Loading...
Permit 1502 Beach Avenue CITY OF ATLANTIC BEACH } 800 SEMINOLE ROAD J ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 �Jxi1=3s Application Number . . . . . 09-00001021 Date 7/20/09 Property Address . . . . . . 1502 BEACH AVE Application type description RESIDENTIAL OTHER Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 10000 ---------------------------------------------------------------------------- Application desc replace slider ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BREMER, R. L. OWNER 1502 BEACH AVENUE ATLANTIC BEACH FL 32233 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 80 . 00 Plan Check Fee 40 . 00 Issue Date . . . . Valuation . . . . 10000 Expiration Date . . 1/16/10 ---------------------------------------------------------------------------- Special Notes and Comments *2007 FLORIDA BUILDING CODE W/ 105- 106 SUPPLEMENTS . 2007 FLORIDA BUILDING CODE - RESIDENTIAL. 2005 NATIONAL ELECTRICAL CODE. *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 80 . 00 80 . 00 . 00 . 00 Plan Check Total 40 . 00 40 . 00 . 00 . 00 Grand Total 120 . 00 120 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. s r� CITY OF ATLANTIC BEACH 09� I I + I I 800 SEMINOLE ROAD,ATLANTIC BEACH,FL 32233 I_ ;l OFFICE:(904)247-5826•FAX NO.:(904)247-5845 " BUILDING-DEPT@COAB.US BUILDING PERMIT APPLICATION DUVAL COUNTY 1.JOB ADDRESS: 2.VALUATION OF WORK: 3.SO.FT.UNDER ROOF 15001Z 8600(0� V6 1/4 t6c 4.LEGAL DESCRIPTION: 5.C 15% OF WORK 6.USE OF STRUCTURE ❑NEW BUILDING ❑DEMOLITION RESIDENTIAL LOT_BLOCK_SUB DIVISION ❑ADDITION O CONVERTING USE ❑COMMERCIAL 7.DESCRIPTION OF WORK / f J , / �j ❑ALTERATION ❑ACCESSORY BLDG. 8.FIRE SPRINKLER: re(aal2 Yef�(4Ce- Sllc `� (:�o©YS rJ' I� REPAIR ❑OTHER PA ❑YES WA 5 ❑MOVE ❑OTHER ❑NO PROPERTY OWNER: CONTRACTOR: ARCHITECT I ENGINEER: 9.NAME: f�C��S V �r✓'YL 15.COMPANY NAME: 23.COMPANY NAME: 16.NAME: 24.LICENSEE NAME 10.ADDRESS: 17.STATE OF FLORIDA LICENSE NO.: 25.STATE OF FLORIDA LICENSE NO 1 5©a leACW 4tlt A-T f V f r(C t36�,.l,y J 18.ADDRESS: 26.ADDRESS: 11.OFFICE PHONE: 12.FAX NO.: C 19.OFFICE PHONE: 20.FAX NO.: 27.OFFICE PHONE: 28.FAX NO.: n .�(p � 5�4rN PHONE: 21.CE L PHONE: 11 29.CELL PHONE: I. 14.EMAIL ADDRESS'. 22.EMAIL ADDRESS:_-T1T-`- 30.EMAIL ADDRESS: rVSs Cp bgemer,n lei- FEE SIMPLE TITLE HOLDER: BONDING COMPANY: MORTGAGE LENDER: OF OTHER THAN OWNER) 31.NAME: 33.NAME: 35.NAME: 32.ADDRESS: 34.ADDRESS: 36.ADDRESS: Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six (6) months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs,Wells,Pools,Furnaces,Boilers,Heaters,Tanks, Air Conditioners,etc. OWNER'S AFFIDAVIT-I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning.1 will not occupy or use the referenced building or any part therof,until all inspections are{naled and prior to obtaining a certificate of occupancy or completion issued by the building official,as required by law. WARNING TO OWNER: * YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECT" . IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER ORMATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWN rAGENT CONTRACTOR If t,Power y or Agency Letter Required) (Qualifier Only) Sig i Date: Otd) f/ " Signed: Date: Befo a this of ,2009 n the my of Before me this day of 2009 in the county of Du ,Sta Flo as pe ppeared Duval,State of Florida,has personally appeared herin by hims If herself and affirms that all statemen declarations are herin by himself/herself and affirms ,a� "I true and accurate. true and accurate. Notary Public at Large,State of ,County o aL Notary Public at Large,State ofI my E f!fj nY ❑Personally Known /" ❑Personally Known UUF y Produced Ident' tion- ❑Produced Identification- R ��+'v'A•.;a"f abs.'zi -:',; {t. Notary Signature. Notary Signa REVIEft RLEY L.GRAHAM CITYOF RCO�DT.E.rCOMPLjA1C},; Lild4Net Public-State of FloridaAT�uca.t�i1C BEAC. _My Commisissi Expires Feb 14,2010R SE EE ERMITS FOR ADDI TIONA,f HBLDG01PennkApplicatio �2/1�P>drtm Nati# l otary A REMENTSAND CONDITIONSBonded Ey National Notary Assn. L ED BY. DATE: �4� CITY OF ATLANTIC BEACH / . ®WNER / BUILDER AFFIDAVIT I. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING"REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7),FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY.TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE—OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF$25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE, THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE, WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR.. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL_ LICENSING ORDINANCES. II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE, THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. III. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO. 455-228(1). AN"OCCUPATIONAL LICENSE' IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY "CERTIFICATE OF COMPETENCY" OR THE FLORIDA "CONTRACTORS CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. TELEPHONE THE BUILDING DEPARTMENT(247-5826)IF IN DOUBT. V.ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. l 5 a -1 cr�G� ��� l 'rel ADD S PHONE NUMBER _! , r Ca Q S- I rl�vl z v- y `� PRINT NAM SIGNAT.R DATE /Bore me this y of 201— in the county of tate of Florida,has personalty ap ared herin by himself/herself and affirms that all statements and declarations are true and accurate. Notary Public at Large,State of County of _ 0 Personally Known 0 Produced Ide n- SHIRLEY L.GRAHAM •tPpY PVO Notary Public State of Florida f 1 Notary SignaturSulon Expires Feb 14,2010 Commission#DD 518533 F:BLDG/Owner-Bw it;REVISED:14/16/2009 , Bonded By National Notary Assn. NOV-25-22000 08:30 FROM:CLERK OF COURTS 904 270 1512 1U:ydel( tb9' 17- Ll i NOTICE OF COMMEM MMT (PREPARE IN DUPLICATE) Permit No. Tax Foho No. State of County of i To whom a may concern: The undersigm4 hereby infomis You that trrapravements vrW be made t ft eefaln neat property,and In accordance WM Sectlon 713 of the Herres Sfadntas,the following Intonowort Is stsmd In Oft N=C2 OF GOtiAIMENCLM>Ni: Wal desallptlan of Mopedy be)ng kMmved: Address of ptopeety behtg improved' Ganeral descrvkm of improvemerds: Z 142 G L- e!=o77 �^ ©w Y Owner G 5' S rL a'. �- u"'' 1 /'l�l���• Address •y" .� ' u c .�� Owners'merest in site of the hgxvvemant Fee Simple TRieholder(if other than owner) Name Address Contreaor `�gffi Q- 1k bpye- ' Address Phone No. Fax No. 5uretp tit arty) Address — Amount of bond S Phone No. Fax ft. i Name and address of any person making a loan tot the constnfetion of the improvements. Name Address Phone No. Fax No. Name of person within the Stabs of Fiorfda,other then hkttself,designated by owner upon whom no§M or other docm*rft may be served: Name Address Phone No. Fax No. r In a Wdion to hftelf,owner designates the Wowing poses to receive a Copy of the Lianor's N00ce as provided In Section 713.06(2)(b),Florida Statutes.(Flt in at Owrter's opllon). Name Address Phone No. fax No. ExpkWon date of Notice of Commenoement(tft e*rafion delta is r horn C1e date Ol'recordhtQ Wt1656 a different date is specifiiecl): THIII SPACE FOR RECOROWS USE ONLY R ,,^ DATE / (/� siglllfx` r a ore has APP-94 .-. - .. ...._.. fl,aby ' ane steams mat as slriafffatds ahfr deelareNoas Coe#20091 W61.OR SK 149.39 Page go?. We true and sawrote SUSAN K.SULLIVAN Number Pages:I W commissrONN Doiollsi Rp=ded 0711412009 at 0*()o PM, ExP►Rr•-5:Au uos,2011 JIM FULLER CLERK CIRCUIT COURT DUVALwan r--� "'0P"'�'T""r Ff 1oj"^'T'a+� •ta COUNTY Nataryk' S _ � nNa_ y�� +..,,.,.,..�^.• :,, P.ECORDING$10.00 NlyntofnmisalsnexpBes, il- Pataeneay Kffawn PraraoeQlaenwOosNon Page 1 of t John Ford L4 3 From: John Ford oford46872@bellsouth.net] Sent: Thursday, July 09, 2009 3:17 PM To: 'neeluers@netscape.com' Subject: FPAS#'s for Bremer residence Attachments: FL12442_RO_II_1659%20%201nstallation%201nstructions%a20with%2OEvaluation% 20Report.pdf, FL12603_RO_11_Pella%20Fixed%2OFrame%2OWindow%2OSealed% 20Drawing%201656.pdf Mark, Here are the Florida Product Approval Numbers for the Bremer Residence. Impervia Window= FL 12603.5 Designer Series Sliding Door= FL 12442.2 and FL 12442.5 Attached is the engineering needed for permitting. Thank you, John Ford Pella Windows & Doors St.John County Sales Representative 904-534-1641 jford@pellajax.com 7/16/2009 C06ccs cD GENERAL NOTES: - Iuy srs� O. ALL FASTEN SHNL BE N ACCORDANCE WITH THESE DRAWINGS. SPECIFIED ANCHOR EMBED To BASE WATERIAL shat BE BMW WALL FINISH FOR MAX. FRAME WIDTH, SEE "ALLOWABLE DESIGN OR S.W. PRESSURE" TABLE ON THIS SHEET 2. OPENINGS, BUCKING&BUCIONG FASTENERS MUST BE PROPERLY DESIGNED&INSTALLED TO TRANSFER WIND LOADS TO THE STRICTURE ` MESE NON-IMPACT RATED DOOR SYSTEM INSTALLATIONS ARE IN ACCORDANCE WITH AND MEET THE REOUREMENTS OF THE FLORIDA BUILDING CODE 6" MAX.. 10" MAX, Q,G 6" MAX. 4. ALL ANCHORS SMANG DOOR FRAME TO PRESSURE TREATED BUCKS OR WOOD FRAMING SHALL BE CAPABLE OF RESISTING CORROSION CAUSED BY THE 5. MATERIALS �w CHEMICALS NOT LIMITED To WOOD. SCREWS,THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SNAU MEET THE A FRAME SCREWS � REQUNLEMNIS OF FLORIDA BUILDING COOT CHAPTER 20. 4 WHERE SHOWN 6 TO THE BEST OF OUR KNOWLEDGE.THE DOORS SHOWN HEREIN ARE CERTIFIED&QUALITY ASSURED BY A FLORIDA STATE APPROVED AT HEAD. SEE CERTFICAT10N/OA ENTITY&SHALL BE LABELED IN ACCORDANCE WITH THE FBC AND THE 98-72 FLORIDA BUILDING COMWSSON SPECIFICATIONS. DOOR ASSEMBLY IS NOT PART OF THIS DRAWING AND SHALL BE N ACCORDANCE WITH THE MANUFACTURER'S QUALITY ASSURANCE SPECIFICATIONS&TESTING "FRAME ANCHOR REPORTS. I REQUIREMENTS 7. COMFICATTON OF THESE DOOR NSTALLATONS SHALL BE CONSIDERED VOID IF ANY OF THE FOLLOWING APPLY: T)THEY,INE INSTALLED WITHOUT A TABLE" ON THIS WaING PERMIT FROM THE APPLICABLE LOCAL BUILDING DEPARTMENT, 2)BEY THARE INSTALLED BY ANYONE OTHER THAN A LICENSED CONTRACTOR w ® INACTIVE EXPERIENCED WITH DOOR INSTALLATIONS. 3)IF CHANGES HAVE OCCLM TO THE PRODUCT'S CERTIFICATION ENTITY'S CERTIFICATE THAT CAUSE THESE GO I, B g SHEET FOR INSTALLATIONS TO BE INCORRECT OR INCONSISTENT WITH WHAT HAS BEEN TESTED. 3 N qFSTRICEq REQUIREMENTS a, THE LEAST DESIGN PRESSURE SPECIFIED EIMER IN THIS DP"NG OR IN THE PRODUCTS CERTIFICATION SHALL CONTROL FOR THE INSTALLED DOOR.9.THESE ORAWNOS CERTIFY THE DOOR INSTALLATION ONLY WATER PROOFING OF THE INSTALLED ODORS IS NOT PMT OF TMS NSTA.LATION rn E OFPOSITEffCERTIFICATION.. THAT RESPONSIBAJTY SHALL BE THAT OF THE MANUFACTURER&/OR NSTALLERz -- I No ALTERNATE ANCHOR/ W M EVALUATION _ STRIKE SCREWS INTO I NOTE: o SUBSTRATE (1 PER SILL SCREWS ALL ALTERNATE ANCHORS IN THEIR SPECIFIEDz x= STRIKE). SEE FRAME WHERE SHOWN 0 w SUBSTRATES HAVE BEEN ANALYZED IN ACCORDANCE w II°o ANCHOR SEE "FRAME w�0 WITH THEIR APPLICABLE STANDARD(S) AND ARE FOUND DAN 0 TO BE EQUIVALENT TO OR STRONGER THAN THE REQUIREMENTS I ANCHOR 0 �o ANCHOR(S) USED IN TESTING WITH THIS PRODUCT w TABLE" ON THIS REQUIREMENTS FIN FASTENER za 4 a SHEET FOR SCREW I TABLE" ON THIS WITHIN 4" OF O N M z REQUIREMENTS. SHEET FORc fO o CORNERS & 8" 0 �g REQUIREMENTS a r w MAX. O C. SEE S to ROLLER2w a o "FRAME ANCHOR �z�+ ° FRAME ANCHOR REQUIREMENTS TABLE RETNNER I REQUIREMENTS n OPENING TYPE MINIMUM MINIMUM -;j TABLE" ON THIS .1 FRAME TO OPENING FASTENER TYPE SHEET FOR (SUBSTRATE) EMBED EDGE DIST. REQUIREMENTS 0: FRAME/SILL SCREWS 6" MAX —, 1- -I I-6"MAX MIN 2X4 WOOD FRAME OR BUCK 3" TESTED (MIN. GR. 3 & G=0 55) N0 10 SMS OR WOOD SCREW 1 1/4" 3/4" RETAINER SCREW INTO SUBSTRATE (1 MIN, 18 GA. 33 KSI METAL STUD NO. 10 GR. 5 SELF TAP DRILL SCREW FULL 1/2" PER RETAINER). SEE "FRAME ANCHOR EXTERIOR ELEVATION: c REQUIREMENTS TABLE" ON THIS 2-PANEL SLIDING DOOR DOOR a� q ,? MIN. 1/8" THIO A36 STEEL N0. 10 OR. 5 SELF TAP/DRILL SCREW FULL 1/2" SHEET FOR SCREW REQUIREMENTS SCALE: 1/2" = V-O" cn A MIN. 1/8" THIO 6063-T5 ALUM. NO. 10 GR. 5 SELF TAP/DRILL SCREW I FULL 1/2" SDA��31 C-90 CMU/2500 PSI CONCRETE (1) 1/4" CONCRETE SCREW 11 1/4" 2" ALLOWABLE DESIGN PRESSURE z WN STRIKE/RETAINER SCREWS (2-PANEL SLIDING DOOR) J,R I MIN. 2X4 WOOD FRAME OR BUCK (1)DOOR STYLE MAX.FRAME FRAME PRESSURE MAX ALLOWABLE zzIn (MIN. OR. 3 & G=0.55) TESTED NO 8 SMS OR WOOD SCREW 1 1/4" 3/4" g g � MIN. 18 GA. 33 KSI METAL STUD 40. 8 OR. 5 SELF TAP/DRILL SCREW FULL 1/2" WIDTH HEIGHT (+/- PSF) ) (IN) .a n MIN. 1/8' THK A36 STEEL N0. 8 GR. 5 SELF TAP/DRILL SCREW FULL 1/2" (IN. 3 g°-' MIN. 1/8" THK 6063-T5 ALUM. NO. 8 GR. 5 SELF TAP/DRILL SCREW FULL 1/2" CONTEMPORARY 95 1/4 95 1 2 403 C-90 CMU/2500 PSI CONCRETE (1)3/16" CONCRETE SCREW 1 1/4" 2" FRENCH 95 1/4 95 1/2 55 (2)NAILING FIN FASTENERS FRENCH 71 1/4 95 1/2 65FRENCH 95 1/4 81 1/2 65 MIN. 2X4 WFRAME OR BUCK NO 8 SMS SCREW 1 3/8" 1/2" (1) CONTEMPORY & FRENCH ARE THE SAME EXCEPT F o : (MIN. GRR 3 & G=0.55) THE DOOR PANEL STILES & RAILS OF THE FRENCH MIN 2X4 WOOD FRAME OR BUCK ARE TALLER THAN THE CONTEMPORARY. LL bid (MIN. OR 3 & G=0.55) 2' X 11 CA ROOFING NAIL 1 7/8" 1/2" sv CA- MIN. 1/8- THK A .36 STEEL NO8 GR, 5 SELF TAP DRILL SCREW FULL 1/2" NSrALUTION EVALUATION IS BASED ON APPLICABLE ANCHOR STANDARDS AND/OR / INFORMATION&RESULTS FROM APPLICABLE TEST REPORTS. THE FLORIDA BLALIDNG MIN. 1/8" THK 6063-T5 ALUM NO. 8 OR, 5 SELF TAP/DRILL SCREW FULL 1/2" CODE VERSION CONSIDERED WITH THE EVALUATION Was THAT IN FORCE AT THE TIME 3 OF THE EVALUATICN. IN THE EVENT OF CODE VERSION 0"GES/UPDATES OR IN (1)CONCRETE SCREWS SHALT_ BE ELCO ULTRACONS, ITW RAMSET/RED HEAD TAPCONS, THE EVENT THAT NEW OR ADDITIONAL TESTING IS COMPLETED ON THE REFERENCED ORA""N 77 HILTI KWIK-CON 11 OR POWERS RAWL TAPPER (HARDENED STEEL OR SS PRODUCT.PRIOR TO STATING CODE COMPLIANCE WITH THE STATE.THE MANUFACTURER 1659 SHALL COM WIM THE INSTALLATION EVALUATION 04GMEER OF RECORD THAT THE (2)WHEN SCREWS ARE USED WITH THE NAIL FIN, THEY MUST BE A WAFFLE HEAD SCREW NSTALLATMS SPECIFIED HEREIN ARE CURRENT WITH THE THEN CURRENT TESTING sHEEr No OR HAVE A FLAT WASHER AT THE SCREW HEAD CODE AND APPLICABLE STANDARDS. 1 of ¢ . Wnr wu 48 3/4' MAX 144" MAX FRAME WIDTH FRAME MOTH 3" 3" 6" MAX 10" MAX. O.0 6" MAX 6" MAX. 10" MAX O C. 10' MAX. 0 6'MAX. 4 —FRAM-'_ SCREWS 4 FRAME SCREWS � WHERE SHOWN WHERE SHOWN ' AT HEAD SEE AT HEAD. SEE "FRAME ANCHOR "FRAME ANCHOR REQUIREMENTS //, I REQUIREMENTS sw umTABLEON SET"IQ FOR /, ® ^�"��I ® S" SHEETTABLE"1 FOR B B REQUIREMENTS 8 q REQUIREMENTS aProslrE oPPo511E W W FIN FASTENER FIN FASTENER a WITHIN 4" OF WITHIN 4" OF E� CORNERS & 8" u CORNERS & 8" MAX O C SEE MAX. O C. SEE "FRAME ANCHOR "FRAME ANCHOR �m REQUIREMENTS SILL SCREWS REQUIREMENTS F W N N N I WHERE SHOWN �0 R TABLE" ON SHEET ti SEE "FRAME TABLE' ON SHEET �p NL 1 FOR 1 FOR 'n REQUIREMENTS SILL SCREWS WHERE I ANCHOR REQUIREMENTS. e o Z!5 SHOWN. SEE 'FRAME if REQUIREMENTS v �. T j ANCHOR TALE" ON THIS a Ns� REQUIREMENTS TABLE' Ro11ERSHEET FOR o�^o ON SHEET 1 FOR REQUIREMENTS. i a REQUIREMENTS. % c0i 6' MAX. 6" MAX fi" MAX 6' MAX w o EEO EXTERIOR ELEVATION: RETAINER SCREW SNTO SUBSTRATE(1 PER RETAINER) SEE "FRAME a SINGLE OXER PANEL DOOR ANCHOR REQUIREMENTS TABLE' ON SHEET 1 FOR SCREW REQUIREMENTS gy ao SCALE: 1/2" = 1'—O" EXTERIOR ELEVATION: H "x 9—PANEL SLIDING DOOR WITH SIDELIGHT Aja ALLOWABLE DESIGN PRESSURE SCALE: 1/2" = 1'—O" 125 o 1 (CONTEMPORARY & FRENCH STYLE SINGLE FIXED PANEL DOOR) ALLOWABLE DESIGN PRESSURE oz z +/- 80 PSF (CONTEMPORARY & FRENCH STYLE y$t 1 2--PANEL SLIDING DOOR NTH SIDELIGHT) x (1) CONTEMPORY & FRENCH ARE THE 3� SAME EXCEPT THE DOOR PANEL STILES +/- 40 PSF & RAILS OF THE FRENCH ARE TALLER 3 THAN THE CONTEMPORARY. SAME EXCEPT EX ECEPPT THE T & FRENCH ARE THE SAE DOOR PANEL STILES W & RAILS OF THE FRENCH ARE TALLER a THAN THE CONTEMPORARY. gn o wy �O c z 0. aW U4 a �s5s 2 aF 4 /0663- 57 FMCHM RAL NOTES ASIEPERS SHALL BE W ACCORDANCEWITH THESE DRAWINGS. SPECFlED ANCHOR EEIBED TO BASE MATERIAL TOR MAX. FRAME SHORT PRESS RE"ON, FORMme• FRAME SHORT DIMENSION,BEYOND WNL FINISH OR STUCCO, SEE 'ALLOWABLE DESIGN PRESSURE" SEE °ALLOWABLE DESIGN"PRESSURE"INGS,DUCKING 3 BUCKING FASTENERS MUST BE PROPERLY DESIGNED k INSTALLED TO TRANSFER WIND LOADS TABLE ON THIS.SHEET TABLE ON THIS SHEET TRUCTURE.E NON-IMPACT RATED IWNDOW SYSTEM RWNAA71ONS ARE IN ACCORDANCE MRH AND MEET THE REWIREMENM 2MAX. MAX. I 2 6" MAX. LORIDA BUILDING CODE(FBC). O.C. I2 CHM SECURING W14M FRAME TO PRESSURE TREATED BUCKS OR WOW FTTALNNG SFWL BE CAPABLE OF -COMM"CAUSED BY THE PRESSURE TREATING CNEMMIILS IN THE WOOD. a MATERIALS,INCLUDING BUT NOT UNITED TO STEEL SCREWS.THAT COME INTO CONTACT WTTN ODDER DSSIIDIAR 6" MAX. MATERULS SDWL MEET THE REOU IFSO 5 OF FLOROA BUILDING CODE CHN TER 20. // 6. TO THE BEST OF OUR KNOWLEDGE THE W OM SIDWN HEREIN ARE CERTIFIED k OUAUIY AS"EO BY A FLORIDA /// STATE APPROVED(ERRFI =RAA ENBIY Nc SHALL BE LAWLED I7 ACCORMICE WOH THE FBC ALD THE 98-72 FLORIDA WALDIM.COiNSSION SPECITCARONS. WINDOW ASSEMBLY S NOT PART OF THIS DRAWING AND SHALL BE W SgI(AR SIIBlAR SIAAR ACCORDANCE WITH THE MANUFACTURER'S WHIM ASSUPoINGE SPECFICATADW d TESTING tEPoRTS. 7. CERIFOTWN OF T}ESE MHpOW WSTALLATIONS SHALL L BE CONSIDERED VOID F ANY OF THE FOLLOWNG APPLY: I) A A AL2 rAh THEY ARE INSTALLED WITHOUT A MALOW PERMIT FROM THE APPLICABLE LOCAL BUILDING DEPARTLERE 2)IF THEY ARE 2 2 2 2 INSTALLED BY ANYONE OTTER TWN A LICENSED CONTRACTOR E UUMNCED WITH WINDOW WSTALLAIM. 3)IF CHIMM W OCCURED TO THE PROOUC S CERTIFICATION ENTRY'S CERTIFICATE THAT CHASE THESE WSTAUAMONS TO SE INCORRECT OR INCONSISTENT WTN DANT HAS BEEN TESTED. m H RESSIIE SPECIFIED FRIER W THIS DRAWING OR W THE PRODUCTS CERTIFICATION SHALL THE LEAST DESIGN A 3 FRAME SCREWS WHERE CONTROL FOR THE WALLED WINDOW. 0.THESE.ORAWINGS CERTIFY THE 1RNUON 96UIMM ONLY. WATER PROOFING OF THE INSTALLED VANDOWS S NOT p w o w SHOWN. SEE"FRAME PANT OF THIS INSTALLATION CERTIFICATION. THAT RESPONSIBILITY SHALL BE THAT OF THE M WACTURER B/OR N FIN FASTENER WITHIN 3" Oyj ANCHOR REQUIREMENTS INSTALLER. w rn OF CORNERS do 5"-7" w(nTABLE"ON THIS SHEET . H MAX. O.C. SEE "FRAME Awn A= FOR REQUIREMENTS. Z ANCHOR REQUIREMENTS Z Z Zo rn o IISTALIATION EYPLUAMON S BASED ON WKWABLE MOM STANDARDS AND/OR o TABLE"ON THIS SHEET o F rr o a IFORMANON&RESULTS FROM APPLICABLE TEST REPORTS. THE FLORIDA BIA.DNG A',_f' FOR REQUIREMENTS. Z � I CODE VERSION CONSIDERED WITH THE EVALUATION WAS THAT IN FORCE AT THE TIME Q 12 MAX. z 2_5 N OF THE EVALUATION. IN THE EVENT OF CODE VERSION CHANGESAUPOATES OR AN F- p D-• O.C. l:R THE EVENT THAT NEW OR ADDITIONAL TESTING S COMPLETED ON THE REFERENCED ca- PRODUCT PRIOR TO STATWG CODE COMPLIANCE WITH THE STATE.THE MANUFACTURER LO 1tA C7 w SHALL CONFIRM WITH THE INSTALLATION EVALUATION ENGINEER OF RECORD TINT THE Z j p INSTALLATIONS SPECIFIED HERE-IN ARE CURRENT WITH THE THEN CURRENT TESTING. CODE AND APPLICABLE STM40AR M w w w w a �a ALTERNATE ANC ISL�STRATE EVALUATION NOTE• 4 L ALL ALTERNATE ANCHORS IN THEIR SPECIFIED SUBSTRATES HAVE BEEN ANALYZED IN ACCORDANCE o wo WITH THEIR APPLICABLE STANDARDS)AND ARE FOUND o TO BE EQUIVALENT TO OR STRONGER THAN THE o w ANCHOR(S) USED IN TESTING WITH THIS PRODUCT. FRAME ANCHOR REQUIREMENTS TABLE p2 Aar (3)FRAME SCREWS OPPOSITE OPPOSITE Az = is �9, OPENING TYPE 2 j i •• MINIMUM MINIMUM (SUBSTRATE) FRAME TO OPENING FASTENER TAPE EMBED EDGE DIST. 6" MAX wz 1 riJfN. 4 WOOD FRAME OR BUCKLN. GR. 3 do 13=0.55) NO. 10 SMS OR WOOD SCREW 1 1/4" 3/4" TESTED jig MIN, 18 GA. 33 KSI METAL STUD NO. 10 GR, 5 SELF TAP/DRILL SCREW FULL 1/2" �S MIN. 1/8" THK A" STEEL N0. 10 GR. 5 SELF TAP/DRILL SCREW FULL 1/2" EXTERIOR ELEVATION: EXTERIOR ELEVATION• MIN. 1/8" THK 6063-T5 ALUM. NO. 10 GR. 5 SELF TAP/DRILL SCREW FULL 1/2" SINGLE W_1NDOW SINGLE WINDOW and SCALE: 3/4 = 1'-0" SCALE: 3/4" = V-0" C-90 CMU/2500 PSI CONCRETE h) 1/4" CONCRETE SCREW 1 1/4" 2" (NAIL FIN MOUNT CONDITION) (FRAME SCREW MOUNT CONDITION) 2)NAILING FIN FASTENERS ALLOWABLE DESIGN MIN. 2X4 WOOD FRAME OR BUCK N0. 8 X 1 1 2" SMS 1 3 8" i/2" o rMIN. IN. GR. 3 k 0=0.55) / / PRESSURE RECTANGULAR WINDOWS SHOWN. X4 W000 FRAME OR BUCK MAX. MAX. ALLOWABLE SHAPED WINDOWS APPLY �'1 1/2" X ii GA. ROOFING NAIL . 1 3/8" 1/2" TESTED FRAME FRAME PRESSURE IN. GR. 3 h G=0.55) LONG DIM. HORT DIM.(+/- PSF) WITHIN PROVIDING THEY FIT THE R CTANGULARABED. 1/8" THK A36 STEEL NO. 8 GR. 5 SELF TAP/DRILL SCREW FULL 1/2" (INJ (IN.) DIMENSIONS SHOWN do ANCHORS /8" THK 6063-T5 ALUM. NO. 8 GR. 5 SELF TAP/DRILL SCREW FULL 1/2 120 60 50ARE SPACED THE SAME AS NCRETE SCREWS SHALL BE ELCO ULTRACONS, RW RAMSET/REQ HEAD TAPCONS, 108 66 50SHOWN. TI KWIK-CON 11 OR POWERS RAWL TAPPER (HARDENED STEEL OR S.S.). 102 72 50 1656EN SCREWS ARE USED WITH THE NAIL FIN, THEY MUST BE A WAFFLE HEAD SCREW g0 78 50 sHEEr No. OR HAVE A FLAT WASHER AT THE SCREW HEAD. 84 84 50 F Z (3)FRAME SCREWS MUST BE A PAN OR HEX HEAD SCREW. s- 1pr,�;; City of Atlantic Beach APPLICATION NUMBER �s Building Department (To be assigned by the Building De artment.) v 800 Seminole Road J� .j � Atlantic Beach, Florida 32233-5445 U 9 ��Z Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us L Date routed: 9 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: A D2- Afi. QqpzAMent review required Ye No Building Applicant: (,c?�'J�� anning &Zoning Tree Administrator Project: Public Works —� Public Utilities Public Safety Fire Services RevlevuDept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APP6jpATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDIN PLANNING &ZONING Reviewed by: Date: 9-1-09' TREE ADMIN. Second Review: ❑Approved as revised. ❑ enied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: [—]Approved as revised. [—]Denied. Comments: Reviewed by: Date: Revised 05/14/09 f CITY OF ATLANTIC. BEACH 800 SEVIINOLK ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE:LINE 247-5826 Application Number . . . . . 07-00000002 Date 1/24/07 Property Address . . . . . . 1502 BEACH AVE Application type description ELECTRIC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc converting to underground/add receptacles ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BREMER, R. L. BILL THOMPSON ELECTRIC CO, INC 1502 BEACH AVENUE 49 WEST 7TH ST ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 249-5601 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee . . . . 70 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/23/07 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 70 . 00 70 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE VNM ALL CITY OF ATLANnc BEACH ORDINANCES AND THE FLORIDA BUHMING CODES. CITY OF ATLANTIC BEACH r ELECTRICAL PERMIT APPLICATION Date: Property Address: ��5 Z- /,� ����. 4'(I Owner: 4 .ES a Telephone Contractor: Telephone#: O. ,BOX 330150 _ Contractor AddressATLANTIC BEACH, FL 32233 Fax#: Contractor Signature: In consideration of permit given for doing the work as described ' the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Building: Building Type: ❑ Trailer Service: If other construction is ❑ New jit Residence ❑ Temp. ❑ New being done on this building Or site,list the building ,2( Old ❑ Commercial ❑ Signs ❑ Increase Permit number: ❑ Re-wire ❑ Addition Sq.Ft. le Repair Conductor Size: AMPS: COPPER ALS Switch or RACE Breaker AMPS PH W VOLT WAY Existing Service '��,-y� 'Z (�V Z p RACE!/ Size AMPS '` - PH W VOLT WAY Number �� 1 MeteritsI-,-,k/ Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED OPEN Receptacles CONCEALED OPEN Switches Incandescent Fluorescent & M.V. Fixed 0.100 AMPS OVER BELL Appliances TRANSFER. Air H.P.RATING H.P. RATING CEILING KW-HEAT Conditioning COMP.MOTOR OTHER MOTORS AMPS HEAT Motors 0-1 H.P. IVOLTAGE PH NO. OVER 1 H.P. PHS UNDER600V OVER600V Transformers NO. KVA NO. KVA No.Neon_Transf. Ea. Si Miscellaneous �/./rdQ •P� !�f`G C� i1 �� J�CDGlG� e r 800 Seminole Road•Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800. Fax: (904)247-5845• httn:/hvww.ci.atlantic-beach.fl.us Revised 1/04 „ k JOBADDR= /5©Z &a 6h TYPE WORg PROPERTY 0wNERC SSS TELEP�SONE a q-( -' 9 Zz� CONTRACTOR S ONE TGv PERWTNUMBM DATE lZ-OSS'-OCA INSPECTION,. FOOTING SLAB TM BF” I.IIVTEL NAff.1NGVSEWATHRVG FRAWVGICOVER UP INULAITON FINAL BUILDING CERTIFICATE OF OCCUPANCY ELECTRICAL PERMM INSPECTIONS ROUGH FINAL 1 (e MEC ZUMCAL PERAff" INSPECTIONS ROUGH FINAL PLUAMWG PER fin LVSPECTTONS ROU NAMER SLAB TOPOUT WAT FINAL NOTES: Jr� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD } µ � ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 04-00027499 Date 1/13/04 Property Address . . . . . . 1502 BEACH AVE Tenant nbr, name . . . . . . 6 ' WOOD FENCE Application description . . . FENCE PERMIT Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 1000 Owner Contractor ------- -- -- -- ---- --- - --- - - - -- - - - - -- ---- ------ --- BREMER, R. L . EASTERN SHORES CONSTRUCTION 1502 BEACH AVENUE 1015 ATLANTIC BLVD. ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 246-6056 --------- ---- ----- - ------ - -- - --- - --- - - - --- - - - - - -- - - - -- - --- - - - - - - - -- - -- ------ Permit . . . . . . FENCE PERMIT Additional desc . . Permit Fee . . . . 35 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ------------ ---- - -- -------- -- - - - - ---- - -- - - ----- ---------- Permit Fee Total 35 . 00 35 . 00 . 00 . 00 . Plan Check Total . 00 . 00 . 00 . 00 Grand Total 35 . 00 35 . 00 . 00 . 00 BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS"ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. B DING OFFICIAL CITY OF ATLANTIC BEACH CD. Ford BUILDING / ZONING DEPARTMENT L S 800 Seminole Road S. Doerr J Atlantic Beach,Florida 32233 (904)247-5800 r sf (904)247-5845 Fax PLAN REVIEW COMMENTS Permit Application # - Property Address: 1 SSC.% i ✓�- Applicant: Project: n This p rmit application has been: Approved Reviewed and the following items need attention: Please re-submit y r applicat' when these items have been completed. Reviewed By: Date: Q Z' re J � sf1 ? CITY OF ATLANTIC BEACH � r,3 ,, FENCE PERMIT APPLICATION Dater Job Address: / �_O a -f f C-11 fi Ve Owner's Name: �B v S z- 0 re/C-/',? �- ,,- Address: ,-Address: / s- o 'a /: q C_ t? //V/"- Phone: _2 Legal Description: Block Number: &1­ 3 Lot Number: Zoning District: M Q A-, A y Fence Contractor: S_(r �� G� 1 f0 S T- Address: /© / 5� /4 T�--i A-. T/ L- V q L Phone: '5`� S City: 19T A 7 <- 7 a 14 c_ State: F�- Zip: 3,� 2 3J Fax: �G(!? `7 G Type of fence and materials to be used: 1 C-'c-, c'1/z A, do f 4!e S i 92 d 6w ., C e Valuation of fence: ,1606aw Is approval of Homeowner's Association o�r.other private entity required?/VU If yes, please submit with this application. ❑Interior Lot !�(Corner Lot Dumpster or storage tank enclosure �Tre rotection: 0 NO. Applicant certifies that no trees will be removed for the installation of this fence. ❑ YES. Removal of Protected Trees will be required for this fence. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. PLEASE PROVIDE TWO(2)COPIES OF APPLICATION AND THE FOLLOWING REQUIRED INFORMATION: 1. Attach copy of property survey showing location,height and all distances from property lines of the proposed fence. (Fences shall not be placed within any utility or drainage easements without written permission from the Utility and/or Public Works Departments. Fences shall not restrict any private easement.) 2. Provide completed Owner's Authorization Form if applicant is other than property owner. I hereby certify that all in do r0 ided rth this application is correct. Signature of OwnerDate: I l 6 y Signature of Contr zvl Date: Address and contact information of person to receive all correspondence regarding this application (please print): Name: Mailing Address: Phone: Fax: E-Mail: 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 - Fax: (904)247-5845 - http://www.ci.stlantic-beach.fl.us Page 1 Revised 1/14/03 t SURVEY OF LOTS 5 AND 6 , BLOCK 63 , MANDALAY , ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 10 , PAGE 11 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY , FLORIDA . SCALE: 1 " = 20 ' JUNE 15 , 1989 CERTIFIED TO: BREMER BRACE OF FLORIDA, 'INC. ELLIS , CURTIS AND KOOKER , INC. I HEREBY CERTIFY THAT THE LANDS LAND SURVEYORS AND PLANNERS SHOWN HEREON WERE SURVEYED UNDER 1660 EMERSON STREET MY SUPERVISION PURSUANT TO CHAPTER JACKSONVILLE, FLORIDA 32207 472 . 027 FLORIDA STATUTES . PHONE: (904) 396-6334 GENERAL NOTES : \\J _ HARLO G . EVERETT, JR. 1 . ) THIS IS A BOUNDARY SURVEY. P . L . S . NO. 3287 2 . ) NO ABSTRACT OF TITLE FURNISHED. STATE OF FLORIDA 3 . ) NOT ABSTRACTED FOR EASEMENTS . REPRQIMS N TRS SEMVEY PLAT ARE NDT VALI MESS S1"I;E7 AND I hereby certify hat the property shown lies EMBUSSED WfTH THE SURVEYUR'S SEAL. Nwithin. Zone as shown on Flood nsu-,ance Rate Map. For Community No._j� County, Florida t r�NC.t.Tim 02� O�. .._r.tM A.Nl;— 7 .9 s�6 L 7. V jr c rte Q C~ S Nr aMiC Ch TM0 "P 1I "a14N0rm W" oppcebie ^'` too*#, "bowl 1 sad **of, local land tv bat doss not gonatitute N' t a Z ^ yl a f fW q °• tt a� pliance r licable q rementa�{ mit aw prm ntke he My ef Atlantic 10"©h be R pftllf b#10 Bali Of a ° I 0• ' ifs: '' Appwjsd 9 f• s' � S i ,e c.e-'r 3 ,� M h t.F ? .•' adi 24 I DEPARTMENT OF BUILDING .. �� CITY OF ATLANTIC BEACH,FLORIDA PERMIT N V V PERMIT TO BUILD THIS PERMIT MUST BE POSTED ON JOBff�� p 9nom•nnCA f 6620 1N /P6 n Date Sept 23, 19 8$ 10013 N/C (not required) j Valuation$ Fee$ This permit not valid until above fa has been paid to City Treasurer,and is i subject to revocation for violation of applicable provisions of law. f ROSS BREMER This is to certify that 1502 Beach Avenue Ihas permission toted remodel kitchen including one new window (replace existing window with larger) Classification Residential Zone Owned by Ross Bremer Lot Block S/D House No. 1502 BEACH AVENUE According to approved plans which are part of this permit NOTICE—ALL CONCRETE FORMS AND FOOTINGS MUST BE IN- SPECTED BEFORE POURING. PERMIT VOID SIX MONTHS „ AFTER DATE OF ISSUE ----► -----� O Building material, rubbish and debris Zi from this work must not be placed in public space, and must be cleared up and hauled away by either con. traCstnr oWper, Building official. FOR OFFICE PERMIT DATE CONTRACTOR USE ONLY NUMBER PLUMBING ELECTRICAL SEWER WATER JOL046a . Vt"OOL 0"9 CITY OF ATLANTIC BEACH <. APPLICATION FOR BUILDING PERMIT Required Submittals t cf]4 wo complete sets of plans 2. . etailed site plan including setbacks and utilities 3. Re t survey 4. Florida y Efficiency Code Sheets S. Contractor's ense on file REMOVE NO TREE OUTSIDE THE BUILDING LINE THAT IS LARGER THAN SIX INCHES IN DIAMETER UNLESS A TREE REMOVAL PERMIT HAS BEEN ISSUED. Inspection Schedule: 1. Footing 2. Rough Plumbing 3. Slab 4. Framing, rough electric, mechanical, top out plumbing, fireplace 5. Final inspection 6. Certificate of Occupancy inspection Requests for inspections will be accepted fromm 6%00 am until 4sOO pm. All inspections will be made the following. working day between 8:00 am and 4t00 pm. In case of rejection, re-inspection must be called for after corrections are made. There will be a $10. 00 charge for all re-inspections, paid prior. to the request for re-inspection. Pour no concrete or cover up any work until the building card is signed by the inspector. You will be required to uncover any work that has not been inspected. BUILDING CARD MUST BE POSTED OR NO INSPECTION WILL BE MADE Building Department 716 Ocean Boulevard Atlantic Beach-, Florida 32233 249-2395 s page il drig and Zoning CITY OF ATLANTIC BEACH APPLICATION FOR BUILDING PERMIT - R�on�L Owner__Rg��i_L__C3RcOie4_Address tL500L 8C'ad-e Fqv __ziP�'3 Phoned-{6_�L� ---- ---------------- Architect( !'(:LG/1_ V -9Y Address_�'�_ S_ �� T___zip Z2��phonea��_lkSa -------- --- -- --- Contractor �8�_IPQ11`_ � Addrese_� �� .�t �!-(j _zipIL 7 phone�y�__Y�Gj ------------ Contractor's License number.................expiration------------ Lot------- ___________Lot_______Block or Section---------Subdivision----- ----------Zoning---- ____ Street-------------between_------_______and-----------------Bide----------- Type Construction--------------No. Units____y_____No. Fireplaces___________ Purpose of Building__&- 1f Eluation' Sst. Va -a-m- -�-d--v- ----- Utility Method - Water ________ Sewer ----- ------------ Dimensions - Building______________Lot-------------Size Footings___________ Sz. Piers------------Sz. Sills-------------Greatest Span Sills_______________ Sz. Ceiling Joists--------- on Centers __Greatest Span_______ --------- ------- Sz. Floor Joists _Distance on Centers---------Greatest Span_______ Sz. Rafters _________Distance on Centers---------Greatest Span_______ Method of Heating_ Solid or Filled Ground Roof Flood Zone-------If located within a FLOOD HAZARD ZONE complete page 3 In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications, which are a part hereof, and in accordance with the building regulations of Atlantic Beach. The contractor agrees at its expense to provide the necessary access to the properties being developed over dedicated City rights-of-w and to clear, clean, grade, and drain said right-of-way o C y specifications. Signature Own Date SCI - ----------- -- -- ----- Signature C actor ______Date__-aD----------- page 2 FLOODPLAIN DEVELOPMENT INFORMATION Type of Dev opment:-------------------------------------------- Flood Zone:-- ------------------- Required Lowest Floor Elevations_______________ If building is ocated within a flood hazard zone (Zone A), a survey must be m de AFTER THE SLAB HAS BEEN POURED, certifying that the LOWEST LOOR ELEVATION is equal to or above the base flood elevation est blished for that zone. No final inspection ill be made and no certificate of occupancy will be issued unt 1 the survey is on file with the Building Department. COMMENTS: Applicant Acknowledgement: I understand that the issuance of this permit is contingent upon the above information being correct and that the plans an supporting data have been or shall be provided as required. I ree to comply with all applicable provisions of Ordinance No. 25-7-11 and all other laws or ordinances effecting the propos d development. Date..............Applicant's Sig ature.......................... ----------------------------- ---- ------------------ Department Use Required Lowest Floor Elevation ..... ........... As Built Lowest Floor Elevation --- Survey Filed with Building Department---- ---------- ----------------------------------- Building Departmq.nt Representative Page 3 CITY OF ;r4&.#slit Be"4-99lo�aid���� S i/ - Office of Building Official , REQUEST FOR INSPECVNo. — e�RYOH 7: Date _ Perp 3k Time Received P.M. Job Address Locality Owner's / y Name .4�.E /cam Contractor BUILDING CONCRETE EU � PLUMBING MECHANICAL Framing ❑ Footing ❑ Rough Wiring ❑ Rough ❑ Air Cond. & ❑ Re Roofing ❑ Slab ❑ Te ole �❑ Top Out ElHeating Insulation F1 Lintel F-' ma /K�+^ Sewer ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION A. Mon. Tues. Wed. Thurs. nday � M. K.�Inspection Made XM. Inspector Final Inspection El, Certificate of Occupancy ❑ Date CITY OF Office of Building Official - REQUEST FOR INSPECTION - 0 / Date C- Permit No. Time Received M Job Ad{iress Localit Owner's ho�A�� Name / z-!° i Contractor BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing ❑ Footing ❑ Rough Wiring ❑ ❑ Air Cond. & Re Roofing ❑ Slab ❑ Temp Pole ❑ op Out ❑ Heating Insulation ❑ Lintel ❑I Final ❑ ewer Cl Fire Place ❑ READY FOR INSPECTION Pre Fab Mon. es. Wed. Thurs. Fri ay Inspection Made PM Inspector Final Inspection ❑ Certificate of Op�cy �� Date Gff/ � Boors 9e$28��:%04)WO34473 �`�9e' 2370 Page: 2372 Filed & Recorded 02/13/2401 11:39:53 AM JIM FULLER rJ MIN. RETURN CLERK CIRCUIT COURT o2`��e_ NOTICE OF COMMENCEMENT T T DUVk COUNTY 1.00 pHO�t E . RECORDING f 5.40 TO WHOM IT MAY CONCERN: The undersigned hereby infomrs all concerned that improvements will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. Descriptio of p� Lots 5 and 6 Block 63, Mandalay, according to S priat ther o , Page lip euveent peb is 13 record; Duval ee""ty' pleride N ( 1502 Beach Avenue m General Des uiption of improvements Rebuild )� 4 Owner Ross Bremer and Karen Perrin Address: 1502 Beach Ave. Atlantic Beach, FL 32233 Owner's interest in site of improvements: u Fee Simple Title Holder(if other than owner) Nance NA Address Contractor Coastal Craftsmen, Inc. Address F.D. Box 50676 Jacksonville Beach, FL J2250 C1 Surety (if any) NA Address Amount of Bond$ Name of person within the State of Florida designated by owner upon whom notices or other documents may be served: Name NA Address In addition to himself, owner designates the foilowing person to receive a copy of the Leinor's Notice as provided in Section 713.13(1)(F), Florida Statutes. (Fill in at Owner's option). Name NA Address: Owner Sworn to and subscribed before me thisday of Fz�r , �►-�aor •.0 4y4 wdww C Judim * *"M CW-*OM CCOD S No Public 'yro Expires FeWMY 06,2004 CITY OF ATLANTIC BEACH j DEPARTMENT OF BUILDING 44 800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247-5877 I! r €'ELAiIiT INFO 1t1i ►TIOki` - L___ - -- - -1 _ LC1CA7tON 1tNfORMATtON Permit Number; 21106 — Address: 1502 BEACH AVENUE Permit Type: REMODELING I ATLANTIC BEACH, FLORIDA 32233 F Class of Work: REMODEL Township: 0 Range: 0 Book: Proposed Use: Lot(s):5,6 Black: 6 Section:0 Square Feet: } Subdivision: MANDALAY I Est. Value: I Parcel Number: � Improv. Cost: 120,000,00E OIAIN R`1NPt &MALT 1 Date Issued: 12/08/2000 Name• ROSS BREMER Total Fees: 780.00 ( Address: 1502 BEACH AVE. j Amount Paid: 780.00 ATLANTIC BEACH, FLORIDA 32233 ! ( Date Paid: 12/08/2000 �6 Phone: /904)246-6721 Work Desc: REPLACE WINDOWS AND DOORS; REAR 2ND FL{�OR-DECK;R OF; REMODEL BATH '-� NT !�3RF 'S ,, • ► . . i TI .` FE ! COASTAL CRAFTSMEN, INC, PERMIT 780.00 j C I i f I � i I + I :1r7flspec a R quFred . j FRANiNG/COVER-UF FAL BUILDING 4TNSUL ATION ft � � i 1 NOTICE-INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED Uig AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER I iiFAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAVH CAN RESULT IN THE PROPERTY j OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION � I FOR VIOLATION OF APPLICABLE E PROVISIONS OF LAIN. ii I j 4 ATLANTIC BEACHN �Nt� UiLDiN EPT. ��� ' HCEIVED ,0\, 3 0 2090 City of Atlantic 'Beach CITY OF ATLANTIC BEACH Building and Zoning PERMIT APPLICATION REMODEL, ADDITIONS, OR ALTERATIONS ti U fa' �. ,EN f f_=X ►N NS I Owner(s) : `�D `7 � �1� � // � Job Address: 1 �� *✓ �°� ' Phone: ' ' ��•�� Lot rrBlock or Unit #,p �/�Sub- /division: '^ Contractor: W l.. I�f' y�y�IEA M_ State License Address: T/ w ?7b, t;;t)te-71e Phone No: e-pgtY city/ K*044 I AC tfstate L Zip Code � 11 Describe work to be done: {� �� W j kj.pt 1j1/ i�R SND Present use of building: Kl�t? Fb AJ Valuation of Proposed Construction: x-01 0 0 b C,) Proposed use: Is this an addition? N If yes, what are the dimensions of the added space: "rte ft. X ft. will the added area be heated and cooled? New electrical for increase)?- --' New plumbing fixtures? ' New fireplace? '- New Heat/AC? STJ3!1rr2! TBREE (rnMdEurznT) Two (RESIDENTIAL) COWLETE SETS OF PLANS, n4MUVnrG SITE PLAN, SURVEY, ENERGY CODE FM MS, NOT=CF OF AND ONM/CONTRACTOR T, IF OVIOM ZS CONTRACTOR. Signature OWNER: Date: / - 02 Signature CONT TO; • Date:fT_ � AS TO OWNER- Sworn WNER Sworn to a ' ribdef�`,PERI is day of ,� � 2000. htY CU,v..saas ��tL -�� � . EXPIKEJ;p5f tin,rttt4d rx f { t. ntt�" �`'bt '�"° OT Y L C �-S -3- • AS TO CONT Sworn to and subsc itcheii � da of ���lit_-i ,2000. 'v8i �issv# y :a= 3ury 15 2002 " BONDED THRU TROY FAIN I URAN E pF F4 N Y P I CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Address 16Z 2 ,�4ro+C f / 04- COZ�-(Dva�� Date /o; ' F' 00 Heated Square Footage -% @ $ per sq ft = $ Garage/Shed _@ $ per sq ft = $ Carport/Porch t, @ $ per sq ft = $ V Deck @ $ per sq ft = $ Patio O @ $ per sq ft = $ d TOTAL VALUATION: $ O660 Total Valuation 1st Q0,12 C, ?c_ $ (moo Remaining Value $ per thousand or portion thereof TOTAL BUILDING FEE $ 5"2�� + 1/2 Filing Fee $ Zee ( ) Fireplaces @ $15 . 00 $ BUILDING PERMIT FEE $ WATER IMPACT FEE $ SEWER IMPACT FEE $ WATER METER/TAP $ _ CAPITAL IMPROVEMENT $ SEWER TAP $ ( ) RADON (HRS) . 0050 $ SECTION H PAVING ( ) $ HYDRAULIC SHARES $ CROSS CONNECTION $ ( ) SURCHARGE . 0050 $ OTHER $ GRAND TOTAL DUE $ ADDITIONAL PERMITS OR FEES: Mechanical Plumbing Electric/New Electric/Temp ; SwimmingPool Septic Tank Well Sign Finish Floor Elevation Survey Other CALCULATIONS and/or NOTES : I7EG — 1 — 00 FR I Y : OC, VE Af2CFi I T ECT + fG-iwe. •yY*wtT� °hT„�iy tl�r'•C.i, ;y V '•461i' /� I heroj) r aettt m �lctfoil; tars Within 2049 '� th .t tho .lp-roPGrt lot ka16r1!(A C,'ttESS xr7gi11'A1kC�9 3t 3r �t�crw E30SSEp 9311 iN( Commurki ty Tip batedP. ,;✓ -=�•�—VII on d cy j11�1 r: 9 't• E3 ? �aw•r� Or IX�q rNwK'1►..af41 Yrr+C�♦TC •�_� ♦ ro!',r► rr.' TO •.�"i w 9 , �Jl 7{ IT 0&-W �• r' s-? •rr 0. r ap b r{. .rt 054r r-a'w tire Ter s < or r � %K nI rf�$ •� *' whsle �y Q � i �� � ► V 4, 2 Mid % k • WA I F i' R"t+P dX►mar r„r� p1 i 0 'a � rent RL 4f Ja pill ` 1L.Amillam ` + r t4 , J 4f r 94 A 7 ) I � . �X�����4.) I .. ,.��. .rs5'✓.. APn. ".L:. . y, �rw,.�w ., � .rb!'z^Sl:ii 1.,Ku,•t...rs �... _. _- ..--� ✓AC.I' PAGE:1 rAa!44RM ID:247-5845 DEPARTMENT OF BUILDING /) p°7 1 i C,I�OF ATLANTIC BEACH,FLORIDA PERMIT NO. �F O ( 1 KRMIT T4 BUILD THIS PERMIT MUST BE POSTED ON JOB Date /aluation$ 30,000.00 -F,,$129.75 ++� � I 's permit not valid until above fee has been paid to City Treasurer,and is i revocation for violation of applicable provisions of law. This is to certify that VILLE & MEUSE CONSTRU 214 ORANGE STREET, TUNE BEACH, FLORIDA has permission to buildROOMADDITIONS AS PER PLANS SUBMITTED Classification ROOM ADDITIONS Zone RA Owned by MR. ROSS BREMEIt i Lot 5 & 6 Block 63 S/D House No. 1542 BEACH AVENUE According to approved plans which are part of this permit M NOTICE---ALL CONCRETE FORMS AND FOOTINGS MUST BE IN- SPECTED BEFORE POURING. PERMIT VOID SIX 4S T AFTER DATE OF &TT /_--� 4-------► O Building mail,rubl�i�h a>�c; -1 from this w 7 ust not be in public spp�cg,;And ust up and hae �Fl sway eit�► tractor or owne {UUCI I A. WILLIAM MO S/FWM Building Official. r FOR OFFICE PERMIT DATE USE ONLY NUMBER CONTRACTOR PLUMBING 4873 1-5-82 F. W. FAIR PLUMBING COMPANY i ELECTRICAL 3325 12-10-81 FERRIS ELECTRIC COMPANY SEWER WATER I CCMPIY WITH THE", MECHANICS FOR OFFICE USE ONLY \ RESN T. —0 H RT Y Date------------------------------------19 ...... FACH N ULT I11A"2, fil ........................ "s permit#------•-•............... ------------ ............Fee 4 RWARRYs 6TY,6 VEMENTS. ............................. Valuation $........................ FLORIDAuse #-•......................................................... /� APPLICATION ----------------------------------------------------------- APPLICATION FOR BUILDING PERMIT ............................................ ............................................................................ Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure described. This application is made in compliance and conformity with the Building Ordinance of the City of Atlantic Beach, Florida, and all provisions of the Laws of the State of Florida, all ordinances of the City of Atlantic Beach and all rules and regulations of the Building Department of the City of Atlantic Beach, shall be complied with, whether herein specified or not. The Contractor or Owner-Builder who has been issued a Building Permit is automatically responsible to ascertain that all sub- contractors engaged by him are duly licensed in the City of Atlantic Beach,Florida. To prevent delay or embarrasment regard- ing intermediate or final inspections it is suggested that a list of sub-contractors be submitted to this office so that licenses can be verified. Date...... ........ 0 J e' Owner_..... ..... ......... ...................................Address---A Tel` No, Architect.......6--s.1... Addres&_,.1.M -/.../�,, -��........Telephone No..... ------------------------------ _..�---i.A... Contractor Builder.---6-1...:el, ----�c.lo.(!Address_... ..... elephone ? ...... Ar 2 Lot No----- -_------------------------Block No.--•---- ------------....Sub Division--...._...............-- .......Zone................. ............................................................Street.._--- Side Between...........__......................................and......................................................Sts. Valuation :......................:For. what purpose will building be used..........---------__...............Type of construction... ........... Dimensions of -i�? (/ --- Dimensions of J.-__...Size of Footings.-._ ............ ---- ------- Size of Piers_ _>.. -------------Size of Sills.-----__------ ....Greatest Sill Span in ft...........................Type Roof....__........._..__......_......._... How will Building be Heated?---- -------- --_-------......Will Building be on Solid or Filled Ground?-.-----=............................ Ac .1i to Size of Ceiling Joists-------------------------......P..a-....histance' 'on *1 fe)e . ....................... Greatest Span-------------------------------------------- p ........... Size of Floor Joists----------------------------------------------- Distance on Centers-_-..._.... ..............................-, Greatest Span----_-..-._-..-.._....__-_----.--.-.--.__ Size of Rafters--------•------------_--------_-------------------Distance on Centers... ................. ........ Greatest Span........................................... This rectangle is to represent the lot. Locate the building or buildings in the right position. Give distance in feet from all lot-Ilnes and existing buildings. REAR LOT LINE Two copies of plans and specifications shall be submitted with application. Inspections required. 1. When steel is in place and ready to pour footing. v 2. When steel is in place and ready to pour columns and/or lintel. Z 3. When steel is in place and ready to pour beam. 4. When framing is completed. E-4 5. When rough plumbing is completed,and ready to cover up. 2 6. When septic tank drain field or sewer is laid but before it is covered. 7. Electrical inspection by City of Jacksonville. 8. Final inspection. Note: In case of any rejection,re-inspection MUST be called for after corrections are made. FRONT OF LOT In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications, which are a part hereof, and in accordance with the building regulations of the City of AQantic ) /Z Signature of Builder_...... Address....... ..................... ........................... Signature of Owner...... ................ .............. ------_......:......•---•-.-- Address................................................................. i RTMENT OF BUILDING s . -ATLANTIC BEACH,FLORIDA PERMIT NO. 4,,873 rcr3MIT TO BUILD THIS PERMIT MUST BE POSTED ON JOB Date JANUARY 5 1982 %a3luation$ PLUMBING PERMIT Fee$5.00 V This permit not valid until above fee has been paid to City Treasurer,and is suNmt to revocation for violation of applicable provisions of law. This is to certify that F. W. FAIR PLUMBING C041PANY P. 0. Box 51149, JACKSONVILLE BEACH, FLORIDA has permission to build INSTALL NEW PLUMBING AS PER PLANS SUBMITTED Classification REST.1b$NTIAL zone RA Owned by • ROSS BAR Block63. _—S� C o� twis permit _cosarrE FO NS I � ICE—AL,u GS MUST BE FO��N 1� AND 0 ' A FORS F ,,. ID SII I� T 3I.' { t f { f i 4 3 `l st 000 386 n n4 DEPARTMENT OF BUILDING CITY OF ATLANTICBEACH fi INFORMATIONW LOCATI3 ' RlZT IilCRtA!IQN HUE Addy ss 2386 Permit urbrrs ATLANTIC BEACH, FLORIDA 32233 .1 TypesELECTRICALPo - LEGAL DESCRIPTION -_- CWorks ADDITION Tt wr�nssectiat % .tts 81e�c% *1 N/� hip%am tr. T Rfti�a O I'r*pc, d Ue�tr$ t2tfC3LE It+`01I1.Y rrrtt3rfivcic�r►a A f �r13 tt �� O Codes t3 tod aluwt ' *010,00 1Nt E t1tJ• CCS 4a.00 't % 4r 00 M►2O.00 AcrL{1n� ... Zk7190 aA IFH 3W 240V „ y nom.« APPLICATION FEES T�Vit +�,+ +wk ^w `a� e �"` +� AVENUE I AT#�:R SRF ACT FEE �►p..Cl�l Aa3dri er 4s I RPAC " FEE 4O H R`L•ORlbl � E 'NN„ i� , r Pt + # rad Y ' !' f.�'A y.,ry,�,wy.�1i�Et�J dv" � ' iro �w *R RADON 1147b$—H a R r S- 41, > (30 OftlfA ' N RADON GAS gyp. -- _ V!A'IrEi!L TAP 00. 00 Hain► s `° ILL-, I!fIr' I� 'fsLLC? *C CO r NG SEWER TAS' 1.QO ' . . , , .. A�cla�r �s P#I ` � Y13R4ULIC SHARE _._„ > A `LA, EACN,, FL 32233 �� -,, 2 RE–INSPECT FEE ,�„O. LI0gsfw0� �� Tl ENGIN, EERING ItoNOTES: pr� t NOTICE—ALL CONCRETE FORMS AND FOOTINGS,MUST BE INSPECTED BEFORE MURING t PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BUILDING MATERIAL,,RQ8BISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND M CLEARED UPAND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. i "FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT-v,,,10:. THE PROPeRTY 4WI I9R PAYING TWICE FOR BUILDING IMPROVEMENTS.,wwaulm Witt,04/171%, . ISSUED ACCORDING TO APPROVED'PLANS WHICH ARE PART OF THIS PERMIT AND SUB REYOCAT 7R V16LATION QF APPLICABLE PROVISIONS OF LAW. A%ANTIC WBUILDING D. A ITNIE;IVT Ao Ic ; 0002386 �. DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH PERT [` INFORMATION LOCATION INFORHATT011 Pet rii i l 13�er�rt� s x TL'.€s I.'_~. 0 BEACH AVENUE Pc,xmit Type. ELECTRICAL ATLANTIC BEACH, FLORIDA 322`3' Class-3 of Wr:. k. ADDITION 1.1=,GA' L DESCRIPTION a`oA-jsLx . Type-. H/AC Lot,l Block >eGt Lr,.r;: f x't"pus3ed Ut4ei SINGLE FAMILY TownshipI z RNG: Dwl l i.rxcj 0 Codes O SuladIvi ;pion x A Improv. Cast : $0. 00 To L ail l Fps: $20. 00 I Amount Pald-. X. o"90 XIST 150 . j S APH 3W 240V OWNER INFORMATION APPLICATION FEES w Hamel ROS BREMER PERMIT S20. 00 P,dd*e�ss: - 1502 BEACH AVENUEWATER IMPACT FEE ATLANTICBE 'CH, FLORIDA 0.w.�a 0 , :wI�WE*�� IMPACT FEE E ���. 00 PhCxxx x { } . ta01 WATER METER 00 RADON GAS-_I'f. R. S. CONTRACTOR niroRMATr:EoN _ RADON GAS $0. C3{a Name-. BILL. TEL£}l°II'SON ELECTRIC CO, INC WATER TAP "«0. 00 Add:t`taSErs PO BOX 50038 SEWER TAP $0.00 ATLANTIC BEACH, FL 3=_D3 HYDRAULIC :HARE $0. 00 License, ER000013676 Type-. RE--INSPECT FEE ACL. Ota ENGINEERING $0.00 OTHER , $0. 00 i NOTES: * \4 :i NOTICE —ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS." ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUB" ' t, TO REVOCATION4013 VIOLATION OF APPLICABLE PROVISIONS OFLAW. ATLANTIC BEACH BUILDINGD AITMENT By: CITY OF ATLANTIC BEACH, FLORIDA �C25� Approv"by APPLICATION FOR ELECTRICAL PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE: a 19 IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. 31LL ELEICTRiO CO., INC. P. 0. COY 503 3 r% JACKSONVILLE BEACH FL .32240-0398 ELECTRICAL FIRM: MASTER ELECTRICIAiSIGNiME JOURNEYMAN r NAME ADDRESS: RFD-BOX- BLDG. FD BOXBLDG.SIZE BETWEEN: RES.(V APT. ( ) COMM.( 1 PUBLIC ( 1 INDUS.( 1 NEW( 1 OLD( 1 REW. ADDITION (V TRAILER ( 1 TEMP.f i SIGNS ( ) SO. FT. SERVICE: NEW( 1 INCREASE ( 1 REPAIR ( 1 FEE CONDUCTOR SIZE AMPS COPPER 1 ALUM. 1 SWITCH OR BREAKER AMPS PH W VOLT RACEWAY EXIST.SERV.SIZE 1-9'-VAMPS / PH W -CaOLT RACEWAY FEEDERS NO. SIZE IND. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.30 AMPS, 31.100 AMPS. SWITCHES I __ MOTORS H.P. VOLTAGE PHS- NO. H.P. VOLTAGE PHS $ SIGNS X 000238 ; 77Y DEPARTMENT OF BUIL NQ E CITY OF ATLANTIC$EACH PERMIT INFORMATION " LOCATION INFORMATION Permit Number 4 Address% 1,502 BEACH AVENUE Permit Types BUILDING ATL.ANT. .BEACH, FLORIDA 3223 ' Class of Works REpAI - LEGAL 'flEwSC'iRIPTIONI Constr.. Ty ,s N/A " Lot sk s Section s Proposed Uses s SI-ROLE FAMILY Tcxwrsob p Rua's O Or lIinga 2 O Coder 0 Subdivi*l.on s Estimated Values 077 45- I r�ProV. Costs 00.00 Total F0 # 107, 56 Asount r'a trsr' *1r 50 t War]k STING RESIDENCE TION - . �frPF'L.ICAT # MI FEES . Fla 50 a .r `. r .�t , Addr 1RMIT AVE LlE WATER IMPACT FEE � 9�tt. � C Ni, FLOR I DAP T f*t8 .00 w ' r RADON OASR.S. 00 C [ A H ` OR!'lATIO i RADON GAS 5% 00.00 N�►a►err s LIL z NC3 ;, _ WATER TAP *0.00 ' Acfd ,s.`-^ 1 +.;N' TR>� SNT� -A ` -SEWER TAP „r JACKS L.E'' L EACH," FL3i22SCI HYDRAULIC SHARE � 00 wL3,o+ xsss �� Trp > EINNSPiCT "FEE +�. ENO INEZRIHG �w. r "�t �T]"r �^ -6K P NOTES. I Mr , Q NOTICE—ALL CONCRETE FORMAS AND FOOTINGS MUST Be INSPECTED BEFORE"POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST"BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. `FAILURE YO:COMPLY: WITH THE 11AECHANICS""LIEN I.AW.CAN^f .E3ULT # 1 THE PRORERTY OWNER PAYING TWICE FOR BtJIUDI 14tIVItINITS X11 4TEr 0411 ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT.AND SUBJ REV6CATIC0L VIOLATION OF APPLICABLE PROVISIONS OF LAW. M� " ATLANTIC BE BUILUING,DE " RT NT T N •7,5 0 CITY Or A'TLAN'TIC BEACII APPLICATION FOR ROOFING PERMIT Ross Bremer 246-9228 BUILDING OWNER � PHONE JOB ADDRESS 1502 Beach Avenue I ' LO-I'll 5&6 BLOCK Olt UNIT N '6.3 SUBDIVISION Mandalay i CON'TILAXTOlt Schultz Roofing Co., Inc. PIIONL] 246-2315 ADDRL'SS 216 N 20th Street Jacksonville' Beach 32250 LICENSE NUMBER CC-C036989 EXPIRATION i JOB VALUA'I'ION $ 7,745.00 I MNI'EMALS: Re-roof 1 i j SIGNA'I'UR' OWNER DA'I'S SIGNNI•UItE CONI'IZAC1'Utt """-- -'� i i ' i i FLA. 1967 ,LAWS FS 719.13,. NOTICE OF COMMENCEMENT SEMINOLE FORM 408 (PREPARE IN OUPLICATEI State of Florida 1 County of I The undersigned hereby informs all concerned that improvements will be made to certain real property, and in accord. ance with section 713.13 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. Description of property......1502...Beach Avenue.......:.......Atlantic Reach........................................................................................................... Rea1..Est� ' . . �K ........... .a ............. 1.0........................................................................................................................ ........ ......... .... .............................................................................................................................................................................................................................................................................. General description of improvements....................997roof,,,.,.,..,,.,,. Owner..............................Ross Bremer.............................................. Address.........................•..1502 teach..Ay,QPu.,,,,.,.,,,,.,,.•,,,..Atlantic Beach F1. 32233 Owners interest in site of the improvement........... ' ...Simile............................. .............................................................. . ....... .............................. ..... Fee Simple Title holder (if other than owner) Name................................................................................................................................................................................................................................................................. Address............................................................................................................................................................................................................................................................. Contractor....................Schultz...Roofing..Ca...,...znc.................C CC—0O3.69B.9........................................................................................................... Address.. 216 N 20th Street JacksonvilleFl.Fl. 32250 .................................. ...... ... ... jSurety (if any)..........................................................................................................................................................................................................°.................................... Address....................................................................................................................._..............................................................Amount of bond Name of person within the State of Florida designated by owner upon whom notices or other documents may be served: Name.................................................................................................................................................................................................................................................................. Address............................................................................................................................................................................................................................................................. In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13 (1) (F), Florida Statutes. (Fill in at Owner's option). Name.......................................................................................................................................................... ........... ............. .................................................... Address...................................................................................................................................... .... . ....... ........ ... ... . ...... THIS SPACE FOR RECORDER'S USE ONLY .. .. ... .. ... ................... ...... .... . .................... wrier ay Swor to and subs ed before me this..:.:. . 1......,. ...............................................day of......7 ,r...............................19� . ...... .... .... CITY OF ATLANTIC BEACH p d'" {J�EIL(�ATJ ON_FOR PLIM3I NG DATE f" LOCATION P L U 31 N G F I RN1 �-W• V? ' _!��� ---— --- — I.ASTER PLU•.3ER CITY/COUNTY OCCUPATIONAL LICENSE N0._ STATE CERTIFICATE BUILDER OR CCAWRACTOR TYPE OF BUILDING -- S I NKS SHOWERS Z--LAVATORY __WATER HEATERS BATH TLr3S DI SMASHERS URI 14ALS DISPOSALS CLOSETS V ASHI NG 114ACN!NE `FLOOR DRAINS _/ OTHER AW Le) S TOTAL FIXTURE COUNT NSTALLATI ON OF PLU, 31 NG AND FI XTURES t'UST BE 1 N ACCORDANCE WI TH THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUt,SI NG CODE. .c.►vI-r Ir���c PLR"1IT # F1'!-CLRICAL PERMIT 4t BUILDING PERMIT 1.OR . HE•ET , H QUARE FOOTAGE $ per s. f. _ $ - -- -- GARAGE (PRIVATE/SHED) @ $ _ per s. CARPORT dp @ $ per s. PORCHES @ $ per s. f. DECK @ $ per s. f. TOTALVALUATION DATA. . . . . . . . . . . . . .$ PERMIT FEES TOTAL ALUATION DATE 1st $/S;I".off REMAI DER VALUATION @ SSC? per thousand TOTAL BUILDING PERMIT j PLUS 1/2 THE BUILDING PERMIT FOR PLAN FILING FEE $ TOTAL FEE DUE $ Al PLUMBING PERMIT FEE $ WATER METER SIZE & FEE $ SEWER CONNECTION: SQUARE FOOTAGE FEE $ WATER CONNECTION: FIXTURE UNITS @ $10.00 PER UNIT $ TOTAL BP & PC FEES DUE . . . . . . . . . .$ TOTAL WATER METER CHARGE . . .$ TOTAL WATER CONNECTION CHARGE. . . . $ TOTAL SEWER CONNECTION CHARGE. . . .$ GRAND TOTAL DUE. . . ., . . . . . . . . . . .$ `--- CITY OF ATLANTIC BEACH, FLORIDA a► ApPI.lCAT1aN FOR ICECTR1CA- plilt161T TO THE CHIEF ELECTRICAL INSPECTOR: DATE: — t IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DE$CR�BED, IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM, SAID WORK IN ACCORDANCE WITH THE ATTACHE �'S AND SP'ECIFICATION±3► WHICH ARE A PART HEREOF, AND IWACCORDANCE WITH THE ELECTRICAL REGULATION5I' CODES AND CITY OF ATLANTIC BEACH ORDINANCES. ELECTRICAL FIRM: R T,1 1 N 1 -001 N -,-,ADDRESS: C BLDG.SIZE ' . L —BETWEEN: RES.SY` APT.( i COMM.( 1 PUBLIC I 1 INDUS.1 ! NEW 1 I OLD# ! REM# ADDITION( TRAILER t ! TEMP.# 1 SIGNS SO.FT. SERVICE:` NEW( !' INCREASE ( 1' REPAIR ( 1 FEE co DUCTOR SIZE AMPS COPPER 1 ALUM. TCH OR BR , KER PH W VOLT RACE EICiSf.SERV.SIZE AMPS ' PH 1, W U 2,ZAIOLTJ EWAY FEEDERS NO. , SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL t RECEPTACLES CONCEALED OPEN TOTAI. 0.30 AMPS, ; � 31.100 AMP$. . S�WkTCH88 6 INCANDESCENT FLUORESCENT'&M.V. ITIXED 0.100 AMPB. ovtlt ALtANCrts BELL'PR�SF:" AIR H.P.RATING H.P.RATING CONDITIONING: COMP.MOTOR DITHER MOTORS AMPS OVER EIL#TEAT: KW#lEAIt.. .; VOLTACtE PHS NO. 1 ILP. fOLTAtE, " �rr,, �' jS' "d h aye ? 1 3L T y TRANSFORMERS: UN , w lfl. .. i 2VER w '1S11�A�i1'MENT Of SUIL61N0 CITY OF ATLANTIC EACH. r ddre sd I 02� StACIIA L T a A CAt ATILMit"Ic .BEACH i 'ork �� pn ra Type WAD PPME I cit ITI~,, FAMILY Taazh " ` �. Cady lubdivzsi on: the d Val,Ue: .00 I"mp V,s Cas t Wit I; ' It DeiItAt AND AIooS TION T1:0 ( dr ITER I � _ k. } PLOD I DA 32!33 SEWE PAC0.00 Ph OA' ' AMA OAP "TA IfiPta . did t 'LEVAlk SLx TAP RAO-024ypet 3 "ROS$ C1WCT.I� : 30 BEC..It y `14P ` Ty �IOT�ffi; V `'2 NOTICE--A1.Lf hIDR TE`F6#018 AND FI�OTINGS MUST SE,flog" ;i PE'RMiT VOID SIX MONTMS"AFTER DATE OF ISSU77E a SUII*I;?llI i MATERIA E,"RUBBISH AND QESRIS FROM THIS WORK MUST NOT SE PLACSt?IN F'UBl IC SPACE AIS M"USI ' bLEA C?.UP ANO IiA0'LED AWAY BY EtfiHER CONTRACTOR OR OWNER } REID,COMPLY FA IJ IN TWICE FOR 'Ift PAY 0 FOR I$SUEF ACCORI?ING "T© AFPRUVEC3:FLANS WHICH,ARE PART OF THIS PERMIT:ANS;SLAC f TO,ftE' GA1'itAN.F� 1 V14lATIQN EBF"APPI ICAOL "PR avI It31vS C3F LAW. ATLANtI ..BEACH BGILD'NC DEFAk TMEN'f tl « BUILDING AND ZONING INSPECTION DIVISION CITY OF ATLANTIC BEACH ATLANTIC BEACH, FLORIDA 32233 APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER IMPORTANT ---- Applicant to complete all items in sections I, II, III, and IV. LOCATION Street Address:_ 9" Iy ' OF Intersecting Streets: Between And BUILDING Sub-division II. IDENTIFICATION -- To be completed by all applicants, In consideration of permit given for doing the work as described in the above statement we hereby agree to perform said work in accordance with the attach_ed plans and specifications which are a part hereof and in accordance with the City of Jacksonville ordinances and standards of good..practice listed therein. Name of Mechanical Contractors � �! Contractor (Print) Master � Name of Property Owner � Signature of Owner Signature of or Authorised Agent Architect or Engineer III. GENERAL INFORMATION A. Type of heating fuel: B. IS OTHER CONSTRUCTION BEING DONE ON Is C enc THIS BUILDING OR SITE?_ JI – ❑ Gas--❑ LP ❑ Natural Ig Central Utility - IF YES, GIVE NUMBER OF CONSTRUCTION ❑ Oil PERMIT ❑ Other— Specify IV. MK MMUCAL EQURMENT TO It INSTALLED NATURE OF WORK (Provide complete list of components on back of this form) r1 Residential or ❑ Commercial S' Most ❑ Space ❑ Recessed !f Central O Noor ❑ New Building (M Air Conditioning: ❑ Room JA Control Existing Building ❑ Duct System: Material Thickness ❑ Replacement of existing system Maximum capacity c.f.m. New installation(No system previously Installed) ❑ Refrigeration ❑ Extension or add-on to existing system Q Cooling lower. Capacity q,p,m, ❑ Other-- Specify Q Fins sprinklers: Number of heads ❑ Elevator ❑ Manliff ❑ Escalator (number) ❑ .Gasoline pumps (number) THIS SPACE POR OFFICE USE ONLY (lt.a.l..d) ❑. Tanks (number) Remarks ❑ LPG containers (number) ❑ Unfired pressure vessel ❑ IIoINn Permit Approved by Do ❑ Other — Specify Permit Fee LIST ALL EQUIPMENT AIR CONDITIONING AND REFRIGERATION EQUIPMENT Number Unita DeecripUon Model Number Manufacturer (�jy Agency Appy cc kid i ► r CITY OF ATLANTIC BEACH, FLORIDA FOR ELEC 'RICAL PERMIT TO INE CHIEF ELECTRICAL BMSPC.E,'TOR: IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF,*AND IR ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF AILANTAC MAGM akVNAWES. ELECTRICAL FIRM: E{fIL TH24:'S T ELE. E E U 49 W. 7th S= AT ANIZC EEII3, FL 32233 ,,,/ t NAME_n�l?1sr�_ ADDRESS: Z 6"(2 f V1 —RFD—BOX BLDG,SIZE BETWEEN: RES APT. ( ) ' COMM. { ) _ PUBLIC { ) INDUS. ( ) NEW ( ) OLD { ) REW. ( ) AODITION ( ) IQILER ( ) TEMP. ( 1 SIGNS ( 1 M FT. SER : NEW ( ) INCREAS4>6-- REPAIR ( ) EEE CONDUCTOR SIZE AMPS �'-6260 COPPER I I ALUM. _ ..y Aea TCH OR BREAKER G-C/OZ PH w ,e0 T - RACEWAY EXIST.SERV.SIZE AMPS PH W Z� VOLT RACEWAY FEEDERS NO. SIZE Nd. SIZE NO. SIZE o LIGHTING OUTLET& CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.30 AbtP4. 31.100 AMPS, i SWITCHES INCANDESCENT FLUORESCENT &M.V. FIXED -0.100 Awlrs, ---- APPLIANCES BELL TRANSF._ AIR H.P. RATING H.P. RATING CONDITIONING -'-- CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT at MOTORSH.P. VOLTAGE PHS N0. OV R VOLTAGE PHS MISCELLANEOUS 41111r t a. 3 QEPARTMENT OF BUILDING CITY OF ATLANTIC✓BEACM" oxws, �.� �� - LOcA'TIO ItrCOOR�fATZON Nix rlb+ ddae�� iss-3 1502 ;SEACN AVE. .._, . p s; ! ATEAI T C ,BEACH, FLORIDA 32233 I IE s�st ► MI x` AI:»T A OIlIE; LEGAL: I ECRIP'I ION C rin txe ; `Itt 4.0 Block s Sect i*n s E Pla Book i Purge s 0 t � , Valdes ,a ,.�, , : . !# _ _ ,. OWNER I)IFORNATION OCA 90 z ROSS 'SREt ER R Tot ,I, so#00 Aiddreass 1502 BEACH AVE. iI< tsx r ;s`> lrO.E3# ATLANTXt, BZACH FLORIDA 32233 i Dot .. # Phoss ' Ct ? x,,672 I71 00 E T k o o rss r booting air, hand *r 0. ,» CATION FEES " -- N , . �. � �c - t�.. q IA 1/6 'WATER TKpACT IEE *O. ErE > of ,. A > � ,, K�i �• �,�r *I0, . d i RADON GAS *O 00 ` WATER TAP ��OC ' . .. 'a HYDRAULIC SHARE:' ►t3;= U PELT PEE 0:00 OTHER EU.Ott . VAw �g NOTES. F NOTtCE- ALL C. 'NCRET FORMS AND FOOTINGS MUST Be INSPECTED SEFORE POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE E3tit1.I3ING MATERIAL,RI EBFSH AND;C ESRIS FROM THIS WORK MUST NOT-BE PLACED IN PUBLIC SPACE,AND MUST BE CLI*ARED UP AND HAUL: A, AY RY EtTHER CONTRACTOR OR OWNER. " itLURE T LX #TH THE MECHANICS' LIE-W W. G AN RESULT IN T"IE PROPERTY:p PAIVINO TWICE FOR BtJ1L�1 C`i �1�' !�VENI��IT� " a 1;aSLtI"0 ACCORDING TOA PI Oi/ED PI.AI+tS WHICH ARE PART QF THIS PERMIT ANIS SUBJECT TO REVOCATION FOR VIOLATION OF APPLICAI L 1 'PI Q $10115 O LAW. AUANT ACH BUfLDI T.,' d \tl � m Z 1 � Z N d �o d� `� d .� X), o i 7 GO i 11 � Oy Y 1. Address Heated Square Footage @ $ per sq ft = $ Garage/Shed � /@ $ , per sq ft - $ Carport/Porch @ $ per sq ft = $ Deck @ $ per sq ft a $ t.., t' T Patio © @ $ per sq ft = $ TOTAL VALUATION c $ 1116a1116tal a ua�icm 1st $ (� Raiial.iider Valuation ,&per thousandor portion thereof I ---- - Total Building Fee ADDITIONAL W, PEIULLTS and/or P ` I S-REQUIRED + Filing kee $ I9edhacilcal ? _ O.nreplac6s' @ 15.00 $ r' Plulbing i BUILDING IFEIZMTT HE, $ e?S. 6t I. Electric/Neta i- ---------- ------------------------------ Electric/'m4) Septic Tatzlc BUILDING PERMI.T $ WAIIM MCIER Cf IARGE $ Well . ' Dahumbig fool. SM,,R IMPACT FIEE $ Sign 1 WRIER IMPACT FEE $ Water Comecticm• MISCELIMEOUS $ 1 Sewer Cutulectioci $ Water tbter I;lev.tt•inli Certificaw 1 , GRAND TOTAL M, • ------------------------------------- ----------- ww ww--M---------------------------------------- CAI..=rIONS and/or N(I1TS; !Ir• , I 1.1 � � `.t I�, li Lill ., I I I it�.11�,• !1.. 1+ � A P P L I C A T I O N F O R B U I L D I N G P E R M I T CITY OF 4aarr4? veacl - 9(01a4 REQUIRED SUl3)1ITTALS 7160CF.AN BOULEVARD Each application for building P.0.BOX 26 permit will be accompanied by ATLANTIC BF,ACFI,FLORIDA 32233 two complete sets of plans, including TELEPHONE(9041249.2395 a detailed site plan indicating location of utilities, parking, size of yards and other pertinent data= one set of Florida Energy Efficiency Code sheets= rjecent survey (on new construction) SCHEDULE OF 111SPECTIO11 Reqties Ln for inspecstione will be accepted from 8100 AH until 4330 PH. All inspections will be made the following working day. 1. Footing 2. Rough Plumbing/Sewer CALL IN WITH PERHIT 3. Slab NUMBER FOR EACH TRADE 4. Fr arnirng, Rough Electric, flechanlcal, Top Out Plumbing 5. Insulation 6. Final Inspection/Issuance of Certificate of Occupancy ------------------------------------ BUILDING CARD MUST BE POSTED OR HO INSPECTION WILL BE MADE Pour no concrete or cover any work until building card is SIGNED by *the inspector. You ti will be required to uncover any work that fins not been inspected. Ic 310 fee is required for all re-inspections. '•N 1 LtA- CITY OF ATLANTIC BEACH BUILDING DEPARTMENT INSPECTION REPORT JOB LOCATION PERMIT# SUBDIVISION 0 OWNER NAME 1502 BEACH AVENUE PHONE 2290 ATLANTIC BEACH, FLORIDA 32233 MANDALAY LEGAL DESC: LOT BLOCK SECTION PERMIT TYPE ROSS BREMMER CLASS OF WO(9§04)246-9228 CONTRACTOR PROPOSED USE 5,6 63 BUILDING ALTERATION j WORK DESCRIPTION PROPERTY OWNER SINGLE FAMI1 INSPECTION REQUIRED INSPECTOR �►, CONV T EXTI CA ORT TO A GARAGE DATE INSPECTED gy �' ! APPROVED �„ REJECTED ❑ AM COMMENTSIi PROPERTY DESCRIPTION / r] �CAC�t - T�47C�Ct 71000rAN 130ULM111) Lot ff_ t'4_ Block J1rP Section M.ek.pAL4V 1'.0.13UX2r _ ___--- ATLANI IC IIrAGI1.FLONDA 12231 rubdiviniossI_---[V AMD_,e_�A_V- --- II:LF;{'lIUNF;�pU4)2•iD•2J06 Street flame DESCRIPTION OF WORK or Address s__L,�9 __L7Gf3��__ V ........... If If in a FLOOD HAZARD Flood Zone sc,_ v_A_ ____area complete page 3. Brief- Descriptions rief-Descriptions ClcSC- (ir_J_ _C SNR Or'�" _ Class of Works (flow/Remodel/AdditIon) _ ZONING I1IFORHATION I.., �„ �, •'�,,� Type of Constructions Building and Zoning ZoningProposed Districts_• Uses �2�41Sf/N Chi Estimated Value s_ Exceptions or hat0rialas iC_tss Vwrinncrtn C3relttnllr A/ -4 ~------^-- ------ ---------- • Solid or OQ 1tWClSTy'NS- . --------------------------------------------- Filled C*,0Ve ke Ground t Roof,eX►SttAlL_ OWNER INFORIIATIOt1 hsthod of lire ting s_ ,�QIV ---------- Property _________Property ONner s !LQ,�25 _�-:_!�$�Mfw ------------ ---- Phones Hailing Address------ aent CH--29v�-------------- -------- zips_3•� •_�'3------ CONTRACTOR INFORMATION Contractors------------------------..-------------------- Phones.............. hailing Address____________________________________...,.._.,_-L___-_ _ I _ Zips_____ Expirntion LicenseHumbert......................................... Dates---------__..__ I IIERERY CERTIFY THAT I HAVE READ Alto EXAMINED THIS APPLICATION Allo KItOW TIIE SAME TO B£' TRUE AIIR CORRECT. ALL PROVISIONS OF THE LAWS AND ORDINANCES OOVERHII10 TIIIS TYPE OF WORK WILL DF. CONPLIED WITH, WHETHER, SPECIFIED HEREIN OR NOT. THE ORANTINO OF A PERMIT DOES NOT PRESUME TO f\ 1 w• GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY FEDERAL, STATE OR LOCAL RULES, 11FOULATIO113, ORDINANCES, OR LAWS IN ANY MANNER, INCLUDI110 THE OOVFRHIHO OF CONSTRUCTION OR TIIE "r %'v PERFORMANCE OF CONSTRUCTION OF THE PROJECT. I UNDERSTAND THAT THE ISSUANCE OF TIIIS PERMtT IS �. C �7" C01ITINOF.NT UPON THE ABOVE INFORMATION BEINO TRUE AND CORRECT AHD t11At THE PLANS ACID SUPPORTiNO DATA HAVE BEEN OR SHALL BE PROVIDED AS REQUIRED. 0 A4 Owner Signature __Date `� _Date `:. Contractor Signature___ 1. I . FLOODPLAIII DEVELOPMENT IIIFORMATIOII Type of Development s N jh _____________ --- ---------------------- Flood Zones Required Lowest Floor Elevationt,.______w__ If building is located within a flood hazard zone, a survey must be made AFTER THE SLAB HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above the base flood elevation antnblished for,, that zone. Ho final inspection will be made and no certificate of occupancy will be issued until the survey is on file with the Building Department. COMMENTS: Applicant Acknowledgements I understand that the issuance of this permit is contingent upon the above information being correct and that the plans and supporting data have been or shall be provided as required. I agree to comply with all applicable provisions of Ordinance No. 25-7-11 and all other laws or ordinances affecting the proposed development. Date -_------Applicant's Signature.......................... ---------------------------------------------------- Department Use Required Lowest Floor Elevation ------------------ As Built Lowest Floor Elevation Survey Filed with Building Department - Building Department Representatives page 3 4% 0002190 DIPMENT OR 13UIILDING CITY`"QF ATLANTIC BEACH LOCATION INFORMATION ___--_- P+ rwi t ilTaaxr ! # Acldsr >Ie t 1 032 BEACH AVENUE porwit Ty ATLANTIC TIC BEACH, FLORIDA 32233 CL403 aki AL LEGAL DESCRIPTION Cb*st�r. Typ Lots 5,6 fllca is x 63 swetiont RHOS 0 pr►'�13ir peg t p Subdivision i` MANDALA'Y Eat astod 'fid*l'u, pr 00 Tot*l Aiwa Do :Work CARPORT TO A GARAGE "WF IF 4 APFL2CATIC)H FEES2RrI 7; 28. 15f /14/ dI a WATER IMPACT FEE ��:�� *O. � *CDCA , IDS! S x�P FEE aft► I Aft?x 'am. ., 6e T : y _�... �,,I . ', ovFM RADON 0AE-R..R.S. $0.00t RADON GAO :G 00.00 "*vi s• WATER '1"Aif' *0.00 , Addros t EVER $FCJ. . HYDRAULIC SHARE 4110.00 L�fi �tl► ,t.x " " ",� 1 ax-vitOP'ECT FEE .00 � al�t�. ENGINEERING ��� OO w. NOTES: NOTICE ALL CONCRETE FOjkMS AND"FOOTINGS MUST BE INSPECTED BEFORE POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE 'BUILDINQ MATERIAL,RUSBISH,ANt),D,ESRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE 'CLEARED UP AND HAULED EKY EITHERC ONTRACTOR OR OWNER. "FAILURE Tti GCIIY WITH THE MECHANICS' LIEN LAW CAN RESULT SIN THE PRCOPERTY` �R BAYING TWICE FOR BUILDING IMPROVEMENTS.99 ISSUED ACGCORDINQ TO;APPROVED PLANS WHICH.ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR 0 341F TFON OF APPLICAOL PRCVI Mia CIF LAW. ATL3Uk EP TM 3NT B SURVEY OF LOTS 5 AND 6 , BLOCK 63 , MANDALAY , ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 10 , PAGE 11 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY , FLORIDA . SCALE: 1" = 20 ' JUNE 15 , 1989 CERTIFIED TO: BREMER BRACE OF FLORIDA , •INC. ELLIS , CURTIS AND KOOKER , INC. I HEREBY CERTIFY THAT THE LANDS LAND SURVEYORS AND PLANNERS SHOWN HEREON WERE SURVEYED UNDER 1660 EMERSON STREET MY SUPERVISION PURSUANT TO CHAPTER JACKSONVILLE, FLORIDA 32207 472 . 027 FLORIDA STATUTES . PHONE: (904) 396-6334 GENERAL NOTES : HARLO G. EVERETT , JR. 1 . ) THIS IS A BOUNDARY SURVEY . P. L. S . NO. 3287 2 . ) NO ABSTRACT OF TITLE FURNISHED. STATE OF FLORIDA 3. ) NOT ABSTRACTED FOR EASEMENTS . AEPRODucuctiS OF TINS St?"+'EY FIAT ARE 110T VALID UNLESS SleP;E1 f.,'0 I hereby certify that the property shown lies EMBOSSED WITH THE SDCi7EY00'S SEAS, within Zoneas shown on Flood Insurance Rate Map. Dated7_1f� ^or Community No. �_�� A _CounLy, Florida r 9 9 8 7 QeCAC f 04N•7 /T CO' CN.41N S.•C:i 11Z �V \1.2 1 Is a IY /rt J r/ 9 9. ? /.• TO J .9 • — . 3'/ sr6 1 7. Ci 1� N ?r•/7 Z C 'r 1 •p � 4 9 o ti ti � f:f/S_E�m : (A /Y�' /HOZ 4, � Z v 9 1 117 Flaer FOR OFFICE USE ONLY Date................../U.319 4 CITY OF ATLANTIC BEACH Permit #920.�---Fee$...44;: Valuation FLORIDA ?"? House --_----_ ............... A* ...............................I -------------------•-- .... APPLICATION FOR BUILDING PEOMIT ................................. --------------------------------- -----------------------------*--------------------*...... Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure described. This application is made in compliance and conformity with the Building Ordinance of the City of Atlantic Beach, Florida, and all provisions of the Laws of the State of Florida, all ordinances of the City of Atlantic Beach and all rules and regulations of the Building Department of the City of Atlantic Beach, shall be complied with, whether herein specified or not. The Contractor or Owner-Builder who has been issued a Building Permit is automatically responsible to ascertain that all sub- contractors engaged by him are duly licensed in the City of Atlanfic Beach, Florida. To prevent delay or embarrasment regard- ing intermediate or final inspections it is suggested that a list of sub-contractors be submitted to this office so that licenses can be verified. Date.--•........AXP!�"j _Z _'/ .......... Owner-._.__ ...... -----_-------------_-A d d r e s s F.:-A l v�,r id---------Telephone NQ�vq_q'329 Architect.----• -- -------_-------_-------_Address.-... -------------------------_ ........Telephone No.-----------------........ Contractor Builder----/- -------- -__-----_-..-Address.... ----­-­---------------- --------------_-Telephone No..--------...__---------- - Zone...... Lot No....-_--- --------------------.-Block N ...... ----Sub ....................... -- -------------------.Street-----........---------Side Between-- ...... _ --------- -----------------------a ------------------------------____........__Sts. : K------------------------ Valuation VQ what purpose will building be used.._- ------------_Type of construction- I Dimensions of BuildingC)'k----X_T?-----__Dfill7bluliks of Lot-/ -;Size of Footings_•----- ------ Size of Plers...Z,A-4_---------_----Size of Sill Span in ...Type Roof--- --------------- How will Building be Heated?---_01 ------------ ---------------............Will Building be on Solid or Filled Ground?_. 0 ....... Size of Ceiling Joists-------qlfP---- ----------- Distance on Centers--------- - ------------------------ Greatest Span.------- ------- Size of Floor Joists-1A 0 (--------------------- Greatest Span-------- ------ .........Distance on Centers--.--..... _( / _ Size of Rafters-------------- ---------- Distance on Centers..... l•-- t ..........------- Greatest Span.-..------/0.2---------- --------- This rectangle is to represent the lot. Locate the building or buildings in the right position. Give distance in feet from all lot-lines and existing buildings. REAR LOT LINE Two copies of plans and specifications shall be submitted with application. Inspections required. 1. When steel is in place and ready to pour footing. 2. When steel is in place and ready to pour columns and/or lintel. Z 3. When steel is in place and ready to pour beam. 4. When framing is completed. Q. 5. When rough plumbing is completed,and ready to cover up. 6. When septic tank drain field or sewer is laid but before it is covered. 7. Electrical inspection by City of Jacksonville. or- 8. Final inspection. 100 Note: In case of any rejection,re-inspection MUST be called for after corrections are made. win, 'kool FRONT OF LOT In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in accordance with the attached plans Wandacifications, which are a part hereof, and in accordance with the building w regulations of the City of At ........ ......... Signature of BuilderA.... . .... .............. ------------ ......................... Address_._.._/ I -------., ------------------- Signature of Owner......... ---­-----­ .... .......................... Address....... ...... -----_-_---------------- y , LOUIS C . HOLLOWAY, JR . A R C H I T E C T - I A November 20, 1964 Mr. Arthur J. Craig, Acting City Manager City Hall Atlantic Beach, Florida Dear Sir: This is in reply to your letter dated November 5, 1964, in respect to the building permit for the Walter Fay residence. As you will note by the enclosed drawings, I have revised these drawings to conform to the set-back requirements and have changed the eave overhang to four feet where required . This letter will also act as an affidavit that the structure does conform to the Southern Standards Building Code with reference to the footings, beams, columns and hurricane wind loads . I hope this information meets with your approval . Sincerely, Louis C . Holloway, Jr._' _' 4 A R C H I T E C T LCH:hbr Encl.: 2 315 1 1 t AVE. N. JACKSONVILLE BEACH, FLA. CH 6-51 50 964 � e nr. .Louiz 04, I.101loway Jr 315 — 11th Avonues ITorth Jachsonviille Beach,, Florida 32050 Dear 14r. Holloway T root the necessity Of reta nim to you, for reconsiderntior. ML, Pay's application for rmiat to build a res�i.donoo on is n �, .civ � , tW dala Tho plans prepared by you, which acconpany this appli- cation, nodifi.cati.on as ff1ll ist 1. Maconent Of the pro-posed structure, by nos t libcxul interpretation of Zonina Ordinance of tho City of AtIftntic Beach# mist be in con- fOrn3ty with +ection Tj Poi raph 4(d) the reoto 2* 31�ccri t,W=idth of onves3 or corni.oes, an proposod bui.ldir.� are in violation of Section # : am;: ph 4 (a) of said Zonina Ordinance*. 3♦ Interior structural dcoi n €3.ppeE.fi,rs to be* conamllyq harnonious with the 3outhern. Bui.ldirC Coda and specific anendnicnts thereto L-res cribod by City Crdinanoe. However, hurricsara clips are required on every rafter. I will b -ploased to have an affidavit iron ,you in a,coordar a with Section. 105o6 of the C,ou,t :,ern "')tandard Bui ld.i.r C'ode, T;;,ia affidavit is deened 3.1"portant vfiith reference to bearina. C3ixjx.,bili.tioa of. (a) the footings oup; rtin "x6" wooden posts which au,.)'-,,Ort oonsi.der-a.ble areas of second -story,t ( b) thO "Z64 €U-1-TortinC- {)oots (Q) 'the 4"xl2" wooden, l©rCi— tud.i. whic. ou_p .ort second story joists, (d) stability of the atruotr .when o€b ected to Minds of hurricsane f ' 0=0 Vary truly yon Arthur J. Craiima Aotina City I` .er AJC be �- ��/.mac- _ �2--- , � /;.��' ��.��-�-�'l� �C-�n...�.�.-� .� ' ;L G"":��� _,!/ � ,� � � � r I I DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH,FLORIDA PERMIT No. 6183 PERMIT TO BUILD THIS PERMIT MUST BE POSTED ON JOB Date October 4, 19 84 *00CAC Valuation$ FENCE Fee$ no charge 8635 I A 10/04/8 This permit not valid until above fee has been paid to City Treasurer,and is 1000 subject to revocation for violation of applicable provisions of law. This is to certify that RON BAGLEY 1 has permission to build FENCE AS PER PLANS Classification-RE S IDENTIAL Zone Owned by ROSS BRENER ' Lot Block S/D j House No. 1502 BEACH AVENUE , According to approved plans whi are part of this permit NOTICE—ALL CONCRETE FORMS AND FOOTINGS MUST BE IN- SPECTED BEFORE POURING. �. PERMIT VOID SIX MONTHS „ AFTER DATE OF ISSUE �--� :r---D O Building material,rubbish and debris -Zi from this work must not be placed in public space, and must be cleared up and hauled away by either con. trActw or o ner Building Official. FOR OFFICE PERMIT DATE CONTRACTOR i USE ONLY NUMBER PLUMBING 1 'elf ELECTRICAL SEWER i WATER CITY OF f1 y �� 7!t_�O! F',' .'i0 i'LEVARD ATLANTIC BEACH, i LO}tZL1A 31':;33 TELEPHONE(.'04)(964)249-2395 M October 18 , 1984 '. b Mr . Ross Bremer ✓�f 1502 Beach Avenue Atlantic Beach, Florida 32233 Dear Mr. Bremer , We received a report that the newly erected fence on your property may be in violation of the Code of the City of Atlantic Beach. We have investigated the property and have determined that the fence is in violation of the Code . The Code states that "No owner, occupant or other person shall erect , keep or maintain in existence any fence , wall or structure between the front property Line and the front building setback line exceeding four feet in height" . The exterior lot line of the narrowest side of the lot abutting the street is considered tine front property line . In your case , although your house is addressed on Beach Avenue , the front yard of the property is actually facing Fifteenth Street . The sections of fence along the west property line , in front of the building setback line , will have to be adjusted to a height of no more than four feet , The attached illustration should help you see how we came to this conclusion. . We respectfully request that the adjustments be made within fifteen days from the date of this letter . If you have any questions please contact this office . Sincerely , Rene ' Angers Building & Zoning Department Enclosure v r `IIJ a- � +fr 1 r � i- a 7160CF:A'� NC�IEWARD w �� s_r� J�11 41 j c' PI(.'HIDA .-'_'33 li October 18, 1984 Mr . Rodman A. Luckin 898 East Coast Drive Atlantic Beach , Florida 32233 Dear Mr. Luckin , I h.ave reinspected your property and have daternined that your fence is not in violation of the City Code as I stated in a letter to you on October 17 , 1984. The Code states that the exterior lot line of the narrowest side of the lot abutting the street is considered the front yard, Although your house us addressed on East Coast Drive the front yard actually faces Ninth Street . There- fore , the portion of fence that abutts East Coast Drive is in the rear part of the side yard. A six foot fence in this area of a lot is pe=issible according to the Code . Please disregard my previous letter and accept my appology for any inconvenience it may have caused. Sincerely , Rene ' Angers Building & Z-oning Department cc : f_ile " ( t �7 CIT y OF ✓ °f �1 P.O_BOX 25 J 7� ATI Aw"I7C LEACH,F'k,:, DA 32233 r IFLEPHO\E fXA)249-2395 October 17 , 1984 Mr . Rodman A. Luckin 898 East Coast Drive Atlantic Beach, Florida 32.233 Dear Mr. Lucki.n, The City of Atlantic Beach issued permit ;;16069 to you on August 14, 1-984 to build a fence on your property at 396-898 Fast Coast Drive . I have investigated the property and have determined that the fence is not built according to the City Ordinance nor to the specifications indicated on your permit . I drew a line across the front of the site plan on the permit to inraicate the reaui_ ed 20 ' front setback. It is stated on your permit that the sections of fence in front of this line cannot exceed 4' in height . Your fence -is approximately 6 ' in height in the required '-front setb-ack, Please make the necessary adjustiments to the fence to comply with the City Ordinance .'-` If you have any o questions please contact this ffice . Sincerely , Rene ' Angers Building & Zoning Department I I I � z DEPARTMENT OF BUILDING ' ( 14/ Oi CITY OF ATLANTIC BEACH,FLORIDA PERMIT NO. 06 ( � PERMIT TO BUILD j THIS PERMIT MUST BE POSTED ON JOB Date' ftgUSt19_$(F Valuation$ Fence Fee$ No Charge This permit not valid until above fee has been paid to City Treasurer,and is subject to revocation for violation of applicable provisions of law. This is to certify that RODMAN A. LUCKIN l has permission to build_ Fence as per plans Classification RSRUP-ntial one Owned by Rodman A• Luck.in Lot Block S/D House No. 896-898 East Coast Drive I According to approved plans which are part of this permit I NOTICE—ALL CONCRETE FORMS AND FOOTINGS MUST BE IN- SPECTED BEFORE POURING. PERMIT VOID SIX MONTHS t n AFTER DATE OF ISSUE ----► � 0 Building material,rubbish and debris z from this work must not be placed xA in public space, and must be cleared up andhauled away by eith con- k(� _ tract{or o owner. Building fficial. i FOR OFFICE PERMIT DATE CONTRACTOR I USE ONLY NUMBER I i PLUMBING l j ELECTRICAL SEWER WATER 3 i i CITY OF ATLANTIC BEACH w APPLICATION FOR BUILDING PERMIT Owner -- - = -Address j �^9G -h'�'.� .�<. Phone Architect Address Phone Contractor — Address Phone License Number Expiration Date Lot # Block Subdivision Zoning Street � Between Pztt-2,f- and f 5-5- side 5 Valuation $ Purpose of Building /,fleg Type Const. Dimensions : Building_ y F- Lot Sz.Footings Sz. Piers -- _Sz . Sills Greatest Span Sills Sz. Ceiling Joists Distance on Centers Greatest Span Sz.Floor Joists Distance on Centers Greatest Span Sz. Rafters Distance on Centers Greatest Span - Heating Solid-Filled Ground Roof Flood Zone --- If located within a FLOOD HAZARD ZONE fill out reverse of this application. Inspections Required : 1. When steel is in place and ready to pour footing. 2. When steel is in place and ready to pour columns/lintel. 3. When steel is in place and ready to pour beam. 4. When framing , mechanical, rough plumbing and fire place is completed and ready to cover up. 5. Rough electrical . 6. Final inspection. In case of rejection , reinspection MUST be called SETBACKS for after corrections are made. In consideration of permit given for doing Rear Lot Line "X the work as described in the above statement , ds` we hereby agree to perform said work in accordance with the attached plans and Cn �, C specifications , which are a part hereof, and A: S G a in accordance with the building regulations (D of the City of Atlantic Beach. o r rt o rt T W �6 1 � Signature OWNER"' . $ Signature BUILDER - - Front Lot Line ,r�� riA SiD� w1c.� FLOODPLAIN DEVELOPMENT INFORMATION 4 Type of Development : New Building Alterations to Existing Building Flood Zone Required Floor. Elevation Actual (as bui.lt)Lowest Floor Elevation If located within a flood hazard zone (zone A) a survey must be made after the slab has been oured, certifying that the lowest floor e evation� Vis equal to or above the base flood elevation established for that zone. No Final Inspection will be made and No Certificate of Occupancy will be issued until the survey is on file with the Building Department. COMMENTS Applicant acknowledgement : I understand that the issuance of this permit is contingent upon the above information being correct and that the plans and supporting data have been or shall be provided as required. I agree to comply with all applicable provisions of Ordinance No. 25-7-11 and all other laws or ordinances effecting the proposed developemnt. Date / ,Applicantls Signature ----------------------------------------------------------------------- Department Use Survey filed with the Building Department on Certified Lowest Floor Elevation Required Lowest Floor Elevation Building Department Representative