2405 Mayport Rd JBILL OF MATERIAL
21'-2 1/2"
ITEM CITY, DESCRIPTION
1 36 2" X 1-1/2" X 3/16- #6061 ALUM. CHANNEL MOUNTING CLIPS
— ------------------------ 1
B 2 100 SQ.FT .090 ALUM. LETTER BACKING FASTENED TO ALUM. FILLER
TOLERANCE:± 1/8" ON
S2
---------------- -- ALL DIMENSIONS 3 98 FT. .040" ALUMINUM BRONZE PRE-COAT FILLER PANEL (L) WRAPPED
9 186 LED
SLOAN #CL4-MB RED LONG MODULES
MOUNTING HOLE LOCATI
10 100 SQ.FT 3/16" THICK #2793 RED ACRYLIC FACE
---- ---- ----
c� (D 11 98 FT. BRONZE TRIM CAP (1/8" X 1")
> I ALIGN
'to 12 AS REO'D. PAINT INTERIOR FLAT REFLECTIVE WHITE
13 AS REQ'D. WELD-ON 40 & RESIN BOND
--- ---------- - ---- ----- ----- - --------- ----- -------- -----
17 3 MULBERRY SAFETY SWITCH #30486 - 20 AMP (DOUBLE POLE), UL
ALIGN
18 3 60 WATT, 12V POWER SUPPLY (SLOAN# 701507-WP)
ISOTEC 3 #14AWG (UL) CL3P
21 AS REQ'D
NOTE: ONE 1/4-20 S.S.. ANCHOR BOLT (SEE SHEET#3 FOR OPTIONS)
22 36
DISCONNECT
SWITCH PER 23 36 1/4-20 RIVNUT W1 3/8-16 HEX HEAD BOLTS AND LOCK WASHER
SEAM (PLASTIC BREAK) —
(SEE DETAIL#2) POWER SUPPLY 29 AS REQ'D RIVET, ALUMINUM #43, 1/8"0 x 1/4"
31 AS REQ'D U.L. LISTED CONDUIT AS PER LOCAL CODES
32 AS REO'D PRE-DRILLED 3/8-0 DRAIN HOLE
SCALE:3/8"=1'-
LETTERS LAYOUT COMPUES WITH:
33 AS REQ'D. LOCATION OF ELECTRICAL & U.L. LABELS
2007 FBC, 2009 SUPPL.
34 AS REO'D. U.L. WEATHERPROOF 3HOLE OUTLET BOX #IH3-1-LM
— ---------------- ASCE7-05
AREA/WEIGHT _35 AS REQ'D. IDEAL #30-362 UL LISTED WEATHERPROOF WIRE CONNECTOR
#8 S.S. FLAT HEAD SCREWS
36 AS REO'D.
SIGN SQUARE FOOTAGE: 37 AS REO'D. IDEAL #30-146 PRE-INSULATED CRIMP CONNECTOR, UL
100 SQ. FT 38 REQ'D. U.L. 2 X 4 GALV. STEEL HANDY BOX
f ESTIMATED SIGN WEIGHT: 43 AS REQ'D. 1/2 0 -1-C.-S, NIPPLE (REGAL #1791) W/1/2"0 LO-1, 1.1-11-1-1
400 Lbs
% B.0.M.
am B. Zeeveld, PE
FL. Lic. # 61169
P.O. Box 800088 TO LETTERS
21
ROSWELL, GA 30075-000-1
�7
LED LIGHTS TOTAL
(828) 692-7681 0
���38
17 186 0
# OFLED 46 18 17 24 14 15 16 19
A -DC POWER (1)60WATI (1)60WATT (1)60WATT 3 X 60 WATTS NOTE:
C SUPPLY 12V P.S. 12V P.S. 12V P.S. POWER SUPPLY THIS SIGN IS INTENDED TO BE INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTS OF
21
AMPS LOAD 1.0 AMP 1.0 AMP 1.0 AMP 3.0 AMPS ARTICLE 600 OF THE NATIONAL ELECTRICAL
CODE AND/OR OTHER APPLICABLE LOCAL
CODES. THIS INCLUDES PROPER GROUNDING
CIRCUIT 1 X 20 AMP CIRCUIT -20 AMP CIRCUIT
AND BONDING OF THE SIGN, cc FROM POWE jLqv
SIGN INTERIOR TO
NOTE: BE PAINTED FLAT 17
ENAMEL WHITE FOR USE WHITE SILICONE TO w-
120 VOLTS ELECTRICAL SUPPLY WALL
THESE DRAWINGS ARE THE PROPERTY OF ICON IDENTITY SOLUTIONS. MAXIMUM REFLECTIVITY 1 CONCEAL LIGHT LEAKS
THEY CAN BE USED FOR REFERENCE PURPOSES ONLY BY WALGREENS, THIS SIGN TO
BEAR THIS MARK NOTE:
HOWEVER THEY CANNOT BE USED FOR THE MANUFACTURE OR
NOTE: NOTE: WARNINU
INSTALLATION OF SIGNAGE BY ANY COMPANY OTHER THAN ICON IDENTITY CHANGE IN WIRING POLARITY ONE 60 WATT POWER SUPPLY p
UI QUANTITY FOR POWER ELECTRICAL FEED'HOLES -0 ERATION RU
Lmkrdu*We NS UP TO 90 CL4 LONG
SOLUTIONS. USE OF THESE DRAWINGS FOR ANY PURPOSE OTHER THAN SUPPLY REFLECTS SINGLE & FASTENERS PER SIGN WILL CAUSE NON
OF LED SEGMENTS RED LED MODULES (FOR WIRING DIAGRAM, SEE DETAIL#1, SHEET#2)
REFERENCE IS STRICTLY PROHIBITED BY ICON IDENTITY SOLUTIONS. ELECTFOC 660H SIGN INSTALLATION ONLY MANUFACTURERS CRITERIA
SCALE:N.T.S.
IREF. #
DETAIL–DISCONNECT SWITCH 2
LED CHART, SIGN AREA & SIGN WEIGHT
F,
I 'PROJECT: JOB # APPROVED BY / DATE
REVISIONS
4 ENGR. vIGR.:
A
No. DATE: BY: DESCRIPTION 2480 GREENLEAF
0 OPR.MGR.:
ELK GROVE VILLAGE DRAWN: ABP
_�.r J62
gr-- PIOJ,MGR.:
ILLINOIS 60007
cc on LOCATION: DATE: 03/07/08
Aj
Identity Solutions SALES MGR.:
(SLOAN LED) SCALE: AS NOTED
W6&54 V/
DRAWINGS ARE THE EXCLUSIVE PROPERTY OF ICON IDENTITY SOLUTIONS INC.,
ENGINEERING DRAWING TI TLE: UM. SCRIPT LETTER SET 61 Al SHEET #
ANY UNAUTHORIZED USE OR DUPLICATION IS NOT PERMITTED. 21 '-2 1 /2" ILL rFLE- WAL25 S 1 of 4
MULBERRY DOUBLE POLE SWITCH WIRING DIAGRAM
WIRING GUIDELINE FROM MANUFACTURER TO
SAFETY SWITCH MULBERRY H TO LED'S
MINIMIZE VOLTAGE DROP )OUBLEPOL IN LETTER
(8FT MAX. DISTANCE FIRST WIRE
DISTANCE FROM POWER SUPPLY TO GAUGE SWTCH
1 0 BLACK -
TO FIRST LETTER) LETTER 14 GA. WIRE
1FT TO 15FT #18GA. WIRE PRE-INSTALLED IN 18
POWER SUPPLY
I
16FT TO 50FT 014AWG 5FT OF 18_AWG 14 TO RED +
51FT. TO 125 FT #12AWG + 5FT OF IS AWG 12 # 14 GA. WIRE
126FT TO 20OFT #IOAWG + 5FT OF 18 AWG 10
FROM JUNCTION BOX ALL SPLICES TO BE
#14 GA. WIRE
CONTAINED IN UL
LISTED J-BOX
FROM JUNCTION BOX
F #
#14 GA. WIRE
—-----------------------—I
TO NEXT
I LOCATED IN ELECTRICAL EQUIPMENT ROOM I ---------- �T
I I LETTER
A C
I V:::4��To DC
POWER (8FT MAX. DISTANCE
SUP�
PLY
NE 120 LINE 12V (LOW VOLTAGE) 10 GA. WIRE JUNCTION BOX
I LINE 12V (LOW VOLTAGE) #10 GA. WIRE
NEUTRAL SUrl-LT TO SAFETY SWITCH)
GROUND LINE #14 GA. WIRE
_j —------------------------------—
SCALE: N.T.S_
REF. #
DETAIL TYPICAL WIRING DIAG.
Pc>pulating thi-a Channet Lettt-_r
Popu!atinq a channel letter with ChanneLE04 is as easy as pee-lino the liner off 11he
mounting tape anid FiTrnly pressing the light mcd.ule:5 in the desired locations.
NOTF Utindisig s%,�,.ace 15hcauld be clean and dry. 5' 2' FIELD VERIFY
To Adetermine wtiere the Pght modules should be placed and how many t43 Use. Sloani-EiD WARNINU
CHANGE IN WIRING POLARITY WILL
rjfft-rs P� following guideflness: (Pesults may vary 13ased an len�s seiectiOn and le.11-er 0—
construction). CAUSE NON-OPER TION OF LED
1. 4--haars-e-LE-0-4 modules are dtasiqned to be place in roves_- 0— SEGMENTS
a. <_-hanne]LED4 Long rnodules.shc�uld havo a 2' spacing b�etwe_en modu5es 36
withi n the row, This will resu it i n 2 modules pe r f4D-ot.
b. Ch2nneIEC4 Short ni-odules should hasoe a 2.5' spacing batvwOer-, ry%oclules 11
within the row. This wifl result in 3 moclu5es per to-at. NOTE: CL3P CABLE SHALL BE
EXPOSED BETWEEN LETTERS.
C-001 C-0.1or's (8gue and 0�reen) should have- a spacmng of 1
THE CABLE SHALL BE SUPPORTED
between rnodules,wilh in %be rove. This will result in 3 crx>ctulfts per fooll. tOMPLIES Wff H:
AND SECURED AT INTERVALS
2. Ch-annek-E.04 modules are designed to cower a stroke width of 5- In a chanrel letter
. ,.2007 FBC, 2009 SUP NOT EXCEEDING 6 FT. SEE NEC
oetter deplih 44'lo 10') li-etters with a 5" stroke vAd4h or smaller ShOlk-Ad have 0 P'L.
4,-.f ChanneLE1>4 moclutes. L&Ixers with a stroke wi-dth larc 725.61(E)(7), TABLE 725.61
ger than S' would have
m"lliple rows placed 4- to 5' an center as needed tu cover the entire stroke widkh. ASCE7-05 AND 725.82(A).
3, V'0-)en all cnad"Ies Uye ill place, the sac,,3nclary a43tput frorn the ip�;iwar supply cfArk be
%-, .!9 'f %
'ronnecled, "u hople le2ters In a sign car-, b�e connected to th e power su pply in po raile 1 31 %'. 4(1,.. % �0'
or-series, However. for targe letterswillh more th an 45 mc'dule 5 or lette rs Wired in 9
a--
series w")n more than 45 n-,ocivies, oonrl.-ect the PQ.."T r�upply leaci to middte of
the seres insteall of 1he enJ- Use UL listed wire nuts or UL flated Insulation 2
Displacement t--annectors to make this ciDnrtectlon and to cap off the OP-en ertcls. of
to
t h r--,w
Oy_-
GROUND WIRE FASTENED--
wor floryk
e,nd:'v�sw forWilham B. Zeeveld TO ALUM BACKING
P'o cuanPuse I PE
_%upply. make
k, - rl"Ls-
fT)
connectforw .,\,ILh
N X
FL. Lic. # 61169 U-1__ LISTED BUSHI
J-BOX (U.L.)
NV'ARNING. C�HECK
RED TO
P.O. Box 800088
RED I BLACK TO
15I.-ACK, 0N1.y OSWELL, GA 30075-OOC 1
IDEAL #76B WIRE
OR (U.L.)
13 CONNECT
(828) 692-7681
> 35
+
36
2.5" - Channel-ED41-Short
;T NE T
0
2.0 - Chri;nneLEr,)4 If thi's had rnoep than L11 TTE�R
@_ 21
45 mo�JuLes in it, ya;u %,vol-ALd ISOTEC CL3P
-connect the power 5%..Ip-ply
29 VFROM POWER S #14 WIRE
tend in the rnictrtte of the OURCE
....... strand instuad of tluz ond- OROPREVIOUS LETTER
SCALE: 3"=I'-O"
[SECTION
Fiig,� 2 2-4" Charsrwa-1.tetteir with 4" strt>ke popuLated voth one strioke of ChanneLED4 4".
—-%l 0
PROJECT: APPROVED BY DATE
REVISIONS
ENGR.MGR.:
No. DATE: BY: DESCRIPTION
24BO GREENLEAF
0 OPR. MGR.-
W, WN: A3P
ELK GROVE VILLAGE DRA
("00
ILLINOIS 60007 PROJ.MGR.:
W DATE: -0- 3/07/08
R,cc aa n .
'Jq Idantity Solutions SALES MGR.!
SCALE: AS NOTED
DRAWINGS ARE THE EXCLUSIVE PROPERTY OF ICON IDENTITY SOLUTIONS INC.,
ENGINEERING DRAWING TI TILE (FILE WAL2561AI SHEET # S 2 o
: LED LETTERS
ANY UNAUTHORIZED USE OR DUPLICATION IS NOT PERMITTED.
-----------------
0 FLEXIBLE NON- METALLIC SEAL TIGHT
CONDUIT FROM LETTERS THRU WALL
(0
%
9
ISOTEC 3 #14AWC (UL) CL3P
F-- -----
--7 UL
UL I I J-Box I J-BOX
BOX_ ___j
DOUBLE POLE
DOUBLE POLE
SAFETY SWITCH SAFETY SWITCH SAFETY SWITCH
0
POWER SUPPLY #2
POWER SUPPLY #3
PR
COMPLIES NTH:
2007 FBC, 2009 SUPP
ASCE7-05
TOTAL
LED LIGHTS
PE
William B. Zeeveld,
# OF LED 46 18 17 24 14 15 16 19 17 228
I FL. Lic. # 61169
AC-DC POWER (1)60WATT (1)60WATT (1)60WATT 3 X 60 WATTS
SUPPLY 12V P.S#1 12V P.S.#2 12V P.S.#3 POWER SUPPLY
P.O. Box 800088
AMPSLOAD 1.0 AMP 1,0 AMP 1-0 AMP 3.0 AMPS
ROSWELL, GA 30075-0001
CIRCUIT 1 X 20 AMP CIRCUIT 1-20 AMP CIRCUIT
(828) 692-7681
I SCALE:1/2"=l'-
DETAIL WIRING DIAGRAM IREF. # 2
rp-
ROJECT: JOB # APPROVED BY DATE
REVISIONS /3 o Z6 1
ENIGR. MGR.:
2480 GREENLEAF
0
OFIR.MCR.:
ELK GROVE VILLAGE DRAWN: ABP
ILLINOIS 60007
/o(q PROJ. MGR..
DATE:
Ac,.(on
No. DATE: By! DESCRIPTION
03/07
Identity Solutions
1ALES MGR.:
SCALE: AS NOTED
LED)
DRAWINGS ARE THE EXCLUSIVE PROPERTY OF ICON IDENTITY SOLUTIONS INC., . ............
GINEERING DRAWING TLE:
EN
TI
ANY UNAUTHORIZED USE OR DUPLICATION IS NOT PERMITTED. 21 '-2 1 /2" ILLUM. SCRIPT LETTER SET WAL2561A S 4 o�Ej
F
ILE: SHEET #
LED
LCT-1 EZG
Ye:LociTy i4e) Mli-ix wito-C) FkessureE 7;9
A 7� f:—I VVT, =1:2 0
M Ay, Fc 1w G 7C>,)
k7e&
LIL S f IV
TCTHfLIIIAVC��a '?50 i�� A,F- cc-I's(M itc
(0-04q)(I octV) 5600
03 9 A t T30c--IS)
'3 1,36
Wuputs lily":
2007.FBC 2009 s' UPF"L
ASCE7-05
William B. Zeeveld, PE
FL. Lic. # 61169
P.O. Box 800088
ROSWELL GA 30075-0001
(828) 692-7681
Not
Populating the Channel Letter
Popu��at in�a r-I a rine I Lit,or *iib 0)an rkp-LEE C4 I-- as ;--j as y as coe I iwg I h e I in e;-off 14-1 C
MOUnling tape anfJ firmly'pressing the lightm-c,41u.les ri the desired lacat�ona.
NOTF Bundioaq s-urfa,.-e onuld be cl�!an and dry
To d-atermine vMere the hghl modules shotild be place d and iiQw many tj v5p, 510 a n LEEJ
affi�rs ,�w fullmAing quiddellirws- �Rpst)Rs moy vary base.,d o;j lons setedirin and lelie7
Fn
con Stru r..1.
1. (�harinoLEE;-4 rnodulas afo des qnc.d lo be place i.n rows:
:I. Channe'-EE,4 Long nmlol-,ules should ha-�e a 2' spacing It hi,,e�en niodu!es
within, W�e n7vo. This vtifl resull in 2 modu,'ies perfwt,
b. Chanr�y-,IEC,4 Snort ergadules should have a 2,51 spacinq biatv.�on crx3ouler,
within the rovv. This wid resull in 3 modd5es per fc-at.
�R�ue and Cirper") sho-uld h,�yp a spamng
Of 1,S'
be tvveen wo du le s vvili-i in th a row. This w,11 result in 3 woaulcis pe�foot, AC TO DC j (-) TO NEXT LET.TER
LINE 120V-
2. ha rt-%eL EN module s am de sign ed lo ciave!-a stroke w�dth of 5'i n a cha n nel lever POWER
U7RA[
LL1uP'—'P1L,-,y—]
(-'Rtter deplh 4'1k) -,eitp-rs wiiti a 5' slroke-N,,-zdlh oi smaNer shaqid haye,i�-ne rovv
af Ch,;ar-,neLEC-A rnodu`&s. 1-clieTs veth a estrf;ke iclth larq,3 veian 5� v.ould riave
multple mwz.pla-led 4"to 51 on-entec ast naeded tc cover tt�e entira si,7ok-1 v;jdth. i-)F- A 1 1 T V L): A 1 \A/!F-'lN I F)1 A I SCALE: N.T.S.
I.V)en All q�odules ali� in plw:e, the ser-undary mitput fr3m the, pov.,Fr!.wpply �ar)b F
F�
conriecied Mull;Ple l0te,-,s in a sign car)IY& conciccled to IhU pOWC2"supply in paraflel
2' F EL D V 7-
�ir 5erip s. Hb-oVFJ-VeF. for?arge lett-r.5 w1ih mo. re th an 45 MG 11.0e 5 Or 14�1 te�r,5 vwj,-r-d �n
rribre fhan 45 rr-ndulHs cc�or�ecf the Pmver Supply lead to rnldd,p of
the ser--s insteal cif!he end. Use UL liMed nuts !w UL�-,isled CHANGF IN WIRING POLA-RITY WILL
CAUSE NON-OPERATION OF LED
Dis pl-ace ment.11.-on n ern-,)rs ta maka this c-7,n Per.1 ion arizt to ca p aff the ope n er ds of' SEGMENTS
tile PaA. (3D6 —-----
COMPLIES WITH: U) ------------------------------------
Cap ell"15 of
I NOTE. CL3P CABLE SHAU BE
k, EXPOSED N"
SL ALL HE SUPPORTED
2007 FBC, 2009 SU�P'L. 9ETWEF LETTE�RS.
7 ulnu5ed v;�i-H-5 ix-:JnjP, (I-,, I It-, I
Sjp:Ay. 'HE CABLE
ASCE7-05
with
1 AND SECURED AT INTERVALS
NOT EXCEEDING 5 T. SH NEC
-ABLE 725.61
,vre I . 4 - I I
7 2 5.6 1'E)(7),
Wj!�R,N�NO: C HE CK. AND 725.82(A).
po"LARI t Y. R L 1)1�1 0
K r 9 E,R SOURCE
PED / B�-,' William B. Zoeveld, PE
FROV PO
OR PREVIOUS LETTER
fls 1, C K C,N1 Y
FL. Lic. # 61169
P.O. Box 800088 GROUND WIRE FASTENED
TO ALUM. BACKING-
#A
OS�ffil-L, GA 30075-0001 1 1 To NEXT -FTTER
0
betv�een mc.&Les i--,: 1--Z (8281692-7681
2,5 Criannei-ED-4-S.'Kirt
10'thi� b�,Ll;.��;: had rno�,u 1-4--tri I
�r, it, w,,j ,-,,c�uld 35
45 mcq�ulf'
connect the per-vei 5.,JEIply
cl�
lead ki Lhf-mji-01H ol (hp
32
29
Fig. 2; 24" Chaw-w-1. Iette;r wft-h 4' siltroke pDpulated one stroke of Channe'LED4 44',
NOTES ISCALE: 3"=l'-O"
SECTION
'R�F. #
REVISIONS rPF?OjECT:
I APPROVED BY DATE
No. DATE: BY: DESCRIPTION ENGR. MCR,:,
2480 GREE.NLEAF
0
(_7
j - O�R. VGR.-
07/24/0? KM AS PER ENGINEERING REVIEW ELK GROVE VILLAGE DRAW,:
L-)
ILLINOIS 60007 P** el
�7,/3 0/0 6 PRO'. VLR.
N: ATE:
co .n. , D
Ident!
ty Solutions
OT SALL-SMIGIR.:
SCALE: AS N ED
DRAWINGS ARE THE EXCLUSIVE PROPERTY OF ICON IDENTITY SOLUTIONS INC.,
ENGINEERING DRAWING
�FILE: SHEET # S 2 0 T' 2
ANY UNAUTHORIZED USE OR DUPLICATION IS NOT PERMITTED. TITLE
18" 1-1-�ARIVACY Ll-D, 1 ET7 E R & WAI I 753E
-DAN)
t
FH<3TD L-b L-C-TTMS
WA-Le-trZF �j54r/_;30
rz
- ITY -
4r
15161/C; 6 Ts
b W is i c--t m
T 75
7:-- 4$3
LO sur! ss am-e
M Fc
ku�cvz
ViU UJKL VC-lu 67 (tvb'
rig
7%
ToTot 15 A.SoL�
A L-ow� v5 cotc4q)(Iooc�o
t-
( 145 A
(f G 14
COMP40 VATH:
2M7 ,Sc
SUHR4&
William B Zeeveld, PE
FL. Lic. #-61169
169.
P.O., Box-800088
ROSWELL, GA 30075-0001
(828) 692-7681
Populating theChannet Letter
Populating a channel letter wilh ChanneLED4 is as easy as pealing the line�,off the
mounting tape and firmly pressing the light modules in the desired locations.
COMPLIES WITH:
NOTE.- Bonding siurface,s". uld be ellean and dry
2007 FBC, 2009 SUPPL.
To determine viliere the light modules should be placed and Pow many to use,5loaflLED ASCE7-05
Oar!;me follovring 9"Idelir es� (R.ssufts mo,
vary ba�ed on liatins setieclion and letter
construc6on).
will-
jam-13.2le
1. C-hannojLED4 modulas afe designed to be place in roviss,
a. Channel-ED4 Long Imcidules should have a 2; spacing hetween modu!es FL. Lic. # 61169
within the row. This will result in 2 modWes per foot.
P.O. Box 800088
b. ChannelED4 Shartmodules Should h2lVe a 2.5' spacing between criondules
within the row. This will result in 3 modwes per foot. 5' 2. FIELD VERIFY ROSWELL, GA 30075-0001
CharneIXD4 Cool Color�(Biue and Gr-een) sho�,jld.havg a sparuko of 1,5*
bat�ween frkduleswilh in the row. Thl;s will result in 3 mkiJulars por fool,
(828) 692-7681
2. ChanneLED4 modules ape designed to elavef,a stroke wiAh of ST in a channel letter
0__
(tetter dep1h C to 10) Letters witli a 5' slroke ved1h or smal-1'er shOWd have one row
of Channal-ED4 modtj�es. Le*,iets v.0 a strcke width large,than 5'wj'uld have
7'
multtple rcivvs placed 4"to 5'on center as rieeded to cover the en*-stroke widl.h. ____77)
r
a, 1.,Vberi all rrmdoles are in place� ',tie secoridanj aotpLit from the,povier svpply cari be
connecied. Multiple 10(ofs in a sign can bfj connected to the power supply in para4el 19
W series. Hm%ever,for?urge letters with more than 45 rrusdules or,letter5 wired in
OriAs�Mjh rnore than 4.5 =dules, obnooct tht�pavm-e supply lead to 1h8 rildd;p o(
the seCpes instead of the end. Use UL listed wire nuts or UL listed Insulation
Displacement Connectors to make this connection and to cap uff the op-en ertcls.of
tOe row�
Cap ends of
Power florquovial. 4,
unwed vt�res using,
�-Uppl;. make
wil�e nuts-
connection, with
Mire nl_45, ),k
L--------j
T
WARNINI75. C,HECK
i L--------
POLARITY, RED TO
RED / BLACK TO
I I L
Oy_- E�I
BLACK ONLY
A�,
013-
t L
C? W Z
Reconiwieark-,d spacin�,
betvx-ein modules is: 23
2,5"- Channel-ED41-Shoft
0 .
2.0"- ChanneLE04
Lonig
1( tills 18U.c.,r had tnw,u Lhan
1,5" Channel-EIM-CiXil j
45 moduLes in it, V
ou would
35rop
`7�� � connect the power supply
lle(ld in the njifidtip )f the WARNING!:
11
CHANGE IN WIRING POLARITY WILL
SII a rid inst oad of thx-, ond. CAUSE NON-OPERATION OF LED
SEGMENTS 21
Fig, 2 24'Chanwi letter with 4" stroke populated with one stroke of ChanneLED4 4'%
SCALE: 3"=l'-
NOTES SECTION
I REF.
r- -I rp
REVISIONS ROjECT: 'JOB # APPROVED BY DATE
No. DATE: BY: DESCRIPTION ENGR. MG%,, 7
14111 ELMHURST RD.
0
ELK GROVE VILLILGE
OPR. MGR.-
DRAWN: AH
7ao"n)- I
DATE: 110J. MGR.:
Identity Solutions
ILLINOIS 60007
LOCATION 07/21 /07
1A11S MGR.:
SCALE: AS NOTED
DRAWINGS ARE THE EXCLUSIVE PROPERTY OF ICON IDENTITY SOLUTIONS INC.,
ENGINEERING DRAWING
(LTL E
ANY UNAUTHORIZED USE OR DUPLICATION IS NOT PERMITTED. SECTION (SLOAN) FILE: SHEET #
WAL2290A S2 of 2-
BILL OF MATERIALS
NOTE. N OTY. DESCRIPTION SPEC.
.126* ALUMINUM SHEET ALUM
SIGN IS MADE IN 3 VERTICAL I AS REQ'D
PARTS TO FIT IN 24" X 2-4" 2 AS REO'D .125- ALUMINUM S"EET ALUM
A
OPENING. PLASTIC FACE TO
AS REqD I.-J5 ALU41NUM.ANGLE ALUM.
5'-2 1/16' BE:'��bLLLO MA)(. 02d" AbLL, 6 AS REO'D 1 1/2".X 1 1/2' X I/a' ALUMINUM ANGLE ALUM
AS REQ�D 4-ALUMINUM EXTRUSION RACCWAY w/.050' ALUM. COVER ALUM
2 1 0 AS RE07D 2'ALUMINUM EXTRUSION RACEWAY wl.050" ALUM. COVER ALUM
10 AS REOt OSO*ALUWNUM SHEET4 WKITE PRE COAT 3003
3003
1z AS REO'D 0!?Ir ALUhINUM SHEET,REAR ACCESS PANEL
-----—-----------—-- 40 24 sq�ft. 3/16' THK. J732B VMITE TRANSLUCENT POLYCAREIGNATE
SEAM
47 UNION.U.L AND ELECTRICAL LABEL LOCA*AON
1/2.
51 AS REq0 3M 13630-53 CARDINAL RED VINYL FILM 3M
-T---(D
60 5 F72TI2 CXKO.LAMP(12 000 HR. RATED AMERAM UFFE)
61 1 BALLAST: ASS-1240-46-BL-TP (ADVANCE)
It
62 5 LAMP SOCKET KULKA PB2GDr
LAMP SOCKET KLAXA 9583ODF
64 1
rA I t/2- X 1 1/27 X 4- ELECTRIC IDOX
65 1 SAFETY SWITCH (WESTRIM #3805
t 7. SINGLE POLE. 20 A)AP$)
S/3
67 1 UL,USTED CONDUIT AS.PER:LOCAL CODES
70 AS REO'D #10 SS X.3/0 COUNTERSUNK SCREW 18/8
AS REWD SCIR
1 71 CW, HEX WASKR.TEX. #8 X-3/4". UNSOLTED.ZINC FINISH 18/8
73 ALUM STUD wl NUT AND SEALING WASHER -
AS REQD 11/4-20
75 AS RE
4.
iYQ 11/4-20 HEX BOLT wl NUT, WASHER AND LOCK WASHER
SEAM I
---------—-
--------- -
It---- .
S3 "1 8 3/4'
WALL
COMPLIES TH:
7'
Ike-
Z!
V-1*1/27 V-101 V-10 1/2' &L
2007 FBC, 2009 SUPPL. A.*% -0
ASCE7-05
0 lap=
/"0'z-
NOTE!WALL OPENING TO BE
.01
William Zeeveld, PE /Z
USE WITE SILICON
ELECTRICAL E To If
CONCEAL LIGHT 1-1::A:KDS FL. Liv.4 61169
AREA/WEIGHT THS SIGN To
LAUPS 1(5) F72T-12 C.W.R.O. SQUARE FOOTA�._ ULM( fHS MARK
P.O. Box 800088
BALLAST ILI,ASEI-lZ40-46�BL-IP SIGN
SIGN INTERIOR TO BE
'3!0 sq. ft. PAINTED GLOSS
AMPS '!
b�* ANCE:1 1/16'ON ENAMEL WHrFE FOR
ESTIUATED SIG14 WEIGHT; ROSWELL, GA 30075-0001
V.A* 1120 VOLTS WATTS 462
MANNIUM REFLECTIMTY
3DO Lb. ELECT11M SM IMENSIONS
CIRCUITS 11-20 AMP
(828) 692-7681
3"Kii N.T.S
ELEVATIONS FRAME CROSS SECTION DETAIL
rJOB I
REVISIONS ft,OJ.ECT-
'13,0 Z,6 APPROVED BY DATE
140. OA1r_- BY. DESCRIP nON DM himu
1410 ELUHVPZr 1w.
C7 um.;
ELIE GROVE 'KUAGZ
../.3./07 MI ADD REVISE PER CUSTOMER RE:'AEW DRAWN: C R
600137
icon DATE: 07/18/07
L I
D u"
SCALE: AS NOTE
A7741t)7Z
DRAWINGS ARE-THE EXCLUSIVE PROPERTY OF ICON IDENTITY SOLUTIONS INC.,
ENGINEERING DRAWING
ANY UNAUTIJORIZED USE OR DUPLICATION IS NOT PERKITTED. TITLE: 6'-3 1/4" X 5'-7" ILLUM WALL SIGN LE�
WAL2194B SHIEET I S1
of 31
.............................. ..................................................................... ....................... ..............
=:arc
FL Cp 11
5cA
SECTION A
COMPLIES WITH:
2007 FBC, 2009 SUPP-L.
A
ASCE7-05
Ej
.......................
William B. Zeeveld, PE
FL. Lic. # 61169
75
P.O. Box 800088
ROSWELL, GA 30075-0001
(828) 692-7681
E3
SECTION IREF, A
REMSIONS I-PROJECT.- )Qu 1/ 7 APPROVED BY DATE
_3
13 Zg
DW WR
DATE: BY: DESCRIPTION
1418 ELMHUIM RD.
OPR.M(X:
A. og/3o/-, Mj ADD REVISE PER CUSTOMER REVIEW ELIC DROVE WILLAGE DRAM: CR
iconILUNGIS 60007
. 07/18/07 a m Gwft
j LA u'J'
Tr
C
IdentIty Solutions
SCALE.- �AS NOTED
DRAININGS.ARE THE EKCLUSIVE PROPERTY OF ICON IDENTITY SOLUTIONS INC.,
ENGINEERING DRAWING W
ANY UNAUTHORIZED USE OR DUPLICATION is NOT PEamrrm. TLE- 6P-3 1/4" X 5'-7" ILLUM WALL SIGN Flu. W�AL2194B SHEE7 S3 of 3
................ ...... .......... ........... ..........
CD
I pi
ca
V.,
Will
x N
Ol
'NIL,
CD
VI to
cc
New
m
C)
CM
I*x
tj
Fn
:3 Cc
EQ Lu tw
41 cc,
ul
CA
�sz
P4
lb
LAYOUT UTILIZES THE GW3'S SNAP AND SLIDE CAPABILITIES
4'-0"
NOTE! CL3P CABLE SHALL BE
V-8-
EXPOSED BETWEEN LETTERS.
7/16"0 MOUNTING HOLE IN GUSSET THE CABLE SHALL BE SUPPORTED
NO HOLE IN SIGN BACK AND SECURED AT INTERVALS WARNINQI�
UNTIL INSTALL NOT EXCEEDING 6 FT. SEE NEC CHANQE IN WRING POLARITY WILL
CAUSE NON-OPERATION OF LED
725.61(E)(7), TABLE 725.61
SEGMENTS
AND 725.82(A),
LED LED LED LEO LED LED LED
FIELD DRILL J*O HOLES
031 0 w G31 al 031 031 Or AS REQ'D FOR MOUNTING 5 9/16"
5.
CANOPY TUBE
LED LED LED
-ED LED LED LED
(LOCATION SIZE MAY VARY)
031 G31 031 03'1 G31 031
ILIE LED LED LED
I IED LED LED
0
T, LED
//0
MULTIPLE MOUNTING METHODS SHOWN. NOTE:GREAT WHITE$LAID OUT AT 2 MODULES PER FOOT,4"ON CENTER.
(@ MOUNT THRU STEEL STRAP
MOUNTING VARIES PER WALL CONDITION. EACH MODULAR 60 POWER SUPPLY CAN RUN UP TO 22 GREAT WHITE3 MODULES.
MINIMUM OF 4 MOUNT'ING POINTS REQUIRED, LAYOUT BASED ON A 5'CAN DEPTH. A
ISCALE: 1 W=11-0� 60
FRAMING/LED LAYOUT
IREF, #
4'-0'
15/16 3'-4 1/8" 3 15/16-
COMPLIES WITH:
2007 FBC, 200S SUPP-L.
ASCE7-05
GROUND WIRE FASTENED--
--..... ..
TO ALUM. BACKING
-WHIjamB, Ze veld, PE
FL. Lic. 1, 1169
P.O. Box 8 0088
A
n
[N M ROSWELL, GA 0075-0 01
I -�
(828) 692-7681
nz)-
72 12
92 1
DISCONNECT SWITCH ON RIGHT
ISCALE: 1%"=l'-O" I SCAL
E E: 3*="-O" A
SECTION rR E F.' #
ALTERNATE GRAPHICS — DRIVE THRU PHARMACY
IPROJECT: JOB # AAPROVED BY DATE
REVISIONS
N
No. DATE: BY: DESCRIPTION REQUEST # 606q0
1418 ELMHURST RD.
ROPR. GR.:
ICO ELK GROVE VRJAGE DRAWN:
A 08/24/09 is REVISED LED LAYOUT JBE
ILLINOIS 80007
09/29/09 is REVISED PLASTIC TO #2447 n DATE: 03/12/09
IdentIty Solutions
SALES MGR.:
SCALE: A
DRAWINGS ARE THE EXCLUSIVE PROPERTY OF ICON IDEKITTY SOLUTIONS INC.,ANY UNAUTHORIZED USE OR DUPLICATION IS NOT PER MITrE S NOTED
THIS DESIGN IS INTENDED FOR USE BY THE ICON COMPANIES AND THEIR APPROVED VENDORS IN FABRICATION,ASSEMBLY AND INSTALLATION.
]GO ENGINEERING DRAWING
N MAIL 0 CLAIM TO ANY STRUCTURAL.ELECTRICAL,NICHAIRCAL OR FOUNDATION ENGINEERING IF THIS DESIGN IS USED OUTSIDE OF TITLE: (FILE; SHEET #
THE ICON ECSeNPAHIES AND THE APPROVED VENDORS. 1 '—6 X 4'-0" ILLUM. DIRECTIONAL SIGN WAL S2 of 3
3263E
ca
A
mo
-n NJ
rm. b r
co
w Cl)
CD G) 0
>
co CD �i
5
0) C5
(D it
C*
C*
*4 CO
'�j
vi
X
V1
* * r ,, #D' -� C,
N4�11
IN
ROO
Pit
L'I 'Ib
qt
le
N.1
4M
If
Gr
Typ.
COMPLIES WITH:
4'-4 1/2'
2007 FBC, 2009 SUPP-L.
7
AS
S-2 5/8' EQ_
C76) 06
------(40 7 14
025
William B. Zeeveld, PE
FL. Lic. # 61169
P.O. Box 800088
C12) 0-090
ROSWELL, GA 30075-0001
(828) 692-7681
e0l 50,
W1
..............
SCALE: LE"
1 ScA
BASE PLATE DETAIL DETAIL 2
............................
----040
----040 1/4" xvill
J
"_M�o
0 0
n2l
i 1/4'
14- 0
SCALE. HALF
4 DETAIL
FACE DETAIL MATCH PLATE DETAII 3
REF�
..........
-S
PROJECT: JOB # APPROVED BY DATE
REVISIONS
EQUES- ENCR. M
711N
No, DATE: BY: DESCRIPTION �77 3,
1418 ELMHURST RD, REQUEST# 80601.)
'(UPf, OPR. MGR.:
DRAWN: E 1PB //R N
ELK GROVE VILLAGE
ILLINOIS 60007
4t
con DATE: 01 /27 '1 PR012. MGR.:
Identity Solutions W-0- X 14'-4 1/2" DAF 1:LLUM, MONUMENT ATLANP11C BEACH, rL
WIIH READERBOARD LOCATION #:13028 S TED SAI El MG1.:
SCALE:
Dumnits'SARETHE"CLUINVE PROPERTY OF ICON IDEffrffYSOLRMMIMC.,MYVNAUTWORIZEDUSt OR DUPLICATION IS NOT PER*ffrE[L 'AS NO
THIS USSION 13 INTENDED FOR USE BY THE ICON COMPANIES AND TNEIR APPROVED VENDORS IN FABRICATION,ASSEMBLY AN INSTAUATION. ENGINEERING DRAWING D/F I C M �FILE: WAL3712A S,2 of 4
[CON MAKES NO CIAIM TO ANY STRUCTURAL ELECTRICAL,INECRANICAL 00 FOUNDATION ENGINEERING IF THIS DESIGN 6 USED OUTSIDE OF TITLE: 8' -0" x 14'-4 1 /2" ri LLUM. M NU E j SHF-Y1 #
TKE ICON COMPANIES AND THE APPOOVED VIINDORS.
r
...................
No, OTY. DESCRIPTION SPEC.
I AS REO'D EXTRUDED CLEAR ACRYUG HINGE, UV STABLIZED (OUIWAIER PLAS) F2000--Cl,
..................._1................
2 AS REQ'D UV LFNS TRACK COVER
3 AS REO*D VH8 TAPE, DOUBLE FACED
-—------------- .....................
4 2 PER LENS lo- 32 HEX SOCKET BUTTON HEAD SCREW W/CAPTIVE WASHER 116070
_�ii"LENS 10-32 PRESS-FIT INSERT FOR PLAS'71"C'S','3/8" LG
6 3 PER LENS:#3 X -5/8" S,S. PAN HEAD SM SCREEW
03/16" HOLE IN LENS
01/4" HOLE IN TRACK,
INSTRUCTIONS FOR NSTALLING COVER & HINGE
Measure tracks and lenses to trinn and align as needed.
INSERT ITEM#
2. Clean and dry tracks.
3. Align lower edge of lens with lower edge of glue on lower track
FASTEN VATH ITEmi
and with end of tracks keeping c1l edges straight.
4. Remove masking from VHB double faced tape and adhcre to I�Op
L
_SIGN FACE
track.
5. Drill Ya" holes into plastic hinge and too track 2" frorn each end and
in center in double faced tape area. Ins"all pan head Phillips sheet
READERBOARD TRACK
metal screws into drilled holes.
6. Drill Y16" holes 14" from each end at bottom of lens in line with
thick glued area of lower track. Drill yj." holes into lower track in Iine
with �46" holes in lens.
Place brass nuf into Y4" hole slotted end fits� flush with track
surface.
INTO 01/8" HOLE IN HiNGE
8. Place hex socket screw into lens hole and back up by screwing
captive washer on from behind lens.
______(3)BETWEEN HINGE AND TRA
9. Wipe clean and secure lens in place with allen wrench.
10. Continue process with additional lenses lecv:ng Y8" gap between
lenses in the same line.
COMPLIES WITH:
2007 FBC, 2009 SUPPL. _0 0
ASCE7-05
Z kq: A.
cc
William B. Zeeveld PE CID 0 V=
FL. Ljd.�# 61169 02
P.O. Box 600088
ROSWELL, GA 30075-0001
(828) 692-7681
_qALE: N.T.S.
INSTALLATION INSTRUCTIONS
-44 r
ROjECT: JOQ_ # APPROVED BY DAFE
REVISIONS
ENGR. MGR.!T�
No. DATE: BY, DESCRIPTION REQUEST# 8 0 6 0 3
0 1416 ELMHURST RD.
ELK GROVE VILLAGE DRAWN:
EB /RN OPR, MGR.,
ILLINOIS 60007 /
MGR,:
icon . PAF
T ANTIC BEACH, FIL DATE: 01 12711 0 P"Od
Identity Solutions a'-O" X 14'--4 1/2" D/F ILLUM. MONUMENT AIL
W11TH READERBOARD LOCATION #:13'.28
SCALE: AS S MGR,:
DRAWINGS ARE THE WtUSIVE PROPERTY OF CH IDENTITY SOLUTIONS IN&.ANY UNAUTHORIZED USE ON OUPLCAMN is NOT MMIMD.j NOTED 'AE
THIS RESIGN 13 INTENOES,FOR USE NY THE ICON COMPANIES AND THEM APPROVED VENOM IN FABRICATION,ASSEMBLY AND INSTALLATION. ENGINEERING DRAWING
ICON MAKES NO CLAN TO ANY STRUCTURAL.ELECTRICAL,MECHANICAL ON FOUNDATION ENGINEERING 9 nus DESIGN IS Uses OUTSWE Of TI TLE: SHEET #
THE ICON COMPANIES AND IN APPWM VENDORS. 8 —0 x 14 —4 1 /2"" D/F LUM, MO ii�ILE: WA'L_3712A S4 of 4
..............
I-A
rx
Mo.
INS
I I
WIN
Ber
pop
will
1 112o
Md
Stu- At
'of
2-I*j I VIAA i 6p],ruk", F-4 GA Nk>)
..........
Wil
dr- ----- - - - - - - - -
MN
a,-17A I'*JAN 0 PAR
g4uil
IM Cap"Anm
'A
PAP I
I A
P-m am=aim
0
ME Lo LEAL NONNI now
HUB
-------- w *lwI I I I I lie I I ilgilil
BORROW i Hilifigglig ilil 1 .1-111
1 111111 li W ililispiligliell
pX1111111111liq MINIMUM if W i i
man F,C', OR
ol!'#Pnllpn I all
01141IM1111,11P.1m
10-p
0
RK q= W , A For P
A! U 2m9V—p4= -1 ,
11 1� I
W MON M�W'
WWI-
mg WN It -0
Ir
11L
5 1 i I i I igglilil r4
was HIM
EW Otlip
offd
4A 11
Wal's 111vij
'!I'1!�7
P4*
*QrffjtV1# rb*4VAjFAf'j P–t
A&
kff-�n�,
-----------
ALU.'JINUV EXTRUSION P EXA260004-288
1 1112" x 1 1 X 3/16" X 1 112" Al UMINUV ANGLE
2" X 2" X 3/16" ALUMINUM A N G LE
I f!- 4" Al UMINUM FXTRUSION RACEWAY w/ .0,')0" A[LIM. COVER
2" ALUMINUM EXTRUSION RACEWAY wl .050" ALUML COVER
1 .050" ALUM. SHEET, DARK BRONZE PRECOAT, FORMED FACE RETAINER i,)0_3
1,(4 D
fe,e 050" ALUV IIEET, DARK BRONZE PRECOAT, FORMED DIVIDING BAR COVER
0 050" ALUV,
RMED DIVDING MTG CIIP �00J
i4 it ft, SHEET, DARK 8RON7E PRECOAT, FO
20 2 5" X 5" X 1/4" STEEL TUBE, 2'-8 112" LG 0�l
(19
2 4" X 4- X �/16" STEEL IUBL, 5'-1 5/16" LC A5,00
1 1/2" X 1 112" X 3/16" STEEL ANGLE A-�C','
22
2 5' 1 ft, 03/8" STEEL SAG ROD 1 A��C
%
X 1" STEEL BASF
3 0 2 PLATE A36
10" X 10" X I STEEL M A I-CH PLATE
c2l ----
-52 19
463�' 2 1/2" X 2 1/2" X 1/4" STEEL GUSSET PLATE A36
(Do 'IR ", -..' ---- -.1-1 -1
3/16" THK. #7328 WHITE TRANSLUCENT ACRYLIC FA(
4 0 150 q it-
�E
AS RECI'D 3M 7725-10 WHITE VINYL (ADDRESS T.B.D.)
7�
41
4, 20 1!- ZIP--TRACK, TOP TRACK
44 -TRACK, MUTUAL TRACK
80 ft, ZIP
A
4 20 ft, ZIP-TRACK. BOTTOM TRACK
............
4; 1 UNION, U.L. AND ELECTRICAL LABEL LOCATION
AS RCO'D DARK BRONZE PAINT, SATIN FINISH
Z'
'GRAIDE" 51 45 -'q.f%. 3M #3530-53 CARDINAL
RED VINYL FILM
gk-
4
so 4 F60T12 C.W.H.0- LAMP (12 000 HR. RATED AVERA
61 2 BALLAST: ASB-2448-46-BL-TP (ADVANCE)
BALLAST: ASB-0412-12-BL--TP (ADVANCE)
NL
65 1 SAFETY SWTCH (MULBERRY #30482, SINGLE POLE, 20 AMPS)
IN BOX
67 1 WEATHER DROOP JUNCTIO
...........
69 1 POWER SUPPLY
_CONDUIT
70 AS REQ'D #10 S.S. X 3/4" FLAT HEAD SCREW
71 AS REQ'p SCR W, HEX WASHER TEK, #10 X 3/4", UNSLOTTED, ZINC FINISH
A3 2 b
72 8 03/4" SrEEL ANCHOR BOLT w/ NUTS AND WASHERS
7,3
112�-73 HEX HEAD BOLT wl NUT AND WASHERS
'd
7C AS REO'D 1/4"-20 HEX HEAD SCREW .7—NUT-AND WASHERS A'307
77 AS REO'D 3/8"-16 CARRIAGE BOLT w/ NUT AND WASHERS A 3C I
----------
AS '6- '1) #6 REBAR, 12" D.C. BOTH WAYS, FRONT AND BACK A6 I,,,
90 01 3/8" HOLE TO ACCEPT 1 1/4" DIA. ANCHOR BOLT
91 i 61 05/8" HOLE TO ACCEPT 1/2" DIA. BOLT
COMPLIES WITH:
92 1 6 01/4" DRAIN HOLE wl SHADOW MESH
- MASONRY BY OTHERS
2007 FBC, 2009 SUPPL.
66WERE�E—(S-E-EEN'-
GINJ�JR"Cj C.ALC�
ASCE7-05
-RICAL
ELECI miliam-13"Ziseveld E
NOTE:
FL. Lic. 61169
LAMPS (14) F/60/T-12 C.W.H.O. ------ USE WHITE SILICONE TO THIS SIGN IS INTENDED TO BE
AR
EA/WEIGHT THIS 2007 FLORIDA BU�LDINI INSTALLED IN ACCORDANCE WT'll THE
(2) BALLAST: ASB:-i448-4i�--BC-: SIGN TO
(ADVANCE) JCHT LEAKS REQUIREMENTS OF ARTICLE 600 OF
BEAR Ill CODE P.O. Bo- 8000-18
IS MARK Irl
(1) BALLAST: ASB-0412--12-BL-TP SIGN SQUARE FOOTAGE: SIGN INTERIOR E NAT10NAL ELECTRICAL COD
AMPS 11�86 D/OR OTHER APPLICABLE LOG
73.1 sq. ft. (CABINET) Va%nmsm PAINTED GLOSS TO BE A'l OF THIS INCLUDES PROPER E AL
V-A, 120 VOLTS WATTS 77q ESTIMATED SIGN WEIGHT- WIND LOAD 140 MPH TOLERANCE:± 1/16" ON ENAMEL WHITE FOR CO OU S.
GR NDING AND BONDING OF THE
DESIGN LOADS: ROSWELL, GA 3C075-0001
ELECMIC Boom EXPOSURE C MAXIMUM REFLECTIVI TY
ALL DIMENSIONS
(CABINET) SI GIN.
(828) 692-7681
ELEVATION VIEW AREA/ WEIGHI NOTES SCALE: -51/8"-!'
F,
ri-IROJECT:
REVISIONS JOB # APPROVED BY DATE
No, DA TIE: ENGR. MGW.-
REQUEST# 80603 10
11 Y� DESCRIPTION
1418 ELMHURST RD.
�j 0
* MGR.
ELK GROVE VILLAGE DRAWN: EB 'RN
ILLINOIS 60007
icon . PROJ MGR
D A TF,
,,-)'.
Identity Sofutions 8'-0" X 14'-4 112" D/F ILEUM. MONuMfNI ATLANTIC ;3LACh. FL
WITH READERBOARD LOCATION #i 13028 SALES MGR.
con .
Una. TED
DRAWINGS ARE THE EXCLUSIVE PROPERTY OF[CON IDENTIFY SOLUTIONSINC.,ANY UNAMORIZE11 USE OR OUPLICATIONISNOTPERNITTE SCALE
: AS NO
TMINISIGNISINTIENCEIRMUSE21TIRE ICON COMPANIES AIM THEIR APPROVED VENDORS IN FABRICATION,ASSEMBLY AND INSTAI.
ICON MAKES 90 CUM TO ANY STRUCTURAL.EMTRICAL.NECKANICAL OR FOUNDAnes ENGINEERING IF THIS DESIGN I$ non. ENGINEERING DRAWING
UsionTM(IF TITLE:
FILE: SHEET S
THE COX COMPANIES AND THE APPROWIVENIML 8' --0 x 14'-4 1 /z_ D/F ILLUM. VIONUMENI WAL3712A I f
A
'41
4 1
D
7
C
6,
40
(2�)
d
�j
NOTE:
N !S TO UE AIRED PER. DIAGRAM
ON FROVIDF A MINIMUM OF 30" OF
UA`LAST. USE 14 GAGE AWM, "OlUD WIRE TC ALLOW �OR
STYLE 1452, BALLAS I
1000 VOLTS IF �--M�O-VAL WH.'EN SER\mcING.
EYTENSIONS ARE REOUIRED.
ELFCTRICAL LFADS TO BE 12 GAGE
NITW WIRE. SIGN MUST BE GROUNDED 4r
1
W1-H
14 CAGE GREEN IR E,
*z
F R A V I N IS L A M P I N G-
list
REIF. #
.32
oj
112'
4-3 314'
COMPLIES ITH:
5 1/'r .......... 2007 FBC 2009 SUPP'(
5'- 1/4'
ASCE7-05
William Zeevel E/
0]
"S-
FL Li # 61169
P.
1 2'3� 3 ox 800088
ROSWE.��L, GA 30075-0001
(828) 692-7681
LSK,
I H FSCA—LE—�,,"=1�-61-
ri�U C
F-PROjECT:
N c
D A T E By, JOB # APPRrVED �i) r-;ArE
DF r'R!PTI�N
1418 ELMHURST RD. ENGR vICR—j:;::1'
P,[Q(EST#
8060
ELK GROVE VILLAGE rL3,1 ---------
ILLINOIS 60007 DRAWN: OPR. MGR-
EB/RN
icon
Identity Solutions DATE-
Afi HAC 1. 01 /27 0
'.ORUE�D USE ON DUPLICATION IS Nor PER
FAWINGS ARE THE EXCLUSIVE PROPERTY OF ICON IDENTITY soLunams INC.,ANY MAIL
S A
41 DESIGN IS INTENDED FOR USE BY THE ICON CompARIFS AND FHEIR APPROVED VENDORS IN �10TH OAI�-
:ONMAKES 11111CATIO1.01111.1111AI.I.S 1""T'.'N. U28
III ......... 1) 1. IOCATI�YN #:1,30 N 0 sALIS mGR...
0 CLAIM TO ANY STRUCTURAL,ELECTRICAL,MECHANICAL OR FOUNDATION C IF THIS DESION Is USED Urs[Of OF SCAL E
ENGINEERING DRAWING A
CON COMPANIES ANDTHE APPROVED VENOMS. N. --J--M L t
"I (I'll E:
�U Nvi. v(Y A 7 . #
W -A