Loading...
Permit 1291 to 1299 Beach Avenue A f CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ' e ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 02-00025041 Date 10/24/02 Property Address . . . . . 1291 99 BEACH AVE Tenant nbr, name . . . . . . MISC. REPAIRS Application description . . RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning . . . . . . . RESIDENTIAL SINGLE FAMILY Application valuation . . . . 17500 Owner Contractor - ------------------------ ----------------------- HIONEDES, CHRIS VANTAGE CONTRACTING, INC. 1291 BEACH AVENUE 1825-A NORTH THIRD STREET ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 246-6699 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . OUTSIDE WALK, STUDS,TRIM Permit Fee . . . . 120 . 00 Plan Check Fee 60 . 00 Issue Date . . . . Valuation . . . . 17500 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 120 . 00 120 . 00 . 00 . 00 Plan Check Total 60 . 00 60 . 00 . 00 . 00 Grand Total 180 . 00 180 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL OCT 2 2002 City of Atlantic Beach 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 FAX (904)247-5805 • http://www/ci.atlantic-beach.fl.us APPROVED CITY OF ATLANTIC BEACH BUILDING PERMIT APPLICATION BwLDINGpOFFICE FOR SINGLE-FAMILY OR TWO-FAMILY (DUPLEX) CONST .! LOO2 (INCLUDING NEW CONSTRUCTION, REMODEL-, ADDIT S AND ALTERATIONS, MOVING OR DEMOLITION) _ B DATE ®CTD(S62 1, 2(302- JOB ADDRESS /J e4C.11 ye, APPLICANT V/fA!7,4 C E Co NT 'p-A c--ra S N C • V S S cs I �► t-.+ ADDRESS j825,A 0p. 3 rot STi<'C{rT 3 A X. 4EfkG�,[ PHONE: !O4 - 746 - 66-99 '32250 LEGAL DESCRIPTION: BLOCK NUMBER LOT NUMBER I t d'1 ZONING DISTRICT CONTRACTOR -VAtJTA&E r,4 N`t p �r CT o(�S 'JtJ C STATE LICENSE NUMBER 06 C 0 2 2,04 2 ADDRESS 102 'A V�OR-Tk Sd C21 ECT PHONE CITY JAS( • 9E Ik C A_ STATE P L- ZIP 32 2'-S O FAX 90 4 - 246 90'9 9 DESCRIBE PROPOSED USE AND WORK TO BE DONE PRESENT USE OF LAND OR BUILDING(S) ,5 f ei1 c t r VALUATION OF PROPOSED CONSTRUCTION Ai- , ,o, Lt J Is this an addition? 710 If yes,what are the dimensions of the added space:'w. feet byA/0/ feet Will the added area be heated and cooled? � 0 New electrical or increase in service? /V 0�� // New plumbing fixtures? 0 New fireplace? &10 New heating/air conditioning? /J0 Is approval or Homeowner's Association or other private entity required? If yes,please sub nit with this application. WILL THIS PROJECT INVOLVE CHANGES IN ELEVATION, SITE GRADE OR ANY USE OF FILL MATERIAL? [YNO._Applicant certifies that no change in site grade or fill material will be used on this project. ❑YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. PROCEDURE: (In order to expedite issuance of permits, please follow all steps and provide all information as appropriate.) STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information,please contact the Planning and Zoning Department at 904-247-5817. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 6/18/02 STEP 3: Please submit Energy Code Forms,Notice of Commencement,Owner/Contractor Affidavit if owner is contractor,and four(4)complete sets of construction plans to the Building Department, which is located at the Atlantic Beach City Hall, 800 Seminole Road, Atlantic . Beach,FL 32233 Telephone:(904)247-5826 01 In addition to construction and engineering detail, plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures,temporary and permanent, including setbacks,building height,number of stories and square footage. Identify any existing structures and uses. 3. Existing and/or proposed driveways. 4. If required by the Department of Public Works,a pre-construction topographical survey. S. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 6. Impervious Surface area calculations. (Swimming pools may be excluded from total Impervious Surface.) 7. Other information as may be appropriate for individual applications. I HEREBY CERTIFY THAT ALL RM O RONITED THIS APPLICATION IS CORRECT. SIGNATURE OF OWNER \ DATE ��GY I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND. CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH, WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL,STATE OR LOCAL RULES, REGULATIONS,ORDINANCES,OR LAWS IN ANY MANNER,INCLUDING THE GOVERNING OF CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION OF THE PROPERTY. I UNDERSTAND THAT THE ISSUANCE OF THIS PERMIT IS CONTINGENT UPON THE ABOVE INFORMATION. BEING TRUE AND CORRECT AND THAT THE PLANS AND SUPPORTING DATA HAVE BEEN OR SHALL BE PROVIDED AS REQUIRED. SIGNATURE OF CONTRACTOR f` ' _ ` / DATE J� l7- OD- ADDRESS AND CONTACT INFORMATION OF PERSON TO RECEIVE ALL CORRESPONDENCE REGARDING THIS APPLICATION (PLEASE PRINT) NAMEVOin:ffigenY C+ysc MAILING ADDRESS 1'61\)C � �`�-S Y' 4V ,S+r .. 3adC-S 1,l_ PIXA011 PHONE o� ' l S2 `1 FAX E-MAIL SWORN AND SUBSCRIBED BEFORE ME THIS DAY OF STATE OF FLORIDA,COUNTY OF DUVAL NOTARY'S SIGNATURE -AA, AS TO OWNER: Mary F.Farwell ® Personally known =4.. MY COMMISSION DD046789 EX IC S Produced identification *: July 31,2005 Type of identification produced ,a of BONDEDTHRUTROY FAIN INSURANC14INC AS TO CONTRACTOR: Personally known Produced identification (, Type of identification produced ..4,, Cary A.Brown 6!18/02 ' >� '+k= NiY COMMISSION IM CC994917 EXPIRES 7anuary 21,2005 a0NDEDTHRUTROVFAININSURANCE,INC , NEW IMPERVIOUS SURFACE REGULATIONS On January 01, 2002, the City of Atlantic Beach enacted new regulations limiting the amount of Impervious Surface that can be developed on property. Within all residential Zoning Districts, the maximum amount , of Impervious Surface area allowed is fifty percent (50%). Within all commercial and industrial Zoning Districts, the maximum amount of Impervious Surface area allowed is seventy percent (70%). The Zoning regulations define Impervious Surface as follows: Impervious Surface shall mean those surfaces that prevent the entry of water into the soil. Common Impervious Surfaces include, but are not limited to, rooftops, sidewalks, patio areas, driveways, parking Lots, and other surfaces made of concrete, asphalt, brick, plastic, or any surfacing material with a base or lining of an impervious material. Wood decking elevated two or more inches above grade shall not be considered impervious provided that the ground surface beneath the decking is not impervious. Pervious areas _ beneath roof or balcony overhangs that are subject to inundation by stormwater and which allow the percolation of that stormwater shall not be considered impervious areas. Swimming pools shall not be considered as Impervious Surfaces because of their ability to retain additional rain water, however, - decking around a pool may be considered .impervious depending upon materials used. Information verif)jng Impervious Surface must be provided prior to issuance of Building Permits whenever new construction_, including building renovations or additions, new driveways, decks or porches involves any increase in Impervious Surface area. FLOODPLAIN DEVELOPMENT INFORMATION Location:: Type of Development: Flood Zone: Required Lowest Floor Elevation: If building is located within a flood hazard zone, a survey must be made AFTER THE SLAB HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above the base flood elevation established for that zone. No final inspection will be made and no certificate of occupancy will be issued until the survey is on file with the Building Department. COMMENTS: Applicant Acknowledgment: I understand that the issuance of this permit is contingent upon the above information being correct and that the plans and supporting data have been or shall be provided as required. I agree to comply with all applicable provisions of Ordinance No. 25-7-11 and all other laws or ordinances affecting the proposed development. Date Applicant's Signature Department Use: Required Lowest Floor Elevation As Built Lowest Floor Elevation Survey Filed with Building Department Building Department Representative 6 SCHEDULED INSPECTIONS Requests for inspection are taken from 13:00 a.m. unti":30 natLlnspections are made the following working day; please specify a.m. or p.m. Inspection. When catling to an inspection please have the permit nutllber, job location and type of Inspection needed. Inspections are scheduled as follows: 1. Footing 2. Under slab plumbing/sewer/electric 3. Slab 4. Cover up (framing, rough electrical, mechanical, 1lu111bing call for cover-up on building, use building permit number and reference other applicable permit numbers (electrical, Plumbing, mechanical and building, etc.) 5. insulation 6. Final Inspection 7. Drainage Inspection B. Finish Floor elevation survey/Certificate of Occupancy BUMNG CARD MUST BE POSTED OR NO INSPECTIONS VVLL BE MADE Concrete cannot be poured and work cannot be covered up until building card is SiGNED by the inspector. You may be required to uncover any work that Inas not been inspected. It is the responsibility of the BUILDER/CONTRACTOR to Post the building card. A fee of $15.00 is charged for all reinspections. NOTE: This application may be subject to covenants and restrictions for the permitted property. The enforcement of the covenants and restrictions are the responsibility of the homeowners association. - c,9 ..c'7 Citi. ,�y,,,, �. ' . Q, Brook 1.0725 Pages 279 NOTICE OF COMMENCEMENT (PREPARE IN DUPLICATE) Permit No. Tax Folio No. State of County of To whom it may concern; The undersigned hereby Informs you that Improvements will be made to certain real property, and In accordance with Section 713 of the Florida Statutes, the following Information Is stated In this NOTICE OF COMMENCEMENT. Legal description of property being improved: Lots 11 and 12, Block 51, Atlantic Beach aka 1291 and 1299 Beach'.Avenue, Atlantic Beach, FL 32233 Address of property being improved: 1299 Beach Avenue, Atlantic Beach, FL General description of improvements: ✓ d +t G1✓' A4 t r Owner Chris Hionides Address c/o Petra Management, Inc. , P. 0. Box 330448; Atlantic Beach, FL 32233 Owner's interest in site of the improvement Fee- Simple Fee Simple Titleholder (if other than owner) Name Address d � Contractor Vantage- Contractors, Inca Address 1825—A North Third Street, Jacksonville Beach, FL 32250 Phone No. 246-6699 Fax No. 246-8899 Surety(if any) .� Address Amount of bond $ Phone No. Fax No. 1 Name and address of any person making a loan for the construction of the improvements. Name '- Address Phone No. Fax No. Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name Mary F. Farwell, Petra Management, Inc. Address P. 0. Bo: 330448., Atlantic Beach, FL 32233 Phone No. _ 241-1151 Fax No. 24'1-0678 In addition to himself, owner designates the following person to receive a copy of the Lienors Notice as provided in. Section 713.06 (2) (b), Florida Statutes, (Fill in at Owner's option). Name Address Phone No. Fax No, Expiration date o(;Notice of Commencement (the expiration date is one (1) year from the date of recording unless a different date is specified): _ U v� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD Yt' N ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 04-00028449 Date 6/09/04 Property Address . . . . . . 1291 99 BEACH AVE Tenant nbr, name . . . . . . SAFETY INSPECTION Application description . . . ELECTRIC ONLY Property Zoning . . . . . . . RESIDENTIAL SINGLE FAMILY Application valuation . . . . 0 Owner Contractor ------------------------ ------- ----------------- PETRA MANAGEMENT PERRY ELECTRICAL SERVICES 1291 BEACH AVENUE 391 THIRD AVENUE SOUTH ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 246-1588 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . 150AMP, 1PH, 3W, 240V Permit Fee . . . . 70 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ----- ----- ---------- ---------- ---------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 70 . 00 70 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CO ( - qvo,� BUILDING OFFICIAL `l- r. CITY OF ATLANTIC BEACH ELECTRICAL PERMIT APPLICATION Date: ❑'1 Property Address: x 2°l C-%4 y G. Owner: �'e t 2--A. Telephone#• Contractor: 0'�� Telephone#: 2 L G 1 S Contractor Address: IA t 3P-&_oo) -S:, Tvkc.Ks-"(Lu 6-14 Ott Fax#: 24 u Ss Z Z In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of gDod practice listed therein. Building: Building Type: (3 Trailer Service: if other construction is ❑ New K Residence ❑ Temp. ❑ New being done on this building Or site,list the building Old 13 Commercial 13 Signs 13 Increase Pamit number. ❑ Re-wire ❑ Addition Sq.Ft. ❑ Repair Conductor Size: AMPS: COPPER ALUMINUM Switch or RACE Breaker AMPS PH W VOLT WAY Existing Service RACE Size AMPS PH W 3 VOLT Z-t{O WAY *)u Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED OPEN Receptacles CONCEALED OPEN n 10 AMPS i i inn AWN Switches Incandescent Fluorescent & M.V. Fixed 0.160 AMPS OVER BELL Appliances TRANSFER Air H.P.RATING H.P.RATING CEILING KW-HEAT Conditioning COMP.MOTOR OTHER MOTORS AMPS HEAT Motors 0-1 H.P. VOLTAGE PH NO. OVER 1 H.P. PHS k6OOV mg6mv Transformers NO. KVA NO. KVA No.Neon_Transf. Ea. Sign Miscellaneous �-A Y-1%E7T'-91_.-` Z(U "16 800 Seminole Road•Atlantic Beach,Florida 32233-5445 Phone:(904)247-5800• Fax: (904)247-5845• http://www.cL2d2ntic-beach.lLus -- --, =JJp n i v i ns Electric Companu 9042490336 p.2 ,N BIVINS ELECTRIC 1004 SOUTH 2ND ST. JACKSONVILLE BCH;FL 32250 904-249-4308 904-249-0336 FAX January 22,2004 ALL CITIES AND COUNTIES STATE OF FLORIDA RE:PERRY ELECTRICAL SERVICES PERMITS To Whom it May Concern, i This letter is to inform you that Larry Carey of Perry Elect .al Services am allowed to Pull permits under li;,. #ECA-0002917,Raymond Bivins u I Bivins Electric Co.,Inc.is Perry's qualifying agent.Perry Electric have there oven ins, -ance information. If there are ons please our office @ 904--249-M. . Thank yam, "W14 Diving- ext 4 i Tins Ell x*ic Co.,Inc, State of Florida County of T)Uy The foreg ' �Wstrun�xW �kn�owledg�edbefore me thg: LIDdayof who is pots.i gaily known by me,or produced as identification. Signa;.re of Notary Public _ WOOMMSSION# t) MW pokes Now- starnp4kW. MMMU ,sMMOMM ub ZU04 WED 14;57 FAX �OOi/002 ACORD CERTIFICATE OF LIABILITY INSURANCE �� ) 0004 PRooucoe THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION EmployerSoladons,LLC ONLY AND CONFERS NO R004TS UPON THE CERTIFICATE 1800 Secand SAmt,Ste 755 HOLDER- THIS CERTIFICATE DOES NOT AMEND, EXTEND OR SatTu^FL 34236 ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE NAC 0 INSURED INSURER Westpott insurance Company Perry Electrical Services,Inc 3913rd Ave USURER B: JackwnVAle Beach,FL 32250 "SURER e: COVERAGES "SURER E: THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT Tq WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED By THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INBR AtscrtPOLICY EFFECTN! POIJCr EYPIRATTON LatuffaltawaPQLICY NUMBlR LIMITS GENERAL_LASg1TY EACH OCCURRrINGE GQMMERCIAL GEN$ M fTY DwMAOE TO RENTED anccurpgp. CLAIMS MADE OCCUR ono rwn PERSONAL a ACV N TE Y AG MEGATR LMNIT AF LIES PER -COMPIOP AGO 1.71 1 PRD AUTOMDgILE LIABILITY ANYAUTO co 5"GI.a LIMrr s ALL vW"ED AUTOS BODILY INJURY SCHEDULED AUTOS IPerpumn) S HIRED AUTOS BODILY".IURr a NO"40WNEO AUTOS (Per 6"IdsnIj PROPERTY DAMAGE f (PAT 0000 l)) GARAGE IOABILRY p ANY AUTO O'MER THAN EA ACG AUTO ONLY: EXCESSIUMBRELIABILITY EACH OCCUR CLAIMS MADE OCDUC71BLE RETENTION WORKERS COMPENSATION AND X I TAC."-,71.09 OTN. EMPLOYERS'LLPARM >t�00Q ANY PROPRIETORIPARTNERIEXECurnE W00019638 07/!1)!003 07)25!2004 l=NT OFflCE. OCR EXCLLIDED7. EASE•EA EMPLOYE I00,M M dosAA6o urger El DISEASE-Poticy Limrr 1 500400 OTHER DESCRIPTION OF OPERATIONS!LOCATIONS!VENICLTS I EXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVrWNs Fax:9oe Z47-sa4s CERTIFICATE HOLDER CANCELLATION SHOULD AMI OFTNE ABOVE DESCRIBED POLIOU BE CANCELLED BEFORETNE"PIRATION Lary Of Atlas&Beach DATE TNEREOF,THE ISSUING INSURIR ENDEAVOR To MAL 30 DAYS WRITTEN 800 Seminole lid NOTICE TO THE CERTIPICATE HOLDER 0 TO THE LEFT,BUT P RE TO b0 SO BNALL IMPOSE NO OGLI"'"ON OR LAAMU Y F ANY KIND U I ER,Tf8 AOENTS OR Atlam,dc,geaclt,FL 32233 REPRESENTarnEs. Ar AUTNORAIND REPRESENTA ACORD 25(2001108) ®ACORD CORPORATION 1888 PERMIT WORKSHEET Certificate of Occupancy Job Address: Type Work: I'll?I - 1 z`)`1 t�ar'c c_�� l=1✓� fZ ala-)► Property Owner: Phone # Contractor: Phone # / Permit C a 11 Date Issued: Building Inspections: Footing �s�L!ki'1%�-u ��✓rl ��_���2�q Slab 1 Tie Beam BMER®JOE SOM"JOE F+��I w�ndou,:s: Ia,►a- c3 Lintel Nailing / Sheathing 1-2 Framing ! Cover Up ,i5 .G: ��r - :� - �_� �.;A7 Insulation Final Building r'41y J Tree Permit# YES NO Electrical Permit# ,o Temp, Pole Permit# CA Temp. Power Letter Received: YES NO Inspections: Rough Electric Temp. Power fix. Temp. Pole ' Final Mechanical Permit# a U� Inspections: Rough y Plumbing Permit# Inspections: Rough / Underslab x Water/Sewer L Drainage Inspection: Pool Permit# ` x S _K' 'S � �_' k Inspections: Steel ' Grounding Final Roofing Permit# Inspections: Nailing J Sheathing Final Fire Inspection: Failed Inspections: Date Paid: Date Paid: 41 w fr CITY OF ATLANTIC BEACH ;4 800 SEMINOLE ROAD y ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 02-00025329 Date 12/30/02 Property Address . . . . . . 1291 99 BEACH AVE Tenant nbr, name . . . . . . REPAIR AND REPLACE Application description . . . FOUNDATION ONLY Property Zoning . . . . . . . RESIDENTIAL SINGLE FAMILY Application valuation . . . . 7000 Owner Contractor ------------------------ ------------------------ HIONIDES, CHRIS VANTAGE CONTRACTING, INC. 2275 ATLANTIC BLVD 1825-A NORTH THIRD STREET ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 241-1501 (904) 246-6699 ---------------------------------------------------------------------------- Permit . . . . FOUNDATION ONLY Additional desc . . Permit Fee . . . . 65 . 00 Plan Check Fee 38 . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ------- -- ---------- ---------- Permit Fee Total 65 . 00 65 . 00 . 00 . 00 Plan Check Total 38 . 00 38 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Address / y/ ,c Ac �fiy — ��i.:C'4'Tp .Date /,l = �2- 3 v 2 Heated Square Footage @ $ per sq ft= $ Garage/ Shed @ $ per sq ft= $ L Carport/Porch v@ $ per sq ft= $ Deck vrjL` , @ $ per sq ft= $ Patio @ $ per sq ft= $ TOTAL VALUATION: $ d O Total aluatign lst $ v Remaining Value $j.per thousand or portion thereof CONSTRUCTION TYPE: TOTAL BVALDING FEE $ ZONING: + %2 Filing Fee $ 3 x FLOOD ZONE: ( ) Fireplaces @ $15.00 $ IMPERVIOUS SURFACE: BUILDING PERMIT FEE $ 163 , 6 6 WATER IMPACT FEE $ -, SEWER IMPACT FEE $ WATER METER/TAP $ CAPITAL IMPROVEMENT$ SEWER TAP $ C ( ) RADON �iIQ50050 $ SECTION H PAVING ( ) $ HYDRAULIC SHARES $ CROSS CONNECTION $ ST( ) SURCHARGE $ OTHER $ GRAND TOTAL DUE: $ 0C) DEC 18 2002 BY: City of Atlantic Beach• 800 Seminole Road - Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 • FAX (904)247-5805• http://www/ci.atlantic-beach.R.us PERMIT APPLICATION FOR REMODEL, ADDITIONS AND ALTERATIONS, MOVING OR DEMOLITION OF SINGLE-FAMILY OR TWO-FAMILY (DUPLEX CONSTRUCTION DATE 17, • IIP •b2 APPLICANT l/I' yz -H ADDRESS Z21PHONE: •241• lr?ct ADDRESS WHERE WORK IS TO BE PERFO LEGAL DESCRIPTION: BLOCK NUMBERf-A _ LOT NUMBER ?i ZONING DISTRICT CONTRACTOR Yr At�g -� USG_ STATE LICENSE NUMBER ADDRESS _ lb2a A- t�• ' -. PHONE -*44460-46V CITY J Ax • W't • STATE ( ZIP ��C> FAX 4W • r2#449 DESCRIBE PROPOSED USE AND WORK TO BE DONE 1 ►'[f�L.t"i i�l' AILLD PRESENT USE OF LAND OR BUILDING(S) VALUATION OF PROPOSED CONSTRUCTION Is this an addition? If yes, what are the dimensions of the added space: feet by feet Will the added area be heated and cooled? New electrical or increase in service? Ne> New plumbing fixtures? NC> New fireplace? N(.a New heating/air conditioning? Nd Is approval or Homeowner's Association or other private entity required? If yes,please submit with this application. t,,j b f�,U,�­ /U/yy4Y-­1� F,/,a , 4,,,_jrrAe, CaA1 PROCEDURE: (In order to expedite issuance of permits, please follow all steps and provide all information as appropriate.) .STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information,please contact the Planning and Zoning Department at 904-247-5817. In order to correctly verify zoning designation,please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey is required. (If not required, written verification must be provided with this application.). The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone: (904)247-5834 STEP 3. Please submit Energy Code Forms, Notice of Commencement, Owner/Contractor Affidavit if owner is contractor, and four(4) complete sets of construction plans to the Building Department, which is located at the Atlantic Beach City HaIL 800 Seminole Road,Atlantic Beach,FL 32233 Telephone:(904)247-5826 1/02/02 Ln addition to construction and engineering detail, plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures, temporary and permanent, including setbacks, building height, number of stories and square footage. Identify any existing structures and uses. 3. Existing and/or proposed driveways. 4. If required by the Department of Public Works,a pre-construction topographical survey. 5. Any significant environmental features, including any jurisdictional wetlands, CCCL,natural water bodies. 6. Impervious Surface area calculations. (Swimming pools may be excluded from total Impervious Surface.) 7. Other information as may be appropriate for individual applications. I HEREBY CERTIFY THAT ALL FO TION PROVM WITH THIS APPLICATION IS CORRECT. X SIGNATURE OF OWNER DATE 1214 I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED . WITH, WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL,STATE OR LOCAL RULES, REGULATIONS,ORDINANCES,OR LAWS IN ANY MANNER,INCLUDING THE GOVERNING OF CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION OF THE PROPERTY. I UNDERSTAND THAT THE ISSUANCE OF THIS PERMIT IS CONTINGENT UPON THE ABOVE INFORMATION BEING TRUE AND CORRECT AND THAT THE PLANS AND SUPPORTING DATA HAVE BEEN OR SHALL BE PROVIDED AS REQUIRED. SIGNATURE OF CONTRACTO / DATE R ADDRESS AND CONTACT INFORMATION OF PERSON TO RECEIVE ALL CORRESPONDENCE REGARDING THIS APPLICATION (PLEASE PRINT) NAME _WrJN'I' MAILING ADDRESS A. K. ? ''�' .,G • JW_ V 1 UX,: _t W-_EL. 32262n PHONE FAx. _42 •660q E-MAIL SWORN AND SUBSCRIBED BEFORE ME THIS 1 DAY OFt 4,0_(2- STATE OF FLORIDA,COUNTY OF DUVAL NOTARY'S SIGNATURE AS TO OWNER: p4 known Produced identification lei Cary A Brown Type of identification produced s Y MY COMMISSION# CC994917 EXPIRES 7anuary 21,2005 BONDED THRU TROY FAIN INSURANCE,INC AS TO CONTRACTOR: Personally known ❑ Produced identification "•, Cary A Brown Type of identification produced 0'av',�:A r: :i? MY COMMISSION 41 CC994917 EXPIRES �!i` January 21,2005 l/O2J02 BONDED THRUTROY FAIN INSURANCE,INC 1 1,ALT CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 32233-5445 w" / TELEPHONE: (904)247-5800 FAX: (904)247-5805 SUNCOM: 852-5800 ry http://ci.atlantic-beach.fl.us PLAN REVIEW COMMENTS Permit Application # �,r-5 3 7 Applicant: Address: f 2 'fit Project: =104 '' C C ( S T-0 L,ryA aS Your application is approved o Your permit application has been reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed by Signed - Date/Z,�'�2- Contractor Contractor Notified Date CITY OF ATLANTIC BEACH } z3 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 32233-5445 TELEPHONE:(904)247-5800 SI FAX:(904)247-5805 =+ SUNCOM:852-5800 http://ci.atiantic-beach.fl.us Js31 PLAN aVIEW COMMENTS Permit Application # Applicant: ` C Address: 2.9 - Project: o Your application is approved a Your permit application has been reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed by Signed Date Contractor Notified Date CITY OF ATLANTIC BEACH 800 SENUNOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03 -00027043 Date 10/08/03 Property Address . . . . . . 1291 99 BEACH AVE Tenant nbr, name . . . . . . 5 FIXTURES Application description . . . PLUMBING ONLY Property Zoning . . . . . . . RESIDENTIAL SINGLE FAMILY Application valuation . . . . 0 Owner Contractor -------------------- ---- - - -- --- - --- - --------- --- MANA, PETRA STYLES SMITH PLUMBING 1291 BEACH AVENUE 1537 PENMAN ROAD ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (9 04) 241-4131 ------ --- ---- ------- --------- --------- Permit PLUMBING PERMIT Additional desc . . Permit Fee . . . . 70 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due - ------------ ---------- ---------- - --------- ---------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 70 . 00 70 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. s- BUILDING OFFICIAL CITY OF ATLANTIC BEACH APPLICATION FOR PLUMBING PERMIT JOB LOCATION: } Q 9 1 n OWNER OF PROPERTY:_ `'y /�, v\ - TEL. PLUMBING CONTRACTOR: -� U (3 CONTRACTOR'S ADDRESS:_I s 1E�n r►1 r� C STATE LICENSE NUMBER: C U '4 g b _TEL. .Z 3) HOW MANY OF THE FOLLOWING FIXTURES RE-PIPED OR NEW SINKS SHOWERS 2-- LAVATORY WATER HEATERS BATH TUBS DISHWASHERS URINALS DISPOSALS CLOSETS WASHING MACHINE FLOOR DRAINS SHOWER PANS SEWER WATER RE-PIPE(LIST FIXTURES BEING REPIPED) OTHER TOTAL FIXTURES: S X$7.00 +$35.00= MINIMUM PERMIT FEE: $35.00 SIGNATURE OF OWNER: SIGNATURE OF CONTRACTOR: /f INSTALLATION OF PLUMBING AND FIXTURES MUST BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE. CALL A DAY AHEAD TO SCHEDULE INSPECTIONS -(904) 247-5826. ° 1 CITY OF ATLANTIC BEACH ,J J 800 SEMINOLE ROAD .� j � ATLANTIC BEACH, FLORIDA 32233 n INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00026676 Date 8/15/03 Property Address . . . . . 1291 99 BEACH AVE Tenant nbr, name 150AMP, 1PH, 3W, 240V, REWIRE Application description . . . ELECTRIC ONLY Property Zoning . . . . . . . RESIDENTIAL SINGLE FAMILY Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ HIONIDES, CHRIS DAVID T. COOK 1291 BEACH AVENUE 1200 BIG TREE ROAD ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 249-0967 --------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 x k BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL it :t� ✓�, CITY OF ATLANTIC BEACH, FLORIDA ELECTRICAL PERMIT APPLICATION TO THE CHIEF ELECTRICAL INSPECTOR: DATE: ,�f 200— IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. ELECTRICAL CONTRACTOR: MASTER ELECTRICIANS SIGNATURE: G �-� w4p OWNER OF PROPERTY: JOB ADDRESS: RES.( APT.( ) COMM.( ) PUBLIC( ) INDUS.( ) NEW( ) OLD( ) REW.( ) ADDITION( ) TRAILER( ) TEMP.( ) SIGNS( } SQ. FT. SERVICE: NEW( ) INCREASE( REPAIR( CONDUCTOR SIZE AMPS: COPPER( ) ALUM.(L- � FEES SWITCH OR BREAKER AMPS PH W °?VOL RAC WAY ��L 3,� EXIST. SERV. SIZE vV AMPS / PH W VOLT RACEWAY FEEDERS NO. SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS 4-J CONCEALED OPEN TOTAL RECEPTACLES 0 0 CONCEALED OPEN TOTAL 0.30AMPS 31.100 AMPS SWITCHES INCANDESCENT FLOURESCENT&M.V. FIXED 0.100 AMPS. OVER APPLIANCES 161 1 BELL TRANSF. AIR H.P.RATING H.P. RATINGCEIL. KW-HEAT CONDITIONING COMP.MOTOR OTHER MOTORS AMPS HEAT 0-1 OVER MOTORS H.P. VOLTAGE PHS NO. I H.P. VOLTAGE PHS MISCELLANEOUS UNDER 600V OVER 600V TRANSFORMERS: NO. IKVA NO. IKVA NO.NEON TRANSF. NO I VA I MA I MOTOR SIZE I SWITCH I FLASHERS EACH SIGN 800 Seminole Road•Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800. Fax: (904)247-5845• http://www.ci.atiantic-beach.fl.us ReviRM M/17iO3 j zjAj J,. pri�'� CITY OF ATL 4s� ANTIC BEACH j 800 SEMINOLE ROAD J ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00026653 Date 8/11/03 Property Address . . . . . . 1291 99 BEACH AVE Tenant nbr, name . . . . . . HVAC Application description . . . MECHANICAL ONLY Property Zoning . . . . . . . RESIDENTIAL SINGLE FAMILY Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ HIONEDIS, CHRIS A COMFORTABLE ENVIRONMENTAL 1291 BEACH AVENUE 250 WINTER SPRINGS WAY ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32225 -------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc Permit Fee . . . . 71 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 71 . 00 71 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 71 . 00 71 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. BUILDING OFFICIAL CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD j ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 03-00026481 Date 7/22/03 Property Address . . . . . . 1291 99 BEACH AVE Tenant nbr, name . . . . . . REPLACE WINDOWS Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning . . . . . . . RESIDENTIAL SINGLE FAMILY Application valuation . . . 7500 Owner Contractor ------------------------ ------------------------ HIONIDES, CHRIS VANTAGE CONTRACTING, INC. 1291 BEACH AVENUE 1825-A NORTH THIRD STREET ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 241-1501 (904) 246-6699 -------------------------------------------------- ----- --------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 70 . 00 Plan Check Fee 35 . 00 Issue Date . . . . Valuation . . . . 7500 Fee summary Charged Paid Credited Due ----------------- ---------- -- -------- -- -------- ---------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total 35 . 00 35 . 00 . 00 . 00 Grand Total 105 . 00 105 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. t BUILDING OFFICIAL CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 32233-5445 TELEPHONE: (904)247-5800 FAX: (904)247-5805 r� SUNCOM: 852-5800 http://ci.atlantic-beach.fl.us s�13�a PLAN VIEW COMMENTS Permit Application #_0 - a 'f Applicant: C R Address: Project: k3j rnAae �S Q/Your application is approved o Your permit application has been reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed byLid (7-1 O I Signed Date Contractor Notified Date City of Atlantic Beach 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 • FAX (904)247-5805 - http://www/ci.atlantic-beach.fl.us BUILDING PERMIT APPLICATION (FOR NEW CONSTRUCTION, REMODEL,ADDITIONS AND ALTERATIONS, MOVING OR DEMOLITION) Vn DATE LA JOB ADDRES 1, OWNERS NAMFJ4i 4- ADDRESS PHONE: `l./A A" + LEGAL DESCRIPTIO,N�:: BLOCKNUMBER �� LOT NUMBER �� � �" ZONING DISTRICT !� � CONTRACTOR t'+ 1 !�.lC.!,STATE LICENSE NUMBER ADDRESS er' + ,�: ": PHONE CITY , + STATEZIPS�e FAX , DESCRIBE PROPOSED USE AND WORK TO BE DONE �,• �, �» PRESENT USE OF LAND OR BUILDING(S) VALUATION OF PROPOSED CONSTRUCTION & LV f Is this an addition? If yes,what are the dimensions of the added space: '"" feet by '"'"' feet Will the added area be heated and cooled? &/A New electrical or increase in service? t_ New plumbing fixtures? New fireplace? ? New heating/air conditioning? � Is approval or Homeowner's Association or other private entity required? Ko If yes,please submit with this application. WILL THIS PROJECT INVOLVE CHANGES IN ELEVATION, SITE GRADE OR ANY USE OF FILL MATE AL? O. Applicant certifies that no change in site grade or fill material will be used on this project. YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. ❑NO. Applicant certifies that no trees will be removed for this project. ❑YES. Removal of Protected Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. PROCEDURE: (In order to expedite issuance of permits, please follow all steps and provide all information as appropriate.) STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information,please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation,please have Property Appraiser's Real Estate Number available. 11/27/02 STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Please submit Energy Code Forms,Notice of Commencement,Owner/Contractor Affidavit if owner is contractor,and four(4)complete sets of construction plans to the Building Department, which is located at the Atlantic Beach City Hall, 800 Seminole Road, Atlantic Beach,FL 32233 Telephone:(904)247-5826 In addition to construction and engineering detail, plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures,temporary and permanent,including setbacks,building height,number of stories and square footage. Identify any existing structures and uses. 3. Existing and/or proposed driveways. 4. If required by the Department of Public Works,a pre-construction topographical survey. 5. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 6. Impervious Surface area calculations. (Swimming pools may be excluded from total Impervious Surface.) 7. Other information as may be appropriate for individual applications. I HEREBY CERTIFY THAT A NFO N PROVIDED WITH T I APPLICATION IS CORRECT. r � SIGNATURE OF OWNER DATE . I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH, WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL,STATE OR LOCAL RULES, REGULATIONS,ORDINANCES,OR LAWS IN ANY MANNER,INCLUDING THE GOVERNING OF CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION OF THE PROPERTY. I UNDERSTAND THAT THE ISSUANCE OF THIS PERMIT IS CONTINGENT UPON THE ABOVE INFORMATION BEING TRUE AND CORRECT AND THAT THE PLANS AND SUPPORTING DATA HAVE BEEN OR SHALL BE PROVIDED AS REQUIRED. SIGNATURE OF CONTRACTOR r �• /^✓ _ —� DATE 7 ADDRESS AND CONTACT INFORMATION OF PERSON TO RECEIVE ALL CORRESPONDENCE REGARDING THIS APPLICATION (PLEASE PRINT) NAME MAILING ADDRESS PHONE FAX E-MAIL SWORN AND SUBSCRIBED BEFORE ME THIS DAY OF STATE OF FLORIDA,COUNTY OF DUVAL NOTARY'S SIGNATURE (fl AS TO OWNER: .Personally known Cary A.Brown Produced identification r MYCOMMISSION w CC99491741k EXPIRES�/ Type of identification produced January 21,2005 (/Q Jy BOWW7HRUTROYFAIN INSURANCE,INC J AS TO CONTRACTOR: Personally known Produced identification Type of identification produced ) ,,1'�:etyCarty A Brown 11/27/02 *i *_MY COMMISSION#I CC994917 EXPIRES 4 January21,2005 Z ' OONOW TAU TROY FAIN INWRANC4 IW_ NEW IMPERVIOUS SURFACE REGULATIONS On January 01, 2002, the City of Atlantic Beach enacted new regulations limiting the amount of Impervious Surface that can be developed on property. Within all residential Zoning Districts, the maximum amount of Impervious Surface area allowed is fifty percent (50%). Within all commercial and industrial Zoning Districts, the maximum amount of Impervious Surface area allowed is seventy percent (70%). The Zoning regulations define Impervious Surface as follows: Impervious Surface shall mean those surfaces that prevent the entry of water into the soil. Common Impervious Surfaces include, but are not limited to, rooftops, sidewalks, patio areas, driveways, parking Lots, and other surfaces made of concrete, asphalt, brick, plastic, or any surfacing material with a base or lining of an impervious material. Wood decking elevated two or more inches above grade shall not be considered impervious provided that the ground surface beneath the decking is not impervious. Pervious areas beneath roof or balcony overhangs that are subject to inundation by stormwater and which allow the percolation of that stormwater shall not be considered impervious areas. Swimming pools shall not be considered as Impervious Surfaces because of their ability to retain additional rain water, however, decking around a pool may be considered .impervious depending upon materials used. Information verifying Impervious Surface must be provided prior to issuance of Building Permits whenever new construction, including building renovations or additions, new driveways, decks or porches involves any increase in Impervious Surface area Duval CountyProperty Appraiser-Parcel Summary Page 1 of 2 Parcel Summary-Current Ownership and Sale Information - U dated Weekl RE No.: 170295 0000 Owner's N JHIONIDES , CHRIS Property 1291 BEACH AV Address: Unit No. ATLANTIC BEACH 32233 —� Mailing Address: P O BOX 330108 ATLANTIC BEACH, FL32233-0108 Property Use: 0100 SINGLE FAMILY Legal description: 6-1 ATLANTIC BEACH LOTS 11,12 BLK 51 Nei hborhood: 11940904 NORTH ATLANTIC BCH g (OCN) Sec-Twn-Range: �6-2S-29E OR BK& Pager 09248-2117 Map Panel: 558 1 Sale Date: 3/29/1999 No. Buildings: J12 — � Sale Price_ $700,000.00 Heated Area: 3143 Exterior Wall: WOOD SHINGLE Parcel Summary- Values & Taxes from the 2002 Certified Tax Roll Land Value: $501,500.00 Class Value: Improvements: $193,300.00 Taxing USD3 Authority: Market V 1$694,800.00 ounty Tax.• IF$4,776.26 Assessed Value: $694,800.00 School Tax: $5,807.83 Exem p t Value: $0.00 District $2, Tax: 203.98 —� Taxable Value: $694,800.00 Other Tax: $347.75 Sr. Exem t: $0.00 rVoted Tax: $403.12 Sr. Taxable: = $0.00 Total Tax• $13,538.94 This page displays values from the 2002 Certified Tax Roll with weekly updates of ownership & sales. Map-it maps & data are not updated as frequently as the Tax Roll data and may not reflect matching information. Please direct inquiries regarding the maps & data to Map-It Feedback (below). '==�? Map--It Feedback http://pawww.coj.net/pub/property/RENO.asp?RENUM=170295+0000 7/11/2003 Book 112179 Page 131 (Ll 1977 LAWS ��� RAMCO FORM 409 FS 713.13 N oUc& of C oin#nefV�- �� (Prepare in Duplicate). 7ro whom if mai concern; , The undersigned hereby informs all concerned that improvements will be made to certain real property, and in accordance with section 713.13 of the Florida Statutes,the following information is stated in this NOTICE OF COMNMNCENMNT. Description of property :�.�. :' .r, ,'�. �. . � �'.�-�:`.�• .�t-r!• . . . . . . . . . . . . . . . . . . . �.� . . . . . • . . . • . . . . . . . . . . . . . . . . . Gen 1, ri 1 n of inij Drytialents Ah" .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • . . . • . . . . . . . . . . . . . . . . . . . . . . . . . • . . . . . . . . . . . . . . . . . Owner . Address .: ..r i ' G? Owner's interest in site of the improvement `-'.. ., Fee Simple Title holder(if other than owner) Name . . . . . . . . . . . . . . . . . . . . . . . . • . . . . . . . . . . . • • . . . . . . . . . . . . . . . . . . . . . . . • . . . . . . . . . . . . . Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . ... . . . . . . . . . . . . . . . . Contractor V. tG',. Address . . � . a. . � . . +. T f�..► � � .�. Surety(if uny) . . . . . . . . • . . . . . . . • . . . . . . . . . . . . . . . . . . . • • . . .. . . . . • . . . . . . . . . . . . Address . • . . . . . . . • . . . . . . . . . . • . . . • . . . . . . . . . . . . . . . . • . . . . . . Amount of Bond S.. . . . . . . . . . . . . . . . Any person making a loan for the construction improvements: Name . . . . . . . . • . . . . . . . . . . . . . . . . • • . . . . . . . . . • . . • . . . . • . • • . . . . . . . . . . . , . . . . . . . . • . . . . • . • . . . . . • . Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . • . . . . . . . . . . . . . . . . . . . . . . . . . • . • :. . . . . . . . . . . • . . . . . . . • . . WINDOW REPLACEMENT and STORM PANEL PLAN, DETAILS and SCHEDULE For 1299 BEACH AVENUE ATLANTIC BEACH, FLORIDA 32233 PREPARED BY: PETRA MANAGEMENT 904-241-1792 APPROVED CITY OF ATLANTIC BEACH BUILDING OFFICE JUL 17 2003 DRAWING RLE NO.0-7,0 MAP SHOWING BOUNDARY SURVEY OF : /� /ng/e Rainf Oppoai/e P•47 LOTS I I AND 12,BLOCK 51,OF ATLANTIC BEACH,ACCORDING TO REPLAT OF MAYPORT TERMINAL COMPANY'S MAP OF BLOCKS 41,51.12.61 AND 62 PLAT BOOK 6,PAGE I,OF THE CURRENT PUBLIC RECORDS OF DWAL COUNTY,FLORIDA. TOGETHER WITH THE LANDS LYING EASTERLY THEREOF BETWEEN THE NORTH LIE OF SAID LOT 12 AND THE SOUTH LIE OF SAID LOT N IN SAID BLOCK 51 AS EXTENDED EASTERLY TO THE EROSION CONTROL LIE. Erosion Control ilm .Ing/e fbint NS 48 ti V I I V I � � o JtnN h � ;u aC a G V H � W -- -- -- -- "I � a� 'S Z TH/RTEENTH rljm) STREET 40'RAS//T-OF-WAY R j5 N-93"2/'/9"E- 230.7.8ir" I m ,� .'.- 2140 a9'/rvn Rpe fa dA wen A cox eSorA'Wad ••' '� -�.ti '• - i :- b'?t.4' I'Weed Fenee ...�:-•... .. .•1.! ` � }, j] o�o /-BTORY FRAMIF 1• NZ LOT / �. . I. 3: — .: � <----- — �.k :1. Ali V c '� .nw. e ! LOT / a : '. .'_. l` �• .O 1 N QQ a :'-.'. ,F :..'t i 829 8 [N :: .: :'L'araere/e"WfiR -:'••::.'.:' 4 e `:0.f' 9bM, - •o• / I Orem Lix - -•I: �l $ .• 0.4'6M/ LoAe'/YJk OriYe -� :. 41�4ad�en[e L-----� �:-•` •• .'' ���....'- I Q �\ tM , Zoo-Do' S.B3'2/'22W. 232.2&' R � I O op`1 O�ignia/Eas!Lo!Gine By 1 LOT /O, BLOCK 6/ p/A'Bsek 4 page/ • m -- x 4 0 AVE -ric AAS A},, sI2E-: csrr� � �xd G OX I `�J I I ECIO N D rLDI-3 F-1, FL.PSI . NOV W 1 N D O w s i Simout7on Windows are wsW to ANSA/ DA 1010.2.971ASCE 7A8 ased by the Florida BWldig Code implemented Mare 01,2002. Simonton Windows ar tasted an independent certified testing f4cility and a n thud party approved by AAMA.The Florida ' 8 � AAMA as an appioved evaluation entity. No Simonton Windows and doors are teted for stracuwd nmW as prascribcd x ader the c ode and are evahmW for air iidlltmdon,watat rosisu=,operating force,forced amY test am pressure,and overall dcsiga pmsmm The chart below was taken from the Fl hook and shows"p pressures as they equate to wind speeds. DESIGN WIND LOAD CHART 1 ane 2 story$WuduM EXPOSURE e WALL ZONE TYPE/ 100MPH 110MPH 120MPH I=mH 14OMPH IMVH 160MPH 4 wdw/1W OP20 DP25 OP30 DP36 DP40 OP46 DP50 4 doom f IDP20 DPW DPU DPW DP36 . OM OP50 4 dowi7oof OP20 DP25 0P30 DP30 DP35 DP40 OP45 5 wdw/20sf DP25 OP30 DP35 DP40 OP46 DP66 DP60 5 door/4CW OP26 DP30 DP36 DP40 . OP45 DP50 DP55 5 j do"110ef DP20 DP25 DPW OP35 DP40 DM 0P50 MCPOSURE B 3 story ObIgAt" WALE ZONE TYpE/ 100MPH 110MPH 12OMPH 130MPH j4aWli 153MIH 16OMPH 4 wdw/ZOs1` DPW DP25 DP30 DP35 OP40 OP45 DP50 4 I door/40af DPW DP25 0P30 DPW OP40 OP45 OP50 4 , door17W DM 0P25 DP30 DP30 OP35 DP40 DP45 I 5 wdwr" DP25 0P30 DP35 DP40 OP45 DP55 DPW 5 door/40M DP25 OP30 DP35 DP40 DP45 DP50 DP66 5 dom70sf DP20 DP25 DP30 DP35 DP40 DPW DP55 7(7orporate Hendomiam Rioamar Office Park.5300 fldme Road.P.O.Om 1646.Parka bu%WV 202-1646 'Ilii:304.416.71261•800,5419118•Fan:304.485.1476.wwwcsimanton, ro JN :AMERICAN WHOLESALE FAX NO. :904 519 1301 Jun. 17 2003 11:41AM P2 low v. AAM.A/NWWDA 101/I.S.2-97 " TEST RE,ET'OR'T' SUMMARY Rendered to: SIMONTON WINDOWS SERIES/MODEL: 07-70 TYPE: PVC DoubletlungWindaw with A9 Reinforcement Title of Test Results Ratan. H-R65* 37 x 76 Overall Design Presses a dS psf Operating Force 281b max, Air Infiltration 0,08 efin/£t Water Resistance 9,75 psf Si uctuiral Test Pressure ±97.5 psf _De lazing Passed Forced Entry Resistance Passed Reference sh.o�ld be made to Report No. 05-30357.02 dated 03/27/02 for complete test specimen description an data. For AR.CHITTU.R.AL TESTING, INC. Digitally signed by L nn George Lynn Georgc, Project Manager LG:nlb I � l :AMERICAN WHOLESALE FAX NO. :904 519 1301 Jun. 17 2003 11:41AM P3 i Alk mw Architectural Testing AAMA/NWWDA 101/I.S,2-97 TEST REPORT Rendered to: SIMONTON WINDOWS One Cochrane Avenue ,. Pennsboro, West Virginia 26415 epart No 05-30357,02 est Date 03/06/02 Report.Date 03/27/02 Expir tion bate 03/06/06 Project Sum ary: Architectural Testing, Inc, (ATI) was contracted by Simonto Windows to witness perforynance tests on a Series/Model 07-70, poly vinyl. clzlo.i.de PVC double hung window at the' facility located in Pennsboro, West Virginia. The sample tested su cessfully met the performance requirements for an H-R65* 37 x 76 rating. Test specimen description and results are reported herein. low General Note: An asterisk (*) next to the performance grade indicates that the Yize tested for optional performance was smaller than the minimum test size for the j 7roduct t e and class. �41001.OJ for gateway performance test results, Reference ATI report #01 Test Specification: The test specimen was evaluated in accordance xith AA4AA1NWTYDA I O ULS.2-37, Foluntary Specifications for Aluminum, Vinyl(PVC) and Wood Wind ws and Class Doors. Test Specime Description: Serles/M del: 0770 (Reinforcement code A9) Im Type: P C Double Hung Window Overall S ze: TI-3/1611 wide by 6'4-3/8" high Top Sash Size: 2'.9-1/16 wide by TO-3/8" high 1111 Bottom Sash Size: 2' 10" wide by 3' 1.-3/8" high Screen Site, 2' 9" wide by 3' 1-51811 high Finish: A.11 vinyl was white. 130 Derry Court York, PA 17402-9405 phone; 717.764.7700 fax: 717,764,4129 www,archtest.com :AMERICAN WHOLESALE FAX NO. :904 519 1301 Jun. 17 2003 11:41AN P4 o. 05-30357.02 Page 2 of 6 Test Specimen Description: (Con.tin.ucd) „ Glazing Details: The sash were exterior glazed with 3/4" thick, sealed i.t sulating glass fabricated from two sheets of 1/8" thick, annealed glass and a st el spacer system. The insulating glass was set onto a double-sided adhesive tape and sectu ed with ual durometer snap-in vi'iyl glazing beads, Weather., ripping: Descri tion Quantity Location „ 0.187” acked by 0.210" 1 Row Sill high pi a with center fin 0.1.87"backed by 0.250" 1 Row Top rail, rote for and exterior high pie with center fin meeting rails bottom s•files (sides) NO 0:187" backed by 0.250" 2 Rows Top sash stik s high pile with center fin 0.18T 'backed by 0.340" 1 :Row Exterior m.ee ing:rail, t ottom sash high pile with center fin stiles (exteri face) 7/16" diameter, offset vinyl 1 Row Bottom rail jacket/hollow foarn-filled bulb 0.187"lbacked by 0,500" high 1 ,Row Bottom rail vinyl j cket/foam-filled C -fol leaf 0.187"!backed by 0.250" high 1 Row Head hisert vinyl j cket/foam filled bulb 0.187 backed by 0.300" high 1 Row Top rail vinyl jacket/foam filled bulb Frame C nstruction: The PVC frame was constructed using rniteied and welded corner construct'on. A rigid PVC snap-in adapter wap located at the head. Sash Co struetion: The PVC sash were assembled utilizing mit red and welded corne.r construction. ScreenConstruction: The screens were constructed with extruded aluminum. Tb.e corners were squ a cut and secured using plastic corner keys. The fiberglass mesh screen cloth was held-in-p ace with a flexible vinyl spline. j Poll -11 :AMERICAN WHOLESALE FAX NO. :904 519 1301 Jun. 17 2003 11:41AM P5 MOP ,OS-303S7.U2 Page 3 of 6 ..Fest Speeime Description: (Continued) Hardware: Descrir tion Ouantit Location Metal cam. lock and keeper 2 Lock rail, 8" i i from ea h end with mating keepe s at the a teri.or rail Plastic It latch 4 Top corner of each sas Metal ivot bar 4 Bottom come of each ash Consta�t force balance 4 Two per jam , 3 coils er assembly system. mth locking tilt shoes I PVC ssh stops 4 One per end c f each.jai ab Molle plastic "U" channel 2 One at mid- wi of eachinterior jaar.b rdinforcernent jamb track, at the botto rn sash tilt latches Drainage D es QuantiLy Location 1-1/16' wide by 3/16" high 2 Exterior.face bfrill, weepsl t (with.flap) 3-1/4" in from each en 1" wid by 3/1.6" high 2 Sill intermediate leg, o e at each end weepsl t 3/16" iameter weep hole 4 Bottom raila id keeper rail glazing pocket, 7/8" ' from ea h end 5/16" ide by 1-3/32" long 2 Slotted cavit3 plugs at ill/interior weepsl t jamb track in ersection W" Rein fore meat: (Simonton code A9) The exterior meeting rail contained a ustom shaped. extruded luminttm reinforcement measuring 0.750" x 0.492" x 0.062" (ref ence drawing #56110). The interior meeting rail contained a custom. shaped, holl w, extra ed aluminum reinforcer-ient measuring 0,796" x 0.989" x 0.062" (reference dra 'ng #60 11). The top sash rail contained a custom shaped, extruded aluminum reinforcement me sexing 0.748" x 0.394"t5,611 O,U62" (reference drawing #:16107). The top sash stiles contained a rectangularshaped, .ruded aluminum reinforcement measuring 0.748" x 0.472" x 0.052" (reference drawing1.). The bottom sash stiles anal bottom rail contain d a rectaigular shaped, extrudedummum reinforcement measuring 0.748" x 0.866" x 0.062" (.ref ence drawing x`56109). ri :AMERICAN WHOLESALE FAX NO. :904 519 1301 Jun. 17 2003 11:42AM P6 05-30357.02 Page 4 of 6 Test Specimell Description. (Continued) Installation: The 'unit was installed in a wood buck constructel of non iaal 2 by l.0 Spruce-Pipe—.Fir##2 construction limber and secured to the buck using sevente�n#8 x 2-1/2" long screws, seven at each jamb and three at the head, evenly space (embedded 1-1/2" into the buck).] The interior and exterior perimeter was sealed with a sit cone caulking with the exception of an approximate 6" long void at each interior sit) corner. IM Test Results: The result' are tabulated as follows: paragrgph 'T'itle of Test- Test Method Results Allowed 2.2.1:6.1 Operating Force Top Sash " Opening 22 lbs 30 bs max. Closing 20 lbs 30 bs max. Bottom Sash Opening 28 lbs 30 bs max. Closing 24 lbs 30 bs max. 2.1.2 Air Infiltration per ASTM L 283 @ 1.56 psf(25 mph) 0.08 arn/fit2 0.3 c /ft2 max. i Nate #7: The tested specimen meets the performance levels speci zed in A .A A17VWWDA 101/I.S. 2 97 for air infiltration. 2.1.3 Water Resistance per ASTM E 547 (with and without screen) WTP -2.86 psf No leakage No leakage 2.1.4.2 Uniform Load Sta-uctural per. ASTM E 330 (Permanent set measurements reported were taken on the exterior meeting rail.) (Loads were held for 10 seconds) @ 22.5 psf(positive) 0.023" 0.1 2" max, @ 22.5 psf(negative) 0.020" 0.1 2" max. General ote: Mo end measurements were taken on the m niber m asured. The measureTnts stated above include displacenient as well as bending This st tement applies to all Uniform.Load tests performed. a lw I :AMERICAN WHOLESALE FAX NO. :904 519 1301 Jun. 17 2003 11:42AM P7 i aye. 05-30357.02 Page 5 of 6 w Test Results: Continued) EgagrMh Title of Test -Test Method Results Allowed 2.2.1.6.2 Deglazing Test per ASTM E 987 Top Sash In operating direction at 70 lbs Top rail 0.060"/12% 0,500"/1.00% Meeting rail 0.060"/12% 0.5U "/100% Mw In remaining direction at 50 lbs Left stile 0.030"/6% 0-50)"1100% "/1.00% Right stile 0.030"/6% 0.50 "/1.00% Bottom 3ash In operating direction at 70 lbs Lift rail 0.060"/12% 0.503"/100% Meeting rail 0.090"/18% 0.50 "/100% In remaining direction at 50 lbs Left stile 0.060"/12% 0.50 "/100% Right stile 0.030"/6% 0.50Q"/100% I I 1 2.1.7 Welded.Corner Test Meets as stated 'Meet$ as stated 2.1.8 Forced Entry Resistance per AAMA 1302.5-76 Tests,A through G No entry N entry i ..JM :AMERICAN WHOLESALE FAX NO. :904 519 1301 Jun. 17 2003 11:42AM P8 0S-30357.02 Page 6 of 6 'fest Results: '.Continued) Para>*raph Title of Test- Test Method Results Allowed Uptional erformance 4.3 I� Water.Resistance per ASTM E 547 (with and without screen) ' WT:P =9.75 psf No leakage No eakage 4.4.1 Uniform Load Deflection per. ASTM E 330 (Deflection measurements were taken on the exterior meeting ail) (Loads were hold for 52 seconds) @ 65.0 psf(positive) 0.58011* L/17j 0.189" @ 65.0 psf(negative) 0.551"* L./17 W 0,1.89" *Exceeds rhe maximum allowed for L/17.5 but complies with all other requirements for this testing. 4.4.2 I Uniform Load Structural (Permanent set measurements were taken on the exterior meet�,n.g rail) I (Loads were held for 10 seconds) @ 97.5 psf(positive) 0.060" 0.1 2" max. @ 97,5 psf(negative) 0,070" 0.1 2" max. Detailed drawings, .representative samples of the test specimen, and a co y of this report will be retained by A I for a period of four years. Tho above results wert secured by using the designated test methods and they indicate compliance with the perform ice requii ewients of the above referenced specification. This report does not constitute certi :cation of this product, which may on be granted by the certification program administrator. For ARC IiCT `TURAL TESTING, INC: Digitally Aigncd by L nn Georgc Lynn George Steven.M. Urich,R.E.. Project Manag .r. /Sle, for Project En 'neer LG:nlh 7/ /V Z_ 05-30357.02 mm ,1 :AMERICAN WHOLESALE FAX NO. :904 519 1301 Jun. 17 2003 11:42AM P9 gg % )fill I I i I I Nil za I 1 I g _�- - - - x - 1 M 1 rz $ I I dyIVi ^,... El j j I I } I 1 I I u 1 I hilt - ` --+-I R L G'0 e�c'o •-•--j '. � CL .. -.. lei �n mCL z n a a I o T ](A) { S TO R M B R E AK ER PLUS AND WV"- 4 MAF PQCCUCTM tS iR FARWAT-IM PANnOW-1i HXE FLORIDA CUSTOMERS a DOUBLE HUNG (EXLUDES rlA3cA3 Cr PROFINISH AND LUMINESS) RETROFIT ONLY INSTALLATION PROCEDURE M m nbu%or Track (11 Inwor F, s (� Lmdo(C) m M ' �+ `xledor Track � Exterior Tro � I In G O )> Z X a (N 4M*(A) Q LL- ROTES: A. USE A US�0�10 X 2-1/7- FASTENER W EICTERIOR 7RAG1( OF THE WEAO TO ANCHOR HEAD — s 0 T1jE s, A a e&aw2 >�E W AOE»io rriba g -- t11 Y CONsrP,(ICTto�l t iv BE »iiEll[1[} Ti,-- .iA�sf 8: REPLACE FAVENER N lf-CHAXNEL WnH A iP8 X 2-1 2- FaMEP. WHICH WILL AN--iOR V--CHANNEL TWOUGH THE 'AM" TL THE SU CTIJRE (STCRMOREPYXR WJS ONLY) rte,E STAMM y r w Q ANCHOR THROUGH THE JAMB 70 THE OPE14NG WITH A f10 X 2' FASTENER (3" X 3/16" TArcom J TYPE IN MASONRY CONSTRUCTION). LA^..AFE IH INTEiOOR BALANCE TRACY,. A+.dx,.,-t 1.a.pvpwtyof SW-b. srs..+.wd.r*W*01 F*PUWY-d L¢fl 0 ANTASTHROUGH lNE AAMB TO THE OPEMNG WITH A 0 X 2-1/ FAS VE , (3-i/2' X 3/16" .per to lb alar wAl. n�a.mo.,t r w..�.+t Om...4r.s m u,..W+—d LU .E- tl0t HERD bdMWERr i ARE sto, 1HSTALis MUST A0.1UST ANcHoR LENGTH TO MAINTAIN Rt atO11, wu- is d M-deal+cr ygpo d b g-ft far,is.a h, w.nor DPW t, pWNWUM ENBEDMEHT IN SUBMUCTUREft ° s 'r ` e� = 6%ratrAA not s„a m.rs"Mrt..ty,h k.nfa► 3 i,r.r.�►,r,metdn.e r.udr do.an.nt.MoS r p,.p.ir abtAl,.t inn we6.r..wv. T°;cc R,�� R by nates $°; o� $�..a br Date � I NO001 .0 S IMONTO ON' v�am rare x I e n o x s Drava br_ . ?D FIT pI Sft-k= ALL RETROM DH T aws.• ct MMA ANn '.R"Ll6REAKER MSTA" 'ION PROCEBURE S TO R M B R E A K ER PLUS AND aI®rc�>•�r a�ouV axw is n s'uraio►i<saes wvrarz�,w aroaa FLORIDA CUSTOMERS o RETROFIT DOUBLE HUNG a ! (A) (A) x6xinr Tropic F- (WTH DEL UXE NAIL FIN) cc v INSTAL.LA,T ION PROCEDURE , Ezteruor T In m (U � - I C ` � ----Eitte-ioe Track a•'� Interior i (C) I (+J (a)I 01) V-DUMIEL(B, --i Extcia- Tr erior TraeSc m r In Q Exterior T e-eor Track Z I X (A) a (+) Cl LL NOTES P. USF A 0 X 2-1L1-2Z FAFT NER R_wIN EXTERIOR 7RACK V THE BEAD TO ANCHDR HEAD - E ABOVE THE SEL. ATV 6" 1{t`AD I 71;E I " BALANCE TRACT' AN( i INC UPPER PND LDWER JAM TO SUDS7RUC (li 3-1 X 3/15 TAPCON TYPE Ait'W)R IN WASONRY CCA(STiUCTION 1N E0MI THE MEAD ` THE ) E- REPLACE FAS7ENEP.1N U-dLVD61 VA7M AA X 2-1 2 �r�� �� " FASTtrIER VMICH PALL — -i ANCHOR U-CHANNEL THROUGH THE JAMB THE UCTIRiE (STORMBWAKER PLUS OWLY) Cl O: ANCHOIRN THROUGH CO'N578U 70 THE OPENING (LATH A O X FAt7ENEit (� X 3/16" TAPCON � s LL IN IN �be a..e}.t IndY+r. !�d.ar..t r b. ---D; A13pHOR THROUGH'THE.LAMB TO 'TETE OPENING V97H A #10 X 2-i/2" FASMER (3-1/2' X 3/16" eO eds*d a Vit'i I.b`�ii �'°'F ��"�`� JO TAPCON-TYPE IN MASONRY al!GIRUCTION� LOCATE D; EXTERIOR BALANCE TRACK. �1 +►i;ab.6-W"Kvwfo`b-W�d rod. � w �"""F'� = Wi.,Mp- oemwvL W.n.'A- ha nd roat!h.r.ow.rwft b qw- 3 i+f.nrtoU.n a*.bw m 9w a.p.0-ty abbm fan .*W..rs._ Q S Tiev34 0 :as ll& a br: Date Rev Revisions Revised b�: -Mete 1�. INOOD3 SIMAON TON* Vendw Pam Numb=s: 1N I N 73 0 w Q ` Drnera by, pp Z: FIT to 09 fO 02 ry _----- ,fiw.is- OrMfWIT nIa WMrl afVr MAll Mid r�eaclertffs COI OWW AACI1 M(SM SOAM" 1. Slav IStal MMM IIo MCOUCr ONtMNM maaoW lkaa)Mr MW DCW"N —�;[..� Aamwrra wm M adw OWN M naa SMDM M& Is Its,(7wNLL N1OM) rra'I01 aarlW mw NMo IMOs NM/E AUDI v At OW MMV IaN Or M AMMY AMM""Omc tw A r:amw•RP7tE711E NIDRQ ao°N' MIC we sam As AEON R M A1A1eoIe11OM NOW S1aEr Ilea Nu L raM[R(NSI NJl A C (6SEL7aT SSD1M) MlCIIPAwNI/ICM S F6M N AGM RSNt NNM A!E a w TN1raNR EIOI.l [ 1.17!'� 1 1 ' 1. ASL Aa�l I IMMMLIV AOS-Of Rw EMC!AAO/0"* M AlL/Mf®P wear-MAD N ARO7IYMS NM s6Tar/IELI.1 ar 9r.1Nat[a1rrO®Om[AS NOr AE AtlEr/I/SSOI�a r011lS ALL AINNar MET ER MI=MU MINE SOW-MV ALLR E Ja04-fM Alec d mf L Etta m E S°H-M/Now"am MINY®w swan SRO.1NN1>r w wmw A -I zur E , rRo/wr.,a rm mo sr fs fa t Am.w encs Ka Nmw a AASCRf m aLL mumv JMLL E As tatpi!(Mata°ROHR MOIW FULL PANEL HALF PANEL 9 ' A i � A � P!VI�i wsm �rw.arn+ER R u.R S Merz Le -Ip'..r/r wa-N A.eraos w eco.r t A.,.w'MwrwR•As rvArAclaEn m�SOLIO STORM PANEL 1R rom nWm cc M As am Rxwaa Actr9cNlur. Atill 11-111- -1 It i Amm A A [NEST DMOMW we PUMP aINOEIF or umm mmm s r.VV a T am NMRANa s 1.j/1: A7)7, 04"AMMO SNeI E Berour nom®'[m M Comm C"Km M.0-M s w SHAW cwt E rE1SSos O A.fe pE's arm S E 11/7'lora rNaaNl 51101ta fI11Iim BN6 AB I- WOW !w NNlld on /IN SIIla.4 -falls*ouft.GRIN) a Ila'(7B7A1.NDIIQ / A>)N elft wrc mww Aa'C/Imw mew"!MNu;w Moa E taro w M i .ti0mw•(E nvnw No" s.000" 10351140 a0 OF Nm1 AVMM NNA E lase BMW IS A64M W MW A7Y 4.4"' 1 rmnow Sow 7_�' "I SNNAil1S bJ1B JEC/Ilei[a AAOaINMt SIaLL L o raoMm w MRS AI)•Aa} M7Yao°' 1°0`EAJ AMIIeIMt AE.rnnlMr F! RNK'IErE AxcuNs IStE saeatU----- Y- ro)m wslMa m/aElr smr w[:IM --!/1mw.rl mwm BC AO aiOI mft 1!llCINOR/7N $Td " a 1)WMW BMMar R V~AMMOIS AN Bm MIIR[I IS MB NE -1 z raY 4—.cen--1 z t7a'1- 8 -(2.w23-L T .COMBINA170M OF AO/ACEMT PAIRS OF SOLID PERFORATED STORM PAN£Ls Ca`ant Gent°rn muff 1 CA-. TYPICAL £LEVATfON w 7/S•aur-n AaRR mu M Bawar ammo Nm M ea401I1[amt NSI. �jLL PANEL HALF PANEL A c a r1/4 No°XmW am w[mir'Iain wm mro N Noun sense alsx An 1 PERFORATED STORM PANEL maw ICN"a NM E anlmma JcaE:yrr•.i• W N am fw rmmr SnM w M CW 0000WM MlroS E IOrtB w IW MW Ott ANJIOB SMI.L Its Boni!m AOOr M MN SWFCRRM SBM SUM LL MORS A AMMIC SMM AS MOOM AN AMN7 N•I)t w APOW. —2.125— (o As SNLL E�.. "'S"Lo'O"N"ALL Or M 1lCVN6SNUM AB SRCVMDM r� CMXft"?E ANOMs(SIE S0s3)L J �- .« CaaNnt AA?aR tett a�EOU[)�'�,yy. -7e0• .XB' Br NEAM7A"oNVMCMM I a Mals Mr AE or rawam mozmv Or t omm N6WNNE/mmu stow Or aC7C16 1 Xm a(JIRrr a VMS Sr IV A@r NM Awwm a a t 1 N 1W L mm 7. A NULL L M Aerwilm/IY K M c0s"WIBl m wEr M sataeNa R M sIN1cw MRS SIMMa IS M ArMW m MISE tMN'Bl AVOOMM No Bar14/SMLL Har E AM MOF m OMIBEM SEAM E MAP MI1E AUNIft .. o e o e umno R r a MwVMv R TBS BRNEOI a WENC AAO OOJS aR!SOME J MM°w nM A ' e o e o llrt JPEQ MIRGe t o NRS M SE CORIMMa MWIF MW NE A C A Dow ov so m E 1FROM t Nr o MY IINOM[.es mum'lln NF oar Ir OVAT W! sem w NIa t:c a rEI1Nm IE/9E OOa/Ar M1MM MOM M mama OerEm w Na f! 'i 1 J ° ° I�S�J. . i 114 1+ " y r/ 1 A , y (q)NR R C a Nu K VMVMW Nwo r A101M(IA MEAAMM J1wmt EM)R.wr Jrala fNC rr Ii N N /, MC (4 NM yyC MOSCM JIM E NVWI$R A 11641190MIEO JWMlX E ANQSRCr SIIW Nu . MME NE 7mor LC°1E(CBN)IBI M NIGER AO wo SLL L 119 1 FM rw tN0'a Ibt K M PlA OJNM1 M IEmrR ADN AS A W[MNm DOOM m NE PEA BMM ii i A MU SJENr m as UDEN NE art pwm a owe tar m"m i ! (�NNr.SVM MR N t.NE Bot AN NENWt MAI NO SENIIM Or NE MWONOW DOMIX R n i This Is a Master nrri -ml I t j L " Expires on: �Y CDNDIE,E AMOIOR mw SOW AQ-�� , �,. NNOEr[AA OLIO(S[E KNm aQ ,., COMPONENTS rIa AAr. Ya I� F.B.C. 1 l4a SO!D STORM PANEL ,tw I Nn , TICAL ELEVATION PER(0 ATED STORM PANEL .040" SOLID/PERFORATED BERTHA AS SHOW . KS TYPICA/ r'VATION ALUMINUM STORM PANEL w..E 1/1'JrN.CAPy A..wM4. 3/4/02 I L E C O I N c. EASTERN METAL SUPPLY, INC GAM AMnHnun VEXIM s arosma COMPANY IM o 02-056 SECTION A-A m MaratrNx.tN�wiw v?JIw `� M E a -t- - alIL1ENryak.P.[ r - - t - - arrtEr I or ra ]WOMftLYNW l7e HIa7 - - - 0 A123' ICJ30' -far .lJS' R17o' 't i ii RlJ7' �. Rrlr + •� lb• RAat' ^ Q xQ JN• . Alas kur jw fiRl R .IQO 273• � 1�� �� zsrr zsrr 23N• 10g1'Mt 1i-nr j_ ao- 1 © h' HEARER © d'Max. 'll' BUILD OUT O .0' HE11 7P Q 3'ANGLE BUILD OUT BRACKET � � ® I low,ir-r rr sr ,W.r .orc,.vr•-r . jgdCK _ .ort r.M-r• aerr..yr-r• �SROF .rrae Acroswrr T �f� 3 fi O ..q• 1 /!Q 1.OVRtf�� .ORI' v � � L _ = � �._. _ ..� >a 4 � ZX . �Aets• ius !•upr Roes" WARM "F-ANGLE TRACK ® f' TRACK ANGLE 9Q 25r2"STUDDED ANGIC '• '°R`1'I ''' 1 D KEY HOLE AT PANEL_ 11 XEY fIOLE WASHER 1�Z Af(N/ WALL jJS srm+,r.r.n...Hoer ANGLE N7fN SfUO . ge crt,Y,•-r• K + SORA FW-1• ,+er (dope LOW xratsAr jJY�'` Q aw .lrr .IraD A rtc '� s �'w� �• (JJ !r'� � � �� 8 z Rs r+uRli�ac�ou=caws � � �—"f L M w+ . l stso' 13 1'xSYMAX.)xf/d' (� �. SCK �C�� r•�rr 1• Q7 / .('x1`rr�._FLASHINQANGLL" ANGLE KM SPUD, \J aw,ta•-r I! soRA AA`.r• . f6 .'j, 665,7-x1d'LONG WALL PLATE �arlr-1• -i This Is a Me:tar rnrr�n - }- Expires an: r a .040 SOLID/PERFORATED BERT As SWO .Ins• ALUMINUM STORM PANEL scut -! COMPONENTS EASTERN METAL SUPPLY, INC aR VW AVOM FtAFW ASC MR Otl M.. •J17 IIm m o R www m MFA t IL 30 �fTA - sruo w nc cAs7 Smc nwr Ilsnee�tlRorKparre carn+erl IrHrnr spot NaW wo7 0?-0: r..�.r faA°�Ivr-a.n.r p.u�+-I,n tNr.wie �� Es-a�wsu MLL> >u iR i �• k MAXIMUM DESIGN PRESSURE RATING 'W' (a-s.Q WITH CO RESPONDING MAXIMUM PANEL LENGTH 'L' (Ft,) AND e9T STORM PANEL A INST ►A710N: C(ZRESPONDING ANCHOR SPACING 'S'•(Ing) SCHEDULE (1) PANA.S INSTALLED DIRECT MOUNTED AT EACH END MUST BE INSTALLED EQR /NSTAUATIONS IN CONCRETE. CONCRETE BLOCK WITH cOA4PONl w Q Ar EACH END,As SHOWN ON APPUGBLE sEcwNs OF DRAWING IN ORDER FOR INSTALLATION TO BE VALID FOR EVERY APPLICABLE AND WOOD FRAME STRUCTURES rR PANE LENGTH[PANELS WHERE Al LEAST ONE END IS COVERED WITH COMPONENT 0 MAY BE INSTALLED AS LONG AS PANE LENGTHS ARE EOU41. OR GREATER TH4N 66' Lir.PANEL LBOW Nom.AVAL Low= M-AIAIAA B%CM1 "AWARN ANCHOR SPACINGS ARE VALID FOR (2)PA�O&E®RECT'MOUNTED AT ONE END BUT WITH m4cK5©QJ, Uvaldw 000m a0w'At1AANN P NEL W(XW Ate) now'ALUlQN A/INNEL Q OarlrLwArm hmo i AINpq E S Q.. J 1/2'EDGE IXSrANCE FOR E D. LESS THAN J 4, B.® AT THE OTHER ENO, AUY INSTALLED IVfTFlOL/l fLASH/NG nWs"Amnw 1/?,' REDl10E ANCHOR SPACING BY MLIL71PLYING AT 774E DIRECT MOUNTED END,AS LONG AS AWE LENGTH IX E' ML OR w Cs..�1 ArOan acram acme a rm* sea/6ra• uraw » mart 1 cmm SPACl/G SHOWN ON SCHEINAE 8Y THE GRE47ER )TIN 66' F FLASHING®IS INSTALLED AT vmECT MOUNTED END, 11 i Lir .A r0 12 1.1 q i ,oK 6 If 12 IJ '� FOLLOWING FACTORS. (NOTE:Min. THEN ANY PANE LENGTH WILL BE VAUD AND APPLICABLE E. D. FOR[NUC-AV ANCHORS IS 1 1/1). +25.4 -25.0 12'-0' 12'-0• I1'-e' 81-61 4'-0' 12'-0' 12'-0" 1!•-9' 6'-6' 12" FOR THIS OPERAWN TO BE POSIBLE REDUCED (3) PANELS 1NSr 0 WITH TRACKS QT()AND ET AM Bf Mvr WITH SPACING OBTAINED USING FACTOR 51ULL NOT BE © ® THE LESS THIN MNAVUV SPACING INIXG7ED RIR WITHOUT FLASIINT ARST AS LONG AS PANEL LENGTH IS EQUAL +250. -J0.0 I2'-0' I1'-3' 10'-9' 9'-6' -IL'-5" 10'-If" 12'-0' 10'-9' 8'-e' l?• EACH ANCHOR TYPE AT ANCHORS LEGEND. OR GREAT D4N 66' IF FLASHING®IS INSTALLED AT FIST END. +J0-0. -33.0 il'-1' 10'-6' 8=11• 8'-6' 10'-6' 10'-2" I1'-I' 9'-I1' 8'-6" 12" FACTOR THEN ANY PANE LENGTH WILL BE VALID AND APPLIIGI9Ur- ACTUAL E. A TSN/ (4)PANELS INSTALLED WITH TRACKS©. JQ,n:Q.(8l @AND 0 AT EACH END +314 -40.0 r0'-5' V-10' 981-81-4' aa• 9=10' 9'-6' f0'-5" 9'-4' 8"-6' f?• � CALK-IN WILL NOT NEED TO COVER ENDS WIN LASHING�yPONFNT ,AND ALL PANEL LENGTHS WILL BE VALID AND APPLICABLE. +10.0. -45.0 9'-f0• 9.-41 8•-91 81-6" e•-41 a-11• 9•-101 6•_9• 9-6• 12• J. .86 .75 (5) PANELS INSTALLED KITH TRACKS�n. ®AND®AT EACH END, MUST 2 1/2' .71 .50 COVER EACH END WITH FLASHING FOR ALL PANELS LENGTHS TO BE VAUD +43.4 -50.0 9'-4' a'-to" B'-4' 9'-6' 8-t0' a"-6" 9'-4' 6'-4" e'-6' i1• y' .50 _ AND APPUGBLE. AF AT LEAST ONE END IS COVERED, THEN MW04LAU PANEL •LENGTH TO BE INSTALLED SHALL BE 66. +50.0. -55.0 8'-r0' 9'-5' 7'-11' - 8'-5' 8'-1' a'-10' 71-11, - 11' ANCHORS LEGEND +ss.o, -60.0 5'-6' e'-1 T-7' - a'-1' T-9' a'-6' 7'-7' - 12" ANCHOR AT COMBWARON STORM PANELQ)& A 770N. ANCHORS MIN. +640. -65.0 a'-0' 7'-9" 7'-4 - 7=9' 7=3' 6'-0' 7=4' - I?' TYPE SPACING (1) PAIRS OF INSTALLED PW/THLCO + (A INSTALLED�AT DIVE END, ASUNTED A ON EACH END MUST BE BLSEC170N5 +63.4 -70.0 7'-5• 7'-5' 7'-0' - 71-51 7=1' 7'-5" 7'-0' - 12' TAPCON/ OF DRAWING W ORDER FOR ALLA170M TO BE VALID FOR EVERY APPUCAE PANELMATES 3.0, PANE LENGTH PANELS AUY BE INSTALLED W/BOTH ENDS OPEN ONLY TF PANE +70.0. -75.0 6'-r I' 6'-f 1' 6'-9' - 6'-f f' 6'-11• 6'-f I' 6'-9' - r?' LENGTHS ARE EOL14L OR GREATER THAN 56' CALK-fN 2.5� (1)PoARS OF PANELS 1 + A INSTALLED WRH RUCKS 2 QJ, 4 Q 8, 9OAN0 +73.0. -MO 6'-6" 6'-6' 6'-6' - 6"-6' 61-6' 6'-6• 6'-6" - 12' COMPONENT EM L NOT NEED PANELTO COVER WILL BAUD�ND �HIRG +60.0• -85.0 6'-1' 6'-I' 6'-1' - 6'-1' 6'-1' 6'-1" 6'-1' - 12' (J) PAIRS OF PANELS 1 +$2, INNSSTALQLEDo n CKS 6 AND AT ONE ERD' +85.0. -90.0 5'-9' S'-9' S'-9' - 5'-9' S'-9' 3•-9' S'-9" - f2' ,IS FOR PANEL LENGTH UAIRARONSI5 Or FOR NOT NEED TO COVER E WRH FIASN/N8 COAW rr©f�ANDEALL PANEL +90.4 -950 3'-6' S'-6' S'-6' - 5'-6" 5'-6' S'-6' 5'-6' - t2• �E B SHG MTAUAAONS!MD WOOD LENGTHS WILL BEPAIRS or VALID AND APPUCWLE.+@ INSTALLED WITH TRACKSo ® ' (5)END, UUSr BE INSTALLED AODMONALtr w FLASHING COMPONENTD(TATrONE END, +95.0. -1040 5'-1' 5'-1' 5'-2' - 5'-2' 5'-2' 5'-2' 5'-2' - !1" AS SHOWN ON APPLICABLE SECRONS OF DRAWING IN ORDER f- 6YSSSTTTALLARON TO BE VALID FOR EVERY APPLICABLE PANEL LENGTH[ PANELS ANY BE INSTALLED i 100.4 -105. 4'-II' 4'-fl" 4'-11' - 4'-11" 4'-11" 4'-11' 4'-I1' - 12' W/TRCKS5Q,©•®AND @ AT 80174 ENDS& W/OUT FLASHING COMPONENT ONLY IF PANEL LENGTHS ARE EOL14L OR GREATER RUN 56' 105.0, -110. 4'-9' 4'-9' 4'-9' - 4'-9' 4'-9• 4'-9" 4•-9" - 12• This Is-a Master Prawing. I I 110.0. -I 15. 4'-6" 4'-6' 4'-6' - 4"-6' 4'-6' 4'-6' 4'-6' - II• Expires on: I f&0. -124 4'-4• 4'-4' 4'-4' - 4'-4' 4'-4' 4'-4" 4'-4' - 12' 1204 -123. 4'-2' 4'-1' 4'-2' - 4'-2" 4'-7' 4'-2• 4'-2- - 11' - .040" SOLID/PERFORATED BERTHA As snvllrt ALUMINUM STORM PANEL 5ut[ 123.0. -I,`„9. 4'-G" 4'-0' 4'-0' - 4'-O' 4'-0• 4'-0' 4'-0' - 12' _ /777i-LTE C O EASTERN METAL SUPPLY, INC J/1 N t. 4204 WEST Awns AW rwlT ncwnw t oroOaLnNrw COWANY 02-056 Cl/f Mme.>A� A 311.- n Intl Aw t r+isAnl-ulo G ra 6AAIIIxG N. ta-0o6ely WLIER A TXW J! P.E SNEW t6 or Is nrH V.a1 -67 ' /i+S s HEX WISHER WW wow SCREWS• If-a C W -1 314-WL PEIIETmma 11+s s HEX WAER AM 114 S S IMJPf de WAD N/D DM1aDNx+1/D-S0. WD00 SCREWS• Ir a a WOOD SCREWS•13•a C SCREW WV AND N/7/D if�/.►7' W/1 s/i-a POSE mmm W I J/+-AOL PV&MMK Omd. mm HUE• 12•a a .. /IE�)EDt • I WODD 9 I O t• I 1 £ AEOLVIM I WRTOD WEAVER I t I 1 al® REDIAAED I � sEnR�w1AX/ I 1'1D. I 1°I i s m Cbm I . .6. 'DGIA>� I 4 GaNr. I CONT. 14.10-sa4T/+-s s ALS f 7/leo.J/JZ'WwrM NUr W R ei 1 •EVOW SIW O 12-aG R w/1/+•0-2GwJ14-ss+cs e /P s-s0.1/.•DMus o Er i1�( o 0 12'a 2a C. NEW NRn W f 9 Cant Y- S �+7/11'.4eir WIND mw 7. O I7•a C 11+S S HEX W'OIER HERO Y- 1�sown EROMER HEW wow sawn E W a a /101 S S IAS IWL2- READ N/1 314-AEf.PETEWWN. W1 I SCREWS O Ir a G W/ •S/+•ADn.PEiVE/R1T1DlL W1 r JV+'Wf vENErwWnoN. i WALL MOUNTING INSTALLATION WALL MOUNTING INSTALLATION WALL MOUNTING INSTALLATION SC4E:7/+'- 1' SME: I/I'- 1- SOU:1/+•- I' . ALTERNATIVE 1 ALTERNATIVE 2 ALTERNATIVE-3 I NOTE FOR CONBMMM OF SEL7TON5: BALL AIOOUM SECTIONS CAN BE COMaINED INSTALLATION DETAILS ON EXISTING WOOD BUILD/NGS w ANr Mr TO su/r Ayr AYSTAL[ARON. • SEE SHEET 10 OF 15 FOR LOwomoNS REo ANSTALmw This is a Master Draw ELF f1LSMNG©ONLY APP.SLL Ta PANEL Wv oROER TO AMWAAv NON POROUS CONMWN FOR L• Expires on: ergs f.Er.c. r- ArsTAuATmm ARE oncr vAuD FoR DEAGN WPM LCSOLS AND Max 040' SOLID/PERFORWN ATED BERTHA As SA PANEL LENGnl AS PER SCHEDULES SHOWN ON SHEET 10 OF 15 EXCEPT IMT PANELS LENGTHS FOR ELOOR/CEIUNG INSTAUAnoNS ALUMINUM STORM PANEL SCQcc SHALL BE LIUM M 109' 3/41w Z Far WOOD ERANE caysmucnOH: WOW MEMBERSro BE sOUnERH EASTERN METAL SUPPLY, INC uR PINE No.Z W/sPEcIT1c OENSRY OF am OR Eou4L i L E C O T 111:. +„D War At n MW 1DArr TL5r7r0 t urrAnWwa CDAAWIIY AYYIFM spotn s1w7 02-056 j 101010 ws awt win,nrr erns n atfw /fes-f 1»-1{n.a I��-If71 R t �f� Yf R 1 �� YR OIUWw10 Mf _ OwlEff A.FLOMM 7A[/r71 f 9/[[10 II Or 1 ✓, i � � J �� a. €a'-L'"'. v� "'}' .'.'.':i:. .. _. ..'is•.x 1i�?ii"'�sf�'s4ks+:>.g f,....;e',t` .. ... ..'�i.;�::a •..... .....r.. /IQ'Qa•4/49"LOM:BNL55 i /14 S S Mx N4 MR 1610 -- eLOAM W/114.0-20. r• *VW SNS a r:•a c • S S K&W/K'rymz 1 moor w/1 y4"AN.PGAI AAON. //4'r-zo al/4•&&K S OR I/4•P wu,/Dwr PAlumm w/ans•.aen.1/49•s0. w/r 7/49'Le.PL'NEMMW• IY•ae SCREW M V Arm W/7/49•..1/37" . 1 AIT W/1/4'o-Z&3/4'S.S.AL& re 12'a C /II S S 11EX eA2" 7C. evae savews a rz'a c &J4CKNOrayLr MW f gINE1, Awl, 1/4•/-fvXmr 4 sEsr.Ks w/r,1/4.16.PEMiMIIft �i fACN OF&r FOR PA EL(g• g , 1 1 .; } I 1 ar� • 1 } I 3 I . , 1 eL 1 OenL • L � 1 � 1 WOW RVOER 1 , a `• ' lot®mm iffluin Nq NEAOER I 1 �� 111innn f"Ib. j R 1 SfRVNROW i aASS r/4Y-za..1/4• I Tom WA a £SKS W/ 1z'a a I, 1 491 5 K amu/ i 1 IM MIr a e1Nc Tz'a a c e ; I I 5 cent Rd W/1/4'0-23/4 &S.KS Nlon a stew av4 W R owr FOR rmu CN W/V4'0-2 J/4'S.S . O C WhEX W/I/4'I-YOrJ/i"SS.Ks q� par flow PAM(, • WOVA W WIra C. 49rEW xcaA,ACHNUf EACH Fav _. 14&s NEX""WAIT : w/r J/41&.PENEIR/IIOWCNLY FOR PANEL�i mw SCREW a i:•a c YL1NIunOr PLATE 11NSFRR P610 W/1 J/4LI.f70Yl7R1nON WS a 1Y•O. C e IEONIOIN Or PINE Ar-PEMIWAim ' e LIDIMD7H OF PLATE WALL MOI TING ,INSTALLATION WALL MOUNTING INSTALLATION BUILD OUT INSTALLATION ? SCALE:1/4•- 1' SCALE: 1/4'. 1' ALTERNATIVE 4 ALTERNATIVE—5 ALTERNATIVE 6 INSTALLATION DETAILS ON EXISTING WOOD BUILDINGS. NOW TDR COM9'IATEOfI OF SECAONSi • SEE SHEET 10,,,�F t5 FM CDAGIRONS AYSfAW770W OF fLASIWVGONLY APPLIGI6(E R) IN IMOER WALL MOUNINB SECTIONS CAN BE COMBINED TO M4WAN NNNNNNbbbbbbNNNNNN POROUS CONORION FOR PAN 1N ANY LIAr TD sw ANY NwAwwm.. This Is a Master Prawlng. Expires on:QE.oLQCe CR> Erc� F.B.C. I. MrALLARONS ARE ONLY VAUD FOR DESIGN AINO LADS AND Mo.. .040" SOLID PERFOR4TED BERTHA AS SHOW LENGTH AS PER SCHEDULES SHOWN ON SH£EF 10 OF 15 EXCEPT rmi-PANE1•S LENcw FOR FLooR/CEma INSfALLATTONS ALUMINUM STORM PANEL 3cAa SPALL BE LIMITED TO 109' Z TGR mw nuw coNSTRUcT/0N: WORD MEMBERS TO BE SOUTHERN 111LIE0EASTERN METAL SUPPLY, INCVAIr ..� P#w Na x W/Smcm oENSRY OF a55 OR mm- z AM ow AI9111I'IlLiff l4eK eras�rW44�ai� n7.U1an eemec�n a ��'rt•w07 02-056 149•. pak rl-we.a.Oolra1-pn as r eevr ew ea a 0� an aMWWa Mr - IALiER A 7YLR.k..P.E e SFdw 17 or IS y' i14S7M 1h. M67 ^ .ps ia:'�i.... ay*e�d Sr..: , .. -.�y.,iii 11 .'�Mtin. ,,,.�$.F.%'L. �,_ - .-:•.1 _ .., . 7/16•a0l>.AM'LWO GRASS BRSMW W/1/1'6-20 r 1' . ow S S 1L& W/KE)WOLE 161S11ER /11 S S NIX RASHER HEAD wS. w 116tSHER MEAD OR 1/6•0 M94gVINtf RVAZ NTE 00"sowl5 W/r PENErRAnoN o 6'1/T•0. W/1 7/6•Min PERIEMUGN O 12'ne PET WWN W 6•a.e e.e 1R16O+0 1�01aREA W/114-0-20rJ/4•SSM.S IYODD N7W l�Dla�mE'0. SrRUCR6PA6 AOEDMICT t.NCKPRIT EACH jLNKi, or caw M or E]OS1aAG mum ORLr FOR PANEL lH' ��� BEAM TV BE CERM Or GI 6E D eymO mm • , OR ARC11W PRW W ONAM NWIM a6T� „ro SHIM aL VUAWFL I c L ° 1 Lbn KVW HEADER /L I rEEauRlO _ ' SERIPo ROR 1 , al S S i~--2W14 WIN mff IT'a r- 1 70 pA65 J— 1 1 I•WA —�A— 1 � � ro ERTstIHc 1 , , 7/B'• I 1 7/ML,]/JT' 1 0 NTNG MAO JI �r 1 aNM.NUT O I 3 IT'0.a 1T5; 'O.G I IFRPLUE ] LEG 1 C-L I LOG710N ALnDMlE LEC 1 I �]W/1/4'0-2J/4'SOMC4 SM& LWN C-L V. ilia t AICIDRTT EACH P OM.r rm PAmL mmol T11 or PATE 6' ROOD UET7( W" PUMrK 7/16'OIOI•5/6'LONG BRASS RE'OIARED ED AEq/yIM &W"W/114 20 - I' S S M S W/,Z;,ULE.WASHM OR 1/11 LNl£,/PELLV.E PNNEIRArr Irl S S for MWER D W/1 7/8'MM.PE71E7RI)1CW o rT•ox •� 111&&)VI IUWM WAD wowwowMEAsCREMS w/1 1/1•IIn IIOOO SL'REaS W/1 1/2'Min PEAEMFkw O 6'as PLTIEIRAUON O 6'ae WALL MOUNTING INSTALLATION (D. M.) CEILING & FLOOR MOUNTING INSTALLATION CEILING A FLOOR MOUNTING INSTALLATION ALTERNATIVE 7 SALE r 114'- /1•' '• ALTERNATIVE-9 SC"E r '/{•` '' ALTERNATIVE 9 SO1"' 1/4*- I INSTALLATION DETAILS ON EXISTING WOOD BUILDINGS NOTE EOR COMBINATION OF SECnays: a OF SHEET 0 omr15 APPIM.Im£TO ICONOMONSRED ms wul MouxnNc st cTIDNs rw BE LroMB/NED '°"' """ PL>r:0�L'DN01`°"'�R� This Is a Master Drawi w ANY NAY TO Sur ANY 6NSTAUAmw. Expires on: � F.B.C. 1. INSTALLAnONS ARE ONLr VAUD EOR DESIGN WIND LOADS AND Max. PANEL LENGTH AS PER SCHEDULES SHOWN ON SHEET 10 OF 15 .040` SOLID/PERFORATED BERTHA AS SAVW EXCEPT TMT PANEL'S LENGTHS FOR ELOOR/CETLWC INSTALLAnONS ALUMINUM STORM PANEL MC41 SHALL BE LIMBED TO 108• T. MR WOOD FRAME CONSTRUCRON: WOOD MEMBERS W BE SOUMERN 11 L E C Q EASTERN METAL SUPPLY, INC p'R PINE No. T• w/SPECIFIC DENSITY OF 0.55 OR Eouv- atm 6157 RaaS Or1Di TRMT TEnm t P71O66L7<Ia11a l:OLRMNY RRSERf aEAOL a M407 02-056 aew ae an1�LI•an.wow n yrw ro.r a rJryRl-Iaf.�r r-ly1 61F11M6 Iw ^ _ ®-OPU6716 rn r wswv rr r m+•+ ru 11NLIER A 1Wr Jr.A E. r wowIl aT 16 nARM Ua NI67 _ MAR 0 ZORL ,p•,i T•UNG LAO - 9arm a r•a c W/ .7V.166 rvlennrKN ,/,•,,r La,e IAC ./11 S J.S 1e7r HOWLmmWAD Saabs a r•a c W wow Pr+ermnav .•'e' EX157WG w/r 1/Y 16r. WOOD RE01M •r m srunwr can WVEIO�•W NFOISI®l +eloElt I SMUMOVI.AQEOINCY PENE1RIrOFEWIM WOWr a ErarelG Wuo e•ncor BM W E CExrwm �FO K NIFMsw 'INWEIf f Br Afffi EREo INAMMO r e 1 �" wow BMW OTO SHWUN N WMANUM m rh nom ain. w/r r 161 n • new a t�, i ` e•ac 1 • .'. 1 C-L roue I I :,r•.�n., � � ; ; { ,� 1 c a1 I �aeae� I roan 1 Ij ; 1 ® I i Cant or usM i FAn�1 I or ® i I �j da'rprc�/111 1 1 or I.1Nmm 1 - -.�asm w�s i C i E MAW IEMMMC CLAW I 2 A- 1 1 1 A 1 I � 7Gxc I I or O CLASS 2'. E I 1 ,/�•/-lad- I 1 7++r I AEoreely I is I WX/M a i i g 519491►IpN ro i I I DEDII T tl 1 Is•a c c Ell1.SW E143S .iw„-•. _i C11 ; I rrj'I T/11•i]/�T 1 7/b'NUI i r[PE T 3 1 InNo NUT o• I I '.a e Q Pi I 1 I 11'CL C 1 Cont 1 T•r s, T•,.' I I 1/.•b'•rQ.l• Gnl. I I 1 MOiM Oo7Y It HAIr I 1 ears W/Y/e'ri AL1EWNgE 1 T•i 6' I AL1OINr1E I Ka!✓m r wN+e.xCxM/r Gi•u r.t acatffFn 1 NM�1a NUr a tEC LOCAtpN Noon oE'ar I LEG tofA7roN 1 � <M�IrrID arar rm Awa f�• --- `�` 114•r i T•IAC £ r. Spalls a r•a c W/ I e/aNT/.•rr..PErenup w K_f MIN CLF PIAIE ;V SCRM 114'0,!'tAC Memy iR11a,Rer!'Ar1Ei.mCLr /H S.S IEs SCREWS•e•a c W/ s. /9LcwWr ears(g OeCYr.S) 114 S.S Nor rrrreraar Ia71NOLTS M1t1 m orrASI*R MAO 1 1/T•er6 PEUEl 111. ., W Q Wnu"'r I MV?ISAO - A w/srEMtK ears(m VIM , AVER ATS a 1°0e�a`p'� - Nara Ar®•r ae+PAsrnrco 0"M WMEOS iSMEereo m(�nwv ys•r WI r r/s'In. "ti. Ar Ircor W /e'Ist/Jr'IIr.0 er/l W I 1 166 I+aFs Ar r'nC!rATIEN♦n a Ll[Nl'SIGEIW/f ear. /ppy (apy : jE'A ENC rUr WALL MOUNTING INSTALLAT/QN5 Ir/I/.� a e•ac SECTIONS f0 r� 1 AND Arali W fitfu ILs ALTERNATIVE 1 IA, ALTERNATIVE f fR racr rw rAm .. N 1/4=1a'1.$,eoElrax ALTERNATIVE 100 AILING & FLOOR MOUNTING INSTALLATIOKS ea,t W/yy+'mmne WAR JW•r i rule� r eErrolrlsL SECTIONS 1 f I 16 �N° I ar Rwu IaEr Nage SGL£:114'- r' � r•ac / so Nar Ar AFAR '/B a T'/MThis Is a Master Drawl WINC NUT O a 6' o Expires on: l -- -- I 1 1 1.WTAUAnONS ARE ONLY VAUD FOR DESIGN WIND LOWS AND Max 1 1 Of ® PANEL 4.ENCR/AS PER SCNEDUIEs SHOWN ON SNEET 10 OF IS PO 1 �EOLVABL£ ExCEPr IMT PANELS UMW FOR FLOOR/CMW INSTAUA11ONS NOW FOR COMBMMnON OF SECRONS: -_ ; i SrNLL BE LaOTEO TO 109' WALL MOUNIINC SECWNS CAN BE COMBINED 1 1 Z. FOR NEW WOOD FRAME WAWWVnOW:WOW MEMBERS TO BE SO—ERN 111N ANr WAr TO SU?ANY MIe/'7 STALU110N. 1 AWE No.Z W/5P£CM7C DENSRr OF aM OR EOUV- r.B.C, i 1 i sEE sNEEr r0 1s FOR CONDJ►pNS REW misrAtulr°N 040" SOUD PERFORATED BERTFGI As shoew .re>•s' \ I OF&4pfNC ONLr APPL/GIBLE TO PANEL M!ORDER 10 ALUMINUM STORM PANEL SrArt ✓v` 1 1 M4NrAW NON POROUS ON.FOR PANEL •--@ KEY HOLE 0 6'O.C. EASTERN METAL SUPPLY, INC ia�r IL ECO imc- DETAIL 2 — INSTALLATION OF A 14 X l" rao ur F13UM a a 001800 CONFAW MW%WAM SM n N0 02-056 SIDEWALK BOLTS ® REMOVABLE PANEL '^`-w° wy1M "" m-aarnw ... o.� .., ... �a.� .m -� iW�eai Il 19mi.A E ' - ear 1.or 15 V a - - s, - i7 1 X 1/4'r:3"14100 LAO 1/�"6,J'LOW LAG ScRm a 6'0.C W/ :L wow"0 5-OL G W/ .. • WAOEIL ErOSRNG 1 I/2'10M BR/C1L VEENER PINEIRM7ON 1' am moo�= n= rNOa� 1NamyE Twit ANCHORS •, � :* O 6'0.0 3 r.-1 is-' I :y, �+'�'• 1 T 1 or® 8 NOV I I 1 (I)t/�-mblIr Ss WOOD STIEW"6OL7 w/ NEARER F14--20+Acrwn REOIBRED T'ANMREDINRD sa"FION 70 vII COyu WOOD ExSlG CLASS REULBW I �—SEIAAAAIION BEfiww/=9O j"Vow"r STEEL Mar UNIELAS AFPUC4BX _ EOMW CIAS I I I251pL161LX BRf/�ss 1 iAA I 1 . i _ap LAOAIN/T u I slrAr qz or or® 0457VX PASSDOTING I A 1 d I nJ1/sUMN ear w/ . BRICK SILL I LI I 11420 JWMff 1 I 3 1 N 2'x,' I 2114' 1 2'. 4- 1 1/4•.-2O:•1/,• I 1 or ® PLAIE 1 r/4•r-m,a/i• I RVDD REUI.1'RED I ea15 w/7/e', 1 AEUI.WED I i I PLATE L 1/u•ee,e Nur e 1 L �1/ I 12•a C 1 1 ., R•a C 1 n 1 1/2•ARM.PENEM41XW >( 007M I W �•�,� I 'SI 1 ^� HASF=0 //,'I-2P X.7/4' 1 1 or 1 A ( Bats N/7/61 W I I !/J2'WIN;Nur erYaa . 1 °• 8Cl r/ra7'acu 111.1. - 2. 5 C..A. r 5 DM.. PANEEw7E 7AOlS ANCHORS a 6'04 w/1/P.-Tau/� ss Ns •: 1 w/1 .-rav�i•u w.s. To E157M PL"V0OO r, //P'r,7-IAC ANO J1L'xeUf rA i 0/1'r,Y IAO iwmw G EX61WG 1 2- Cbm. snlLrt•I'0.G w/ ONtr 7aR PAMEL I • jFcw vS a e'o C w/ owr Ite HAmm r • PLYBO/OO FXISIOYG S BACK SBL . ::: r J/1'Ye.OE PLATE �C /.x/,'NLw OF PLATE 2',,'STLXS J ,q ) 1 w/1/,•r-2Gu/,•ss as V I0011101N PLATE a IIIOmON! HA>E a 16'•O.0 16W REOT ,AS Kyi1pl ANO.NWNO1 OF SEt(r (" o6 fiANDARO AWr FOR Hwa 2JI ALTERNATIVE 13A ALTERNATIVE 13B aL'um 0WE ALTERNATIVE 14 WALL MOUNTING INSTALLATIONS BUILD—OUT INSTALLATION SME: 1/8•- 1' SCALE: 1/8•- I' :I > IN 'ON DETAILS ON TINGB l G NOTE FOR COLRTIFNnON DF SEcnONS ZALIQ FOR PANELS I OR 26 USED JOINTLYThis Is a Master Qrawtng. WALL LKOUNTANG SECTIONS CAN BE COMBINED WITH 1 FOVABIE PANEL9' o ah Expires 7 w ANY NAY TD SUIT ANY WSTALLATTOM • SLY SHEET t0 15 FOR CONOV71016 RC�NYSTALIAIION OF FIASHWO ONLY APPLICABLE TD PANEL TN ORDER TWO MNNTAW NON POROUS fOR PMVEL F.B.C. NOgM: .040'SOUD/PERFORATED BERTHA As SRINN ALUMINUM STORM PANEL 1. INSTALLATIONS ARE ONLY VALID FOR DESIGN HIND LOADS AND Mor. PANEL LENGTH AS PER SCHEDULES SHOWN ON SHEET 10 OF 15 EXCEPT THAT PANEL'S LENGTHS FOR FLOOR/CEILING LNSTALLARONS 1 L ECO 1 N GEASTERN METAL SUPPLY, INC SWL BE UMR£D TO 109' . 420 BEST ROAo6 pmt Z. FOR NEW MOOD FRALIE CONSTRUCTION: WOOD MEMBERS TO BE SOUTHERN faalT «2J6eLIRZ1la'B C-IMF r rmlow BFACrI 7L 2,1AO7 02-05Lvmftw t A•w Ne.eA ►.el;wIM1 m c R wy PINE No.2. W/SPECIFIC DENSRY OF 0.55 LIR EOLM- IA..•I�r �!poen-Itu1 err vs rr err eewi I.R RALUTI A ruff.*.P.E. - • _ 9aEI ID or LS - .. fLMN1 LIt. Hfe7 CITY OF ATLANTIC BEACH r' 800 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 02-00025129 Date 11/05/02 Property Address . . . . . . 1291 99 BEACH AVE Tenant nbr, name RAISE HOUSE 7" Application description . . . MOVING STRUCTURE PERMIT Property Zoning . . . . . . . RESIDENTIAL SINGLE FAMILY Application valuation . . . . 4000 Owner Contractor ------------------------ ------------------------ HIONIDES, CHRIS LARUE HOUSE MOVERS 1291 BEACH AVENUE 315 S . VERMONT STREET ATLANTIC BEACH FL 32233 GREEN COVE SPRINGS FL 32043 (904) 264-1107 ---------------------------------------------------------------------------- Permit . . . . . . MOVING PERMIT Additional desc RAISE HOUSE 7" Permit Fee . . . 100 . 00 Plan Check Fee . 00 Issue Date . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 100 . 00 100 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 100 . 00 100 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. N BUILDING OFFICIAL Nov 04 02 11 : 05a LFIRUE HOUSE MOVERS * SONS 9042848644 P. 2 11/04/2002 07:46 19042410671B TR HOUSE ftuVtKtl PET�uns {tUwG0�40�� PAGE 06 mov 01 02 05:55P RF,CFTN7F T-)) NOV A 4 7002 BY: - 17"arwdaptie Reaoh Boa 9aalooM Road •At nGde ReatI&I Sterid►32273-SNS Pbose: (904)247•5100 • IrAX(904)347-710 • �syanrw.r/ObrtiraUe-beaeh.n.tu BUILDING PFJMT APPLICATION FOR SINGLE-FAMILY OR TWO-FAMILY(DUPL.L7h CONSTRWnOIN MXLUDING MW CbNSTRUCTION,UMJDBL,ADDITIONS AND ALTERATIONS.MOVING OR DEMOLITION) l 1 ' D4TZ L4 JOB ADDRESS �i4mr�2 X "LAf Al1D1tl<5s ��3 '�� ,.r�' ,-C�..r r»oxs: 3 *45 ,, 7 -- ii LEGAL DZSCRIPTION:4LOCK NU)ZI&m.„ LOT NUMZMAZ .ZpN1NG DIST1ICf�� CONTRACTOR P J)D CTATIt UCENSS NUMOM 0.00 B3S '� ��i r i tY1 �y`�� _ PHONE q CITY GtLe& (,$mO. y� STAn •__L.rip FAX PhSCRf9E PROMSID W98 AND WORK TO It IIOn V aiag�iSriaf aim i t PRISEtvT ust OY LAxv OR st=iNG(s) r L,*1 de11 VALUA710N OF PROPMD CONrI' VCTWN !4 O o z' Is ntis a0 additios? KJQ 9 Yet.what are the"' 064 ow ar el.a wed apse: _feet by feet Will rl►a added ate&be bea+cd asd cooled? New eleowel or incrust in service? New ylumbioj fs+nures7 New fneptace?-New boating,i air wadiSoaistt7 Is approval er homeowner s Association os other private e0dtlr Rauited? 3t y a,plume su>)preI with this mppliaaoa. V aLL T IS PROJECT INVOLVE CHANCIS IN ELEVATION,SITE GRADS OA"1ut�tX USIL OF PILI. MA'f N0.. Appliast eerU6es that so caaug,c is site pads or ink instartal wtu tte used on thin project. YIS. See Step 2 hallow, Approval Of tAt Pttbiit Wor6 Department is regvired prior to imsecs Of o IWiWat Permit. PROCEDURE: (Is order to expedite Inuaace of persalts, please f0ow III slept and provids all iorormsdon as soortonriate.) STEP i. V*Afy se.rinm designolen and proper saisc a for Iht pramsed cowinirwsa. If yw an unatro of"infontwtioa,plus soatati the 1+1s►mvy and toning Depar nest{u Do4-247.3817. In order is an oa)y vsrity eanirs designation.pku a have Propery nppmser's !sash Incase hharba a•sibtbie. STEP 3. Cuasmet rhe City of A{ItArfc Bemrh Dafunnant of Pul:fe WQAa to dromm inm it a pro-ganstrustia or poA-teasWAiion vopa8r%0;cs1 stevay cr ttrsdtOS plan Is rsgefrod (If rot requtpttl,Wiser vatpeetiea MM be Provided WO dtit 46plicetloo.)TIAs Depanmen: of !minim WOrtr it iecattd u:1100 Stmdpiptt Lana.Atlanste leach,PL 39231 Telephons:")147.3134 C{A7 Nov 04 02 11 :05a LARUE HOUSE MOVERS * SONS 9042848644 P. 3 1j,/Or/2002 07:46 19042410678 PETRA PAGE 07 mov 01 02 05:55p LANUE HOUbt Muvt"ta STBF). Plems..umit seem Cade A mr,Nveiee 9f Cunvnw owneot,OwaedCmaoaeta AMW&vo U aaaetr is iaaaKtw,ad low(e)completc AM of twoevucYon plroa in dw 6u"itS Depnn+tanl*J"0 laaeod r tbw Adalk Such Ciy HOU,100 Staftwis Rod,Adaarc Owk IrL 32233 Talepltoaa(%*)241•3M 1■aedaies le wimmetim ad-Sib""j detail,pigo.malt cartaut d.X bllawiag Wang a apprgprdau fdr nu typt of work being paforw4d Style a(dmwirip drould be wmtient to depot LII regwind idbinnader,in a eleu and laobk atYner. 1. 4era.n aun.ey sl.o.rina the PMPAY bovad ty With WWiary and dieaaceo and tae leµ1 deurvaolL 1. Loexion a all maeaue$,wroymary ad pem aramL ind6 djeS Wb.KbA,bulldity hey",a$rtleer of$tart"curd eguara(aotW. 'denary any csuelnit swuetates and awL ). lziatias"ar rapoud dtivewmye. �. H P"%4+4 by Of O"vlwm orp4he WorkL a pm-epattu"4 IGycitephlaai lut'Vay. S. Any Siof ant tedvoncamw femrea,including any awI> wins awe1wok CCC),,Wynn water beatc s- lopm-waus Sariim Ona oab:tilatbae. (Swimmko poob my bo alm od from total Imporvbw SYrms.) fhry interntuian za,nay ba oppropriale lbr 1ndiN3val alplicatiaae, 1 HERBSY CBRTWT TEAT ALL. DYUlLD31f�7 S APPLICATION L5 CO"4CT. siGM44mItzOtownt.It DATE._ 11/4/02 __ I RXREOY CLAWY THAT I HAVE READ AND EXAMMZP THIS AFPLICATIQN AND X14OW TPS SAME TO BE TRUE AND COItRSCT. ,ALL FROVISIONS Of TKE LAW$A.ND ORD@IANC-0 GOYSIUM lG TKW TYPE OF WORK W11 bAZ COMPLIED W1T14 WHITMM STECIFIX0 tMRZLN Ort Moor, THE GRANMO OT A PSAMPT DOES nol FUSUYIE TO Gr 1tokU7901UTY TO""LATE OR CANCEL THE tROV1510NS OF An FIDERAL,.SPATE Olt LOCAL RUL1I, REGULATIONS,ORbViA.YCIES,OR LAWS IN ANY MANNER.INCLUDCNG THE GOYFRKING OF CONSTRUCTION OR TIM PERFORMAffCI Of CONSTRUCTION OF TSL FIAOPYRTY. I UNDERSTAND THAT TRZ tSSUAMCE OFTWO lERAIIT IS CONTLNOENT UPOPu THE AEOVE 147ORMATtO N IMG TRIJI AND CORRECT AND T THE TL.ANS AND SUf TWO DATA HAVE BKZK OIL SHALL 01 PROMED AS R6QUIRED- SIGNATURE OF CONTAACTOR DATL L A.DDRRSS AND CONTACT 110VRMATION OS t•ERSON TO RISCZM ALL CORRESPONDENCIt RXGARDING THIS APPLICATION (PLEASX YAlNT) MAME Chris Htonldas MAJLING 40DPMS P. 0. Box 330448 Atlantic $ aachlFL .32293 plforig 241-1151 r$(X 241-0678 g.XAE, SWORN Atm SLtlSCR)7I!<I)86rRORX 14IE THIS DAY OI< ld1?Sl1"`m6e -ago 2 STATE OF FLORIDA,COUNTY OF DL'VAL y rSSGI!)AAS TO OWNELk UYowoed tdentiilcatiom Mrt01 ONi L"S Ty"Of id:atillntioa psodueed eo.ao mw nor taltr esuuect.ett: AS TO CONTRACTOR: Penogally hmv" Ptoduaed identdicelioa Type ofideao&atioapro4wed •W(ycomwAs 10OMAT a.e+or F�iraa OdGbK E•=6 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j � ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 02-00024949 Date 10/09/02 Property Address . . . . . . 1291 99 BEACH AVE Tenant nbr, name . . . . . . WINDOW REPLACEMENT Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning . . . . . . . RESIDENTIAL SINGLE FAMILY Application valuation . . . . 1500 Owner Contractor --------------- --- ----- - ------------------------ HIONIDES, CHRIS VANTAGE CONTRACTING, INC. 1291 BEACH AVENUE 1825-A NORTH THIRD STREET ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 246-6699 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc REPLACEMENT WINDOWS Permit Fee . . . . 40 . 00 Plan Check Fee . 00 Issue Date . . Valuation . . . 1500 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 40 . 00 40 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 40 . 00 40 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. , ( . BUILDING OFFICIAL . lrf�l RECEIVED - =" OCT 3 2002 BY. City of Atlantic Beach - 800 Seminole Road - Atlantic Beach,Florida 32233-5445 Phone:(904) 247-5800 -FAX(904) 247-5845 -http://www/ci.atiantic-beach.fl.us PERMIT APPLICATION FOR REPLACEMENT OF WINDOWS,SKYLIGHTS AND GARAGE DOORS OF SINGLE-FAMILY OR TWO-FAI ULY (DUPLEX) CONSTRUCTION Date L0- 3 O Z Address where work is to be performed ! �ea �'✓� Applicant Gn r' ! Address P �d}� �'.3 a 9l�� /a � r(�eG� Phone: Legal Description: Block Number 3 L/ Lot Number Zoning District eS ` Z— Contractor �PAO-r Aas C9 t"-c P-n C-r q R,S, T State License Number C6 C O 2 2 0 4 Z Address A N9�'-c A `T\A1R,v ST Phone CityAC41L", fSeP,CIQ State L_ Zip 3"LZ56Fax -Z46 -984 y Describe Proposed TTse and Work to be Done V�i tJ Ove i K C-PL-A C1 r%A N'( APPROVED (TY-UF ALLAN I IG BEACH BU1 DING_ OFFICE- i x s� Present Use of Land or Building(s)' C C UpI 4 (Ze S 1 D E IJ C E ISO Valuation of Proposed C.onstructlbn Building Date: - MeanRoof Height (ft) Building (ft) . Building Length (ft) Roof Slope IVIISI *Window Elev. -'S- (ft) Window Height '2 i nt lKi Window Width ft) Measurement from comer of building to window 5' (ft) n . �. h � v � S *Window Eley.From Grade PHONE(407)240-1966-FAX(407)240-8882 STRUCKURAL PERFORMANCE TEST REPORT REPORT NO.: NCTL-210 2065-1 TEST DATE: 07-15-98 REPORT DATE: 07-31-98 EXPIRATION DATE: 07-31-02 CLIENT: Better Bilt Aluminum Products 70412`s Avenue Smyrna,TN 37167 TEST SPECUMN: Baler Bilt Aluminum Product's Series"420"(Type"OXX'J Aluminum Sliding Glass Door. (SGD-05)(Single Glazed)(Steel Reinforced)(with and without sill riser) TEST SPXCIIiTCATIQM AAMA/NW WDA 1I01/1.S-2-97,"Voluntary Specifications for Aluminum Ymyl (PVC)and Wood Windows and Sliding Glass Doors." ZEST SPECIMEN DESCRIPTION GENERAL: The sample tested was a three panel type"OXR"aluminum sliding glass door measuring 15'1-3/4" wide by 8'0-1/8"high overall. The active panel measured 5'0-I/2"wide by Tl I-1/8"high; the fixed panel measured 5'0-7/8"wide by 7-11-1/8"high. Frame and panel members were not thermally broken. Aplastic spacer/guide was used at each panel head/stile corner. The fixed panel was secured to the jamb with two(2)3" long aluminum angle retainers each fastened to the jamb stile with two(2)(#8 x 3/4'1 pan head screws. One claw-type door lock assembly was located at 40"from the bottom of each active panel lock stile each with the keeper fastened and secured to the fixed meeting stile and the right jamb stile at lock position with two(2) screws. One adjustable metal double roller assembly was used at each end of the active bottom rails. The frame was of double screw coped corner construction. Panel comers were of single screw at the bottom rail and double screw at the top rail coped comer construction. The interior vertical sill leg employed an extruded aluminum I- 1/8"high extension;an overall height of 2.03I. One(1)aluminum panel retainer was fastened at 2!1 from the end of each active panel bottom rail. One(1)extruded aluminum female panel adapter was fastened to the fixed panel butt stile with five(5)(#8 x 12")sciews. One(1)extruded aluminum screen adapter was f Lftued to the butt stile using five(5)(4 8 x 1/2")screws. INSTALLAMO-N: The main frame was fastened to the wood test buck using forty-eight(48)(4 8 x 1-112") FHS. (See fastener diagram) REINFORCEMENT: One(1)"U"shaped galvanized steel reinforcing channel measuring 1-3/4"x 3/4"x 1/16"thick filled the length of the panel adapter stile. One(1)'U"shaped galvanized steel reinforcing channel measuring 3/4"x 7/8"x 1/16"thick filled the length of each interlock stile. GLAZING; All panels were channel glazed using 3/16"thick clear tempered glass with a flexible vinyl glazing bead WSTP: Double strips of centerfin.weatherstrip(0270"high)were located at each jamb,stile,lock stile. A double strip of centerfin weatherstrip(0.180"high)was located at each interlock stile. A double strip of centerfin weatherstrip(0250"high)was located at each panel top rail. A double strip of side fin weatherstrip (_430"high)was located at each panel bottom rail. An adhesive back polypile dust plug measuring 1-3/16"x I3/16"x 0.420"was located on the head and sill at each end of vertical stile exterior track PROFESSIONALS IN THE SCIENCE OF TESTING i WEEPS: One weep notch measuring 1-1t2"x leg height was located at each and of each ofthe interior sill roller leg,exterior sill roller leg and the screen sill roller leg. MUMMIR&WOMMLORS GE FROM: Non painted aluminum, MAL=: Frame and panel bottom rail corners were sealed with a smalljoint sealant SCREEN: Two(2)insect screens,one center insect screen measuratg 5'0-14,wide by 7'11"high; Both were of coped type corner construction. The screen employed fiberglass mesh cloth with a hollow vinyl spline. One roller assembly was located at each end of the bottom rads. One(1)claw-type lock assembly. TEST RF.-S ala PARAGRAPH NO. iff"OF T E MEASUM ALLOWED 2.2.I9.5.1 Operating Force Center Active Panel To Open 20#max. 30# In Motion 5#max. 20# Right Active Panel To Open 18#max. 30# In Motion 3#max. 20# 2.1.2 Air Infiltration 1.57 psf(15 mph) Pass 0.30 CFM/F14 2.1.3 * Water Resistance-5.0 GPH/FTZ WTP=4.50 psf No Entry No Entry 2.1.4.2 Uniform Load Structural 45.0 psf exterior 0.245" 0381" 45.0 psf interior 0.258" 0381" 2.2.19.5.2 Deglazing Center Active Panel Top Rail (50#) 10.2%(0.051 <1000/0 Bottom Rail (509) 7.8%(0.039") <100% Left Stile (70#) 6.0%(0.030") <1000/0 Right Stile (70#) 5.401a(0.027") <1000/0 Right Active Panel Top Rail (50#) 8.40/.(0.042'1 <100'/0 Bottom Rail (509) 8.4%(0.042") <100% �. Left Stile (70#) 8.0%(0.040' <100% Right Stile (70#) 6.2%(0.031") <100% r Better Bilt Aluminum Products -3- NCTL-210-2065-1 OPTIONAL PERFORl12A1�iCE 5 4.3 * Water Resistance-(S.o GpMF r2) WTP=5.25 psf No Entry ( No Entry Note: At this point in testing an additional sill riser was attached to the existing main sill's interior vertical leg. The following results were obtained: 4.3 * Water Resistance-(5.0 GPII/FT) WT?-6.00 psf No Entry No Entry 4A.2 Uniform Structural Load 52.5 psf exterior 0.379" 0381" 52.5 psf interior 0.380" 0.381" TEST COMPLETED: 07-15-98 *Test performed with and without insect screen. Note: In addition,Better Bilt Aluminum Products'Series"430"and"440"also receive an SGD-C35 rating being identical in panel construction and interior sill heights. This test specimen meets the performance criteria level of SGD-C35 of the AAMA/NWWDA/101/I.S.2-97 specification. Detailed drawings were available for laboratory records and compared to the test specimen at the time ofthis report. A copy of this report along with representative sections of the test specimen will be retained by NCIL for a period of four(4)years. The results obtained apply only to the specimen tested ID NAL CER TED TEST'Il�iG ` ABORAT0 INC - I L E.LANE ' Y f Manager Y J ti- 1VIEV rte, CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 80Q SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247.5877 PERMIT INFORMATION LOCATION INFORMATION _ Permit Number: 24280 Address: 1291 BEACH AVENUE Permit Type: REMODELING ATLANTIC BEACH, FL 32233 Class of Work:-ALTERATION Township: Range: Book: Proposed Use: SINGLE FAMILY, Lot(s): Block: Section: Square Feet:. Subdivision: ATLANTIC BEACH Est. Value: 6,500.00. Parcel Number: Improv. Cost: 1,800.00 OWNER INFORMATION Date Issued: 6/17/2002 Name:' -_ HIONEDES, CHRIS Total Fees: 38.00 Address: 1601 BEACH AVENUE Amount paid: 38.00 ATLANTIC BEACH, FL 32233 Date Paid: . 6/17/2002 Phone: (000)000-0000 Work Desc: REPLACE WINDOWS ON PORCH CONTRACTORS ;..-L APPLICATION FEES VANTAGE CONTRACTING,INC. #tom , 38.00 NOT. ; • .� rr . ION BUILDING MATE SPACE,AND MUST BE CLEAR V' .FAILURE TO CO =,]j■`y THE PROPERTY OWNS c , ISSUED ACCORDING TO ASUBJECT TO REVOCATION FOR VIOLATION OF APPLICAB u/ 6/18 02 41 "i:0 CDraer: 1 . 66262 .ATLANTIC BEA04 BUILDING DEPT.. 14 PE111=49I1,DIIS' 1 0.00 0010N03221010 1291 BEAM CI CEW 3223 538.00 foam date: 6/18/02 Ties: 15:07:42 CITY OF ATLANTIC BEACH PERMIT .CALCULATION SHEET Address �ZQ 2>eyacVA ()L/c Date Heated Sauare. Footage @ $ per sq .ft = $ Garage/Shed -_ @a er s ft = $ P Carport/Porch @ $ per sq ft = $ Deck _@ $ per sq ft . = $ Patio _ @ $ per sq ft $ v� TOTAL VALUATION: Total Valuation 1st $ ©a Remaining Value $ per thousand or portion thereof TOTAL BUILDING FEE $ S� + 1/2 Filing Fee $ ( ) Fireplaces @ $15 . 00 $ BUILDING PERMIT FEE $ WATER IMPACT FEE $ SEWER IMPACT FEE $ WATER METER/TAP $ CAPITAL IMPROVEMENT $ SEWER TAP $ ( ) RADON (HRS) . 0050 $ SECTION H PAVING ( ) $ HYDRAULIC SHARES $ CROSS CONNECTION $ ( ) SURCHARGE 0050 $ OTHER $ GRAND TOTAL DUE $ ADDITIONAL PERMITS OR FEES : Mechanical Plumbing Electric/New Electric/Temp ; SwimmingPool Septic Tank Well Sign Finish Floor Elevation Survey Other CALCULATIONS and/or NOTES : RECEIVED Q O NG \L�` vted i QQ1. ����i��ylrf�c�. C-,.+ t � � P('sn'�, •�`� �' -sem -y o, AtlanticCoach and '? City of Atlantic Beach • 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Phone:.(904)247-5800 • FAX (904) 247-5845 •h=://www/ci.atlantic-beach.fl.us PERMIT APPLICATION FOR REPLACEMENT OF WINDOWS,SKYLIGHTS AND GARAGE DOORS OF SINGLE-FAMILY OR TWO-FAM11Y(DUPLEX) CONSTRUCTION Date . ©?i • Address where work is to be performed. Applicant_ �►t`� �C.A/1 I✓r.�7 Address !zv* '�• t�. . ,.'Wi*hone: Legal Description: Block Number Lot Number 12o Zoning District • Contractor e License N mbea-ACy'G G0Cso Address I �_ % ��' Phonelp�[ . cityG- State _Zip Fax Describe Proposed Use dd Work to be Present Use of Land or Building(s)' 7( � � Valuation of Proposed Construction I � Building Date: ? //,,,, Mean Roof Height (ft) Building width�(ft) Building Length (07-(J/ (ft) Qti l� I 1 l Roof Slope *Window Elev. _(ft) Window,Height Window Width Measurement from comer of building to window Ss *Window Eley.From Grade �o \ Yo, From: BetterBilt 6-10-02 3:93pm P. 2 of 3 Better Bilt Doors and Windows 650 west Market St. -Gratz, PA 17030-0370-Phore(717) 365-3300-Fax (717) 365-3480 BetterB�it� APPROVED DOORS AND wnvDOws CITY OF ATLANTIC BEACH BUILDING OFFICE SPECIFICATIONS JUN 17 2002 740 ALU'VIINUM SINGLE HUN GW N Y MAIN FRAME - Head, jamb, and sill shall be made of aluminum alloy 6063-T5 extrusions, with a nominal wall thickness of.055". Frame depth shall be 2", available with 1-3/16' nail-fin set-back or X,"front flange. Frame to be assembled with two#8 screws per corner. SASH — All upper fixed sash and lower operating sash members shall be made of extruded aluminum alloy 6063-T5 with a nominal wall thickness of .050". One screw fastener per comer shall be used to assemble sash. Operable sash shall be of tilt design and removable without tools. Fixed sash to be removable and secured with screw fasteners. GLAZING— Fixed and operating sash shall be marine glazed with a flexible PVC wraparound. Single pane or %s' insulated glass to be available. Insulated units to be available with decorative grids between the glass and single glazed units to be available with decorative, interior mounted, grids to be secured in an easily removable spring-loaded subframe. WEATHERSTRIPPING- Single strips of polypile type weatherstrip shall be installed at all frame contact points of operating and fixed sash. HARDWARE — Operable sash mechanism to consist of factory tensioned spiral balances. Cam latch to be zinc die-cast and affixed at top rail of operating sash to engage the meeting rail of the top sash. All screws, clips, springs, and other hardware items to be made of corrosion resistant materials compatible with aluminum. SCREEN — Half screen frame to be made of roll-formed aluminum. Screen cloth shall be made from 18x16 fiberglass mesh and held secure by flexible, vinyl spline. Screens meet ANSI/AAMA standard 1004/87. (NOTE: Insect screens are intended only to provide reasonable insect control. They are not intended to prevent people or objects from exiting the window or to provide security against forced entry.) INSTALLATION - Done by others. Frames should be Installed straight, plumb and level without twisting, bowing or springing. Manufacturer's recommended installation instructions are to be used. Installer should make final adjustments to ensure proper sash operation and window performance. PERFORMANCE - Meets or exceeds the requirements of AAMA 1011I.S. 2-97. This window is also certified by AAMA and carries the AAMA certification label. Better Silt Doors and Windows is a division of MI Home Produrls,Inc. NOTE: MI Home Products'designs and manufacturing methods are continually being imprcved. Due tc this and other factors,we reserve the right to change specifications without notice. It is the sole resporsibiliiy of the purcnaserhristaller to be sure that the intended u:-e of this product complies with an,and all applicable buildings codes (i.e. egress, safety glass near coorways, etc.) If you require further tecnnicai infcrmaiien regarding the pioduct please corlact;rout ielailerlsalesman Rpv.5-10-20(x) To. From: BetterBilt 6-10-02 3 31p p. 2 of i AAMA/NWWDA 101/I.S.2-97 TEST REPORT SUMMARY Rendered to: MI HOME PRODUCTS,INC. SERIES/MODEL: 7401744 TYPE: Aluminum Single Hung Window with Nail Fin Title of Test Results Rahng H R45 52x72 Overall Design Pressure 45 psf OpamtiM Force 24 lb max. Air Infiltration QAQ c Water Resistance 6.75 psf Structural Test Pressure +67.5 psf -70.8 pef D Passed Forced Eptg Resistance Grade 10 Reference should be made to Report No. 0140351.03 for complete test specimen descriptipn an4,. data. For ARCHITECTURAL TESTTNO,INC. --off .� • � � r s Mark A. Hess Technician eT A. MARbaw ^•....�•' C��,'• FEdRuA,e lTo: Fro&: BetterBilt 6-10-02 3.31pm P. 3 o 7 r Architectural Testing AAMAINW WDA 101/1.5.2-97 TEST REPORT Rendered to MI HOME PRODUCTS,INC. P.O.Box 370 Gratz,Pennsylvania 1 703 0-03 70 Report No: 01-40351.03 Test Dates: 10/22/01 And: 10/23/01 Report Date: 02/15/02 Expiration Date: 10/23/05 Project Summary: Architectural Testing, Inc.(ATI)was contracted by MI Home Products, Inc. to witness performance testing on a Series/Model 740/744,alurninum single hung window at MI Horne Products, Inc.'s test facility in Elizabethville, Pennsylvania. The sample tested successfully met the performance requirements for a H-R45 52 x 72 rating. Test Specification: The test specimen was evaluated in accordance with AAMA/NWWDA 101/I.S.2-97, Voluntary Specificationsfor Aluminum, Vinyl(PVC)and Wood Windows and Glass Doors. Test Specimen Description Series/Mod el: 7401744 Type: Aluminum Single Hung Window With Nail Fin Overall Size: 4'4-118" wide by 5' 11-5/8"high Active Sash Size: 4' 2-3A" wide by T 11-5/8" high Fixed Daylight Opening Size: 4' 1-118" wide by 2'9' high Screen Size: 4' 1-7/8" wide by 2' 11-5/16"high Finish: All aluminum was polished Glazing Details: The active sash and fixed lite were glazed with one sheet of 1/8" thick clear tempered glass. Each sash was channel glazed using a flexible vinyl gsitalt"•,a, Ar 130 Derry Court II�`•� ^�•••�•�N�••�.�����, York,PA 17402.9405 phone:717.764.7700 fax: 717.764.4129 www.testati.com i �s fEea�.oay woe} To From; BetterBilt 6-10-02 3:31pm P. 4 of 7 01-40351.03 Page Page 2 of 4 Test Specimen Description: (Continued) Weatherstripping Description Quanti Location 0.330"high by 0.187" 1 Row Fixed meeting rail interlock backed polile with center-71n. 0.170" high by 0.187" 1 Row Fixed lite,stiles and top rail backed polypile with center fin 3/8" diameter hollow 1 Row Bottom rail bulb gasket 0.310" high by 0.187" 1 Row Active sash stiles backed polyptle with center fin 0.150' high by 0.187" 1 Row Active sash stiles wide polypile Frame Construction: All frame members were constructed of extruded aluminum with coped, butted and sealed comers fastened with two screws each. Fixed meeting rail was secured utilizing one screw in each end directly through exterior face into jamb. Silicone was utilized around exterior meeting rail/jamb joinery. Sash Construction: All sash members were constructed of extruded aluminum with coped and butted corners fastened with one screw each. Screen Construction: The screen frame was constructed from roll-formed aluminum members with plastic keyed comers. The screening consisted of a fiberglass mesh and was secured with a flexible vinyl spline. Hardware: Description 09AIW Y Location Plastic tilt latch 2 One each end of the interior Meeting rail Metal sweep lock 2 13" from meeting rail ends Ralarice assembly 2 One per jamb Screen tension spring 2 One ger end of screen stilet` V •, L, Tilt pin 2 One each end of bottofi 'al�.•'�"++rt'�r'• �. ti ter, ♦,�T'�R••��.',�• f_',•Sir+..►..SM• To: From; BetterBilt 6-1.0-02 3:31pm P. 5 01: 7 01.40351.03 off Page 3 of 4 Test Specimen Description: (Continued) Drainage: Sloped sill Reinforcement: No reinforcement was utilized. Installation: The test specimen was installed into the 42 2 x 8 Spruce-Pine-Fir wood buck with 1" galvanized roofing nails through the nail fin every 8" on center. Polyurethane was used as a sealant under the nail fin and around the exterior perimeter. Test Results: The results are tabulated as follows: Parauph Title of Test-Test Method Results Allowed 2.2.1.6.1 Operating Force 24 lbs 30 lbs max. Air Infiltration(ASTM, E 283) @ 1.57 psf(25 mph) 0.10 cfiniftz 0.30 cfin/fe max. Note !#l: The tested specimen meets the performance levels specified in AAAV.NWWDA 101119, 2-97 for air infiltration. Water Resistance(ASTM E 547-96) (with and without screen) WTP—6.75 psf No leakage No leakage 2.IA.i Uniform Load Deflection ger ASTM E 330 (Measurements reported were taken on the meeting rail) (Loads were held for 52 seconds) 15.0 psf(positive) 0.86"* 0.29"max. L 15.0 psf(negative) 0.8111* 0.29" max. *Exceeds L/175 for deflection, but meets all other test requirements. 2.1.4.2 Utriform Load Structural per ASTM E 330 (Measurements reported were taken on the meeting rail) (Loads were held for 10 seconds) 22.5 psf(positive) 0.01" 0.20" max. v 22.5 psf(negative) <0.01" 0.20" max. 2.2. .6.2 Deglazing Test per ASTM E 987 Iii operating direction at 701bs Top rail 0.06"l12% 0.50"/100% Bottom rail 0.06"!12% 0.50"/100% "' ''•r.,, In remaining direction at 50 lbs Left stile 0.03"!6% 0.50�200%" !tight stile 0.03"/6% 0.x'1 D00% 2OIL From: BetterBilt 6-10-02 3;31pm p. 6 of 7 01.03 Pap 4 Page 4 of 4 Test Results: (Continued) Paraeranh Title of Test-Test Method Results Allowed 2 .8 Forced Entry Resistance per ASTM F 588-97 Type: A Grade: 10 Lock Manipulation Test No entry No entry Test Al thru A5 No entry No entry Test A7 No entry No entry Lock Manipulation Test No entry No entry Qptional Performance Uniform Load Deflection per ASTM E 330 (Measurements reported were taken on the meting rail) (Loads were held for 52 seconds) ��X , 45A psf(positive) 0.91"* 0.29" max. ;�45.0 psf(negative) 0.97"* 0.29"max. "Exceeds L/175 for de/lection, but meets all other test requirements Uniform Load Structural per ASTM E 330 (Measurements reported were taken on the meeting rail) (Loads held for 10 seconds) 2 67.5 psf(positive) 0.14" 0.20"max. d 67.5 psf(negative) 0.19" 0.20"max. a 70.8 psf(negative) 0 20" 0.20"max Detailed drawings, representative samples of the test specimen, and a copy of this report will be retained by ATI for a period of four years. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the above referenced specification. This report does not constitute certification of this product, which may only be granted by the certification program administrator. For ARCHITECTURAL TESTING,INC: Mark A. Hess Allen N. Reeves, P.E. ���•, Z� 3:• t�� �i�,f Technician Director-Engineering Sc .••A""' MAF L•baw 01-40351.03 2 S'1 •s A T S'A ' _ To From BetterBilt 6-10-02 3,37pm p. ? of 3 MI HOME PRODUCTS - PRIME ALUMINUM WINDOWS - INSTALLATION INSTRUCTIONS FOR "NAIL FIN" PRODUCTS MI Home Products appreciates your recent purchase of a maintenance free prime window, which will not rust, rot, mildew, or warp. This is a quality product that left our factory In good condition — proper handling and installation are just as important as good design and workmanship. Please follow these recommendations to allow this product to complete its function. 1 Handle units one at a time in the closed and locked position and take care not to scratch frame or glass or to bend the nailing fin. 2. Set unit plumb and square into opening and make sure that there is 3/16" + 1/16" clearance around the frame. Fasten unit into opening in the closed and locked position, making sure that fasteners are screwed in straight in order to avoid twisting or bowing of the frame. Make sure that sill is straight and level. Check operation of unit before any and all fasteners are set. 3. Use # 8 sheet metal or wood screws with a minimum of 1' penetration Into the framing (stud). Place first screws (two at each corner) 3" from end of fin. For positive and negative DPs (design pressures) up to 35,do not exceed 24"spacing of additional screws. For ON from 35.1 to 60, do riot exceed 18". Install load bearing shim adjacent to each anchor. Use shim where space exceeds 1/16". 4, Flash over head and caulk outside perimeter in accordance with code requirements and good installation practices. 5 Fill voids between frame and construction with loose batten type insulation or non-expgndinq aerosol foam specifically formulated for windows and doors to eliminate drafts. The use of expanding aerosol type insulating foam,which can bow the frame,waives all stated warranties. 6, Remove plaster, mortar, paint and any other debris that may have collected on the unit and make sure that sashivent tracks and interlocks are also clear. Do not use abrasives, solvents, ammonia, vinegar, aikakne, or acid solutions for clean-up, especially with insulated glass units as their use could cause chemical breakdown of the glass seal. Take care not to scratch glass; scratches severely weaken glass and it could eventually break from thermal expansion and contraction. Clean units with water and mild detergent as you would you automobile. CAUTION - MI Home Products or its representatives are unable to control and cannot assume responsibility for the selection and placement of their products in a building or structure in a manner required by laws, statutes, and/or building codes. The purchaser is solely responsible for knowledge of and adherence to the same. MI Home Products window products are not provided with safety glazing unless specifically ordered with such. Many laws and codes require safety glazing near doors, bathtubs, and shower enclosures. Also be aware of emergency egress code requirements. Corporate Headquarters: ' ` . ,,., � ••.',.- ,1f .,+c 650 West Market St. �> „ Gratz, PA 17030-0370 . ' , ►�� T �^ ; (717)365-3300 n f l;, F 4 ` y m r i r � eYQ II ..�.. �. • � �eaw r f PETRA MANAGEMENT, INC. PMI Licensed Reai Property Manageme � (���O P. O. Box 330448 J -1151 Atlantic Beach, FL 32233-0448 C�.��.-� .0628 SNA CORNERSTONE OF City of Atlantic Beach , : . 800 Seminole Road Atlantic Beach, Florida Attn: UonXoW bkAA/ )<O Re: Window Replacement w/Wind Born Debris Shutters V� 1291 Beach Avenue d Atlantic Beach, Florida 32233 Dear Don: l Please find the attached Dwg # 1/1 (6-3-02) which details the proposed design/installation of wind born debris shutters and the single hung aluminum replacement windows (see MFR. Statement of Compliance). We hope this will resolve product compliant issues and allow for the issuance of a building permit. Thank you Greg Mills RECEIVED QIt,Y Of Ati011tiC Seach O l'IdI g, and Zoning Ian 30 02 11 : 31 Building Department 904-247-5805 / p. l REcEp ED Ft;�: , yAt1 4, RE-C EIVED City of Atlantic Beach• 800 Seminole Road- Atlantic Beach,Florida 32233-5445 1, �, Phone: (904)247-5800- FAX (904)247-5805• http://www/ci.ntlantic-beach.H.us v UN 3 PERMIT APPLICATION FOR REMODEL,ADDITIONS AND ALTERATI* 0f Atlantic Beach MOVING OR DEMOLITION OF SINGLE-FAMILY OR TWO-FAMILY (DUPLEX) C6 lonin �n�'"_ i, DATE_�vz�j-OvL APPLICANT. _ x,,11f m S rt l UY11 e S _ ADDRESS J G I J�f tn P'S`C t PHONE: 241- 1151 ADDRESS WHERE WORK IS TO BE PERFORMED .�q Q-,Q�� ATe /� �'C. &Och LEGAL DESCRIPTION, BLOCK NUMBER�_ LOT NUMBERj_ ZONING DISTRICT CONTRACTOR STATE LICENSE NUMBERCOGC U.QjLL12 ADDRESS I PHONE ( --to 6 G 9 CITYf r SUyll ReOC STATE r-ti.G_ 7.IP CSU FAX - O?C�GI DESCRIBE PROPOSED USE AND WORK TO BE DONE PRESENT USE OF LAND OR BUILDING(S) h� VALUATION OF PROPOSED CONSTRUCTION ` — 9' ©t lr�F-a- Is this an addition? If yes,what are the dimensions of the added space: feet by feet Will the added area be heated and cooled? New electrical or increase in service? New plumbing fixtures? New fireplace? New heating/air conditioning? Is approval or Homeowner's Association or other private entity required? If yes,please submit with this application. PROCEDURE: (In order to expedite issuance of permits, please follow all steps and provide all information as apairoariate.) STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information,please contact the Planning and Zoning Department at 904-247-5817. In order to correctly verify zoning designation,please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Please submit Energy Code Forms, Notice of Commencement, Owner/Contractor Affidavit if owner is contractor, and four(4)complete sets of construction plans to the Building Department, which is located at the Atlantic Beach City Hall, 800 Seminole Road,Atlantic Beach,FL 32233 Telephone:(904)2117-5826 01t01J02 ' :tan 30 02 11 : 31a Building Department 904-247-5805 p, 2 In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures, temporary and permanent, including setbacks, building height, number of stories and square footage. Identify any existing structures and uses. 3. Existing and/or proposed driveways. 4. If required by the Department of Public Works,a pre-construction topographical survey. 5. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 6. Impervious Surface area calculations. (Swimming pools may be excluded from total Impervious Surface.) 7. Other information as may be appropriate for individual applications. I HEREBY CERTIFY THAT ALL INFORMATION PROVIDED WITH THIS APPLICATION IS CORRECT. SIGNATURE OF OWNER DATE 14 `1... I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH,WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL,STATE OR LOCAL RULES, REGULATIONS,ORDINANCES,OR LAWS IN ANY MANNER,INCLUDING THE GOVERNING OF CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION OF THE PROPERTY. I UNDERSTAND THAT THE ISSUANCE OF THIS PERMIT 1S CONTINGENT UPON THE ABo'vE INFORMATION BEING TRUE AND CORRECT AND THAT THE PLANS AND SUPPORTING DATA HAVE BEEN OR SHALL BE PROVIDED AS REQUIRED. SIGNATURE OF CONTRACTOR /`/ DATE 2 ADDRESS AND CONTACT INFORMATION OF PERSON TO EIVE ALL CORRESPONDENCE REGARDING THIS APPLICATION (PLEASE PRINT) NA1lIE ���� n/ MAILING ADDRESS G�­T � PH ONE q64r (- i-Jq z- FAx 24 1— SWORN SWORN AND SUBSCRIBED BEFORE LME THIS DAY OF \V)�-u(:' )Z U STATE OF FLORIDA,COUNTY OF DUVAL 1 NOTARY'S SIGNATURE J ASTRops --� Personally known TTY WALLACE ❑ Produced identification y Comm Exp,12/17/04 Type of Identification produced BUC No.CC 988757 PersawtY K Woo I)Dow I.D. AS TO CONTRACTOR: ---f] Personally known ❑ Produced identification 'RPATTY p� PATTY WALLACE Type of identification produced auBUC > My Comm Exp.12/17/04 01/02/02 No.CC 988757 Personally M. I 1 Other I.D. l-1IiZol , - - i - -- a, - n a _ l ii I col , y co '00 — _ - --GftMer L- THIS FENESTRATION PRODUCT COMPLIES * WITH THE NEIN FLORIDA BUILDING CODE FOR RESIDENTIAL BUILDINGS WITH "�4 RQ F r Q I1 q■ HEIGHT OF 30 FT. OR LES POSUREo i (WHICH IS INLAND OF A LI . FROM THE COAST), AND WALL ZONE 115" (INSTALLED NEAR THE CORNER OF THE BUILDING). PER ASTM E1300, THE CORRECT GLASS THICKNESS, BASED ON THE NEGATIVE DESIGN PRESSURE (DP) LISTED BELOW, HAS BEEN INSTALLED IN THIS UNIT. I THE GLASS THICKNESS IS BASED ON IT'S WIDTH, HEIGHT, AND ASPECT RATIO. i WIND ZONE: 140 MPH OR LESS DESIGN PRESSURE (DP):+ 35.31 - 47.2 THIS PRODUCT MEETS THE REQUIREMENTS FOR STRUCTURAL LOADS, WATER AND AIR INFILTRATION PER ATTACHED AAMA PERFORMANCE LABEL. BE ADVISED THAT IF LOADS ARE PLACED UP TO OR EXCEEDING THE TESTED LEVELS, THIS PRODUCT MAY BE ALTERED IN SUCH A WAY THAT FUTURE PERFORMANCE WILL BE REDUCED. * COMPLIANCE MUST INCLUDE INSTALLATION ACCORDING TO MANUFACTURER'S INSTRUCTIONS AND FLORIDA CODE REQUIREMENTS. MI HOME PRODUCTS, INC. MIP.466 CITY OF { r4&"4 e Veacl - -;7eanida SOO SEMINOLE- ROAD \I l..\\TIC 11FACH. IT(WID:\ - -- - — — --- - -rEI-I:PHO\Ii 004- -14 -i8Q() DATE/�r '9-9 JEA Construction & Maintenance 2325 Emerson Street Jacksonville, FL 32207 Attention: Connie Re: Final Electrical Inspections Dear Connie: Final Inspections on the following locations have been completed and approved: PERMIT NO. y o 1 drJ 7 os�(MD �w� DC ZNp c CD -i 0D dF ' mmm3 ,ry m `°D c Z � cc s7 a d CL o CD a. c r co-n n V m ' m ° O 1 N �O n M M M m ❑n❑ n D O o m Please ca a o w_3 m `D 0 7 -9 In 0 CD 70 o O C = to M -i � a N to 'n O ❑on � 0 q D z v m O n „ cn-I 7J A T y CD F = E 3 " EPARTMENT �� 3 0 o `° D i z "Il d T ❑ ❑ 7 7 n U` A � c C ❑ m D m �ca D Cr i V u� Z n CITY OF I c Office of Building Official 1 REQUEST FOR INSPECTION . Date / °� Permit No. /Y3 Time A , ?eceived (P M Job Address 4ocality Owner's Name af.� I /� r o n_t eS_Contractor BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing ❑ Footing ❑ Rough Wiring ❑ Rough ❑ Air Cond. & ❑ Re Roofing 7 Slab ❑ Temp Pole ❑ Top Out ❑ Heating Insulation ❑ Lintel ❑ Final Sewer ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION Mon. Tues. Wed. Thurs. Friday &QiP.M. A.M. Inspection Made P.M. Inspector Final Inspection Cf],00" Certificate of Occupancy ❑ �3�1 Date CITY OF ATLANTIC BEACH MECHANICAL PERMIT 800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247-5877 PERMIT INFORMATION LOCATION INFORIYIATION Permit Number: 18410 Address: 1291 BEACH AVENUE Permit Type: MECHANICAL ATLANTIC BEACH, FL 32233 Class of Work: ALTERATION Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: ATLANTIC BEACH Est. Value: Parcel Number: Improv. Cost: OWNER INFORMATION Date Issued: 6/23/1999 Name: HIONEDES, CHRIS Total Fees: 41.00 Address: 1601 BEACH AVENUE Amount Paid: 41.00 ATLANTIC BEACH, FL 32233 Date Paid: 6/23/1999.- Phone: (000)000-0000 Work Desc: REPLACE HEAT PUMP AND AIR HANDLER CQITRATOR S) CA=T'ION FEE'S A COMFORTABLE ENVIRONMENTAL PERMIT 41.00 FINAL __ Inspections.Reggired. NOTICE-INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDINGS IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. 'x41.68 14 C,— Date: 6/23/99 81 Receipt: 88b6973 266 ,ATI-ANTIC BEACH BA ILDING DEPT. CHECKS .,,ot3221888 BUILDING AND ZONING INSPECTION DIVISION CITY OF ATLANTIC BEACH All-AtIrlC nEACII, FLOTIMA 32233 APPLICATION 6=01z MECHANICAL PERMIT CALLTN NUMBER IMPORTANT -- Applicant to complete all ifems in sections I, II, III, and IV. FSI,,,,lAddss .lz � J d-e4CA AU -eLOCATIOPJre _ — — Or- InfortocEng Slreels: f1nl—,,m Z T A , And v (/-- BUILDING Sub di.is;on II. IDENTIFICATION — To Ise compleled by all applicanls In cons;doral;on of per-il gi en for doing the worl as described in the ahc— slaleo...I we hereby acjren In rarlonn %aid work in accordance with the allaclwd plans and spe i(,caGons wl,;ch are a marl hernol and ;n accordance —1h the Cily of Jarkon,ille ordinances and sfandards of good praclice Iisled Iherein. Name of Mschenicel / 1 [ Contractors Con}ratlor tPrin}t ( UM YG�T�UJC C{AJ 11A.IeMarler ///r� v� bLf, t� Nemo of 1� Property Owner Signoture of Owner J Signelure of or Aulhorued Agent Architect or Eng;near Ill. GENERAL INFORMATION A' Ty of heel;ng fuel: �• IS OTHER CONSTRUCTION BEING DONE ON 7H1clik 111IS BUILDING OR SITE 1 ❑ Got —❑ LP ❑ Nelurel ❑ Conlral Wilily IF YES, GIVE NUMBER OF CONSTRUCTION ❑ Oil PERMIT Ofh�r — •cif ��f�l�t i " CITY OF ATLANTIC BEACH Oak^ V j DEPARTMENT OF BUILDING 800 Seminole Road -Atlantic Beach, FL 32233- Tel: 247-5826 - Fax: 247-5877 ELECTRICAL PERMIT PERMIT INFORMATIONLOCATION INFORMATION Permit Number: 18384 Address: F ff= BEACH IAVE Permit Type: ELECTRICAL ATLANTIC BEACH, FL 32233 j Class of Work: REPAIR Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: ATLANTIC BEACH Est. Value: Parcel Number: i Improv. Cost: OWNER INFORMATION Date Issued: 6/16/1999 Name: HIONEDES, CHRIS Total Fees: 25.00 Address: 1601 BEACH AVENUE Amount Paid: 25.00 ATLANTIC BEACH, FL 32233 Date Paid: 6/16/1999 Phone: (000)000-0000 Work Desc: ESS150AMPS1 PH3W240V1-1/2"RW- REPLACED METER JAWS AND AC M#24-406-540 CONTRACTORS APPLICATION FEES i DAVID T. COOK PERMIT 25.00 i i r 0 � FINAL ELECTS 3` 1 Ins ctlons:Required L NOTICE - INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. i LCDate: 6/15/99 81 Receipt: M64975 AR EACH B 0 1LDING T. 8818888321888 j CITY OF ATLANTIC BEACH, FLORIDA Approved by APPLICATION FOR ELECTRICAL PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE:- ) _ 19� IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. , 949 (� t - �oG ELECTRICAL FIRM: MASTER ELE /RICIA¢� R BOX- BLDG. SIGNA URE /'Q�/� , ' ! /' _ . U� NAME ADDR- BLDG.SIZE �� BETWEEN: RES. (`l' APT. ( ) comm. ( ) PUBLIC ( ) I DUS. ( ) NEW ( ! OLD ( ) REW. ( ) ADDITION ( ) TRAILER ( ) TEMP. ( ) SIGNS ( ) SQ. FT. SERVICE: NEW( ) INCREASE ( 1 REPAIR ( ) FEE _ CONDUCTOR SIZE AMPS COPPER ( ) ALUM. SWITCH OR BREAKER AMPS PH W ��////ffVOLT ACEWAY I EXIST.SERV.SIZE AMPS PH W 4 OLT RACEWAY FEEDERS NO. SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.90 AMPS. 31.100 AMPS. - SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 4.100 AMPS. OVER APPLIANCES BELL TRANSF. AIR H.P. RATING H.P. RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 0.1 OVER MOTORS H.P. VOLTAGE PHS NO. 1 N.P. VOLTAGE PHS MISCELLANEOUS Cf'" cge'd G TR AA1¢FnRMGRS• I11UnFR Ann v nvFR Ann v CITY OF 1*&4tz. e Fead - B uda 800 SEMINOLE ROAD IF � ATLANTIC BEACH,FLORIDA 32233-5445 Au 2, 1996 TELEPHONE(904)247-5800 FAX(904)247-5805 SUNCOM 852-5800 TO: JACKSONVILLE ELECTRIC AUTHORITY ARD CC2 21 West Church Street Jacksonville, FL 32202 PLEASE BE ADVISED THAT THE FOLLOWING ADDRESS HAS BEEN CHANGED: Old Address New Address 1299 Beach Avenue 1291 Beach Avenue 1299-1 Beach Avenue 1299 Beach Avenue Number 1291 Beach Avenue should be the house facing the ocean and 1.299 should be the cottage facing Beach Avenue. NOTE TO JEA: The electric meter for 1291 Beach Avenue is #35294656 (main residence facing ocean) and the electric meter for 1299 Beach Avenue is #46839963 (cottage) PLEASE AMEND YOUR RECORDS ACCORDINGLY. S CERELY, CU DON C. FORD BUILDING OFFICIAL DCF/ph cc: Pat 1loffman J r CITY OF ,Qtilale' """ p ficial Office of Buildi'NSPE�ION REQUEST FOR �--�� ---- f / Permit No. Date P.M. Time iv Receed / Locality U/ J b Addre s Contra ln[ MECHANICAL 1 Owner's RIC PLUMBING ❑ Air Cond.& ❑ Name ELECT r, Rough ❑ Beating ❑ CONCRETE Rough irin� J TOP Out ❑ Fire place BFooting ng ING G TemP Pole 2 Sewer Pre Fab Framing ❑ Slab C, Final Be Roofing LSP intel ECTION ❑ Insulation P.M. READY FOR INThurs. Friday ed. Tues. A.M. P.M. Mon. � ectio Final Insp ancy gitv_inspection M e Q C Certificate of Occup � c insp °f i� Date DATE; PRE-:SERVICE DIVISION JACKSONVILLE ELECTRIC AUTHORITY :x'33 WEST DUVAL STREET JACKSONVILLE, FLORIDA 32202 THE FOLLOWING FINAL INSPECTIONS) HAVE BEEN MADE AND ARE SATISFACTORY : ��' G 9► _� g �c ------- ----------------- --------------------------------------------------- ---------------------------------------------- ------------------------------------------ Enclosed are the blue copies of the permits. SINCERELY, BUILDING INSPECTION DIVISION cc: F I:LE CITY OF ATLANTIC BEACH, FLORIDA C� Approwd by APPLICATION FOR ELECTRICAL PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE: &i4 194z IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. ELECTRICAL FIRM: MAS01R EL C RIICIAN/SIGN,rATURE JOURNEYMAN NAME ADDRESS: ( / aY RFD BOX BLDG.SIZE BETWEEN: RES.K APT.( I comm.( 1 PUBLIC ( 1 INDUS. i ) NEW( ! OLD ) REW. ( 1 ADDITION ( ) TRAILER ( ) TEMP. ( ) SIGNS ( 1 SO. FT. SERVICE: NEW( ) INCREASE ( 1 REPAIR ( 1 FEE CONDUCTOR SIZE AMPS COPPER i ) ALUM. SWITCH OR BREAKER AMPS PH W VOLT RACEWAY EXIST.SERV.SIZE DG AMPS PN W VOLT RACEWAY FEEDERS NO. SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.90 AMPS. 91.100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPS. OVER APPLIANCES BELL TRANSF. AIR H.P. RATING H.P. RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CELL HEAT: KW-HEAT 0.1 OVER MOTORS N.P. VOLTAGE PHS NO. 1 H.P. VOLTAGE PNS MISCELLANEOUS YP.S�38M 8. DEPA 'MENT OF 9011 1, , CITY CSF ATLANTIC BEACK PItI Iif�'C�A'tO» �- LOCATION INFORMATION W r wµw.�+re Perixii t Rul,mb 5 3t Addre : . Fe r,mi t' T12 9� BEACH AVENUE �p§: ELEC'TRIcAt : ATLANTIC BEACH, FLORIDA 32233 Ciss, t .work,: , #EAI UESCRIPTIOFI „ Type, WOOD FRAME' Lot :' Bl caOk Sec--- P ; P a Case: E!OoL F ILX TOzmship; RNC: 0 i ncs rCo d 0 Subdivision 0 , 0 . I P OV. Cost:., , Total tees. 'S2S .60. .Amour 0. �p bat 5/ / . Work Del UBREPAIR TO 150AMP SERVICE APPLICATION FEET Na PERMIT w Addy a ' . AVENUE WATT IMPACT FEE �, " $o I OH, � >C DA O OORLORIA SEE Ag U114 w' RADON OAS-H',R.,S. $Q. JC? ..., O. . ORMATIOH �---,-�-- RAT3C�N OAB� � ��� $0 06 - _ " a Hafiz V L RIS" CO WA'xElk TAP $0 .A4 rAddr4 _1004_, " .:. .. _ ...' .. wrv: �IC JACK LLE. FLS t HYDRAULIC SNARE $0,00 I,� 4C►t}91 ''YP CAPITAL IMPROVE:. SEC.it IMPACT PEE �' 'Yh 'amrym;H+a" "ad.Sn T M . �t�bTFS: 7 NOTICE—ALL CONCAETE FORMS AND FOOTINGS MUST BE 1NSPECTED BEFORE PO URINC3 PERMIT VOID SIX MONTHS AFTER DATE OF 18SUE BU1Lt3_}INC3 MATERIAL,RUBBISH,AND DEBRIS FR OM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE tEARf:D UP ANC?HAULED AWAY;BY EITHER CONTRACTOR OR OWNER' . T4 COMP Y LTH THE MECHANIC' L­ __N LAW CAN RESULT IN T PR0FsERTY OWN E I pAYiNG TWiC`E FOREU�LpiN 1i�iMt?VEMENTS." 777 f i EO ACCORDING TO-APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT1t1 �1 F7 TO REVOQ f 1/IOLATIONOFiPPLlC�4Bk1",PROVISION -00-li1lV: ATLANTIC BEACH.BUILDING DEPARTMENT " By; , CITY OF ATLANTIC BEACH, FLORIDA APPLICATION POR E«CTRICAL P94MIT TO TME CHIEF ELECTRIGAL INSPECTOR: DATE;' I ✓ 1' or"TANT NOTICE- IN CONSIDERATION,OF PERMIT GIVEN FOR DOING THE,, K AS,QESCRIQ D.. N THE FOLL.Iiiil , . E HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE.ATTACHE4 P 5 AND SPEpIFIC/►TIO S: WHICH ARE A PART HEREOF. AND IN'ACCORDANCE WITH THE ELECTRICAL REGULATION% CODES AND CITY OF ATLANTIC BEACH ORDINANCES. M• NAME ADDRESS: RM. molc Afi•t A/�',t 1 C+OAAM.t 1 MLIC! 1 INDUS.1 1 NSW 1 1 OLA REW:1 1 AOpIT10N! 1 TRAILER 1 1 TEMP•i 1 SIGNS 1 1. SEAVICL6i NEW! 1 INCREASE i 1 REPAIR _FEE-• . C'MDUCTOR SIZE MAPS COPPER I I ALUM. -ER PH W V" RACEWAY RV.66Z t/J t_./ AMPSVOLT 2 1 J A SEEDERS NO. SIZE NO:. - SIZE NO. SIZE - LIGHTING OUTLETS CONCEALED OPEN TOTAL _.. . . , tetoo.. RECEPTACLES CONCEALED OPEN TA O•i0 AMM. 31.1AMPA. awlTCN�a NCIWOEiiCENT ' FLUORE_ SCENT i M.V.• IIXiD oo MPS. ����. Ar►uwNGa�s BELL:TRANSF. AIR M.P.RATING H.P..RATING COMP.MOTOR OTHER MOTORS AMPS LEIL HEAT: KW 4EAT" APPLI(XI:' C}a� IT)IJ UAra I 'r' CITY or, MI.���ITEVII AE.&C PROPL-= CUIER i Address:���._.�.��_L� APPLICANT, IF iER THAN OWNER r7arne Day x z- Address; T JCB j Address or Location; ,....�I 2,,-2 i 13 cC: G� Z w-� Legal Description: is well to be ]LLsed for drinking purposes?_� Any person, individual, corporation or other entity receiving a permit: as provided in Section 22-40 of the Atlantic Beach Code, and who plans to tM7e crater from the permitted well for drinking purposes, must first: obtain a bacteriological test report from,the State of Florida Health Departnrnt, fttmiishing a certified copy thereof to the building departmoit: of rhe Atlantic Beach. A certificate of occupancy will not be iss,,.22t report is on file with the building department. Department Notes: Y I agree to cCxrmly with regmIations stated herein, s� : re aged ooda d 03�pdojYi� 6u,ti°off S, AN �eu,3 O 3L3��N ope 3 yal a�PP JI aa,3 ��� a`aW/aa � o a5� dore ,�� eN f ,', F F s�Sg14844 r � 4 DEPARTMENT OF BUILDING GIT'QFATLANTiG BEACH � H i ..:, PZ;M I.T INFORMATION LOCATION 114PO MAT I ON Ferret Number; 1994A ldres 91 BEACH AVENUE Permit Type: WELL ATLANTIC REACH, FLORIDA 3223 Clays pf Werk: NEW LEOAL DESCRIPTION ion t.r. Type: WOOD FRhXE Lot* 'Block,r Section: : Proposed Use:, UTILITY Township,. RNG: 0 I? ellixigs : 4 Code: . t} Subdivision: . ` �:gstimated Value: $0 .00 Imprflv. Cost: $�3 t8 Tota ArrmcouIM 'I, . r . ... ,.•� ', TION APPLICATION FEES G N PERMIT $10.00 `A r ss• I3 VE Ent ,WA -IMPACT fFEE H{ 'LDRItt 5 s ,SRW P ��` �� now Pil ay 47, � •� rR RR � RADON OAS-''H.R, S. SD.BO C", „ R IPOPXAT I, RADON GAS 5% $0.00 Name: „ w WATER TALC DD t Atic �, a: P.Q. 5S SEWER TAE ? .D{t'` ATLAN � EAC ! HYDRAULIC SHARE D,.,00 _'Type: 7 CA�"ITA� � I�lE�ROV�:. 0� i . a d i Nb P NOTICE-ALL FO�tMS A►ND FOOTINGS MUST BE INSPECTED BEFORE POURING = e ,r. PBRMIT VOID SIX MONTHS AFTER DA T€OF ISSUE BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE p CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER a "FAILURE TO COMPLY WITH THE MECHANICS' LIEN LA CAN RESULT IN E THE PROPERTY OWNER PAYING TWICE FOR BUILDING IPAPR.CIYEMENTS.IQ MIMI =w jaQ= " , TIIE 12i N 681, 3.ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT APTBf1$UBJECT TO-RiSI DATION FOR k UIt 1. TION,f�F-APPLICABLE PROYTSIONS OF LAW. TEI!KM 410.01 4 1=PT ICER: ONI07 A'FICIIDCNG DEPARTMENT 4 � ' CrfY' OF A°ITAIV IC BEAM PROP= OWNER ,y� r�c'iTT1E': /_20 -•�- /" '� Day Phone t- r Address: Zip, ^ ✓��Z APPLIGgU, IF GrHM IIMN OWNER i Name: �cJ� fjjj.� ,arc Day ',FhoS�r �F Address: fie x Zip, JOB Address or Location: L,�_�al Description: Is well to be used for drinking purposes?_ Any person, individual, corporation or other entity receiving a pernut as provided in Section 22-40 of the Atlantic Beach Code, and who plans to use uater from the pernnxitted well for drinking purposes, raist first obtain a bacteriological test report from the State of Florida Health Departnimt, furnishing a certified copy thereof to the building department of the City of Atlantic Beach. A certificate of occupancy will not be issued until said report is on file with the building department. Department Notes: T agree to ccarmly with regulations stated herein: ,.gz_ e I Date 473? DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH PERMIT INFORMATION -- - LOGATION , INFORMATION --------- 4737 - 4737 Addreas 1291 BEACH ,AVENUE Pormit ,TYpe a RE- F ATLANTIC. BEACH, FLORIDA `32233 Class of Works NEW LEGALDESCRIPTION Constr. TYpet WOOD FRAME Lot% Blocks Section Proposed Uses SIN049 FAMILY Townships RNG f0 Dwellings I 1 Codes C Subdivision Estimated Value: $0.00 I*parov. Costs; *0.00 Tot m s g` $22.50 Aistou' *22.:50 �a ATIO i APPLICATION FEES .. ,... _ PERMIT $22. 50 t Addres AVENUE MA IMPAC FEES BQ.04,F` GS � P 4 R222H, .. : �, a Wa a ., � RADON GAS-H. R. S. $0. 00, FORMAT N RADON GRAS 5% $0. 00 Name t DUVA QF`INf C01 WATER TAP... so. 00 Add ews s 275' JO N$ 16LUPF ROAD SEWER TAP, LACI .y JACK LLE, F"L 32216 HYDRAULIC SHARE �W 0. 00 Type. O RE-INSPECT' PEE. #O: Ct} OTHER � '" Dye NOTES: 1 NOTICE ALL CONCRETE FORMS AND FOOTINGS MUST BE.INSPECTED BEFORE POURING ' PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MIDST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN THE PROPERTY OWNER,PAYING TWICE FOR BUILDING IMPROVEMENTS." aIDATION VIE: t2/17191 ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJE EVOCATIO I VIOLATION OF APPLICABLE PROVISIONS OF LAW. DM , ATLANTIC BEACtI ItetILDING DEPARTMENT CITY OF ATLANTIC BEACH PERMIT APPLICATION ROOFING Owner(s).- Address;_ 12;l Cis 'A� Phone:—, Zp2 2 Lot # Block or Unit # Subdivision Contractor: y1c, Phone: , State License No. CCC 0S,_�> Describe work to be done: eQ - P '�) ::& � r Materials to be used: Signature OWNER: * Date: t ti 1 Signature CONTRACTOR: -�I i ESC/Sr%NG CN/MA! Y X 1'-a" 1 cL�a,v Corr_ 5XJ57. ocOuND4 OF EX/ST. SLAf31 J _ . L �r1 /�A / L YM . /,0„ Z:D,e _ �-O,f. CAL< _ �i - �-1 *5 Cl/cc, _t? SECTION 1 a //OTC,=� A./,4LL G EA. C X, 477ACAI _A,/ Z-,435 _ - ANC/a0?5 ,:A, END CrYP,� N x - gOL 75 0 /NSE?75,2IEMo✓E A? WoZK t9+ c9 EXi�iNG NOTE- CENTS? -Cy/M'v /ti! C/a/MNEY w/�1'/� QNO SET _ PElZ.a5/VD/CULA? To FACC aF G1-�LM��Y- �.a �o c�CIST/vG K/A LK A/0 74C y GXG �oST' y :� �?% CoXG /COST, EMF3E0 G-O" rM/N. ) W7*0 EXi5r EL /A 7/ Z=o" GENERAL NOTESs 1. ALL WORK SHALL CONFORM TO THE STANDARD BUILDING CODE, LATEST = EDITION. 111 2. EYISTING CONDITIONS: THE CONTRACTOR SHALL CHECK, VERIFY OR F� FURNISH ALL DIMENSIONS AND ELEVATIONS WHICH AFFECT THE NEW WORK AND SHALL BE RESPONSIBLE FOR THE FIT OF THE WORK. 0 W 3. ESTABLISH REFERENCE POINTS ON THE CHIMNEY AND HOUSE BACK TO A� i to Q A PERMANENT BENCHMARK PRIOR TO BEGINNING WORK. THESE POINTS SHALL BE MONITORED DAILY TO DETERMINE IF MOVEMENT HAS W Q OCCURRED. IF MOVEMENT IS EVIDENT, ALL WORK SHALL CEASE AFTER r SECURING THE SITE AND THE ARCHITECT SHALL BE NOTIFIED. Q v LuC DETERMINATION OF THE CAUSE OF THE IIOVEHENT SHALL BE MADE AND = C u1 A COURSE OF ACTION SELECTED. �} Y in w 4. STABILIZE THE CHIMNEY BY BRACING IT TO SOLID GROUND (I.E.- BELOW THE VERY LOOSE SURFACE MATERIAL) , AS INDICATED. • r Z W � 5. IN ORDER TO UNDERPIN THE EYISTING CHIMNEY FOUNDATION, AND > Q SCC TRANSFER THE WEIGHT OF THE CHIMNEY TO MORE STABLE SOIL, THE ' (� lJc FOLLOWING PROCEDURE IS RECOMMENDED: J A. REMOVE THE STRIP OF SOIL NOTED 1 FROM BENEATH THE CENTER OF THE EYISTING SLAB, TO APPROXIMATELY 2'-0" FROM V EXTERIOR EDGE OF SLAB. THE DEPTH SHALL BE A MINIMUM OF W ll 20", OR AS REQUIRED TO EXTEND THROUGH THE VERY LOOSE MATERIAL ENCOUNTERED IN THE SOIL BORING. B. THE EXCAVATED AREA WOULD THEN HAVE THE BOTTOM OF THE EXISTING CHIMNEY SLAB CAREFULLY CLEANED OF ANY REMAINING (V W SAND BY USE OF COMPRESSED AIR OF A 11INIMAL AMOUNT OF \ �rf WATER. O v C. THE BOTTOM OF THE EXCAVATION SHALL BE CAREFULLY FLOODED WITH WATER IN ORDER TO CONSOLIDATE THE SOIL. EXTREME t , CARE SHALL BE EXERCISED TO PREVENT UNDERMINING ANY O V ADJACENT FOUNDATIONS. D. REZNPORCING WOULD THEN BE PLACED IN THE EXCAVATION AS INDICATED. THE #5 REINFORCING MUST BE DRIVEN INTO EACH BANK OF THE EXCAVATION. CARE SHALL BE EXERCISED TO Q INSURE PROPER LAP SPLICE LENGTHS INTO ADJACENT POURS. t^ PROVIDE CONCRETE SUPPORT BLOCKS AS REQUIRED TO MAINTAIN a PROPER CLEARANCES. ----- --- E. CLEAN ALL REINFORCING AND DAMPEN EXCAVATION. F. FILL EXCAVATION WITH 3000 PSI CONCRETE AND VIBRATE THOROUGHLY. V 6. THE CONCRETE SHOULD BE ALLOWED TO CURE FOR AT LEAST 24 HOURS. THEN THE PROCEDURE A THROUGH F MAY BE REPEATED FOR STRIPS 2 V1r AND 3 . ALL REINFORCING SHALL HAVE A 14INIIIUH OF 3" CLEAR CQ COVER FROM THE EDGES OF THE EXCAVATION. THIS WILL RESULT IN A FOUNDATION APPROXIMATELY 2'-0" X 8'-0" X 20" DEEP. V - � QA 6/Z.5 CRA WA/ OCT 201J" 9 cNCcKEr� RCG Building and Zoning zlzw = NQ• 5 - 11 CITY OF ATLANTIC BEACH j DEPARTMENT OF BUILDING 800 Seminole Road - Atlantic Beach, FI 32233 - Tel. (904) 247-5826 ROOFING PERMIT I PERMIT INFORMATION LOCATION INFORMATION Permit Number: 18253 Address: 1291 BEACH AVENUE j Permit Type: RE-ROOF { ATLANTIC BEACH, FL 32233 j Class of Work: NEW Township: Range: Book: { Proposed Use: SINGLE FAMILY j Lot(s): Block: Section: { Square Feet: Subdivision: ATLANTIC BEACH Est. Value: 6,500.00 { Parcel Number: { Improv. Cost: 6,500.00 OWNER INFORMATION Date Issued: 5/20/1999 Name: HIONEDES, CHRIS Total Fees: gEW 45.00 Address: 1601 BEACH AVENUE { Amount Paid: M 45.00 { ATLANTIC BEACH, FL 32233 Date Paid: 5/20/1999 Phone: (000)000-0000 Work Desc: REROOF CONTRACTORS APPLICATION FEES MONAHAN ROOFING RE-ROOF 45.00 24c 1 { { { I j { i { I I j Ins eettons.Re. uire.d i i j NOTICE - INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND j MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR 9R OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" i ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION I FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. i PAIL C $45.88 14 { � ITY OF ATLANTIC BEA _ Date: 5128/9 �Re# 8858748 CASH Of AL-121,16C agcn. 881888832218@ CITY OF ATLANTIC EEACH, RC(DFiNC- PERMIT APPLICA T ICN JCE LCCATICN: I ZEA' Cil, -� CWNER CF PRCFEF T Y: J \4' C)(\t 8 Q ! CCN T RACTCR: M-r., V,C, CCNTrt,ACTCR'S,'CCRESS: 2 C1 I S AT=- L;CENSE NLNIEEF R C __E= -CNE. '2 Li Z I 1 CESC,FIEE WCRK 7C SE FERFCRMEC: !< £rocs F C'c e ch rc, o;.,s a_ VAL'ur.t .CN CF CCN...i rcUC I;CN fix.. MA7E It LS 7C S"E !SE-7:_-'S SIG NA 7U R E CF CWNER., S,GNA.i URE CF CCN T RAC T CF: ` S'v/CFN TC ANC SUES-CRISEC SEFCRE TIME 7HS � QAY CF\/y NCTARY FUELIC Liaciiirr Insurance Sucplied ........ . P..kj ft Wer-.<ers Ccmpensaticn Insurance Supplied `r _ ' daft0�"" �MIbNSSION M CCK, August 27.2[,. Ccntractcr License Infcrmadcn Supplied sOADEDTNRUTFOYFAINW&i� ; Cccupatcnal License Inicrmatien Supplied Book 9297 Pg 1344 5 MIN. RETURN PHONE �AILI� IrINA►NCl/A%.DRINTING0'_a PAW Bk: 9297 Pg: 1344 Doc# 99125614 Filed & Recorded C 110tice of Commencement 10:28:53 A.M. t HENRY W. COOK. (PREPARE IN DUPLICATE) CLERK CIRCUIT COURT DUVAL COUNTY, FL REC. $ 6.00 To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with section 1113.13 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. 1291 Beach Avenue, Atlantic Beach, FL 32233 Descriptionof property --------------------------------------------------------------------------- _ __ _ Legal:__ Lots _11._12_of_Block_51_____________________ ------------------------------------------------------------------------------------------------------------- General description of improvements __-Roof-Replacement --------------------------- Owner --------------------Chris Hionides 2275 Atlantic Blvd. ,_Neptune_Beach, FL 32266 Address -------------------------------------------- -- ------------------------------• Owner's interest in site of the improvement _-__Fee simple Fee Simple Title holder (if other than owner) _______.-_____________________________________________________. Name ---------------------------------------------------• •------------ ------------------------------------ Address ------- -pC-re ---h'-_--1-------.-------.-.----------•---------------------------------------- Contractor -------Monahan_ Roofing_Contractors_ ----------------------------------------------- Address ---------20101 Kings Circle_#Bz_Neptune Beach, FL 32266 Surety (if any) ----------------------------------------------------------------------------------••--------- Address -----------------------------------------------------------------Amount of bond $--------------- Name and address of any person making a loan for the construction of the improvements. Name ---------------------------------------------------- -------------------------------- ----------------- Address -----------------------------------------------..-.------------------------------ Name of person within the State of Florida, other than himself, designated by .owner upon whom notices or other documents may be served: Petra-Management-, -Inc. Name --------------- -------------- - -------------------------------------------------------------------- P. 0. Box 330448, Atlantic Beach, FL 32233 Address ------------------------------------------------------------------------------------------------- In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06 (2] [b], Florida Statutes. (Fill in at Owner's option). Name ---------------------------------------------------------------------------------------------------- Ir CITY OF ATLANTIC BEACH, FLORIDA , T&nd 7b APPLICATION FOR ELECTRICAL PERMIT Y TO THE CHIEF ELECTRICAL INSPECTOR: DATE: 19 d IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. r ELECTRICAL IRM: MWERELICTFrICIAN SIGUMBE NAME ADDRESS: 1412 71 RFD ` BOX BLDG.SIZE BETWEEN: REL( 1 APT. ( I COMM.i 1 PUBLIC( 1 INDUS.i I NEW( 1 OLD REW.i 1 ADDITION( ) TRAILER( ;I TEMP.'( i SIGNS ( I SO.FT. SERVICE: . NEW l 1 NCAEASE( ! REPAIR{ E t oNQ=OR SIZE AMPS Dd, COPPER ALUM.. SWITCH OR BREAKER AMPS PH W VOLT RACEWAY EXIST.SERV.LtZE 'a204 AMPS PH 3 W OLT .A FB4DERS NSI. --:,SIZE; NO. SIZE NO.`, SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0-30 AMPffi. 31.100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.200 AMPS. OvwR APPUANCES BELL TRANSF. AIR H.P.;RAT1Nf3 H.P.RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS, lcEILHEAT: KW-HEAT ©VER MOTORS H.P. VOLTAGE PHS NO. 1H.P. VOLTAGE PHS n' . a F a. TRANSFORMERS: UNDER 60Q V. OVER 600 Y. T �► 1 1G21 1G27 �' , $iXTEE"st�tTH Us 325 31s33 305 � a y. Z• �• T�b'� Tr�a G IL _ so AV- 1/6 00 N y�P►° H T% �f�p° F h ►r2 140 4 z all Zt 1 iS N to at N k 5'0 277 1 14f 19 1 o in 1 Z/oDgp �OV� to T T O Y CAfro$ y Zpy e7 ��O Y1 FIFTETNTH ST 2r vol' d I z�ePv '00" tr 174 X00 12c. -14PAP oo ZT to U d a +Jo W ri. .r FOURTEENTH ST` O� T% �iU a m 2toP T T ti T t/o n1 144 t3 114 n N T Tv 1 M ryy o 2r a I 2t , 7/l0 T Too k y'~ �� ,'tp� O �� _ 133 2 rear M a" \ O .v T q.N T � � ZC � %10 TIJO 4T n ,00 \1e '0. '� THIRTEENTH Sr, 40 � �•,` r + M � .t C C Off• N ,� O52 M U Z N �Z �o - tV 4T T 12778 N 40C) VIX 1151D 00 Ila PA? rY T fog ? r1 N t ate.,,:� �° �► 2 �= 1 0 3!g tlo- ' IJo tl T!(9 4 j+ P 'r� I `'—► v+° 2S 1 0 7 Tt °rte ' i c _ TwEI.VTH ..T Rk2�•2• 1 �" T _ W 4'2 2 2-1/e-Z/o 1 f.T In2c� n Y 4422 C. 14,50 tGSGo t6GZ IGGtb x1674 50 SO so 4427 1to33 tG4.9 (D55 4444 tG t� 4440 IG44 1448, #452 ILSG 1460 tGC4 6481 -` Sp _ so so __L SEW SATS /.7:q/4'F 4447 4454 tG55;f ftts59 4445 IGG'T tG't JtryOL� 44EACH RD. 147 .SEMfNOI.� .C?t A CH RD. f,7 y N 1429-1 C0GLUMA PL. rile CZa _ en a A 14 OCEAN BLVD. a "t -i *, --(BEACH AVE.) �9 0 t2 y 145 14411 45147 I 3 16181 1443 1 n 1i?e7 474 4p onto t? ch X 73 to t"' tI� rn u� I> . m =l CITY OF L - J Office of Building Official. REQUEST FOR INSPECTI VV' �a . p Date � Permit No, Time A.M. Received /_PR� A Job Address ocality Owner's r Name � o`i'iir L —� Contractor 4 BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing ❑ Footing ❑ Roug Ring ❑ Rough ❑ Air Cond. & ❑ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Insulation ❑ Lintel ❑ Final Sewer ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION A.M. Mon. Tues. Wed. Thurs. Friday A.M. Inspection Made z' ©(n P.M. Inspector Final Inspection ❑ Certificate of Occupancy ❑ Date +r David T Cook, Electrical Contractor 1200 Big Tree Road Neptune Beach, Florida 32266 904-249-0967 TO: City of Atlantic Beach RE: Property of Chris Hionides 1299 Beach Ave Atlantic Beach Attention: Don C. Ford Mr. Ford, This to acknowledge our phone conversation on Tues. 4-11-2000, conserning the above mentioned property. That on this date I obtained a repair permit and the necessary repairs will be completed as quickly as my schedule permits but no later than Thur 4-20- 2000. So that a final inspection can take place no later than Friday 4-21-2000. Thanks for your help. Sincerely, � w David T Cook 4-12-2000 rxir 1 ;? 2000 City of Atlantic Beach Building and Zoning MW M P-1 MW 1'_6A FEW 800 S1,1MINO) 1w Roan 4,2 4 0 0, r-. ir-a 717 inn Z7--- ae.%A r_vzv A-^ 61— • up— not nain pamng as Soon as MS OftodAir,q -e!v!ce nas n0!Deen reV31-- A—.1 4 A ')nt%f% mm in wir%lmllinn Un tIr P, CITY OF ATLANTIC BEACH, FLORIDA App►cwd by APPLICATION FOR ELECTRICAL PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE:../ L-/ 19t� IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. ELECTRICAL FIRM: MASTER ELECTRICIAN SIGNATURE JOURNEYMAN NAME C�/ .; ADDRESS: BLDG.SIZE BETWEEN: RES.( 1 APT. ( ) comm. ( ) PUBLIC ( ) INDUS. ( 1 NEW( ) OLD ( 1 REW. ( ) ADDITION ( ) TRAILER ( 1 TEMP.( ) SIGNS ( ) SQ. FT. SERVICE: NEW( ) INCREASE ( 1 REPAIR ( ) FEE CONDUCTOR SIZE AMPS COPPER ALUM. SWITCH OR BREAKER 11 AMPS PH W O1-T &-RACEWAY EXIST.SERV.SIZE AMPS PH W VOLT RACEWAY FEEDERS NO. SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.90 AMPS. 91.100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPS. I OVER APPLIANCES - BELL TRANSF. AIR H.P. RATING H.P. RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT O-1 OVER MOTORS H.P. VOLTAGE PHS N0. 1 H.P. VOLTAGE PHS MISCELLANEOUS 'rn A K100^M&ArMV I ......�.. ........ - -- - - A ntj C A'rj jkj'rjn P DEPARTMENT OF BUILDING 0 Simminolo Road-A ,='c Qe;ach, E71 L 3223") -T 1: 2 47-5826 Fax' 2417-58 ,77 U — . 0 lei Z.41 za- ELECTRICAL PERMIT PERMIT INFORMATION Lid C kt t 6NP W- F-6 F t M-kfrd N- PermitNumber- 198-69 Permit Type- ELECTRICAL ATLANTIC BEACH, FL 32233 Class of Work: REPAIR I Township: Range: WOK: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet.- Subdivision: AT LANTIC BEACH Est.Value: Parcel Number: Improv. Cost: OWNER INFORMATION —H —E D—ES—, CHRIS MR Date Issued: 4111/2000 1-0 NIS Total Fees: `tEI.00 1601 BEACH AVENUE I a zu Address: Amount Paid: 25.00 i ATLANTIC BEACH, FL 32233 A-�j- I Date Pair: 14/11 11,d W-UU Phone: (000)000-0000 6 ' 1 'AMPS�i R 3W 246V 8 El LAW ALUM--REPAIR METER CAN Work Desc: 0 CON APPLICATION FEES DAVID T. COOK PERMIT insoections Required II NOT iCE= - INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS, PRIOR TO tNSPECTION BUILDING MAT ERI AL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER -FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORMNG TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. 0 $25.0314 Reeeiot: 004846, Date: 4/11/00 01 103 CHECKS, -7 AT`j�A T1 EjjArw Q DEPT.B _ °Y: fw#AS 1 i �_ Rh "1! la ?f1/10 SF.,�911VU1_.P. R-QAFI - - rk �.._ --� _w��i -_-�__��!'.. _.. _�.__. --- _. .� - ..rte..+•% -i-� J TRI EPPO E(904) 2,47-5800 } � ± r � ��• -,sl1 \ f-'HA I�Y1,14,1 /4/-lXlf� SUNC-OM 852-5800 ADM3ERADM6ax 010.0 . l r ii, ryat_i a t-i unides Zc3i.5 Atlantic Soullei/al-d 114eOlt uneeA-Ch_ ('•1_ 344^^ of f v4141�J 1 f� , 1 zf`?! %3 n a lir icorrections r too ta/,i! in.. r!d j nn -4 29n iacte.-- notice e o. a,. anee vaa,id,,1,4 a4a.I r1`Gso u as IGa70 a_: •..i vxs:, a:-: ::_z:�. _:!� �:: z-zz :s:-: ,-:s Ml.vv v: ! .P�CA%.LY as U= av i�c� k-aII -11Ct U Mu .,_,..x....... 0000..... ...l.. attached to the;oirall, the claMDs at tine load side of the fiery Te are r-sted throula^yn and holes .n ...-z .n - — - t j-f a,c IIi file I,Ieic! a.ai!'i, !rr l,a�tla_,r r��s�� i!R!�' c�l4ll�p is very-^,3nnal•r!!r mnA nes3i•i4+ toni.ac.+.. nr. repair'ng aC semi as I•assiblp ..� .. w lrvvvlv.v. As UI' tJ;jv'fi I-JA7P inP CPrvl!'.P %1aC nni noon ronoirori nn A-M 4A �7AAA ♦1.._ I a_ - _a �nnr. n . .. - _ •Y::a 4�::: f�� _-4):Lj _a�3��..j.x II=w':ii Yi.vv F3 tF- : ^..':.rF Fi II ••3 F•FC —•fi T:Y� S �„_ �:i.�T i w! ��.�� a�vMv.l I :�ar„lM�r Y�111 UL Ylrll.aj1117 4aGU ULC to the arorementioned code violations. Specifically; vola are in violation of Section 110-13(-\ ail,al IG44111t �•u ! n-U ! !! �u ) (iiv, a„GI�auiia Uel711!_ pina40paii mgm -nn ♦ 9A1PCv 1P if _- - - - _ __-- SiI1cerely, it = Don C. Ford, C.R.01. 6zl..el.'#enr �lfere�! .0 l ell cc: City manager DARCEL NUMBER Duval County Tax Roll DIST OWNER 1999 Real Estate PAGE 498 170292 0000 USD3 GST TRUST JUST 445,950 **000498-01*** SEC 16 TWN 2S RNG 29E C/O C D JR & JOHN TOWERS TR CLASS PUSE = 0100 .59 ACRES 1301 RIVERPLACE BV SUITE 1500 LAND 398,250 3K 7985 PG 2394 DATE 11/1994 X100 JACKSONVILLE, FL 32207-9020 IMPRVMT 47,700 8,8131.78 NOV 4Y DEFER 7.4711 GGUSD 3,331.74 6-1 16-2S-29E ATLANTIC BEACH LOTS 4,5,6 BLK 51 8,893.46 DEC 3% ASSESS 445,950 5.9400 SCHLST 2,648.94 8,985.15 JAN 2Y TAXABLE 445,950 2.7510 SCHLLC 1,226-81 9,076.83 FEB 1% .0440 FLNVGD 19.62 9,168.52 MAR OY. 3.1721 ATL. 9 1,414-60 .4820 STJRVM 214.95 .6993 VOTED 311.86 TOTAL 9,168.52 - - - [70293-0000- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -JUST 563,089- - - - - - - - - -- - - - - **000498-02 - - - - - - - - ** ;EC 16 TWN 2S RNG 29E ".4 Im RT D CLASS 'USE = 0100 .26 ACRES BEACH AV LAND 265,500 !K 8893 PG 622 DATE 0311998 < NTIC BEACH, FL 32233 IMPRVMT 297,589 11,113.76 NOV 4% DEFER 7.4711 GGUSD 4,206-89 ;-I 16-2S-29E ATLANTIC BEACH LOTS 7, 11,229.53 DEC 3% ASSESS 563,G89 5.9400 SCHLST 3,344.75 11,345.29 JAN 2% TAXABLE �65,089 2.7510 SCHLLC 1,549-06 11,461.06 FEB 1% .0440 FI-NVGD 24.78 11,576.83 MAR OY 3.1721 ATL. B 11786-17 .4820 STJRVM 271.41 .6993 VOTED 393.77 TOTAL 11,576-83 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - 7U294 0000 JUST 834,591 **000498-03*x EC 16 TWN 2S RNG 29E CLASS USE = 0100 .26 ACRES 1277 BEACH AV LAND 265,500 K 9177 PG 1741 DATE 12/1998 4908t000 ATLANTIC BECH, FL 32233 IMPRVMT 569,091 15,978.98 NOV 4% DEFER 7.4711 GGUSD 6,048.54 -1 ATLANTIC BEACH LOTS 9,10 BLK 51 16,145.43 DEC 5% ASSESS 854,591 5.9400 SCHLST 4,808.97 16,311 .87 JAN 2% 601GENERAL 25,000 2.7510 SCHLLC 2,227.18 16,478.32 FEB 1% TAXABLE 809,591 .0440 FLNVGD 35,62 16,640.77 MAR OY 3.1721 ATL. B 2,566.10 .48211 STJRVM 390.22 .6993 VOTED 566,14 TOTAL 16,644.77 - 702950000 USD3 HIONIDES- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - JUST 632,100 **G00493-04- - - - - - - - - - - *- - - - - - - - - - - - - EC 16 TWN 2S RNG 29E CHRIS & NADIA CLASS USE = 0100 .26 ACRES C/O SURFACE TECHNOLOGIES CORP LAND 265,500 K 4528 PG 1043 DAT` 12/1977 6700,000 2275 ATLANTIC BV IMPRVMT 366,600 NEPTUNE BEACH, FL 32266 DEFER 7.4711 GGUSD 4,722.48 -1 ATLANTIC BEACH LOTS 11,12 BLK 51 12,475.82 NOV 4% ASSESS 632,100 5.9400 SCHLST 3,754,67 12,605.78 DEC 3% TAXABLE 632,100 2.7510 SCHLLC 1,738.91 12,735.74 JAN 2% 0440 FLNVGD 27-81 12,865.69 FEB I.X 3.1721 ATL. B 2,005.08 12,995-65 MAR 0% .4820 STJRVM 304-67 .6993 VOTED 442-05 11?e 99 TOTAL 12,995.65 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - k Q�LANT�c Z3 filoR10Q- • OF ADDITIONS or • - - • D• NOT REMOVE JOB ADDRESS DATE THIS JOB HAS NOT BEEN COMPLETED The following additions or corrections shall be made before the job will be accepted Z - G 0 AJM F_c 7-,04,r ('P X//UC S rD If �N n 1-0" s't.04 OCV57f'o 7H�?ac�it 3 /62c.L S !N /1 JE r"S A Gtf- iL,5 f C Q N Tip c T OWZ- 4/1-5/tv /1-5/ty 71 -ii(0 61WIS '�y2vr r� i $15.00 REINSPECT t x ,a It is unlawful for any Carpenter, Contractor, Builder or other persons,to cover or cause to be covered, any part of the work with flooring, lath, earth or other material, until the proper inspector has had ample time to approve the installation. After additions or corrections have been made, call 247-5826, Building Depart- PLUMBING ment for an inspection. Field Inspectors ELE re in the office from 8:00 a.m. to 5:00 P n. Monday through Friday. B`� Q "l CITY OF 1 daak--c /3ecicli- � Office of Building Official REQUEST FOR INSPECTION //7 Date / _ Permit No. Time A.M. Received P.M, /-117 District No. a�wAddressLocality Owne Name BUILDING CONC ELECTRICAL PLUMBING MECHANICAL Framing ❑ Footing ❑ nng ❑ Rough ❑ Air.Cond.& ❑ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Lintel ❑ Fire Place ❑ Pre Fab READY FOR INSP A.M. Mon. Tues. Wed. Thurs. Friday P.M. Inspection Made \\--' inspector / inallnspect Certificate of Occupancy Date DATE: ------------- FRE-SERVICE DIVISION JACKSONVILLE ELECTRIC AUTHORI'T'Y 233 WEST DUVAL STREET JACKSONVILLE, FLORIDA 32202 THE FOLLOWING FINAL INSPECTION(C) HAVE; BEEN MAC)T: AND ARF SATISFACTORY : ------------------------ ---------------------------- T i SIm"LY. , BUILDING INSPECTION DIVISION cc:FILE _ BUILDING AND ZONING INSPECTION DIVISION CITY OF ATLANTIC BEACH AYLJINTIC S•<ACiI.FLORIDA 3AR33 APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER IMPORTANT—Applicant to complete all items in sections 1, II, 111, and IV. TBUILDING Street Address: v f. I."sae}(sup Streets! Between t� 5 And G� .CSub.d(vhion If. IDENTIFICATION —To be completed by all applicants, (n consideration of permit given for doing the work as described in the above statement we hereby agree to perform sold work in eccorciance with the attacipd plans and Specifications which ere a parr hereol and in accordance ..it6 the City of Jacksonville ordinances and standards of good.practfce listed therein. Name of Maceanical Contractors Cenlraaior !Print) .V - t Mubr i CA C- Home of i Property Owns ' Slynefurt of Owner I ...� Signature of I at Authorized Agent I '"`+ ,Architect or enginser j Ill. GENERAL INFOR Type of heating fuai: I 15 OTHER CONSTRUCTION BEING OONE ON EfecYnc I THIS SUII.OING OR SITET_ ��s ❑ Gas—- U ❑ Nature( C Central Utility IF YES, GIVE NUMBER Oil �OFr�CONSTRUCTION ❑ I +07. li PERMIT ❑ Othsr—Specify IV. MBCMAMICAL SQUIPMON'T TO lE INSTAUM NATURE OF WORK (Provide compieta list of componenh on back of this form( Residential or a Commercial $� Most ❑ Space ❑ Rocessod )�Canthi ❑ FAW i C New Building AIr Con4ttbaiow ❑ Room J, Canfrel I Existing Building ❑ Dect Syrtem: Material ThIck,,,. i Repiacement of existing system Maximum capacity r f.r4 a New Installatlon(No system previouaiy Installed) ❑ blairigerefioa ❑ Extension Or add-on to existing system ❑ Cooling twee Capacity9-p^ G Other—Specify ❑ Fire ttannklen: Number of hwdr ❑ Efovetw ❑ Manlift ❑ Esealssor (numbed THIS SPACE POR OFFICE US&ONLY ❑.6aso>✓ina Rum(+. (number) f (iVoti.ed) ❑ Texas (number) I Esmarks ❑ LPC contsinara lnumbarl ❑ Unflnd pressure"Not ❑ MiMn Permit Approved by Dol.. ❑ Crow—spedfy Permit Fig. LIST ALL EQUIPMENT 5 Ant CONDITIONING AND REFRIGERATION EQUIPMENT IttmlberUaltat Desoription Yodel Number' Xanulaatauer (Klpsse)y A,`gessoy r(�v MATING •FURNACES, BOILERS, FIREPLACES ' Ca A a an Vft Nsbar Ubee a1ta oriptlaa Yodel Numb" ' ][usutaadtrar ( TU) W 1"L – O Ak TANKS RM 1"ay No bw Capeclb Type LtgW4 Name of Serial Ap�g Bad Dlm�adoee Contain74 ed mDlacturw ^No. CITY OF ATLANTIC BEACH, FLORIDA 3 Arprowdby APPLICATION FOR ELECTRICAL PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE: 191 RIPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLAP,, C BEACH ORDINANCES. tt1CC�dNOMPSON ELECTRIC rp„ 141, P. 0. pp-')X 3 Dir ' ATLANT!C BEACH FL 32`2-­ '� - ELECTR//IC,AA�ILf FIRM: MASTER EL CTRICI SIGNATURE NAME= i ._._._—ADDRESS:-. �-'� ���1- RFD BOX BLDG.SIZE BETWEEN: RES. _ APT.( 1 comm.( 1 PUBLIC I I INDUS.1 I NEW( ! OLD( ) REW.( ) AOOITION ) TRAILER ( 1 TEMP.( ) SIGNS ( 1 SO. FT. SERVICE: NEW( 1 INCREASE ( 1 REPAIRp4 FEE CONDUCTOR SIZE z AMPS / 7S-COPPER I ALUM.ticl CH BREAKER /2-S-A-MPS PH W -27V0LT RACEWAY EXIST.SERV.SIZE S AMPS PH ?W � VOLT RACEWAY FEEDERS NO. SIZE NO. SIZE I NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0=50 AMPS. 51./00 AMPS. SWITCH Es VACANDESCENT FLUORESCENT&M.V. rump 0.100 AMPS. OYER "FL.IANCES BELL TRANSF. AIR H.P.RATING H.P.RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 0.1 OVER MOTORS H.P. VOLTAGE PHS NO. 1 N.P. VOLTAGE PHS MISCELLANEOUSCx anya('494g4-4LP TRANSFORMERS: UNDER 600 V. OVER 600 V. NO. I KVA NO. rVA