H-Multizone heating) Total as-built points: 71793 Glass/Floor Area: 0.23 PASS Total base points: 78154 I hereby certify thaii,ttle plaa;s- ztiran_ :Lid b_y Review of the plans and IgE sTq� this calculation are in com i ' h t Florid aercrc�'' specifications covered by this �o _ Code. calculation indicates compliance PREPARED Y: /may 9C j with the Florida Energy Code. DATE: kBefore construction is completed ;d - r1i a this building will be inspected for g, designe in compliance compliance with Section 553.908 A-iereby certify that thi with the Florida Energy Code Florida Statutes. oD WE OWNER/ EF: BUILDING OFFICIAL: IATE:I o w DATE: sdominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pages 2&4. EnergyGauge®(Version: FLRCSB v4.0) i FORM 60OA-2004 EnergyGauge® 4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 620 Beach Ave, Atlantic Beach, FL,32233- PERMIT #: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 6015.0 20.04 21697.3 Double,Clear E 8.0 6.0 25.0 42.06 0.45 476.9 Double,Clear E 8.0 9.0 48.0 42.06 0.55 1101.0 Double,Clear N 8.0 6.0 30.0 19.20 0.67 385.3 Double,Clear N 8.0 9.0 48.0 1920 0.73 671.1 Double,Clear W 8.0 6.0 15.0 38.52 0.47 270.8 Double,Clear E 2.0 6.0 15.0 42.06 0.85 536.7 Double,Clear S 4.0 6.0 60.0 35.87 0.59 1267.5 Double,Clear N 2.0 6.0 25.0 19.20 0.90 432.8 Double,Clear S 14.0 6.0 60.0 35.87 0.44 952.4 Double,Clear S 14.0 9.0 96.0 35.87 0.47 1615.7 Double,Clear N 8.0 6.0 30.0 19.20 0.67 385.3 Double,Clear N 6.0 6.0 60.0 19.20 0.71 819.0 Double,Clear N 6.0 6.0 60.0 19.20 0.71 819.0 Double,Clear S 2.0 3.0 4.0 35.87 0.59 84.5 Double,Clear E 8.0 6.0 15.0 42.06 0.45 286.1 Double,Clear E 8.0 9.0 48.0 42.06 0.55 1101.0 Double,Clear N 6.0 6.0 60.0 19.20 0.71 819.0 Double,Clear W 6.0 9.0 24.0 38.52 0.64 588.9 Double,Clear E 8.0 4.0 12.0 42.06 0.39 198.0 Double,Clear S 2.0 6.0 15.0 35.87 0.78 419.2 Double,Clear E 2.0 6.0 15.0 42.06 0.85 536.7 Double,Clear E 2.0 5.0 16.0 42.06 0.80 536.3 Double,Clear S 2.0 5.0 32.0 35.87 0.72 830.3 Double,Clear S 2.0 6.0 30.0 35.87 0.78 838.3 Double,Clear S 2.0 6.0 30.0 35.87 0.78 838.3 Double,Clear S 2.0 5.0 16.0 35.87 0.72 415.2 Double,Clear S 2.0 4.0 6.0 35.87 0.66 142.0 Double,Clear N 2.0 6.0 30.0 19.20 0.90 519.3 Double,Clear N 2.0 3.0 4.0 19.20 0.78 59.7 Double,Clear N 2.0 6.0 30.0 19.20 0.90 519.3 Double,Clear W 2.0 4.0 9.0 38.52 0.73 253.1 Double,Clear S 8.0 6.0 35.0 35.87 0.48 607.9 Double,Clear S 8.0 9.0 48.0 35.87 0.54 923.3 Double,Clear E 2.0 6.0 30.0 42.06 0.85 1073.5 Double,Clear E 4.0 9.0 40.0 42.06 0.77 1290.5 Double,Clear W 2.0 6.0 30.0 38.52 0.85 984.7 Double,Clear W 2.0 9.0 96.0 38.52 0.93 3457.3 Double,Clear N 2.0 6.0 30.0 19.20 0.90 519.3 Double,Clear W 2.0 6.0 15.0 38.52 0.85 492.3 Double,Clear S 2.0 6.0 30.0 35.87 0.78 838.3 EnergyGauge®DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge®4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 620 Beach Ave, Atlantic Beach, FL,32233- PERMIT #: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF= Points Double,Clear S 2.0 4.0 9.0 35.67 0.66 213.0 Double,Clear E 2.0 6.0 30.0 42.06 0.85 1073.5 Double,Clear S 2.0 6.0 15.0 35.87 0.78 419.2 As-Built Total: 1376.0 30611.4 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Allacent 0.0 0.00 0.0 Frame,Wood,Exterior 19.0 4994.0 0.90 4494.6 Exterior 4994.0 1.70 8489.8 Base Total: 4994.0 8489.8 As-Built Total: 4994.0 4494.6 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points „Adjacent 0.0 0.00 0.0 Exterior Wood 120.0 6.10 732.0 Exterior 120.0 6.10 732.0 Base Total: 120.0 732.0 As-Built Total: 120.0 732.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM= Points Under Attic 4236.5 1.73 7329.1 Under Attic 30.0 4237.0 1.73 X 1.00 7330.0 Base Total: 4236.5 7329.1 As-Built Total: 4237.0 7330.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 336.0(p) -37.0 -12432.0 Slab-On-Grade Edge Insulation 0.0 336.0(p -41.20 -13843.2 Raised 1036.0 -3.99 -4133.6 Raised Wood,Post or Pier 19.0 1036.0 0.77 793.6 Base Total: -16565.6 As-Built Total: 1372.0 -13049.6 INFILTRATION Area X BSPM = Points Area X SPM = Points 6015.0 10.21 61413.1 6015.0 10.21 61413.1 EnergyGaugeODCA Form 60OA-2004 EnergyGaugefflaRES2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 SUMMER CALCULATIONS y Residential Whole Building Performance Method A - Details ADDRESS: 620 Beach Ave,Atlantic Beach, FL,32233- PERMIT#: BASE AS-BUILT Summer Base Points: 83095.8 Summer As-Built Points: 91531,5 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Central Unit 40000 btuh,SEER/EFF(13.0)Ducts:Unc(S),Unc(R),Gar(AH),R6.0(INS) 91531 0.31 (1.09 x 1.147 x 0.95) 0.263 1.000 8151.6 (sys 2:Central Unit 22800 btuh,SEER/EFF(13.0)Ducts:Unc(S),Unc(R),int(AH),R6,0(INS) 91531 0.17 (1.09 x 1.147 x 0.86) 0.263 1.000 4646.4 (sys 3:Central Unit 40000 btuh,SEER/EFF(13.0)Ducts:Unc(S),Unc(R),Int(AH),R6.0(INS) 91531 0.31 (1.09 x 1.147 x 0.86) 0.263 1.000 8151.6 (sys 4:Central Unit 27800 btuh,SEER/EFF(13.0)Ducts:Unc(S),Unc(R),Int(AH),86.0(INS) 91531 0.21 (1.09 x 1.147 x 0.86) 0.263 1.000 5665.4 83095.8 0.4266 35448.7 91531.5 1.00 1.108 0.263 1.000 26615.0 EnergyGaugeTP^DCA Form 60OA-2004 EnergyGauge®/FlaRE52004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 620 Beach Ave, Atlantic Beach, FL, 32233- PERMIT #: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF= Point .18 6015.0 12.74 13793.6 Double,Clear E 8.0 6.0 25.0 18.79 1.36 639.5 Double,Clear E 8.0 9.0 48.0 18.79 1.26 1132.6 Double, Clear N 8.0 6.0 30.0 24.58 1.02 753.2 Double,Clear N 8.0 9.0 48.0 24.58 1.02 1199.7 Double,Clear W 8.0 6.0 15.0 20.73 1.20 371.6 Double, Clear E 2.0 6.0 15.0 18.79 1.06 298.7 Double,Clear S 4.0 6.0 60.0 13.30 2.07 1654.0 - Double,Clear N 2tr 6.0 25.0 24.58 1.00 617.3 Double, Clear S 14.0 6.0 60.0 13.30 3.57 2851.8 Double,Clear S 14.0 9.0 96.0 13.30 3.32 4238.8 Double,Clear N 8.0 6.0 30.0 24.58 1.02 753.2 Double,Clear N 6.0 6.0 60.0 24.58 1.02 1501.6 Double,Clear N 6.0 6.0 60.0 24.58 1.02 1501.6 Double,Clear S 2.0 3.0 4.0 13.30 2.07 110.3 Double,Clear E 8.0 6.0 15.0 18.79 1.36 383.7 Double,Clear E 8.0 9.0 48.0 18.79 1.26 1132.6 Double,Clear N 6.0 6.0 60.0 24.58 1.02 1501.6 Double,Clear W 6.0 9.0 24.0 20.73 1.12 557,3 Double,Clear E 8.0 4.0 12.0 18.79 1.45 326.9 Double,Clear S 2.0 6.0 15.0 13.30 1.25 249.8 Double;Clear E 2.0 6.0 15.0 18.79 1.06 298.7 Double,Clear E 2.0 5.0 16.0 18.79 1.08 325.8 Double,Clear S 2.0 5.0 32.0 13.30 1.40 595.8 Double,Clear S 2.0 6.0 30.0 13.30 1.25 499.6 Double,Clear S 2.0 6.0 30.0 13.30 1.25 499.6 Double,Clear S 2.0 5.0 16.0 13.30 1.40 297.9 Double,Clear S 2.0 4.0 6.0 13.30 1.64 130.8 Double,Clear N 2.0 6.0 30.0 24.58 1.00 740.7 Double,Clear N 2.0 3.0 4.0 24.58 1.01 99.6 Double,Clear N 2.0 6.0 30.0 24.58 1.00 740.7 Double,Clear W 2.0 4.0 9.0 20.73 1.08 202.2 Double,Clear S 8.0 6.0 35.0 13.30 3.15 1464.6 Double,Clear S 8.0 9.0 48.0 13.30 2.55 1629.0 Double,Clear E 2.0 6.0 30.0 18.79 1.06 597.3 Double,Clear E 4.0 9.0 40.0 18.79 1.10 825.2 Double,Clear W 2.0 6.0 30.0 20.73 1.04 647.9 Double,Clear W 2.0 9.0 96.0 20.73 1.02 2024.8 Double,Clear N 2.0 6.0 30.0 24.58 1.00 740.7 Double,Clear W 2.0 6.0 15.0 20.73 1.04 324.0 Double,Clear S 2.0 6.0 30.0 13.30 1.25 499.6 EnergyGauge®DCA Form 60OA-2004 EnergyGau9e@)/FIaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge®4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 620 Beach Ave, Atlantic Beach, FL,32233- PERMIT #: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF= Point Double,Clear S 2.0 4.0 9.0 13.30 1.64 196.2 Double,Clear E 2.0 6.0 30.0 18.79 1.06 597.3 Double,Clear S 2.0 6.0 15.0 13.30 1.25 249.8 As-Built Total: 1376.0 36003.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 Frame,Wood,Exterior 19.0 4994.0 2.20 10986.8 Exterior 4994.0 3.70 18477.8 Base Total: 4994.0 18477.8 As-Built Total: 4994.0 10986.8 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 120.0 12.30 1476.0 Exterior 120.0 12.30 1476.0 Base Total: 120.0 1476.0 As-Built Total: 120.0 1476.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 4236.5 2.05 8684.8 Under Attic 30.0 4237.0 2.05 X 1.00 8685.8 Base Total: 4236.5 8684.8 As-Built Total: 4237.0 8685.8 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 336.0(p) 8.9 2990.4 Slab-On-Grade Edge Insulation 0.0 336.0(p 18.80 6316.8 Raised 1036.0 0.96 994.6 Raised Wood,Post or Pier 19.0 1036.0 0.88 907.5 Base Total: 3985.0 As-Built Total: 1372.0 7224.3 INFILTRATION Area X BWPM = Points Area X WPM = Points 6015.0 -0.59 -3548.8 6015.0 -0.59 -3548.8 EnergyGauge®DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 = FORM 60OA-2004 EnergyGauge® 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 620 Beach Ave, Atlantic Beach, FL, 32233- PERMIT #: BASE AS-BUILT Winter Base Points: 42868.3 Winter As-Built Points: 60827.9 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 37200 btuh,EFF(8.1) Ducts:Unc(S),Unc(R),Gar(AH),R6.0 60827.9 0.306 (1.069 x 1.169 x 0.95) 0.421 1.000 8812.0 (sys 2:Electric Heat Pump 21200 btuh,EFF(7.7)Ducts:Unc(S),Unc(R),Int(AH),R6.0 60827.9 0.174 (1.069 x 1.169 x 0.88) 0.443 1.000 5282.8 (sys 3:Electric Heat Pump 37200 btuh,EFF(8.1) Ducts:Unc(S),Unc(R),Int(AH),R6.0 60827.9 0.306 (1.069 x 1.169 x 0.88) 0.421 1.000 8812.0 (sys 4:Electric Heat Pump 26000 btuh,EFF(7.7)Ducts:Unc(S),Unc(R),Int(AH),R6.0 60827.9 0.214 (1.069 x 1.169 x 0.88) 0.443 1.000 6478.9 42868.3 0.6274 26895.6 60827.9 1.00 1.125 0.429 1.000 29367.9 EnergyGaugeTm DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge®4.0 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 620 Beach Ave,Atlantic Beach, FL, 32233- PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 6 2635.00 15810.0 50.0 0.92 6 0.50 2635.00 1.00 7905.0 50.0 0.92 6 0.50 2635.00 1.00 7905.0 As-Built Total: 15810.0 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 35449 26896 15810 78154 1 26615 29368 15810 71793 PASS ��4TZiE ST9TFp EnergyGaugeTm DCA Form 60OA-2004 EnergyGauge®/FlaRES2004 FLRCSB v4.0 FORM 600A-2004 EnergyGauge®4.0 w Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 620 Beach Ave, Atlantic Beach, FL, 32233- PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows&Doors _ 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft.window area;.5 cfm/sq.ft.door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners; utility penetrations;between wall panels&top/bottom plates;between walls and floor. EXCEPTION:Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to,the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter,penetrations and seams. _ Geilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases j soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access. EXCEPTION:Frame ceilings where a continuous infiltration barrier is installed that is sealed at theperimeter,at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Multi story Houses_ __ 606 1.ABC_1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 I Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES_(must be met or exceeded by all residences.) COMPONENTS SECTION I REQUIREMENTS CHECK Water Heaters 1 612.1 1 Comply with efficiency requirements in Table 612.1.ABC.3.2.Switch or clearly marked cir -----— -- breake"electric�_or cutoff�gas1_must beprovided External or built-in heat trap required. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools I must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficiency of 78%. Shower heads 1612.1 Water flow must be restricted to no more than 25gallons Per minute at 80 PSIG. Air Distribution Systems 610.1 1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically / I / attached,sealed,insulated,and installed in accordance with the criteria of Section 610. V/ Ducts in oned attics: HVAC Controls 607.1 _ I Separate readily accessible manual oautomatic thermostat for each system. Insulation 604.1,602.1 Ceilings-Min. R-19.Common walls-Frame R-11 or CBS R-3 both sides. — Common ceiling&floors R-11. EnergyGaugeTm DCA Form 60OA-2004 EnergyGauge0/FlaRES'2004 FLRCSB v4.0 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE*= 84.5 The higher the score,the more efficient the home. Barker Residence, 620 Beach Ave, Atlantic Beach, FL, 32233- 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap:40.0 kBtu/hr _ 3. Number of units,if multi-family 4 - SEER: 13.00 4. Number of Bedrooms 6 _ b. Central Unit Cap:40.0 kBtu/hr - 5. Is this a worst case? Yes _ SEER: 13.00 _ 6. Conditioned floor area(ft2) 6015 ft _ c. 2 Others Cap:50.6 kBtu/hr _ 7. Glass type and area:(Label reqd.by 13-104.4.5 if not default) ` a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a.(Dble Default)376.0 ft2 _ a. Electric Heat Pump Cap:37.2 kBtu/hr , b. SHGC: HSPF:8.10 _ (or Clear or Tint DEFAULT) 7b. (Clear)376.0 ft2 - b. Electric Heat Pump Cap:37.2 kl3tu/hr _ 8. Floor types HSPF:7.70 _ a. Slab-On-Grade Edge Insulation R=0.0,336.0(p)ft _ c. 2 Others Cap:47.2 kBtu/hr _ b. Raised Wood,Post or Pier R=19.0,I036.0ft2 _ ` c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:50.0 gallons _ _ a. Frame,Wood,Exterior R=19.0,4994.0 ft2 _. EF:0.92 _ b. N/A _ b. Electric Resistance Cap:50.0 gallons _ c. N/A _ EF:0.92 d. N/A _ c. Conservation credits e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0,4237.0 ft2 _ 15. HVAC credits _ b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Garage Sup.R=6.0,25.0 ft2 _ MZ-C-Multizone cooling, b. 3 Others 75.0 ft _ MZ-H-Multizone heating) 1 certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed(or exceeded) 04T11E STgT� in this home before fin inspec ' .Otherwise,a new EPL Display Card will be completed based on installed de o tan features. Builder Signature' Date: d6 i1 a m Address of New Home: City/FL Zip: j�G0D4`'�J *NOTE: The home's estimated energy performance score is only available through the FLA/RES computer program. This is not a Building Energy Rating.If your score is 80 or greater(or 86 for a US EPA/DOE EnergyStarTudesignation), your home may yualify for energy efficiency mortgage(EEM)incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucfedu for information and a list of certified Raters.For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type.For actual glass type and areas see Summer&Winter Glass output onages 2&4. KnergyGauge®(Version: FLRC0 v4.0) Barker Residence HVAC Load Calculations for Dean Davis 1901 1st Street North Jacksonville Beach, FL 32250 it Ik - FZgSIDZN.nAh. i RHVACHVAC LOADS I� I e ared By: Gle n - cean State Heati g and Air Conditioning 1476 lantic Blvd. Neptune ach, FL 32266 )249-8251 Friday,January 06,2006 I + I Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Ocean State Htg&A/C Barker Residence Neptune Beach, FL 32266-1798 page 2 Project Report- - General Project Information Project Filename: C:\Elite\Rhvacw\Projects\Owner-Builders\Dean Davis-Barker.rhv Project Title: Barker Residence Designed By: Ocean State Heating &Air Conditioning Project Date: Thursday, January 05, 2006 Client Name: Dean Davis Client Address: 1901 1st Street North Client City: Jacksonville Beach, FL 32250 Client Phone: 237-2222 Client Fax: 247-6513 Company Name: Ocean State Heating and Air Conditioning Company Representative: Glenn Jones Company Address: 1476 Atlantic Blvd. Company City: Neptune Beach, FL 32266 Company Phone: (904)249-8251 Company Fax: (904)249-8949 Company Comment: Design Data --- Reterence City: Jacksonville, Florida Daily Temperature Range: Medium Latitude: 30 Degrees Elevation: 26 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: 32 0 0 72 0 Summer: 94 77 50 75 48 Check Figures Total Building Supply CFM: 4,148 (4.1 AC/hr) CFM Per Square ft.: 0.690 Square ft. of Room Area: 6,016 Square ft. Per Ton: 610 Building Loads Total Heating Required With Outside Air: 119,213 Btuh 119.213 MBH Total Sensible Gain: 91,172 Btuh 84 % Total Latent Gain: 17,033 Btuh 16 % Total Cooling Required With Outside Air: 108,205 Btuh 9.02 Tons (Based On Sensible+ Latent) 9.87 Tons (Based On 77%Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. ----------- All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. — C.:.1n.. 0-f)A ARA Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Ocean State Htg&A/C Barker Residence a Neptune Beach,FL 32266-1798 Page 3 Load Preview Report -- Sens Lat Net Sens Win Sum Ad' - Sys Duct j ' Scope Area Gain Gam Gain Loss CFM CFM CFM CFM Size Building. 9.02_Net Tons, 9.87 Recommended Tons, 610 ft.z/Ton, 119.21 MBH HeatinD - Building 6,016 91,172 17,033 108,205 119,213 1,550 4,148 4,148 System 1:2.7.2_ Net Tons, 3.08 Recommended Tons, 584 ft.21Ton, 42.87 MBH Heating System 1 1,800 28,496 4,176 32,672 42,865 557 1,296 1,296 20 Zone 1 1,800 28,496 4,176 32,672 42,865 557 1,296 1,296 1-Dining 304 5,965 1,032 6,997 8,958 116 271 285 271 3-6 2-Pantry 150 493 149 642 1,163 15 22 22 22 1-4 3-Kitchen 208 6,123 466 6,589 4,880 63 279 348 279 3-6 4-Powder 64 2,221 155 2,376 2,615 34 101 106 101 1-6 5-Family Room 891 6,654 1,305 7,959 13,490 175 303 378 303 4-6 6-Entry 119 6,208 1,044 7,252 9,585 125 282 297 282 3-6 7-Pool Bath 64 832 25 857 2,174 28 38 38 38 1-4 � System 2 1.70 Net Tons, _ 1 85 Recommended Tons,. _585 ft.z/Ton18 49 MBH Heatii�_ _- System 2 1,083 17,116 3,278 20,394 18,488 240 779 779 16 j Zone 1 1,083 17,116 3,278 20,394 18,488 240 779 779 8-Master Bedroom 358 6,808 1,758 8,566 9,099 118 310 418 310 4-6 9-W.I.C. 260 925 106 1,031 1,309 17 42 49 42 1-4 10-W.C. 72 2,013 265 2,278 2,309 30 92 92 92 1-6 11-Master Bath 225 3,994 424 4,418 3,581 47 182 227 182 2-6 12-Office 168 3,376 725 4,101 2,190 28 154 192 154 2-6 -System 3: 2.67 Net Tons, 2.79 Recommended Tons, 727 ft.2/Ton, 32.24 MBH Heating - - System 3 2,032 25,822 6,263 32,085 32,238 419 1,175 1,175 20 Zone 1 2,032 25,822 6,263 32,085 32,238 419 1,175 1,175 -13-Kitty 336 5,874 1,438 7,312 6,162 80 267 334 267 3-6 14-Hall 162 0 0 0 0 0 0 0 0 0-0' 15-Laundry 162 1,877 128 2,005 1,114 14 85 85 85 1-5 16-Trevor 336 4,973 1,183 6,156 5,254 68 226 226 226 2-6 17-Colin 336 5,294 1,289 6,583 6,574 85 241 241 241 2-7 18-Rec Room 700 7,804 2,225 10,029 13,134 171 355 444 355 4-6 System 4_1.92 Net Tons, 2.14 Recommended Tons, 515 ft.2/Ton, 25.62 MBH Heating System 4 1,101 191738 3,316 23,054 25,622 333 898 898 18 j Zone 1 1,101 19,738 3,316 23,054 25,622 333 898 898 19-Family 391 6,734 1,345 8,079 11,845 154 306 306 306 3-6 20-Kitchen 221 4,718 371 5,089 4,503 59 215 215 215 2-6 21-Bedroom 2 195 4,056 769 4,825 4,167 54 185 231 185 2-6 22-Bath 91 864 62 926 928 12 39 49 39 1-4 23-Bedroom 1 203 3,366 769 4,135 4,179 54 153 181 153 2-6 i Fririnw .lani mr%/09 9nni; R-n4 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Ocean State Htg&A/C Barker Residence " Neptune Beach, FL 32266-1798 - - -- - -- Page 4 Tota/Bui/ding► Summary Loads - Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 968 28,072 0 38,047 38-,047-- 9G 8,0479G French Door Double Clear Glass Wood Frame 408 8,517 0 10,610 10,610 10D Door Wood Solid Core 120 2,209 0 1,249 1,249 12H Wall R-19+ 1/2" Gypsum Board(R-0.5) 4994 11,985 0 6,771 6,771 16G Ceiling Under Vent. Attic - R-30 Insulation 4237 5,594 0 6,013 6,013 201 Floor Over Open Crawl Carpet+ R-19 1036 1,989 0 696 696 22A Slab on Grade No Edge Insulation 336 10,886 0 0 0 Subtotals for structure: 69,252 0 63,386 63,386 People: 16 3,680 4,800 8,480 Equipment: 0 4,200 4,200 Lighting: 0 0 0 Ductwork: 9,514 0 10,246 10,246 Infiltration: Winter CFM: 920, Summer CFM: 409 40,447 13,353 8,540 21,893 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Sensible Gain Total: 91,172 Temperature Swing Multiplier: X 1.00 Total Building Load Totals: 119,213 17,033 91,172 108,205 Check_Fi_gures Total Building Supply CFM: 4,148 (4.1 AC/hr) CFM Per Square ft.. 0.690 Square ft. of Room Area: 6,016 Square ft. Per Ton: 610 Building Loads Total Heating Required With Outside Air: 119,213 Btuh 119.213 MBH 'Total Sensible Gain: 91,172 Btuh 84 % Total Latent Gain: 17,033 Btuh 16 % Total Cooling Required With Outside Air: 108,205 Btuh 9.02 Tons (Based On Sensible + Latent) 9.87 Tons (Based On 77%Sensible Capacity) rNotes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. - .-.- .-. •- ,•-• .. • - __ n_-_ n_..:_ n_..i._.. .b... Crirlov lone iori nC. �nnF a•nd ��/t Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Ocean State Htg&A/C Barker Residence Neptune Beach, FL 32266-1798 - - Page 5 System l Summary L oads Component Area Sen Lat Sen Total Description Ouan Loss Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 384 11,136 0 12,649 12,649 9G French Door Double Clear Glass Wood Frame 192 4,008 0 5,034 5,034 10D Door Wood Solid Core 96 1,767 0 999 999 12H Wall R-19+ 1/2" Gypsum Board(R-0.5) 1838 4,411 0 2,492 2,492 16G Ceiling Under Vent. Attic- R-30 Insulation 183 241 0 260 260 22A Slab on Grade No Edge Insulation 204 6,610 0 0 0 Subtotals for structure: 28,173 0 21,434 21,434 People: 0 0 0 0 Equipment: 0 1,800 1,800 Lighting: 0 0 0 Ductwork: 2,041 0 2,591 2,591 Infiltration: Winter CFM: 288, Summer CFM: 128 12,651 4,176 2,671 6,847 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Sensible Gain Total: 28,496 Temperature Swing Multiplier: - _ X 1.00 System 1 Load Totals: 42,865 4,176 28,496 32,672 Check Figures Supply CFM: 1,296 (4.1 AC/hr) CFM Per Square ft.: 0.720 Square ft. of Room Area: 1,800 Square ft. Per Ton: 584 -System Loads -- ---- ___ Total Heating Required With Outside Air: 42,865 Btuh 42.865 MBH Total Sensible Gain: 28,496 Btuh 87 % Total Latent Gain: 4,176 Btuh 13 % Total Cooling Required With Outside Air: 32,672 Btuh 2.72 Tons (Based On Sensible + Latent) 3.08 Tons (Based On 77% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. 'a .lanuary OF; Pnnf; P-04 AM Rhvac-Residential&Light Commercial HVAC LoadsElite Software Develo ment,Inc. Ocean State Htg&A/C Barker Residence Neptune Beach,FL 32266-1798 Page 6 - - - - - System 2 Summary Loads Component Area Sen Lat Sen Total Description - Ouan Loss Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 195 5,655 0 8,230 8,230 9G French Door Double Clear Glass Wood Frame 72 1,503 0 1,627 1,627 12H Wall R-19+ 1/2" Gypsum Board(R-0.5) 783 1,879 0 1,060 1,060 16G Ceiling Under Vent. Attic- R-30 Insulation 1083 1,430 0 1,536 1,536 Subtotals for structure: 10,467 0 12,453 12,453 People: 4 920 1,200 2,120 Equipment: 0 400 400 . Lighting: 0 0 0 Ductwork: 880 0 1,556 1,556 Infiltration: Winter CFM: 162, Summer CFM: 72 7,141 2,358 1,507 3,865 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Sensible Gain Total: 17,116 Temperature Swing Multiplier: X 1.00 System 2 Load Totals: 18,488 3,278 17,116 20,394 Check Figures S upply CFM: 779 4.3 AC/hr CFM Per Square ft.: 6.7-1-9- Square .71gSquare ft. of Room Area: 1,083 Square ft. Per Ton: 585 -- -- - - System Loads -- Total Heating Required With Outside Air: 18,488 Btuh 18.488 MBH Notal Sensible Gain: 17,116 Btuh 84 % Total Latent Gain: 3,278 Btuh 16 % Total Cooling Required With Outside Air: 20,394 Btuh 1.70 Tons (Based On Sensible + Latent) 1.85 Tons (Based On 77% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. j j n,...:,, o,..i.... .h., Grirlav Iani iary OF, 9nog A.n4 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Ocean State Htg&A/C Barker Residence 1 Neptune Beach,FL 32266 1798 Page e -- - System 3 Summary Loads - - - - - Component Area Sen Lat Sen Total Description - -- - -- --Quan Loss - Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 160 4,640 0 8,459 8,459 9G French Door Double Clear Glass Wood Frame 48 1,002 0 1,779 1,779 12H Wall R-19+ 1/2" Gypsum Board(R-0.5) 1402 3,365 0 1,901 1,901 16G Ceiling Under Vent. Attic- R-30 Insulation 1870 2,470 0 2,654 2,654 201 Floor Over Open Crawl Carpet+ R-19 1036 1,989 0 696 696 Subtotals for structure: 13,466 0 15,489 15,489 People: 8 1,840 2,400 4,240 Equipment: 0 800 800 Lighting: 0 0 0 Ductwork: 5,374 0 4,304 4,304 Infiltration:Winter CFM: 305, Summer CFM: 135 13,398 4,423 2,829 7,252 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Sensible Gain Total: 25,822 Temperature Swing Multiplier: X 1.00 System 3 Load Totals: 32,238 6,263 25,822 32,085 Check Figures Supply CFM: 1,175 (3.5 AC/hr) CFM Per Square ft.: 0.578 Square ft. of Room Area: 2,032 Square ft. Per Ton: 727 System Loads --__ --_---- -Total Heating Required With Outside Air: 32,238 Btuh 32.238 MBH Total Sensible Gain: 25,822 Btuh 80 % Total Latent Gain: 6,263 Btuh 20 % 'Total Cooling Required With Outside Air: 32,085 Btuh 2.67 Tons (Based On Sensible + Latent) 2.79 Tons (Based On 77% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I i i I i Fririnv .lanimry nr, 200R_ 8.04 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Ocean State Htg&A/C Barker Residence Neptune Beach, FL 32266 1798 Page 8 System 4 Summary_Loads Component - _ _ _..--_-_ -- ------ Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 229 6,641 0 8,709 8,709 9G French Door Double Clear Glass Wood Frame 96 2,004 0 2,170 2,170 10D Door Wood Solid Core 24 442 0 250 250 12H Wall R-19+ 112" Gypsum Board(R-0.5) 971 2,330 0 1,318 1,318 16G Ceiling Under Vent. Attic- R-30 Insulation 1101 1,453 0 1,563 1,563 22A Slab on Grade No Edge Insulation 132 4,276 0 0 0 Subtotals for structure: 17,146 0 14,010 14,010 People: 4 920 1,200 2,120 Equipment: 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 1,219 0 1,795 1,795 Infiltration: Winter CFM: 165, Summer CFM: 73 7,257 2,396 1,533 3,929 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Sensible Gain Total 19,738 Temperature Swing Multiplier: X 1.00 System 4 Load Totals: 25,622 3,316 19,738 23,054 Check-Figures- Supply heckFiguresSupply CFM: 898 (4.9 AC/hr) CFM Per Square ft.. 0.816 Square ft. of Room Area. 1,101 Square ft. Per Ton: 515 System_Loads Total Heating Required With Outside Air: 25,622 Btuh 25.622 MBH Total Sensible Gain: 19,738 Btuh 86 % -Total Latent Gain: 3,316 Btuh 14 % Total Cooling Required With Outside Air: 23,054 Btuh 1.92 Tons (Based On Sensible + Latent) 2.14 Tons (Based On 77%Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I i I. n- r) \ ;o_RnrLear rh%/ Fridgv_.Ianuary 06_ 2006- 9:04 AM Rhvac-Residential&Light Commercial HVAC Loads Ocean State Htg&A/C Elite Software Development,Inc. - Barker Residence ' Neptune Beach, FL 32266-1798 Page 9 - - - - - - ystem I Room Load Summary - - Htg Htg Run Run Clg Clg Clg Zone Cig Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM ---Zone 1--- - - - - - 1 Dining 304 8,958 116 3-6 484 5,965 1,032 271 1.05 285 271 2 Pantry 150 1,163 15 1-4 257 493 149 22 1.00 22 22 3 Kitchen 208 4,880 63 3-6 591 6,123 466 279 1.25 348 279 4 Powder 64 2,615 34 1-6 540 2,221 155 101 1.05 106 101 5 Family Room 891 13,490 175 4-6 482 6,654 1,305 303 1.25 378 303 6 Entry 119 9,585 125 3-6 503 6,208 1,044 282 1.05 297 282 7 Pool Bath 64 2,174 28 1-4 434 832 25 38 1.00 38 38 System 1 total 1,800 42,865 557 28,496 4,176 1,296 1,475 1,296 System 1 Main Trunk Size: 20 in. Velocity: 594 ft./min Loss per 100 ft.: 0.045 in.wg Cooling System Summary - _— -- --- Tons Split Btuh Btuh Btuh – - --- - - Cooling Sensible/Latent Sensible Latent - Total Net Required. 2.72 87/o/ 13% 28,496 4,176- 672 Recommended: 3.08 77%/23% 28,496 8,512 37,008 I i I i I; l ('•\Plitc\RhvarIeAPrnicrtc\(l%nmar-Riiilrlarc\naan nAvic-Rarkar_rhv Friday. January 06. 2006. 8:04 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Ocean State Htg&A/C Barker Residence' - Neptune Beach,FL_32266-1798 ____ Page 10 System 2-Room. LoadSummary one Clg Air, Room — ---- Area --Sens Nom Duct_ Duct SenHtg Run Run s Lat Nom Clg Z Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM ---Zone 1--- 8 Master Bedroom 358 9,099 118 4-6 532 6,808 1,758 310 1.35 418 310 9 W.I.C. 260 1,309 17 1-4 559 925 106 42 1.16 49 42 10 W.C. 72 2,309 30 1-6 466 2,013 265 92 1.00 92 92 11 Master Bath 225 3,581 47 2-6 578 3,994 424 182 1.25 227 182 12 Office 168 2,190 28 2-6 489 3,376 725 154 1.25 192 154 System 2 total 1,083 18,488 240 17,116 3,278 779 978 779 System 2 Main Trunk Size: 16 in. Velocity: 558 ft./min Loss per 100 ft.: 0.053 in.wg Cooling System Summary - __ --- Cooling Sensible/L Split - Sensible Latent Btuh Btuh - Btuh ' Net Required: 1.70 84%/ 16% 17,116 3,278 20,394 Recommended: 1.85 77%/23% 17,116 5,113 22,229 II , I I is i 0 Cli+n\❑i— ^%AADr inn+c\n%Ainor-Ridlrlorc\non n navic_Rnrkor rhv Fririav .lanmgr\/f1R POOR R•04 Ann Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. ' Ocean State Htg&A/C Barker Residence Neptune Beach, FL-32266-1798 - -- _ -- - - - - Page 11 System 3 Room Load Summary - - --- ---- - _ - -g - g --- - g _ -9 -- - Ht Ht Run Run CIg CI CIg Zone CI Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM ' ---Zone 1--- - - - -- 13 Kilty 336 6,162 80 3-6 567 5,874 1,438 267 1.25 334 267 14 Hall 162 0 0 0-0 0 0 0 0 1.00 0 0 15 Laundry 162 1,114 14 1-5 626 1,877 128 85 1.00 85 85 16 Trevor 336 5,254 68 2-6 576 4,973 1,183 226 1.00 226 226 17 Colin 336 6,574 85 2-7 451 5,294 1,289 241 1.00 241 241 18 Rec Room 700 13,134 171 4-6 565 7,804 2,225 355 1.25 444 355 System 3 total 2,032 32,238 419 25,822 6,263 1,175 1,330 1,175 System 3 Main Trunk Size: 20 in. Velocity: 539 ft./min Loss per 100 ft.: 0.037 in.wg Cooling System Summary - Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.67 80%/20% 25,822 6,263 32,085 Recommended: 2.79 77%/23% 25,822 7,713 33,535 i �j Fririav- .laniiary 06. 2006. 8:04 AM - Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inca Ocean State Htg&A/C Barker Residence Neptune Beach, FL 32266-1798 Page-:-- - - --- - - - - - - e 12 System 4 Room Load Summary- Air Room - Area -- Seng Htg un Run l Nom —Duct Duct Seng Lag Zone - Nom - Cl Sys Y No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM - - -- -- - ---Zone 1--- — - - -- -- - - 19 Family 391 11,845 154 3-6 520 6,734 1,345 306 1.00 306 306 20 Kitchen 221 4,503 59 2-6 547 4,718 371 215 1.00 215 215 21 Bedroom 2 195 4,167 54 2-6 587 4,056 769 185 1.25 231 185 22 Bath 91 928 12 1-4 563 864 62 39 1.25 49 39 23 Bedroom 1 203 4,179 54 2-6 460 3,366 769 153 1.18 181 153 System 4 total 1,101 25,622 333 19,738 3,316 898 982 898 System 4 Main Trunk Size: 18 in. Velocity: 508 ft./min Loss per 100 ft.: 0.038 in.wg Cooling System Summar r�_ -- Cooling Sensible Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 1.92 86%/ 14% 19,738 3,316 23,054 Recommended: 2.14 77%/23% 19,738 5,896 25,634 I I i .+n\rlumor_RnRrlcrc\rlcan fhvic_Rarkar rhv Fririav .lanuary ns- tom. 19.04 AM „sr� e1,.1•t. CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD =� ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 JI,Il' INSPECTION EMAIL REQUEST: Building-deptna coab.us Application Number . . . . . 07-00001.618 Date 12/18/07 Property Address . . . . . . 620 BEACH AVE Application type description WELL PERMIT Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------ Application desc INSTALL WELL FOR IRRIGATION ----------------------------------------------------------------------------- Owner Contractor Barker ----- WILLIAMS WELL DRILLING INC 620 BEACH AVENUE P. O. BOX 330567 ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241-8489 Permit . . . . . -. - WELL-PERMIT--------------------------------------- Additional desc . Permit Fee . . . . 35. 00 Plan Check Fee _00 Issue Date Valuation . . 0 Expiration Date . . 6/15/08 . FeesummaryWCharged---- ___Paid--- -Credited `----Due--------- --- Permit Fee Total 35. 00 35. 00 . 00 ------ .00 Plan Check Total .00 00 00 00 Grand Total 35. 00 35. 00 . 00 00 PERMIT ISS'APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC B ACH PERMIT ` BUILDING / ZONING DEPARTMENT APPLICATION # 800 Seminole Road Atlantic Beach,Florida 32233 ' (904)247-5000 (904)247-5845 Fax www.coab.us APPLICATION TRACKING FORM REQUI R DEPT: Y Id PLANNING Property Address: _ �_ z Y BUILDING I' PUBLIC WORKS I � Applicant: I b V N, PUBLIC UTILITIES Y FIRE DEPT. Project: Ial Y Id PUBLIC SAFETY U) APPROVAL 00 REQUIRED AGENCY: RECEIVED BY: INITIAL: DATE: w Y N D.E.P HUFSTETLER C9= <Y N S.J.R.W.M. CARPER UJ _ Y N ARMY CORPS of ENG CARPER a Y N HOTELS&RESAURANTS HUFSTETLER APPLICATION STATUS CIRCLE ONE: 51TF BUILDING DA AP REVIEWE BY: I L: DATE: ® 1ST REV ® 12-3—z57 PLANNING ® ® El 11 BUILDING 2ND REV PUBLI WO S PUBLI U I IES FIRE EPT. PUBLIC SAFETY ® ® 3RD REV Return this fbim t®the Building Department once you have entered your comments into the AS400. Y u i1 yr CITY OF ATLANTIC BEACH WELL PERMIT APPLICATION Date Owner's Name: LeAk z Address: (< 5 Well Address (if different than above): 6jQ 3 0-Ad\ Well Location on Property(i.e. northeast corner,etc.) Well Installation Contractor:li/4&�k wtS Contractor License No.:-� l —Phone:E � FAX: �. �1 0-716-77 Contractor Address: PD� �/� S�7 �l�t�t`L �� C Check Use of Well: Domestic Irrigation V Other Estimated-Well Depth: Z.a Casing Depth Screen Interval fromrZd t4 Well Diameter: 3/ Casing Material �L _ Is ad&ess currently connected to the City water system? __7�".L — Is address currently connected to the City sewer system? V� Has a Well Permit been obtained from the City of Jacksonville?Permit# Does the well require a permit from the St. Johns River Water Management District? (Not required for wells under 2-inches diameter installed by resident or wells under 6- inches diameter if installed by licensed well contractor). Al'U If permit is required,note Permit Number and attach a copy. Aw NOTE: WHENA WELL IS INSTALLED ON YOUR PROPERTY, YOU MUST INSTALL A REDUCED PRESSURE ZONE TYPE BACKFLOW PRE VENTER ON THE CITY WATER SERVICE ON THE CUSTOMER'S SIDE OF THE METER THE BACKFLOW PREVENTER MUST BE TESTED BYA CERTIFIED TESTER AND A COPY OF THE RESULTS SENT TO THE PUBLIC UTILITIES DEPARTMENT. FILE "WOO* .,w,% COPY EVALUATION ENTITY MANUFACTURER xGary Pfuehter,P.E. Product Evaluation Report Clopay Building Products Company 5665 Green Oak Court for Florida DCA 8585 Duke Blvd. Fairfield,OH 45014 Mason,OH 45040 Evaluation Report# 4300W8-09 513.770.4800 Statement of Compliance: The Clopay Building Products Company sectional doors as described on the drawings listed below meet the design and test pressures shown.Based on the testing and rational analysis detailed below,this product is evaluated to be in compliance with the following provisions of the Florida Building Code: 11 Outside the HVHZ: Wind Loads(tested in compliance with FBC 1714.5.3.1,ref.ANSI/DASMA 108 or TAS 202) ®Inside the HVHZ:Wind Loads for HVHZ(tested in compliance with FBC 1714.5.3.1,ref TAS 202), 1625 Cyclic Tests for HVHZ(ref.TAS 203), 1626 Impact Tests for HVHZ(ref.TAS 201) Description of Product: Double-skin Insulated(exterior skin 27 ga.min.;interior skin 27 ga.min.) Single-Car(up to 9'0"wide)WINDCODe W8 Garage Door Design Pressures:+48/-60 Test.Pressures:+72/-90 Specific Models and Technical Documentation: Model Test Report Drawing No. Comments 4400W8,440iW8, HDGW8,HDGLW8, ATL- 101703-Rev06 Low head room track approved per HETI-03-1340. 4300W8,4310W8, 1112.02-96 4301 W8 ATL- 66W8,67W8,68W8 1112.02-96 101703-Rev06 Low head room track approved per HETI-03-1340. H400W8,H401 W8, ATL H300W8,H310W8, 1112.02-96 101703-Rev06 Low head room track approved per HETI-03-1340. H301 W8 Installation requirements:Installation must be in accordance with manufacturer's installation instructions. Limitations and conditions of use:Jambs,lintels,sills or other structural elements required to prepare openings are not covered. The design of the supporting structural elements shall be the responsibility of the professional of record for the building or structure and in accordance with current building codes for the loads listed on the drawing referenced above. Certification of Independence of Evaluation Entity:I hereby certify that(1)I have no financial interest in Clopay Building Products Company;(2)I am an independent licensed Professional Engineer in the State of Florida;and(3)I comply with the criteria of independence as stated in 9B-72.110 F.A.C. Signature: Gary Pfuehl �?' E. Florida P.E.No.49850 Date: C p'(ODUC T a o n0 0 ��J/� Q�[( Qa ll//J/{lLA V L�=1� FILE COPY �r►�.Al�r+ s ,W T1 :. BCIS Home ? Log In Hot Topics Submit Surcharge Stats&Facts Publications ; FBC Staff I BCIS Site Map 1 Links x Product Approval i USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL6073 Application Type New Code Version 2004 o Application Status Approved Comments SEEM Archived { « Product Manufacturer Pella Corporation Address/Phone/Email 102 Main St. Pella, IA 50219 (641) 621-1000 jahayden@pella.com Authorized Signature Joseph Hayden jahayden@pella.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Double Hung Compliance Method Certification Mark or Listing Certification Agency Window and Door Manufacturers Association Referenced Standard and Year (of Standard Year i BCIS Home M Publications mm�� FBC Staff ;' + , BCIS Site Map Product A roval Menu > P--duct or A PplIcn • Ap lSe-r-ch >4p-p itation ion Llst> TypeApplication �etarl Code version PL5710 ApplicationNew Status Comments 2004 77 Archived Approved t Product Man Addufacturer r ess/phone/Email Pella Corporation 102 Main St. Pella, jq 19 (641) 621-1 C)O0 Authorize .1aha d Authorized Signature y en@Pella.corn Joseph Hayden � Technical .laha Represe yden�peNa.conn Address/Phntative one/Email Add l ity Assurance Re cess/Pho presentative ne/Email Category Subcategory Exterior Doors Compliance Method Swinging Exterior poor Assemblies CertitrcationCertiRcatio Agency n Mark or Listing R .,,(of Window and poor Manufacturers anufactureCs ed Standard and year Association Ste__ndard Year FILE COPY D 66 SCIS Home Log In Hot Topics } Submit Surcharge i Stats&Facts ? Publications s FBC Staff = BCIS Site Map Links 'I i ,�, Product Approval i!1t USER: Public User • I, + Product Approval Menu > Product or ADDlication Search > Application List > Application Detail FL # FL4873 Application Type New Code Version 2004 Application Status Approved Comments Archived z:" Product Manufacturer Pella Corporation Address/Phone/Email 102 Main St. r , . Pella, IA 50219 (641) 621-1000 jahayden@pella.com Authorized Signature Joseph Hayden jahayden@pella.com Technical Representative MINIM= ,,, , i,, ,,, Address/Phone/Email Quality Assurance Representative i Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency Window and Door Manufacturers Association Referenced Standard and Year (of Standard FILE COPY" .YPOO r " M I A M PDADE MIAMI-DADE COUNTY,FLORIDA _ METRO-DARE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE(BCCO) 140 WEST FLAGLER STREET,SUITE 1603 PRODUCT CONTROL DIVISION MIAMI,FLORIDA 33130-1563 (305)375-2901 FAX(305)375-2908 NOTICE OF ACCEPTANCE (NOA) CertainTeed Corporation 1400 Union Meeting Road Blue Bell,PA 19422 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami-Dade County Product Control Division and accepted by the Board of Rules and Appeals(BORA)to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Division(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Landmark 30(and-AR)(and WideTrack QB),Landmark 40(and-AR)(and WideTrack QB)and Landmark 50(and-AR)(and WideTrack QB) LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 4. The submitted documentation was reviewed by Frank Zuloaga,RRC NOA No.:02-1219.03 a , Expiration Date:02/28/07 Approval Date:03/27/03 Page 1 of 4 FILE COPY 10/28/2004 00:04 PAZ 004 402 TUG WAM coo ' MMMUWW CM#M.MMM Tanta MDBRAO toe poomm a 'lud0 AO Meat FLAAW"81�1 ergs we MtAK FL0 MA nim-na (M)373-M) FAX M375.2= CW ALM[.$ 1"w cmk Ltd Yb11t+iAr121uw1InI ftway ` 1Rs(b vim W VxlnLi Cma 7iri.2iC�►ie tadg iaaaa rodiedMr��apd rs •� the wo+eR a,�iahl. 'AM daaa�iaa anba�ped boy beearari�i bF itti�eoi,DudeGOoatpp Castrol Ditisim apd aoorpNd ty dro9owd ofd @ad Appeeil(WW*)tolwwdis MWd Va6Cmq at 9&w srw wber0 d v Agby 1MAx*w*B' irMJ*bditm(AMIN IM M&dal amt be%Wm On din apbmim 4w shat below.?Y Ubmwu&Comw troeior:t ca" Dirbita(lb MWd Dab One"mdfor So AN Ps s o6w tMa MhW Drina CwaW)n own do eisbt IP base dds pp"ar mw del ts;ttod brow*ow*eoau—or Vwpm.if dds pia wk ar n torW f&10 p Jb - in - dwr aseeptai Mogua;dr wM hour da:expsute of a*naft wed do AM a w kood * mgb&soft,or ampad dr tso of t peodttat er ar■�tiv Mtiia dsdr f misdictim 1 A eoown■s tine tr erYolp H0 sooeplssoeti iiit is dMwtrdoed by DOds�ltiodret t'.asfeW otrgian drt dds pe+od�rat W mpni�i�t111Q>nsallNreq�e�rafiK>�r�b&bsiaads. 'lbir pcOdmet ie sppraaad ss dsser&sdbeteia.wad 1r,a bear ieeipad ro oeaooply wteh t6e>ii�ls Yeiooiq►ilrsriosne - Zoon ot'lire FWryds B char. LAUUM&go&ON dMA WW 8 Pam=W)Ad WN 20SWA60UMIG MW or ioMq ift6 dila Bpd hMoWifto-I I I ".i►Ilsorifia&Cenad►AI I&1 CO"A~,UWM 065"AW Uftdbarsib. - �►AI,ottirir2+tOA rMli bs oarroidpadaiirrsameral app�iarebwlwbaee 5bd ssd�baa baoa yrs ���„ ,y � , dMpsAbwa•roea[tMs pre4act ' IA7b01�1o[drirl�IQA�oomtt dor'1ir srq�rintlos dswari[tbpv l�ao boar snMi>iga or�roils mbOtbds„pre,aadRor sidre peeduotarp�w.>�ue ottlael�lDA as ma�odd► . iMdr rr oitds140A dM be a 06 Of POOL NOA.Fi�tre bQ eaaspiY AWi= fit:TM MA �- I by as ow&!► CMW,Fl 666 ad foDoWad by -a p-ndmiae anal►bo dbipif�d h►rd c air ice►arra.rp� .d �k aball be dome iaiaoOtaEq► �1'ifidOCl7ON.l A copy of aotbs I40A s1a�bf prvr#ded to dta wwr ba►dIc a(p dkpibetion ad ekutl be aMadsbb llbr be*""at**job dts st So 14040 offt Offm*L 11&4wdm ad pop l dpouab 4- 7ba*Aw ted dmmm+a0ou►w.e+ t by Pepdc 7Ma ,1tdIC 140A I%04 007df ,// - ��Y � �f� lwpe 1 ef0 2d Wi6£:60 D se ';00 'ON Xd l W08A City of Atlantic Beach - 800 Seminole Road -Atlantic Beach,Florida 32233 Phone: (904)247-5800 - Fax: (904)247-5805 - http://www.coab.us ORDER of the Community Development Board for the City of Atlantic Beach, Florida APPLICANT: Bryan and Leah Barker 1225 Selva Marina Circle Atlantic Beach, Florida 32233 FILE NUMBER: ZVAR-2006-01 DATE OF HEARING: April 18, 2006 ORDER GRANTING VARIANCE The above referenced Applicants requested a Variance to allow a nonconforming structure to be reconstructed in the existing footprint for property within the RS-2 Zoning District and located at 620 Beach Avenue. On, April 18, 2006, said request was considered at public hearing by the Community Development Board for the City of Atlantic Beach. Having considered the application and supporting documents, and comments by the Applicant, the Community Development Board, approved the request, finding this request to be consistent with Chapter 24-64 of the Land Development Regulations and consistent with the desired and traditional character of Beach Avenue. NOW THEREFORE, the Community Development Board hereby GRANTS this request for a Variance to allow a nonconforming structure to be reconstructed in the existing footprint for property within the RS-2 Zoning District and located at 620 Beach Avenue as depicted on the attached Site Plan. DATED THIS DAY OF_ j1tott,,7 , 2006. Sam Jacobson, Chairma Community Developme Board Attachment REVISIONS x ,, wI � � I , I I ' I I I I ' d �04 RY GAR PORT EXI�411NCs i w ONgtI I x u FRAME GA ACBE v w I ---------- a u I , O N ------- - -- ---------- - - r77 li 1 I w I U I i - ----- ---- ---------- - - i I ORY I RESIDENCk o. BEACH AE II I al I I I � i I � ET DATE IX+ OVERALL COMBINED SITE PLAN 04-O3-6W DRAWN BY: F16P .T N. 2 PROPERTY LINE E----- ---- ISTI I 20 RE R� - S I i , 1 1 I 1 , I i I , r1__J 1 ..1 1 w � 1 1 I I I , Z I E `tOR w I � h1 �R1' U EX U O 1 I 12 _ ' 0' RON FT SETS LINE ------ �' �I - ' [T—Fk(:PT-PROJ —TI-ON LINE .n PROPERTY LINE 6 th STR CITY OF ATLANTIC BEACH ' 800 SEMINOLE ROAD v ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Buildin-de, t-&-Coab.us Application Number . . . . . 06-00031960 Date 11/01/07 Property Address . . . . . . 620 BEACH AVE Tenant nbr, name . . . . . . SWIMMING POOL Application type description SWIMMING POOL/SPA Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 36000 Owner Contractor - - --- - ----- -- -- --- - ----- ---- - --- --- --- ---------- BARKER, BYRAN AND LEAH THE BATTS COMPANY 620 BEACH AVENUE 1602 NORTH THIRD STREET ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 246-2455 --- - ---- - ---- -------- --- ----- -- - --------------- ------ ------- - - -- ----- ------- Permit ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 75 . 00 Plan Check Fee . 00 Issue Date . . . . 10/31/07 Valuation . . . 0 Expiration Date . . 4/28/08 --- - --- - ------- --- ------ - ------------- - - -- - -------- --- ------------- --------- Fee summary Charged Paid Credited Due ----------------- -- -------- ------ ---- --- - - --- - - ---- - ----- Permit Fee Total 75 . 00 75 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 75 . 00 75 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH 7 0 . 800 SEMINOLE ROAD,ATLANTIC BEACH,FL 32233 • OFFICE:(904)247-5826•FAX NO.:(904)247-5845 BUILDING-DEPT@COAB.US }x= ELECTRICAL PERMIT APPLICATION DUVAL COUNTY � ,s .�:y�ar.��„&<;„ ;� e � '�,'., ;r: r bt s Atlantic Beach, FL 32233 YES PERMIT#:t)(0-3 l too I� :3 t I � ,s '`Z''�1 `� a x e -sem i 4.NAME: n 5.ADDRESS IF DIFFERENT FROM JOB ADDRESS: 6.PHONE: 8.ADDRESS.: 7.N !&COMP NY: •--• k S0 aA 9.S TE OF FLORIDA LICENSE NO: 10.C L PHONE: V 11.FAX NO.: 12.E AIL DD ESS: • 13.OFFICE PHONE: 14. 164- R147- alai 15.Application is hereby made too lain a permit to do the work and installations as indicated. I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6) months,or if construction or work is suspended or abandoned for a period of six(6)m s at any time after work' commenced. CONTRACTORS SIGNATURE: �t;.`. " , ...➢ .ae.1.t,.fir;to t� ', .�a;�,� e wa�a�.�,o'� �; ,44 , :1, i. .zea,, ,�� ,4� .:" 4 J"�.'�,.h'`?�<a�.,�bk 1 .�°4a�.�'�. ❑MULTI FAMILY-#OF UNITS: RESIDENTIAL SINGLE FAMILY ❑TEMP SERVICE ❑COMMERCIAL ❑ADDITION ❑TRAILOR ❑ALTERATION ❑SIGN Iff OLD ANEW ❑'05 NATIONAL ELECTRICAL CODE ❑REPAIR ❑POOL/SPA ❑REWIRE ❑OTHER: 'v 20.TYPE OF SERVICE: ❑OVERHEAD ❑UNDERGROUND ❑ UNDERGROUND UP POLE 21.NEW SERVICE: CONDUCTORS PER PHASE: ❑ POWER IS ON ❑ POWER IS OFF 22.SIZE OF CONDUCTOR: AMPACITY: ❑COPPER ❑ALUMINUM 23.SWITCH OR BREAKER SIZE: AMPS: PH: W: VOLT: RACEWAY SIZE: 24.EXISTING SERVICE SIZE: AMPS: PH: W: VOLT: RACEWAY SIZE: 25.FEEDERS: #OF AMPS: #OF AMPS: #OF AMPS: 26.LIGHTING FIXTURES: INCANDESCENT: FLUORESCENT&M.V.: 27.FIXED APPLIANCES: 0-30 AMPS: 31-100 AMPS: OVER 100 AMPS: 28.FIRE ALARM: ❑YES ❑ NO 29-31 DO NOT APPLY TO NEW SINGLE FAMILY,MULTI-FAMILY AND ROOM ADDITIONS 29.SMOKE DETECTORS: NUMBER: 30.RECEPTACLES: 0-30 AMPS: 31-100 AMPS: OVER 100 AMPS: 31.SWITCHES: 0-30 AMPS: 31-100 AMPS: OVER 100 AMPS: ".i' c,g ,ia,,C. ,as x�s�• '�°R'�. �� �,.�arm ;.a ° .3.5 q r?k,` raa rnr �,., .;ar ar,.�,.. a „�, rs ;�,, #OF UNITS: COMP.MOTOR HP RATING: AMPS: HEAT KW: #OF UNITS: COMP. MOTOR HP RATING: AMPS: HEAT KW: 11 221 NUMBER: VOLTAGE: HP: KVA: NUMBER: VOLTAGE: HP: KVA: ��.r���.�'�^ �.,, •,� „R.r ��<t �� ..�„a �_;� .x? (�„�,,,, L "41&�a���, ws 4¢ � w�<.a �A;�wc .t. �'��i� �� w ,��.-a� UNDER 60OV: NUMBER: KVA: OVER 60OV: NUMBER: KVA: r4;i#< '”£ ,€� F t `rr,.<„ °'' • " µ . Ire '; I Nr r DESCRIBE IN DETAIL: COAB FORM BLDG02:REVISED:9/26/2007 HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 2 May 25, 2006 Re: PERMIT for Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE PUBLIC WORKS DEPARTMENT OF THE CITY OF ATLANTIC BEACH. Item No. 1 Sheet A-1 is revised and reissued to; Show Erosion and sediment control on Site Plan and to provide detail of sediment fence. Show concrete pavement at driveways from the property line to the edge of existing pavement in lieu of brick pavers on sand bed. Brick pavers at walks removed from city right-of-way. c�� REVISIONS Ai M-0-ft ER06tCN CP�tR0.ADDED ti#-16•Q* w �e .0 M K 0g K Dow r•wLtu '• LA104CAPI AMA I t CONC!!TE P.V@1lNT I ( 14tlOL PAv[RB TO MATCH CITY C} 1 , t OARMAI ATL.YVIIC*EACH ' i j I ( IM:611R OIIN WT LR g6TT 1 ELOPE DNh` IL _.....�', I t to to"OF T`KX*TIG 1� � Q v HAr W >tz: -iREA AFil:A tiS U W _-.._._.._________..._ .Eplidl Ai hr \ W.DEI'M 71 �/ 1k4l D RLDOR i 7` AAJ'� \ ! CY.FT. fit C4 w t` maoc .OAHU FAMM Dow ,� W 1 �p.'o K�,14 FJ•� tr7 .. � � .h� � t • � #�Tt}iCK ' - N� N' w arc• + \y�x x \. ,,'• C.tpEATh NT AREA.`\ �.�\\� Faw t/e•utox \\ \ )004,R '� `\\�\' `. •\`\�\,.,MPX.DEPTH.3\\�\\'.\ .\\� �\\`\\\ K ' � gig o`•' 0 C7 y CLOTW mua"I,Pol YMTER Ort AFPWAP 1 r NGA L/Ott WOOD*TAKE#"MAX.X0'-0'OL. 1 ppp .. r •ACIMLL PO4E AFTER FLACM KNGI y 6glelaeo Lors LAN TREATMLNT AREA REM(W-0.ua COPT. TtEdThyMT Apg.4 pWNDED.460 CUfT. �'• ('.CLIME CALCULATED AT WnC M CF kOFE1 \v'\,r>�h.Y 1111 )1 t W6P t']SR0�1dN VA2 DATA, R)OOT#o GACA%MAUA,t4 W!, nSEDIMENT GQNTRO FF�irc i i I u� 5 � x j•' yx x Xy' Y x y y TO MATW WY OF ATLd•ITICKT#SlArAM - NIUrlRTY L'N! ENIGIM 1 I do 4-0 m 1 y F.rf KIM LAN06oft Ow O s I IM/R0. '\`��`n�\�• � r_:0.,?�w_`_� _... .._..__.-___ I �3ow7d4C... �srr - 1 \\\\\\\':\\ 1 k I � I i ( L►b1eAH A14 �' I .... OMS i I I A I 'N)R• 1 \.\ \\ !. 1 I. 16x Y,y 44, \\\\\' �yh I 1 j I ",\ eyw ..• x h ii ip ,a 4, I I { ok ee d LIIW ] O . - ..,,......n. C17RD OF bp. Y 0 14 ` \ \ M i fxj`• '\\\\\' I DO" - I I I a \ ADr1MAENTisA P1141 ED FLOOR 1 I 1 1 rM1AX.Dl1PTN { yy CAMGTY.136 IAX t• \`\• .,•' _ h—_ ' T.__._...k, II I �__. w117ckP w.W2\\ \ �..\ �� •Wa x -•_� _.--�:.i__.�_-..��__ .. a .L \ \` � 'N\' \ \ \ \ \DOrTCMAT ISI\\\ \ \.\ C. AC" \\ \o 105.97`IRON01, TO w \ \\•\ \\ \}1 \ \P \ Y xx�y FOUND 1 ~FIPC INO b) �� wlg7RrrLw ��.���.. t' \ .�\\• t \ > r4+�"�'C'�ta {.ate.` �.... M1 14 x J h Y 6 lb STREET QY �Y .aN x x NNOLE LOT: TREATMENT AREA REQUIRED.222 CUFT. i OVERALL 61 TREATMENT AREA PROVIDED.215 CUFL fGllE:Ly,r-p• 1VDLft4 CALQ"rED AT EDTTCM O OLCM 1 M&=&MACE DATA, SIT E ANSA:MPfy09 fF. EX161M gtADEf EXIpT►rG EVEIIIDUf 61EFAGE AACd WY OF. City of Atlantic Beach ' Building Department � 3Sr, Certificate of Completion This Certificate issued pursuant to the requirements of Section 110.2 of the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: Date: March 26, 2008 Contractor: Elite Homes Address: 620 Beach Ave., Atlantic Beach, F1 32233 Construction Type: Residential Occupancy Class: Group R-2 Permit Number: 06-31959 �&, WALT BROWN BUILDING OFFICIAL Building, Planning & Zoning CITY OF ATLANTIC BEACH Inspection Department CERTIFICATE OF OCCUPANCY WORKSHEET Date Requested: Contractor Name: Ah/n Permit #: ` 196-1 '0 a8o 3 Property Address: Legal Description: Improvements to the above-described property have been completed in accordance with the term of the permit and are certified to be ready for occupancy as: Single-Family Residence F-1 Commercial F-� Other: Lowest Floor Elevation: Required As Built FFE The following must be completed before issuing Certificate of Occupancy: Department Date Notified Date Approved Approved By Fire Z)e t. Public Works — Public Utilities AX Building Planning Final Survey with FFE YYes Yes No All Re-Inspect Fees Paid No Termite Treatment No t .E VA R D 60' RIGHT OF WAY PAVED o' IELD) o m 0 -t 22 Ld� CD 0 O W Z a ❑ ❑ N �u D N rr,N = O N r ---i ' 0 :u ul o c r m w 0.3' < 0 D N m o 000 a D o X OONZ Dm = Z {m ? / C Z � 0 Z � c � 0 r m Opo T> 0 Z D � � I r' D 0 q D a I z 0 Or O r env rn� 0 5 A 10.8 w C� cn Z k m J -0.5' O O = mz 22.0'\ n 'U > n V! 4.6' W G7 r �m �I 0) O D D rn< M \ \ Tf 1 • 1 I n n -� co c p�m 0 X 0 nI X ;u O Nz � -r A z � �I m l 16.o' 12,8' Wr .6' r /— 13.6' W I m -10 • 0° nr co O D 00 o� z�6 v <z 1 O O c/)D 0.6' C) Z Deo m 4\ �•. N IE D) i// SCALE: 1" = 20' [� NUEIE 40' RIGHT OF WAY PAVED i _E VA R D 60' RIGHT OF WAY PAVED #o' IELD) o m W0(C-) Wzz ❑ NJ ❑ ❑ �°� N m N 0 = O N m —I C) O �Q (A o C m A' < O w 0.3m <Z D C Nm D Z m r r I a: 0 � 0 Z C) A OW mom m r m 000 0 Z r' D 0 � D ED Z OS >> rn.._► C o r� 10.8' w R �' Z mZ W 6f 5 �� O 0 n No D V J 4.6' cyl rnm V! pA (I �� C o m I co m � o m D C _ + m _ p m o C7 n m C n X— O �> u) m o m 0 Z T o f o Z 1 ommk�0 C) A c- 16.0, 0 16.0' 12.8' W CD 13.6' „ Ln :IJm 7 oo m 0 () r- 0 O D 0o z �� z O O �� 0.6' nZz N N aM DSO r'1\ ?E D) SCALE: 1" = 20' NUE40' RIGHT OF WAY PAVED -n O o C: --4 _ m E5 Z F mm0 -,q r mE5. . . .. OCEAN BOU 70C mLoD DOOD OTmwazz -+ m 100 � p Nzo r� yp `' 00 - Dmz0�0�n (n 99.9E n r -i a7 -( cDg DpZD00 < >2T �� X z C/1 (n z D r ;� < x7Z �I � C N m CO� C�UD F OD -< b0 n � � � O x m �� �0z� z - � M I Z, OAC aym Z 1 R° �� m� 0 pyoc`- �0 t mom. zr m rn �C � DmZ zz0 ZUl D � m ➢ Vz i0rr, z-4 Deo O ❑ ❑ Dm x mCmpa7;a ,-� _ � r0) 5 � �7 � � � D� �mn >Oz � amD > y Z m -+> z;oU � COmz 'um - � Azm w mD m = --, 2D = < r m r ❑- p �z C7 � � p CO D000 D ❑ 00 Z O Y � 0� N ozzm � cD � pm p cnz z z to U, m S? om� � � o � m � zoo c- c: O � DO D O 0 -nn ❑ CrmD = r Tl m 0 =r / � c- �� n mZ = O rn c/) N o D m = Cc3Om 0 t�v -ziN _' o r— BMW , o �� o X o to rSm mD N < � �O m mO�Z (-n 0m "Q ZZ � oK) Om _O z � N vv i - 0 m C 0 D o o m CO D 0 _ O = r O G = D r� O O z U) - _I m p t n . O _I D 0 � V73' � 15 9' D � r m M j Z <� b= O LqC-) 00 0 00 D -0 (rel _ 14.7' D O 0 /f�o\ 19,8' c'zz / 2 DC D = Dv � 7.3' f —I mz .D CD m *1 ° o w -� rij ZO" N � m V T� Z mm m 100.6 -n x m r 99.31' w L,) 0 N N BEACH AVE -n 0 0 E: --4 z m D m ��'� � rvrm-- _� z = mE5cn �WN� Q OCEAN BOU x m� D Doo m i`I 00CMD Dzz m 100. p za rr- vQ. , QO � b �zc) x0� 99.96 Lc,:gg D ZD0O �<1DSmTCF CO ADO c) � x� � O mg� �0zm F�,F m I yOV)C ODm z R' �� m �00 :CI 00 W- Z r r r� CX> ;D z 0zmm � mD X = 2:r- iri i�> to � � � U) 0 C� D Z ° rri OD O � bD D z m -r� i00z� N u C`7 M C mZ � _ -aSD S� < W r M m r N �m� rD- � Dm D rt/)O *iDrZ1� O r m o p O r*t 0 C m> O �Z nr C O < cZr • -' Oco op O , c� m � z -i =oo X 0O > Z m G D z DD T ❑ m C m II Z p "T'1 � � r � -1m (D Zr -�7 ozzm O < O cnMR? 0 m CJD -0 � m � ZOO V/ ` 0CC7 > ;Z7Z0 O � �n ❑ z �1 < r. --r m r :< -+ CpmD 2r- `� m mora , n D0 � fel _W r L �� n Z = O rn V ! o Z ,� _ o PmN .r O m d (O �N O ` ' O r N < - -� cn Z X u, Z Z oDCN m � m O O Q � > O �2 S Ul�r r� v -� 5 zvm z o �cn � o N 1 Z M (� T'cn ='O o N g � m ai C O D m 00 D 0 T1 'TIO co --I Drnom+ r r :U = < O o Z O > v z U, r D 17 ;Q 15.9' n < 7.3 cq N X > Zl m - r < Ln `r+� y 8.o' D S O 00 0O O R' 0-� r z Q \�/ A z 0 W K .77 Q m �7 > Q � c? J J 14.7' J D O w 7cQ f0- in \ m u+ 2 Z77 Un�O O / �0 19.8' � zz _ N > m > -0 7.3' m - co 6 W Z.. m m D QJ m O (A � Z L mz Z m m o o '� 100.O 99.31' W �*1rn W N N BEACH AVE 0 r i J,f Ffs�` � CITY OF ATLANTIC BEACH 5j J 800 SEN[INOLE ROAD J ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 =% 1 INSPECTION EMAIL REQUEST: Building-ddept&oab.us Application Number . . . . . 08-00000087 Date 1/25/08 Property Address . . . . . . 620 BEACH AVE Application type description FENCE PERMIT Property Zoning . . . . . . . RESIDENTIAL GEN 2 FAMILY Application valuation . . . . 15000 ---------------------------------------------------------------------------- Application desc INSTALL 6 ' WOODEN/BRICK & ALUM. FNCE ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ Barker ELITE HOMES INC. 620 BEACH AVENUE Q/A:LAMBERTSON, CHRISTOPHER ATLANTIC BEACH FL 32233 77 19TH STREET ATLANTIC BEACH FL 32233 (904) 241-5251 ---------------------------------------------------------------------------- Permit . . . . . . FENCE PERMIT Additional desc . . Permit Fee . . . . 35 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/23/08 ---------------------------------------------------------------------------- Special Notes and Comments *ALL FENCES OR ENCLOSURES OF LAND SHALL BE SUBSTANTIALLY CONSTRUCTED. *SCHEDULE FINAL INSPECTION ONCE FENCE HAS BEEN COMPLETED. PERMIT AND APPROVED SURVEY MUST BE AVAILABLE FOR FINAL INSPECTION. *EMAIL INSPECTION REQUESTS TO BUILDING-DEPT@COAB.US Subject to: 1 .Approval shall be required by the Public Safety Department confirming that the fence, as proposed, shall provide no obstruction to clear vehicular sight distance at adjoining intersections . 2 .The fence shall be designed, constructed with insets and landscaped as substantively represented within the attached drawing and as verbally represented during the public hearing. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------- ---------- ---------- ---------- ---------- Permit Fee Total 35 . 00 35 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 35 . 00 35 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. o OCEAN C30UVA � n v v s T o 4„ VARIANCE REQUIRED rn f m N � N � D Cn�Z � m a 3 _ 2 Fq C O X D � V S X I � ..p 0i ;;-6� � p rcc I I � 1 1 co m cR D =x_ ( 2N ON 0 c rn � 1 1 1 FILE COPY P3 A C H AVNU � =�oaiv�s. _^ .` .-.�`__ yam' �v. • All • MISS Via: �•, , ,• r IS gi Ell a r'' +ri, • �r I A" a] , - Mft n 0 3 c9 U d c� tT $fi N F c9 N N 8 J O N Nco rri CO LO �— r� OXO � X *A O< \' Orri 0 Co co N -1 Z zm r<<100 O�-I4 ZO O' O z \ 3 m0�am ;o �n70C �0� my N O .. m zO m n Fri zC) a-'z-n rrl p — - (T1 O®mc CD ;UK�KV)Z O)OC> Fri En p Z7 DOO -� � G') ;u . �. o fel m a oo rri C) n \o D a m O NN Z Ln mnx m cn ;o(n v vino D zx m=i cz� m 1X8 BOARD FENCE (2° GAP) compacted 1X6 BOARD earth compacted earth d o da.P. .P •a o ' P' 4X4 POST 2X4 BOARD 4X4 POST (PLAN VIEW) 1X6 BOARD F 2X4 BOARD 4X4 POST 4X4 POST 72° 72.1 i i 2X4 BOARD i a• a• a a a a a o a a a a 2411 compacted- earth a a 2411 a o a a a a a a a (SIDE VIEW) (ELEVATION VIEW) DUVAL FENCE, INC. 2 PHILLIPS Jacksonville, FL 3225 6D VA FENCE/ INC* (904) 260-4747; FAX: 260-4256 board on board DRAWN BY: JMO 07/06/94 SCALE: NONE PAGE: (6' HIGH) REVISED: JMO 11/20/07 FILE: board onj 1 of 1 43Abd �,dM 30 1HON ,OV 3 n N W 313).«'66 ,00*00[ iv LJc'p \ �S o n o zz p o(Do a� H ry L` z o6 Q ON - -I U o0 Cl- w o0 LLJ � Lo co O Cn it - Lizo w C7 � wY�z ZpJpzv)O O O orf0 cr � `. LL Uo Q U Lj a W = LL C♦OO N w 1 O Zo aj u Q CY) .f VI � w C9 S.b Y C), Ln �t ` u7 .w U Q g.S L'll ri v Q Q Z = � -i o .� Y ,r- O z m LLJQ � oQ �o v �n o ^^ � zo � . 0— U 0 m LL- 0 Z O >- r� U z ry O Q Un U Q 'CO N - 00 O > L wZ) Uf) ry, r r- w OF- O \w n_ opo a^ D �� 0 z °� 0 a3Abd 1,VM A0 1H01 Ine HOV30 N N 0 ^1 r'► lhD If � � M Mt� ..t ,OZ.lOS O� w O M 100,01C.LOS m LL- w Z z w I W Y N O f ai O �w m Q w w Z +— �� a m a Z w Qao w CL Q w w AZO- I= mo m iv.L'9 ao S 6t a O X Z O �J U = o Z O O Q cd V n L bl ua o —J Li- LLJQ. Q eo ry (0� O w O-U11 0N N Q �Z ~O dS. `V � �` z m Q �C) Z p U r oma < � CrfL r O V)j O d'8 Q LL) p Lel - r ��F w 04 J Zit wa � � � < D lzw0 bll wm �' ` OOej t= .. co » .J O^ �+ of LL-- Oj o Z p ao O p J XLl LO v W w (J) p Jp o H m 0 11. Z£ CL 00 cra < '� m O v/� v^, w O yy J N L o Z^ Q 5 O Z �� Z o Q1 Wr J a O w0c.� � � -11 Oo V F-- Zw a4 F— a Orn w LL. A-OZ J OZ ~ Q o� rr^^ Q Q D w V 0f- L.J LL T- C) OV)o > z o rn - a arwo � Q Z Q O zza w= CL � F d m X QOL � z 0 r O o Z Ld 0 Z o p J O 0 CL -1 a o p r- Q w w O w Q - J w� tf! ~O \i` o >: 0-1 n w w w m � Q > � Qw J �O" ri � x 2 Zw Q a C N yw O~ Qr p z �` a 90� N NFy^ �z z a V Q OLO OH = Q �m Qptwp� O j� QwjU wmZ h oa oox�- Z Nw UwQ D U— w p4 U �Z ?lwN�� w J Q m r Lj(r i ��� mCO --Ow of O � (� OQW O o X06, aU)(D�O w N � Do �- Fra m z cn d QzoQ � Q = m 3 «DDS 00.00 N Ln X UJ o o M„OC,20.00N W i m-z-'z Q ls- z O h Q >o N U LLL Q O o Z w a Iii E- -1 -1 o u- l- w (� (� �] w J II lo � I V�_..J�O 0 Win, r�� r z dt� NO z=9 U � ti Z CITY ®F ATLAN'T'IC BEACH PERMIT B MI) G / ZONING DEP. TM[ENT APPLICATION # 000 Seminole Road QQ P' „> Atlantic Beach,Florida 32233 ,A, � c i (904)247-504)0 "s (904)247-5545 Fax www.coab.us APPLICATION TRACKING FORM RF^IRED DEPT: N PLANNING Property Address, �D� � Ly� z BUILDING _ PUBLIC WORKS Applicant: l,/l ��� �Z� CJ 0 PUBLIC UTILITIES Y FIRE DEPT. Project, briClell Y N PUBLIC SAFETY Lu APPROVAL v 0 1 REQUIRED AGENCY: RECEIVED BY: INITIAL: DATE: Z 0, Y N D.E.P HUFSTETLER Q 0 N S.J.R.W.M. CARPER 0Lu y Y N ARMY CORPS of ENG CAPPER Y N HOTELS&RESAURANTS HUFSTETLER APPLICATION STATUS CIRCLE ONE: SITE BUILDIN DA AP 5eVIEWED BY: INITI ATF: ® 1 ST REVFo �� �^ 6 fi �a.'�,� f.'P'1 `j''"7tG,vri tplPG .. rl�r-f'f� (Jq t`)i?(C` /-Io (,A) .TM.tJTQ-1' PLANNING __ ® ® 2ND REV BUILDIN T_O�T__ PUBLIC WORKS PUBLIC UTILITIES FIRE DEPT. PUBLIC SAFETY ® ® 3RD REV IPuxfimnm^mn+%ia fhrmmn fn fho 16$ani][Aina 11169Enortn'd ent Pllnee vnu have entered vour comments into the AS400. CITY OF ATLANTIC BEACH 0,7- 800 SEMINOLE ROAD,ATLANTIC BEACH,FL 32233 OFFICE:(904)247-5826•FAX NO.:(904)247-5845 BUILDING-DEPT(MCOAB.US BUILDING PERMIT APPLICATION DUvAL COUNTY 2.VALUATGION OF W K: 1, 3.SO.FT..UNDER ROOF Ale-VV-9- Atlantic Beach, FL 32233 151 n0®• A)JA a, 5.CLASS OF WORK: 6.USE QF STRUCTURE: L [3 NEW BUILDING _0DEMOLITION ESIDENTIAL LOT}BLOCK Ib sUB DIVISION � ❑ADDITION 13CONVERTING USE 13COMMERCIAL 7.DESCRIPT04 13 ALTERATION ❑ACCESSORY BLDG. 8.FIRE SPRINKLER: �! �/ n f ❑REPAIR ❑¢'O L/SPA 13 YES ❑N/A 3C ( 1�/ NJ� ❑MOVE THER ❑NO CONTRACTOR: ARCHITECT/ENGINEER: V OWNER:9.NAME: 15.COMPANY NAME: 23.COMPANY NAME: �jt�na earn Macke 2 4e- �T_NL 1 16 NAME: 24.LICENSEE NAME: Glnl�is �buashvr� 10.ADDRESS: 17.STATE OF FLORIDA LICENSE NO.: 25.STATE OF FLORIDA LICENSE NO.: la-A5 5e,VA #W Nck Cta4f- C- VA ADDRESS: 26.ADDRESS: MUM(, a63$ Ave4,u-0- A" 33 11.OFFICE PHONE: 12.FAX NO.: 19.OFFICE PHONE: 20.FAX NO.: 27.OFFICE PHONE: 28.FAX NO.: 13.CE PHONE 21.CELL PHONE: 29.CELL PHONE: b(ad-- 3 �l- Z$o 3 14.EMAIL ADDRESS: 22.,E,M1-AIL ADDRESS: 4J , 30.EMAIL ADDRESS: r1n�l•,esA 'I. FEE SIMPLE Ting HOLDER: BONDING COMPANY. MORTGAGE LENDER: (II`OTHER THAN OWNER) 31.NAME: 33.NAME_- 35.NAME: 32.ADDRESS: SS: 36.ADDRESS: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to most the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within sic(6)months, or if construction or work is suspended or abandoned for a period of six(6) months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Wells,Furnaces,Boilers,Heaters,Tanks, Air Conditioners,etc. OWNER'S AFFIDAVIT-I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. I will not occupy or use the referenced building or any part therof, until all inspections are finaled and prior to obtaining a certificate of occupancy or completion issued by the building official,as required by law. 222 WARNING TO OWNER: 222 YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER/OR AN ATTORNEY BEFORE RECORDING YOUR IWCE OF COMMENCEMENT. Q Signed: Date: fid 0$ Signed: Date: 17-n o Before me this day of-T#,A 0 A/ 2000in the county of Before me this day of 2007 in the county of Duval,State of Florida,has personalty appeared Duval,State of Florida,has personally appeared l_7 P,N/AA) 15A-'-) <II/' herin by himself/herself and affirms that all statements and declarations are herin by himself/herself and affirms that all statements and declarations are true and accurate. true and accurate. LeRlp TTI✓JAL Notary Public at Large,Sta County of Notary Public at Large,State Of County of Re.-ally Known Personally Known U Produced Identficati - ❑Produced Identificati Notary Signature: Notary Signature: JEFF"TT AV 0 Notary u Ic :DD674778 lo da + My FISSION#DD 734501 Albert Moreno BamW TEXPIRES: hruSN�otarry Pyr 14 2011 j COAG FORM BLDG01:REVISED:1/1612008 My Commissio E 05/151 CITY OF ATLANTIC BEACH SS 800 SE HNOLE ROAD ATLANTIC BEACH,FL 32233 v INSPECTION PHONE LINE 247-5826 Application Number . . . . . 06-00031959 Date 10/02/06 Property Address . . . . . . 620 BEACH AVE Tenant nbr, name . . . . . . SFR AND GUEST HOUSE Application type description SINGLE FAMILY RESIDENCE Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 800000 Owner Contractor ------------------------ ------------------------ BARKER, BRYAN AND LEAH ELITE HOMES INC. 620 BEACH AVENUE 77 19TH STREET ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 2330 . 00 Plan Check Fee 1165. 00 Issue Date . . . . Valuation . . . . 800000 Expiration Date . . 3/31/07 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . CITY RADON SURCHARGE 1 .50 ST CONSTRUCTION SURCHARGE 40 .26 AB CONSTRUCTION SURCHARGE 4 .47 STATE RADON SURCHARGE 28 . 57 WATER IMPACT FEE 120 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 2330 . 00 2330 . 00 . 00 . 00 .Plan Check Total 1165 . 00 1165 . 00 . 00 . 00 Other Fee Total 194 . 80 194 . 80 . 00 . 00 Grand Total 3689 . 80 3689 . 80 . 00 . 00 PERMff IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. IS CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Building-de�t(acoab.us Application Number . . . . . 07-00001564 Date 11/15/07 Property Address . . . . . . 620 BEACH AVE Application type description TREE PERMIT Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc TREE REMOVAL ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ Barker OWNER 620 BEACH AVENUE ATLANTIC BEACH FL 32233 ---------------------------------------------------------------------------- Permit . . . . . . TREE PERMIT Additional desc . . Permit Fee . . . . . 00 Plan Check Fee . 00 Issue Date . . . . 11/15/07 Valuation . . . . 0 Expiration Date . . 5/14/08 ---------------------------------------------------------------------------- Special Notes and Comments APPROVED TO REMOVE 1-611NAS 1-11" CHERRY LAUREL FROM REAR EXTERIOR ZONE,NO MITIGATION REQUIRED ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total . 00 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total . 00 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 06-00034585 Date 1/12/07 Property Address . . . . . . 620 BEACH AVE Application type description MECHANICAL ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc GAS TANKS/PIPING ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ FLORIDA PROPANE PARTNERS DBA:GRIFFIS GAS & MACK GAS 115 B SOLANO RD PONTE VEDRA BCH FL 32082 (904) 543-4343 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 55 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/11/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 55 . 00 55 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 55 . 00 55 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH MECHANICAL PERMIT APPLICATION J P�Jf31�(' Date: 1 • 4 7 Property Address: � -e_ Owner: k) Telephone#: Contractor: �`L �jr, �5 Telephone#: Contractor Address: 1641 d.. /ro t-n t Fax#: Contractor Signature: In consideration of permit given for doing the work as described in the above statement,we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinances and standards of good practice listed therein. Type of Heating Fuel: If other construction is being done on this building or site,list the building permit number: ❑ Electric Gas: )(LP _Natural ,Central Utility ❑ Oil ❑ Other—Specify MECHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK ❑ Heat `Space _Recessed _Central _Floor Ll Residential ❑ Air Conditioning: Room Room _Central ❑ Duct System: Material Thickness ❑ Commercial Maximum capacity cfin El Refrigeration ❑ New Building ❑ Cooling Tower: Capacity gpm ❑ Fire Sprinklers:Number of Heads ❑ Existing Building ❑ Elevator: _— Manlift Escalator (Number) L3 Replacement of Existing System L] Gasoline Pumps (Number) Tanks (Number) ❑ New Installation l' LPG Containers (Number) (No system previously installed) ❑ Unfired Pressure Vessel ❑ Extension or Add-on to Existing System ❑ Boilers K, Gas Piping ❑ Other-Specify ❑ Other—Specify LIST ALL EQUIPMENT AIR CONDITIONING,REFRIGERATION EQUIPMENT&CONDENSOR'S Approving Number Units Description Model# Manufacturer Ton's Agency BEATING—FURNACES,BOILERS,FIREPLACES&AIR HANDLER'S Approving Number Units Description Model# Manufacturer BTU's Agency TANKS Nominal Capacity Type Liquid Serial Approving How Many &Dimensions Contained Manufacturer No. Agency F , 800 Seminole Road v Atlantic Beach,Florida 32233=5445 Phone: (904)247-5800• Fax: (904)247-5845• http://www.ei.atlantic-beach.fl.us Revised 1/04 CITY OF ATLANTIC BEACH J> ;si -� DEMOLITION PERMIT APPLICATION Date: Job Address: �Or� �QCACh ftff, A4(&yrNC. &a(-C. , F� 3)a33 Owner of Property: ' 6a d2v— Address: `J (' 1 Telephone: (0(p0)-1,519 Legal Description: Block INumber: (P Lot Number: 3 Zoning District: Contractor: ��"��� State License Number: C�Pbc,b 5 C rr,, d Contractor's Address: " to I M Aue 5 • Telephone: Ow-off L4 (- 0?5( Fax: qCq`0LI_+I,—(0 I gy Describe proposed use and work to be done: �C��(i .. � 1(J►'�'Ct n Present use of land or building(s): Is approval of Homeowner's Association or other private entity required? If yes,please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material or the removal of any trees? ❑NO. Applicant certifies that no change in site grade or fill material will be used on this project. ❑v AYES. See Step 2 below. Approval )-f the Public Works Department is required prior to issuance of a Building Permit. 6 .(� N;A,,.+t bw,i St✓ux-t- ❑NO. Applicant certifies that o trees will be removed for this project. YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. -tree 4tAweL1 0 ermA KCL4- Io-LZ" L4 Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Attach Tree Removal Application if trees are to be removed or relocated. Address and contact information of person to receive all correspondence regarding this application(please print). Name: S Mailing Address: 91c 5 Telephone: CtOy- u I-505I Fax: 61()+0LJ1-(0 t 0'y E-Mail:rkI*1e I i4C !61Ve_ � Co/lti 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 •Fax: (904)247-5845 •http://www.ci.atlantic-beach.fl.us Page 1 Revised 1/14/03 I hereby certify that I have read and examined this application and attached documentation and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the go erning of construction o the performance of construction of the property. I understand that the issuance of this permit is contingent upon the a information being a and correct and that the plans and supporting data have been or shall be provided as required. Signature of Owner: Date: AS TO OWNER: Sworn to and subscribed before me this day of ,20 , State of Florida, County of Duval CYNTHIA K. MARRS Notary's Signature: Notary Public, State of Florian, ❑ Personally known My comm. exp. June 27, 2009 M?"Produced identification Comm.No. DD 445189 Type of identification produced FLOG�i . C)L - Signature of Contractor: Date: `7 a-1 I bb AS TO CONTRACTOR: r Sworn to and subscribed before me this 1 day of ,20 State of Florida,County of Duval CYNTHIA K. MARRS Notary's Signature: V, Notary Public, State of Florida Personally known My comm. exp. June 27, 2008 ❑ Produced identification Comm. No. DD 445189 Type of identification produced 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atlantic-beach.fl.us Page 2 Revised 1/14/03 Y EOwner's Name: BARKER BRYAN C& LEAH D Real Estate Number: 170124 0000 Property Address: 620 BEACH AV Mailing Address:1225 SELVA MARINA CR City: ATLANTIC BEACH ATLANTIC BEACH , FL Zip: 32233 Zip: Unit Number: 32233-5525 2006 Exempt Value: $0.00 PARCEL DESCRIPTION Property Use: 0100 SINGLE FAMILY JFW7an7sactlon Date: 4/25/1996 Transaction price displayed is based on the actual amount of Legal Description: 16-2S-29E DANIEL&HACKETT Transaction Price: $328,300.00 documentary stamps paid at the R/P BLK 16 ATLANTIC BEACH - LOT 3 time of recording.The current rate is 70 cents per$100. Neighborhood: 940907 BEACH AVE NBHD Section/Township/Range: 16-2S-29E No. Buildin s: 1 Official Record Book and Page: 083340418 Heated Area: 2425 Map Tile: 9416 Exterior Wall: Wood on Sheathing VALUES AND TAXES FROM 2005 CERTIFIED TAX ROLL Land Value: $283,020.00 Taxing Authority: USD3 Class Value: $0.00 JFCo7u7nty Tax: $3,308.24 Improvements: $237,200.00 School Tax: $4,163.84 Market Value: $520,220.00 District Tax: $1,559.31 Assessed Value: $520,220.00 Other Tax: $260.37 Exempt Value: $0.00 Voted Tax: $219.01 Taxable Value: $520,220.00 IF- ISr. Exempt: $0.00 Sr. Taxable: $0.00 IFTotal Tax: $9,510.77 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 06-00034039 Date 10/10/06 Property Address . . . . . . 620 BEACH AVE Application type description POOL Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ----------------------------------------------------------------------------- Application desc renew permit # 06 31960 ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BARKER THE BATTS COMPANY 620 BEACH AVENUE 1602 NORTH THIRD STREET ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 246-2455 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 35. 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/08/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 35 . 00 35 . 00 . 00 .00 Plan Check Total . 00 . 00 . 00 .00 Grand Total 35 . 00 35 . 00 . 00 . 00 u� htV U6 PERT IS APPROVED ONLY IN ACCORDANCI _-�. yr niLAN'TIC BEACH ORDINANCES AND TAE FLORIDA BUILDING CODES. ri�Ulr %- ff r :) r City of Atlantic Beach - 800 Seminole Road -Atlantic Beach,Florida 32233 Phone: (904)247-5800 - Fax: (904)247-5805 - http://www.coab.us ORDER of the Community Development Board for the City of Atlantic Beach, Florida APPLICANT: Bryan and Leah Barker 1225 Selva Marina Circle Atlantic Beach, Florida 32233 FILE NUMBER: ZVAR-2008-01 DATE OF HEARING: January 15, 2008 ORDER GRANTING REQUEST The above referenced Applicants requested a Variance from Section 24-157 of the Land Development Regulations to permit a 6-foot high fence to be constructed on the property line along the Sixth Street side of a property located at 620 Beach Avenue. On, January 15, 2008 said request was considered at a public hearing by the Community Development Board for the City of Atlantic Beach. Having considered the application, supporting documents and comments by the Applicant, the Community Development Board, approved the request, finding it to be consistent with Chapter 24-64 of the Land Development Regulations. NOW THEREFORE, the Community Development Board hereby GRANTS this request to permit a 6-foot high fence to be constructed on the property line along the Sixth Street side of a property located at 620 Beach Avenue, subject to: • Approval shall be required by the Public Safety Department confirming that the fence, as proposed, shall provide no obstruction to clear vehicular sight distance at adjoining intersections, and • the fence shall be designed, constructed with insets and landscaped as substantively represented within the attached drawing and as verbally represented during the public hearing. DATED THIS DAY OF 2- , 2008. The undersigned certifies that the above Order of the Community Development Board is a true and correct rendition of the Order adopted by said Board as the same appears in the record of the Community D velopment Board minutes. Community DevelOpment Director s OCEAN 130ULEVAR19 'u e'F 3 L 0 3 A n _ r r _ _ _ r r r J=- o VARIANCE REQUIRED rn a E m Y v $ m 1 Ch � m I — � o N 1 q 1 X p S z C7 � m � o I ca x 1 I CD x x rjl 4 rn Z 1 I I I PEACH AVENUE 73 r ` r-• � s� 4 �1 Chi a 3 mss. Ly r 3 7. LO �1 �CTRTV � V �'J.-� J..•� r-r? �� 7Z T�r r C 4 i yLT ft, AGENDA ITEM 6.b �S r J J S) COMMUNITY DEVELOPMENT STAFF REPORT January 15, 2007 Public Hearing ZVAR-2008-01, Barker residence To: Community Development Board From: Planning, Zoning and Community Development Department Date: January 7, 2008 Subject: ZVAR-2007-08 Applicant: Bryan and Leah Barker 1225 Selva Marina Circle Atlantic Beach, Florida 32254 Request: Variance from Section 24-157 of the Land Development Regulations to permit a 6-foot high fence to be constructed on the property line along the Sixth Street side of a corner lot located at 620 Beach Avenue. �► f il III��IIf f(Iill� ���► 40 Staff Comments: The subj ect property is currently being redeveloped with a new single-family residence. (A Variance was granted in April of 2006 to allow the new house to be reconstructed in the footprint of the previously existing nonconforming structure.) The property consists of three platted lots with street frontage on three sides. The front of the new home faces Beach Avenue, and the rear of the home faces Ocean Boulevard. A new swimming pool is under construction on the rear(west) side of the lot. The Applicants wish to enclose the rear of the property with a six-foot fence,which is permitted at the rear of atypical residential lot where not adjoining a street right-of-way. The fence regulations require that a 6- foot high fence be setback from the property line a distance of 10-feet. (A 4-foot high fence would be permitted on the property lines provided that it did not interfere with clear sight distance at the street intersection.) This request seeks approval to construct a six-foot high fence along the Sixth Street side property line for a distance of approximately 106 feet. The fence would comply with the fence regulations on the Ocean Boulevard side of the property. The primary purpose of the 10-foot fence setback on corner lots is to prohibit fences from interfering with clear sight distance at intersections. In this case, Sixth Street pavement edge is set back a distance of almost 12-feet from the property line, effectively creating this needed sight clearance. The secondary purpose of this setback is to prevent corner lots from appearing as walled compounds. Staff recognizes,however,that this issue can be substantively addressed with proper fence design. Also, property owners are entitled to some degree of privacy within their back yards, and this is difficult to achieve on a property with street frontages on three sides. The application also states that the grade of this property slopes approximately 1-foot from the pool to the sidewalk. The Applicants have the option to construct a six-foot high fence the required 10-foot distance from the property line, but have objected stating that this would render a 10-foot by 106-foot section of their rear yard un-useable. Staff has observed that such areas of a yard, which are between a fence and a street tend to be poorly maintained, or used for parking particularly where located near the beach, since property owners often do not perceive these areas as part of their yard. This would not be a desirable end- result. The Community Development Board during the previous five years has granted three similar Variances for six-foot high fences along street sides where privacy was an issue, although each of these involved much smaller properties. Staff does not object to approval of this Variance, subject to the below stated conditions and other conditions as the Community Development Board may deem appropriate. 2 t SUGGESTED ACTION FOR APPROVAL The Community Development Board may consider a motion to approve this request for a Variance from Section 24-157 of the Land Development Regulations to permit a 6-foot high fence to be constructed on the property line along the Sixth Street side of a property located at 620 Beach Avenue, subject to: (Add other conditions as may be appropriate.) • Approval shall be required by the Public Safety Department confirming that the fence, as proposed, shall provide no obstruction to clear vehicular sight distance at adjoining intersections. (This is required in any case.) • The fence shall be designed, constructed and landscaped as represented within the attached drawing, and upon finding: ❑ 1. There are exceptional topographic conditions of or near the property. ❑ 2. There are surrounding conditions or circumstances impacting the property disparately from nearby properties. ❑ 3. There are exceptional circumstances preventing the reasonable use of the property as compared to other properties in the area. ❑ 4. There are regulations, which were enacted after platting or after development of the property or after construction of improvements upon the property, that have onerous effect upon current use and development of the property. ❑ 5. The irregular shape of the property warrants special consideration. ❑ 6. The lot is a substandard size warranting a Variance in order to provide for its reasonable Use. SUGGESTED ACTION FOR DENIAL The Community Development Board may consider a motion to deny this request for a Variance from Section 24-157 of the Land Development Regulations to permit a 6-foot high fence to be constructed on the property line along the Sixth Street side of a property located at 620 Beach Avenue, upon finding: ❑ 1. There are no exceptional topographic conditions of or near the property. ❑ 2. There are no surrounding conditions or circumstances impacting the property disparately from nearby properties. ❑ 3. There are no exceptional circumstances preventing the reasonable use of the property as compared to other properties in the area. ❑ 4. ThEre are no regulations enacted after platting or after development of the property --r after construction of improvements upon the property having an onerous effect upon existing use and development of the property. ❑ 5. The lots are not of irregular shape of the property warranting special consideration. F-16. The lots are not of substandard size warranting a Variance in order to provide for the reasonabie Use of the property. 3 � ter..., t � rr �•. _ ;�`; ,._ -'" - - -__. _. t , l " " f z � f n E - 11r(� - LA �- 1 t - .r / t y j v ( ' ZE •+"'1 1 Itf rr J �4��r��.r Arl A�^.\� �!.\ ��\� ... r U � nNIAV HV � � i I I I I �d m� x= � 1 i1 1 I o �-- 1 v.s aQ �- }�mr W N o x o ( � d N i 0 W � w � a Z V) InE 6'+ 3 u7 N 1 — — — — — — — aminMM 3ONV18VA v — u c v u. c 0 m c n a � VA11nOO N V 1 0 g a MAP SHOWING SURVEY OF LOTS 1, 2 AND 3, BLOCK 16, DANIEL & HACKETT REPLAT, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 5, PACE 69 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. LOT 5 1 a I LOT 4 0 w a FOUND 3/4" r FOUND 1/2" IRON PIPE S89'47'1 7"E V 161.34'(FIELD) IRON PIPE > 3 NO 10 N 90'00'00" E 161.66' NO ID a p .88' ,/ 53.88 'm 0 9Y 53 r N 53.88' 5014* 28.s' �yti w U � O o: a 3.5' w O CONCRETE O O ts9' BLOCK 6.7' w O FOUNDATION O!:�- ORESIDENCE On w r' NO. 620 a, _ rn w CONCRETE z J PORCH I LLI 6.Y O LOT 1LOT 2 LOT 3 a.s i:: OO �7 Q W Q �N TT O O IBJ 9'9 '0' FINISHED FLOOR Z z O ELEVATION=16.6 TOP OF BLOCK \J W 5.8' W 8 ' _ 24.,• m O _ CONCRETE PORCH �. 5s' m za.+' 9-7- 53.00' 7'53.00' - 53.00' 53.00' FOUND 1/2" N 9000'00" W 159.00' FOUND 3/4" IRON PIPE N90'00'00"W 158.90'(FIELD) IRON PIPE NO 10 NO ID NOTES. SIXTH STREET 1. THIS IS A BOUNDARY SURVEY. 40' RIGHT OF WAY PAVED 2. BEARINGS BASED ON THE NORTH RIGHT OF WAY LINE OF 6TH STREET. 3. NORTH PROTRACTED FROM PLAT. 4. ANGLES DETERMINED IN THE FIELD. THIS SURVEY WAS MADE FOR THE BENEFIT OF: THE PROPERTY SHOWN HEREON APPEARS TO LIE BRYAN C. BARKER AND LEAH D. BARKER. IN FLOOD ZONE "X" (AREA OUTSIDE 500 YEAR FLOOD PLAIN) AS WELL AS CAN BE DETERMINED FROM THE FLOOD INSURANCE RATE MAP COMMUNITY PANEL NO. 1 20077 0001D, REVISED APRIL 17, 1989, FOR THE CITY OF ATLANTIC BEACH, DUVAL COUNTY, FLORIDA. "NOT VALID WITHOUT THE SIGNATURE AND DOA W. BOAiWRIGHT, P.S.M. THE ORIGINAL RAISED SEAL OF A FLORIDA FINISHED FLOOR ELEVATION FLORIDA LIC. SURVEYOR and MAPPER No. LS 3295 LICENSED SURVEYOR AND MAPPER." ADDED JANURARY 4, 2007 FLORIDA LIC. SUiRVEYINO & MAPPING BUSINESS No. LB 3672 CHECKED BY: BOATWRIGHT LAND SURVEYORS, INC. DATE: 3, DRAWN BY: JJG NOVEMBER 2006 FILE: 06-1477 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FLORIDA 241-8550 SHEET i OF 1 7 APPLICATION FOR A VARIANCE City of Atlantic Beach • 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 • FAX (904)247-5845 • http://www.coab.us Date December 21, 2007 File No. ZVAR-2008-01 1. Applicant's Name Bryan & Leah Barker 2. Applicant's Address 1225 Selva Marina Circle 3. Property Location 620 Beach Avenue 4. Property Appraiser's Real Estate Number 170123 0000 5. Current Zoning Classification RG-1 6. Comprehensive Plan Future Land Use designation RL 7. Provision from which Variance is requested Section 24-157 (c) Corner Lot fence height 8. Size of Parcel-100 I x 1591 = 15 , 900 sgft / 0 .36ac 9. Homeowner's Association or Architectural Review Committee approval required for the proposed construction. ❑Yes ®No (If yes,this must be submitted with any application for a Building Permit.) 10. Statement of facts and site plan related to requested Variance,which demonstrates compliance with Section 24-64 of the Zoning, Subdivision and Land Development Regulations, a copy of which is attached to this application. Statement and site plan must clearly describe and depict the Variance that is requested. 11. Provide all of the following information: a. Proof of ownership (deed or certificate by lawyer or abstract company or title company that verifies record owner as above). If the applicant is not the owner,a letter of authorization from the owner(s)for applicant to represent the owner for all purposes related to this application must be provided. b. Survey and legal description of property for which Variance is sought. c. Required number of copies: Four (4), except where original plans, photographs or documents lamer than 11x17 inches are submitted. Please provide eieht (8)copies of any such orisinal documents. d. Application Fee($150.00) I HEREBY CERTIFY THAT ALL INFORMATION PROVIDED WITH THIS APPLICATION IS CORRECT: Signature of owner(s)or authorized person if owner's authorization form is attached: Printed or typed name(s): Bryan Barker Leah Barker Signature(s): *see note below ADDRESS AND CONTACT INFORMATION OF PERSON TO RECEIVE ALL CORRESPONDENCE REGARDING THIS APPLICATION Name: Chris Lambertson, Elite Homes Mailing Address: 2038 Beach Avenue Atlantic Beach, FL 32233 Phone: 349-2803 (cell) FAX: 241-9748 E-mail:chris@e1itehomesf1 .com Instructions to apply for a Variance Variance requests are considered and acted upon during public hearings before the Community Development Board at their regular monthly meetings, which are held the third Tuesday of each month, unless otherwise scheduled. Meetings are held at City Hall in the City Commission Chambers at 7:00 pm. The deadline for filing a Variance application, in order to be heard at the monthly meeting, is 5:00 pm on the first Monday of each month. Applications should be submitted to the Planning and Zoning Department located at City Hall. In order for a Variance application to be scheduled for public hearing, the application must be complete. All required information must be provided, and the required fee must be paid. (Variance fees are not refundable in the event that the Variance request is denied.) Once the required fee and a complete application are submitted, the request will be scheduled for the next available public hearing. An advertised notice of the hearing will be published in the newspaper, and an orange zoning sign will be placed upon the property to notify neighboring residents that a Variance request will be considered. Before filing an application for a Variance, it may be useful to read and understand the following definition and requirements from the City's Land Development Regulations related to Variances. A Variance may be approved by the Community Development Board only when consistent with these provisions. Section 24-17. Definition of a Variance. A Variance shall mean relief granted from certain terms of this Chapter. The relief granted shall be only to the extent as expressly allowed by this Chapter and may be either an allowable exemption from certain provision(s) or a relaxation of the strict, literal interpretation of certain provision(s). Any relief granted shall be in accordance with the provisions as set forth in Section 24-64 of this Chapter, and such relief may be subject to conditions as set forth by the City of Atlantic Beach. Sec. 24-64. Variances. A Variance may be sought in accordance with this Chapter. Applications for a Variance may be obtained from the Community Development Department. A Variance shall not reduce minimum Lot Area, minimum Lot Width or Depth; and shall not increase maximum Height of Building or Impervious Surface Area as established for the various Zoning Districts. Further, a Variance shall not modify the Permitted Uses or any Use terms of a property. (a) Application. A request for a Variance shall be submitted on an application form as provided by the City and shall contain each of the following. (1)a complete legal description of the property for which the Variance is requested. (2) a reasonable statement describing the reasons for the Variance. (3) a survey or Lot diagram indicating setbacks; existing and proposed construction, as well as other significant features existing on the Lot. (4) the signature of the owner, or the signature of the owner's authorized agent. Written authorization by the Owner for the agent to act on the behalf of the property owner shall be provided with the application. (b) Public Hearing. Upon receipt of a complete and proper application, the Community Development Director shall within a reasonable period of time schedule the application for a public hearing before the Community Development Board following required public notice. At the public hearing, the applicant may appear in person or may be represented by an authorized agent. (c) Grounds for denial of a Variance. No Variance shall be granted if the Community Development Board, in its discretion, determines that the granting of the requested Variance shall have a materially adverse impact upon one or more of the following. (1) light and air to adjacent properties. (2) congestion of Streets. (3) public safety, including risk of fire, flood, crime or other threats to public safety. (4) established property values. (5) the aesthetic environment of the community. (6) the natural environment of the community, including Environmentally Sensitive Areas, wildlife habitat,Protected Trees, or other significant environmental resources. (7) the general health,welfare or beauty of the community. Variances shall not be granted solely for personal comfort or convenience, for relief from financial circumstances or for relief from situations created by the property owner. The following paragraph sets forth reasons for which a Variance may be approved. Please check the circumstances that apply to your request and briefly describe in the space provided. (d) Grounds for approval of a Variance. A Variance may be granted, at the discretion of the Community Development Board,for the following reasons. (1) exceptional topographic conditions of or near the property. The lot slopes west and the grade falls -1 ' over the distance from pool to sidewalk. This effectively lowers any fence for privacy the same amount . Thus a 61fence would only yield a 51fence in terms of privacy. EJ (2) surrounding conditions or circumstances impacting the property disparately from nearby properties. ® (3) exceptional circumstances preventing the reasonable use of the property as compared to other properties in the area. lot is a double frontage through-lot (Beach Av to Ocean Bv, and is also a corner/end lot with frontage on 6th St . See additional comments on following page. ❑ (4) onerous effect of regulations enacted after platting or after development of the property or after construction of improvements upon the property. 1 ❑ (5) irregular shape of the property warranting special consideration. ❑ (6) substandard size of a Lot of Record warranting a Variance in order to provide for the reasonable Use of the property. (e) Approval of a Variance. To approve an application for a Variance, the Community Development Board shall find that the request is in accordance with the preceding terms and provisions of this Section and that the granting of the Variance will be in harmony with the Purpose and Intent of this Chapter. (f) Approval of Lesser Variances. The Community Development Board shall have the authority to approve a lesser Variance than requested if a lesser Variance shall be more appropriately in accord with the terms and provisions of this Section and with the Purpose and Intent of this Chapter. (g) Nearby Nonconformity. Nonconforming characteristics of nearby Lands, Structures or Buildings shall not be grounds for approval of a Variance. (h) Waiting period for re-submittal. If an application for a Variance is denied by the Community Development Board, no further action on another application for substantially the same request on the same property shall be accepted for 365 days from the date of denial. (i) Time period to implement Variance. Unless otherwise stipulated by the Community Development Board, the work to be performed pursuant to a Variance shall begin within six (6) months from the date of approval of the Variance. The Community Development Director, upon finding of good cause, may authorize a one time extension not to exceed an additional six (6) months, beyond which time the Variance shall become null and void. (j) A Variance, which involves the Development of Land, shall be transferable and shall run with the title to the Property unless otherwise stipulated by the Community Development Board. Additional comments: Variance sought for 6 ' fence on property line on 6th Street . Fence would start 10 ' in from property line on Ocean Bv, thus giving an excellent sight triangle at the corner of 6th and Ocean. Also, there is a large City right-of-way between 6th Street and property line which would create a buffer so that the fence would be in scale with the intent of the code. The right-of-way would be landscaped, also creating a smooth transition. Also, the grade of the land slopes toward Ocean By about one (1) foot, which reduces the effect of the fence for privacy, creating a hardship. "11 CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Date: 7. J5 /• o4� Address (Q o? 0 ,6 EA C H X V,9:' Heated Square Footage Yq1.5' @ $ per sq ft= $ --1-61-,4L -750 -7 Gar �l�hed @ $ per sq ft= $ (p C org9L ��rAi /c.y� Carport/Porch @ $ per sq ft= $ p Tip► / - 9 8 Deck @ $ per sq ft= $ Patio @ $ per sq ft= $ TOTAL VALUATION: $ fav 000 $ Total Valuation 1St $ Remaining Value $ . per thousand or portion thereof CONSTRUCTION TYPE: TOTAL BUILDING FEE $ ZONING: + %2 Filing Fee $ FLOOD ZONE: (2)Fireplaces @ $35.00 $ 70- so IMPERVIOUS SURFACE: BUILDING PERMIT FEE $ WATER IMPACT FEE $ /a0 . 00 SEWER IMPACT FEE $ WATER METER/TAP $ CAPITAL IMPROVEMENT$ SEWER TAP $ C (40Q RADON HRS .0050 $ STATE RADON (6010 $ SECTION H PAVING( ) $ CROSS CONNECTION $ ST(9?08) SURCHARGE $ CITY SURCHARGE (89y 6)$ OTHER $ GRAND TOTAL DUE: $ 1/13/03 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD J + =r ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 06-00034007 Date 10/02/06 Property Address . . . . . . 615 617 OCEAN BLVD Application type description DEMOLITION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------- ------------------- --------------------------- ----------------------- Application desc DEMO FOR NEW HOME ------- ------------------------------------------------ ---- ----------------- Owner Contractor ------------------------ ------------------------ BARKER ELITE HOMES INC. 77 19TH STREET ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 ---------------------------------------------------------------------------- Permit . . . . . . DEMOLITION PERMIT Additional desc . . Permit Fee . . . . 100 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/31/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due -- --------------- ---------- ---------- ---------- - --------- Permit Fee Total 100 . 00 100 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 100 . 00 100 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ti ,Ly r CITY OF ATLANTIC BEACH 800 SENIINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 06-00034008 Date 10/02/06 Property Address . . . . . . 620 BEACH AVE Application type description DEMOLITION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------------------- Application desc DEMO FOR NEW HOME -- ----------------------------------------------- --------- Owner Contractor -- --- ------------------- ---------- -------------- BARKER ELITE HOMES INC. 620 BEACH AVENUE 77 19TH STREET ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 ------------------------------ ------------------------------- Permit . . . . . . DEMOLITION PERMIT Additional desc . . Permit Fee . . . . 100 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/31/07 ------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------- ------- -------- -- ---------- ---------- ---------- Permit Fee Total 100 . 00 100 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 100 . 00 100 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH s DEMOLITION PERMIT APPLICATION 1 r Date: "I c')(0 a a3 Job Address: 3 Owner of Property: F Address: �J � 4.rI UI,kTelephone: Legal Description: Block Number: 110 Lot Number: Zoning District: Contractor: G State License Number: , 0 59/90 Contractor'sAddress: Telephone: - y(- Fax: ` Describe proposed use and work to be done: Present use of land or building( All s Is approval of Homeowner's Association or other private entity required? If yes,please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material or the removal of any trees? ❑ O. Applicant certifies that no change in site grade or fill material will be used on this project. [ YES. See Step 2 elow. ApprovalEETemoved c Works)Department is required prior to issuance of a Building Permit. V (�i „Vy�Cc� ❑ NO. Applicant certifies thata tfor this project. QrYES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Remov`qI PermiV to be reviened ty th� ation Bo�hi�ee��o times each month. UAM Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Attach Tree Removal Application if trees are to be removed or relocated. Address and contact information of person to receive all correspondence regarding this application(please print). Name: IYC5 Mailing Address: Q.10 114, 6V CUO n 3a0� b Telephone: q bq-c)q 1 �� Fax: g0L4-cD(f1—(P 1 W E-Mail:l hr 0 6)P-(,46)OX541 Wk, 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 -Fax: (904)247-5845 •http://www.ci.atiantic-beach.fl.us Page 1 Revised 1/14/03 I hereby certify that I have read and examined this application and attached documentation and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the g ming of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the ve information be' true and correct and that the plans and supporting data have been or shall be provided as required. Signature of Owner: Date: AS TO OWNER: �} r Sworn to and subscribed before me this ` day of ,20 6(o . State of Florida,County of Duval �[ Notary's Signature: MN4&-,.- ❑ Personally known [�] roducd identification Type of identification produced (Of l do— oL— Signature of Contracto . .7,Z��� Date: -1�W AS TO CONTRACTOR: Sworn to and subscribed before me this c day of 20� State of Florida,County of Duval Notary's Signature: 1 Personally known ❑ Produced identification Type of identification produced 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 -Fax: (904)247-5845 -http://www.ci.atlantic-beach.fl.us Page 2 Revised 1/14/03 Owner's Name: BARKER BRYAN C&LEAH D Real Estate Number: 170123 0000 Property Address: 615 OCEAN BV Mailing Address:1225 SELVA MARINA CR City: ATLANTIC BEACH ATLANTIC BEACH , FL Zip: 32233 Zip: Unit Number: 32233-5525 2006 Exempt Value: $0.00 PARCEL DESCRIPTION Property Use: 0891 DUPLEX Transaction Date: 1/15/2003 Transaction price displayed is based on the actual amount of Legal Description: 9-35 16-2S-29E DANIEL& Transaction Price: $950,000.00 documentary stamps paid at the HACKE17 R/P BLK 16 ATLANTIC BEACH - LOTS 1,2 time of recording.The current rate is 70 cents per$100. Neighborhood: 8411.04 (0800'S)ATLANTIC BEACH [section/Townshi /Ran e: 16-2S-29E ifio. Buildings: 1 Official Record Book and Page: 108791099 Heated Area: 2316 Map Tile: 9416 Exterior Wall: Concrete Block VALUES AND TAXES FROM 2005 CERTIFIED TAX ROLL Land Value: $540,000.00 Taxing Authority: USD3 Class Value: $0.00 County Tax: $4,920.19 Improvements: $233,700.00 School Tax: $6,192.69 Market Value: $773,700.00 IlDistrict Tax: $2,319.09 Assessed Value: $773,700.00 110ther Tax: $387.24 Exempt Value: $0.00 Voted Tax: $325.73 Taxable Value: $773,700.00 Sr. Exempt: $0.00 Sr. Taxable: $0.00 Total Tax: $14,144.94 k CITY OF ATLANTIC BEACH DEMOLITION PERMIT APPLICATION Date: Job Address: (P 1-7 Cua4l_. 61vd,, Q,�ICYri-h�c QC,G�r r-(- �ow,33 Owner of Property: IN t Address: Q ephone: U G@-131q Legal Description: Block N mber: ((p Lot Number: 1 "2 Zoning District: Contractor: State License umber: c6c�n 5-goo Contractor's Address: Q t) M �P. ,5 Telephone: Q04—at4 P5V5 Fax: (— (p I W Describe proposed use and work to be done: D2 n10 g s r ems, I��N�c Present use of land or building(s): (2eA 4Qp _+tJ Is approval of Homeowner's Association or other private entity required? NO If yes,please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material or the removal of any trees? ❑N Applicant certifies that no change in site grade or fill material will be used on this project. [XS. See Step 2 below. Appxoval of the Public Works Department is required prior to issuance of a Building Permit. tlern�,t tiu� h¢ s ❑NO. Applicant certifies tf'►at no trees will be removed for this project. WYES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. -rXC,A0e"&V&J P� �� bkZv :�5-UQZ Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Attach Tree Removal Application if trees are to be removed or relocated. Address and contact information of person to receive all correspondence regarding this application(please print). Name: A A �11ne "y . Mailing Address: 1Q'Ib Telephone: �a`1 F E-Mail: 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 •Fax: (904)247-5845 -http://www.ci.atlantic-beach.fl.us Page 1 Revised 1/14/03 I hereby certify that I have read and examined this application and attached documentation and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with,whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the gov ruing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the a e information bei true and correct and that the plans and supporting data have been or shall be provided as required. (] n Signature of Owner: Date: "1 AS TO OWNER: /}}� Sworn to and subscribed before me this 1 day of ,20 . State of Florida,County of Duval Notary's Signature: WHIA K. MARRS �mtary Public, State of Florida my comm. exp. June 27, 2009 ❑,Personally known Comm. No. DD 445189 Ib rroduced identification r Type of identification produced RUr(CI'x DL- Signature of Contractor: Date: �► '���- p AS TO CONTRACTOR: Sworn to and subscribed before me this QV ' — day of_ ,200,Q. State of Florida,County of Duval Notary's Signature: ` CYNTHIA K. MARRS Notary Public, State of FloridaPersonally known My comm. exp. June 27,2009 Produced identification Comm. No. DD 445189 Type of identification produced 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 •Fax: (904)247-5845 -http://www.ci.atiantic-beach.fl.us Page 2 Revised 1/14/03 Owner's Name: BARKER BRYAN C&LEAH D ERealtate Number: 170123 0000 Property Address: 615 OCEAN BV Mailing Address:1225 SELVA MARINA CR City: ATLANTIC BEACH ATLANTIC BEACH , FL Zip: 32233 Zip: Unit Number: 32233-5525 2006 Exempt Value: $0.00 PARCEL DESCRIPTION Property Use:0891 DUPLEX ITransaction Date: 1/15/2003 Transaction price displayed is Legal Description: 9-35 16-2S-29E DANIEL& based on the actual amount of HACKETT R/P BLK 16 ATLANTIC BEACH -LOTS 1,2 Transaction Price: $950,000.00 documentary stamps paid at the time of recording.The current rate is 70 cents per$100. Neighborhood: 8411.04(0800'S)ATLANTIC BEACH Section/Township/Rane: 16-2S-29E No. Buildings: 1 Official Record Book and Page: 108791099 IlHeated Area: 2316 IlMap Tile: 9416 =lExterior Wall: Concrete Bkxk VALUES AND TAXES FROM 2005 CERTIFIED TAX ROLL Land Value: $540,000.00 Taxing Authority: USD3 Class Value: $0.00 JjCounty Tax: $4,920.19 improvements: $233,700.00 School Tax: $6,192.69 Market Value: $773,700.00 District Tax: $2,319.09 Assessed Value: $773,700.00 10ther Tax: $387.24 Exempt Value: $0.00 JIVoted Tax: $325.73 Taxable Value: $773,700.00 Sr. Exempt: $0.00 Sr. Taxable: $0.00 Total Tax: $14,144.94 -Aj ELITE HOMES, ING December 5, 2006 City of Atlantic Beach Dave Hufstetler- City Building Official of Atlantic Beach 800 Seminole Rd. Atlantic Beach, FL 32233 RE: Windows for 620 Beach Ave. Permit# 06-00031959 Dear Mr. Hufstetler: In lieu of using Pella Windows, which we originally submitted product approval numbers for, we will be using Anderson Windows. The product approval numbers are listed below. Woodwright Double Hung FL 1091.5 Woodwright Transom FL 1092.6 Outswing Double Door FL 1097.7 Fixed Picture FL 1156.5 Casement Single FL 1086.4 Casement Double FL 1097.9 Awning FL 1085.1 KML - Oval FL3947.2 Thank you, Chris LambertsonFILE President, Elite Homes, Inc. COPY CL/ckm Cbrls Lambertson 241-5251 Robert Olson 249-2431 ELITE HOMES, INc. TO: Dave Husstetler FROM: Christopher Lambertson 6el- DATE: November 3, 2006 RE: Revised Engineering for 620 Beach Ave. o� Chris Lambertson 2415251 • Robert Olson 249-2431 X*, CITY OF ATLANTIC BEACH zSl 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 J;31 INSPECTION EMAIL REQUEST: Building-dept d_..coab.us Application Number . . . . . 07-00001216 Date 8/24/07 Property Address . . . . . 620 BEACH AVE Application type description ELECTRIC ONLY Property Zoning . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc early power ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ Barker KNIGHT ELECTRIC LLC 620 BEACH AVENUE 910 11TH AVE S ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 247-9884 ---------------------------------------------------+------------------------- Permit ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 300 . 00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/20/08 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 300. 00 300 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 300 . 00 300 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. Flub 24 07 ll: 16a Knight Electric 904 247 9843 p• 1 EARLY POWER AGRE&KENT & RELEASE ` v CITY OF ATLANTIC BEACH iiia•i Electric power is requested now under the eonditiom and terns of thds fully amited Ar eermeat&Release roao 8 ewe Permit No. ' 3`-.4�� Secvioe Type(Orele One)- Ovedread F9d9;;aa-) We,the undersigned General Contractor and F:iec xum,understand and same: I. `°Ssrly Pow�es" is for our a W- " veaience, l roWned Codes and does �t substmc for Final etas or thefeof must bas issuedbeoccupancy, andassuchisatthe n ofthe Binsal. 2. The City of Atla>riie Beach v✓itl eQaelot s spociat ' prier�*0�Y power encrgimaittg_ Alt magi inspechaas must have prior Approval.ineladm g omnecdons. 3. Occupancy qr usa Such new 6eforo a formal i Anstftby", fent use of the cady e[eaCnn service. is p�ohib" and '1`ha C' of c Beam lXdinv s. A of us Agtnemeut sWil in a ngaeet for pcvmpt irmayst Of service abet atvosly-£mRr w Wdee. 4. "Eariy Powe'release apthority is the El=Mcian=&,or the nodi not occur bcijote: AL �q devdcosq ora i�tallei(ar blo�saef+ely. b. Pcoanl►►leoe an�noel Dower aa�(ta6elaaig required at tm iaspectsoa). c. Service connection g��ng b d. The electric system bas§atse3y� ehxhiaal check. e. Menet dxtn is t1yy with address. f_ Temporary s nuanfoers duptayed numbers are required far CJO). 5.. Pay l .admkistra tion feej any reinspection bees and any oubtaix ging ragaueats orost ba satislsod prior tore ease. 6. This fully compIMM form is to be submitted to ttu Building DepaMneeat by hand,mail or f L 7. fttum such Agreemeats will not be acw*ted fi=x those wdm viakto nay one of the above items. CON 18ACTO�It DA= PRINT NAM >sLEMPLICM DATE 2 U7 PMT MOM 800 Seminot&Road..U=dcBew&M 32233 Phone;(904}247-5826- Fac(904)t7-Stt45 ht-M1-N —W,coab.us revised I t.29.06 , S \$`lr� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 t J X31 ' Application Number . . . . . 06-00034245 Date 11/09/06 Property Address . . . . . . 620 BEACH AVE Application type description ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc NEW SERVICE - 300 AMPS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ KNIGHT ELECTRIC LLC 13997 BEACH BLVD JACKSONVILLE FL 32224 (904) 247-9884 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . Permit Fee 125 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/08/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 125 . 00 125 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 125 . 00 125 . 00 . 00 . 00 LA PERWr.1S.APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BURMING CODES. fns CITY OF ATLANTIC BEACH y ELECTRICAL PERMIT APPLICATION C)6 , //�� Date: 012104 Property Address: /J(-r/4 Owner: !.) fr Telephone#-. Contractor: �/V+( E7 auptc L�L Telephone#: q7'9 Contractor Address: W97 947 A&A &d 94F/ 3ZZ z Fax#. Contractor§' ature: In consideration of permit given for doing the work as described in the abovc stetetnent,we hereby agree to perform said work in accordance with the attached plans and specifications which aro a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed thereat. Bu ing: Bui Type: ❑ Trailer Service: If other mn8tr„ction is er New iY Residence ❑ Temp. ❑ New being de on this building ❑ Old ❑ Commercial ❑ Sighs ❑ Increase Or site,list the building ❑ Re-wire ❑ Addition Sq.Ft. E3Repairtta- r � Conductor Size: AMPS; COPPER ALUMINUM Switch or RACE. �� Breaker AMPS 30U PH W 3 VOL U WAY 3 Existing Service RACE Size AMPS PH W VOLT WAY Meter Dumber Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED OPEN Receptacles CONCEALED .e.e PEN O Switches O Incandescent Fluorescent & M.V. Fixed 0.100 AMPS OVER BELL Appliances TRANSFER. Air H.P.RATING H.P.RATING CEILING KW-HEAT Conditioning COMP.MOTOR OTHER MOTORS AMPS HEAT Motors 0-1 H.P. VOLTAGE PH NO. OVER I H.P. PHS UNDER600V 0VER600V Transformers NO. KVA NO. KVA No.Neonf. Trans Ea. Si _ Miscellaneous W Seminole Road.Atlantic Beach,Florida 32233-5445 Phone:(904)247-5$80• Fax: (904)247-5845• htta://www.ci.atlAntic-I)each.o.us Revised 1/04 T 'Cl 0100_/ 17_Ln0 AR InO�n .�rn..o rw.• .... I+.. -.. _{�_ __._ _- - - City ofAtla t&Beach Pem*In omur on To: JEA Electric Order Fulfillment, (Fax No.: 665-7372) Attention: Carol SchweizerlLorie Craven,21 West Church St T4 (665-6521) Subject: City of Atlantic Beach Permit# Date: Service Address: Owner: Owner Phone: Electrician: fie 4,h 7 li e, Electrician Phone: q Type of Work: New Service _, M-Home Subfeed [� Increase Service [_] Heat & AC [� Repair Service [i] Other [ Rewire LJ Other Description: Temp Pole [ Service Type: (Overhead (Repair/Replace) [„],Underground(New Services) Building Use: [Residential ]Church "Environmental "M-Home ]Commercial "Other Other Use Description: Service Size: New Service: Amps: Volts: Phase: / Existing Service:Amps: Volts: Phase: E-mail:cravli0,jea.com or schwcmajea.corn or resom 'ea.com t HP Officejet 7410 Log for Personal Printer/Fax/Copier/Scanner Information Systems 904247-5$45 Aug 27 2007 9:34AM Last Transaction Date Time Type Identification Duration Panes result Aug 27 9:32AM Fax Sent 96657372 2:02 5 OK CITY OF ATLANTIC BEACH 800 SEAGNOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 06-00034244 Date 11/09/06 Property Address . . . . . . 620 BEACH AVE Application type description ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc temp-pole ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ KNIGHT ELECTRIC LLC 13997 BEACH BLVD JACKSONVILLE FL 32224 (904) 247-9884 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 70 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/08/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ----------- ---------- ---------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 70 . 00 70 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE Wrl ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. n� i�aiCITY OF ATLANTIC BEACH y ELECTRICAL PERMIT APPLICATION // �?� f Date: 1� 2 C)�c fl Property Address• W �� 1�-�c(i ��� Owner: IWC/- Telephone#- Contractor: K i J,J 1F t t-L C1021 L L L C Telephone#: 2`i "9Ff/ Contractor Address: (39 � F( 32e24 Fax#-. Contractor • atnre: In consideration of permit given for doing the work as described in the above statement,we hereby agree to perform said wait in accordance with the adaehed Plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Buik[itag: Building Type: ❑ Tatler Service: If other conshnction is ❑ New D Residence e' Temp. (3 New tag done on this building ❑ Old O Commercial D Signs D Increase Or site,list the buDdkig!?V-170751 F s ❑ Re-wire ❑ Addition Sq.Ft. ❑ Repair b-S"I S1 Conductor Size: AMPS: COPPER ALUMINUM Switch or RACE Breaker AMPS PH W VOLT WAY Existing Service RACE Size AMPS PH W VOLT WAY Meter Number Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED )( E OPEN Receptacles CONCEALED N�V 2 OPEN Switches Incandescent Fluorescent & M.V. Fixed 0.100 AMPS OVER BELT. Appliances TRANSFER. Air H.P.RATING H.P.RATING CEILING KW-HEAT Conditioning COMP.MOTOR OTHER MOTORS AMPS HEAT Motors 0-1 H.P. VOLTAGE PH I NO. OVER I H.P. PHS UNDBR600V OVER600V Transformers NO. KVA NO. KVA No.Neon Transf. ! Ea. Sign _ Miscellaneous W Seminole Road•Atlaatic Beach,Florida 32233-5445 Phone:(904)247-58811. Fax: (404)247-5845• Itttp-./twww.ci.atiantic-beach.[l.us Revised VO4 T •al C4-00_1L7_a.no n[t IIno�n A- - --- HP ORlcejet 7410 Log for Personal Printer/Fax/Copier/Scanner Information Systems 904247-5845 Nov 09 2006 10:51 AM Last Transaction Date Time Type Identification Duration Paces Result Nov 9 10:49AM Fax Sent 96654470 1:17 3 OK HP Officejet 7410 Log for Personal Printer/Fax/Copier/Scanner Information Systems 904-247-5845 Nov 21 2006 1:43PM Last Transaction Date Time Type Identification Duration Pagges Result Nov 21 1:42PM Fax Sent 96654470 1:12 3 OK CITY OF ATLANTIC BEACH 800 SE HNOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 INSPECTION EMAIL REQUEST: Building-dept(a..coab.us Application Number . . . . 07-00001216 Date 8/24/07 Property Address . . . . . . 620 BEACH AVE Application type description ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc early power ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ Barker KNIGHT ELECTRIC LLC 620 BEACH AVENUE 910 11TH AVE S ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 247-9884 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 300 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . - 2/20/08 ----------------------------------------------------------------------- Fee summary ChargedPaid Credited Due ----------------- -- ------- ---------- ---------- ---------- Permit Fee Total . 00 300 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 Grand Total 300 . 00 . 00 . 00 PERMff IS APPROVED ONLY IN ACCORDANCE WITH ALL C NTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. EmTE HOMES, INc c�P Elite Homes, Inc. 910 1 l th Ave. S. UI Jacksonville Beach,FL 32250 February 28,2007 Mr. Dave Hufstetler Building Official City of Atlantic Beach 800 Seminole Rd. Atlantic Beach, FL 32233 Dear Mr. Hufstetler: RE: Attic Insulation Per our conversation on 2/28/07 regarding permit 406-00031959,Elite Homes, Inc. will not be encapsulating the attic foam insulation per Florida Building Code section R314.2.3. Sincerely, Chris Lambertson President CL/ckm 41 /C 41P Cbris Lambertson 241-5251 Robert Olson 249-2431 �tLuului CITY OF ATLANTIC BEACH 2/07/08 Application Inquiry 10: 40: 15 Application number . . . . . : 08 00000087 Application status, date . . : PERMIT ISSUED 1/25/08 Property . . . . . . . . . . : 620 BEACH AVE RE number. . . . . . . . . . : 170124-0000- - NCR OLD ACCOUNT NUMBERS. . . : ABO1065 Zoning . . . . . . . . . . . : RG-1 RESIDENTIAL GEN 2 FAMILY Application type . . . . . . : FNCE FENCE PERMIT Application date . . . . . . . 1/17/08 Tenant number, name . . . . . Master plan number, rev'wd by: SLG Estimated valuation . . . . . 15000 Total square footage . . . . . 0 Public building . . . . . NO Work description, qty . . . . Pin number . . . . 312131 Application desc . . . . . . : INSTALL 6' WOODEN/BRICK & ALUM. FNCE Press Enter to continue. F3=Exit F5=Land inq F7 Appl names FS--Tracking inq F9 Bond inquiry F10=Fees Fll=Receipts F12xancel F13-=Val calcs F14=Ki.sc info F24=iore keys Date: May 23, 2006 To: City of Atlantic Beach From: Elite Homes Subject: Transfer of Permit Please transfer the permit for Bryan&Leah Barker at 620 Beach Ave. from Dean Davis Builders to Elite Homes, Inc. Thanku, k Bryan eah Barker Graham Shirley From: Kaluzniak, Donna Sent: Friday, July 28, 2006 3:06 PM To: Graham Shirley; Brugman Kerri; Matthews, Carlene Cc: Makowski, Stan Subject: 620 Beach Avenue Shirley, I got the calculations finished for this property. Only$120 in water impact fees- I'll send back the plans and the calculation sheets. The"Guest Cottage"will have to be metered and addressed separately from the main house. It will be on what is currently 615 Ocean Blvd. (Both 620 Beach Ave. and 615 Ocean are currently metered). I'm copying to Stan so he can figure out the addressing. I am assuming that Mr. Barker is combining the 2 pieces of property into one piece. The meter for 615 Ocean will probably stay in the same location, no matter which address it's given -just so Carlene will know what to do. -Donna Donna Kaluzniak Utility Director City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 PH: 904-247-5834 FAX 904-247-5843 dkaluzniak@coab.us 1 CITY OF ATLANTIC BEACH € 800 SENIINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 06-00033088 Date 5/30/06 Property Address . . . . . . 620 BEACH AVE Tenant nbr, name . . . . . . CONTRACTOR CHANGE Application description . . . SINGLE FAMILY RESIDENCE Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ BARKER ELITE HOMES INC. 620 BEACH AVENUE 77 19TH STREET ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 35 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 35 . 00 35 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 35 . 00 35 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 10 BUILD&G OFFICIAL w Graham Shirley To: Carper, Rick Subject: ' RE: Building Permit Approval From: Carper,Rids Sent: Friday,May 26,2006 3:24 PM To: Graham Shiriey Cc: Komorek,Cheryl Subject: Building Permit Approval Shirley,would you please enter Public Works approval for the following two permits: 06-33024(770 Paradise Lane)and 06-319%(620 Beach-Ave). Cheryl is working on entering comments from another review, but#ww two areiesel rly Thanks, Rick Ricky L. Carper, P.E. Director of Public Works/City Engineer City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 rcarper@coab.us PLEASE NOTE.- Florida has a very broad public records law. Your e-mail communications may be subject to public disclosure. 1� 4000, I JIJ CITY OF ATLANTIC BEACH Ill-Mv BUILDING PERMIT APPLICATION (New/Residential & Commercial) Date: 1 CJ Job Address: (o2D 3F-AC,*4 Art/L T1 C_ ?>&t"i _Y Owner's Name--tP N-1-J L&A-++ 12 25,,<Address: 17 ffift4WA Ciez 4J-iAWYit_ 0C-^C+J Phone: CID Lf J-y q JJU-3 Legal Description: Block Number: Lot Number: Zoning District Contractor: ' i_Lq-�� &#nF State License Number: .7 Address: Q Phone:.3_0 -,r-U43 jjo �2_5-1 City:_ Ji2_ 9C -State: *-I- Zip. Fax: IS q Describe proposed use and work to be done:t\)Q&-,a 4 Present use of land or building(s): 5,-MC-(LQ, L42-*)e- Valuation of proposed construction: 9 9122 o­0 r--) Is approval of Homeowner's Association or other private entity required? If yes,please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material, addition of 5% or more to the original impervious area or the removal of any trees? ❑NO. Applicant certifies that no change in site grade, impervious area or fill material will be used on this project.. ❑YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. [3-NO. Applicant certifies that no trees will be removed for this project. El YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,Fl, 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 - Fax: (904)247-5845 - hftp://www.ci.atlantic-beaciLfLus In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. I. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures, temporary and permanent, including setbacks, building height, number of stories and square footage. Identify any existing structures and uses. 3. If required by the Department of Public Works,a pre-construction topographical survey. 4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 5. Impervious Surface area calculations. Include driveways,sidewalks,patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Provide drainage plans. 7. Provide erosion and sediment control plan. 8. Any other documents requested by Building Dept.,Planning Dept,Public Works and Public Utilities. Address and contact information of person .a ;ve all correspondence regarding this application(please print). Name: /• .-rr bgr7-6-rr _ — Mailing Address: �� �f r_1 v Telephone: g -,.?hob 3 l a Yl -5 26-1 Fax: q/ - 6 ,Sq E-Mail: I hereby certify that I have read and examined this application and attached documentation and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the� ove informatio being true and correct and that the plans and supporting data have been or shall be provided as required. C 1 X Signature of Owner: �1N� Date: (Vo AS TO OWNER: ` wv`o�+n C, 1�js•r� r/• \ Sworn to and subscribed before me this l9 - day of Jar.w+�.a^ �,20OG State of Florida,County of Duval JEANNE M.SHAW Notary's Signature: MY COMMISSION#DD 435M �= E)(PIRES:May 31,2009 ten,,,,",yu ❑ Pers ally known induced identification Type of identification produced V:-L -�T�� «^" Siy►ature of Contractor.^ AS TO CONTRACTOR: Sworn to and subscribed before me this 5)1 day of � _,20__6 � State of Florida,County of Duval ( 1 � i SHiRLEY L.GRAHAM Notary's Signature: •- t Notary Public-State of Florida " !My Commission Expires Feb 14,2010 personally known Commission#DD 518533 Bonded By National Notary Mien. ❑ Produced identification Type of identification produced 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 Fax: (904)247-5845 • http://www.ci.atiantic-beacb.fLus Page 3 Revised 8/04 Date: May 23,2006 To: City of Atlantic Beach From: Elite Homes Subject: Transfer of Permit Please transfer the permit for Bryan&Leah Barker at 620 Beach Ave. from Dean Davis Builders to Elite Homes, Inc. r Thank u, Bryan ah Barker 1J`1 j CITY OF ATLANTIC BEACH PLAN REVIEW SHEET Routed to: z S.Makowski Building Department Public Works&Public Utilities Departments L. Higgins 800 Seminole Road 1200 Sandpiper Lane S. Doerr Atlantic Beach,Florida 32233 Atlantic Beach,Florida 32233 R. Carper (904)247-5800 (904)247-5834 D. Kaluzniak (904)247-5845 Fax (904)247-5843 Fax Public Safety PLAN REVIEW COMMENTS Permit Application# 0 6 31 q-r� Property Address: 6 ZO 4?6y- Applicant: Project: This permit application has been: E-1 Approved as noted by the Department. Final application approval must come from the Building Department. Sa'� Reviewed and the following items need attention: 0 to -- 6 -G A6 70 da' SU r :zoo G o/Pi` G� 2 WAv M Please re-submit your application when these items have been completed. Reviewed By: Date: 7 Xc Date Contractor Notified: HP Officejet 7410 Log for Personal Printer/Fax/Copier/Scanner Information Systems 904-247-5845 Jul 26 2006 9:29AM Last Transaction Date Time Type Identification Duration Pages Result Jul 26 9:29AM Fax Sent 92416184 0:26 1 OK CITY OF ATLANTIC BEACH �( �� Dce�•. "°"�\ PERMIT CALCULATION SHEET Date 7 �� r Address ....,.'hone 1 6' per sgft=$ w. )er sq ft=$ ,r sq ft— u_ rsgft= $ a $ w COl,_ ZOr FLOC......, IMPE -,, rACT FEE $ WERMVACTFEES $ 9/0, SEWER TAP FEES $ / ' ST CONSTRUCTION SURCHARGE $ STATE RADON SURCHARGE ; $ WATER CONNECT/METER ONLY $ A11A__ WATER CONNECT/TAP& METER $ A) WATER CROSS CONNECTION $ Af 1A WATER IMPACT FEE $ OTHER $ GRAND TOTAL DUE: $ 1/13103 WATER IMPACT FEE WORKSHEET DRAINAGE FIXTURE UNIT FIXTURE TYPE VALUE AS LOAD FIXTURES UNITS Automatic clothes washers,commercial 3 Automatic Clothes washers, residential 2 Bathroom group consisting of water closet, lavatory, Bidet, and bathtub or shower 6 Bathtub(with or without overhead shower or whirlpool attachments) 2 Bidet 2 Combination sink and tr 2 Dental lavatory1 Dishwashing machine,domestic 2 Drinking fountain/lcemaker 'r4 n Floor drains 2 . �[.. Hose bib 1 Kitchen sink,domestic 2 / Kitchen sink, domestic with food waste grinder and/or dishwasher 2 Laundry tray 1 or 2 co artrr mts 2 l �— Lavatory1 0� Shower com artnwn domestic 2 cl/ Sink 2 Urinal 4 Urinal, 1 gallon per flush or less ' , 2 < Wash sink circular or multiple)each set of faucets 2 Water closet,flushometer tank,public or private 4 Water closet,private installation 4 Water closet,pubfic installation 6 TOTAL NUMBER OF UMTS-- J MULTIPLIED 20 TOTAL$ 4 CITY OF ATLANTIC BEACH PUBLIC UTILITIES DEPARTMENT 1200 Sandpiper Lane Atlantic Beach,Florida 32233 -J � (904)247-5834 (904)247-5843 Fax www.coab.us PLAN REVIEW COMMENTS Permit Application # Property Address: 1l o?DSR Applicant: Project: AA,A �aaLl& k6 / " Your application is approved as noted by the Public Utilities Department. Final application approval must come from the Building Department. ❑ Your permit application has been reviewed by the Public Utilities Department and the following items need attention: 77 4-0 © P A h-e Please submit these requirements to the Public Utilities Department, 1200 Sandpiper Lane, Atlantic Beach, FL 32233 in order that we can approve your application. If you have any questions,please call (904) 247-5834. Revie d by Donna ak, Public Utilities Director Date ignature Contractor Notified Date Ild ri"'�f!�� CITY OF ATLANTIC BEACH BUILDING PERMIT APPLICATION- . (New/Residential & Commercial) V r _. .:_.. Date: • , Y _ r t Job Address: U�'�' 3 E A CtA Ar L/ A-TY"i;-i t_ 16.7{c.-fi 9 Owner's Name: ' ,ice`%f L&11tH ►"4 21��'�2 .Address: 1225 S&V4 M(tyR.,rrA con- f;--rr,•3-. n c. 3C-A cJ-1 Phone: CkY �yljj_03 Legal Description: Block Number: Lot Number: Zoning District: Contractor: De A P1 �-7 ��'` � State License Number: C Address: ��1 C c� Phone: Z' ? -ZZ'Z-Z City: .'!�l� � � State: * Zip:3 Z ZS v Fax: C,' c_71 Describe proposed use and work to be done:NQ-vl Present use of land or building(s): 5' 'Cf LQ, ��- Valuation of proposed construction: 'x'7(7 f J r> Is approval of Homeowner's Association or other private entity required? If yes,please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material, addi'ion of 5% or more to the original impervious area or the removal of any trees? ❑NO. Applicant certifies that no change in site grade, impervious area or fill material will be used on this project.. ❑YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. 2�•NO. Applicant certifies that no trees will be removed for this project. ❑YES. Removal of Trees will be required for this project. TREE REMOVAL PERMTT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Verily zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. 800 Seminole Road •Atlantic Beach,Florida 32233-5445 In addition to construction and engineering detail, plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures, temporary and permanent, including setbacks, building height, number of stories and square footage. Identify any existing structures and uses. 3. If required by the Department of Public Works,a pre-construction topographical survey. 4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 5. Impervious Surface area calculations. Include driveways,sidewalks,patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Provide drainage plans. 7. Provide erosion and sediment control plan. 8. Any other documents requested by Building Dept.,Planning•Dept.,Public Works and Public Utilities. Address and contact information of person to receive all correspondence regarding this application(please print). Name: Mailing Address: /�CC'.� ✓l.J 3 ,S;� �1 ,�1x- %Sc�'�„ �''�° Telephone: "137-111:2-7 — - Fax: Z`� 7''�0�� E-Mail: I hereby certify that I have read and examined this application and attached documentation and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules, regulations, ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true and correct and that the plans and supporting data have been or shall be provided as required. /r t Signature of Owner. �v✓ QOM. Date: ` d 44p V AS TO OWNER: Swom to and subscribed before me this � � day of Ja*,..,. _ >200G State of Florida,County of Duval YAP JEANNE M.SHAW Notary's Signature: r� MY COMMISSION#DD 435986 �•. EXPIRES:May 31,2009 ❑ Pers nally known Rfi Bonded Thru Notary Public underwriters [0-11foduced identification Type of identification produced / Signature of Contractor: ,_- -- --� Date: f� t AS TO CONTRACTOR: � 1r Sworn to and subscribed before me this day of ✓ r!( � >2006'. State of Florida,County of Duval �l�Y'> DONNA L BUSSEY ��,-'�� 4,_= = MY COMMISSION#DD 412624 Notary's Signature: J' A• $` EXPIRES:March 30,2009 BondetlThruNef4ryPtANbUnderv+Mere [v]�Personally known ❑ Produced identification Type of identification produced 800 Seminole Road •Atlantic Beach, Florida 32233-5445 Phone: (904)247-5800 Fax: (904)247-5845 • http://www.ei.atiantic-beach.fl.us MAP E L (D 7 t LEGAL DES LOT 3. REPLA -c�_�t H,t>aL PIOE S¢y Nof.a- aT' 11�' PLAT BOOK 9 SVRWYv a=:....•, X7.4' z)MEW 3))Rtl EJ rroac- tJ MAY a 7m fS ;a)Y,Lite ?' N if)lit S7 a f ...f t M3' ?7+ tff 16 IVB S LEGEND- J- OES Dam fi R-JFftOTES P..L7IL5 aem;erEPM IRC atL so 75' Q ,y-�aarrs es_u a a' 1, uL-JiliaTrS 5°.G'f R2 j (J • -i:k•WIOE.. `U LP.-piJ10fi'7.91_ T sk LKs�oeE P?_M-0 ,!:S FFF.&wl Po.-02511127rS PM-!5) FGE 2"/•Zw:Iit ,I d"0 --- '• `moo zr 9'�,Rw orF£ 'P L-eif.7rrS fttm,-, NO I.D. - PC-S&ZAS P9:7-o C�),SZ.JZ' N P.IXMTEIS -JFf77TE>PNfI-9 u R E V f SI 0 KS PARTY CNIEF: MGS professional Surceya:s gb Ltappers 1 h Ylba4 0. DESCRIPTION DATE COMPUTED BY.' REH a.6 beCef. the sera: Rohan d�fneefs the wfiariufn ORASNJ BLt MSC R. E. for(h by the Fiottda. F. B: N/A PG: N/A Yappers in Amar i a j Code ur e'll IV :he faiemf Em,:•7en:y 1!ar,+famm :,gaa.y,Find Sveanee Rat-lap.Gnsa'Dr Ls Aaida,Ostadlr Associates, Inc. fib- aflf a� -b� 120075 Paul=,Cates_4/17/89,,k*a-tw Coe pzur:yshow crd ds abed • 'X" OJ DE TH 00 FLOOD-PLAJL4 sae. . 7sol 417oN ei�T16 v .w,r-•synnl rnrey...lies rat bee:peadal a crreaf LTie oazcn or ssbset of nMlers Nw-1¢a 6e lillr fa laalamovLuq n.6da 92211 :�.•1ory a!In•s•�h i��l prcye+ly. 1t is pcs-ale lb.,Opera oa 4-M:or fe:crd amended deed; re•!•+:�mis,ar • R04R the ho-d rim N, slr�neo;s+Y ec�;s offecl :arr_ (904) 9U59o9fi Ft.Y (eoS) ao�.sa9'1 y„-a:t�afii w.J:.zt emtasse2 a=Ch rrr}4�i _+n�. FL F;EC:S� MAP SHOWING BOUNDARY SURVEY OF LOTS 1 AND 2, DANIEL AND HACKETT REPEAT OF BLOCK 16, ATLANTIC BEACH, AS RECORDED IN PLAT BOOK 9, PAGE 35 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTIFIED TO: erg; BRYAN C. AND LEAH D. BARKER AMSOUTH BANK t d; STEWART TITLE INSURANCE BUSCHMAN, AHERN, PERSONS k BANKSTON r: r " LOT 4 BLOCK 16 yf, _ x S 89'53'31' E 106.00' (PLAT) FM 3/4-wDN PIPE S 89'52'52' E 105.95' (MEASURED) FOUND 3/4-IRON PIPE u NO IDENTIFICATIONU'7 NO IDENIIFICATWN 5.1.00' S.OD 0.0' 1Y.7• X STOIIACE b � AIR CONDITION 0 PAD ]a.0' .I �. COVERED N W d' I �Ky F art •:, W LLJ �h m ve' LOT 3 w N L a I BLOCK 16 Z y ONE STORY . Q" W 3 MASONRY I 3 U w k NO POSTED oQ IO oO Qo p o r = t Z z3.e' ❑ N ATI CONDITION I • - PAD f q� TIS LOT 1 I LOT 2 BLOCK 16 BLOCK 16 FOUND 1/2"IRON PIPE FOU D/t'X1DN APE No IOENnACATON N 89'S3'31N W 105.95' (MEASURED) No roENnDCA WN N 89'53'31" W 106.00' (PLAT) SIXTH STREET r (50.0'RIGHT OF WAY) NO I ACCEPTED BY: / LEGEND: R RADIUS —X—X- FENCE L LENGTH O CONCRETE NCTES. . A_SSU_MED N 000000 E REVISIONS I.BEARINGS ARE BASED ON THE BEARING OF ---ALONG THE y WESTERLY BOUNDARY LINE OF SUBJECT PARCEL. DAZE DESCRIPTION 2.BY GRAPHIC PLOTTING ONLY THE CAPTIONED LANDS LIE WITHIN FLOOD ZONE X AS SHOwN ON THE NATIONAL FLOOD INSURANCE MAP DATED APRIL 17,1989,COMMUNITY NUMBER 120075,PANEL 3. THIS SURVEY REFLECTS ALL EASEMENTS h RIGHTS OF WAY AS PER RECORDED PLAT h OR TITLE COMMITMENT :. IF SUPPLIED.UNLESS OTHERWISE STATED,NO OTHER TITLE VERIFICATION HAS BEEN PERFORMED BY THE UNDERSIGNED J y { THIS SURVEY NOT VALID WITHOUT THE EMBOSSED SEAL OF THE CERTIFYING SURVEYOR. JOB # 19463 DATE OF FIELD SURVEY: 12-20-02 ISSUE DATE:12-20-02 SC.AL.E: 1" 20' rl.:. y CERTIFICATE 2522 DOM S""' HEREBY CERTIFY n115 SURVEY WAS MADE UNDER MY RESPORMU CHAROE JOekSonville FIDFide 32204 AND MEETS THE MINIMUM TECHNKAL STANDARDS AS SET FORTH BY THE FLORIDA p..- (Phone)904-389-5989 BOARD OF P OFESSIONAL SURtc1CX5 AND MAPPENS W CHAPTER 81017-8,FLORIDA f/', (F-). 904-389-6175 E,PlMSUANi TO SECTION 472.072,FIMIRWA STATUIES.14M - J �5 MICHAEL J.AI LICENSED BUSINESS/8702 REGISTERED SURVEYOR AND MAP /4879 STATE OF FLORIDA LAND SURVEYS O CONSTRUCTION SURVEYS O SUBDIVISIONS ft, k,. L si- W. � Z f Y fi a w F / , Y CITY OF ATLANTIC BEACH cc: S� BUILDING/ZONING DEPARTMENT L.D. J 800 Seminole Road S"Doerr Atlantic Beach,Florida 32233 Wilt (904)247-5800 (904)247-5845 Fax www.coab.us PLAN REVIEW COMMENTS �,� � � � g _ 2 90 3 Permit Application # Property Address: Applicant: Project: ff 9 60 11/7 rn This permit application has been: 0 Approved Reviewed and the following items need attention: to z0v /~ G F 6C, R 3/o s�/r, cw PcAris wl-1boz15 R S 5' Ga�v r 2S A0 //0 D l a;.r uS' o IJ 2 AID 69Q '02� ' L ,,. O CoLzelkz wi )9&,Y Uv/r�iJt7+� •� Pc r Z) /(-Z, ro C,0 ar l z. wrr1�J G-o�-b �o L 77c j- #" 4,Y /oc, l3 6.14 DeAkb o PPLG' wq tL lq�1t 611 q6�T a P&45e 5 ,J 4C. G-F/ a,,,7 e&M 1/--/ .6 95 w cm,..r 'ior 0/-," G61Gt,YLr 9 , - 1 ease re-submit your app cation when these i ems ave been completed. 06/&�o Reviewed By: Date: A bzo,6 �1�4 Date Contractor Notified: �.. .. ���',�� ��' vile.' /�l L G�1,�/G,YY�G I��`�,?J�.-.�r�-c'r F Legal Lescription: IdlocK Number: Lot Number: Lotting Uis7trtct: Contractor: Q,CLiTF # ,d1 State License Number: :/ �]j Address: //0 //r71l4 r E S Phone:3&9-0�F0 3 - o .6'2// City:_ - Be State:�" Zip: Fax: �/ — /S I Describe proposed use and work to be done:OQ4W Present use of land or building(s): Valuation of proposed construction: Is approval of Homeowner's Association or other private entity required?_If yes,please submit with this application. Will phis project involve changes in elevation,site grade or any use of fill material,addition of 5%or more to the original impervious area or the removal of any trees? ❑NO. Applicant certifies that no change in site grade, impervious area or fill material will be used on this project. ❑YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. 29-NO. Applicant certifies that no trees will be removed for this project. ❑YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED, Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits,please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information,please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation,please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required.(If not required,written verification must be provided with this application.) The Department of Public Works is located at:1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Phone! (904)247-5RnO • Far (904)247-5R45 httn://www.ci.atlantic-beach.fl.us Mailing Address: /I //_ /r v r --t Telephone: _3 401'X6 3/ a Y/ -52 S/ Fax: -�ql- sq_E-Mail: 1 hereby certify that I have read and examined this application and attached documentation and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with,whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the a0ove inform atio being true and correct and that the plans and supporting data have been or shall be provided as required. Signature of Owner: Z� A­ _ •- Date: LO v% AS TO OWNER: Ttrygn, Sworn to and subscribed before me this � _ day of Joy 2000 State of Florida,County of Duval ��J ��j'► JEANNEM.SNotary's Signature: Uj(��" CJ ✓ i MY COMMISSION HAW 6 DD 435988 EXPIRES:May 31,2009 At,hi Boded mruNoanauwcuMewriers ❑❑� Perce�s nallyknown I LL-Irroduced identification 1 _ �/ Type of identification produced Signature of Contractor: L�✓l,� Date: AS TO CONTRACTOR: Sworn to and subscribed before me this py day of A6 -2o 20 6 State of Florida,County of Duval 71 „a , SHIRLEY L.GRAHAM 11 ,•, Notary's Signature: f M1 klh Notary Public-State of Florida y Commission Expires Feb 14,2010 'gM- Commission#DD 518533 E ersonally known Bonded By National Notary Asan. Produced identification Type of identification produced 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 Fax: (904)247-5845 - http://www.ei.atlantic-beach.fl.us Payr 7 Revised R/04 CITY OF ATLANTIC BEACH Cc- BUILDING/ZONING DEPARTMENT FOS J � 800 Seminole Road Atlantic Beach,Florida 32233 W (904)247-5800 (904)247-5845 Fax www.coab.us PLAN REVIEW COMMENTS Permit Application # d G - .519 ,5--1 Property Address: 14 a, , Applicant: Li > A M ES Project: Nil) Ji i?A/E 1&mdy Ami rd Oixi.5r This permit a plication has been: A ved D,F ��f o(t „moi r4uorl� Reviewed and the following items need attention: Of A Please re-submit you application n these items have been completed. Reviewed By: ti Date: Date Contractor Notified: �� 9 ' �/ HP OfficeJet 7410 Log for Personal Printer/Fax/Copier/Scanner Information Systems 904-247-5845 Jun 26 2006 11:30AM Last Transaction Date Time Type Identification Duration Pages Result Jun 26 11:30AM Fax Sent 92416184 0:29 1 OK HP OfficeJet 7410 Log for Personal Printer/Fax/Copier/Scanner Information Systems 904-247-5845 Jun 07 2006 8:57AM Last Transaction Date Time Type Identification Duration Pages Result Jun 7 8:57AM Fax Sent 92416184 0:24 1 OK HP Officejet 7410 Log for Personal Printer/Fax/Copier/Scanner Information Systems 904-247-5845 Jun 07 2006 8:56AM Last Transaction Date Time Type Identification Duration Pages Result Jun 7 8:56AM Fax Sent 92416184 0:30 1 OK iJ%J''�' CITY OF ATLANTIC BEACH '•, � j BUILDING PERMIT APPLICATION = �> (New/Residential & Commercial) `-JR X Date: b Job Address: U 2.V &A CA *WE � ATW-,+-)T7 C- Owner's Name:_I PY N-J g A R K v2-- —, Address: IZ2S Sfiyat mrtg rrA cig- 4-r-,o+w"c- 001- c44 Phone: CiDy J-yrt J.)-v3 Legal Description: Block Number: Lot Number: Zoning District: - Contractor: L i%/C #6.m o,-- 7 State License Number:- 96-ef doo tl � Address:_ Q/D /I T'4 4 V1 S Phone:.3` 9 .3 C 1 SLS� City:_ - L f�Ch State: Zip: Fax:_ ,�A 4V/ Describe proposed use and work to be done:0et-,lS�'. -1 rr f, -���.,.�.��(„o. o_c:,�.t z..�f- ,Mt J Present use of land or building(s): 5-1,4 C(LQ, .• �1, � c}- C ,n ltL Valuation of proposed construction:�9122 Is approval of Homeowner's Association or other private entity required? If yes,please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material, addition of 5% or more to the original impervious area or the removal of any trees? NO. Applicant certifies that no change in site grade, impervious area or fill material will be used on this project.. ❑YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. 25.No. Applicant certifies that no trees will be removed for this project. ❑YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 - Fax: (904)247-5845 - http://www.ci.adantic-beach.fLus In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures, temporary and permanent, including setbacks, building height, number of stories and square footage. Identify any existing structures and uses. 3. If required by the Department of Public Works,a pre-construction topographical survey. 4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 5. Impervious Surface area calculations. Include driveways,sidewalks,patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Provide drainage plans. 7. Provide erosion and sediment control plan. 8. Any other documents requested by Building Dept.,Planning Dept.,Public Works and Public Utilities. Address and contact information of person`^--;,,e all correspondence regarding this application(please print). a Name: L r,r,f - it�?Er"r�?1?'� Mailing Address: �91 Q Ty �_ _ — Telephone: _3 I r��0 3 R rf l -52 5" Fax: yl loo q- E-Mail: — I hereby certify that I have read and examined this application and attached documentation and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. 1 understand that the issuance of this permit is contingent upon 2theq�[ ove informatio being true and correct and that the plans and supporting data have been or shall be provided as required. x Signature of Owner: �v+i� ��� Date: Q l� AS TO OWNER: jrnq„ C,"1�jexrkat-r \ Sworn to and subscribed before me this / day of �.Jc. a,, ,200 State of Florida,County of Duval t9 fi JEANNE M.SHAW Notary's Signature: ..---- ,,; W COMMISs*N I DD 435986 EXPIRES:May 31,2009 • , e W*dr" WPUbkUW-, ❑ Personally known oduced identification t Type of identification producedl.��C 1�J 1 rte C- Signature of Contractor:_ �✓t�-� '..sa_�..� Date: /2� AS TO CONTRACTOR: Sworn to and subscribed before me this day of41 Li _,206 State of Florida,County of Duval SHIRLEY L.GRAHAM Notary's Signature: Notary Public-State of Florida .•1W Commission Expires Feb 14,2010 Commission#DD 518533 EZ/Personally(mown '' ,° ;;° '� - ❑ Bonded By Nara{Notary Asan. Produced identification Type of identification produced 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 Fax: (904)247-5845 . http://www.ci.atiantic-beack.fl.us Page 3 Revised 8104 Date: May 23,2006 To: City of Atlantic Beach From: Elite Homes Subject: Transfer of Permit Please transfer the permit for Bryan&Leah Barker at 620 Beach Ave. from Dean Davis Builders to Elite Homes,Inc. Thank y u, r Bryan eah Barker r'§a, CITY OF ATLANTIC BEACH C BUILDING /ZONING DEPARTMENT ' J 800 Seminole Road L Dloerr s Atlantic Beach,Florida 32233 Jail>� (904)247-5800 (904)247-5845 Fax www.coab.us PLAN REVIEW COMMENTS Permit Application # - .3195-9 Property Address: !p Z?,gAC// x V� Applicant: Z-L •Ts AX4 mE.5 .5-. 2-G, 0 Project: III&IC-tr If This permit application has been: ❑ Approved Reviewed and the following items need attention: C0J9AM"'Q1T-( 2 r--- N z eP ` o rL o - b - a Please re-submit yo application when hese items have been completed. Reviewed By: Date: 2 •O�o Date Contractor Notified: BP255UO2 CITY OF ATLANTIC BEACH 4/19/06 Application Tracking Action Log Maintenance 11 : 34 : 48 Application number . . . . . 06 00031959 Address . . . . . . . . . . . 620 BEACH AVE Application type . . . . . . SINGLE FAMILY RESIDENCE Revision number . . . . . . . Path/step/seq . . . . . . . . A 01 00 Agency . . . . . . . . . . . PLANNING Type information, press Enter. Action date . . . . . . . . 41906 Action by (F4 ) . . . . . . SD Action code (F4) . . . . . AP Time spent (hours) . . . . . 00 Correction report item . . N Y=Yes, N=No 1=Add new comment 2=Change comment 4=Delete comment Opt Seq Comments Print 1 . 00 Approved per Variance (ZVAR-2006-01) granted 04-18-06. Y _ 2 . 00 — 00 — Bottom F3=Exit F4=Prompt F9=Add std comment F12=Cancel F21=User defaults HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 3 June 16, 2006 Re: PERMIT for Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH AND TO MAKE MINOR PLAN CHANGES REQUESTED BY THE OWNER. Item No. 1 Set is revised and reissued. PRODUCT APPROVAL SPECIFICATION SHEET As required by Florida Statute 50JW and Florida Administrative Code 9B-72,please provide the information and approval numbers on the building components listed below,N they will be utilized on the construction project for wbich you are applying for a building permit. We recommend you contact you local product'supplier sbould you not know the product approval number for any of the applicable listed products.Information regarding State Product Approval may be obtained at www.floridabuitding.org CATEGORY/SUB. MANUFACTURM PRODUCT DESC. L DWATION OF USE FIA ORSJCR# CATEGORY 1.EXTERIOR DOORS ASSEMBLIES: A.ROLL-UP 4 PFJ D � t m Q 15.1 C, a �j W M- B.SECJ10NAL art�fe t+�ul'1GQtl1� C.SLIDING D.SWINGING OA44Zt711C 4 m 10bi ie LC1e(J) Pe[ WWye Pressu +-70170 E.AUTOMATIC 2.WINDOWS A_AWNING B.CASEMENT C.DUAL ACTION D.DOUBLE HUNG � fc. � 2�D C' �'e �t�u (pb •t tQ.. t��t�lde � _ o �e 73 t E.SINGLE HUNG F.FIXED G.HORIZONTAL SLIDER H.PROJECTED I.PASS THROUGH CATEGORY I SUB- MANUFACTURER PRODUCT DESC. LAW fATION OF USE FIN OR SICRN CATEGORY J.MULLIONS K.WIND BREAKER I PANEL WALLS A.SIDING ('►..cbr- fLbRO B.SOFFITS C.EMS(EXTERIOR INSULATION FINISH SYSTEMS) D.STORE FRONTS E.CURTAIN WALLS F.WALL LOUVER G.GLASS BLOCK 4.ROOFING PRODUCTS A.BUILT UP ROOFING B.MODIFIED BITUMEN ROOF SYSTEM C.SINGLE PLY ROOF SYSTEMS D.SPRAY APPLIED POLYURETHANE ROOF SYSTEM E.ROOFING FASTENERS F.ROOFING INSULATION G.ASPHALT A % fly i2m i RL 25b.6 SHINGLES �.tti +�q�K. (j�IMW Q We NoA CATEGORY 1 SUR- MANUFACTURER PRODUCT DESC. LIMITATION OF USE FtA OR SJCR# CATEGORY 7.STRUCTURAL COMPONENTS A.TRUSS PLATES B.WOOD CONNECTORS C.ANCHORS D.EXTERIOR COOLERS-FREEZERS E.INSULATION FORM SYSTEMS F.ENGINEERED LUMBER G.WALL COMPONENTS H.DECK-ROOF &NEW&INNOVATIVE BUILDING ENVELOPE PRODUCTS A. B. The products listed below did not demonstrate product approval at plan review.I understand that at the time of inspection of these products,the following information must be available to the inspector on the jobsite;1)copy of the product approval,2)the performance characteristics which the product was approved,3)the performance characteristics which the product was tested and certified to comply with,4)copy of the applicable manufacturers installation requirements. Further,I understand these products may have to be removed if approval cannot be demonstrated daring inspection. ONTRACTORIAGENTIAPPLICANT SIGrNATURE DATE HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 RESPONSE TO COMMENTS PERMIT No. 06-31959 Building Comments: 1. Comment: Change plans to 2004 F.B.C. AiffV) To ` '¢^' °"J Sr beS/6A� 4*A6 Response: Sheet T-1 indicates Florida Residential Code 2004 2.oi( Comment: All Bedroom windows must meet egress, F.B.C. R310, show on plans Response: F.B.C. 8310 states "...every sleeping room shall have at least one operable emergency escape and rescue opening." Identification of egress windows added to sheets A-2, A-3 and A-4 and issued by Addendum No. 1 3. Comment: Product appro�vasfoPr windows, doors, garage d�000rs,�ro�i�g,g✓v exterior envelope. N A7 Response: Data will be provided by Contractor. 4.04 Comment: Show connectors for roof hold downs on 2nd floor porch Sheet S-5 Response: Connector designation added and sheet reissued by Addendum No. 1. General call-out of all connectors shown on Sheet S-4 as Roof Holddown Requirements 5. Comment: Show on plans how the Icynene foam in the atic is going to comply with R 314.2.3 a HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 Response: 318" gwb is added by notes and on appropriate sections, reissued by Addendum No. 1. GAN ^107- ,� IT VA-W PCS--r Sg'L7?o�6 u�ou�D B6r 7'/� a".•1T2d A�7"fi�, 6. Comment: Show grade of lumber for all structural lumber. Response: Addendum No. 1 adds notes indicating lumber grades, see Sheets A-9 and A-13. TA Comment:. Window Schedule is blank, supply design pressures for each window. Response: Window schedule is completed and issued by addendum No. 1. 8.0K. Comment: Give details of deck and stair railings to comply with R 312.1 and R 312.2 Response: Notes requiring compliance with code sections added to drawings. Railing systems will be manufactured units complying with code and as selected by Owner, see sheet A-9. 9.04 Comment: Give nail patterns for all structural sheeting to meet wind loads Response: Fastening Schedule from F.B.C. added to drawings and issued by Addendum No. 1, see Sheet S-5. I O.or Comment: Show collar ties @ 48" o.c. sheet A-13. Give details if cripple wall shown on same page. Response: Collars added and cripple wall deleted by Addendum No. 1 11. Comment: Elect. All outlets in bedrooms must be arc fault. Response: Indication of arc fault outlets added at all appropriate locations on issued by Addendum No. 1, see Sheets E-1, E-2, E-3. HARLESTON PARKES.) R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 12. Comment: Please show GFI outlets in bath, kitchen, garage and outside. s#ow oN Pct Response: Indication of GFI outlets added at all appropriate locations on issued by Addendum No. 1, see Sheets E-1, E-2, E-3. 130K,Comment: Show connection of ledger, page A-9 and A-11. Response: Notes added and sheets reissued by Addendum No. 1. 14 Q4omment: Provide Mechanical Drawings. Response: Schematic Mechanical layout added to plans and reissued by Addendum No. 1 End of Response pause PRODUCT APPROVAL SPECIFICATION SHEET As required by Florida Statute SWJM and Flrids Administratkve Code 98-72,please provide the information and approval numbers on the building componads lied below,if they will be utiiloed on the construction project fur wbieb you are appbring for a building permit. We recommend you contact you local prod a supplier should you not know the product approval number for any of the applicable listed produets.Iuformation regarding State Product Approval may be obtained at www.floridabnildina.ora C&IrEGMYISIiB- MAMIMACTUMM YRODi M1013C. i°ATitt�IOFUSB �i1flRSJ( 1.KXTItIOR DOORS ASSEMBLIES: A.ROLL-tJ1' � k�% 'fy "�R �J.I B.SISCJIONAL M1�Q[OC hf+t/!'i�:Qt1G C.SLIDING D.SWINCANG �j � i 4 M Obi le Wfel P rIe Pressure +-Ibl 70 E.AUTOMATIC 2.VAN DOWS A_AWNING B.CASEMENT C.DUAL ACTION D.DOUBLE HUNG Z i DI4�s I'C ��u��' R��j '' E.SINGLE HUNG F.FIXED G.HORIZONTAL SLIDER R PROJECTED u L PASS THROUGH f i CATEGORY!SU$- MANUFAGTiJM PRODUCT DFSC LIMiTA11�T OFU88 FL#OB.SiCB# CATEGORY L MULLIONS K.WIND BREAKER 3.PANEL WALLS A.SIDING cocbr B.SOFFITS C.EIFS(EXI ERIOR INSULATION FINISH SYSTEMS) D.STORE FRONTS E.CURTAIN WALLS F.WALL LOUVER G.GLASS BLOCK 4.$OOFING PRODUCTS A.BUILT UP ROOFING B.MODIFIED BITUMEN ROOF SYSTEM C.SINGLE PLY ROOF SYSTEMS D.SPRAY APPLIED POLYURETHANE ROOF SYSTEM E.ROOFING FASTENERS F.ROOFING INSULATION G.ASPHALT ILftW*M AS too' � R f1�t�' �Ctt11 i ,b SHINGLES 4 CATEGORYISM MAMWAGTIIREB PRODUGTDBSC LUOUTIONOFUSE FiJEOASJCgt# CATEGORY 7.STRUCTURAL COMPONENTS A.TRUSS PLATES &WOOD CONNECTORS C.ANCHORS D.EXTERIOR COOLERS-FREEZERS E.INSULATION FORM SYSTEMS F ENGWEERM LUMBER G.WALL COIAPONENTS H.DECK-ROOF 8.NEW&INNOVATTVE BUHMING ENVELOPE PRODUCTS A. B_ The product listed below did not demonstrate product approval at plan redew.I understand that at the time of iospeetioa of them product,the following information must be available to the inspector an the jobsit;1)copy of the product apprsoval,2)the performance characteristics which the product was approved,3)the performance characterhAw which the product was tested and certified to comply with,d)copy of the applicable manufacturers installation requirements. Further,I understand then products may Lave to be removed V approval cannot be demonstrated daring Inspection. ,6 Des ONTRACTOR/AGENT/APPLICANT SIGNATL)RE DATE HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 3 June 16, 2006 Re: PERMIT for Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH AND TO MAKE MINOR PLAN CHANGES REQUESTED BY THE OWNER. Item No. 1 Set is revised and reissued. HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 RESPONSE TO COMMENTS PERMIT No. 06-31959 Building Comments: 1. Comment: Change plans to 2004 F.B.C. Response: Sheet T-1 indicates Florida Residential Code 2004 2. Comment: All Bedroom windows must meet egress, F.B.C. R310, show on plans Response: F.B.C. R310 states "...every sleeping room shall have at least one operable emergency escape and rescue opening." Identification of egress windows added to sheets A-2, A-3 and A-4 and issued by Addendum No. 1 3. Comment: Product approval for windows, doors, garage doors, roofing, exterior envelope. Response: Data will be provided by Contractor. 4. Comment: Show connectors for roof hold downs on 2"d floor porch Sheet S-5 Response: Connector designation added and sheet reissued by Addendum No. 1. General call-out of all connectors shown on Sheet S-4 as Roof Holddown Requirements 5. Comment: Show on plans how the Icynene foam in the atic is going to comply with R 314.2.3 HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 Response: 3/8" gwb is added by notes and on appropriate sections, reissued by Addendum No. 1. 6. Comment: Show grade of lumber for all structural lumber. Response: Addendum No. 1 adds notes indicating lumber grades, see Sheets A-9 and A-13. 7. Comment: Window Schedule is blank, supply design pressures for each window. Response: Window schedule is completed and issued by addendum No. 1. 8. Comment: Give details of deck and stair railings to comply with R 312.1 and R 312.2 Response: Notes requiring compliance with code sections added to drawings. Railing systems will be manufactured units complying with code and as selected by Owner, see sheet A-9. 9. Comment: Give nail patterns for all structural sheeting to meet wind loads Response: Fastening Schedule from F.B.C. added to drawings and issued by Addendum No. 1, see Sheet S-5. 10. Comment: Show collar ties @ 48" o.c. sheet A-13. Give details if cripple wall shown on same page. Response: Collars added and cripple wall deleted by Addendum No. 1 11. Comment: Elect. All outlets in bedrooms must be arc fault. Response: Indication of arc fault outlets added at all appropriate locations on issued by Addendum No. 1, see Sheets E-1, E-2, E-3. HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 12. Comment: Please show GFI outlets in bath, kitchen, garage and outside. Response: Indication of GFI outlets added at all appropriate locations on issued by Addendum No. 1, see Sheets E-1, E-2, E-3. 13. Comment: Show connection of ledger, page A-9 and A-11. Response: Notes added and sheets reissued by Addendum No. 1. 14. Comment: Provide Mechanical Drawings, Response: Schematic Mechanical layout added to plans and reissued by Addendum No. 1 End of Response CITY OF ATLANTIC BEACH PUBLIC UTILITIES DEPARTMENT 1200 Sandpiper Lane Atlantic Beach,Florida 32233 (904)247-5834 (904)247-5843 Fax www.coab.us PLAN REVIEW COMMENTS Permit Application # 4 9.61 Property Address: df A h�✓ Applicant: Lim �D rh E Project: n /f, / *6 Your application is approved as noted by the Public Utilities Department. Final application approval must come from the Building Department. ❑ Your permit application has been reviewed by the Public Utilities Department and the following items need attention: Ew62 AI&E -X7S i G . //off o Please submit these requirements to the Public Utilities Department, 1200 Sandpiper Lane, Atlantic Beach, FL 32233 in order that we can approve your application. If you have any questions, please call (904) 247-5834. Revi9w,qd by Donna K ak, Public Utilities Director Date />-O(P ignature Contractor Notified Date CA W1, I CITY OF ATLANTIC BEACH BUILDING PERMIT APPLICATION (New I Residential & Commercial) Date: b Job Address: G ZD 3 EA C-A 4✓t AT YI-I-)Tl C.. 13 c.if -'t Owner's Name: {ZY r A�Kf=✓�— <Address: 122.5 SfLytr ffi nyt,PrA cl# Aar o wy1 c 3C�tc+J Phone: 90LI a--Yri J.LV3 Legal Description: Block Number. Lot Number: Zoning District: Contractor: i% /�o State License Number: � . Address:_ 1 D � 4 r- s Phone%3 0 - -,U' 3_ " c�4/ -15-2-5-1 City:_ - �� Ch State: Zip: Fax: IS Describe proposed use and work to be done:09-k-J Siv�y�� 1PA1-1A:::;? •� Q- r-� �N`�-� Present use of land or building(s): Valuation of proposed construction: If 5,?00 >0 Is approval of Homeowner's Association or other private entity required? If yes,please submit with this application. Will this project involve changes in elevation,site grade or any use of fill material, addition of 5% or more to the original impervious area or the removal of any trees? ❑NO. Applicant certifies that no change in site grade, impervious area or fill material will be used on this project.. ❑YES.' See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. �O. Applicant certifies that no trees will be removed for this project. ❑YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 - Fax: (904)247-5845 • http://www.ci.adantic-beaciLfLas In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures, temporary and permanent, including setbacks, building height, number of stories and square footage. Identify any existing structures and uses. 3. If required by the Department of Public Works,a pre-construction topographical survey. 4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 5. Impervious Surface area calculations. Include driveways,sidewalks,patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Provide drainage plans. 7. Provide erosion and sediment control pian. 8. Any other documents requested by Building Dept.,Planning Dept.,Public Works and Public Utilities. Address and contact information of person ---;,,e all correspondence regarding this application(please print). t i Name: — Mailing Address. ✓ l' _ Telephone: Fax: �y/ - _6 (t1 7 E-Mail: I hereby certify that 1 have read and examined this application and attached documentation and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon 2the . oveinformatio being true and correct and that the plans and supporting data have been or shall be provided as required. Signature of Owner. $vV\ Date: ( A Q AS TO OWNER: Trv��Xft C. t–/ \ Sworn to and subscribed before me this t9�� day of J a�,rw�.n _,20OG State of Florida,County of Duval JEANNE M.SHAW Notary's Signature: ...--- lYv t. MY COMMISSION#DD 4356 EXPIRES:May 31,M WvJedMu NOW Un*we n �❑ Personally known I a-Produced identification Type of identification produced Signature of Contractor._ �" ".r Date: /20 47k AS TO CONTRACTOR: f Sworn to and subscribed before me this day of-- � !A ,,20_6 State of Florida,County of Duval SHIRLEY L.GRAHAM Notary's Signature: �. _ ""-.---•---� Notary Public-State of Florida • Y Commission Expires Feb 14,2010 personally known Produced identification Commission#DD 518533 ❑ Bonded By National Notary Assn. Type of identification produced 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 • Fax: (904)247-5845 • http://www.ci.atlantic-beach.fLas Page 3 Revised 8104 Date: May 23, 2006 To: City of Atlantic Beach From: Elite Homes Subject: Transfer of Permit Please transfer the permit for Bryan&Leah Barker at 620 Beach Ave. from Dean Davis Builders o Elite Homes, Inc. i Thank u, g Bryan ah Barker i� a'r =i MAP E L o -r 4 l a LECAL DEQ c _1tt N cmc P_to6 53 S4� Hoi o Q L 0 T.I. REPLA _ PLR T 600K 9 i 3Jku=i 4) vir WE r n ncz- C 23.5'. ti ItAY G SQ• ooD3Y.E 4 9)C s is f t-8 /O.•3' oJ' 12� Tt4S St f � LEG�tD: n2ra{c OVOTEY x w^n5 v NO. G20 IRC LEII. tfM L a- -Z:6•VJ�DE_. �-�-Jili07cZ. :9GY RL9 m O ORitK S�Oe LP. - OVO�? r�7i I r'T * �7'• J • WALK M P?-At - JJtaTS PEFl—1 '! •O V P.0 P. --ZK <S REM Lm -- ^- K I�ri 1� ---FC. X.V27EES PAZIS} ff MAP SHOWING BOUNDARY SURVEY OF LOTS 1 AND 2, DANIEL AND HACKETT REPLAT OF BLOCK 16, ATLANTIC BEACH, AS RECORDED IN PLAT BOOK 9, PAGE 35 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTIFIED TO: BRYAN C. AND LEAH D. BARKER AMSOUTH BANK STEWART TITLE INSURANCE BUSCHMAN, AHERN, PERSONS & BANKSTON LOT 4 BLOCK 16 X S 89'53'31" E 1106.00' (PLAT) FOUND 3J4` IRON PIPE S $9'52'52" E 105.95' MEASURED FOUND 3 4• IRON PIPE NO IDENTIFICATION 0.2' NO IDENTIFICATION 53.00 53.00 zv.ti X I n STORAGE ry O ~ AIR CONDITIONER PAD o �D Q 24.0' 36.V - COVERED N w w a _3 N J 7 ¢ O tD .. • , a �.i O LTJ ; 4K d LOT 3 Z '8 I ; BLOCK 16 n ONE STORY LLI ,,, W MASONRY 1 '•" 0NO POSTED # e C e Ild Qy •a O 0 0 z ° ' •°' 0 V V1 Z 23.6' V) AIR Q ' CONDITIONER PAD N LOT 1 I LOT 2 N +' . BLOCK 16 ( BLOCK 16 s I e 53.00' 53.00• • ' FOUND ENTI IRON PIPE N 89'53'31" W 105.95' (MEASURED) FOUND ENTI IRON PIPE NO IDENTIFICATION NO IDENTIFICATION N 89'53'31" W 106.00' (PLAT) SIXTH STREET (50.0' RIGHT OF WAY) NOTES: I ACCEPTED 8Y: LEGEND: R - RADIUS --X--X= FENCE MAY-10-2006 WED 03:09 PM ATL, HCH, PUBLIC WORKS FAX NO, 904 247 5843 F. Ul ;: CITY OF ATLANTIC BEACH pU LIC WORKS I)E AR'I'MNT 1200 Sandpiper Lane V, / Atlantic 13e8cb-Flojida 32233 (904)247-5834 (904)241-5843 F" ww.vxoab.us PLAN RFVIEW COMMENTS Permit A pplicatiOn # � IVA Property Applicant: Project: a your application is approved as noted by the Public Works Department. pttaa, applica"ou approval must come from the Building DepartMeat. your permit application has beer. reviewed by the Public Works Department and the following items need attetiaon: COMMENTS 5/10/06 1) Erosion a:ld sediment controllan with agtall-s still re ui.re ; able-Encroa�cchm—ent ermit vers ease move cean Blvd, sidewalk ca out e-k!.3tincg concrete sa ewalk to remain ro driveway area . --_- f please submit these requirements to the Public Works Department, 1200 Sandpiper Lane, Atlantic Beach, PL 32233 in order that we can 'rpprove your application. if you have any questions, please call (904) 247-5834. Reviewed by Rick er, P.E.,Public Works Dilor ignature MU 0 $ Z�G Contractor Notified Date fc_�Xea�5- 0 HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 2 May 25, 2006 Re: PERMIT for Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE PUBLIC WORKS DEPARTMENT OF THE CITY OF ATLANTIC BEACH. Item No. 1 Sheet A-1 is revised and reissued to; Show Erosion and sediment control on Site Plan and to provide detail of sediment fence. Show concrete pavement at driveways from the property line to the edge of existing pavement in lieu of brick pavers on sand bed. Brick pavers at walks removed from city right-of-way. 2� � Y AGENDA COMMUNITY DEVELOPMENT BOARD CITY OF ATLANTIC BEACH Tuesday,April 18,2006 at 7:00 p.m. City Hall Commission Chambers,800 Seminole Road 1. Call to order and pledge of allegiance. 2. Approval of Minutes from the regular meeting of March 21,2006. 3. Recognition of Visitors. 4. Old Business. None. 5. New Business. a. Request from Gil Phillips to consider the Third Street side of a lot as the front of the lot y (corner lot) rather than the Sherry Drive side for property at 390 Third Street. / ZVAR-2006-01, Bryan and Leah Barker. Request for a Variance to allow a 1� nonconforming structure to be reconstructed in the existing footprint for property within the RS-2 Zoning District and located at 620 Beach Avenue. 1 ( c. Discussion of 35-foot height limitation language to be considered as a vote referenda amendment to the City Charter. d. Reconsideration of Community Development Board's recommendation related to proposed revisions to Section 24-189 of the Land Development Regulations related to the approval process for two-lot divisions of property. (At the request of Mayor Wolfson.) 6. Adjournment. All information related to these applications and full legal descriptions for the subject properties are available for review at the City of Atlantic Beach Community Development Department located at 800 Seminole Road,Atlantic Beach, Florida. Interested parties may attend the meeting indicated in this notice and state your opinions, or comments regarding the agenda items may be mailed to the address contained in this notice. If a person decides to appeal any decision made by the Community Development Board with respect to any matter considered at the meeting, he or she will need a record of the proceedings, and for such purpose, may need to ensure that a verbatim record of the proceedings is made, which record includes the testimony and evidence upon which the appeal is based. Notice to persons needing special accommodations and to all hearing impaired persons: In accordance with the Americans with Disabilities Act, persons needing special accommodation to participate in this proceeding should contact the City of Atlantic Beach (904) 247-5800, 800 Seminole Road, Atlantic Beach, Florida 32233 not later than 5 days prior to the date meeting. AGENDA ITEM 5.b. AOIL COMMUNITY DEVELOPMENT DEPARTMENT STAFF REPORT April 18, 2006 Public Hearing ZVAR-2006-01, Bryan and Leah Barker To: Community Development Board From: Planning, Zoning and Community Development Department Date: April 12, 2006 Subject: ZVAR-2006-01 Applicant: Bryan and Leah Barker 620 Beach Avenue Atlantic Beach, Florida 32233 Request: Request for a Variance to allow a nonconforming structure to be reconstructed in the existing footprint for property within the RS-2 Zoning District and located at 620 Beach Avenue. Existing Zoning: RS-2 Future Land Use: Residential, Low Density Surrounding Zoning: RS-2 STAFF COMMENTS The property owners have requested a Variance to allow a nonconforming structure to be reconstructed in the existing footprint for property within the RS-2 Zoning District and located at 620 Beach Avenue, as depicted on the attached Site Plan. With any motion to approve this request,the Community Development Board should also consider the following provision, finding other justification for approval rather than solely based upon the nonconforming characteristics of the existing structure. Sec. 24-85. Nonconforming Lots, Uses and Structures (a) Intent. Within the established Zoning Districts, there exist Lots, Structures and Uses of Land that were lawful prior to the adoption of these Land Development Regulations. Such Lots,Uses and Structures would be prohibited,restricted or regulated through the provisions of this Chapter or the adopted Comprehensive Plan. It is the intent of this Section to recognize the legal rights entitled to property owners of existing Nonconforming Lots,Uses and Structures,and to permit such non-conformities to continue in accordance with such rights,but not to otherwise encourage their continued survival. Furthermore,the presence of any nonconforming characteristic shall not be considered as justification for the granting of Variances and any Nonconforming Structure or Use, which is made conforming shall not be permitted to revert to any Nonconforming Structure or Use. (d) Grounds for approval of a Variance. A Variance may be granted, at the discretion of the Community Development Board,for the following reasons. 1. exceptional topographic conditions of or near the property. 2. surrounding conditions or circumstances impacting the property disparately from nearby properties. 3. exceptional circumstances preventing the reasonable use of the property as compared to other properties in the area. 4. onerous effect of regulations enacted after platting or after development of the property or after construction of improvements upon the property. 5. irregular shape of the property warranting special consideration. 6. substandard size of a Lot of Record warranting a Variance in order to provide for the reasonable Use of the property. SUGGESTED ACTION TO RECOMMEND APPROVAL The Community Development Board may consider a motion to approve this request for a Variance to allow a nonconforming structure to be reconstructed in the existing footprint for property within the RS-2 Zoning District and located at 620 Beach Avenue as depicted on the attached Site Plan, and provided: ❑ 1. There are exceptional topographic conditions of or near the property. ❑ 2. There are surrounding conditions or circumstances impacting the property disparately from nearby properties. 2 ❑ 3. There are exceptional circumstances preventing the reasonable use of the property as compared to other properties in the area. F-14. There are regulations,which were enacted after platting or after development of the property or after construction of improvements upon the property, that have onerous effect upon current use and development of the property. ❑ 5. The lots are of irregular shape of the property warranting special consideration. ❑ 6. The lots are of substandard size warranting a Variance in order to provide for the reasonable Use of the property. SUGGESTED ACTION TO RECOMMEND DENIAL The Community Development Board may consider a motion to deny this request for a Variance to allow a nonconforming structure to be reconstructed in the existing footprint for property within the RS-2 Zoning District and located at 620 Beach Avenue, Street, provided: ❑ 1. There are no exceptional topographic conditions of or near the property. ❑2. There are no surrounding conditions or circumstances impacting the property disparately from nearby properties. ❑ 3. There are no exceptional circumstances preventing the reasonable use of the property as compared to other properties in the area. ❑ 4. There are no regulations enacted after platting or after development of the property or after construction of improvements upon the property having an onerous effect upon existing use and development of the property. ❑ 5. The lots are not of irregular shape of the property warranting special consideration. ❑ 6. The lots are not of substandard size warranting a Variance in order to provide for the reasonable Use of the property. 3 P. 0 TRANSACTION REPORT �c MAY-110-2006 UED 03; 10 PM � K FOR: P:TL, BCH. PUBLIC WORKS 904 247 5843 ;K DATE START RECEIVER `(X TIME PAGES TYPE NOTE M� DP �c MAY-10 03:09 PM 02416513 47" 1 SEND OK 815 TOTAL 47S P GES: l M CITY OF ATLANTY-4 BEACH 4. ':'';` PYLIC WORKS IDEIt AR TMENT i ) ? 1200 Sandpiper Lane Atlantic Beaeb.Florida 32233 i (904)247-5834 (904)247-5843 Fax www.coab.u3 PLAN REVIEW COMMENTS Permit Appliution P f o!„�.�..,�,J_,.._ ._. Property Address: Applicant: -D�� I �jj.�-..�._. AfProject: --- �.1w'1- Q your application is approved as noted by the Public Works Department. Magi applicatiolm apl3l oval must come from the Haaddfimg gDepartmeSt. Your permit applicatioi1 has been reviewed by the public Works Department and the following item,i need attention: COMMENTS 5/10/06 T- 1) F,,:-o _. ... sion and sediment control 21-an with details stluii:_t�3; Revocab e Encroac�irnerit Permit re�ui or ave? in ritalo -wa easy: move Ocean Bivc . sidewalk existinq concrete sidewaj-7—�o-- I-nmzI n I r-r1�17ATOAV Aras��.+y ----- CITY OF ATLANTIC BEACH BUILDING PERMIT APPLICATION �r (New/ Residential & Commercial) Date: '\ Job Address: 3EAC-t4 A-tlE ANY-t-a,iT1c. �,EZjt..il - ":Owner's Name: ,,Address: 122.5 SEL VA- rV\AYL,rr+i gid= 60AcH Phone: 90U J-YJ44.-v3 Legal Description: Block Number: Lot Number: Zoning District: Contractor: 1 /e A t's � 7 r`'` � State License Number: C.3i✓Q`p(o b� C Address: lr ��� C�'- _ Phone: G � � City: ;iX State: {' Zip:3 Z%g 0 Fax: (.,''(-) J a Describe proposed use and work to be done:NQ_>_z ems.—Fe�,r.� s i ,� �-- k��`` t✓ -J Present use of land or building(s): 5­:4 Crr,t�,,, Valuation of proposed construction: [7� :J Is approval of Homeowner's Association or other private entity required? If yes,please submit with this application_ Will ,his project involve changes in elevation, site grade or any use of fill material, addition of 5% or more to the original impervious area or the removal of any trees? ❑NO. Applicant certifies that no change in site grade, impervious area or fill material will be used on this project., ❑YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. 2 -NO. Applicant certifies that no trees will be removed for this project. ❑YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP I. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 • Fax: (904)247-5845 • http://www.ei.atlantic-beach.1l.us HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 1 May 1, 2006 Re: PERMIT for Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE CITY OF ATLANTIC BEACH. Item No. 1 Sheet A-1 is revised to show drainage, storm water treatment locations and volumes. Treatment areas are shown for two properties, the single westerly lot, (53' on Sixth Street and 100' on Ocean Blvd.) and combined easterly lots (106' on Sixth Street and 100' on Beach Ave). Item No. 2 Building footprint on combined lot addressed by Variance approval by the Community Development Board at their April, 2006 meeting. Av<x5 �d 3), C OSa CITY OF ATLANTIC BEACH .:� PUBLIC WORKS DEPARTMENT 1200 Sandpiper Lane Atlantic Beach,Florida 32233 (904)247-5834 (904)247-5843 Fax www.coab.us ]PLAN REVR EW COMMlEN75 Permit Application N lv:�_/ 9.g Property Address: f,A( A L Applicant: I&V( -6 Project: ,S ❑ Your application is approved as noted by the Public Works Department. Final application approval must come from the Bunding Department. Your permit application has been reviewed by the Public Works Department and the following items need attention: Provide drainage plans./I,� Provide erosion and sediment control plan with details. Proposed impervious is less than existing impervious. Therefore, on-site retention (LDR 24-661bl ) not required. Treatment volume for 1/2" over entire site required (LDR 24-66{dl ) = 663 ft3. GAr-, ot-. Maximum driveway width limited to 24,-'Wer City Code 19-7 . If brick pavers to be used in City right-of-way to connect driveways to pavement,, a Revocable Encroachment Permit is required. Where Guest Cottage drive crosses City sidewalks, walk must be maintained as concrete. Cannot be replaced with pavers. (City Code 19-7) . Please submit these requirements to the Public Works Department, 1200 Sandpiper Lane, Atlantic Beach, FL 32233 in order that we can approve your application. If you have any questions, please call (904)247•,5834. iteview " Carper, P.F., Public Works Director F Date Signature Contractor Notified Date j (? iZ14 06 P. 01 TRANSACTION REPORT JAN-19-2006 THU 08.34 AM FOR: ATL. BCH. PUBLIC WORKS 904 247 5843 �c DATE START RECEIVER TX TIME PAGES TYPE NOTE M# DP JAN-19 08:33 AM 92476513 48" 1 SEND OK 142 TOTAL 48S PAGES: 1 CITY OF A'T'LANTIC BEACH :.i PU-BLIC Wow ADFPARTM NT 1200 Sandpiper Lane Atlantic Beach.Florida.32233 (904)247-5934 (904)247-5943 fax WWW,coab.us PLAN REVIEW (COMMF-NTS Permit A►ppti¢stion # ,.� .� . t Property Address: Applicant: Project: a Your application is approved as noted by the Public Works Department. Y,azH application appro,$al mast come from the Budding DeP2713308t. Your permit application has been reviewed by the Public 'Works Department and the following items need attention: Provide Provide erosion and sediment control plan with details . Proposed impervious is less than existing impervious. CITY OF ATLANTIC BEACH Cc: �5 BUILDING/ZONING DEPARTMENT 800 Seminole Road Airq, s Atlantic Beach,Florida 32233 (904)247-5800 (904)247-5845 Fax www.coab.us PLAN REVIEW COMMENTS 3 g _ 296 3 Permit Application # Q 3196` Property Address: ;7. Applicant: G L i f S Project: This permit application has been: ❑ Approved ® Reviewed and the following items need attention: C G to 2-oo v - —' PcArvs ® GL w%.✓L')o�s ' p ' , 51 s ow ory w i r ® r . g ffe o 7� z. Al' C-F1 a ar c am Tl—� Aq i T OU7 INA, Please re-submit your app ica ' n when these i ems nave been completed. Reviewed By: ''_ Date: A /7Z0.6 Date Contractor Notified: CITY OF ATLANTIC BEACH PLAN REVIEW SHEET to .Makowski -119r Building Department Public Works&Public Utilities Departments L. Higgins 800 Seminole Road 1200 Sandpiper Lane S. Doerr Atlantic Beach,Florida 32233 Atlantic Beach,Florida 32233 R. Carper (904)247-5800 (904)247-5834 (904)247-5845 Fax (904)247-5843 Fax D.blitKalSafety Public Safety PLAN REVIEW COMMENTS Permit Application# �' `� P}� I f` at_`j Property Address: { . Applicant: c L1 ' , ._ . Project: l' � L'� This permit application has been: EJ Approved as noted by the Department. Final application approval must come from the Building Department. Reviewed and the following items need attention: Alt?fD 7-0 CW -, TO 7,OOV G0I316K ri ,v L:OAPS 1Nr61&,V 4&,9,bS 77 wo V W� y Please re-submit your applipTtllon when these items have been completed. Reviewed By: Date: 4Z b� -W Date Contractor Notified: CITY OF ATLANTIC BEACH PLAN REVIEW SHEET r Routed to: S.Makowski 6T Jr Building Department Public Works&Public Utilities Departments L. Higgins 800 Seminole Road 1200 Sandpiper Lane S. Doerr Atlantic Beach,Florida 32233 Atlantic Beach,Florida 32233 R. Carper (904)247-5800 (904)247-5834 D. Kaluzniak (904)247-5845 Fax (904)247-5843 Fax Public Safety PLAN REVIEW COMMENTS Permit Application# D G —3/ 9s7 Property Address: 4�ZO lefo-�'-G// 4 t/Gf Applicant: Project: This permit application has been: Approved as noted by the Department. Final application approval must come from the Building Department. Reviewed and the followingitems need attention: tion: n67�j o �DO Nbf T/ Q !� Zoo V; sa 461 ll�lov wv T/ T / r, TGA/%-� S ff�Dt/ �S At T f - d- o0 7V Zoo V o � �� /a�✓ ��S rnnie7, AJ Please re-submit your apoication when these items have been completed. Reviewed By: Date: O Date Contractor Notified: 7 b� HARLESTON PARKES.) R.A. .ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 5 PERMIT No. 31959 July 13, 2006 Re: Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH. Item No. 1 Sheet S-5 is revised and reissued. W HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 4 PERMIT No. 31959 June 27, 2006 Re: Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH AND TO MAKE MINOR PLAN CHANGES REQUESTED BY THE OWNER. Item No. 1 Set is revised and reissued. x . 00 PRODUCT APPROVAL SPECIFICATION SHEET b u)� eodw, As required by Florida Statute 553.842 and Florida Administrative Code 9B72,please provide the information and approval numbers on the building components listed below,if they will be utilized on the construction project for which you are applying for a building permit.We recommend you contact you local product supplier should you not know the product approval number for any of the applicable listed products.Information regarding State Product Approval may be obtained at www.floridabuilding.org CATEGORY/SUB MANUFACTURER PRODUCT DESC LIMITATION OF USE Fife' CATEGORY• 1.EXTERIOR DOORS ASSEMBLIES: A.ROLL-UP Clopay Steel Pan(Min 24 ga.)Single car up to 9' Design Pressures:+42/48 PSF2 Design Wind Speed Max 145 FUN 4913.1 Garage Doors 0"wide.Windcode W7 MPH for use inside and outside the high velocity hurricane wind zone. B.SECTIONAL C.SLIDING D.SWINGING Pella Clad Hinged Glass Wind Zone 4,Missle Level D,Cycle Pressure+70/40 FUN 49696.1 E.AUTOMATIC 2.WINDOWS: A.AWNING B.CASEMENT C.DUAL ACTION D.DOUBLE HUNG Pella Proline Series Double Hung H-R50 FUN 6432,10 E.SINGLE HUNG F.FIXED G.HORIZONTAL SLIDER H.PROJECTED I.PASS THROUGH J.MULLIONS K WIND BREAKER 3.PANEL WALLS A.SIDING Fraser cedar Cedar Shakes,widths 4"to 14", Flre retardant and preservative treated,tapered or FUN 4854.1 Products Ltd length 24" non-tapered cedar shakes graded and certified to CSSB 1995 Standards B.SOFFITS C.EIFS(EXTERIOR INSULATION FINISH SYSTEMS) D.STORE FRONTS E.CURTAIN WALLS F.WALL LOUVER G.GLASS BLOCK 4.ROOFING PRODUCTS A.BUILT UP ROOFING B.MODIFIED BITUMEN ROOF SYSTEM C.SINGLE PLY ROOF SYSTEMS D.SPRAY APPLIED POLYURETHANE ROOF SYSTEM E.ROOFING FASTENERS F.ROOFING INSULATION G.ASPHALT Certain Teed Corp. Fiberglass Laminate Shingles Refer to current Miami-Dade Code NOA FL#250.6 SHINGLES Landmark AR30 H.WOOD SHINGLES ANDSHAKES 1.ROOFING SLATE J.ROOF TILE ADHESIVES K.CEMENTS- ADHESIVES- COATINGS L.LIQUID APPLIED ROOF SYSTEMS M. UNDERLAYMENTS N.NON-STRUCTURAL METAL ROOFING O.ROOFING TILES P.WATERPROOFING S.SHUTTERS A.ACCORDIAN B.BAHAMA C.STORM PANELS D.COLONIAL E.ROLL-UP F.EQUIPMENTS 6.SKYLIGHTS A.SKYLIGHT 7.STRUCTURAL COMPONENTS A.TRUSS PLATES B.WOOD CONNECTORS C.ANCHORS D.EXTERIOR COLLERS-FREEZERS E.INSULATION FORM SYSTEMS F.ENGINEERED LUMBER G.WALL COMPONENTS i H.DECK-ROOF S.NEW&INNOVATIVE BUILDING ENVELOPE PRODUCTS A. I-B- The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products,the followig information must be available to the inspector on the jobsite;1)copy of the product approval,2)the performance characteristics which the product was approved,3)the performance characteristics which the product was tested and certified to comply with,4)copy of the applicable manufacturers installation requirements. Further,I understand these products may haveto be removed if approval cannot be demousstrated during inspection. i CONTRACTOR/AGENT/APPLICANT SIGNATURE PRODUCT APPROVAL SPECIFICATION SHEET As required by Florida Statute 553.842 and Florida Administrative Code 9B72,please provide the information and approval numbers on the building components listed below,if they will be utilized on the construction project for which you are applying for a building permit.We recommend you contact you local product supplier should you not know the product approval number for any of the applicable listed products.Information regarding State Product Approval may be obtained at www.floridabuilding.org Ii. I.EXTERIOR DOORS ASSEMBLIES: A.ROLL-UP Clopay Steel Pan(Min 24 ga.)Single car up to 9' Design Pressures:+42/48 PSF2 Design Wind Speed Max 145 FIA 4913.1 Garage Doors 0"wide.Windcode W7 MPH for use inside and outside the high velocity hurricane wind zone. B.SECTIONAL C.SLIDING A SWINGING Pella Clad Hinged Glass Wind Zone 4,Missle Level D,Cycle Pressure+70/-70 FL#49696.1 E.AUTOMATIC 2.WINDOWS: A.AWNING B.CASEMENT C.DUAL ACTION D.DOUBLE HUNG Pella Proline Series Double Hung H-R50 FL#6432.10 E.SINGLE HUNG F.FIXED G.HORIZONTAL SLIDER H.PROJECTED 1.PASS THROUGH J.MULLIONS K.WIND BREAKER 3.PANEL WALLS A.SIDING Fraser cedar Cedar Shakes,widths 4"to 14", Fire retardant and preservative treated,tapered or FL#4854.1 Products Ltd. length 24" non-tapered cedar shakes graded and certified to CSSB 1995 Standards B.SOFFITS C.EIFS(EXTERIOR INSULATION FINISH SYSTEMS) D.STORE FRONTS E.CURTAIN WALLS F.WALL LOUVER G.GLASS BLOCK 4.ROOFING PRODUCTS A.BUILT UP ROOFING B.MODIFIED BITUMEN ROOF SYSTEM C.SINGLE PLY ROOF SYSTEMS D.SPRAY APPLIED POLYURETHANE ROOF SYSTEM E.ROOFING FASTENERS F.ROOFING INSULATION G.ASPHALT Certain Teed Corp. Fiberglass Laminate Shingles Refer to current Miami-Dade Code NOA FL#250.6 SHINGLES Landmark AR30 H.WOOD SHINGLES ANDSHAKES 1.ROOFING SLATE J.ROOF TILE ADHESIVES K.CEMENTS- ADHESIVES- COATINGS L.LIQUID APPLIED ROOF SYSTEMS M. UNDERLAYMENTS N.NON-STRUCTURAL METAL ROOFING O.ROOFING TILES P.WATERPROOFING S.SHUTTERS A.ACCORDIAN B.BAHAMA C.STORM PANELS D.COLONIAL E.ROLL-UP F.EQUIPMENTS 6.SKYLIGHTS A.SKYLIGHT 7.STRUCTURAL COMPONENTS A.TRUSS PLATES B.WOOD CONNECTORS C.ANCHORS D.EXTERIOR COLLERS-FREEZERS E.INSULATION FORM SYSTEMS F.ENGINEERED LUMBER G.WALL COMPONENTS H.DECK-ROOF &NEW&INNOVATIVE BUILDING ENVELOPE PRODUCTS A. B. The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products,the followig information most be available to the inspector on the jobsite;1)copy of the product approval,2)the performance characteristics which the product was approved,3)the performance characteristics which the product was tested and certified to comply with,4)copy of the applicable manufacturers installation requirements. Further,I understand these products may haveto be removed if approval cannot be demousstrated during inspection. i CONTRACTORIAGENT/APPLICANT SIGNATURE HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 4 PERMIT No. 31959 June 27, 2006 Re: Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH AND TO MAKE MINOR PLAN CHANGES REQUESTED BY THE OWNER. Item No. 1 Set is revised and reissued. 0� HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 5 PERMIT No. 31959 July 13, 2006 Re: Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH. Item No. 1 Sheet S-5 is revised and reissued. O PRODUCT APPROVAL SPECIFICATION SHEET 'bbW1( ow� As required by Florida Statute 553.842 and Florida Administrative Code 911172,please provide the information and approval numbers on the building components listed below,if they will be utilized on the construction project for which you are applying for a building permit.We recommend you contact you local product supplier should you not know the product approval number for any of the applicable listed products.Information regarding State Product Approval may be obtained at www.floridabuildiog.org CATEGORYISUR MANUFACTURER PRODUCTDESC. LIMMATIONOFUSE FLM CATEGORY 1.EXTERIOR DOORS ASSEMBLIES, A.ROLL UP Clopay Steel Pan(Min 24 ga)Single car up to 9' Design Pressures:+421-49 PSF2 Design Wind Speed Max 145 FLA 4913.1 Garage Doors 0"wide.Windcode W7 MPH for use inside nod outside the high velocity hurricane wind zone. B.SECTIONAL C.SLIDING D.SWINGING Pena Clad Hinged Glass Wind Zone 4,W ssle Level D,Cycle Pressure+70%70 FL#49696.1 E.AUTOMATIC 2.WINDOWS: A.AWNING B.CASEMENT C.DUAL ACTION D.DOUBLE HUNG Pella Proline Series Double Hung H-1150 FL#6432.10 E.SINGLE HUNG F.FIXED G.HORIZONTAL SLIDER H.PROJECTED 1.PASS THROUGH J.MULLIONS K.WIND BREAKER 3.PANEL WALLS A.SIDING Fraser cedar Cedar Shakes,widths 4"to 14", Fire retardant and preservative treated,tapered or FLA 4854.1 Products Ltd length 24" non-tapered cedar shakes graded and certified to CSSB 1995 Standards B.SOFFITS C.EIFS(EXTERIOR INSULATION FINISH SYSTEMS) D.STORE FRONTS E.CURTAIN WALLS F.WALL LOUVER G.GLASS BLOCK 4.ROOFING PRODUCTS A.BUILT UP ROOFING B.MODIFIED BITUMEN ROOF SYSTEM C.SINGLE PLY ROOF SYSTEMS D.SPRAY APPLIED POLYURETHANE ROOF SYSTEM E.ROOFING FASTENERS F.ROOFING INSULATION G.ASPHALT Certain Tad Corp. Fiberglass Laminato Shmgles Refer to amait Miami-Dade Code NOA FL#250.6 SHINGLES Landmark AR30 H.WOOD SHINGLES ANDSHAKES 1.ROOFING SLATE J.ROOF TILE ADHESIVES K.CEMENTS- ADHESIVES- COATINGS L.LIQUID APPLIED ROOF SYSTEMS M. UNDERLAYMENTS N.NON-STRUCTURAL METAL ROOFING O.ROOFING TILES P.WATERPROOFING 5.SHUTTERS A.ACCORDIAN B.BAHAMA C.STORM PANELS D.COLONIAL E.ROLL.UP F.EQUIPMENTS 6.SKYLIGHTS A.SKYLIGHT 7.STRUCTURAL COMPONENTS A.TRUSS PLATES B.WOOD CONNECTORS C.ANCHORS D.EXTERIOR COLLERS-FREEZERS E.INSULATION FORM SYSTEMS F.ENGINEERED LUMBER G.WALL COMPONENTS H.DECK-ROOF &NEW&INNOVATIVE BUILDING ENVELOPE PRODUCTS A. B. The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products,the followig information must be available to the inspector on the jobsite;1)copy of the product approval,2)tbe performance characteristics which the product was approved,3)the performance characteristics which the product was tested and certified to comply with,4)copy of the applicable manufacturers installation requirements. Further,I understand these products may haveto be removed N approval cannot be demousstrated during inspection. CONTRACTOR/AGENT/APPLICANT SIGNATURE HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 6 PERMIT No. 31959 July 26, 2006 Re: Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH. Item No. 1 Sheets T-1, S-5 are revised and reissued. 0 HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 6 PERMIT No. 31959 July 26, 2006 Re: Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH. Item No. 1 Sheets T-9, S-5 are revised and reissued. d� HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 6 PERMIT No. 31959 July 26, 2006 Re: Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH. Item No. 1 Sheets T-1, S-5 are revised and reissued. (o PRODUCT APPROVAL SPECIFICATION SHEET As required by Florida Statute 53.842 and oda Administrative Code 911-72,please provide the information and approval numbers on the building components listed below,if they will be utilized on the construction project for which you are appbm%for a building permit. We recommend you contact you local productsupplier should you not know the product approval number for any of the appNod de listed products.Information regarding State Product Approval may be obtained at www.floridabuildina.ora CATBGORYISM MAfiiWAG1[f M PRODUCTme LuarATiroN oF ima FiiJ SJCBd� CATEGMY 1.EXTERIOR LOOKS ASSir'AlST3:F.S: A.ROLL,-UP � DeskFkAWWb� � ck t J' a egnAadalk B. ONAL ti ► C.SLIDING D.SWINGING ad4ji `�CtZone 4 Mj�le Levet P g�. I TT��� e Prpsur se +-tel7o E.AUTOMATIC 2.VVINDOWS A.AVVNING B.CA5EMFNT C.DUAL ACTION D.DOUBLE HUNG 7ipnp � �S e 1 D&LfMt-C "e-gsu t'e k'07*5 4 E.SINGLE HUNG F.FDLED G.HORIZONTAL SLIDER `� J H.PROJECTED I.PASS THROUGH CATEGORY I SUB- MANWACrU9=- PRODUCT'DEStr. LIIYIITATWN OFE]SE RA OR SIM CATFJGMY J.MULLIONS K.WIND BREAKER 3.PANEL WALLS A.SIDING Cocbr B.SOFFITS C.EIFS(EXTERIOR INSULATION FINISH SYSTEMS) D.STORE FRONTS E.CURTAIN WALLS F.WALL LOUVER G.GLASS BLOCK 4.ROOFING PRODUCTS A.BUILT UP ROOFING B.MODIFIED BITUMEN ROOF SYSTEM C.SINGLE PLY ROOF SYSTEMS D.SPRAY APPLIED POLYURETHANE ROOF SYSTEM E.ROOFING FAST15NERS F.ROOFING INSULATION G.ASPHALT111i �(, j •b SHINGLES LN trif IC. Code WA • CAT$601tY1 Ms. MMWACTUR8 PRODUCT DESS d unAritx vg vie xAt)R sxae 7.COMPONENTSCATBCRY STRUCTUIL4L A.TRUSS PLATES B.WOOD CONNECTORS C.ANCHORS D.EXTERIOR COOLERS-FREEZERS E.INSULATION FORM SYSTEMS F.ENGINEERED LUMBER G.WALL COMPONENTS R DECK-ROOF $.NEW&INNOVATIVE BUILDING ENVELOPE PRODUCTS A. B. The products listed below did not dommustrate product approval at pian review.I andersta'd that at the time of iespeetma of these products,the failmdug information must be available to the inspector on the jobsite;1)copy of the product approval,2)the performance ebaracteristics which the product was approwed,3)the performance characteristics which the product was tested and certified to comply with,4)copy of the applicable manufacturers installation requirements. Furtber,I understand them products may have to be removed if approval cannot be demonstrated during inspection. NTRACTORIAGENT/APPLICANT SIGNATURE DATE HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 ADDENDUM No. 3 June 16, 2006 Re: PERMIT for Barker Residence 620 Beach Avenue THIS ADDENDUM IS ISSUED TO RESPOND TO COMMENTS FROM THE BUILDING DEPARTMENT OF THE CITY OF ATLANTIC BEACH AND TO MAKE MINOR PLAN CHANGES REQUESTED BY THE OWNER. Item No. 1 Set is revised and reissued. Z)� O� HARLESTON PARKES, R.A. ARCHITECT ATLANTIC BEACH, FLORIDA 904-962-6368 FAX 904-241-7377 RESPONSE TO COMMENTS PERMIT No. 06-31969 Building Comments: 1. Comment: Change plans to 2004 F.B.C. Response: Sheet T-1 indicates Florida Residential Code 2004 2. Comment: All Bedroom windows must meet egress, F.B.C. R310, show on plans Response: F.B.C. R310 states "...every sleeping room shall have at least one operable emergency escape and rescue opening." Identification of egress windows added to sheets A-2, A-3 and A-4 and issued by Addendum No. 1 3. Comment: Product approval for windows, doors, garage doors, roofing, exterior envelope. Response: Data will be provided by Contractor. 4. Comment: Show connectors for roof hold downs on 2"d floor porch Sheet S-5 Response: Connector designation added and sheet reissued by Addendum No. 1. General call-out of all connectors shown on Sheet S-4 as Roof Holddown Requirements 5. Comment: Show on plans how the Icynene foam in the atic is going to comply with R 314.2.3 HARLESTON PARKES.) R.A. ARCHITECT ATLANTIC BEACH,FLORIDA 904-962-6368 FAX 904-241-7377 Response: 318" gwb is added by notes and on appropriate sections, reissued by Addendum No. 1. 6. Comment: Show grade of lumber for all structural lumber. Response: Addendum No. 1 adds notes indicating lumber grades, see Sheets A-9 and A-13. 7. Comment: Window Schedule is blank, supply design pressures for each window. Response: Window schedule is completed and issued by addendum No. 1. 8. Comment: Give details of deck and stair railings and R 312.2 to comply with R 312.1 Response: Notes requiring compliance with code section drawings. Railing systems will be manufactured unit s added to and as selected by Owner, see sheet A-g. s comp, with cod •E-3 'Z-3 'L-3 slaayS aas 'L 'ON wnpuappy Aq panssl UO suogeool aleudoidde lie le pappe slallno llnel ore to uolleolpul :esuodsaU -ilnel we eq isnw swooapaq ul slelino IIV •10943 :lu9wwo0 'LL 6 "ON wnpuappy Aq palolep IleM oldduo PUB pappe sielloo :asuodsa�j abed awes uo annoys lleM aldduo l! si!elap anlE) '£6-y laays o o «gV 0 sag JeIIOo MoyS :luawwoo '0l g-S laayS aas '1, 'ON wnpuappy Aq panssl PUB s6ulMe�p of pappe •0.8.3 woo alnpayos 6ulualse3 :esuodsaN speol pulM laaw of 6ullaays leinionils lie jol suaalled Ilea anl� :luawwo l g 6-y laays aas 'jeumo Aq paloeles se pue epoo ql!m 6UTAldwoo shun painloeinuew eq IIIM swelsAs 6ullleN -s6ulMeip of pappe suolloes opoo ql!m aauelldwoo 6Uutnbei seloN :esuodseN Z•Z6c a pue 6•ZLC 11 yl!M Aldwoo of s6ulllej alels pue Noap}o sllelap aAlE) :luawwO0 .g G 'ON wnpuappe Aq panssl pue poleldwoo sl alnpayos MopulM :osuodse�j •MORUIM uoee .Iol sainssaid u61sop Alddns 'Nuelq sl alnpayos MopulM :luawwo:D L •E 4-y pue 6-y slaayS aas `sepea6 jagwnl 6ugeolpul solou sppe I, -ON wnpuappy :asuodseN -jagwnl leinlonils Ile aol jagwnl to 9pej6 MoyS :luawwoo •9 1, 'ON wnpuappy Aq pensslai 'suogoas oleudoidde uo pue selou Aq pappe sl qM6 „gds :asuodsaa LL£L-1VZ-b06 XV3 89£9-Z96-b06 vm0-13 `H3vaG aii mvuv J,DaIIHJ'dV ''V'2I `S3XHVd NOLS3rlHVH asuodsoa do pug penssiaa pue sueld o;pappe lnoAel leoluegoeW o,�euaay Swn asuodse pueppV q 's6uimej© leoiueyoaw ap}noad :}uewwoo -V 6 -ON wnpueppV Aq ponssiaa s}aaus pue pappe s91ON :esuodsea �_d pug&V 96ad `aa6pal jo uol;oeuuoo moult :juewwoo £� -t.3'Z-3 `�-3 slaayg aas `� 'ON wnpueppV Aq penssi O 0 I,,,�dojdd6 f ie pappe slelino IjJ Io uoil<eoipul :esuodseH u -apis;no ` Q UI S1911no 131D molts eseald 4uawwo9 Z� 054pDu3 i tl 1vo4-aclovJ 10+ a PERMIT RTMMNT APPLICATION i �5-ka� b4- Dow APPLIC �. ;n ne ,or C aft �SsU� v ' � � REQUIRED DEPT: .-l.� Gu G�-r-b(C P►SUP Y N PLANNING Property. 12eC 0`f N BUILDING P Y PUBLIC WORKS Applicant 17\1 0 Y N PUBLIC UTILITIES Y N FIRE DEPT. Project: f3 Y N PUBLIC SAFETY N APPROVAL Lu U REQUIRED AGENCY: RECEIVED BY: INITIAL: DATE: w Y N D.E.P HUFSTETLER ¢ � CY Y A S.J.R.W.M. CARPER Cr Lu z Y ARMY CORPS of ENG CARPER a Y Ing I HOTELS&RESAURANTS HUFSTETLER APPLICATION STATUS CIRCLE ONE: SITE BUILDING DA AP REVIEWED BY: INITIAL: DATE: ® 1 ST REV (�_ d C� /�v�h 5, 1�. wwl It /►1nn s h2 yq k. �. /2 JCLJ C Co JL PLANNING ® ® 2ND REV BUILDING PUBLIC WORKS PUBLIC UTILITIES FIRE DEPT. PUBLIC SAFETY ® ® 3RD REV Returu this form to the Bifild inp-Department once you have entered your comments into the AS400. Public Works Plan Review Comuments Date: 1a� y` IDI Initials: , Project Name/Address: hd�� 6W,�4 AUApplication/Permit#I d3 S f '1'�.f +i - Il { C'i S _ -� f lF .rv' f" ra ra il" �'1�' y _.{�I :1f F I[rx 5, IY�I �'f:[µri ti`j '?.r t {+P..• �,r+(*i tfiY i �Y 4..�3.'S,.c �(>•. ��11 1 -A�r:}'t' ru: Trn,?, cvP u} L f[ 3 cLL':r{zf I���3�',�k=[ . ^MP I's Lw- �wfifT..r." ._. Provide impervious surface calculations. ❑ Provide erosion and sediment control plans with installation details and maintenance schedule. Provide drainage plans'showing site topography(flow arrows, etc.) ❑ Provide construction site management plan, including Right-of- Tay Permit if using ❑ , right-of-way for construction parking. Provide a pre-construction topographic survey prepared by a Florida Licensed ❑ Professional Land Surveyor, showing 1' contours. Section 24-66(b) of the Land Development Regulations requires on-site storage for increased runoff. Provide Delta volume calculations and on-site retention required per Q Section 24-66(b). (See attached info. Sheet) If on-site storage is required, a post construction topographic survey documenting proper construction will be required. A Right-of-Way Permit must be obtained. ❑ A Revocable Encroachment Permit must be obtained for ❑ Pool—Wellpoint(if used)must discharge into vegetated area 10' minimum-from street ❑ or drainage feature (swale or structure) All driveway aprons must be concrete, 5 inches thick,4000 psi,with fiberruesh from the . edge of the pavement to the property line.Reinforcing rods or mesh are not allowed in ❑ the ROW(Commercial driveways—6"thick). Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction fromithe center of the cut. Repair must be shown on L the plans. ��!ftp S• c� CITY OF ATLANTIC BEACH CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WA�GU�NEE3 S�fl11ENTS 800 Seminole Road 904247-5800 Atlantic Beach,Florida 32233-5445 r ti Fax 904247-5845 Date 1107 �jj PER # Job Address dC' t-Y1 /�1l�Ni�, ISSUED BY THE CI Permitee: Telephone# 6(,2- 1 I Permittee Address: I ZZS !Se-1y&,,- ��S21�uo� Gr o /� {Q,c,,,{�� IAS I FL 3 zZ-33 _ Requesting Permission to Construct: Da iy-e U.,)±!c IA) CAj� tZ,4t-t ow�y 6 exc-Q,x d- Oc.Q" 6 I vp . Location: (Reference to Cross-Street) Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. A Letter of Notification was mailed to the following Utilities/Municipalities: 0f1 +„C4tu WaS CAZ IN Jacksonville Electric Authority Yes( ) No ( ) Date: Bell South Telephone Company Yes( ) No ( ) Date: Ferrell Gas Yes( ) No ( ) Date: Comcast Yes( ) No ( ) Date: 21 Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Gh21s t1+1A - 2r9CA) (Contractor's Project Superintendent)located at aO3t Bek . _ ,q..I.Qa,,,{,; &p FL Telephone#: 34i-090 4 All materials and equipment shall be subject to inspection by the Director of Public Works or his designee. 5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications and the manner satisfactory to the city. 6. A sketch of plans covering details of this installation, as well as, a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the city Riaht of Way are to be included with this application.- iN sN,+,J 7. This permittee shall commence actual construction in good faith with 1,0 days. If the beginning date is more than 60 days from date of permit approval, then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. 8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder, and the Holier will, at all times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. ' The Director of Public Works shall be noted twenty-four (24) hours prior to starting work and again immediately upon completion. FINER Date: 1 i I Z�I O7 me this 2 day of z— m the Cptxrty of Duval, roitcroymmission f Florida, personally appeared Ycl a.v\ (�civ f <e c ' PubNc at Large,State of Florida,couno expires: Oersonally Known: or Produced Identification: ✓ Fti 09r A�� �Nnt yal:�ir ,tate of Honda Helen P VVOson Nc a My Co+nmission DD579225 Of F�O� Expires 08/15/2010 R.O.W. Permit Attachment of for R.O.W.Permit# issued ,2005 Atlantic Beach,FL 32233 Owner's Name: +- 1A.4\ QAr14tr Property Address: Go-6 �ce^, /kue a—v— AV�A(, �e ., 1%L X333 Subdivision: 4, Lhcac.e.F KIP N k I Lot#/Block#: 1 +-Z- '61 vc.-IL 1� R.E. #: 1-7o to-"3- oc)c:�o REVOCABLE ENCROACHMENT PERMIT ^�,, THIS REVOCABLE ENCROACHMENT PERMIT, issued on this f� day of J , 2007, by Atlantic Beach, Florida, a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY" and of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above(copies attached). This work is generally described as: L'�2►ve►,W 2502e-IcAL t ©cam C31 v0 Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty (30)days notice by CITY to the USER, said notice to USER shall be given by certified mail, return receipt requested, to the following address: The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing,or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes,Land Development Code, and all other land use and code requirements of the CITY. The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The Page I of 2 USER shall, at the discretion of the CITY, be requested to submit as-built drawings showing the change within thirty(30)days after the day of completion. This permit shall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed /by the USER. DATED and SIGNED this > day of DQ 2007. CITY OF ATLANTIC BEACH,FLORIDA, By: a municipal corporation: Property Owner _ B : Jim son,City Manager Attest: c. Rick Carffer,Public Works Director TATE OF FLORIDA LINTY OF DUVAL On this --2-t AA,day of //o u aT t_6,_ , 200*personally appeared before me, a Notary Public in and for said County and State, _D tAtiax. Fle rida�, the property owner of _— ' ` 4ZO $EAch �y'E Atlantic Beach, Florimown to me to be the person(s) described in and who executed the foregoing instrument; who acknowledged to me that he or she executed the same freely and voluntarily and for the uses and purpo s therein mentioned. J-1, c a Suvee c«a By: Notary Public in for said County and State pe Owner (to be Vigned in presence of the Notary) �otvar P90 No�+��uu�iir S t2 of i poi „i Helen r r,iso MY Commission DD579225 OFF%°'p Expires 0,91 51?.�J10 Page 2 of 2