Loading...
Permit 880 Beach Avenue CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 04-00028037 Date 4/08/04 Property Address . . . . . . 880 BEACH AVE Tenant nbr, name . . . . . . WINDOW AND DOOR REPLCMENT Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 29666 Owner Contractor ------------------------ ------------------------ HINES, ROBERT ACE DOOR & WINDOW SERVICE 880 BEACH AVENUE 9123 HARE AVENUE ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32211 (904) 727-6811 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 180 . 00 Plan Check Fee 90 . 00 Issue Date . . . . Valuation . . . . 29666 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 180 . 00 180 . 00 . 00 . 00 Plan Check Total 90 . 00 90 . 00 . 00 . 00 Grand Total 270 . 00 270 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. , )-, ( - 1"k BUILDING OFFICIAL Cc: CITY OF ATLANTIC BEACH D. Ford BUILDING / ZONING DEPARTMENT _771 g-g i—ns 9-D-0-er- 800 Seminole Road Atlantic Beach,Florida 32233 (904)247-5800 (904)247-5845 Fax 'Cc) I PLAN REVIEW COMMENTS Permit Application # OL4 - 0(��013 �-) Property Address: 0 r2��C;tl Y:�\V�- - Applicant: &C,'�> DOOR� �- UJ I IQ DOVJ Project: VJ I t-J C)o-Y\J �- D-CUR- T This permit application has been: Approved Reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed By: Date: '4 CITY OF ATLANTIC BEACH PERMIT APPLICATION FOR REPLACEMENT OF WINDOWS, SKYLIGHTS AND GARAGE DOORS OF SINGLE-FAMILY OR TWO-FAMILY (DUPLEX) CONSTRUCTION Date: 0 Job Address:— ?90 J3 e-a ve- 141 Owner's Name: R o b?�iT e,5 Address: WO Z e ec-1, 4 V,0- Phone: d Y6 -c��k )4, Legal Description: Block Number: Lot Number: Zoning District: Contractor: Ace Dxv -an.6 wy1doc,.) State License Number: Ce(o Vef,�-? Address: 11;a f e 4v,<, Phone: OdY) '7,;� ?- &? City: -3-a X State:F(- Zip:.gd t Fax: Ydl 797 0-rl -F Describe proposed use and work to be done: Wly)(14LJ -and Q(00f- (-e- Pj -8CeMe41-t- Present use of land or building(s): C-5 J'cl-f 0 T�'q, Valuation of proposed construction: a � 664 Is approval of Homeowner's Association or other private entity required? 416 If yes, please submit with this application. Building Data: e e- L y (ft) Mean Roof Height -(ft) Building Width (ft) Building Length Roof Slope *Window Elevation from Grade.,�- 6, V7 (ft) Window Height A Window Width Y's,6 T (ft) Measurement from corner of building to window (ft) I r 5 op h 4 a N, IL N�1� 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 Fax: (904)247-5845 - http://www.ei.atiantic-beach.fl.us Page I Revised 1/27/03 Procedure: In order to expedite issuance of permits provide all information as appropriate Incomplete applications may result in delay in issuance of permit. In addition to the building data,the following information is required: 1. Manufacturer's Test Report 2. Installation Procedures 3. Window Description/Type— V i e*e Se.r4 e,"-r XA/\ ,e 4. Garage Door Reserimption4y,e > 5. Skylights ReseripfiengFype 6. Elevation View of Window Locations wi I hereby certify that all information Pro this application is correct. Signature of Ownen A Date: ------------- I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with,whether specified herein or not. The granting of a permit does not presurne to give authority to violate or cancel the provisions of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true and correct and that the plans and supporting data have been or shall be provided as required. 1� Signature of Contractor: Z*6 Date: & -3 Address and contact information of person to receive all correspondence regarding this application (please print). /I-a le - - I Name: cr 0-y- A - Dao� Yld w , rAko-) Mailing Address: I_S lklaf I!n 'T a X 3 3L(P.-) Telephone: ?0(/ Fax: 7�1_7- 6el 3 E-Mail: AS TO OWNER: Sworn to and subscribed before me this day of 20 State of Florida,County of Duval Notary's Signature: ZBrends J.SmMwAa _ my c4mnl"w 001 96"s EU/Personally known eoms June 06,2007 El Produced identification Type of identification produced AS TO CONTRACTOR: Sworn to and subscribed before me this Y_X day of 20 State of Florida,County of Duval s Signature: Wr Peorsonally known Pr duced identification Type of identification produced 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 - Fax: (904)247-5845 - http://www.ci.atlantic-beach.fl.us Page 2 Revised 1/27/03 5 W14. RETURN B.o-ok 11730 Page 1951 PHONE# ,1, Permit number Tax Folio number Doc# 20 4 :12JI917 ..; I JLQ710 Page: 1951 Filel ' 'e"O""� --- ---04MI2004 12:08:39 PM N0110E OF CONMENCEMENT JIM FULLER CLERK- CIRCUIT COURT STATE OF FWRWA DUVAL COUNTY COUNTYOFDUVAL RECORDING S 5.00 TRUST FUND S 1.00 ME UMERMEE)hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713,Florida Statutes,the follming informatim is provided in this Notice of Commencement k (�o ' Ve- T �3 Des'im o'"erty* Sl)�/- Favn, 05- 2. General description of improvernients: W rl 80LJ 3. Owner information: a. Name and Address: 6�O b e/f'T /A r)e I�Ctl 4,18- TSCt-1 33;�33 b. Interest in property- F -- �- e/c, c. Nam and address of fee simple titlebolder(offier than owner): 4. Contractoes name and address:A e L)06,(- A)1,4 d 0 QJ q 0�� /4 1/& T a?, Fc 1 b.Fax number 6 9 1 j Phone number 5. Surety information: a. Name and address: lv"*'1,4 b. Phone number. c.Fax number d.Amount of borick 6. Lmder's name and address- a. Phone number b.Fax number 7. Person within the State of Florida designed by owner upon whorn notices or other documents maybe served as provided by 713.12(lXa),Florida Statues. Name and Address: a.Phone number b.Fax number. 8. In addition to himselfterselt owner designates of -eive a copy of the Lienor's Notice as provided in to rer Section 713.12(l)(b),Florida Statirtes. 9. Expiration date of Notice of Commencemamr—MbEe)expiration date is one (1) year from the date of Recording unless a different rs, Signature of Owner /71�--.I t'Irz Sworn to and subscribed before me this day of 20 C Notary: Known personallyAD shown: commission expires: ..sv ou. BrWWO J.Smmw** r4' '% My CwmftWon DDI 9W5 6, d; ExpWn June 06,2007 FROM :ACE DOOR & WINDOW SDRVICE FAX No. :9042499474 02 2004 05:35PM PI DOOR & A EWINDOW SERVICE, INC "(Xff sucem whW8 on your satis&ction'- SINCE Date: '(D To. From: Fax No. ;9- Y? No. of pages including cover: 6 LA-) Q. ce S'S'j Nuilp Offlee-, Showroom Only, 9 123 Hot Ave Jadmaville,Florift M11 $03 N.3rd St JaCk$M-yj!Ie F*W:h. r)2 322St,, 'rej(9ft)727-6911 FaM(904)72?.6813 Tel(9K 249-�4�7 FROM �AEE DOOR & WINDOW SDRVICE FAX NO. :9042499474 Apr. 02 2004 05:35PM P2 FLORIDA BUILDING CODE9 2001 DESIGN PRESSURES FOR OPENINGS (VERSIONI.01)-- BURJ)M DATA - WNW vellociw(mph) 1120 ComPliny XY7.Inc. Impoftnue F&cW 1.00 Prepared By Employee upo6we Cabmi-v 0 STRUMItEs Cifew Name John Due Wdwnal Pressure CoeWx*M 0.18 INURNAMINAL,LLC Job Oftenphon Test Project Mean Rout HeW*(ft) 30 Buildng 1 BuWft WkIth(ft) 75 eu*"Length(It) 44 Rooffillope (X:12) 5 Job Numbiw 2SON WALL OPENINGS ' OPEW OPENING LOCATION OPFINM OPE ING CHIMENSIONS MAXIMUM POSITIVE MAXIMIUK NEGATIVE MARK DESCRIP'TION ZONE ELEv-00 WOOT"(ft) HENu4v(ft) PRESSURE(psft PRESSURE(uaf) i 4;lcserrent 5 3 36.3 -"A A ; 4 3 Icausement 5 3 3 36.3 -4" 5 5 3 34.9 -45.9 i Icacssment 5 L 5 6 3 343 46.9 4 3 5 3 36.3 49.4 4 16 4 4 35.2 -3&3 4 16 3 3 364 -39.4 -39.4 4 3 3 36.3 1 4 16 3 2 36.3 �39A 4 16 3 36.3 .39.4 5 Is 3 2 36-3 48.6 15 5 6 33.7 -4 M icacsoment 5 -1 16 5 33.7 113 3 39.3 A 4 1 16. 1 2 36.3 i 2-, 35A -45.7 3 35A -MA 5 =c-'emant, 3 311-4 i lco;s 5 _7 L4.3 T -e 3 45.4 -39 ,v 27 3 315.4 AR I 1A T AA 4 33.4 -36.4 Wkfth Of ECIP S&iP(0)in led 4.4 Hf Y1 e ' A.(d(e5c g,5�0 AT-/,4,"T 4-L -,Ic wall opsnings.)ft hines-)ft Copyright 2002,StrucuxeS(ntemational.11C 41M04 STORMBREAKER PLUS 8.00oo(G .00013(G) AND FLORIDA CUSTOMERS CASEMENT (RETROFIT) (A) 6.. (A) INSTALLATION PROCEDURE SHU SIR END SCREWS(0) terior Track TOP SCREW IN TIE BAR GUIDE(F E: FASTENER REQUIREMENT UNIT HEIGHT I #-FASTENERS LESS THAN 30' 1 NME 30-THRU SO- is darsot W�� C-) Exterior Tra SNUIBER L,—OZ��(E) 60.25'THRU BW =4 END SCREWS(D) 7RE 00 < C C�o F:= 'r Tra D-U >>----Exterior 'rock Top SCREW IN TIE BAR GUIDE(Fl-\ C) C= SNUISER fie END SCREWS(D) --CREW IN HINGE TRACK(B) —N EEO 6.0000 L—L.0000(G) NOTES: A: USE #10 X 2-1/2" FASTENER TO ANCHOR UPPER AND LOWER JAMBS TO SUBSTRUCTURE. 'Cj PLACE THE SCREW ON THE EXTERIOR PLANE OF THE FRAME. (3-1/2- X 3/16- TAPCON TYPE ANCHOR IN MASONRY CONSTRUCTION)C 0 8: USE #8 X 2-1/2' FASTENER IN HINGE TR KS TO ANCHOR HARDWARE TO OPENING AT THE HEAD AND SILL. LOCATE SCREW IN SECOND HOLE FROM THE END OF THE HINGE TRACK CLOSEST TO THE CENTER OF THE WINDOW. IMPACT SNUB13ER CHART C: REPLACE ONE OF THE CENTER SCREWS IN THE OPERATOR WITH A #8 X 2-1/2' FASTENER, UNIT HEIGHT I SNUBBERS ANCHORING THE OPERATOR TO THE SUBSTRUCTURE. #� LESS THAN 30- D-. PLACE X 2-1/2' FASTENER THROUGH HOLES IN EACH END OF THE 8* SNUBBER! 3(r TmBy 4W 2 — INDICATES THAT PRODUCTION IS TO FABRICATE THIS PARIICULAR HOLE (STORMBREAKER PLUS ONLY). THESE SCREWS WILL ANCHOR THE SNUBBER. THROUGH THE 48'7HRU 85* 3 — JAMS, TO THE SUBSTRUCTURE. THE NUMBER Or�SNIUBBERS IS REDUCED AS THE WINDOW HEIGHT DECREASES. (SEE IMPACT SNUBBER CHART) E: USE 110 X 2-1/2' FASTENER TO ANCHOR CENTER OF JAMBS TO SUBSTRUCTURE. LOCATE THE SCREWS ON THE EXTERIOR PLANE OF THE FRAME. (3-1/2- X 3/16- TAPCON TYPE ANCHOR IN DISCLOSURE STATEMENI MASONRY CONSTRUCTION) F: REPLACE SCR2W IN THE TOP HOLE OF EACH TIE BAR GUIDE WITH A #8 X 3- FASTENER, ANCHORING This document Is the property of Simontori Winclosrs which micins all proprietary and other 11117 1117 14AR UI - I inji jPF right.to it.subject..tt- This document 1.p—ldd to the -*I-t-the Wsawedl G: FIELD MULLED APPLICATIONS ONLY. SEE TWIN CASEMENT INSTRUCTIONS. INSTALLER WILL BE camdIt1w that it 1,not to be disclosed.reproduced h whole or In part, nor owed In REQUIRED TO FABRICATE ADDITIONAL HOLES TO COMPLY WITH THE TWIN CASEMENT INSTALLATION coapnotion with the design.manufacture or repair of goods far anyone other Lhan Simonton REQUIREMENTS. Windows without Its convent. This reetriation shall not limit lh.reciplet.riot.to utill.. Information contolmod 1. this do-ment which 1.property obtained fi—on.ther Rev ev File: fa Re-visions Revised b3r Date 's Re-visions Revised br. Date INOO,34 SIMONTON* Vendor Put Number: W I N D 0 W S Drawn bT. JDD Scale: FIT Date:09/10/02 - IT CASEMENT Title: StormBreaker Plus and Florida Installation Procehir, SCREMS DIDICATES THAT PRODUCTIM IS To FABRICATE 7141S PARTICIAAR RME STORMBREAKER PLUS AND RASEPLATE(F) FLORIDA CUSTOMERS &.0000(a DOW.(C) PRE—MULLED CASEMENT (LH/RH) RETROFIT ONLY INSTALLATION PROCEDURE - ----- _*(A) 'a) E: FASTENER REQUIREMENT # LESS 30" 110,25-T�W 80'1 Exterior Track Opposite side syfnmetrically opposite BER END (D) LH RH .--L� SC"= BER END SCREWS SCREW 94 END SCREWS 0 TRACK(a) HINGE TRACK is //-6-M-EW 11 &0000 &0000(G NOTES: SCREW IM SCREWS SCREW IN A. USE #10 X 2-1/2" FASTENER TO ANCHOR UPPER AND LOWER JAMBS TO SUBSTRUCTURE. ERATUR(C BASEPLATE(F) ERATOR PLACE THE SCREW ON THE EXTERIOR PLANE OF THE FRAME. (3-1/2- X 3/16- TAPCON TYPE ANCHOR IN.MASONRY CONSTRUCTION) 8: USE #8 X 2-1/2 FASTENER IN HINGE TRACKS TO ANCHOR HARDWARE TO OPENING AT THE nterior Track HEAD AND SILL LOCATE SCREW IN SECOND HOLE FROM THE END OF THE HINGE TRACK IMPACT SNUBBER CHART CLOSEST TO THE CENTER OF THE WINDOW. C: REPLACE ONE OF THE CENTER SCREWS IN THE OPERATOR WITH A #8 X 2-1/2" FASTENER, If swillem ANCHORING THE OPERATOR TO THE SUBSTRUCTURE- 1 M-L'=--i: 1 1 D: PLACE C5 X 2-1/2' FASTENER THROUGH HOLES IN EACH END OF THE 8" SNUBBERS 2 (STORM REAKER PLUS ONLY). THESE SCREWS WILL ANCHOR THE SNUBBER. THROUGH THE - 1 65- 1 3 JAMB. TO THE SUBSTRUCTURE. THE NUMBER OF SNUB13ERS IS REDUCED AS THE WINDOW HEIGHT DECREASES. (SEE IMPACT SNUBBER CHART) THIS STEP IS NOT REQUIRED WHERE SNUBBER IS ATTACHED TO THE MUWON. I-- USE #10 X 2-1/2" FASTENER TO ANCHOR CENTER OF JAMBS TO SUBSTRUCTURE. LOCATE THE SCREWS ON THE EXTERIOR PLANE OF THE FRAME. (3-1/2- X 3/16- TAPCON TYPE ANCHOR DISCLOSURE STATEMENT IN MASONRY CONSTRUCTION) This docurnant Is the property of Sknonton Windows which retains as proprietary and other F: USE #8 X 1-1/2- FASTENER (2-1/2- X 3/16- TAPCON TYPE IN MASONRY CONSTRUCTION) TO ANCHOR BASEPLATES TO HEAD AND SILL IN 2X CONSTRUCTIN. right.to Its subject matter. This da-ment Is provided to the reciplent on the G)Pfeswedl G: USE #10 X 2-1/2" FASTENER (4' X 3/16* TAPCON TYPE ANCHOR IN MASONRY CONSTRUCTION) candition that It is not to be disdoewd.reproduced In whole or In pwl.nor used in TO ANCHOR SILL AND HEAD TO SUBSTRUCTURE. LOCATE THE FASTENERS ON THE INTERIOR PLANE corpnction with the design,—facture or repair of goods far anyone other than SknorAm OF THE FRAME. Wind-w without Its consent. This restriction oholl not lkntt the recipients right.to utilize InfornrKition caritolned In thin docurnent which 1.propery obtained from another se— lFe-v- Rev Fue: fs Revisions Revised b3r Date i's Revisions Revised b3r Date IN0037 f Vendor Part Number: 06 SIMONTON* W I N D 0 W S Drawn by: JDD Scale: FIT pat, 09/10/02 Se es: RETROFIT CASEMENT/MULLED 71tle: STORMEIREAKER PLUS AND FLORIDA INSTALLATION PROCEDUREj 010 7Z A 8 co Z m - z LO N CL 0 4) 6 CD I 46 .2 Q V) o (L E R. E z 0 z W< tj LL 0-4 E :b .2 i C-3 E- z < Ld IL V) uj V)< 0 C:) C C� C� LLJ LLJ LLj 0 Cc C) LL- - < UJ>- E -i V) D 0: 0 z o>0 W f-- - U, Z Ck: 2 D (f) m V, C g z i� a. Ld < m Z9 u, .2,a m Z,=')L'u, o 0 0<Xcr V) Zwwo- LD z V)<x Z=) T 0 103 < 0 M� .0 L.Li Ci V)Z<a3z 2) 0 LIJ =1 V 0 0��(t)0 LJ-j �> Z LLJ M -J U z f2 04 V) _3-i LLJ 2 < < D 0 LLJ F- LL- 0:2 p-1 C.) 0 Ui Ld U- V)=V7 <LL- X LLJ Li 0 Lij x m 0 IL M z s A P� s c o a —01 u C:) < Cc o cc: FE LLI LL. 4 .2 0 2 0 ZE t') LLI uj ui r I-- z LL— —----- L.Li Pi n LL 0 -J U) < V) 2 LLJ LLJ Lu>- W V) Ln -F cn < w 00 ui Q� uj 10 M lom �2 < <Z) --- z o>2 IV.- Lf) u P- - P4--th ril Ld w -j - 0 < 0 U- of U- C) 00 CLLtl:.:, -I-- < M6 wow C) LL 0 fn 0 < zn LU z x LIJ 2 D:3 —————— Er) m 0 0 EE UJ F-- z 0 ZOIZ (L 0 < 0 D < < LL' F- C) 0 < 0 -J to w F- < Ld z z :3 3: — < < o -,a m ZK LLJI Z 0 a 0 d U3 LL-Lj z F- z § 0 < — 0< :J z Qf 0 uj V)<cl� 0 < U- r,) CD CL 7- LLJ z _j (0 D Z< D < ::) C:) 00�4(no ui < Z,( Z -)Z;2 =1 d LLJ 0 < 0-1 X P V) 0 IGL)l LuLj :z UI V)x(n D C (,0 Lij CY z W,-fit UO) Lj C14 0 LLJ U) < z LLJ CL 02 .1 :s M E- FE U) co rN (D CL n 0 Lf) —J U)< 0 FY LLJ Lj F— LLJ>- U- to C) 0 a: <D c)F w V)Wol z 03 mz:c 0 z a. 19 w Z9 w 12,0 0 V)bi z Z), f5 0 (.n CLI < 0 LLJ C):2 0 LLJ Z LLI LLJ Z>_QZO U) m m ::3_5 Lu 0 < cr D 0 LLJ M�-- < LL. 0 0-1 u U 0 LL1 La V)Q:�V):-Z <LL- LIJ LLJ 0 ui(If 0 tt E 6 s 9 C) LO z P� C'I 0 C) 0 < o E -- ; E c z , A 9 uj 0 z 0 E ui T- z D LLJ V) 0 CL CL- 0 0 u m Z: LLJ D Ld LLI cr 02 P <72 Lij>- V) V) -T U) 0 < < Li X w V) Cl:� Lj 04 6 w P5 0 00 < MEP 0�U) < �t� u < (nLuom U U- 0 m, z :5 Z Ld m z 0 0 T- R� o L) Wm 0 z 0 z A a: a- < LLJ c)0 w 110 04 0 -1 0 z 0 w F- 0 LL. Z C)< Lti z ::3 U) LLI < 0 < z 10 m z LL,6 0 0 0 Lu Z T)La 00 w Lj U z < 0< ox Z X - 0 w V)<(If . 0 C) cc) 0 F- n 0 CL = uwo .0 (C) U)Z<m z Z) 0 0 V)0 < Z j;)- z 04 < -i_jwo 0�3 T-F= C)b 0 W L'i V>x V) Z) LLI (0 0 z A P P R 0 V E D CITY OF ATLANT1C BEACH BUILDING OFFICE AAMA/NWWDA 101/l.S.2-97 APR 0 7 2004 TEST REPORT SUMMARY By: Rendered to: SIMONTON WINDOWS SERIES/MODEL: 08-08 TYPE: PVC Casement Window Title of T-est-- Results Rating C-R50 36 x 72 Overall Design Pressure 50 psf Operating Force N/A Air Infiltration 0.01 cfm/ft' at r Resistance 9.0 psf Structural Test Pressure Forced Entry Resistance Grade 10 Referencc should be made to Report No. 05-30072.02 dated 03/28/02 for complete test specimen description and data. For ARC]HTECTURAL TESTING, INC. Digitally signe I by Lyiui George Ey—nn George, Project Manager LG:tjp Arcliftectural Testing AAMA/NWWDA 101/l.S.2-97 TEST REPORT Rendered to: SIMONTON WINDOWS One Cochrane Avenue Pemisboro, West Virginia 26415-9403 Report No: 05-30072.02 Test Date: 05/17/00 Report Date: 03/28/02 Expiration Date: 05/17/04 Project Summary: Aichitectural Testing, Inc. (ATI) was contracted by Simonton Windows to witness performance testing on their Series/Model 08-08 Poly Vinyl Chloride (PVC) casement window. The sample tested successfully met the performance requirements for a C-R50 36 x 72 rating. Test Specification: The test specimen was evaluated in accordance with AAMA/NWWDA 101/l.S.2-97, Voluntary Specifications for Ahaninum, Vinyl (PVQ and Wood kFindo�vs and Glass Doors. Test Specimen Description: Seri�s/Model: 08-08 Typ : Poly Vinyl Chloride (PVC) Casement Window OverallSize: 3' 0" wide by 6' 0" high Sash Size: 2' 10-1/4" wide by 5' 10-1/4" high Glazing Details: The window was exterior glazed using 3/4" thick sealed insulating glass fabricated with two 3/32" anriealed sheets separated by a steel spacer system. The glass was set Zgainst 1/2" wide glazing tape and secured using snap-fit dual durometer vinyl glazing beads. 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.testati.com I 05-30072.02 Page 2 of 4 Test Specimen Description: (Continued) Wev thers tripping: Descrilptio Quantit Location 1,4" co-extruded 2 Rows Perimeter of sash flexible vinyl leaf 3 8" co-extruded I Row Perimeter of sash flexible vinyl hollow bulb Fraine Construction: The frame was assembled using mitered and welded comer Construction. Sast. Construction: The sash was assembled using mitered and welded comer construction. Har iware: ID escription Quantit Location 3-point lock I Locking Jamb P astic lock keepers 3 Locking stile, 12" from each end and center S eel snubber system 2 Hinge stile/jamb, 23-1/2" from each end inge system 2 Head and sill, one per end Roto-operator I Sill, 9" from hinge Jamb Dranage: E escriotion Quantit Location 3'16" diameter 2 Bottom rail, I" from each end Rei forcement: No reinforcement was utilized. Installation: The window unit was installed into a 2" x 10" wood buck constructed from treated #2 grade pine and secured through the nailing fin with 1-1/4" drywall screws spaced 4" o,c. and sealed with silicone caulking. One #8 x 2-1/2" long screw was fastened through ead lock bar housing to the test buck (three total). A 05-30072.02 Page'D of 4 Test ResItIts: The iesults are tabulated as follows: Paraaraph Title of Test - Test Method Results Allowed 2.1.2 Air Infiltration (See Note #1) 2 2 @ 1.57 psf(25 mph) 0.01 cfm/ft 0.3 cfin/ft max. Note #I.- The tested specimen meets the performance levels specified in AAM,41NWPVDA 10111S. 2-97for air infiltration. 2.1.3 Water Resistance per ASTM E 547 WTP = 2.86 psf No leakage No leakage 2.1.4.2 Uniform Load Structural per ASTM E 330 (Permanent set measurements were taken on the lock stile) (Loads were held for 10 seconds) @ 22.5 psf(positive) negligible 0.2 81" max. @ 22.5 psf(negative) 0.006" 0.281" max. Genaral Note: No end measurements were taken on the member measured. The mea,,urements stated above include displacement as well as bending. This statement applies to al' Uniform Load tests performed. 2.1.7 Welded Comer Test Meets as stated Meets as stated 2.1.8 Forced Entry Resistance per ASTM F 588-97 Type: B Grade: 10 Lock Manipulation Test No entry No entry Test B I thru B3 No entry No entry Lock Manipulation Test No entry No entry 2.2.5.6.1 Vertical Deflection Test @ 45 lbf 0.71" 2.2.5.6.2 Hardware Load Test @ 5.0 lb/ft2 No damage No damage 1 05-30072.02 Page 4 of 4 Test Res ilts: (Continued) P ara jgph Title of Test - Test Method Results Allowed Optional Performance 4.3 Water Resistance per ASTM E 547 WTP = 9.0 psf No leakage No leakage 4.4.2 Uniform Load Structural per ASTM E330 (Permanent set measurements were taken on the lock stile) (Loads were held for 10 seconds) @ 75.0 psf(positive) 0.043" 0.2 81" max. @ 75.0 psf(negative) 0.045" 0.281" max. Detailed Irawings, representative samples of the test specimen, and a copy of this report will be retained )y ATI for a period of four years. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the above referenced specification. This report does not constitute certification of this product, which mdy only be granted by the certification program administrator. For ARC ITECTURAL TESTING, INC: Digitally sign.,d by Lynn George Lynn George Steven M. Urich, P.E. Project Manager Senior Project Engineer LG:tjp 05-'30072.(2 DOCUMENT CONTROL ADDENDUM #05-30072.00 Current Issue Date: 03/28/02 Report rs o.: 05-30072.01 R,-quested by: Al Crum, Simonton Windows Purpose: AAMA/NWWDA 101/l.S.2-97 testing on Series/Model 08-08 poly vinyl chloride (PVC) casement window, Issued Date: 06/02/00 C)mments: Certification copy to John Smith at Associated Laboratories, Inc. Report is o.: 05-30072.02 R�quested by: Cindy Dotson, Simonton Windows Purpose: Revise Report No. 05-30072.01. Issued Date: 03/28/02 C)mments: Add Florida P.E. seal to report. Twelve original reports with only signature page sealed. APPZOVED CITY OF AT-ANnC BEACH BUILDII 4G OFFICE APR 0 7 2004 By: AAMA/NWWDA 101/l.S.2-97 TEST REPORT SUMMARY Rendered to: SIMONTON WINDOWS SERIES/MODEL: 08-08 TYPE: Poly Vinyl Chloride (PVC) Twin Casement Window System with Medium Structural "H" Mullion Title of Test Results Rating C-R50 73 x 74 Overall Design Pressure 50 psf Air Infiltration 0.01 cfm/ft, Water Resistance 7.5 psf Structural Test Pressure 75.0 psf Forced Entry Resistance Passed Referenc should be made to Report No. 05-30341.02 dated 03/28/02 for complete test specimen description and data. For ARCHITECTURAL TESTING. INC. Digitally sign-.d by Lynn George Lynn George, Project Manager LG:nlb i A& Architectural Testing AAMA/NWWDA 101/1.S.2-97 TEST REPORT Rendered to: SIMONTON WINDOWS One Cochrane Avenue Peruisboro, West Virginia 26415-9403 Report No: 05-30341.02 Test Dates: 02/06/02 Report Date: 03/28/02 Expiration Date: 02/06/06 Project ummary: Architectural Testing, Inc. (ATI) was contracted by Simonton Wilidows to perform tests on a Series/Model 08-08, poly vinyl chloride (PVC) twin casement "H" mullion window 3ystem at their facility located in Pennsboro, West Virginia. The sample tested, successfully met the performance requirements for a C-R50 73 x 74 rating. Test specimen descriptic n and results are reported herein. Test Specification: The test specimen was evaluated in accordance with AAMA/NWWDA 101A.S.2197, Voluntary Specifications for Aluminum, Vinyl (PVQ and Wood Windows and Glass Doors. Test Specimen Description: Series/Model: 08-08 Typ( : PVC Twin Casement Window System with Medium Structural "H" Mullion (Both vents hinged right) OveiallSize: 60-1/2" wide by 6' 2" high Casement Window Size (2): 3' 0" wide by 6' 2" high Vent Size: 2' 10-1/8" wide by 6' 0-3/16" high Finh h: All vinyl was white. 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com 05-30341.02 Page 2 of 5 Test Specimen Description: (Continued) Glazing Details: The vents were exterior glazed with 3/4" thick, sealed insulating glass fabri �ated with two 3/32" thick, clear am-lealed sheets separated by a steel spacer system. The glass was set against 1/2" wide double-sided adhesive glazing tape and secured with snap-in vinyl glazing beads. Wea herstripping: Descrii)tion Quantit Location 3/3" diameter co-extruded I Row Perimeter of vents hc Ilow vinyl bulb Ur long co-extruded single I Row Interior perimeter of vents leaf gasket 0. 187" backed by 0.300" high I Row Extenior perimeter of vents vi iyI J acket/foarn filled bulb Franke Construction: The PVC frames were assembled using mitered and welded comer construction. A rigid PVC drip cap was thennally spot-welded to the exterior of the head. Sash Construction: The PVC sash were assembled using mitered and welded comer cons ction. Mulflon Construction: The PVC H-mullion was fastened through the mating window jambs with ten #8 x 1-1/4" long screws, five per side, evenly spaced. The H-mullion was sealeii at the interior and exterior perimeter with a silicone caulking. Hardware: Descrii)tion Quantit Location Malti-point lock system 2 Each casement lock jamb M,-tal keeper 8 Lock stiles at 3-1/2" 24-1/2", 46", and 67" up from the bottom Stel snubber 4 Hinge stiles/jambs, 23-1/2" from each end Two bar hinge 4 Head/top rails and sill/bottom rails Rotary operator 2 12" in from each hinge jamb 05-30341.02 Page 3 of 5 Test Spe(Imen Description: (Continued) Drainage: DuscriPtion Quantit Location 3/[6" diameter hole 4 Each end of the bottom vent rail glazing pockets (through two walls) Rein *orcement: The mullion was reinforced with an 'T' shaped, extruded aluminum mern er measuring 2.839" x 0.625" x 0.125" (reference drawing #16990). The framemullion intersection at the unexposed side of the head and sill was reinforced, for shipping/handling, with a steel plate measuring 7/8" wide x 17-3/4" long x 0.060" thick. The plates were fastened to the window frames using four#8 x 1/2" long.screws per plate. Inst lation: The window was installed into a 2" x 10" wood buck constructed from Spiude-Pine-Fir #2 construction grade lumber and secured through the nail fin with 1-1/4" drywall screws spaced approximately 4-1/2" o.c. and sealed with silicone caulking. The vertical H-mullion contained two slotted I" x 2" x 0.060" steel angles at each end, fixed to the a uminum reinforcement with two 1/4" diameter steel pop rivets. One 2-1/8" x 6" x 060" steel base plate was fastened to the buck at each end of the vertical mullion using four #8 x 1-3/4" long screws per plate. Each base plate contained two tabs that interlocked with the slotted steel angles at each end of the mullion. Test Res Its: The results are tabulated as follows: Paraara-ph Title of Test - Test Method Results Allowed 2.1.2 Air Infiltration per ASTM E 283 @ 1.56 psf(25 mph) 0.0 1 C f11V fi.2 0.3 CfM/ft2 max. Note #1: The tested specimen meets the performance levels specified in AAMAINPVWDA 101/1 S. 2-97for air infiltration. 2.1.3 Water Resistance per ASTM E 547 WTP =2.86 psf No leakage No leakage 05-30341.02 Page 4 of 5 Test Results: (Continued) Paraunh Title of Test - Test Method Results Allowed 2.1.42 Uniform Load Structural per ASTM E330 (Permanent set measurements were taken on the vertical H-mullion) (Loads were held for 10 seconds) @ 22.5 psf(positive) 0.031" 0.296" max. @ 22.5 psf(negative) 0.067" 0.296" max. Gemral Note: No end measurements were taken on the member measured. Th e meaArements stated above include displacement as well as bending. This statement applies to ah Uniform Load tests performed. 2.1.7 Welded Comer Test Meets as stated Meets as stated 2.1.8 Forced Entry Resistance per ASTM F 588-97 Type: B Grade: 10 Lock Manipulation Test No entry No entry Tests B I through B 3 No entry No entry Lock Manipulation Test No entry No entry 2.2.56.1 Vertical Deflection Test @ 45 lbf 0.16" 0.71" max. 2.2.5,6.2 Hardware Load Test @ 5.0 lb/ft' No deformation No deformation 05-30341.02 Page 5 of 5 Test Res ilts: (Continued) P ar4j��h Title of Test - Test Method Results Allowed Optional Performance 4.3 Water Resistance per ASTM E 547 WTP = 7.5 psf No leakage No leakage 4.4.1 Uniform Load Deflection per ASTM E 330 (Deflection measurements were taken on the vertical H-mullion) (Loads were held for 52 seconds) @ 50.0 psf(positive) 0.568"* L/175 = 0.423" max. @ 50.0 psf(negative) 0.686"* L/175 = 0.423" max. Exceeds the allowable deflectionfor L11 75 but meets all other requirements of this testing. 4.4.2 Uniform Load Structural per ASTM E 330 (Permanent set measurements were taken on the vertical H-mullion) (Loads were held for 10 seconds) @ 75.0 psf(positive) 0.064" 0.296" max. @ 75.0 psf(negative) 0.168" 0.296" max. Detailed awings, representative samples of the test specimen, and a copy of this report will be retained )y ATI for a period of four years. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the above ref"erenced specification. This report does not constitute certification of this product, which m only be granted by the certification prograin administrator. For ARCHITECTURAL TESTING, INC: S� Digitally signad by Lynn George )J �' * Lynn Geo:rge Steven M. Urich, P.E. Project A/1 anager Senior Project Engineer LG:rjlb /P 7 05-30341.C2 DOCUMENT CONTROL ADDENDUM#05-30341.00 Current Issue Date: 03/28/02 Report No.: 05-30341.01 Requested by: Al Crum, Simonton Windows Purpose: AAMA/NWWDA 101/I.S.2-97 testing of a Series/Model 08-08, PVC H-mulled/twin casement window system. Issued Date: 02/21/02 Comments: Certification copy to John Smith at Associated Laboratories, Inc. Report No.: 05-30341.02 Requested by: Cindy Dotson, Simonton Windows Purpose: Revise Report No. 05-30341.01. Iswed Date: 03/28/02 Comments: Add Florida P.E. seal to report, Twelve original reports with only signature page sealed. FRCIM AMER I CAN WHOLESALE FAX' HO. :904 519 1301 Mar. �jl 2004 04:55PN P1 I 4& APPROVED CITY OF ATLANTIC 8EACH BUILDING OFFICE APR 0 7 2004 L4� BY: AA�MAJNV;WDA 101/IS.2-97 TEST REPORT SUADURY Rendered to: SIMONTON WINDOWS SERIESMODEL: 08-08 TYPE; Poly Vinyl Chloride(PVC) Triple Caaement Window with Integral "T" Mullibris RATING: C-R45 106 x 72 Title of Test Results QviralI Desiga Pressure .45.0 psf Air Mltmtion 0.05 cfiwft� Water Resistance 7.5'psf StructuralTest Pressure 67.5 psf Forced Entry Resistance Passed Reference should be made to Report;No. 05-30167.01 for complete test specimen description and data, For ARCHITECTURAL TESTING,INC.. Lynn George,Pfojec'T Manager Mop FFOM AMER I CRA WHOLESALE FAX' �-40. :904 519 1301 31. 2004 04:55RII P2 Architecturai Testing AAMAZ 2TA101/1,U-271ESTREPOR Rendered to: SIMONTON WINDOWS One Cochrane, Avenue Peansl>oro, West Vixginia. 26415-9403 Report No: 05-3 0167.D I Test Date: 01/17/01 Report Date: 02YO9101 Expiration Date: 01/17/05 Project Summary: Architectural Testing, Inc. (ATI) was contracted by Simonton Windows to perform tests on a Series/Model 08-08,poly vinyl chloride(PVC) casement window with integral "T" mullions at the Simonton Windows facility located in Pennsboro, West Virginia, 7he sample tested sudcessfully met the performance requirements for a C-R45 106 x 72 rating. Test specimen description and results are reported herein. Test Specification: The test specimen was evaluated in accordance with AAA4"1WVMA 10 11I.S.2-97, Voluntary Specificationsfor Aluminum, Vinyl(�VQ and Wood Windo�vs and Glass Doors, Test Specimen Description: Series/Model. 08-09 Type: Triple PVC Casement Window with Integral "T" Mullions Overall Size: 8' 10-1/2" wide bly 6 010 high VentSize: 2' 10-1/4" wide bY910-1/4" high Finish: All vinyl was white. Gla:zing Details:' The vents were exterior glazed with 3/4" thick scaled insulating glass fabricated'with two 3/32" thjc�clear annealed sheets separated by a steel'spacer system. The glass was set against 1/2" wide adhesive giazing tape and secured with snap-irt dual durometer vinyl gla7l'Mii 6ads. 130 Perry Court York.Ps;174=-9405 phome- 717.764.7700 fax., 7'17.764.4129 FRON AMER 1041 WHOLEGALE FRX NO. :S104 519 1301 N;ar. 31 2004 04'75-GRI P�j Page 2 of 4 Test Specimen Description: (Continued) Weatherstripping: Desedl2tion Quantity L ac—at J 1J4" co-extruded I Row Interior perimeter of sash flexible vinyl leaf 3/8" co-extruded I Row Perimeter of sash flexible vinyl hollow bulb 0.187" backed by 0.340" high I Ro* Exterior perimeter of sash center fin pile Frame Construction: The frame was assembled using mitered and welded come r construction. Sash Construction: The sash was assembled using mitered and welded comer construction. Hardware: Desctiption LwWgn Multi-point luck 1 Locking Jamb Plastic lock keepers 4 Locking stile at 3-5/811, 25-11211, 47-3/8" and 69-114"up from bortom Steel sniibber system 2 Hing stile/jamb, 23-1/211 from each end Hinge Mtem 2 Head and sill, one per end Roto-operator I Sill, 12" from hinge jamb Drainage: Loca -tion 3Y 16" diameter 2 Each end of the bottom rail gl o pocket(thru two walls) Reinforcement: None. Installation: The window unit was installed into a 2" x 10" wood buck constructed frorn Spruce-Pine-Fir construction lumber and secured through the nailing fin with 1-1/4" drywall screws spaced approximately 4-1/4" o.c. and seal-ed with silicone caulking. FROM AMER I CRN AIOLES�LE FRI� tAO. :904 519 1301 1-1-ar. —J1 0-00-4 04-5t--PM P4 Pag of-4 Test Results: The results are tabalated as follows: Paragrap Title of 7mt- ;zt_Nlethod Resuht Allowe 2.1.2 Air Infltration per ASTM E 293 (See Note#1) @ I.S7 psf(25 taph) 0.01 C�� 0.3 cfmft�m:LK. Note h1l: The tested specimei.; meets (or exceeds) the performance levels specified in AAI�WAVWDA 2-97fop-air irifiltratiosi 2.13 Water Resistance per ASTM E 547 WTP= 2.86 psf No leakage No leakage 2.1.4,2 Uniform Load Structural per ASTM E 330 @ 22.5 psf(positive) Negligible .313"max @ 22.5 psf(negative) 0,006" .313" max. 2.1.7 Welded CornerTest Meets as stated Meets as stated 2.1.8 Forcod Entry Resistance p er ASTM F 588-97 , Type- B Grade: 10 Lock Manipulation.Test No entry No entry Tests B I thru B3 No entry No entry Look Manipulation Test No entry No entry 2.2.5.6.1 Vertical Deflection Test @ 45 ibf 0.04" o.7111 2.2.5.6.2 Hardware Load Test @5-0 lb/i? No darnage No damage Optional PerfoMance 4.3 Watd'r Risistanct,per ASTM E 547 ,W,rp= 8.25 psf No leakage No leakage 4.4.2 Uaiform Load Structural(Lock Stile) @ 82.S psf(posilive) 0.0441, 03 1 max. @ 82.5 psf(negative) 0.028" 0.313" rna:-,. FROM AMER I(-,PN WHOLESf;LE FAX' HO. :904 519 1301 Mar. 31 2004 04:5GRI P5 Page 4 of.! Detailed drawings, representative samples of the test specimen, and a copy of this report will be retained by ATI for a period of four years. The above results were secured by using the designated test methods atd they indicate compliance with the performance requirements of the above referenced specification. Ms report does not constitute certification of this product which may only be granted by the certilucation program administrator. For ARCHITECTURAL TEST N- G,.NC- gob L�Fnn George iv fo?-A. WaMeT Project Manager Executive Vice President LG:tp 05-30167.01 Ap r� 1. 2004 1 49PV No. 0918 P. I APPROVED LAFY Or ATLANTIC 6EACH BUILDING OFFICE APR 0 7 2004 BY: TES".1'PLE2ORT Reade-rad to: SLM0, 1',T7QN* 'WINDOWS SZF,JESrVJ'10DE41:�,: 07-07 TY?h': :PVC SILA-Lu,-, Glas� Door('Zo*), with ES 11'.einforcewelit. Suminarr of Zsults Title Te�ts.vecimenii 7Test Specimen#2 AAMARatiag SGD-R40 9:5 x 79 SGD-R50 71 x 79 Operating Force 15 lbs NIA Air Miti-at0n ).09 cfin/ft.' N/A Water Resistance Te A Pressure 7.5 NIA Uniform Load D(�flectiorL Test Pressure _40.0 psf —50.0 PSf Uniform Load Stractural Test Pr=ure �_60.0 psf ±75,0 psf N/A L F orced Entry R ist=ce Grade 10 T_ NIA Reference should be made to ATI Repoit N:)- 05-30439.0,1 fcr complete test specimen description and data- A P r, 2004 1 50PM No. 09 18 P -2 R Architec.turaj Testing AAMA/NNVWDA 1 0L)"T.S.2-97 TEST REPO]CT Renda-rcdto: SNONTCM '�'YINDOWS One Cochrant� A-vermt Ptnnsboro,West I/irg,'fflia 26415-94C3 Report No: 05-3 04')9.04 Test Dates: 09/19/02 , A�d: 10/10/02 ,port Date: 11/07/02; Ex�L`ration Datz: 09/19/06 Project Sammary: -krchitecti:.T,� Testing, -Imc, (,kTI) was contra,.-ted :)y Simonton Windows to wi-mess performance tests or a Series/Mod& 07-07, PVC slidiiLg g.a5s door at dieiT facility located in P,-�.,-msboro, West The tested succ2WLJJy met the pe5ormance requi=ents for Lhe followirizu ratings- Test Spec:iiT.�.en 41 SGD R40 95 x 719; T��st Specimen 92 SGD R50 71 x 79. Tt�st specimen descriptionz ,;nd resultz- are ci-,po�Led 'lest Specificadon; The test specimen was er,,Lilv).aLed in acl�or(LarQ' wit A-kN(A^I-WV-TC-A 1 Ol./I.S.2-97, Poluntary speci fivatiorsfbrAlurunum, /inyi(PP(7) ind F76od Tirdowy ,2nd Glass .Doors. Test SDCCiMeU Description: Series,'.Model: 07-07 Type., Poly Vinyl Chloridt (PVC)Sliding (--'rhL3s Docr(XQ)w.iTh 115 RQ;inforceilent Test Specimen 41: SO-D F,40 95 x 79 OverallSize: 7' 11-114" wide by6' 7-[/,I"high Operable Panel Size- 3' 11-112"widtb- Y3--I/F'hiah Fixed Panel Size: 4' 0-3/4" wide by 6-4-1)2" �ipJ Screen Size: 3' 11-1/2' wide by 65-5/16" high 150 QF-,rry Court York, PA 17402-9405 phorte, 717.764.7700 fox:717164.4129 wvW,archtesI,corq 2004 1 : 50M No. 09 18 P. 05-30439.04 Pagc 2 of 6 Test Specimen Description: (Continued) Test SPecimen 42- SGD'Z50 71 x 79 Overall Size: 51 11-1/4"-1vide by 6'7-1/4."' high Operable Panel Size: 2111-1/2"wide by 6-3-1/8"high Fixed Panel Size: TO-3/4" wide by 614-.[/'2" high Thefoll)win-descriptions-i ly to all specimi its. 'PI Finish: Ail vinyl was whi�e. Ghrzing Details: The operable and fix0d pan.-Is were exteri(!r glized with I" thick, sealed- insulating glass fabticatecf, from two M�," Giicic, clear teTrper�d sheets separated by a desiccated foana spacer sygtem. -1-lie glass �vas set against dou�le-sided adhesive Slazin,- -P tape and secureci with snap-Ln dual durorrit;t-.r ,Ja2ing beads. We2therstripping: D ouaig*t'� Locatic!r, 0.187" bac,cedby 0.3 00" 2 R�ows Exttric r mi t-ting stile; hoad. sill' .,high pile withcenter, fin jarrib;c,pcn.b.-t��)ariel rails andjamb stile 0.1877 backed by 0-300' 1 R jw Fixi�d-',ane� rai2s atid j arnb stile high Pile with center a Frame. The PVC frame �Yas asserribled usir)g (�oped, mechwiical corner consiraction, fastened witb four screws ptz, end. The fra-ni� iatcr:ectlons contained a fbarri ga.skat at the head, and foam/butyl gm- kctsat tae sill'. A snap-:n, PVC-L�reshold was located at The bead and sill at the c,perable panel. The f=d puriel. wm scsured at d2e jamb using a continuous extruded alurrii�ium angle cEp. �114- cdp was fasteaed with six screws, three per leg, two at the top a�id botnm, and two at inic.'I.,;7paa. A coritinuoiLq extruded aluminutti fixed lite anchor was located at tie head and sill at lJi�� --.ixed panel. T e panel was fastened at the .th extetior through the aliurriiatim anchor Aith nght screws, fcur tach at the head and sill, evenly spaced. A snap-in .?VC cover/beai was located at the extnior of the fixed pariel at the head and sill. A sWnle;3s steel roller track wa� applied to the Ir.terior track of the sill. Panel Construction: The PVC panels were assembled using mitered and welded corner construction, Apr. 1. 2004 1 : 50PM No. 0918 P, 4 05-3G43M4 Page 3 of 6 Test Spccf men Description. (Continued) Screen Construction: The screen was cons:xucted ftorr. rol-formed alumixwm. The comers were square cut �md secured witi-I pJastil Comer ke�s. 17ibermesh screen cloth.was held-in-place with a flt�xible vinyl spline. Hardware: D cri tion Q_U! .,.III Y Locat�.on Dual adjustable steel roller .2 Activ,�pa iel bottom rail,one per end Lock and handle set with Operzble )aneljamb sti1c, dual adjustable latches approcim Aely 40" f1rom the sill Metal keeper Jamb, apf roximately 40" fi-om the sill Spring-loaded- Tcp aid b ottom screea rails, 4" :torn adj-Ligtablc roller each�nd Drajn2ge: Description ou�ntit,, LocatJoll I" wide by 3/16" 16 Exterior&il face, one 3-1/2" froin high weepslot each tmd; Interior s.,ql track, one at each end (!xte-ior slde); Sill inttrz.edi,te walls (6),ono per tmd 1!2"wide by 3/16" Interic.r si)I track, one at-.ach end deep we-lpslot (interi,)r s-Ide) -n;, 1/8" diameter weepholc Sill parti .,track, one at each end 1/4"diametcr weephole Activc p&el bottom rail,iwo per end Reinforcement, (Simonton Code H5), '.."be fix-,d and opera:Ae pariel jarrib stiles contained a "U" shaped, roll-65nncd, steel rcinfomn-aer.t measuring 1.500" x 1.850" x 0.060", reference drawing #BLK. PD07STL6. TE,� interior and exterior meeting stiles contained a "U" shaped, roll-formed, double-wall stte';. reinforcement m(asuring 1.50011 x 1,9501, x 0.060", reference drawing#BLK.PD07;3'FL7. 1 2004 1 50PV No. 0918 P. 5 O�-30439,04 Page 4 of 6 Test Specimen Description: (Continued) Installation: The u-6t was installed ii.tc, a wood 'cuck cc nstracted from Sprace-Piae-Fir construction lumber and 5ealQd at the ey. and interior�eiiij ietai-with silicone caulking, with the exception of an, approximate 6" lung.void a:t each uiaterix sill corner, The unit w2s secured to the test buck dLrough thejatnb�z usbag foux �t8 x 2-1/2 long sorows, oni� at the top and bottom of eaclijarxib (screws embed4l�,d z.pproximately 1-1/2" into the buck). Test Results: The results are tabulated Es follows: Paragaph Title of Test- Test Metk.'od Rtsull,s Allowed Test Specimen #1-. SGD .R40 95 x 79 2.2.19-5.1 Operating Force *, open 18 lba 30 lbs mix. TU mot 20 lbs max. ion(Opening) D lbt; In mot!on(Clos"Ing.) 15 lbz� 20 lbs max. i.2 Air inflint.on, (AS'LLY1 E 2-K-9'.)* @ 1,.56 p,,;f k"L.5 mxh) C'.09 cfir./.-ft2 0.3 cfm/ft2 max. Note #1: The tested spe,7`7nen ;-neets Oie.perfbemarce level,7 qj)ecb6ed in 10111,S. 2-97for air infM'7 ation. 2,1-3 Water R�-�is canc e (�kS T-1�f 11E 547-00)" (with and without s.-.�reen) WTP=2,86 psi' NO leakage No leakaaa 2.1-4.2 Uniform Load Structural(A�':!TME ')')0-97)* (1vi!-asumments reported vvi�rizl taken on the �,ced meeting stile) @ 22.5 p,<f(positive) 0,041" 0.306"i=x. @ 22-5 pd(necTative) 0,056" 0.306" max. 2-2.19.5.2 Deglazirig Test (ASTM E' 98 7-94)* Inopezat�igdi-re-.tionat"1011,)s Meeting Stile 0,0 1011/2 IN 0,50011/100% Handk Stile 0.010 0 0.500,11100% In remaining direction at 50 lbs Top Puil 0.010"/2% 0.500"1100% Bottorr.Rail 0.01011/2% 0.500,11100% AP 1, 2004 1 5OPM No. 0 9 18 P. 6 05-30439.04 Page 5 of 0 Test Results: (Continued) Paragrap Title of T-.st -Test Methi)d Reswt, Allowed Test Specimen 41 SGD R40 95 x 79 (Coadrtwtd) 2.1,7 Welded C orner Test* Meets as s-.ate( Meets as stated Z1.1.8 Forced Entry Resistanc(� ',Af 77M F 842-9'7)* Type: A GTade: 10 Lock'Mai-Epulation Test No ently No entry T,�sts Al hrough A6 No entry No enixy Lock Maripulation Test No entry No entry Omional P-,rTormance 4. Water Rnzist,-irce(ASTIv.' E' 47-00) (with and withot-A screen', 7,5 P S f !,,Io leakige No leak-age 4A.1 UlniforzmL Load Deilection (A,'-TtA E 33Q-97)4 RAeglarer imits rTortcd x-.11M iakea on the fix.ed i ieeting.itile) (Dy 40.0 psf(positivc) 1.3 9" See Note 42 @ 40.0 p.5f(negatiive) 1.381, See Note�2 Note 7he Uniform Load Be flictzon ;'eslt is not an AA.IZAMW71DA 10PIS-2-917 reqvirement for zhis prcduct designatio.n. 7he data is rec)rded in this r,�port fGr information oniv. Unifon-n load Structur I ',4S­AvI E 330?.97) (Measizerlents reported ,�v,u�:: taken on the fl,'.Cd I.Iocting stile) @ 60.0 pa�1'(positive) Q.197 0.306" max. Ov,60.0 p&:*(ncgad-vre) Q.051" 0.306" max. Reference Report No. 05-3 04,39.01 for these (est results, Reference Report No. 05-30439.03for thev test reSulls..,., Apr, 1. 2004 1 : 51PM No- 0918 P. 7 05-3,0439.04 Page 6 of 6 Test Results: (Continued) Paragraph Title of 'est-Test Method Results Allowed Test Specimen 92: SGE R50 71 x 79 Optional Perfori-nance 4-4-1 Uniform Load Deflection.(�'-..ST:q E 330-97'*** (Measurements reported were takmon the ixed inreting stile) @ 50.0 psf(positive) 1.09, See Note#2 @ 50.0 psf(negative) 1.46' See Note#2 Note #2: The Unifori? Load Defiea�:'�,n te6r is not ar A-,J1L41NWWDA 10111,S.2-97 requirement f�r this pr9duer designaj,�r, The dal�a i.-- re,,orded in thi4 report for informatior anky. ? Uniform.I,oad S' ctLzal rAl:�TM Z 330-97)* Eru (-Mcasu.-emews reported,weie taker-on tLe f xed metting stile) @ 75.0 p�ff(positive) 0.068 ' 0.306" max. @ 75.0 p:;f'nt-.gati e) n -V OAZ6' 0306" ma-x. Report No, 05-Z0439.02fior ;r 03t wesuits. Detailed drawings, representative swipleS Ot the TeST Specimen, znd copy ofthis report wi-11 b'2 retained by ATI for a pericir' of four years. '1he above rtslilts were secured by 'asing thLe designated tast methods and tLey indicate co.-inph.anc;,- wiLh the p-rfoi m, azice requirements of the ahove referenced specification, This report ILOt COnStit%t..- Ultification of this p-1-Oduct, which may only be gninted by die. c--itification prog-arr, adzn.ini,,ztrat(r. This ropor i-�iay wr bt� r--produced, except in full, without the�lpproval estil 1g. For ARCHA"TECTURAL TESTLNIG, INC: Digitally Signed by Lynn Gccr�a Lyrm(�eorge Project Manager Director-OPei ations LO:n$ 05-30439.04 3)'-OX.*AX41 Map 4D a kill IPA. 4r s 1.25 AOL 0 dL r el AWIXRING MSS SECDONS Ly.1 kid FOR .Ix St CK TO MCOWY On* Cochrww Avon Lm PeAnsbom, WV 26415 DOUDED WMI PH, $00.426.2249 195M F 1-910M PATIO DOOR Lift. FL 335W 7An 'ON1 g. :7, to 07, dV A p r. 1 2004 2: 2 9 P V--. — No, 0920 P, 1. FLORIDA CUSTOMERS RETROFIT PATIO DOOR .See Note) NSTALLATION PROCEDURE .71ox W 12-�(A) —6� LI I-owo M A: flO X 2-1/12'FASTENER AWCHORNC FRAME J HEAD AND JAMEIS� B: ANCHOR R THE HEAD AND SILL TO 71�E 2X WH A #10 X 2-1/2' 51*,*(:Vl AND USE A 2�,/2!HX w; -T,,ON TYPE ANCHOR F(R ANCHORING HEAD AND!ikl.JY)14AWIRY IN IX CONS701H-nIOK. C.- INSTALLER MIAT I'MRICATE INSTALLATION i4OLES AND ANCHOR AS OWTUAl")A00C, APPROVED GITY OF ATLANTIC BEACH BUILDING OFFICE APR 0 7 2004 L,4� 61 M E 113 86-97 AN 1") ASTM E 1996-01 Uf S'T REPORT SINIONT(),N WINDOWS SERIES/rv.101)EL: 0809 TYPE: PAlC (',asemeutlVlnduw Report No.: 01-42204-03 Report Date: 08/22/02 Expiration Date: 07/1-9/06 ZTd WdTS:SO t7OOE TZ '-APW T02T (STS t706: 'ON XUJ 37US37OHM Nb3Ia3WU: WOdJ Architectural Testiog ASTAi j: 1886-97 ANDAIA]IJE, 1996-01TESTREPORT '�ci-id et ed to: MONTiYN' W1NDOWS One Cm-hrallae Avenue Pennsboro, Vy'e�t Virginia 264'.5 Report'No: 01-42204-03 Test Date&: 07/15/02 Through- 07/19/02 Report Date: 08/22/02 Expiration Date: 07/19/06 Pr9ject Summary; Arch,teclural Testing,, Inc, (ATI) was contracted to perform,tests on diree &ries/Model 0809, PVC casement witiclows. The samp.es tested successfully met tile pt�rformance requirements set forth in the refC.Tenced specifi�ation listed below for a design pressure rating of 50.0 psf Sp-.cimens uti liquil tel,.)Jacernent corstruction, Test Specification: The U;st s-)ecirnens mlere t�vaAiated irl accordance with the r-ollowing: ASTIVI E 18 86-97, Standard Test iWetAtod,for Pe)fbrivaj ice of Exterior Windows, Curtain Walls, Doors and Al'torivi Shuiters J1)y)acic,?d by and L.rj)osed to Cyclic Pre,�sure Differentials. AS".rM E 1996-01, Staiidat,dS�ecifi(,,4-iti,,)�,jbr Perforniance qj'Exterior Windows, Gla2ed Curtain Walls, Doc rs and Storm SlIuVor.s,,i5npacted by Plind Borne Debris in Hurricanes. Test Specimen Descriptic a: Series/Model, 0809 Type: PVC Casei-neni Window Overall Size: 21 6"wide ty 5'5" high VentSIze: 214-1/4" mideby5' 3-1/4"hii.-Ii Finish: All 'PVCwas xhile. GlazingDetalls: The ven: utilized a I" II.A.A. insulating ghss unit fabricated frorn a sheet of 1/8" thick, tempered g�ass Oil tile exterioraj,'.111 two shects of 1/8" thick, clear annealed glass with a 0.090" thick intorlayer on the hiterior. The insulatinE,glass unit utilized a Boarn.spacer system. The vent wa., cx�etior glazoi against a glazing cooipound and secured with du�jl durorneter snap-fit gl&-ing beads. 130 Deny Co.irt Yon,, PA 17402-9,105 pho w: 717,764,7700 fax; 717,764.4 129 �Aww,ar�Mest,(Orfl WdTS:SO VOW TZ "JPW TOLT (STS POE,: 'ON XUA 3-lUS37OHM NUO163WU: W06A 01-42204,03 Page 2 of 9 Test Specimen Descriptio it: (Continued), Weathers trioping Loc itioti 1/4" high custom hollow I I-Kov" Co-,,,xtruded onto vem members bulb gasket 3/16" high custoin I R.0 Perimeter of vent vinyl wrapped foan gasket with dual fitis 3/1.6" high custom I Row, Co-oxtruded onto.vent members single leaf Frame Construction: A.11 vinyl was cioi-asltructed of ex1ruded vinyl. All comers were mitered. and welded, Vent Construction: idl ,�inyl was coi1,stra,,,i,vd of extruded vinyl. All Corners werd rnitered and welded. STCJ kjcjZS:S0 t7OOZ TZ -Lew TOET ESTS VOE:): 'ON XUA 31US37OHM NUDIH3WU: WOaA 01-42204,03 Page-'� C3 1'9 Test Specimen Descriptio ri: (Continued) Hardware: Qe-8—Cr i at i-(—),I (Lgant j ty Loc;ition Metal rotary operator At s1l, fastened withfiveft8 x 3/4" scrows mid ow 4-8 x 2-1/2" screw; stLid bracket and track were fastencd wiffi three 48 x 3/4"scrow8 each Hinge assernbly Head and sill corners at hinge i amb fastEned with four#8 x 3/4" screws into the vent, two.#6 x 1/2" screws and .-iV-IILILS, ono#7 x 1/2" screw and-)ae #8 x 2-1/2" screw in the fram e Interlocking nietal 3 sets One 23" frorn each end andnlidspan snubber of the hinge janib/sti Ic fastened with two �8 x 1/2" screws into the vent. and Imne Metal lock handle LocIjarrib corner fastened to the assembly fram c wi th two#10 x 1/2" screws Metal tie bar 1. Lock j anib fastened with one assembly #8 x 1-1/4" sciew and one 48 x 3" screw in each tie, bar guide Metal keeper 3", 39" and 59"I�oin the bottom of the lock stile fastened with two #8 x 3/4" screws each 8" impact nietal 3 Sets One set 9" from each end and snubbeT midspan, of the lock ja�:nb/stile fastened to the fratne-with two #8 x 3/4 and two #8 x 2-1/2" screws each; fastened to the vent with four #8 x 3/4" screws each qTd Wd8s:so Vow TZ TOET GTS POS: XUA 3-lUS37OHM Nb3IN3WU: WMiA 0 1-42204.03 llagt 4 o(9 Test SpecinienDescription: (Continue(l) Drainage: Description Qlar-ti��v Location 3/16" diameter 2 1-5/16" from ends of bottom rail draining the glazing channel weephole Reinforcement: No jeinfbrceineiitwal�; tit,�.�.i,�ed. Installation: The reli lacenient.window installcd into a noniinal 2 x 10 Spruce-Pine-Fir #2 wood test buck, The licad was soctuud with one # 10 x 2-1/2" screw 6" ftoni each end and in the second hol-, from the end ir, th,z Aitige track, closest to the inidspan of the head. The j am.bs was faster ed with one #10 ;� '2-1/2" screw 6" fi-om each end and 3" above and below the jambs midspan, The hingt:jarnb was fuii�her fastened with one 08 x 2-1/2" screw in each end of the 8" jinpact snubber,,. Ilw Iockjamb was Further fastened with one #8 x 3" screw through each tit! bai- guide. Th,.- siti ivas secured with one #10 x 2-1/2" screw 6" froni each end and one#8 x 2-1/2" screw tKrot,,g,,-. Ie operator and in (he second hole from the end in the hinge track, c osc:,t to the of the sill. All the screws titilized a 1-1/2" embedment. The interior and exterior periw,oters wore sealed with silicone. LTcj wdes:se vooF- TE -Lew TOET 6TS N7b: 'ON XU-� 37US3-10HM N031d3W: W06J 01-42204,03 Page 5 or 9 Test Results: The resu Its are tab ul ai ed z s fo Ilows: Lab Temperature at Time of Test- 81"Y ASTM E 1886, Missile Impact, Section I 1- Test Procedure Missile Weight: �)-O lbs Muzzle Distance frow Test Specinien: ;4.5ft. Test Unit 41 Inipact41- MissileVelocity: ff) 63fps Iml act Area: Cexiterofj..�tass Obi ery ations: Large, t-nis)sile shattered -Xterior lite of glass and fractured inte-ior lite of glass, ric pnietration. J'Iesults: Pass Impact#2: Missile Volocity 5C) 41 fps bnj act Area: lJpl,,cr righi comer Ob!ery ations: Large nkis.si Jo fTactured interior lite of glass, no penetration. Results: Pass Test Unit#2 Inigact#1. Missile Vclw.ly: 50,76 fps Inic act Area: CetiWr of Wass, OWervations: Laige rnis,file shattered .-xterior lite of glass and fractured inte)ior lite of gla&;,no ptuetration. Impact#2: Missile Velocity 49.18 ,fps ImpactArea: Lovyertig;a� comer Obs ervations: Larp rrds,si le fractured ir.Wrior lite of glass, no penetration. Results: Pass Test Unit#3 linL )act #1: Mi3sile Velocity: 49.75 fps ImpactArea: Cenlerofl-,'ass Obs�.-rvations: Large nr.ssilo shattered oxterior lite of glass and fractured intet ior I ite of glass, tic,p�!.aetratioxi. Rtesults: Pa:is Impact#2: MissileVeloc.ity: 5(j.,39j* IniptctArea.- Low.-rh-f, comer Obsorva tions: Large niissi 1.e fractured iii:orior lite of glass,no penetratioii, lkesults: Pass 8Td WdEs:so VOOE TE WET ESTS �06: 'ON X1dJ 3-IUS31OHM NUOI�BWU: WO�H 0 142204.03 Page 6 of 9 Test Results: (Continued) ASTNI E 1886 Air Presst ire Cycling Desigu Load: 50.0 ps.:' Test Unit#1 Table I "Cyclic Presv ire Dilrerential Loodbig", Section I Paragraph 11.4.2 POSITIVE 2�,.C'TING Hinge Stile MRX113111111 Deflection Permanent Set Pressure Range No, of Cy de Indicators (Psp Cycles Ti;ne Nli.ddle .-Bottcm Top Middle Bottom (seccuds) ff 1 42 #3 1 #2 #3 10.0 to 25,0 3500 L,t 1 0,011, 0,07" 0,011, 0.0 to 30.0 300 1 0.02" 0.0 8 0.0111 25.0 to 40.0 600 L"q 0.03" 0.0911 0.02" 0.1011 0.01" 0.01., 15,0 to 50.0 .:;-91 4�- (Y 0.03 Pass - ------- NEGATIVE .4CTINC j!!aae Stile Permanent Set Pressure Avevagc Maxilnitun Deflection Range No. of Cyle Indicators (ps Cycles Tij ne Top_.__ Middle Botto ni To­v- Middle Bottom (seconds) #1 42 #3 #1 #2 #3 15.0 to 50,0 50 2.� 6 0.0511 0-30" 0,03" 25.0 to 40.0 1050 J,S2 0.04" 0"M11 0,031 0.0 to 30,0 50 2.1 0 0.0311 0,02' 10.0 to 25.0 3350 LE 0 0.02" 0,1 9ti 0.02' <0.01" 0,06f 0.011, F L< I Pass 6TJ WdES:SO t7OOE TZ 'UPW TOET GTS 'ON XUA 3-1US3-1OHM NUDIa3WU: WOaJ 01-42204.03 Pagr 7 of 9 Test Results: (Confinuod) AST*M E 1886 Air Pressi ire Cycling Design Load: 50. ) ps C Test Unit#2 Table I "Cyclic Press,.jre Diffierentiai Section P. Paragraph 1.1.4.2 POSITIVE Jlk A"ING flinge Stile Permanent Srt Ave-age Maxinlimn Deflection Pressure Range No. of Cy Cle Indicators Cycles Ti.ne Top. 5,11iddle Bottom To Middle ottow 'Ile (psi) I (secc nds) #1 :92 #3 #2 H3 10,0 to 25.0 3500 L59 010111 (.0511 0,011, 0.0 to 30.0 300 2.�O 01011, 0.05 0.011, 25.0 to 40.0 600 1. )1 0 01 0-05" 0"" 100 0.03-7 <.QV, 15.0 to 50,0 _2.02" 108" 0.0�-,, <0.0111 Pass NEGATIVE ACTING Hinge Stile Pressure Ave;-agc T I Ylaximmi-I Deflection Permanent Set Range No. of Cy-.1e —Indicators (ps 0 Cycles Tij ne Top ddle Bottom — Top Middle Bottom (seco ads) #1 42 #3 #1 #2 15.0 to 50.0 50 2.:18 0.04" Q96" 0.03" 25.0 to 40.0 1050 2.00 0.011, 0.011, 0.0 to 30.0 50 2.�,2 0.011, 0.71" 01011, 25.0 3350 I.S7 0.01" 0.54" 0.011, <0,011, 0.30ti I <0 0111 Pass OEd Wd2S:S0 t700E TZ TOET (-,T-S t706: 'ON XUJ 3-lbS31OHM NUDId3l4b: WOaJ 01-42204.0 3 15age 8 of �d) Test Results: (Cwitinti,. ASTM 1411886 Air Pre,-suro Cycling Design Load; 5),0 psf Test Unit#3 Table I "Cyclie Pre�sur?Differentia Loadii,,g", Section. 11. Paragraph 11.4.2 POS rrIVE ii.(J"ING Hinse Stile Pressure A,,era:,Ye Maxiiiannit Deflection Range No. of Cycle Indicators (pso Cycles '.1111v �Ytjadle Bottom To Middle Bottom (seconds) #1 42 #3 41 #2 #3 10.0 to 25.0 3500 Z.02 -0.01 , 0,03" <0.01" 0,0 to 30.0 300 1.14 <0.01" 0-103" <0,01" 25.0 to 40.0 600 1.81 <0.01" (1,03 <0�0111 1 0.031, <0,01" Pass NEGATWE ACTING Hinge Stile Pressure A.,crage M qh�att m.Deflection lermanent Set Range No. of Cyclv Indicators (pst) Cycles I,Imc- Middle Bottom Top Middle Bottoin (se�,onds) �j!2 #3 #1 W2 15,0 to 50.0 50 ..89 <Ull, 0.74" <0,01 25.0 to 40.0 1050 -'1-35 <0.0 I I �72 11 <0.01fl 0 0 to 30.0 50 �-15 <0.01 (1XW1 <0.01" .0 to 25,0 3350 '�.03 <0-01" �,.J 3 <0.0 0,26" <0.01,- Pass TEd Wd2G:q0 tPOW TE 'uPW 102T STS VOG: 'ON XHA 31US37OHM NHDIZ�3WH: WOHA 11,40m" P. 007 R w R W Building Consultants, Inc. B Cmnkmg amd ftneering S"ces for the BWIMS ln&t*y c P.0.Box230VahicckFL33594 PhemB13.639.9197 Facsfinile 813.659.4959 4,P P R 0 V E D 9jjQD=!S moracs or my""=#TH-aff ( 11", J, ATLANTIC BEACH BUILDING OFFICE Tbmua-Tm Cop. 109 MWOMd P"d APR 0 7 2004 EWer,IN 46721 pbowwl.ga.-Mll FaWnWe260.8".3190 GH 0009mm 01f Um MWjd Dedpa*m F*a Ch=rJ ftootb Sor,San Mm*=Dow(aw,4 WA Of WW"SW0-hW M[odimant OwnA 14mbd Sim op to V4 z" U$WW 10-Oft Cmftwgkm X,OXO,XG-OXXX'&OXXO cpawd bescrodw Tw bend ndjanft an wood mmwft 43"x 1.25"wkh in amrsdod slonvintme dwedm9A TbO door pavj*nd Aftbtepends an 16r dd&andcondst ckf two SbAC ddRSVOS tbdam 0(006r fbrfbeFlbwa� Swig$ or the Smooth Stu Saft with a dda tbidamof 0.07(r. Sbwwe&W10wo0d98W&dMbwkh*umthmwm The emid ddebw m mded lo vocehv j1r"gVWW OF W"12M&W mpg*p m4lip We bmU or iaugw fbah Ond NO W, redbylUmmi-Tm VW ftain IM MMedWb Md Ammdk Tedc' (IW7.4.3 Door 17D7.4.5 Muffiam Dooc AnewhUM) Ted DUQ*W Tat LAodwn Doo vA*bm Sudc NCTL-Odeade Mly 3k M7 2=1-4 boy pedmacy,nast Air Fm� CM-Rodwopt.NY jm*22,2001 . TMA -741.1 lW2.0 Dddw4 FZ 0429V NCTL-Odamb Jday30.1997 2104940-1234 110"pabowJ16258 TA32M FopowdEwy VM-RndmdwjNY Jmw2-L=0J ETC-01 -- jamb DJdw%PJL 0429M Wdw L_OjiwW May38,1997 mmy raftcey,01623V AgME331 NCM-OAM& 210 .0 .042M F—' d . EM-R***" Jw*22.X01 1 1%1�741-110011 Jm*DoWk NY 94 RmYpw #16M NOL-Ormak May3Q.M 210-1940-1214 AIMEM Airl 0 S ZlU-Rp&cdwNY Jm*22.2001 UMAL-741-11006.0 *AMb Dakift M 142929 TAX201aU -Larmw" MA MA MA WA EEO - mo=WdmwowWmadvAetg%of?oWd"DsdpPomm *wjbbpffedmdmwbcdmwmdwwM I "-- conapmd" Wimimum Size Dedp Pjaman Rating ahmwsim& x UpTo3'Ox6'9 +47.00-47.00 Maud Shab vmh SWcLW= MD,ON,0X0 To 5-4 x 6'8 +4700-47.00 Ahm AstmSd AIDS Gbad DW*wM SWdft OXXO I UDIWV4 x 613 +40-00 -40-00 1 +47 00-47.00 i.Bvgwbd hr=in locadow ademag to tM Ron&BWWWS CO&And wbOm 9 010ftemew w dzismi"d by ASM 7 MW�bev�p Lee&hrBm&&W Wd Odwr Stnuftm cb wimmmd ft dmP F P1 "MPUded Abom 2.ForMomy huWbdan what the SW�-W&is Im dw 1-1/2 indw OW secOm 1707.4.4 Ambomp Mdhods Mod sWmwdm 1707.4.4.1 and 1707.4.4.2)=m dkmww Tapow AYM axam mcbm not be Mskim A MOW ift L-01111111 MW be sub*K a rAnimm MAC ar4pgmm d do IWM Into do mommY WA is d3mimt 4��Aoole— Cadleadmw plo"pmhsdoma Rogkww - Sed No.4340 May 22,2002 Lyndon F.Sdmidl 19s06 Fvmh LAw Dd" Lutz,FL 33559 06/80/02 11:40mn P- OW Therma-Tru*FiberClassic/Snxxpth Star In-swing Fibergkws Door Ma;dmum Size Up To 8'4 x 6"S 10 n r 3.00-1 C. X r When attaching Sideffte the above anchofing applies. SEE SEE MM D OLM ETMAIL 110 2- W PM WS 'A r 110 x 314" LA I" La PM WS. WS SEE MOM gt 6- �j #10 x 314' molle. DEMA 'W ;0 ID PM WS DUN—= Wim ottodft the 9h*0 doodbalt PICON to OW abtf SEE NOTE AN pwkno1w wmwe or* book wo 110 x 2* Lg. PFH W& OEML or When attadft the Sh & #0 x 2-1/2" PFW W& deadbalt pWm to ffm artm9d use IS x 2 1/2* 4 PFN WSL Wim otWWng the str" jomb 3r' - skkftp )crmb use 110 x 1 3/4' L9. PFM WS. (2)#B X 2 IZ La. -3. p VIPS (2)#6 X 2 112' L(L PFH WS in SEE SEE DETAIL COASTAL DETAIL C. AL AUAIINUM ASTRAGAL r pErAL *El x X ATTACH ASTRAGOIL IMM DOLT T- STRW Z M"FRAME VRIILL THRU FOR DRILL THRU FOR A M710 BOLT DEEP A 35710 BOLT DM VWUGH FOR A I" ENOUGH FOR A 2* BOLT THRM THROIN L T-� 3, it. ALIJUP" ASTIMMU. COAST& ALUVINW ASITIVOX SEE Wft n0ft IMOLTS AT WX D**NM j7� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ;�A I ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 04-00029254 Date 11/05/04 Property Address . . . . . . 880 BEACH AVE Tenant nbr, name . . . . . . REWORK WIRING FOR KITCHEN Application description . . . ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor - ----- ----- ------------- -------------- ---------- HINES, ROBERT BILL THOMPSON ELECTRIC CO, INC 880 BEACH AVENUE P.O. BOX 330150 ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 246-2271 (904) 249-5601 ----------------- ----- -------- -------------------- -------------------------- Permit ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 70 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/05/05 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 70 . 00 70 . 00 . 00 . 00 PERMrr IS APPROVED ONLY IN ACCORDANCE WrM ALL CrrY OF ATLAN`nC BEACH ORDINANCES AND THE FLORIDA BUILDING C S. Z04. BUILDING OFFICIAL CITY OF ATLANTIC BEACH ELECTAICAL PERMIT APPLICATION Date:. Property Address: '��Zz_/ Owner: 7 7 ,- 7 - - Telephone#: ,5/6 ,:_ / Contractor: BILL TROMPSON ELECTRIC Telephone#: Z��—JOO"- BOX 33015-0--- Contractor Address: P, O� "I-A^12 -A' 3 Fax#: 2-7c — Kn APITIC �M - In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Building: Building Type: El Trailer Service: If other construction is C3 New Residence U Temp. Cl New being done on this budding ;A( Old Q Commercial Q Signs Cl Increase Or site,list the building ��' Permit number: Re-wire Q Addition Sq. Ft. C1 Repair Conductor Size: ANTS: C PPER ALUMINUM RACE Breaker AMPS T VOLT WAY Switch or Existing Service z4�eol RACE Size AMPS ��00 PH W VOLT WAY Feeders: NO. SIZE NO S I NO SIZE Lighting Outlets CONCEALED OPEN Receptacles CONCEALED OPEN 03D AMPS I 100 AMPS Switches Incandescent Fluorescent & M.V. Fixed 0.100 AMPS OVER BELL Appliances TRANSFER. Air H.P.RATING H.P.RATING CEELING KW-IHEAT Conditioning CONT.MOTOR OTHER MOTORS AMPS ]HEAT Motors 0-1 H.P. VOLTAGE PH__+�. OVER I I-LP. PHS UNDER600V I OVER600V Transformers NO. KVA N KVA No.Neon Transf Ea. .§ign Miscellaneous t,�_:Aely Ile Aom'_Iev qz- 800 Seminole Road Atlantiaeach,Florida 32233-5445 Phone:(904)247-5800 Fax: (904)247-5845 http://www.cLadantic-beach.fLus CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 7. INSPECTION PHONE LINE 247-5826 VIM, Application Number . . . . . 04-00029163 Date 10/20/04 Property Address . . . . . . 880 13EACH AVE Tenant nbr, name . . . . . . REROOF Application description . . . ROOF Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 9800 Owner Contractor ------------------------ ------ ----------------- HINES, R013ERT SHORE ROOFING 880 BEACH AVENUE 914 7TH AVENUE SOUTH ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 241-8842 - ------------ ------ ---- ---- ------------------- ------------------------------ Permit . . . . . . ROOF PERMIT Additional desc . . Permit Fee . . . . 120 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 9800 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---- ------ ---------- Permit Fee Total 120 . 00 120 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 120 . 00 120 . 00 . 00 . 00 PERMrr IS APPROVED ONLY IN ACCORDANCE WnH ALL Cn`Y OF ATLAT*MC BEACH ORDINANCES AND THE FLORIDA BUILDINC-rODES. BUILDNM V It-I A I 0C I CITY OF ATLANTIC BEACH ROOFING PERMIT APPLICATION Date: Job Address: s8D ieft�l ;Nve- Owner of Property: iAu Lrlr A- Address: i?-bo ­P�e,/-tct--) Aaq - Wet-cAvc' �("lephone: DD-7 L I State License Number: Contractor: nllbtse �� Contractor's Address: q ILV. Telephone: Fax: ScopeofWork:— (34CK -,<-#r,u Deck Slope: /2- Greater than 2:12 Less than 2:12 Valuation of work: 9 K0�) 0�/ Product Name(Example: Timberline): 6 11-Cle I Manufacturer (Example: GAF): ASTM Designation(s): 0 3161 Required Inspections: Sheathing and Final Signature of Owner: (,�-A Date: Signature of Contractor: Date: 3o - (A AS TO OWNER: Sworn to and subscribed before me this day of oc�nber 20 Stat . . I ' ' ] 'y 0 1�'B U R N S to cg Ro Q 13 142 otary HOL Y OZBURN Notary's Signature: Notary POP.- State of Rwida Is My C, v ion EA�*m Aug 13,2006 Commission X 00142145 Personally known El Produced identification BonckNi�iy National Notary Assn. Type of identification produced AS TO CONTRACTOR: Sworn to and subscribed before me this r? day of 200q State of Florida,County of Duv �jr-)LLY OZBURN Notary's Signature: Notary Pubi�r - State of Florida E,#MA413,20M Personally known my wrr*60C commission 1 DD142i45 Bonded BY Nlibo"NotarY Assn. FlProduced identification Type of identification produced 800 Seminole Road Atlantic Beach,Florida 32233-5445 Page I Telephone: (904)247-5800 Fax: (904)247-5845 -http://www.ei.atlantic-beach.fl.us Revised 2/21/03 5 MTk RETURN Book 12102 Page 2079 p OHONE# M#:21%014ZP5q8j 0 P44e: 2079 Permit number Tax Folio number 111 ad 1 0---rded 10/19/2M 11:30:41 AM JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTY NOTICE OF COMMENCEMENT RECORDING S 5.00 TRUST FUND $ 1.00 REC ADDITIONAL $ 4.00 STATE OF FLORIDA COUNTY OF DUVAL TBE UNDERSIDED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,the following information is provided in this Notice of Commencement. 1. Description of property: W IS-1-4 Lo(C cz-Ou�) uas-a3rL dob Pmiuof- LD± 2. General description of imp tS rOVO4��—Z—V� 3. Owner infonriation: a. J_Adftss: 99D Ra� A& b. Interest in ProPertYj,,,,,, F CCrL c. Name and address of fee simple titleholder(other than owner): 4. Contractor's name and address: &e rly a. Phone number. 04) b. Fax number: q 5. Surety information: a. Name and address: b. Phone number. c, Fax number:_d. Amount of bond: 6. Lender's name and address: a. Phone number: b. Fax number 7. Person within the State of Florida designed by owner upon whom notices or other documents maybe served as provided by 713,12(l)(a), Florida Statues. Name and Address: — a. Phone number. —b. Fax number: 8. In addition to himself/herself,owner designates 0 to receive a copy of the Lienor's Notice as provided in Section 713.12(l)(b), Florida Statutes. 9. Expiration date of Notice of Commencement (the expiration date is one (1) year from the date of Recording unless a different date is specified). Cc: D. Ford CITY OF ATLANTIC BEAC14 <� S, Doerr DEPARTMENT BUILDING / ZONING 800 Seminole Road Atlantic Beach,Florida 32233 (904)247-5800 ------ (904)247-5845 Fax PLAN REVIEW COMMENTS OD Permit Application # Property Address: UACJ; AVENXAV, Applicant- 5wv- Project: 'Rrc� �00F This permit application has been: Approved Reviewed and the follow'"items need t CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET .,Date 6 q -C74 Address 12 Permit fee based on dollar evaluation as indicated on permit application. .Heated Square Footage @ s per sq ft= S Garage/Shed @ S persqft= Carport/Porch @ S persqft= S Deck @ s persqft= Patio @ s persqft= S TOTAL VALUATION: $ S q goo $35.00 is, S1000.00 S $35.00 Total Valuation 5 S t4 Remaining Value Per thousand or portion thereof: CONSTRUCTION TYPE: TOTAL BUILDING FEE S ZONING: + V:z Filing Fee ' 5 Q0 FLOOD ZONE: Fireplaces @$35.00 S INIPERVIOUS SURFACE: BUILDING PERNUT FEE S i2Z WATER L"PACT FEE $ SEWER E"PACT FEE S WATER MMTERITAP $ CAPITAL 1IMPROVEM[ENT S SEWER TAP $ C ( )RADON HRS .0050 S SECTION H PAVING S CROSS CONNECTION S ST ( ) SURCHARGE S OTHER S GRAND TOTAL DUE S \0 CITY OF ATLANTIC BEACH, FLORIDA .A v IT k (Y A e5 ;� APPLICA I TION FOR ELECTRICAL PERM 00/ TO THE CHIEF ELECTRICAL INSPECTOR: DATE:— Ado IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR D G THE WORK AS DESCRIBED IN THE FOLLOWING, WE '101 HEREBY AGREE TO PERFORM SAID WO RI RK IN ACCO.J�CE WITH THE ATTACHED PLANS AND SPECIFICATIONS, TH WHICH ARE A PART HEREOF, AND IN ACCORDANC ITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. ELECTRICAL FIRM: MASTER ECECTRICIANW–NATURE JOURNEYMAN 1� /"RFD—BOX— NAME ZYj2 S ADDRESS: 4:1 BLDG.SIZE BETWEEN: RES._k_ APT.( I COMM.( PUBLIC INDUS. ( I NEW( I OLD( REW.1 ADDITION I ) TRAILER I TEMPA SIGNS ( ) SQ. FT. SERVICE: NEW I INCREASE ( REPAIR,�4– FEE CONRUCTOR SIZE AMPS COPPER ALUM. ( I SWITCH OR BREAKER AMPS PH W VOLT RACEWAY Z*dv EXIST.SERV.SIZE ZeK AMPS PH W 54mO' LT RACEWAY FEEDERS NO. SIZE IND. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RE,ClPTA%ES` CONCEALED- OPEN TOTAL 1 0-30 AMPS, I `S� SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPS. OVER APPLIANCES BELL TRANSF. AIR H.P.RATING H.P.RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT; KW-HEAT 0-1 OVER MOTORS H.P. VOLTAGE PHS NO. I H.P. VOLTAGE PHS m MISC t kNEOUS a 4- �odfloa- lr0AlUQ5:inRUFWq-- I UNDER 600 V. OVER600V. CITY OF 4&aa4c Beacls-49 Office of Building Official REQUEST FOR INSPECTION Date Permit No. --3 Time A.M. Recei—H District No. Owner's Job Adef, s Locality Name-70!��, ContractoA BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing 0 Footing El Rough Wiring Rough C0 Air.Cond.& 0 Re Roofing E Slab 11 Temp Pole 0 Top Out Heating LI ntel D Fire Place 0 Pre Fab READY FOR INSPECTION -MIS M. Mon. Thurs. Friday )e� ue.- A.M. _ /T Inspection Mad t P.M. Inspector A Final Inspection 0 Certificate of Occupancy Date CITY OF 716 OCEAN B0ULEVARr)-0RAV,'ER 25 ATLANTIC BEACH. FL0Rjr)A 32233 eo" Cf_1 BUILDING PERMIQ NO.# ELECTRICAL PERMIT NO.# PLUMBING PERMIT NO.#---- JOB ADDRES CONTRACTOR OWNER DATE REMARKS INSPECTOR FOUNDATION FOOTING SLAB PLL-MBTNG (R) TOP--OUT SEWER TEMPORARY POLE LINTEL/BEAM COLUMN ELECTRICAL (R) PLUMBING (F) FRAMING ELECTRICAL (F) GRADES SHOT CLEARING LOT OTHFR FINAL INSPECTION S, A.m,Es- N ALAN C. JENSEN L_ W. M.INTON. JR. CA T H E P,i'J E G. V A.% 7.E SS C er r7 i 7,er C07,7-n;s-:c,-.er Co.- s e r C 7. S I ef S *IRS _R C.-RL. SILICKI A L L' C'_ A;D E R C K, y A CITY OP -4& Office of Building Of fICIal REQUEST FOR INSPECTION '76 Data-- PermitNo. Time (&W DistrictNo. Rece, P.M, Locality Job r Owner's .4 Contractor 7' Name —61 BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing 0 Footing 0 RoughWiring D---- Rough 0 Air.Cond.& 0 0 Temp Pole 0 Top Out 0 Heating Re Roof Ing 0 Stab Fire Place 0 Add - Lintel 0 Pre Fab READY FOR INSPECTION A.M. 4�� �./t P.M. Mon. Wed. Thurs. Friday A.M. inspection Made P.M. Final inspection 0 inspector certificate of occupancy Date CITY OF Off lea of Building Official REQUEST FOR INSPECTION Date Permit No. Time A.M. Received District No. P Job Address Locality Owner's Name Contractor BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing 0 Footing 0 Rough Wiring 0 Rough 0 Air.Cond.& 0 Re Roofing 0 Slab 0 Temp Pole 0 Top Out 0 Heating Lintel 0 Fire Place 0 Pre Fab READY FOR INSPECIIbK A.M. Mon. Tues. Wed. /'Th-11a,� Friday—P.M. A.M. Inspection Made P.M. -1" Inspector Final Inspection W/ Certificate of Occupancy Date CITY OF ATLANTIC BEACH, FLORIDA ApPrOVW bY A I PPLICATION FOR ILICTRICAL PIRMIT TO THE CHIEF ELECTRICAL INSPECTOR- DATE: IMPORTANT NOTICE: IN CON , , SIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRI ED N THE FOLLOW NG, WE HEREBY AGREE TO PERFORM,SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF,AND IN'ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. aniGNAlrugg JOURIJEXM ELECTRICAL FIRM: 4�8 AERE&C9TRICI- 1- 9!!5_7 90 NAME 4-1; ADDRESS:— /2 z4lze�FD—Box— BLDG.SIZE BETWEEN: RECA-4- APT. COMM. PUBLIC INDUS.I NEW( OLDI I REW. ADDITION I I TRAILERI TEMP.I I SIGNS ( 90.FT. SERVIOEt, 10W I ,I INCREAS04, REPAIR I I FEE Sf-Zg AMPS- COPPER I ALUM.jt>� SWILCH OR,OR t Z PH -3 W 75:4-QOLT RACEWAY L Z.02 AM, 0e. EXIST.SERVI SIZE AA0AM" Z PH 3 6LT R&CEW W AY FEEDERS No.� SIZE IND., SIZE NO. SIZE LIGHTING oul!�IETS CONCEALED OPEN TOTAL R!pgnACLES EALED OPEN TOTAL CONC 41-100 AMPS.�I 0.30 AmPli,��. swircHES 114CANOESCENT, FLUORMENT&M-V.- RXED 2.100 AMW I OVtR I BELL TRANSF. APPUANCES , AIR, H.P.RATIN H.P.RATING, CONDITIONING, �qW.MOTOR OTHER MOTORS AMPS, CEIL HEAT: KW-HEAT 'Al yal 0.1 OVER MOTORS H.P. VOLTAGE PH$ No. 1 H.P. VOLTAGE PHS1 MISCtirLIRrous TRANSFORMERS: IJNDER'600 Vi - OVER 600 V. 4NPORMATfON MANAGMENT SERVICES AM AW - 0 0 P- 0 > 0 0 c- --i W 0 0 m m '0 m z G) 0 m --q > z m m 0 'M m r- z cl) --i > m 0 q "a m cl) m 0 U) 0 m z 0 z c/) 0 0 m m .. ITT m m 0 z 0 0 m z L4 0 m z 0 z (+ c: co 0 P7 0 ED 0 tyj 0 OD z tri 75 0 I Cr z 0 En W m 0 IV 0 V z t7 :z z 0 :x ttl ch C) in 1�4 V— .. z mz > 0 EA) z m 70 z- W 0 m X w > m 'D 0 '0 0 z zm m m m 0 -0 < m r- m m 0 > m c m -0 0 K , D* 0 (n 0 (D R m -n 0 c M z cl) 0 m 0 0 'o (A) 0 Ej K) G) m I m o 4 P7 m z 0 '401* 401b, DEPARTMENT OF BUILOING CITY OF ATLANTIC BEACH LOCATION INTURNATION Address 1 880 REACH AVENUE, 29, ATLANTIC BEACH# FLORIDA 32233 Pertait, Typoi "WELL - VESCRIPTrom cxaow�.aj work-% ALTERATION Sectlool Lot BIcwk Constr* Type 3 N/A, GLS , FANXLY I I 'Plot Book3 Poo&1 0 Proposed U00% ST R 0 ion I C Code 2 0 -------- ---------- OWNER INFOR"ATION us ISO I' HR. �HINES Top't av", cost�jl BEACH AVENUE Fe*ftj Address's 880 Total,, ATLANTIC BEACHO FLORIDA 3223.': $10000 At" Phone 1, (904)241-848'!� -Atop, IRRIGATION PURPOSES ONLY q,� APPLICATION FEES Ac Y PiMk emp $10. 00 f0ox WX+ER IMPACT FEE: $0. 00 , 0 1 _ , kCT PESO SEWeR "Wit. f?ADON 13 AS 5% atoi WATER TAP 4., SEWER TAP vo.-00, HYDkAUL R PECT F ES '40.00 ""00.00, 00 HER OT -14 70 NOTES: NOTICE ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POURING PER M IT VOI D,S I X MO NTH S AFTE R DATE 0 F ISSU E 0,801SH,AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN BUILDING MATERIAL,R PUBLIC SPACE,AND MUST BE r CLEARED UP AND HAULED AWAY�BY EITHER CONTRACTOROR OWNER. , "FAILURE 7 PLY"WITH THE MECHANIC X IN, 10-com S' LIEN LAW CANAESUL OTY,-o r WN"ERPAYING TWICE FORBUILD ING IMPROVEMENTS.95 THEPROPE I I$SUED-ACC' 4G To 4 PP 00 VED,PLANS"WHICH ARE,P I ART OF THI r$ PERMIT AND S UBJECT TO REVOCATION:F6`R ORD0 VISION 6LAtION OPAPPLICABLE PR Of LAW. NGPE RTMENT ATLANTIC BEACH BUILDI U) 0 K 5 m z 0 -1 tZ r OD :I- OD z 0 1-4 -1 Z 1-4 VJ in o in M AZ :bl t7j Irv-, 1 0 a W 0 r H m r -1 0 0 H -1 V to 0 0 H a 0 z z i= o z (A :P� 0 — EO mz > 0 0 EA) 0 M z .0 Z m > -4 0 z > 0 m m -4 0 0 m > z z "U j > 0 m 0 U) '0 0 M C m < 0 > a) M m -0 0 0 r C) cn < > cn 0 W M 'n C) — a :E 4 0 C 0 M z rn M m 7, 0 r :v > to ith 0 CY c 0 0 m 0 0 m C- m 0 > m C) 0 z M F] 0 z LI) Aftk AM FEE $10.00 '-7 AP-MICATION FOR �UL PERMIT CITY OF ATLANTIC WEACH PROPERTY OWNER Day Phone Name: Address t q 6) -t-' Zip _-2 APPLICANT, IF a= T11AN aMR Namt Day Phone,,�� Address,, /-//C Ae �—zip2—LEL'3 JOB Address or Location; Legal Description: Is well to be used for drinkin .g purposes? Any person, individual, corporation or other entity receiving a permit as provided in Section 22-40 of the Atlantic Beach Code, and who plans to use water from the permitted well for drinking purposes, must first obtain a bacteriological test report from the State of Florida Health Deparuielit:, furnishing a certified copy thereof to the building department of the City of Atlantic Beach. A certificate of occupancy will not be issued until said report is an file with the building department. Department Notes: I agree to camly with regulations stated herein: &4mture - f -V Date Aolk Aft > z C/) 0 m 0 0 r- m 'D C- 2 m 0 -1 0 m m m M 0 0 z 0) 0 m 0 4 0 -4 m m 0 rn 0 4 m txl 0 q Im CO 0 a) E0 V 't �-4 b.1 OD PI r) M < CD tri 0 0 P7 R 000502 , DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH PERMIT iflFORMATION ------ LOCATION INFORMATION ---------- Permit Hulnt)er 0 2 Address: .880 BEACH AVE. Fle-cmit Type: ELECIIZICAL, ATLANTIC BEACII, FLORIDA 322:33 Glaso of Work: 114r7REASE LEGAL DESCRIPTION ------- Constr. Type- N/A Lot 3 Blacks Sec.L i0t)I Proposed Use- 91140,L17 FAMILY Plat Books Page: 0 Owelliiqp-�11 0 C d e 0 Subdivision*. EG t i rna ted V Z-t I U o il(). 00 OWNER INFORMATIOtl Improv. cont. IVO. 00 HLR toe Z COALSON CONSTRUCTION 41351. 00 To t a 1 Ffi Addire 880 BEACH AVE. Amount Paid i C§371. 00 ATLANTIC BEACH, Fj6f_,)tRIDAI ;02;,k?p3/ -1 f iz E�*;it 1 '4 Wl I Ph.Inga i r4n4 1'>4r) �,yrn 1 9�, L 7 I� I/ Vhwl, nrzo�it- r-m 4 1 02'Wha tit psa U&mc-i­,,)r1n mp, I W 40")/ 1 �)Qvn If assyst I rlfla tit pry It-,h1w 2 41 / 1 2 cbf,ITRACTOR(S� APPLICATION FEES ---- BILL. THOhPSON ELECTRIC CO, I 14C $35. 00 WATER 1MPAqT FEE: *0. 00 SEWER IMPACT,- FEE R WAT g tIFTE *0. 00 , RADON 6A S-H. R-S., $0. 00 RADON GAS 5% 10. 00 WATER TAP $0. 00 SEWER TAP 'Ito. 00 HYDRAULIC SHARE 110. 00 RE-TUSPECT FEE 140. 00 . ENG114EERING 1$0. 00 OTHER 4Q..00 NOTES: Change service fron 150amps to 200amps, rewire for remodeling NOTICE—ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POURING PERMIT VOID SIX,MONTHS AFTER DATE OF ISSUE , BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS.991 ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. r)-rhA P NT CITY OF ATLANTIC BEACH, FLORIDA Approval by_ PPLICATION FOR ELECTRICAL PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE:— 3; IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH P? TRI!PA Cp%. BILL THOMPSON EL P. 0. BOX 50398 -0,Vq I&MMLLE U.IA011, EL J2249-DM ELECTRICAL FI ROM: WASTER EL:ECTRI61ANSIGNATiRE JOURNEYMAN NAME 61�2- 4�-�ADDRESS:-- RFD—BOX_ BLDG.SIZE BETWEEN: RESJ4 APT.( COMM.( PUBLIC I INDUS.I I NEW( OLD4q REW.I ADDITION ( ) TRAILER ( TEMP.( ) SIGNS ( ) SQ. FT. SERVICE: NEW I ) INCREASE V� REPAIR I FEE CONDUCTOR SIZE '-114 AMPS Z-60C COPPER I ALUM.14 CID SWITCH OR BREAKER 01-57 AMPS PH �W /-rfVOLT RACEWAY 27 c-f 0 EXIST.SERV.SIZE X�60 AMPS PH 7W ;qaVCLT RACEWAY FEEDERS NO. SIZE INO. SIZE I NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 1 0.30 AMPS� 31-100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPS. OVER APPLIANCES BELL TRANSF. AIR H.P. RATING H.P.RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT OVER MOTORS H.P. VOLTAGE PHS NO. I H.P. VOLTAGE PHS MJSCELLANEOUS V 000625 DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH qj[T �1,�Nj'7#r,_ ION LOCATIO N rNFORMAT'rom Pervit Ruolberll� :Addreset 840 BEACH AVRNu P t ATLANTIC 8VACH, 'FLORIDA 3,2233, class ox work i: 'NEW LEGALDESCRIPTION ------- constr. Type�- MIA"'' Block I Section2 Proposed -One I trouLt, FAMILY' Plat sookt -Pago I 0 C4dw,4 Q0 i1vated-valuo I 109j.00, ------- OWNER INFORMATION I*p-rov.,,,cootll-�' *0.00. Nave T Addromms, 880 REACH AVENUE IX, & . QV $46. 00 ATLANTIC BEACH PLORIDA :32233 , Phoxio x ZV'WNT 'INK, X, -2, x 2 - wo CATION PSES OCCA 0, 40, 00 WATER IMPACT Ple-E P. 1"OvOt Ipm Ar , 4000 TL all, *Doc(Tt d ,wo,"'t,ow, we"f,"" RADON 0AS-fj.,ft.,s. 06 %g. RADON GAS kcc� *0. On % WATER TAP *O. oA430 IA UP)/9.1 wo �-w TAP,� 101 HYDRAULIC SHARV *0. OG,L -R lmspktT 'fries �,xl 9,11 1, *6�"00 ENGINEERING 0 v 'a, OTHER", S4 NOTE&, NOTICE ALL CONCRETE FORMS AND FOOTINGS M I UST BE INSPECTED 13EFORE POURI' NG �PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE, BUILDING MATERIAL,RUB81SH AND DEI3R.1S FROM THIS WORK MUST NOT BE PLACED INPUBLIC SPACE,AND MUST BE HAO LED ACTOR,OR OWNER. CLEARED UP AND AWA*�BY EITHER CONTS -T IN "FAIL11149,T0 CO PLYWITH THEMECHANICS' LIEN LAW R9SUL CAN PA THE PROPERTY OwNtA YIN6TWI E FO IMPROVEMENTS. c RIBUILDING IAWEP ACCORD IN 1,0.AP-PROVIED', PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT,TO REVOCATION'FOR �(IOLATI OF ON APPLICABLE'PROVISIONS OF LAW. TLA"i or INO DEPARTME NT VIL BUILDING AND ZONING INSPECTION DIVISION 4** CITY OF ATLANTIC BEACH ATLANTIC BEACH, FLORIDA 32233 APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER IMPORTANT — Applicant to complete all items in sections 1, 11, 111, and IV. Street Address: 191-50 WE- LOCATION .'', OF Intersecting Streets: Between And BUILDING Sub-division 11. IDENTIFICATION — To be completed by all applicants, In consideration of permit given for doing the work as described in the above statement we hereby agree to perform said work in accordance with the attacked plans and specifications which are a part hereof and in accordance with the City of Jacksonville ordinances and standards of good.practice listed therein. Name of Mechanical Contractors Contractor (Print) Qg:�;w SrFNTT1L7 Master Nome of Property Owner Signature, of 0 1 Signature of 'w or Authorized Aq Architect or Engineer GENP 4d A, Type of hosting W: B. IS OTHER CONSTRUCTION BEING 00 WE ON Electric THIS BUILDING OR SITE7 CO) s—[3 LP [3 Natural C) Contrall Utility IF YES, GIVE NUMBER Of CONSTRUCTION 13 Oil PERMIT [3 Other — Specify IV. MICHANICAL IqUIPMINT TO BE INSTALLED NATURE OF WORK (Peovicle complete list of components an back of this forok) Residential or 0 Commercial Host 0 Space 13 Recessed A Contall a PAW El New Building Air CoWifioning: E3 Room X"Pentral , )Czx1sting Building )1(.,Dvcf System: Mstefialbucl—so Thick El Rep lacement of existing system *V Now installation(No system previously installed) Maximum capacity cf.m. #� - El Extension or add-on to existing system 13 Rotrigoraflon C] Cooling tower: Capacity El Other — Specify C3 Fire sprinklers: Numbw of hos�h 0 Elevator 0 Monfift 0 Escoleft THIS SP^(M POIt OFFICA US 014LY 0 6006119 pumps —(number) (R000k") CIr To .(number) Remarks 13 U*confaine (number) 0 UrAred pressure v~ 0, Permit Approvod by. D4106— Othw Specify Permit Wr ALL EQUIPMENT Am coNDmoNiNG AND REFRIGERATION EQUIPMENT C& jpad�y ApPMV%g NUMberUnfts D"Criptift No"Number Manufacturor (TOW "env e_bA)p OA>I-r- 3F&t-ko? C_ IWORMATION MANAGMENT SERVICES A% Ak 4" AO* A*k Am 411� 0 0 0 > 0 M 0 4 0 z CD m m z w m A > m it r- m z 0 m m 0 A 0 > 0 z (P m m z > 'a 0 cn ct) > cn m z 0 C) 5. 0 m m ITT z m m -0 0 --q c 0 m z 0 m co > OD r- z 0 CID < 0 in :Do 0 z H to f+ c M 0 M En :0� w 0 0 r. tn m m a -3 0 G) 17, z 0 z 0 0 c :x W z z W z a) G) t1i w (A) m OEM T m M M > 0 0 Z > I z 0 m 0 m m _0 0 _0 U) -0 0 m rl m c m < 0 > m -0 cn 0 cn cn 0 M 11 < C 0 M z co m W m 0 0 OD m e. M Ln m H W z 0 c: EJ m F] 0 z 111 z G) :1 4m Aft Awk Alk AW CITY OF 4&a4c Beac.4-Qaja- Office of Building Official REQUEST FOR INSPECTION Date Permit No. Time A.M Received ",M, District No. Job Address lity Owner's Name -Contractor BUILDING CONCRETE ELECTRICAL PLUMBING ,,,,�ECHANICAL Framing 0 Footing 0 RoughWiring 0 Rough A r.Cond.& 0 Re Roof!ng 0 Slab D Temp Pole 0 Top Out 0 Heating Lintel 0 Fire Place Pre Fab READY FOR INSPECTION Tues. Wed. Thurs. Friday le I�. M. Inspection Made 641ep M. Inspector Final Inspection 0 Certificate of Occupancy Date UO 000523: DIM FITMENT OF BUILDING TIC BEACH TY OF ATLAN 523 890 Botch Ave. o Atltwtic Botch, Plovida 32233 11W iisti. Vy" N/A Logal Discrivitift ft-%)6*od US# jjjjkslo�4**% Lot: Section: Block. Plat Book Pago 0 80404*d'.vsk i4i 14"Y"O. CosV , Owner Infom�slon NX0 Miles Total Poos: Awsuft,Paid,' useli AVe. Dow palt Atlantic Reach Florida 32233 No In-stall hAne 641-0833 Sj� 11f p �ostidm pow. w to' A# cost 14`6ft ss.so :2912lu- A�f L N CK 0 C rA A ip [ A P Wi ............ NOTES: A MUST BE INSPECTED BEFORE POURING, NOTICE— 'coo �N -ALL K",jTV.OID,.SIX MONTHS AFTER DATE OFISSUE BISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND-MUST BE AY, 'CLEARED UPAND,HAULED�AW B1 ,jiT, 4ErF,4,CONTRACTOR OR OWNER. ITA LURE,TO COM IN T"E �MECHANICS', LIEN, !LAW CAN RESULT � THE PROPERTY10 "Ell Vi FOR BUILDING,tMPROVEMENTS. ISSUED,-ACCORDING TO 400",:VEQ�,PLA4S,WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION OR OF APPLICABLE WwN AT -ANTIC BEACH SUI'LDINd PEPART'' AeNT CITY OF ATLANTIC BEACH APPLICATION' FOR PLUMBING-PERMIT JOB LOCATION- lF-AciA a"(A ±t i-es I od6, PLUMBING CONTRACTOR jj� c, LICENSE NUHBERS CFCO 33e)70 OWNER- BUILDING CONTRACTOR TYPE OF BUILDING slm�s SHOWERS LAVATORY WATER HEATERS BATH TUBS DISHWASHERS URINALS DISPOSALS CLOSETS WASjjTjjC- �,V�CIIINE FLOOR DPAINS OTHER TOTAL FIXTURE COUNT I N SIT'ALLATION OF PLUMBING AND FIXTURES MIUST BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE . CITY OF 4&#dw BeacA-0;&U-4& 6 - office of Building Official REQUEST FOR INSPECTION Date 4651sp 9 Permit No. Time A.M. Receiv District No. Owner's Job A^ess Locality d6t,�ZZs Contractor Name 1-4 BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing 0 Footing RoughWiring D Rough Air.Cond.& 0 Re Roofing El Slab %kK�k--Temp Pole 0 Top Out 0 Heating Lintel Fire Place 0 Pre Fab READY FOR INSPECTION Mon. Tues. Wed. Thurs. A.M. inspection Made P.M. Inspector Final Inspection 0 Certificate of Occupancy Date 000453 _71 DEPARTMENT OF BUILDING jPITY OF ATLANTIC13EACH PeRKIt IhF0*t*r%0 LOCATION INFORMAT Pii�r*it Number'#_ Addremol Permit TY,po SU110 1W, TLANTIC BEACH, FLORIDA 32233 Claaw.01 Vewicli A-00t, 10, ------- 1,96AL DESCRIPTION ---------- �;7 Constr. Type". I;j t Lots 5 1 Blacks Sectlioni, Proposed 'Usei' -01SIOL$ �ftjg%,Lv Plot gooki Page* 0 ngs 1 0 .Dwolli 0:11:,,, Subdivistoni CLUB MANOR ---------- OWNER INFORMATION --------- ' ' sti-mated Valuws� 00-00 *4044*.06 me S I*priov. �c ts'' No 1 000 NINE Total *.41 Addrawai 6000 BEACH AVE. 41 ATLANTIC REACH, 'FLORIDA 32233 oat Phonei 4904)249-3470 , 4 A's PER PLANS 10 V *e ICATIOR PECS ----- v, OCR PET 4,14 *197. 25 WATER IMPACT FEE $140. 00 4 7 t 4 1 OK SEWER I"P'*m� Fee WJ/ ii d'A 06cp :5 �JP W1 RADON IGAT /0 7/ �01 Lj $0. 50 RADON GAS 5% WATER TAP 00.00 SEWER TAP. HYDRAULIC SHARE 00.00 RE-INSPECT FEE *01. 00 9RGINVER1,N0 so. C) OTHER Qland N NOTICE ALL C ON'CRf1.T 6 AND FOOTINGS MUST BE INSPECTED BEFOREPOURING F"ERIMIT VOID SIX MONTHS AFTER DATE OF,ISSUE BUILDING MATER IAL, -ND;DEBAItFAOM THiS WORK MUST.NOT BE PLACED IN PLIOLIU ZWAL;t,AND M I US RURBISHA TBE CLEARED UP AND.HAULED AWAX�:EIIMERCONTRACTOR OR OWNER. `W1 T ' LIEN, LAW CAN' RESULT IN FAILURE70'�:COMPLY H, THEMECHANICS 60EIRTY OW THE PR NERP4YING TWICE FOR BUILDING IMPROVEMENTS., 1" ED,ACCORDING TO APPROV96PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION,FOR ' RQVI _�16_ IOH OF)OPLICAOLtP �,N$ ILAW. ATL T �A I I L 0*N 6 6 EP 4 R TMiN T 4 Address Heated Square Foot'age @ $ S-'Z) per sq ft = $ Garage/Shj,d @ $ per sq ft = $ Carport/Pordi @ $_ ?,e�S er sq ft = $ Deck 9 $ 6 . 9 er sq ft = $ 63 Patio @ $ er sq ft = $ TOTAL VALUATION: $ 0 V2 Total Valuation lst $ ,2 �� // L/ C, 7--2- Reminde-.� Valuation '$7.�;bper thousand or portion thereof -------------------------------------------- Total Building Fee $ 42-1—S-6 ADDITIONAL PERMITS and/or FEES RDQUIRED + k Filing Fee 7S- $ Mechanical Fireplaces @ 15.00 $ Plurbing BUILDING I PERMIT FEE $ Electric/New ------------------------------------------------- Electric/Temp BUILDING PERMIT $ Septic Tank Well WATER METER CHARM $ RAnuling Pool SEWER DAPACT FEE $ Sign WATER ETACT FEE $ Water Connection MISCELLANEOUS $ Pf9dix aao $ Sewer Connection PM-0 Water MRter $ Elevation Certificate GRAND TOTAL DUE $ ---------------------------------------------------------------------------------------------- CALCULATIONS and/or NOTES X 0 T I C E T 0 C 0 N T R A C T 0 R S S C H E D U L E 0 F I N S P E C T 1 0 N S Requests for inspections will be accepted from 8:00 AM until 4:00 PM. All inspections will be made the following day between 8:00 AM and 4:00 PK. SCHEDULE OF INSPECTIONS: 1. Footing 2. Rough Plumbing 3. Slab 4. Framing, Rough Electrical, Mechanical, Top Out Plumbing, Fireplace 5. Final Inspection 6. Certificnte of Occupancy Other inspections may be required in certain situations. Building Card MUST be posted or no inspection will be made. Pour no concrete or cover-up any work until building card is SIGHED by the inspector. You will be required to uncover any work that has not been inspected. In case of failed inspection, $10. 00 re-inspection fee must be paid prior to calling for re-inspection. BUILDING DEPARTMENT CITY OF ATLANTIC BEACH 249-2395 CITY OF ATLANTIC BEACH APPLICATION MR BUILDING PERMIT OwnerISCR 4 )MC— S Address C-t nnr--) APE zip3Z2-tU Phone,7�5 -e��Lq . . ............. _3 � c ��A Architect-40arl) OfLF Address c),Z -TMVI)) S�. �Scf 15 E�PT4_1^jc- �0 K�X e Z3 3 Phone 31 C Ad -3,473 Contractor Eq, - dress TWi&D os7_ sLtl le zi le-T��Phone'z 2 Contractor's License Number C_`I�_CC) Z,7,Z (0 3 Expiration Date_C/ 1 Copy on File ,5 6,� 7 Lo t # Block or Section # Subdivision 0 / ,,��Zoning�_ Street_'_5 Between D(2- side 21:!:t_LVr LLS. rc _1 and__C- V,iltintion Type of Construction W(2t�0F:a_Atynff Purpose of Building Nurber of Units ireplaces V-)C-16, 71 Nt C�) Utility Service: Watert,' SewerL-'- If the City if providing water, .9r,pe ,wer service, do we need to make taps? h�L-) Dimensions: Buildi%_ Lot JJQ) yqo Size Footings C, Sz. Piers Sz. Sills Greatest Span Sills Sz. Ceiling Joists 7-0-Lj,S-S Distance on Centers r1_4[k -Greatest Span__g�- Sz. Floor Joists .+(WS3 Distance an Centers ;1_1qtt Greatest Span -zLq,(_ C_1 Sz. Rafters (_o2,Le-T(LAtS�/-Z_)(b Distance on Centers I(S U Greatest Span C)I-0 ti Method of Hea ing t Solid-Filled Ground Roof Flood Zone If located within a FLOOD HAZARD comPlete page 2 SUBMIT: Two complete sets of plans, including a detailed site plan. D )IF Florida Energy Efficiency Code Sheets Recent Survey 6T,L�l 4P Inspections Required: 1� iAN 3 0 1. M-ien steel is in place and ready to pour foot ings. 2. M-ien steel is in place and ready to pour colums/lintel, 3. When steel is in place and ready to pour bean. Building and Zoning 4. Mien framing, mechanical, plu-nbing, electrical, .fireplace, is completed and ready to cover up. 5. Final inspection. SETBACKS NO INSPECTION WILL BE MADE IF BUILDING CARD IS NOT POSTED ON JOB. In case of rejection, reLnspection MUST be called for after Rear Lot Line corrections are made. In consideration of permit given for doing the work as described in the above statement, we hereby agree Ito perform said work in accordance with the attached plans and specifications, which are a part hereof, and in accordance rt rt with the building regulations of Atlantic Beach. Signature Owner Signature Contractor ron ine FLOODPLAIN DEVELOPMENT INFORMATION Type of Development : New' Building Alterations to Existing Building Flood Zone Required Floor Elevation �Cj 0-Tj j\,j,C-,7 Actual (as built)Lowest Floor Elevation If located within a flood hazard zone (zone A) a survey must be made after the slab has been poured, certifying that the "lowest floor elevation" is equal to or above the base flood elevation established for that zone. No Final Inspection will be made and No Certificate of Occupancy will be issued until the survey is on file with the Building Department . COMMENTS Applicant acknowledgement : I understand that the issuance of this permit is contingent upon the above information being correct and that the plans and supporting data have been or shall be provided as required. I agree to comply with all applicable provisions of Ordinance No . 25-7-11 and all other laws or ordinances effecting the proposed developemnt . Date Applicant ' s Signature ----------------------------------------------------------------------- Department Use Survey filed with the Building Department on Certified Lowest Floor Eleva tion Required Lowest Floor Elevation 4-1 Building Department Representative PLANS REVIEW CHECK LIST 0 w n e r --------------- Legal Description-/J-�I----,------------Contractor---------------------------- 11�Y4 CA-)----------------------License Number-LR��2�u4L,3--------- License on File YES NO Section 24-101 * Zoning EggMIgtions Zoning District Proposed Use __A- JA��-- Required Lot Size /20 Actual Lot Size T-ZIL Setbacks Required Provided .....—S&ction 24-17 INTERIOR LOT front CORNER LOT rear C)-() 2 side-1 Flood Zone---- Required Elevation side-2 Max. Height Allowed Proposed Height Section 24-82 * Minimum Lot Coveragg Required Heated Area ... Proposed Area__I- Section 24-161 * Offstreet Parking Number Spaces Required__,,, .) ... Spaces Provided--c::,)------- Section 24:0? t P2plicate Building@ Is there a similar building within 500' of proposed building?YES (,"NO Utilities Water and sewer service is to be provided by: Buccaneer Utilities ----- City of Atlantic Beach Utilities Private Source SEPTIC TANK WELL Plans Reviewed __Date, Building Permit # --- .......... ('ISSYEP.- ' DENIED City of Atlantic Beach Fixture Unit Worksheet for Water Impact Fee FIXTURE UNITS ARE ESTABLISHED AS THE MEASUREMENT OF WATER DEMAND FOR EACH WATER FIXTURE UNIT INSTALLED AND CONNECTED TO THE CITY WATER SYSTEM. THE WATER SUPPLY CHARGE IS HEREBY FIXED AT TWENTY DOLLARS PER FIXTURE UNIT CONNECTED TO THE CITY WATER SYSTEM. --LBATHROOM GROUP CONSISTING OF -----SERVICE SINK TRAP STAND WATER CLOSET, LAVATORY & BATH (8) TUB OR SHOWER STALL (6) -----WATER CLOSET VALVE -----WATER CLOSET, TANK OPERATED (4) VALVE OPERATED (8) -----BATHTUB/SHOWER (2) URINAL WALL LIP (4) -----SHOWER GROUP PER HEAD (3) FLOOR DRAIN ( 1 ) -----SHOWER STALL DOMESTIC (2) LAUNDRY TRAY (2) --L_-LAVATORY ( 1 ) -----COMBINATION SINK AND TRAY (3) -----WASHING MACHINE (3) -----POT, SCULLERY SINK (4) -----DISHWASHER (2) -----WASH SINK EACH SET OF FAUCETS (2) KITCHEN SINK (2) -----DENTAL LAVATORY ( 1 ) -----KITCHEN SINK WITH WASTE GRINDER (3) -----DENTAL UNIT OR CUSPIDOR ( 1) -----BIDGET (3) -----URINAL STALL, WASHOUT (4) -----FLUSHING RIM SINK (8) -----COMBINATION SINK AND TRAY WITH FOOD DISPOS. (4) -----URINAL, PEDESTAL, SYPHON JET BLOWOUT (6) -----DRINKING FOUNTAIN ( 1/2) -----LAVATORY, BARBER/BEAUTY SHOP (2) -----LAVATORY, SURGEONS (2) -----SURGEONS SINK (3) ICE MAKER ( 1/2) WET BAR (2) TOTAL FIXTURE UNITS---y------ @ $20. 00 EACH $ JOB INFORMATION FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 1000-B-86 SECTION 10—RESIDENTIAL PRESCRIPTIVE COMPLIANCE METHOD CLIMATE ZOPIRS-� Revised: 1/87 DEPARTMENT OF COMMUNITY AFFAIRS NORTHI 2L1j PROJECT NAME — 6�LE: BUILDER: AND ADDRESS: PERMITTING CLIMATE OFFICE: A: ZONE: 0 2 0 3 OWNER: PERMIT JURISDICTION L_ NO.- FFM NO.: NEW CONSTRUCTION IF MULTIFAMILY,NUMBER OF CONDITIONED SQ. GLASS AREA AND TYPE UNITS COVERED By FLOOR AREA I .I I 1 60;FT CLEAR TINT,FILM,SOLAR SCREEN ADDITION THIS SUBMITTAL: FM EAVE OVERHANG SINGLE — SINGLE- so. MULTIFAMILY ATTACHED F_� CHECK IF THIS SUBMITTAL - Ft M So LENGTH FT PANE FT PANE = FT (3 stories or less) REPRESENTS A WORST CASE PORCH OVERHANG DOUBLE- []�SQ. DOUBLE- So. SINGLE-FAMILY DETACHED CONDITION: D l _LENGTH FT _I PANE FT PANE [TM FT_j PERCENTAGE WALL TYPE AND INSULATION CEILING TYPE AND INSULATION FLOOR TYPE AND INSULATION OF GLASS [2T WOOD FRAME MASONRY WOOD TO FLOOR: % EXTERIOR: MASONRY EXTERIOR: UNDER ATTIC: RAISED: RAISED:= R — R= R R - M COMMON: COMMON: COMPLIANCE ADJACENT: ADJACENT. -1� R R PACKAGE R M R COMMON: CHOSEN: COMMON: COMMON: SLAB-ON- R R R= Ll GRADE: R DUCTS COOLING SYSTEM HEATING SYSTEM HOT WATER SYSTEM IN _�ELE�CTRIC SOLAR UNCONDITIONED NONE ELECTRIC STRIP '<'CIENTRAL 1�HEAT PUMP SPACE: R 1:1 ROOM NATURAL GAS OTHER FUELS NATURAL GAS HEAT RECOVERY El PACKAGED TERMINAL ROOM UNIT OR NONE OTHER FUELS DEDICATED HEAT PUMP AIR CONDITIONER PACKAGED TERMINAL IN COND17IONED __F_j HEAT PUMP SPACE: R = F '�� EF SF/EF ELI.11 1 SEER/EER F4 A COP/AFUE NUMBER OF BEDROOMS a In accordance with Section 553.907 F.S.,I hereby certify that the plans Review of the plans and specifications covered by this calculation indicates and specifications cove is c lation are in pliance with the compliance with the Florida Energy Code.Before construction is completed,this C 1�' 3A� Florida Energy cc building will be inspected for I'Ancy in accordance with Section 563.908 F.S. BUILDING OFFICIAL: OWNERIAIT,_ DAT DATE: FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 1000-A-86 SECTION 10 —RESIDENTIAL PRESCRIPTIVE COMPLIANCE METHOD CLIMATE ZON Revised: 1/87 - DEPARTMENT OF COMMUNITY AFFAIRS NORTH 1 2 3 COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAYBE DEMONSTRATED BY USE OF FORM IOOOA-86 FOR SINGLE AND MULTIFAMILY RESIDENCES OF 3 STORIE�S_OR LESS IN HEIGHT,AND ADDITIONS TO EXISTING RESIDENTIAL BUILDINGS.TO COMPLY,A BUILDING MUST MEET OR EXCEED ALL OF THE ENERGY EFFICIENCY PRESCRIPTIVES IN ANY ONE OF THE PRESCRIPTIVE COMPONENT PACKAGES AND COMPLY WITH THE PRESCRIPTIVE MEASURES LISTED IN TABLE 1 OA OF THIS FORM.COMPLIANCE BY THIS METHOD WILL BE,IN WO—ST CASES, EQUIVALENTTOAN EPIOF 100 POINTS Oli-L—ESS.ANALTERNATIVE METHOD IS PROVIDED FOR ADDITIONS OF 600 SOUARE FEETOR LESS BY USEOFFORM 100OC-86.IFA BUILDING DOES NOT COMPLY WITH THIS METHOD,IT MAY STILL COMPLY UNDER SECTION 9 OF THE CODE. PROJECTNAME 151AICaLf—� 7AftNkL_%j BUILDER: AND ADDRESS: PERMITTING CLIMATE OFFICE: ZONE: OWNER: PERMIT JURISDICTION &_ 4 t&) II NO.: NEW CONSTRUCTION Ej IF MULTIFAMILY,NUMBER OF CONDITIONED so. GLASS AREA AND TYPE UNITS COVERED BY FLOOR AREA FT CLEAR TINT,FILM,SOLAR SCREEN ADDITION THIS SUBMITTAL: EAVE OVERHANG SINGLE- SO SINGLE- SO� MULTIFAMILY ATTACHED F� CHECK IF THIS SUBMITTAL LENGTH Ek. FT PANE =FT PANE = FT (3 stories or less) REPRESENTS A WORST CASE PORCH OVERHANG SINGLE-FAMILY DETACHED CONDITION: [I , DOUBLE- []�471SO DOUBLE- so. _ I LENGTH FT PANE FT PANE FT PERCENTAGE WALL TYPE AND INSULATION CEILING TYPE AND INSULATION FLOOR TYPE AND INSULATION OF GLASS WOOD FRAME MASONRY woo MASONRY TO FLOOR: % EXTERIOR: EXTERIOR: UNDER ATTIC: RAISED: Ff_L,7_ RAISED: R = R = R 11 Ell R COMPLIANCE ADJACENT: ADJACENT. R= COMMON: COMMON: PACKAGE A = ME R = .11 COMMON: R R CHOSER COMMON: COMMON: L] SLAB-ON- R R R= [T-1 GRADE: R = M DUCTS COOLING SYSTEM HEATING SYSTEM HOT WATER SYSTEM IN —1 - Wr UNCONDITIONED CENTRAL E NONE ELECTRIC STRIP HEAT PUMP ELECTRIC SOLAR SPACE: R F-1 ROOM NATURAL GAS OTHER FUELS NATURAL GAS HEAT RECOVERY FW �; 0 PACKAGED TERMINAL F-1 ROOM UNIT OR 1:1 NONE El OTHER FUELS DEDICATED HEATPUMP IN COND17IONED AIR CONDITIONER PACKAGED TERMINAL SPACE: R = _T HEAT PUMP EF SF/EF F 4��l SEER/EER = I I I-14�) I COP/AFUE rNUMBER OF BEDROOMS In accordance with Sedion 553.907 F.S.,I hereby.certify that the plans Review of the plans and specifications covered by this calculation indicates and specifications cover lation are compliance with the compliance with the Florida Energy Code.Before construction is completed,this Florida Energy Cod building will be inspected fo�o@o Ii ce accordance with Section 553.908 F.S. OWNER/AGE BUILDING OFFICIAL: ez/) DATE:- DATE: 7TAKLE_1_0`3�' MINIMUM REQUIREMENTS FOR ALL PACKAGES COMPONENTS SECTION REQUIREMENTS CHECK WINDOWS 904.1 MAXIMUM OF 0.5 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK. EXTERIOR&ADJACENT DOORS 904.1 SOLID CORE,WOOD PANEL,INSULATED OR GLASS DOORS ONLY. MAXIMUM OF 0.5 CFM PER SQUARE FOOT OF DOM�EA. INCLUDES SLIDING G SS DOORS. EXTERIOR JOINTS/CRACKS 904.1 TO BE CAULKED,GASKETED,WEATHERSTRIPPED OR OTHERWISE SEALED. SOLE&TOP PLATES 903.2 SOLE PLATES AND PENETRATION$THROUGH TOP PLATES OF EXTERIOR WALLS MUST BE SEALED. INFILTRATION BARRIER 903.2 -INFILTRATION BARRIER MUST BE INSTALLED IN EXTERIOR WALLS&RAISED WOOD FLOORS. INTERIOR JOINTS/CRACKS 903.2 1 ALL OPENINGS IN INTERIOR SURFACES OF CEILINGS AND EXTERIOR WALLS MUST BE SEALED. FIREPLACES 903.2 1 FIREPLACES MUST HAVE FLUE DAMPERS,GLASS DOORS AND OUTSIDE COMBUSTION AIR INTAKES. EXHAUST FANS 903.2 EXHAUST FANS VENTED TO UNCONDITIONED SPACE SHALL HAVE DAMPERS,EXCEPT FOR COMBUSTION DEVICES WITH I INTEGRAL EXHAUST DUCTWORK. COMBUSTION HEATING 903.2 COMBUSTION SPACE AND WATER HEATING SYSTEMS MUST BE PROVIDED WITH OUTSIDE COMBUSTION AIR,EXCEPT FOR DIRECT VENT APPLIANCES, MUST BEAR LABEL INDICATING COMPLIANCE WITH ASHRAE STANDARD 90 OR COMPLY WITH EFFICIENCY AND STANDBY WATER HEATERS 904.2 LOSS REQUIREMENTS. SWITCH OR CLEARLY MARKED CIRCUIT BREAKER(ELECTRIC)OR CUT-OFF(GAS)VALVE MUST BE I PROVIDED. AN EXTERNAL OR BUILT-IN HEAT TRAP MUST BE PROVIDED. SPAS AND HEATED 904.3 SPAS AND HEATED POOLS MUST HAVE COVERS(EXCEPT SOLAR HEATED). NON-COMMERCIAL POOLS MUST HAVE A SWIMMING POOLS — PUMP TIMER. GAS SPA&POOL HEATERS MUST HAVE MINIMUM THERMAL EFFICIENCY OF 75%. INSULATION IS REQUIRED ONLY FOR RECIRCULATING SYSTEMS INCLUDING HEAT RECOVERY UNITS.IN SUC" HOT WATER PIPES 904.4 CASES, PIPING HEAT LOSS SHALL BE LIMITED TO A MAXIMUM OF 17.5 BTUH PER LINEAR FOOT OF PIPE. SHOWER HEADS 904.5 WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE AT 20 to 80 PSIG. HVAC DUCT 903.2 CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS AND LOCAL MECHNfCAL CODE.JOINTS IN UNCONDITIONED CONSTRUCTION 904.6 SPACE SHALL BE SEALED.DUCTS SHALL BE INSULATED TO A MINIMUM OF R-4.2. HVAC CONTROLS 904.7 A SEPARATE,READILY ACCESSIBLE-MANUAL OR AUTOMATIC THERMOSTAT FOR EACH SYSTEM. MAP SHWAJING SURVEY OF LOT 5, , LUB -MWR AS RECORDED IN PLAT BOOK 25 PACE 62 OF THE CURRENT PUBLIC RECORDS OF DWAL COUNTY, FLORIDA. C LU 8 D R I V E 50' R/W (PAV E D) FND. 1/2" L P NO CAP FND. Ile 1.P N. 8 5 0 3 2' 15H E. 5 9.9 NO CAP 0, -CONC. "* ui W DR I.-VE FND. 1/2" 1 P 0 NO CAP 0 2d B.R.L. 0 9.3' 38.0, 0. w 12.0' 1* (4 WOOD 'o w ai z F E N C E li: 4N QD 0 ui w 0 40 Go ui > OD jr OD < w 8' WOOD > w .9 CO T 4 PRIVACY IL FENCE a. CONC*.**.* _w) C) 6. to d3 Z - IL N cy 0- 3: w 0 o o ow ;i 10.2 7.0 —01% ;.0. 1.1, ra 0 cd ow Cki oc.) Rz w U. 2i 32.1' w F N EX In" I.P'11�' S. 850 32 ' 15" W. 60-0 0 �FND. Ile LP No. 1048 (S. 8 50 2 5'14"W. 79.60' MEAL) - NO CAP LOT 7 LO T 6 1) BEARINGS AS PER PLAT 2) S.R.L. AS PER PLAT. 3) THIS IS A BOUNDARY SURVEY. I HEREBY CERTIFY THAT THE PROPERTY­SHQWN HEREON-LI'ES IN FLOOD ZONE "C" AS SHOWN ON THE FLOOD . HAZARD BOUNDARY MAP FOR ATLANTIC BEACH, FLORIDA. T RPPT:.RV rP.PTTPV Tn PnRPPT k vTrVT TJTK7VcZ rwPY K44)DM�_Ar_'V AXTr) %&7PPnCX')T_TrPAr%1 rVTrrrrV ThTCTMARV�V 4&4^&' BeacA-&7&s d* a office of Building Official REQUEST FOR INSPECTION Date Permit No. Time A.M. District No. Received P.M J b Address Locality Own Nam Contractor BUILDING CONCRETE ELECTRICAL PLUMBIJG MECHANICAL Framing Footing Rough Wirin 0 _Bough 0 Air.Cond.& 0 . —9. Re Roofing 0 Slab C p Pole p Out 0 Heating Lintel El Fire Place 0 Pre Fab READY FOR INSPECTION ldch&— u.. Thurs. Friday P--M—N) Mon. Wed. A.M. Inspection Made P.M. Inspector Final Inspection 0 Certificate of Occupancy Date 000501" .......... T C)f: BUILDING TMEN C)r r .9pft CITy of: AITLANTIC LoC,%T;OH INFORMATION 880�­l BEAC14 AVE- ATLANTtC,.' BEACH, FLORIDA 32233 PERHI 'IDESCR I PT ION ------ 14umber t 'AL LEIIJ14,.I . I F I I I. - t., all I permit. L o TYPe' permit Wo r TE11PORARY Lots pages " , plot"- ... ype, Co(.1str. T,U e. SIHGLE NFORIIATION ------ OWHIE I ProP08ec' 0 CC3dq 1 0 so. 00 "':20,00 1)welli"90% '�EACH AVE. L Estimated value, so-00 Add-r L&I D�A 13A22M 3/ . Costs improv- $20. 00 EACH, F. $2 9 4 2 9� 01 �5ul 00 CA .0. 00 4, , Total alle 1 0 d' 0 31 2 13/439 Affiount"p" ' ILI temp. power po e p alutil, obo 60 c)rjt A p w PL I CATI 9 1�', FE �o 00 I-,to�NTRACTOil(s)_, ------- Co' JLHC WATER -JHRACT.�,FEE.,,,:�­" 00 ,.SON ELE FE EWER IMF 1"El i,V xx 4', �_A % IN GAS': RAD( $ Q WATER TAP , p _wER 1A 9F 1110 HYDRAULIC $0. RE-11ISpECT.* FEE, E INEERING $0" NG OTHER NOTES: 4, ALL CONCRETE FORMS AND FOOTINGS MUST BE INS PLECTED BEFORE PDV)3),NG NOTICE PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE� BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BEPLACED;1N PUBLIC SPACE,AND MUST& CLEARED.UP AND HAULED AWAY BY EITH ER CONTRACTOR OR,OWNER.., "FAILURE TO COMPLY WITH THEMECHAN 'r.Vli,E PROPERTY OWNER PAYING ICT LIENIAW .DING, TWICE FORBUILD1 G ISSUED 4N K;CORDING TO APPROVED PL VIOLATION OFAPPLICA91 ANS WHI AR'E pARr MP80 PROVISIONS OF LA W.CH� OF AND 91ja 0 Von A CITY OF ATLANTIC REACH, FLOR E::!7 APPLICATION IFOR LUCTRICAL PLrjjMIr To THE CHIEF ELECTRICAL IWECTOR: DATE: "WORTANT NOTICE: lN CONSIDERATION, GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE "EREBY AGREE TO PERM �'Mll) WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, E IN'ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND C17-Y OF W" PART H REOF�-AM AMCNOTICIEACH ORDINANC BILL I liuM V�0 ��MRIG CU., I W P. 0. BOX 50398 4 Of MC2 5y Lgsoxw BEACH, FL 224 coop 6 -2 c", FIRM: Aim 161A SIGN&WRE JOURNEYMA RFO-13OX EN: -,BETWE NEW OLD( REM lous. Eo,