Permit 1979 Beach Avenue CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD ATLANTIC BEACH FL 32233 `4 INSPECTION PHONE LINE 247-5826 Wilt � Application Number . . . . . 05-00030656 Date 6/29/05 Property Address . . . . . . 1879 BEACH AVE Tenant nbr, name . . . REPLACE SLIDING GLASS DR Application description . . . RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 1200 Owner Contractor ------------------------ ------------------------ PETRONI, GERARD LOWE ' S HOME CENTERS INC 1879 BEACH AVENUE f 12945 ATLANTIC BLVD ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32225 (904) 486-4701 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 90 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 1200 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 90 . 00 90 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 90 . 00 90 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING OFFICIAL CITY OF ATLANTIC BEACH cc. BUILDING / ZONING DEPARTMENT �L- �Fflg r 800 Seminole Road S Atlantic Beach,Florida 32233 F3 �, (904)247-5800 (904)247-5845 Fax www.coab.us PLAN REVIEW COMMENTS Permit Application # 65—�fyy`J(.P Property Address: ! (J�Ql IVV�l�(V Applicant: Project: —Tn / m / f This permit application has been: ZApproved Reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed By: Date: 2�y Date Contractor Notified: i 'L1r CITY OF ATLANTIC BEACH WINDOWS, SKYLIGHTS, GARAGE DOORS,HURRICANE SHUTTERS VS2i �I Dat?-7 U � C- Job Address- c:: Owner: �� / Addres E7 Phone: - - L 6 P 1- Legal Description- Block Number: Lot Number: Zoning District: (�/ Contractor: ,/ Uj IE-s ate License Number: �� J��' _l ` Address: � -� �. Phone: �y fc7J/�f�l0 7 Id"? City: '�'l f �.t� State: .M Zip: �-,WS Fix: �4 V1716) Describ proposed use and work to be d e: l �•¢�� �fl Present use of land or building(s):�Ler / /4 Valuation of proposed construction:—/ ,�?66C�- Is approval of Homeowner's Association or other private entity required? If yes,please submit with this application. Required Building Data: Mean Roof Height (ft) Building Width (ft) Building Length (ft) Roof Slope Window Height (ft) Window Width (ft) Window Elevation from Grade (ft) Measurement from corner of building to window (ft) Number of windows being installed Mean Roof Height 800 Seminole Road •Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800 - Fax: (904)247-5845 - http://www.ei.atlantic-beach.fl.us Page 1 Revised 1/27/03 r Procedure: In order to expedite issuance of permits provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. In addition to the building data,the following information is required: 1. Manufacturer's Test Report with Uniform Structural Load(psf) 2. Installation Procedures 3. Window Description/Type 4. Garage Door Description/Type 5. Skylights Description/Type 6. Hurricane Shutter Description/Type 7. Elevation View of Window Locations I hereby certify that inform' ded wit this on is correct. �--- r-- 2����. cis Sig a of Owner. Date: I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with,whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions,of any federal,state or local rules,regulations,ordinances,or laws in any manner,including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true an&norrect and that the plans and pporting data have been or shall be provided as required. - t Signature of Contractor: Date: Address and contact information of person to receive all correspondence regarding this application(please print). C _ Name: �( T*AA' 1�1..- C Mailing Address: ,/ 7j L L-Z S Telephone: PZ� 7� Fax: E-Mail: AS TO OWNER: Sworn to and subscribed before me this day of ,20O 5 . State of Florida,County of Duval JEANNE M.SHAW Notary's Signature: &;= My COMMISSION#DD 435986 EXPIRES:May 31,2009 personally known BondedThruNo rYPublicUrdenrrAers Produced identification Type of identification produced 'F L- AS TO CONTRACTOR- Sworn to and subscribed before me this T` 1 day of ,200 S State of Florida,County of Duval Notary's Signatur4 P•. JENNIFER SCHLUETER in...Yec�•. rt. ' MY COMMISSiom#LC 121301 Personally known ExPiRE.:;May 27,zoos produced identification ••;F'•••'d"� BondedThruNu[an�PublicUnoenvriters Type of identification produced 800 Seminole Road Atlantic Beach,Florida 32233-5445 Phone: (904) 247-5800 Fax: (904) 247-5845 http://www.ci.atlantic-beach.fl.us Page 2 Revised 1/27/03 t ppppp- LoWEnS L, Hc)ate improvement Warehouse InWWng Herne Imprmo not 8529 South Park Circle, Suite 430 Orlando,Florida 32819 Bus. 407/370-2872 Fax: 407/352-6309 Limited Power of Attorney Date: 7 To: Building Department From: Peter Anthony Cafaro III I hereby name and appoint Maria O'Reilly, of Lowe's Home Centers, Inc. to be my lawful attorney in fact to act for me to re iste��r.my license and apply to � fora �7--�2� ��� permit for work to be performed at a loc ion described as: (Address of Job) 8 7 (Owner of Property) And to sign my name and do all things necessary to this appointment. Thank you for your assistance. Sincerely, 6 Peter Anthony Cafaro III Area Installed Sales Manager Primary State Qualifier CGC 1508417 ,4 r t WCOMI�lISSIOM DD119S3 EXPIRES �X da of 200k =4-.. Sworn to and subscribed before me this y pF; - sown�nanrao�YF1Z200anrMiNc No.public �__ My commission expires 3a ADDRESS BUILDING PERMIT NUMBER INSPECTIONS: FOOTING UNDER SLAB PLUMBING SLAB FRAMING COVER-UP 1- 30 - 9y INSULATION -// `? `?L FINAL BUILDINg CERTIFICATE CDr ELECTRICAL PERMIT # INSPECTIONS ROUGH FINAL MECHANICAL PERMIT # PLUMVTN,, PERMIT # NOTES _ t E NOTICE OF PRODUCT CER'ITI'ICATION V lCnmpany: Southern MINworkCempany CCr`lWCMinNo.: 1M11i01OSM7 10435 Okanella Street Certfieartion Date: 1W15r2M + grndu,ct: ljtberCiassic#5raooth Star Glazed Fibereass Door I nswing{outswing►rel and w/o Sidditu SpeeffieaffoQs Tested Ta. ASTh11330i1`E331MAS2,02 s *eaNatiae of lProduet Cerli$catlrn"1s ealy vs>Id 33 the NOMI CerBiicatEvn Label lies been applied.to the product as described wftlria ibis drscrr=jst The rertlil+rativat 1,obd rrpresenta product conformity to the■ppiitabk speedleatlun and that all certi#fcadorr criteria has been&Mhfled. Th€s product has bees approved[or fhtkgvftMa -� t+tAAlI's Certified!'rvtkctt 1Liaiing at gw Namieel til atiaac�s/RA Wa Cgrdfication Program is aceredW by The Ataaieant Na anal Standards Imslitate(AY484 d �7esigtt Mlsalle Teat Repert Number o°'o �' ConHgrsca#isu or or Preserve im"rt & 011sw 0-ow-we P 1M1 Raked ComntMh tf�' +i.l ve_.d 3`0 6%R3% -+471-47 No NCIT-214-1940-1.2.3.41"TI'f`'-256F Siir 1e � x Xfl +Glazed 3''�'$„ +47}-47 No ltifC17,.210-1940-1.2.3.40][ F-25SF Q single XX � T/s Glued [' $" +4ib+-40 No NNCTL 210-1940-1.2,3.4MV-256F DoubleSftdwd Ahwdom Aikagd xx ole Glazed 6'0j"x6'S" -{40140 N4 AICTL 2IQ-194{3-1.2.3,4�P-255fi Double Standard Altuak am Astra i + Xx VS Glazed 6'4"x 6'S" 4471-47 No Double --,--Cwfti Aluminum Aswgaj Xx O/S GlaU(r R ON E 1)6'0"x-6'8" +471-47 No 14-1940-12.3AfM 25SF/ 13ouaie CITY OF ATLAM C BEACH 'Alqm-m=AxragM ':. OXt7ft3=0 l/S '4"x+S'$" +40/-40 No ETC 1-i i4(k8.011,215 i/'i'TF-256F 5i kw/Sidclites Glaze OX£1tQX1110 CWS Gl "x 0'8" 40�'�t4 Na I;7'C-Q 1006.01L,2 L5 Ln-rF-2558 F-- Sin le 9 iswlites Glazed Sidelites oxxo TIS Doers '4"x6'8" -+4{imo No HT"l- SAIL-215VITF-2:56F bis�rlSirieliies S ,Atumim n Astragal 4xxo Q/S Glued Do= 8'4"x Wk x-44 No STC-01741-11009,OIL-21S1CI'1F-255F it w/Sidelites Glazed Sidolitas Stands Atmrnirmm Astra o C;XXD VS GhLwd Dom 8'4"x6'8" +471-47 No EITC-01-T4s-11048.WL-215IfM.256F � Double w/Sideli#es Glazed Si6clites Coastal Mumi A al CD OXX() 01S GlazedDmm B°4"x 6'S" +430-47 No EIr,}1-741-11008.011 15tnTF-355F Doublew/Sidelit€a Glazed SiMite:s C As ai � Nat1t►nal Acrareelkatilm&Management hwtitat+e,bmJ4655-104 Mentledia A�venuefWi�a tit 31N � IL 'Tel-7571,%M1/`ax'157.258.8815 Cxi NA.MI AITTHORMED SIGNATURE: NOTICE OF PRODUCT CERTIRICATION40 pnr Sautlrera A►lillwork company Certification No.: NIIM508 104111 Okenella Street Certification Date: 10/1512093 luta er4 lit !I%r TA �`t.:�..._._._ ..-... ..-......__ Product: FiberClasslwrlSmooth Star Opaque Mbeglass Do"Inswingioutswing ter/and w/o Sideiites `'- Specifleadens Tested To: ASTM B33OM31MAS202 Ttte"Notice of Product Certifbeatioo"is nalg valid if the NAW CertlSesriioa I.elod has been applied to ilia product as descried srftbia this deeameot. The certiiieatlmi+ o speciftattan and that a8 cer�eation erit�a bas been.satisfied. Ibis product his been a"roved far Sstbag wiEhla label reisresecsts product caafermif to the applicable e r4AA�II's Certified I'Yoduet f i#iag at www Kamicertf1'Scatiourcom. MAY111 Certi�eafion Program is accredited The Aaserican National Standards Institute(ANSI), m � Co Irrbwiog G1ar�ed design tt a Test Rego rt Number � m j Cafguratiea at crr i4Tssdumin Plus"" Impact & w r ; Qu(sw ue S1ze 1!�istiY Rated Comancats Liss 1'0?'x 6'8" -F671-67 NO ETCH 1-741-10702.M-2446ITTF'252F z single x x O/S Opaque 3'(Y x6'S" +671-67 go EW-01-741-IG702.WL-2@96rfTF25lF w Sin a xx 3/S Onaq_ue 6'0"x 61" -+401-40 No ETC-01-741-14702,0 L-2096FrTF252T Double Standard Aluminum F' xx 019 Opaque 6'0"x6'9" +40f-M NO SLC-0l-741-10702_0fL-209&rTF2.SIF Double Standard Aluminum xx IIS [)Vague 610"x 6'8" +551-55 No H t'C: Ij 741-I1tDEH AWL-2.1311'1-firzVt o ]kutble Coastal Akwduum Astmgal xx O1S Opaque 6'0"x 6*8" +551-55 No ETC-LD1-741-110MML-215lfrM5IF Duvbk Ccras:ai fid=1inu:r M"sw MOM= 1l5 Opaque Door 5'4"x 6V +40/40 No ETC-01-741-11008.01L-21 SIRTF-252F z SinwlSidditas dazed Sidel les a U-' 0XO/0X/X0 Ol5 Opaque Door 5'4!'x 6'8" -t-401-40 No ETC-01-741-11008.M-2151f1TF-251F x silde.wlSkwiles CAmed Sidelites CD OXXO I/S Opaque 1?oom 8'4"x 6'8" +40140 No EI'C-01-741-11008.0/L-21511T£.F-252F a ! Double wISidelites Glazed Siidelites Standard Ahm2inutn Astragal o OXX0 M Opaque Doom 8'4"x 6'8" +40/40 No ETC-01-74141008.0&-2L5bTU-251F i Dour wM iderd" Glazed Si deliteg Standard Ahaninum Asha91 N 0 OXX0 us Opaque Doors S'4"x 6'9" +551-55 No ETC-01-741-11008.4iL-2151/TTF-252F :2-1 Double w/Siddites Gleed Side5tes Coastal A6unimim As al 0 4XXQ t]1S Gpaqu+e Doors 8'4"x P8" +-551-55 No HTC-01-741-11 -2151fI"FF 251F LO Doalrlew/S€delites GlazedSidelites on AxwWal � National Amreditation&Management Institute,lnc 4455-104 Mont *Avenw1W 23188 Tel-75'.25$,SS481pax-7S�,Z5ft.$$15 �' z ti NAM AUTHOREUD SIGNATURE: NOTICE OF PRODUCT CEIITIFICA.TION CamWy: Sowthern iklplwotrk Company Certification No.: N1095509 WA29 in><oaAffa x4 Cer(Weation Date: 1-D11512003 ro Ffoduck Ymmium Series Wood E W Opaque Steel Door Inswine0stswiag w/And w1a Sidelltes Specifications Tested To: ASTM E33 E MIffA826V2021283 -0O M Tfie"Melee of Product Certdieatiom"is only valid if the NAN I Ct IRkadw Labe!has been app&d to the product as described witlrin ibis dommeut. The aerNficatton C:) label reprewats product confor *to the applicable speci6tateon and that at certificadan edteria has been aaiiedied. This pmduet has been=pprorted for listing wItWo CM lair is Certified Product Luling at www-KIMIcerlif 1cstiou.com. WAitdl's Cerdfirstien Program is accredited by Thor Amerinm Nadeau]Slwi dwds Inati#ate(ANSI) w Insuring G S=d Desigs iVlhwe Test Report Kwnber o �,, ; C figmratiLan or or Mauiuram Pressure IN41ect & en r- QutsWa SIM PadNl Rated comm a as x ;IS Crp- = 3,r x S'n" +4{I-45 VeR WCTI.,210-2030-11PSI-9205F C5 Sin le x QIS Qpague 3'0"x S'fV' +451-45 Yes NC"TL-210-2030-1/PSI-82W Single x xxus t WwI 63tf"x 8'0" +4&40 Yes WCTL-210-1917-1fFSI-8205F fMuble Standard Alusnirom Astragal xx O}S Opaque 5'4"x 8'a 44Of4O Yes NC L-210-1917-I1PSI 8203F Dasihle Standard Aluminum Astraol x xx YS Opaque 6'0"x8'fl" +451-45 Yes NG"Ti:21Q-1917-11Y51-820F 3 Doulale ConeW Aluminum As l xx 015 0paquC 6'0"x 8V' +451-45 Yes NCS L-210 1917 liPSI-9205F Double Laastal Alurnirum.AL - DI£010XtX0 IIS Opaque Door 5'4I+"x 8'0" +451-45 Door-Yes C TL-2l0-2030-IlPSI-87A5P Sin wlsiddiks GlazedSideiites sidelifesrNo LLJ OX010=0 ON Opaque Door 5'4"x 8'4" +45145 Doac Yea NCn-214-20304►PSI-8205F i Sin ewlsidelites GlazedSidelites Sideliles-No CD oxxo its Opaque Doors 8'4"x 810" +401-40 Doors-Yes NCTIl-210-1917-1/M-8205P Double wZdclkes Glazed siddites Sidelites-Ne Standud Alumir= ,n dxxo OIs Opaque Doors 8'4"x 8'0" +40140 Doors-Yes NCTL.-210-1917-11PSI-8205F o Double edfSiddites GW"Sidelites Sidelites N4 &wdard Aluvmpm Asir 1 o OHffid I15 Opaque Doors 8'4"x 8'0" +451-45 Doon-Yes NCTL.-210-1917-1IPSI-8245F z Double Glared Siddites Si&fkes-No Coasad Al ainum Asir OCNS Opaque Doors 8'4"x 8'17" T--T 11-45 Doors-Yea NCTL.-210-14 IJPSI-8245IK o Doubk Glazed SWelites Sidelites-Ido Astra l � National Aecredita#ion&M=ftement histiltlte}NCJ4655-104 Monticello Avec 231N N- Tel-757.758.88#}8JF`ag-'f57.2S8.8$gS ...., NAM A.UTHO1Et12ZD SIGNATURE- 4D NOTICE OF PRODUCT CERTIFICATION Company; Southerse MillwarkCejupsny Cer#i&atlen Na.-. N1095514 m tad'Xa!'li w4lla Cfrnnt CertNlicatim Date: 14115IM03 N H�_yy••�� ��rraN1//ii _1y _1_Y��y OUSEQU, TX ) 'VTI /J X14 N6i+tl1-ai%MfM. ��a�.. �vr.. IP P adat t: Preminm Series Wood Edge Glazed Steel Boar InswinglO utswing wl and w16 Sidelites Specifications Tested To: ASTM E33O)E331MAS212 Tiije'Won=of"Pmduct Certifiewdon'is oW ralid fe the NAM Cextillc■tiaa Label has been applied to the prodW as described MtNa IkU dotimeat. the ceracsdas � o I*el represests product canformity to the appbmble apedfication and that all certftatten criteria has bees sattafled. This pradmt bas been,approved for listing within � 6r' NAMPs Cer fled Product Usft at mrwN*M certitieaAhm.cogx. NAML's Ceriii3catiate Pregrsnu is acered#ed by The Awertem National Standards lasfltufe(ANSI). N m i CO i lseswig Glazed Design MhAle Test Dort Number w I CosEguration of or 14)TaiINVa n Pressure Im"d 4& r i Oukvr1a Opagwe Sine l?os Rated C4makeofs uS Glazrd 3'0'":18'0" +5f 4� ue .-Gln-2nWIA'SI-t12041i z Sin e d x Ots Gta=d 3,0"x 8'0" +450-45 No NCTL-210-2430-1fPSi-8204F cs single Tic Gl 6'W V 9,rr +4[31-4[1 No NClT,-2141917-11PSI-8204F Double SURdardAlmimmAstrapt i xx OiS Glazed 45,(r x 8,0" +44/-44 No I CT.-210-1917-11 I-8204F Double St mdard Ahuninum Astra al ( xx US Cdazed 6'17'x S'0" +451-45 NO NCTI..-210-1917-11PSI-82W CD Double Coastal.Ahmiinu m AsqMl XX` U1S Glazed 6'0"x B'ty' +451-45 leo NCTL.210-1917-UM-8204F --a Double Coastal AhniumAsqaEN j OXOIOMAO I/S Glazed Door 514"x 8'[P' +451-45 NO NCTT.-210-2430-UPSI-9204F i Sin le wMiddites Glared Siders x OxO/U O 018 Glazed Mor 5'4"x 8'(r -+-451-45 No NCTL-210-2030-IiPSi-S204F � I Single wlSiddites Glazed Sitlelites CD OXXD US Glazed Doors 8'4"x 8'0" +401-40 No NCTL-2141917-11PSI4=4F rn Doable wtSidelites Glazed Sidelitm Sdamdard Altrneiunm Agpqpj O OXXb UIS Glazed Doors 8'4°'x 8'(1" 4.40/44) No I+IL'l~l.210-1417-14IM-8204F o Double wfSidelites Glazed Sidetites Standard Alutnkum Astra o 4XX0 US Glazed Mon 6'4"x 8'(1~' +451-45 NO NCTL.-210-1917-1/M41204F z Double wfSidelites, Glaaad Sidelites Coasts!Aluminum Admg9l i3XXt7 U15 Gland Doors 8'4"a 8' +45/-4,5Foo Ni✓TE.-210491 3- 8I-iiZQ4F C=) Double wiSiddites Gazed Sideliixs Astra � CZ), National Aeeredita A+11on& Management lnstttnte,IneJ4653-164 Montieclle Avenuetwi A 3188 � �!- Tel-757.258ANffax-757.?.2815 c� NAAH AUTH[]RIZ1&D SIGNATURE: NOTICE OF PRODUCT CERTIFICATION CO Company: Southern 11+IillworkCompaAY CertificAtion No.: IN1005511y G1. InAIC �nKana Qhvan# Cats cai �n flats 1@f1V290� 4 13 b Product: Prewl"m Series wood Edge Glued Steel Door Inswing/Citrtswing wl and w1b Sldelitm Specifiettllaw Tested To: ASTM E3301E331/T'AS2$2 4 -rue"Ala e,of Product Cerdfontiau"is only Yid if the NAN I CertWIcatlen babel has been*Wfied to the preduat as dewrOmd within this 4acmuwnt The cex-d&ati n o 1g6e1 repfxsents product coufarn ty m the a"Ilcable spedfkati n snd that W cars ficatku cr �has been safistied.. This prodskt hots hem approved for Iistingwithin � NA ,,s Cer iBied Product Listing at esu i+famicer#iffcat3oz.eoa2. M414Ps CertiBcatkn Pregrrm is aeeredit+ed by TheA.tue9ricaa National Slaniards lasiltute(ANS4 cn ' as I�rswving Glaaeti Design WhWle Test Repast Number � Cr, Cuafiguratiun Qr or MAsirsurn Pressure lmpact s N Outswisk Opg4ve Sive pelffies hated Commients GIS ?'0"t rs'8" 4471-47 No ETC-41-741-11004_01CPSi-MV C5 S' e X US Glazed 3'0"x 6'S" -U471-47 No ETC-01-741-11004.WCPSI-203Ia sings z FT, i-40E ?C-11_741_3101C1- 3F gG Doable Standard Aluminum As al X Oi5 Glazed 6'D"x 6'8" 4i114#1 N4 EM-01-741-11004.BACPSI 203F %cu'vic. Standard Alumbnan As4aaal a XX l<!S Glazed OF'x 6'$" +471-47 No ETC-01-741-110U+i.O(CPSI-203P ' Double Caritas ALmmi n Ashagal -, DlL ram Wtt" +471-47 1 ETiC-01-741-1101)4.0/CPSI-203F Double Coastal Alumiawn Astapl OxOIQxfxO US Glamd Boor 514"x 61" +47147 No NCTL-210-2030-lfCPsi-203F w siiwe Wisiddites Glazed SiMites ems- OXOIOXIXO O?S Glazed Dow 5'4"x 61" +17147 No NCTL-210-2030-IICPSI 203F C> Single 3vfsidelit m Glazed SideMes OAC 1}S GIazedDoors $'4"x6'8" +401-40 No NCTL-210-2030-VCPSI-703F j Bauble wAi+delites Glazed Sidelites Standard Aluminum Astra 1 o OXX0 OIS GlawdDoors 8'4"x 6'8" -+40140 No NCTL-210-2030-1/Ml-203F R, Doubts wtSideffites -laza d Sider Standard Ahmkt m Asualpi C3 OXX0 115 Glued Doan 8'4"x6'8" +471-47 No NCCL-210-2030-1/CPSI-203F CD Double w/Sidelibn Glawd Welifes Coastal Aluminum As x~ OXX0 Ofs Glazed Doors 8'4"x 6'8" +471-47 No NCTL-2I -2.030-11CPSI-203F LO Double w)Welites Glazed Sidelltes Coastal AI ins►Aqtpgal S cU Nadottal Accreditation.&Mauagement Iastiitate,Ine.14455-104 Mooficelle Avenue,/Wilti i 23188 c Telw75�.258. 110ax»?57.258. 15 i NAI4ti AQT°HORiil;Ell SIGNkTURE: 'i NOTICE OF PRODUCT CERTIFICATION - Cumpaur Soutleem mmWork Company CertificationN06: i1TItFOS5i2 m 110435 OkaneRa Street Ce3rtitkation Date: 10/15120113 '-• L..++e.f�+- ' 'Y '73J6A3 C'vrisnq nw /twin. 1'113!iifiilT- Mduct: Premium Series Wood Edge Opaque Steel Door Inswing/Ontswing w/and w!a Sldelites `••' SpectReatioas Tested To: ASIV E330JE331MAS20If2021203 The"Netice of I'm dad Cer-dricatton"is only vaild Wtine NAW Cer ieadon Label has been afflied to ti:e predict xs described whhia this doeumeat. The eertiftafins C\., babel represents pre&xt anforatty to the applicable speeftatlox aid Ibst all awtiiicafien crtterla has been soUrad. This product has been appm ed for Us t g withk Cn N'AMPs CertMed Product Doting at www-NamloertMe ation.cam. NAMI's Certiticatisox PrgVam is accredited by'ii k Amerkax Nadonat Standards Institute{ANSI) N cIi4wiioYg G lazed Dedgn blisde Tem Rcpart Kanter a co CD Cation or or b1+TvdR spm Presmre Impact & F. m Oq�stivinOpRque, size Petwell .Rated Cowmeah g I/S. Opaque 1'@-x 6W +75f-75 Yes ETG4I-741-10639.OIPSI-202FA,-2150 o Sio 1e z X flls Opaque 3'0"x 6'8" +75175 Yes ETC-01-741-10639.(1 l-202F/L-2150 `L single vs Opaque 6'0"x 6'8" +401-40 Yes ETC-01-7 41-10639.01PS1-202M,-2150 Double I S'taadar€i Alumffim Astra XX OfS Opaque 6!(rx 6'$" +40140 Yes ETC-01-141-10539.0/PSI-202F1f.21541 Double Standard Alam akum Astra ua Mpaqut$ a xo`o -rQx-Qj =qA Eii,-#a -ti-.Lto659.wrSt-1912-vL-Attu Double Coastal Aluminum Astragal XX OISr Opaque 66,x6'8" +65"s Yes ETC-tIE-741-1Qd39.01f'Si-zQ2FlL-21SO 0X0F0XIX0 11s Opaque Docw 5'4"x 668" +651-65 Door-Yeas E'TC-01-341-11006.0,OIPSI-202F/L,2149 z 5" ewlSideliteg Glazed Sidelites Sidelites Na w OX010MO, Q/S Opaque Door 5'4"x 6' " +651-65 'DOW-Yes OTC-01-741-11006.0.01PSI 2t12FIL-21h9 S' a nor/Sirielites Glxxed SidrAtes SidelAcs_No =o t oxo IIS Opaque Doors 8'4"x 6'8" 440/-SIO DoomYes ETC-0t-741-11006.0.01PSI-242,F1L-21�49 U Double:w/Sidelites Glazed Sidelttes Sidelilas-Nb Stmvi"Ahunbwm Astragal �'- OXXt3 Dig Opaque Doors 8'4"x 6'8" +4411-40 Doors-Yrs LTC-01 741-110460.CMSI-242FIL-2149 0 Double w/Sidelites Glazed Sidelites Sidelites-NIO Stw&rd Aluminum:Astragal N OXXD 11S Opagme Doors 8'4"x 6'$" +551-65 Doors-Yes ETC-01-741-11006-0.0/PSI-202F/L-2149 CD DoThle wlSidelitm Glazed Sidelitas Sidelitesr-No Coastal Aluminum Asftagaj C 4JRXO O/S Opaque Doors 8'4"x 61" +651--65 Dors-YesETC-01-741-11006_€.WSI-202F/ -2149 Double w/Sidelite& Glazed Sidelitea Sidelines-Na Coastal Alun&um As al a NatIORW Accredfitadon&bbnagement Fnstipate,Inc-f4655-104 Monticello Aver in 23158 C;' Tet-737258.8$08f>teut-757.258.$1315 a N NAME AUTRORI ED SIGNATURE: ti JUN-27-2005 MON 02:05 PM SOUTHERN MILL WORK FAX NO. 713 983 7902 F. U8 4 Y Iti s DOCR .sYSTRM, 1 THIS FIBERGLASS DDDR UNIT IS CODE APPROVEI) k' is j; i WIND ZONE: 1150 MPHOR-M N DESIGN PRESSURE (DP): +50/-61 .51 MUST BE INSTALLED PER NIANUFACTURER`S 1NSTRUCTI{(INS AND STATE BUILDING CODE REQUIREMENTS. This qualifies all Rberglass Doors in below configurations with sidelite panels up to 14"x 98". a fiOPAQUE 1/4 GLASS 1/2 GLASS 314 GLASS FULL GLASS APPROVAL/ I SAVE • BILI' I 1 • [ IRTIF7 D ES7't?+tG A RATOFM I p AmWtedura1571viskta"72$2 f-aTmvssee Rd.•Chlando,FL 3022 SideGbp Framg� rut�io a:Two(2)4-3623''rine jmnbs lord oue(1}l4sanm hila fa.Tbehwd and sill was secwvd (907)33IW7.141.Fax(407)381-7751 \ t to aha je mos aith Jour(4)8625 x 3"MOM in each entnes.Sell: SdjwsJa66n talc rap s Web SAO.Www.cdOTrh.ww Nswmg sill Ai3a 5"wM a VW 2 si&IjW seal E-Ma it tthuthxom hwd ca T%c panel n oanstruetad of fibatgim(0.09n 8aick skins.The wtedw cav4y of f ROPW waaaher:CMA-706 ws a"- side fibs Pont]is Med WA Pii foam.Ibn trap&W*n rails=PVC . 019 1i 7ste> Plastic(Omwb$PAS74)and meaaeced 1.590"wide x 128[1 hio x full kzOs Cr Auto%diff wtPVC plastic(Dm6agPAS7a(9)sand mmvw rtd 1590"wide x SMUGT[iRAt..£RWURMMCE TUT RF"RT i.1AU aii2h x fol:length.T75t trmne iassrt httd a dtar tigbt+tpe�iag 5.875`x 63".Ttie � {bent: FedW%frOdgeda,hM hood amt silt vias meeened to d is,)ambs with fm(4).6623 x 2"su plas in each owner. P.Qdaaa 29" gill:Adjastabk oak cap Wswfttigaltt A15625OLP with a Vit-2 sWafiac stat.A Saar(4) ivrwMdneo„.NcZ7#1949011 flet swcop was at w1od to the boom rral.The sidelite few was xm-W to each inmt pwA wish fom(d)#S x 2.5"drgaall saeaasa lot:tad IW,31).3,51"and 71.5'In tech Pnmhad Type"d'sas3sa: )fsa nt Pkwr&n Door wU Spedoxy Glazed BWU*Inart4 and xamya iamh nae(l)%&t 6tad and Sill toeadtd arid-xpnn.. � ltlbne'gidsX81-3hUpyiwitbiiii►tc5tityf+Lsadzt�xrt,FaotiataJPeamta H[W Glazing: 17lase)eltd?eaa�WWall",cocaistiagOftwo(2)lhtsof.125'ttsatpemdglikuh � p amu= n } .750"m spat=e whit Fetaerlot dnwta w hrass shamml.(DSOtt Glass Hitt) Itvi%ltfd9lh to G1-97-V n"PnrAlnmmtm S+in"i :Yr:::.;.... �s ll:od: L c(1;pd:.::.°v:•=�"- - .t.ia x�,^,rT:.laL76.`," tom-' and Woad Windom awl Gass Dooas". Jsm{K: turn(2)piecaa of west�mship Faadaua Q6 81)b5fl � Fasmt:CvvVwwfx: Two(2)4.5Q5"PmejanWb wdam(1)A**bw1ur.IlwIasi wdsovrasmu-cd to, Sill Gasket NlA C) d w aaanhs wide fbwM 961'4 x 2"sIwlw is cw*vixw,5p1:Ae oask cap Hardware&Loaaet3an: (1)Tiw D=Mok lacsltd 44.375"fan Cop ofpwd ismimS iM A1S6Z501.P.7ft 4ow 4tame tad sRls haat wpm nwMad haak.to.bs*WM A (1) 1 On Lsb Mk,)t wtw law lto taas WOW 45.375'fiQM wp oftxatl Iw plyaarod t;laoec mhosotlsauut"atwousyfew(24)1"x.58+'a anep7dcr3 (3)Thur 4'"hnt•burgles m+dom Srsme based 10"oe cmwrfurantop seed bottomanal eaiis in getups Of ffuav(4)k xs td r down from hand*leis 1'spaa ng batamn muk aaialgaesa toratnd 7375",38 373 sail 49375"areasutsag Sam Wp afataax. .sada 12'+6atasat btterooa$soap oFmels.Thtmda eat ianaakd ao bctib fimat:sad lsaac4 .St'at'Yat: [9`al*Vw"WIC=1 Ault into Muss a opawt... cbvfip rafiw.. Siq ZSaor wL7a Sidi I iLte(laawlag) 4724 Additioaad Deaeaiptkan: Pith binge was attacbe d ffi ruwc with fm(4)screws,oat(1)8 f 0 x 2.5"phillips =>wacsta smda strew sad 6uet(3)#54 x,759"plailiips eeamsmer asadc screws.Hingts =C Panel. Door pawl Wvxsavad 35.75"x 7$.0312".S3dolita pouts mumnW 11.75'x 79.{5312" w cw wwhtd m door pmol wide fan(f)#1 Q X 330'ptultips oeatmter emit screws. Dtar 2"=d Th=p-M-d 3s Ca--mc-ted Of s=- Im{!k Xl"}ffick skim-T_nLntrcr t,_ty..r to hills lax; Twea ty fow(241#9 x 25'loam dry vJl Aerews we=used to wm specimen toboat � tat door is 8llatai wkb PT.I fbam.brash w emboaz9dd iypee.IU top&batfams bucir.Six(6)in 6u Rime had and skin rim sill luoata!3"from each jamb las t saaTs are PYCp6as§c(13tau�tag PAS74}ttA d 1.390"Nide x 1200 be$h siakliles sad 3"£roan tach end as doer head.Six(6)ie tach%:xW to jamb k>rAetd S.i873'fieanta:fs and 54�n ccatett6eteaROr. W x fill lmmok The hialp goo is cousb tataf wath we(1)place t MM,plu de {I7nawivg PAS73(3}mameamg 1.590'wide x 12M NO and axil pause ofwo od Comment: NOaninat 2 mil pOlyrJWb=film was awd ro steer agahast stir feakags dreixg dmckw tl JaWk 71ae fol m OD {15raaviag WCA30}mesa[aiag 1.541'wtde x I.IS}'high a#tall was used in a maca"Aat did not iativasre the tact ws Ab. ,with'FLelnchsttTeisr4w& agtdvftow(1)pieeeofw0w(Dnm*. --1 WCA20)mraming 1:591'*Ads x.7974 lata w i"ut1 lcgo and one(1)swwwa n Perf armsuot To(Results co WCA60 1.591r� gtx2.364'mx20"lcxitg rii Ttas f�exglass alis is gh5od to doers•paaeL A Saar(4)fm swoop vvasii r to the E&MUW-Ik Mae-14A U2019d MOMMi door berdomma.Budaskxiti adaeau>hod"u10*50e.S'ZOfrii6prat 2.52 Aiainfiktatiaa AS77rtT2834i lbefia+ft' 30cfmftN. Mciuvred 26.875"x 36.54 wM a clear V*c> i am>s 24"s 33.0,75". ►,37 psf The tesiul apmince mtetsertzwWs Ow pwformaoct k eels specified in AAMA+J011I.S.2.97 2.1.3 1Ya w ROSiaeaett ABM IM7 NO y NO Entry 535 gpw Ftwr(A)five mioame cpolcs ccs cn r I �d3 1L�Ptcdacts tLa 1e�as/i C'IIJI-T405Y-5 'a I ftiJ O C] 2.1.43/4.4.2 Lbib=Lead 5Mwbu2d ASM 9@ al DIR 52 Pnassaw Ddumoabom TWMY raw(24]ecmdo loads 3 Thi latd2 (.odil JG.ao$2 � @ 32.0 po pwidw -.156' .374` AOG' .402" 316" O @ S2.0 pol+lagetiw .074* .A72' Q20' .096' 316' DO C3 U41 AC4q aaf=HixL lout-AUovmbkpcm.sdat'laad(O.4%ar*m)-.321' t" iao61 laid spsa ofmnitioa_Max,aAa W dfiaatiom at load(LeI73 Qf*w)_.465' -n Laoa Mid-apm of bdwdle.Mm al om*k pmu,=tat load(0.A%of spm)_-316` 2_]_4.211.4.2 Unibml4odBCvand ASPM ZOOM _ O Peraameut Db6ampRim Tdt(M exams loadsMwmmmdt 78.Opafposrti+a .071` .316' � 78.4pafNrgruiae flCA' 316• - rrl �U MidwKwaafiodps�fle.bfax.afia�vnblepom.sotet loed(4:476sfapaay=316' � Tem Dasa: App 17,2081 t— r Ta;t r"Mleckm L1ete: Apt'17,2001 Q r`d 13emwks-. Daheilnd drugs weal avaaYbla fnr bl6oraiarysegpids aad eaaapQiaan>o tLeaabt spaomaeo aR abeivae T offiampom Acopy of&$wgxtalms M t nProsawt swdm of**wt spociam VM t4 naiaod by M for a.paiod off=(4)yearn. Tba rmaYs obniaoed apply only fatbaa apacboaa tacttd. 'iris oast does aaat000stitatteoeai�ioa:afthiapsodsaY,Lia oaty8mttba abovetmt reaashs�eda o6laaacdse�g daealragpaeeedtastaaetboda and dny;odiomeaaao�di.asroarth Ilsapaa:6urm+moe (petsgr+ga6anlisfaQ}oftwabowid'ammdapad8 a*". CMAW'l eamg Labalsolics BMW=twit on >ibmaNlaap�sidedbyibeoboe iesomrac and tethe -z phyi aad chamia:d pmp bcs ad the campoaaois areae staked by fbemaoa>Bactuse r. X C*tftod Teati%LA021-*bc. O chdstdpw Bann UbMsmaw cc: FA&n (2) ft: Soathemi►tillma& (2) RaWCA hard (]) Pile (i] C f ra�aseEa EadsaaPradurts I ER71PUD WING ABORATORUS Repw 0 CTL-1MV61 a ` (_ c Sidelitt Frame Guustt tet tisk Two(2)4.5625"Fine iambs and on (t)himteadm.iJte bead MW sill buss xapred Arr3titactural7)ivlalon*725I TYsncoat�c,E 12d,+Eklmaie FI.2 rs ; ... (4M 394?�h4*Fix(4Ct7)394 7753 1 to tho Iambs R�"4)XIM'x 2"staples in each coaxer.Sill:Ad3�ble mk C Web Site;xvww.cttartR.cam cap iasvving slit k[5625QI P with a VH-2 sidedite seas C F mail:ctlarch.com elittPanal CrmtslraP'` �"� S'fQe � r�ntt:"M'!�a penal is canmstCtad of fibergEsss{Q.49Q"}thick shins.The interior caviE}•of AwOO th*Wr.CPi A 7bVW-X 4�,.. each side lite partoi is filled with Pel farm.The top&botWm rails are PVC A*M Daft .lilt 27r 3ab1 plastic(Drawing PA5 74)and measrsred 1.590"-Aide a 3.200'high x full tag&. Beth strias are PVC piaslic(Drawing PA573(S)and r msured.1.594"wide x 1200" "C7 SIRUCMMAIL PEMRMANCE TM REPORT higb x rail krqgia.The frame inaad bad a cleat lightopessing of 5.975'x 63". The � Qimu Eudora?radar%Inc head and sill wss secured to the jambs with foer(4).0625"x 2"staples in each cornier. iJ2 P Mux Sill:Ad3'usatbieusk cap inswingsilt Al56250t with a V11-2 sidelily seat A four(4) C> G fveOo pr KC"27414.•0908 fn swwp was attsobed to the bottom rail.The sidelite name was santred to eaeb insert .._.3 panel with&atr(4)4 8 x 2.5+drywall wawa located lip,303',51"and 71.5"in each Prtrdud'1''pc sad$erns: Nay*ItOJ=Wltuc Dear wfth Specialty 314 40msed O YAJ Iaset7;esti Noe" jamb.One(t)in Or-Rad and rail lobated mid-spam.. � $dsergliasa Side Utts Wah SP-WAy Ghmd I°rer4)Adan J drantcs BCD_ GltaLing: t"insuJaEed Tesnperad Glass,consisting oftwo(d)IiEes of.125"ternp:ress,d gra J3f3(63 z 81 IBswlaeg} .7501xhr space v:th interim deooWive,bmf c1m000l.(0,500101m INN) Tfo !• „$.;...^..J„y., cg"s„wfiriAueaeituswy"r'�t,Yi ,irsucri94;{,prug: iisafi: uae(c)Pima ofweathersnipErtdatsQk:8Dfi56 (PVC)and wood wadowm and Glass Dosars". larohs: Two(2i pit m of wcatbers;*15ndum QEBD650 � Silt Gasks�WA PaFramet'ompnaents: Two(2)4.5525 Ptae jattiba and lora(1)flamaLra der_1U hwd and$M use waned to *e1 tibur(4)MJ5 x 2"sapka in tKh omw, $ea€:AdivmM,mit n+e. Hardwam&Location: fl)Tito Deadhnit kY.ate l do TK,u..,.... ..f".,...t W-mag sill AI'DG25W,The door f wwet rind srk jam voem oaW b"k 4e•bac9t■rids a (J)Than I rschltoR wig Jever beadles tacatrd 45.&75'from top of Fewl Q"tttgw►adsp m its 1 4wvaea and sora o vsitb tasznM1y Saar{3A)1°k.SQ" (3)Three 4"butt hiagos on does Frsme located Iron renter Svm trap and barium and mi3e ro W-ps-Rer(4)Ba cad a"deans t}aaa boa w gt a lNprtsfag bet wesa nasir, midgm located 7.375',1937!-".wd 69.375"measwing from top door. and a 12"Rano batweeo group ofna&ZUna s art Wx ttd to ba*facet wd beele of jambs Salm"t C a drag%,.=Wed va sem:st R;,etc.r s e.""ling. Ceoligmdm: Single Door witlt Salt (Ire g) OX0 Additirana)Description: Each MW%ms attached to firma with fmr(4)screws.cam(1)p 14 x 2.5"Phillips ratm m stork screw and rb=(3)+t I Q x.750'phitlips oounta stink screws.llingm Paudt Dom paad mcasamed 35.75'x 79.MI2".S*Ifba pends mrasmW 11.15-A 74.0312' -vera A%cMd to does panel wridt lune(4)9 IQ x.750"phiilips a eaw stmt;screws, � Dam"h-A C-1dnpt?im, ��+!rfenal;�"L teL t+�Lf��taM�,dtf�j..'sa�+i.xi1 uh iuiza iqu t�rvity tti Iastallatiew Twenty form f24T A g x 2.5"enerr:P.A,��aM$'ro w�-m-.-•�� s- ..tt^» ^wt�acs. buck Sia(6)in tee ftamme broad and six in the sill located 3"from mala lamb ou � tads tisor is Sad VrA PIT tea'Fke*w Odmssed type.The tap'&bWom side7it es,and 3"fibro ascb and on door(toad.Six(6)in rash sidelite jwib located �y rails era PVC plastic()DmvA g PAS74)trod rmertaed 1.590"wide x 1.2M"b* $.1875"6om oub mad 14*m omua 9aaeafler. x f m'WAAL lu hkw two is ctmdruciled with care(I)Piece of PVC pleatie eta cc (Dnewiog PAS73(8)magmmr*1.590"VA&x LM'40 out!rata pitwe of Csnamott NamhW 3 mil polyetbyiaac film was umJ to seal again::air leakage dwing dracuoal foods.The film W wooded(Dmw*WCAM)meRw*g 1.591'%idsx 1.181".fitgit x was used in a amana Ad did v rA tadlateaoe tits test tmft. - l fill Fmgtb•Thr ladaet7a to sittcbnd rvidt etGKi(l)paex td twwad � 'Wr")i 1.591*bride.x.787' x JW lesagth gad qm tl wwdea Psi farreaatx Test ResaFts CD Jx(Dr. I'341°widtx2 3&4'bilgltx24"kaon The ttkinisgtaed10door pad,Afaar(4)iitast*aopwtaabgtrhodtoE4& F�"°"hNa �ufTear i � daarbsltatasssZBothslcrosir oaltiztrtJcp6malbe a e vwylfiaCmx4 2112 AirinClbation ASM B2g-11 us CfmAv 3Qcfb%*. tsaxs IU'jr 40.73"with a char l/gfiaap ta�tg 13.3't 37.75'. @ I.57 oaf 'ilea tested speckm ravers m wmaecis the pwfmmrace levels speoAcd in AAAWtOl iLUM. 2.13 WASW Resistance ASM FW Na Entry No Entry 5.0 gpltlfl' Fam(4)3tva Minute cycles C_ z s. N Tego3 af3 Rodin proda ft aepmrti cnA-?WW-3 N O O cn 2.IA.W4A.2 lloifaowLoad Stroemtal ASTIR ES" D1R 60 PermsOaR Del'oometioar Tweoly four(74)+eoonds(off CD am Lodi x0ge 1001 LAW WOPSfPo W"W .175" 3M, A17`'.OSI" 31b" N @ 6OApsf 111111 h's .216" AW ,915" .414" 315" . O C" Lortfl Mid-apenofonullioa.Max.dWwtbkpnrm.sated IoodiDAKadtpra)=.321` Lauf!M�oCmultioa Ma>c.athwwble defleodo®atlilbeed(11175 afepeoj ffi,465"- b 1�0rA2Mld•a}tareofkgkatik.Mea.ellpwibEspa�u.seto2lced{0,4iG.cdapru)=3kb" - 3 . to 2 3 A714A Z Uniform load Stnsednal ANIM 1r3.7i-W 00 Powea t I ohmation Tin(16)secoft keds., 90.0 psf Pb"w All": 316" Ci l 9U4pafNogsaive :024" - z 7NW-Mmooflockatr LMe¢.allvweblepeme.utut loed{OA%ofspm)=41V r— TrstDrlec April K2001 Tea t omplatlo0 Deep: Aped 16,2*1 CD RVINI lac DvWbd drawings wen available for labo mmy records sod tomporisaa to fere toys sperm 1193v time of this report A copy oftbis nVwt along with top Socdow of the ted speeia mr will be .roe _.1Vjv'wby w We SpOOMM"Sm. This test Topm does net coamft rte ccai&Adw ofdi.k product,but only Otat toe above test mult_s wove obab"using the das*wkd bass wWw&and they inft to aoaopUs=c*06 the palbrrwmce eagvilumends(pwsgtapbs as listed)of do above eekeaaood specifh4(ons. 'rl Ce (fled Testing Woretoo'ies assumes that nal infesmation VmYW d by nee cliew is aaepralc and" => the Physical and cbooaicsl properties of the,ownVooada are azsc aced by t wmauafactm. x z C x6fied Testing LabwzWe%leachnstoplwBewcu O ���---- �,� a co Archirerh0el Division —� co ce: Eedara [2} N Sosthero Mi NW& (2) Ramesh Patel (1) File (1) "c PC i f �'�7 vege2d'2 Pmdtccts � HRTIPi?1STi1+rG ABORATQ� Arte ctz t-aoaw s c: ArchiteftrAl Divisim+•7252 hlmtomm Rd.•Im,do,F#.MV � � SWSIjk Fmm C1 MstjN;0_ t•Tam(2)4.3&25"Pine jambs and ooe(1)Ersatz h=kt,lbs bMd Ind sdt WAS s0eare d C (407)-*6-7744- ax(407)3M-7753 "� wii�cjamixswithforn(d).�623x2's�iaawb . 5i31:,+uifusmbW4s1C+�P � Web Site:www.cttaick.rnm � ffiTIAIT+&73U1]'�c9thaVH 2ta�dimClmi E-raatIl cffitrc t.eom ' EL' IRrFort t4aratbea-MAMOW a ® Si _Pala C11natrwctioo:T1te pmrl is QummttcW off m(0,040")&ick sem.Tae inkriar patina of .. Xgmrt Km Jd3r A xoot each asks lcae plad is MW wide PU EDO='17ta rap do bat=rap,are PVC C33 Ptasfic(l mvft FAS74)anti ne smW 1390"wide x 1.200 NO x*010119th. Bade abler an PVCpUWr.(DrawingPAS?3(5)and mmued1.590'widcx12W � STRUCTURAL PERFORMANCE Tf.ff REPORT hio x fo ler tb.The hams ir:peat lnda cksr 1i91u of 5.875"x63". MW IN ad chkat; Vadam Pk*dmcty Inc aId all was sltaued to the jambs wilt fam(4}.#r25 x 2'seapks in mat .Sa P.0.90%8906 A4jun ha ark Dap iolaiag sill A356250@Y wit)r a VH-2 sideiile seat.A f=(4)&m � Greaabom Nc 27429-me nrcep was wed tor8c5diaoa nil.Tae dIcIfae fiacx was matmdtawa umn s<! Flbd glafa Tloor 1Pilh � F+�w&Rear($)1'8 a 2.5"drywall swam laded 107,303',5 1'aod 71.i'm M& Cri Product T+ppe and Sorkin Na a Apecisky pm cbmw 0I d Taaert,and jamb.ck a(t)it the head and$13 kx+eacd ural-span.. Fihia*M Side Llkx wkb sp-i tltx Gimes buevt, Hatdura Framtta H611- RW 65-1 2x bmwin8) Glazing. i"lanenkmed TmvemdGlean.otamat;agoftwo(2)Idn o1'.125"wvmcd$tan+ ?3tt"rir srxacr�inrArsesdet+u:tfi++rlxa«sheram±.(t}.�n"r"sb.+s+Rf!rS tom-' Teat 3pecita.Gone: AAMA MA 10111E U-97"V,36un s y Specificationfior Ahueinam„Vinyl Vl eatbar Stsippct IiWtt: Um f tl Psacea£w FF Ead+rsa t�E8U6S9 (P4'G)and WoodVemdnRx end OutI3oaE'_ Jambs'Two(2a pram ofwmbantrip Fadarra QEBD650 FrameC.aaapoaaets; Tico(3)4.5625"!'amajemlrtauiaue(1)*mvihaldc.'13tohead andsRiwasmmadtn SW GoAkmNtA tlro jer>des aviBe foac(a}.0625 x 2'sffiplex in each ersatz. SiB:Adjustable oak mp Ebxdware&Location: (1)Titan I awbalt ia+aaod 40.375"from sup ufpmd i urertng stIt Ai5b244LP_The dxr 3ntan tsfd aide la0s wars rm&d bCai:-w tI&with. (1)Titan Laochb11h%*b Imp handles Jaraetad 45.873"furan wp of Vaw3 -25V 03, apearr fit-bdmam sad.carne who twenty four im)#"x.$0"eatragatad (3)21ace 4'buK kimpm an door fiamc Loud Jorge cedar from vp and baamcn mA snitsiagrraps offv11r{4y lama 2^scnvafinmhmtt voitb I i,spac318 f, aa -.3,t 1"it,stlM?r betaeer'`"7 of�L.'Tha�sur i �to lmt Am.*m lea roidep�beaned?.375,38.375;Irl 39 375"mm t3aa sup ofdoor. o/jamlas. s3ea6uat: waa used io peal umd sdo n tab Opening, r7 E` bus = Sittgl0)boar tcit6 Sim Limn(Iasa ) 0300 AddifietW Deser"em: Eads hisgo nns Wudmd m frame wilt fou.(4)scrams,est(1)410 x 2.5"phiv* oomttrtr smack somw and throe(3)910 x_750"pial im co =61-scccees.Haagna went � Panel: Ibaoc panel measured 35.75`x T943 Jr.Side llle pem b maLv red i 1.75"x 74.0312" aumchad to door pmd with fuer(4)314 x_750"pktt4t caw=sunk=ms, Q 000r Panel Constrocdoa; I*patrd is otm#sttct+ed of fibm*M1(D.DW)thick skins.Tlta WWW MIN of IaIkv atioa: twenty fau(24)9 9 x 3.5'masse dr.vA==as acts used to sepia vPuk oma in nese -a ft&door is f€0d with PU fmm.Fhj*tar eaobmgd type_The tap&bm" bock. Six(3}ia abe frarrwJrad pad atx rn tiac siB carats+#3"fium rarh jetnb oa aeddfaes j M&ars PVC plastic(Drawing RAM)amt vmwed 1,590'wide x 1.200 high and 3^from each end oa dos hand.Six(6)m cwb 6& tan jamb laeatsd 5.18751 fzm I Stu k%*-Tz hinge stiho is amstniabd wilt am(1)pkw ofPVC plastic eadt sad#4"ao aeoec theaeatLw. co (Drawing PAS73(S)mcsstu jW I.59O'uit#e x I-2OO ho sod ane piece arwaext *fit(Drawing WCA31D) 1.591'wideit 1.181"high x roll Coanaeut Nora6ati 3 tail pdy0dt}fit bent yeas rand has curd against air lige dnriog stmtxnral)pads. Fine fiiss -3 look nm hex lance is m adracted will otm(1)piece afROWi(Uxawigg etas pard ah a m merit that ad eat ittfhea m di.trot rem&& o WCA2{t}�1. 391"wide x.787"highx&I I.Vh sud,,w(1)"ad. a Trot ND iaakbmt Mixw*WCA6D)mead 1.S9i'`wide x 2.364"high x 2O"long. r a ° T of Teat ! Measestl AlGnrexl f he fiburgim""is gbwd to exw p=d.:A four(4)fm sweep x=,ftvcb dt,0, 2.12 Air InfibrEdou ASTM 7 .45 oftow .30 ctkww, dear b*-ia3L Aotb skipsxkdoelr Wo mtdt odw at loci. .'."o frame;imat w 1.57 psf measmttt 225"Y 60^with a akar tight opmft 17.bW. L 55'. I c tcokd spm mean mom or ea+aecis the�icst#s apea6ad in A kMAl1 O111,5.2A7. 2.13 Water Rtsigbmm ASTM FS47 No Etm} No Baory 5.0 gphw Paul'(4)frm mitade WIT=2.86 Dar ^t7 C. c :z l ,.a Pap3af3 FsdrasaRaa3acas l Itapmta C71.&70W-1 O O GTl 2.1.dTt4.42 1)it Load9hvctural AS7'i11i3w" DAI60 PemtwAwDofixnw6m Tvent fcm{24}womb la" O Lail Lm#2 7 aryl 1*02 C=) !, -60.0 pepwiti a .180' 4I3" 006' .002' 318' f V 544psfNcodi.ae ?33' .489" .ow .074" .318• o rn Lacdll W-opm at3mI m. Mm allowable perm.sat ar fo.a(4.476 a£epao)-3z i^, v Lo*l W51Vsm ofsoallim Maas IMPP*We ddkdim at kmdQJ175 of qwp —,465^ 3 Laa92 NW-Mm of loclaa7e.Mas-allwwaW papa,sec at load(0.4v/cfgm) 3 ib" Lia O C 2_IA1l4AZ L fbmLoadSmabaal Asrmem0-49 3 Pa mdxmt Defommuom Tea(10)soccub loads rxs 11 @ 90.0psfPoswm 40.OPsfNeptiwe _4I I" 315" hbj-gmofkdcamMimallowableppm-sdsdloada4%afgm)=16 L Test Dft: Apri:l',2MI E x Remarks: oetaaadd>Iawomgs.arJa ava7able fie lsbaramsy tecads and mmpaslam w dse tarot spxbsea at tlwe tiros ua-%,Alm repaamm"aatm am"of[baa tw apoeimea vQl be nlamad by CIL far a period a£fav(4)years•'Ihe,es b abtaioed appty only lode spaei i ted. 21mtot npaddew riot Nm atataioedvsirglka dae�dtaxt tme�aed 8wy iaaabcale taoammliamoe orifi rNemfcr�cc 'i'] to --tM pwagrapba w HM4 of•tbc above ie>mwmd . - x CatEod TaartiaB LWMatosies assrames dW all it bmstlm p wndc d bytbe meat is aaaacape a al that Bae phyxkalandcLm&Wpoo"tieeofthecmgpooncmmstardbvaBse _ CD O awbfiod Tmft l a ion he. r -_j Aw CID ca lab cbdmqbw mwftBoom* � co AydiftcunW nivisiom CD ro sx: Ifiitua (2) Soa®mm WAwo& (2) Ramesh reset (►) ,f . F& (I) - .rte JUN-27-2005 MON 02:06 PM SOUTHERN MILL WORK FAX NO. 713 983 7902 P. 15 Vertical atackui> -In6win 9DA00ROMPONENTSYSTEMS —�,wa, „naeamwraePnw,wN ar 11 PhwC+M JGoa.eNCYi, ruil]: DOOR9Y5TEM 5PEGIFIGATIQN15 ' ,+aW�,a+Pnaw�uxnN rov7 FOP" I 5OUTHERN MILLWORK rµn I ✓� 6TV —� --i 'TYPICAL M/.I a IND 7oUH dmro Ngo[r". . _. .. — :c ifharnMllhwork �• .,xaN[a;,q;� �,.,�P "":;,. 1 � f�ev.Laakll� ��-1 acals: n: m�oxii .,u,yruaaa pittr3;Q-11Q101 J VANE Vertical Stack �Otattwing Jamb f_►i nomr2ions ��anW nn[w.tNtnN 0047 � t[mJ,YI Utlf '..-..=,��—��..r � •`...•.ii' ��.:�i�_ '.iii _..�:'._ --•�.. Sous Warn MlNworV' _ 9 xMhe 1 Millwork RAV.Lsvei:Ik S ale;R <Lavek IR Scab; .am[a,rM,,,,^Il Rate:4t1QlQl )NE d Daul4l10/01 — _ NPN . r'S '�tON 4t)Jt)Utr�2�er�. '�7�'°'° —/. ANON ,.. 101011b�'(f ,,•"°,nrre.rm,n�. YJ 'IB�Cj SII �3�TI.nTel !___'`'�►1��t /r �AWJJ(Y i;agsnoG _... Ypoo IIIW ujp4jnoe - MVnu+R:ta 110w333vun•nK'nn � .......KI +Wi. nK.tln,Jp W riYM ^I I,VI r1 .."m'�.�r�.r v- ,._k�_T.,.—__ _..__-___...__..._.�- a..l _;.T,I:I:AInW. •,; - .Inr>�n•- - - - — F, atlnwr IICVo"i[I177�'� '.y�1 I� I I•%.INI`.Y.YNI I maJaila; � 3 a.r, �h19-)r M.n�'� \ ..-'^•'--(W]V'UQ uli7vN`ANxNu'/ OUAr f y�p...l 'htlWvinW vn7n;glq•pru Fla'nrnrvN!?9� nitlrclpll •..wr]IFFv.-.�^ .......rItml.)'null � V GUOISURLUI(] njjQrlc3 Pug ao0(] emwnrwhwl my riON t0lOUb�3bU �3,�Nl0lUIJb sled "� g M, Hf lana I n fir'-L- +oMIIIIN yanoG — YPOMI IW - .•• _ 'nVl7lf IV17NiI:BW:1:7WYlL•'fNF.OVF YY'al'7T.gl18� � v180 MIL"9901•: Vv1.703?LLyOW 1.1tkk7r9d r nsuu.,rnm�et<ya. am— __ ._J_ •- -__J � :fir _ M31h NOi'lJ:Y'AYNP -� •I a Y nH-- ' MM• I .Mt d4. t.:,, � � YVttltl761nrtivanNn+ V I :,NI'VIi1W4C:1•JY<I�r)f.V7'/AAI/l V��� %' I I L=w I tw I:nn 'r I•�,IWYi ':1�+• I +.1�h1.M f I ! { i qT. '� 206L £86 £tL 'ON XVA MOM 11IW NHMOS Odd L020 NOW 5002—LMIII' JUN-27-2005 MON 02:07 PM SOUTHERN MILL WORK FAX NO. 713 983 7902 PL 11 Lorre ated Nail Placement -1/0-L/0-1/0 Head and 6111 Pimenpions-1/0.3/0-1/0 tlKwt'M 1.- a,G{ 'R�r��' (/yip�+�jj���LL•.ane2xcr(n� .,..-" ,,..,--�-._ K�Y!<+I __•� tir' '.'1•JILL.�G11'SfiEJ,(pF� ♦bqd' lY ,Ot�oNfCLkNbad M,+'A I, ,IwraoNtro ! "� w.r,enu 4• —.– ' --11 11 --Iwrwl � raeamuauwYtNa•.aid�a;-y'•,•e•j �a�„rn+u ,H'OdL-A%F�•=uxe'wv+r���1.9enff+E1 u�nabnc r�,mx,rr+,as,M,u,wxY,�L'rttaM�,mea ,o bbn,•w++r.w Y.,,.or erak.a xta�H.ab r!rutu�mYrY�caxeanrrnaNta,nnvnu,eloeurr:nowy�r�erxrK nor; �— ~�_' Soutl sm Mlfiwork ?c mhern Mlllwo6 -•4ii: kav,Lwsl;IR yM- 5c:��I � Rav,Ltivel;IR .,W hale: q «,., 1Le:4/10lOtpq `'F fy�, � PAts 4tfOt01 d�N� t� 5111,5idelite Seat&Door bottom petai15 Mull oaf,r De aifs A nde��7ar�axKs,�nl.l:oN,:uva'Y�wwGwu W.,.__. r . .\�1. N,�Pi:'xnr nu.x6YMLE i-MT a •`— II! l .u. •� d� P Il�-� I'a}4ltl6ApIXtt/OLIfSWIfIGnUMI'fR� I i.�.YnY•�'+N RMI � ulmben,�nuar.*.i a I�101't, V�.. .._ , ""•bub \� PRDvd�FPpY:eu�mlwwuwOLx .. .� —.•.�- 12 _ Sout iexn Millwork _ "'�^— � uthem MlliwOrk Rev,Leyel:IK Sc a{ q �� f Ev,Level:IR - Scaic, �,ww ps�tc;411D/CJ1 - lNl�I .Y.La._yn . LhYGs a110JU �_ NoNr 12 JUN-27-2005 MON 02:07 PM SOUTHERN MILL WORK FAX NO, 713 983 7902 P. 18 nor Schedule:jn5tiflaVon-VID-3/0-1.'0 Ur 1% .�I 7 --------- -- WWTM Lwm .Ift-rham) IwRm_f4ba,M 14n, mv4,T441cr#ftLM-bW VW"OE22�OYCTDAM t 10 14S-1AIffT�-1=22L C" E,puthom Millwork 5ouThor N illwork Rev.Level:lIZ S.6 4 �01 -NQNI- 14 VIN.J. /16;01 NONE Unj%#2(1n5w1nq1L#11 ut5wiral _Un ts#3 1nswinc0&#12(out;,: InI) I dw ..mare om wr.PMR 014 #11 Alm Rev.Level;IF, Scale. JUN-27-2005 MON 02:07 PM SOUTHERN MILL WORK FAX NO, 713 983 7902 F. 1u Unite•#4(Inswing)&41� Ou•;5win — _Unite#50nswina &#14 lutEw•in iY 1 1 I I I I i i4,lia .uulif�r I i L:'n1 I I it I . r�h 1p j �I•" , I I. arrlpi CP_ N I .I L. .1 •4C4LG ..,....,.. i �' /L r—wAA+rtr.p,xnrxtru warp up, � arLurc IXY'A�eOnOw.9WfJlrW—••j'�]'rw+Yt+VnfNwwM'Yl,m I; L/ w.wa,wr.•„wan, cm.nnrlc..,.iwruu,e� as wt,w: �rrlrzny / Aulm'�rnrw.r�w,nwwrynl nnx.,wA .. ! .,wf,.,Icsc,c.,�.,.,.urw.Rr,1 �+w+aw..n,w 'I j ww,vww.l.wu.,y,•an, r•mwalp:ma+w..,x.xau• aonrteelL�.:xeu.artinr !orrYAiw�raxe.l•lenraol.r ,/;'� VU'91f}�INf*yfr'DODlt SWEM&1 _ _#4 /'A uc-&Nlo NSM*XORFYTTOA #5-- Ii � t I � I =,.lat_m a.,c wrn w+ev- � /'wai.�,soM raa •� �:aruu uuwxn,rr.urnartm f /IurxpnrrrM nt>�t' w.x..,...,wan, �!,,...,, _ w p.fry�...rwn rw G a•.w,lr /!V,hliit Ckl YArkra'tRnl vwW xha.,.ww.r w.4 /.atlul�ry wN. tl 1 K.tWeuLL lLw:.n j�' WJ/C+1K+OLI($VAX6A+l70K SY51kMa L” #�� llL,MQ'irOWJf5M9VG6�1:5YfiYGMkN ••�� ..5AMEDOM&RDEUTEEAFACOVE .•—. ___.---'-- SAME OOOR6610ELI4E6A6 Ari0vE •- - SoutFfF1 ����,�,, r,them Mlllwark 0 t iiia D 0/01 dDNE Unity# (Inswing &#15 Qu-Lwim Unity#7(lnswinc��&#16 ;C uwinc�� 1 A,x YIx,AAnpuMDw1T w: CG,u paneu-- I I , rrelmn I • ON i 1 ' vwu we„IHM'A , JJ �•/I 'I.1. ._._•.�.�..�+ 11. /`� :0.r,aiw�.�IRuuu Mu L.,OOrwnw.�_rn..uw { •/�1�-'wua�nr�Wµru.twrl lrrrY=_.:;y..0/.-_:�V.t:.�l��_'-` 1�,� A,wr..ww«ani +/• tw.m.,.,.. �,�,� :. A•n, , `�IWµf!LW%A,PIA elne.n�u.e.weaufe n; rwlwf,uGwmtwouaer �xaua:e�:nawurani �v'rw�wnanFw„vLwtq.Y #7 f��vu•vLrarou,.awru.rxnle:m.,T,.�++rn #�7 �p,�vu'�rD•vu wswwLi WLk:rn�eM,rr �..._.. .. ..—.. I I� 1_,_..._..._i �!.'._,.._:.., a ---•� i�.r,.•r. � ; ' ...........- { rr-��m h�nm:�ox.-.ur.le�,er-.. 1xauawo�mixw vme M1n, f wlw,,.n,w„xl r�,.�w; rwNn1 uo, / I ua•.eontwnuw _ r wla.lr,raL�rt>MxaR , •a'earw.an,ai,re,�l',vnr, #'�J �„��•.,•LO4 Aal., La,..,�rA«.v�nm,.wal,..R .µ /^ IIO•Jr6vf)CIV(6WIMfiGDDN.5YS7tMAlS p}�V:•3!U•1IUUL,ISWP,f•.VLUKSY•lTI:N•M '71CJ �� 6AAIE FOCdCa£+DEUTESAE AbWC• --�.•.�_..,,,r•- �� '�n2 C+OtM.¢5lhint5 n�nnLSvt ... - South an Mlllwaek o rharm Millwork Rev.Level: DsL �— q-19 e.4110/01 NOf J5 `9 Lilw/,YrrnMltUlw, Dace;4110l01 a4NG �Q JUN-27-2005 MON 02.07 PM SOUTHERN MILL WORK FAX NO. 713 983 7902 F, zU Llni #8 fnswin� &#1 i�Ut win L1nto#9(ln�w�n &#18(OA Lwin r_... ��I ealc'MOGIKfwugwrn i I I � Ya.nµa�(t A�a•6lMw� LI I it Vk41ilY �I �.. I OMYRv i•_) I � t a rp [tlLLb;.,Y-a-K) n44exYLLene 7acN n wl.ti.r•.,t... ../�,,.,,,"yyl�.`..4.M vn'eaew1.smwux•Mnx / M1I mfantM�Mui� {�. Gpcv LLwL�Y{rpAl !pM1rwlanumt+AUMtlktlW' �[3 _v().9ir7.voxrrHNNGLi00LL,6r�7>:Mrrd ♦ _ _ 7' A vu yw.tml*wW.D00KAvsTw#9 /, - -+-----YF✓-- _ •Jl_... �.. yy.Jl—_ Lnulnnr 4x�roe4afv,knt �rnmrcma�cw�.r � taetneeulmom.Qn� B 1rO.sy.vnot�.wlrr,Uootesrsmdrta _ #'7 ,ro•sra-troa,rtsvnnoumms,�,r�rw _�$ b/utf000ituittPDLITf5A6nt76rY � `y1t�Gi6Pt6010EufE9.�5nnOY6 Barium Mt kva* Southa MlllvAA ftv.L ft*IR q lieu.l4VA�:IR fx,a�s r��y P"4110/01 ..! pnta 4/1Q/Q1 NptsE 2-r �1 FAV 2of2 EmboaProd>cts ER77M ESTtiYG A80RATtlRIBS p C71A-?Ww-4 14schitectural giviairrn•7252 Narroassee Rd.•0fl!do,FL 32827 : (4fYg 395 7741 Fax( 384-moi 1 SideRte�F'rame Cmaxtrvcxiem.Two(2}4.51425`Pioe jambs>mW a+r-10 flame header.3iw 5eod grid sill was sxarned (W,,Site:7 4,fa arch.cona im tba janslis wiTh four(41 4625"x 2"staples in eacb oorotr.Sill:FO845fibA %lebF,mait:c1larch.com &AelEik Panel Cabatracdon.Tbv panel is oonstmoad of fibcrglass(9.49tt")thkk skirls:.The ittitsior cavily of � wh aide lite parrot is filled with PV frrato.The top&botmm rails art~PVC deport T1aioltcM C(T.:4-?WW-d plasia{tlra+rotg FAS74}at�d rnr�wrad 1.544"wide x 1.200 high x full length, Arpor(Dsic trete 27,2pOi Both stiles suss PVC phslic(fhswing PAS'3(S)and messured 1.594"wide x 1.204' big);x full hag-M.The frame itestrt had a clear light ope ping 5,823"x 63".The head 'L7 STRUCTURAL i!aERFORMA PKE TM REPORT cad sill was:catered to tae jersbs with fm v(4).4623"x 2"suplas in rash oonwf. The � Glint Ivodara Prada ::delfts forme stns sewz*d to eacb insert panel with fmv(4)4 8 x23'6xycanll saes M P.MBOX 9905 Mas Tisa tvcatat to",30 5`,51"sort 71.51a each)amiix Two(2)in Ow head and all located 3" t= form each end. 3 Greenb0R6 NC 27419-M8 t r7 Gkaing: 2 lasulated TanperedGlass:cunsistingof two(2)litts of.121'vmpeted glass, PC Product Type and StAev Manta Fiberglass X)vorsrlilt Sp-Wk Gland Hal£Late fsaert,and Nuzym 7$0"air space with interior dtcuratiytc#:cess chermcl.(0.549'falass Bile) lFaMSr Ski sell Like outh #B{ � malty Glazed Insert.Fatdmra Fraises HGtI Weather Stripping; Head: One(l)piece of�asisarstrip Endura QEBDM RFy� `\ " " g 1 lan'tvs-T,•o(2)piccer nFwevi`".*Vtlg 1:.'r�'d m QEDD45^ t- Text eciftratsoaau AAa m�75F +�m�ama,irtayl SiR: One{i;pie=ofwcabomtripEndumQ£9I365$ SP �dAtN1WW'UA 101f1.su.2-9?"YOi $catiixn feel � " 'C) and Wood Wwdows aus:Gissa Dotes Rardreare&Lotaliosc (t)Titan Deadbolt locates 46.375"from top of pant) >FnMe Compeaeata: Two(2)4.3625"l=ime jambs and one(1)ko me headar.'Tin head and silt was aecrs� {t I Titan Latebbolt with fever hatsdirs loeatad 45,975"from top od gsmet tat'rr,,....a"t,.t.t,;.. ,.e a.....ri.......i.,..�a,I,m•..-- ..::`�-:::,._..........,,.•...... ti umiamm wtw reamtnl,tea to x'"Staples in eat*coater. Sill:Fixal Ordswing m idspen loaded 7.375",38335",and 49.375"measuring from lap of door. Btmrper of POFA566A.-at door frar"r and side Btcs were muffed track-Le-back with a 250"plyurood alienee iia-1 tweed end secure with twee four " corrt>gatad rude in tie (24)l"x 59 Smdank Caulkiregwas Wed to seat anis imim weigh opening. groups of four(4)loaata#2"do>sn frwm boat]witb a 1-spacing bexwaen sails,and a 12"datawt bstvven gtosu nfrrails.The no lle mr i e-'W t.>Mr Addiflerxi Beres iptioo: Ta::tri=ge r t]t ttB.teJ rw r, w+ib RrAr t4)strews,rue(1'i n 10 x _s"pnr ntps front and but of jambs. aoctnter writ screw and three(3)9 10 x.754'Phillips cmader soak sarenB.Hisses r l Couftarstiom: Single Doan witu Side Lin s(Oulrxi rg) L1 o were atisched to duce paten!with four(4)K 14 x.759'Phillips counter su»k acre,+:. X lnstatlation: Twrnty fa or{247 4 9x 2.5'ants:;dry ws#I screw s%mrr us-zi to secure specimaa to test Paaef; Floor punt measured 35.75•x 79.9322"_site Tete pwrls rneas and 11.75'x 79.1#312• buck. Silt(6)in the f rsma bead and six in the sit!lrb:atod 3"frmrs each jamb cm Q sirlat lex aaa Z'4S-yn e-I tnd nn,4 m?h!a4.cj I `--jn T5.1975"frost each am Won canter t6�sfter, - Door i`asri t.oasQ-netlma: he Pair-)is cems6rrssetard affibrxg)ttss(D 43if�}L'hick skins,Yhsiotttios cavityof earls door is filed with FU foam,Mud or embossed type.Tice top&bottom W tails art PVC plastic(fhastimg PAS74)and measured 1.590"We x 1.240 high Comment. Nominal 2 mit paltzthyleme filro wss used to scat spiti"st air tea.-AV during struawra!mads. 'The filen was used in a maser that did"a infivence the test results. tai x full ipagth Tim hinge stile is et)sstrvCW with one(1)pieta DOWPlastie � (Lhav*PAS t3(5)tarastuitsg 159#3"wide x 1.200 bigtt and untie piety ofwoodGat seinfnrccmcat{T7r�arMv9'ttttC113{!}maasur*1.591"wide x 1.181"highx fid] 00 Performance teat Itcsutb 11-9th The 1-%sole is twostructod with otic(1)piece of wood(Dmwiag Parmaramh Tia 'Tttk of Test MIJW -M"D-fw- A112AW t) WC;A20)ming 1.541"wick x.387"high x foil 1eogrtit and one(1)wooden tQ lockbtmt(Drawing WCA60)olvauring 1.591"wide x 2.364'high x Ar long. 2.12 Air linftkrafiun A"E2$3-91 .01 cfmv -34 cfm.°fl'. The fiberglass skin is gived to door pearl..Bed skims interlock into each other at @ 1.57 psf lockable.Winyt ftaane inapt meastmu126 875'x 365":civet a clear liebt opening 24'x The tesbed specimen meets to exceeds the perfimuamcc!e t1s apxifiat is A#i fAl l lel r3 5 a 97, 33.625", 2.13 W'attr Resinume ASTM 0547 No 1~ntry No Bmtny, 5.0 R-le Four(4)five mmmie s Inv WTP-2.85gaf "L7 I'�; C— i N Pagr3 a3 EadmaPtodu* A x C[IJr700AIA C:) C:)O LFI 2.1.4.214.4.2 UnifoQrolmd StnsumW ASTMF330.90 MR 50 Permematt Deforvrmson Ttirap-four(24)swords loads O Dm W A�lowd Loc&1 Lx112 EOAI LO02 O [a) 500padPosisiva .184" 345" .003" .992" 316' N @ 50.0psfNegative .178" .606" All" .136" 316' CO LOC#1 Mid-spm trfmullimr.. Mex.allowabloparm..oes st'load(OA%ofapm)-321^ .. Loa�l Widapmofmnlliom.Max.allowmbledellbebioot.at loe�A(Uiticif ")-.459" LodC2 Mid-spurn of ktekatilw Mme.mllowabk ppm.seta4.load(�A56 ofttpam)m 3 F6'` O 2.1.4.214.42 Uniform Laad Sim mml ASTM 193" Pett wad Defoamoden Teti(14)mmnds lords h1iywed- @ 75.0psfpaditive 048" 316" ' 75.Opsfhlagptiw .143 .316" Mid-spanoflockslik.May-a]lmableperm.sd l land(0.49iofspem)=.316" L-- Test pate: Apol k7,2001 t— E Test CucrtWiom pate: Apfil 17,200 k CD time of thisxeport.A copy of bisupors aloogwith reptesesitativeseetiomsofthe best gndraen will be retained by CTL foo a period of four(4)years.'1Le res&obtained apply only to iho specimen tested. This test tnpxi does not ocrosftm Certification of this pmdm-4 but ally tbat the above test molts wore obtaimed using the desipproed test methods and titcy indi=c eompitmwc with ibc pafmmamm .. regairerwtsts(pmagaphs as listed)oftbe abova re b mead speclficatioms. 'TI 9 Ca fsed Testing Labeaatories assumes that all iofon"o provided by the client is awaanbe and that x the physical and chronical properties of the oomri meats are as skbed by the manufacturer. O 0 0,ifr 6 Tt5;:r g 1Ataa:::.escc , Chrisbophexuaamen. Lab}Aataget L� Atdhitact ml Division CC C DC7 Endura (2) R= Sot►gtem Millwmic (2) Ramesh NO [i} File [1} ^L R f1: f Frgc2cF2 �dmul'tobaRs EKIMIlj EMG ABORAfi(}RIFS !' Rowell! CR.A-MW2 AtAldischviJ lDkgm m-7252 Yduconum Rd.*Orlavaltl.M3= Si Three C dlm,fv.+o(2)4.5625'pine,ul&wz ow(I)fmlw itomder.Tae head and sill toxo sec XW t 7 Mork W-7744•FAx(W,,}Mil-Ml to tw jtmbs+A smg(4).o6xs X2"nVie, n,era WnW,571:EMS66A � c Web Site:www ctlarcb_eom 1� � Email:cOwch.com wigHtt roci Comondbu,The pwrl is tmtslaucted offiberglass(0.09n thick skins.ThtblMim cattily Raliwt Numtaara cr&A.7wjvW j 0f eacb side m,psaei is filled with Pia fns The tap 8c borism mid ere PVC CD 0- My yy,zpai t r ph tic(Do%iag PAS74)and measured 1.590-vrid e x 12DO NO x full lesth. Batb miks ere FVC plsstie(1>iaw*PAS73(8)mai tneamwcd 1.59(r wi&x co STRUCTLTRAL pERMRMMCZ TFST RgpClRT 1.2W higb x Mi Iength.7`he fume io ed bad a char Sight opcaaag of 5.$75'x Q*. The head and sill was wourred to She jambs with fo*4)A625 x 2"dVks csftt Ends"prodM#s,Inc. ae t=ech corner.The skW tc firtm was smucd to each wsw t portal with f sa 4) � P 03MM on 4 8 x 2.5"drywall screws kwated I4",30.5",3)"add 71-Pin tach jemb.'Tim(2) O Growboro,NC 23419 A4I$ in ibe head and sW locadod 3"form aw k add. Pt ll Type sod series N Giadae: I^bwdetai TvaVetad citta.consisting oftwo(2)litos of.125"was avd t.� Doer $}+eedrkity 3l4 GLmed Ora inont,and Tot,4M 73rxa spear with kWordvwntivvbmwobAmvtL(O.S00"Glees Bite) � Ffbargk"B*i LN"VA Sppft bly Glossed I ..1,rndon rnw M RGD- � M3S(6',"t#p"dmM1or.tag} 1'i`exlher?ir#I+tt%a:' Mead: e]ne(1)Pic"*fwMrberxApRod"AQMD650 Sasebo:TTM qj pieces Uvecii"Wip Dewar QEBM54 t~ Ttat Specil4irafboos: atp AAMA,I Vi?A 1011)52+37"Valmsbty Specifststisear far ,Vl sill. One(1)pivM ofwc ip F.adun QBRO6S0 � (PVC)w d Wood IVmdom and Glow Thiers.'. Ca JUY&mre&T.omdus: (1)Titan Deaaboh wceo(a 40.375~finmu Wp of Fawl � Oaf rwel >� hwr(a).0b25 x r aulsles isaach exirnar: Sill:Fiseid Oadwrimg (3)Shine 4"bua hisser oa door hams totmtod 10"aa Detect inn top mtd iwuan+ffiud Bnmq+a alli PC}Fl45i411.13edeor fr ac red aide versa mui#ad i o-bscis wii6 esidspets located 7375"3V75",375",and 6+9375"nxssmug mp ofdoor. a.25U"P�'�d sparer its-§e�reao sod scalae vcifls tvrmty toarr(24)i'k Sfl^ nn"IMPled arils ingrampt of tear(4)loosted 2"dorm free trod srM a l 4.,es Sessksnt; Cw kwg was orad to stat envie into uMO op ming. bttsveers srds,"d a e2'dtsftee adtiaerat VOW of mile.Tire suds we ,"Md to berg froacta:dd0odtfsszafjanbs A:dditivxWDxseripO; EwAkn vms owbmdtoftwewithlbwj4)scrcros,one(i)8)0x2.3"Phillips -rl Cnnl�aratlame t uaomw stook sct erg aw tinge(I)iv 10 X.750"ghlllips caantto avak a-raws.MOBM mase abated ted to door pawl wick four(4)#10 x.751'PWfiiPs cmager mmk scarves, x Single Door oritlt Side farrrisB) OXO : Ileal pemei mea s+ad 31-75'x 79.11312".Siideltse panels mmvxW 11,15'k 79.0312' tasiallalion Twsaty fatr(24)d 8 x 2.5'comm drywakl wj"s vmm used to wcm specimen to est p liuvor piry ti C""-073u a bwle.'Six(*)Mthe him demo surd 511 in ibc NM itnaeia i�"si3 u as w."=t I?�Is�of f76agom(Q,p9r ehtek sktaa.U.inter or CwAty of si&rtes sed 3"fmw seat std on door band.'Six(6)in cscIt sWetitalm,b laminal � Tach done'is filled wilt FU famm.Fiwh or emboeacd 47a.17we mp&battam 5.1575"Goy,each and 14*on ceatar dmoobox, � tails ata PVCplmrtin(D aadagPAS74)mad woor od I5W wide x 1.200 bigb .x full kvOL The hinge skit is ovasMmod whit atx(1)piece of PVC ph xdc Comment: Nominal 2 ail polyribytcne fare was ersat to vW against ass kakatp dining iftwb ml loads. 7Zsc film 00 ay (Dr i PASnM su-atatg 2590-wide x I.x high add sae Pte=of wood wam used in a mmsursw the did not enttmemoc thin twt n=Its. W 'Wlcn"W M-wingWCA30)mmwi g 1.591"wide x 1.181"high x hill a 1 77c tac�is canstntato3 Wbb ase(1)piano Of foal g T"erfomact Test Resales meatouiag 1.591 wide x.787"high x he Iwtgtb and MW(I)woodw t� Iwdtbax{ -lv*t WCA"mcwtiog 1591"wide x 2.364"high x 20"1otg. !'aavUMAM Tale of Mq*W IYFaa�reei The Mrgiaxs slag it:gbte3 to ISM panel::Bah 24d.intciircarac into ramuli othtx at )nclesdL--VIMOf--iuwvwascrd3SA-x40.75"v thacieerligWOpeningof 2.1.2 AirbfiMstioo AS7ME28"I 4ectm7Ra 30amm. 15.5"x 33.75'. ig 1.57 paf lbs 6twxd speciw=marts or axes&IM pafformaxoe 1-4%epseified iR AAb hIl Dl&S.2=47. 2.13 9iamer Resistmat AFM E547 Na Eutry No Entry 5.6 Mwld&' Fru(4)aver mictda cycles YY tY'�1-A��f1 -,✓�� CITY OF ATLANTIC BEACH -�' 800 SEMINOLE ROAD J N, ATLANTIC BEACH, FLORIDA 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 05-00029498 Date 1/20/05 Property Address . . . . . . 1879, BEACH AVE Tenant nbr, name 4 'BECK EXTENSION Application description . . . REGIDENTIAL ADD/RENOVATE/ALTER Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 14000 Owner Contractor ----------------- ------- ------------------------ PETRONI , GERARD DOWLING CONSTRUCTION CO. 1879 BEACH AVENUE PETE DOWLING ATLANTIC BEACH FL 32233 241 ATLANTIC BLVD - ##5 NEPTUNE BEACH FL 32266 (904) 246-1833 ---------------- ------------------------------------ ------------------------ Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee 100 . 00 Plan Check Fee 50 . 00 Issue Date . . . . Valuation . . . . 14000 Fee summary Charged Paid Credited Due -------- --------- ---------- ---------- ---------- ---------- Perm it Fee Total 100 . 00 100 . 00 . 00 . 00 Plan Check Total 50 . 00 50 . 00 . 00 . 00 Grand Total 150 . 00 150 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING OFFICIAL CI ❑ � �I 7 6wiling �TM .JAN 14 2005 241 Atlantic Blvd., Suite 5 CONSTRUCTION Neptune Beach, FL 32266 13y� r tel ■ 904.246.1833 --_ ' A DESIGN BUILD COMPANY "" fax ■ 904.247.3147 F L C B 0 0 6 8 3 4 January 13,2005 , A APPROVED City of Atlantic Beach CITY OF ATLANTIC BEACH Att: Larry Higgins BUILDING OFFICE Building/Zoning Department 800 Seminole Road i JAN 1205 Atlantic Beach,Florida 32233 A RE:Permit#05-29498 PETRONI DECK EXTENSION By: -- Mr.Higgins: The following is in response to your PLANS REVIEW COMMENTS on the above referenced permit application- (1) Submit details of design of tie:-downs for wind load. Response: The design details,specifically all Simpson wind load tie-downs,joist hangers, thru-bolts and column bases have been added to the attached revised Floor Plan and Elevation (2) List Design Criteria these details are based on. Response: The Design Criteria is as follows- FLORIDA STATE CODE COMPLIANCE DESIGNED IN ACCORDANCE WITH REQUIREMENTS OF FLORIDA BUILDING CODE 2001. WIND DESIGN PER ASCE 7-98. LOCATED WITHIN WIND BORNE DEBRIS REGION. ALL WORK SHALL BE IN ACCORDANCE WITH SECTION 1606.1.4. OCCUPANCY CLASS: GROUP R3 (RESIDENTIAL) WIND ZONE INFO: WIND-BORNE DEBRIS REGION AS DEFINED BY FBC-120MPH THREE SECOND GUSTS CITY OF ATLANTIC BEACH CODE COMPLIANCE Ordinance Number: 90-01-172 (Adopted:November 26,2001 /Effective Date: January 1,2002,including amendments through Ordinance 90-03-182 adopted May 12,2002) Please att c his lett r to the permit plans. lly s ted eyw Dowling City of Atlantic Beach Bu 904-247-5845 P, 2 •S�Lv;. CITY OF ATLANTIC BEACH isY BUILDING PERMIT APPLICATION (Alterations&Additions) Date: l Job Address: 'rc/ `'e Owner of Property: J�92 Address: �llST lho L Legal Description: lock Number: Lot Number: Zoning Dtstnc Contractor: State License Number: Contractor Address: e! ¢ �� Telephone: Describe proposed use and work to be done: � ,:2� Present use of land or building(s): Valuation of proposed construction: ` What are the dimensions of the added space: feet x feet Will the added area be heated and cooled? New electrical or increase in service?1G1� Add plumbing fixtures? Add fireplace? G Add heating/air conditioning?_ �� Is approval of Homeowner's Association or other private entity required? IV P-,- If yes, please submit with this application. Will this project involve changes in elevation, site grade or any use of fill material, or the addition of 5% or more to the original impervious area or the removal of any trees? NO. Applicant certifies that no change in site grade, impervious area or fill material will be used on this project. ❑YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. NO. Applicant certifies that no trees will be removed for this project. ❑YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT 1S REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board,which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if a pre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane,Atlantic Beach,FL 32233 Telephone:(904)247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. STEP 4. Please submit Building Permit Application, Energy Code Forms, Notice of Commencement, Owner/Contractor Affidavit if owner is contractor,and four(4)complete sets of construction plans to the Building Department,which is located at the Atlantic Beach City Hall,800 Seminole Road,Atlantic Beach,FL 32233 Telephone:(904)247-5826 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Page 2 Telephone: (904)247-5800 -Fax: (904)247-5845 •http://www.ci.atiantic-beach.fl.us Revised 8/04 [*] City of Atlantic Beach Bu 904-247-5845 p, 3 In addition to construction and engineering detail,plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. 1. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures,temporary and permanent,including setbacks,building height,number of stories and square footage. Identify any existing structures and uses. 3. If required by the Department of Public Works,a pre-construction topographical survey. 4. Any significant environmental features,including any jurisdictional wetlands,CCCL,natural water bodies. 5. Impervious Surface area calculations: include driveways,sidewalks, patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Other information as may be appropriate for individual applications. I hereby certify that all inf n ovided ith plication is correct. Signature of o er: Date: I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be mplied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the pro ' i of fed e ,state rules,regulations,ordinances,or laws in any manner,including the governing of construction or the pe rf a of c ction the prope . I understand that the issuance of this permit is contingent upon the above information being true co c and a pl pporti data v een or shall be provided as required. h Signature of Contractor: A Date:—/A5 Address and contact informatioof person to receive all corresp dence regarding this application(please print). Name: 4221 Mailing Address: rS Q Telephone: Fax: E-Mail: AS TO OWNER: /�� Sworn to and subscribed before me this day of fl' - 2 0 �7. Lj State of Florida,County of Duval , Mr? JENNIFER S�CHLUET H Notary's Signature: ,4A �l, =•; :. MY COMMISSION#DD 121301 'i•., o � r vrx a wow EXPIRES:May 27,2005 ersonally known er��N ElProduced identification , Type of identification produced AS TO CONTRACTOR: Sworn to and subscribed before me this 0 V�N day of ,20�� State of Florida,County of Duval Notary's Signature: JENNIFER SCHLUETER MY COMMISSION#DD 121301 EXPIRES:May 27,2006 Personally known ' B"°0dTftNo ' 1ndwwmers FProduced identification Type of identification produced 800 Seminole Road -Atlantic Beach,Florida 32233-5445 Page 3 Telephone: (904)247-5800 •Fax: (904)247-5845 -http://www.ci.atlantic-beach.fl.us Revised 8/04 [*7 City of Atlantic Beach Bu 904-247-5845 p, 5 CONSTRUCTION SITE MAINAGEMENT PLAN Ord. 6-18 —Requires contractors to submit a construction site management plan to include the following: (1) Location of demolition (2) Grading and drainage surface water management plan to comply with Chapter 24 Article 3 and Section 24-67. (3) Parking plan showing.off street parking. (4) Fencing plan locating fencing on at least three sides of property. (5) Location of construuti n trailer(nd loading/unloading ares.) `. G re(6) Location of chemical toilets. (7) Location of dumpster(s). (8) Traffic control plan showing access to project. k�-,4(9) Other activities where special conditions exist as approved by the Building Official. The complete ordinance may be obtained at the Building Department, at the City Clerks office, or on line at Municode.com w Ditc, 30. 2004 10: 34AM PARKS & REC 904-471-6760 No, 1422 P. 2 a� �, ;, FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Beaches and Coastal Systems J�7 FLOR� 3900 Commonwealth Blvd.-MS 300 EExem Number: EXM00300 Tallahassee,FL 32399-3000 (850)488-3180 EXEMPTION DETERMINATION PURSUANT TO SECTION 161.053 or 161.052,F.S. FINDINGS OF PACT AND CONCLUSIONS OF LAW. The request for an exemption was considered by the staff designee of he Secretary of the Department of Environmental Protection and found to be in compliance with requirements of Chapter 62B-33,Flor da Administrative Code (F.A.C.), and 161.053, Florida Statutes. The exemption is specifically limited to the activity in the sta ed location and by the project description given below, attached plans(if any),and any specific remarks attached,pursuant to Paragraph 161.053(12W,Florida Statutes. PROJECT LOCATION: ' PROJECT DESCRIPTION: --LL �] Specific Remarks Attached. Attached Plans: ® Yl 0 NO APPLICANT INFORMATION: I hereby certify that I am either: (1 a)the owner of the subject property or (I b)I have the owner's consent to secure t4is exemption determination on the owner's behalf; and that (2) I shall obtain any applicable licenses or permit ch may be required by federal, state, county, or municipal lav prior to commencement of the exempt activity; (3 owledge th a empt activity is what I requested; and (4) I accept responsibility for compliance with this e i by not exce d a tivity as describgd ab e. /� � H`, -, Applicant's Signature Date %: Telephone No.tri Applicant's Printed Name Address ✓► , � -// _�,r� Complete the following if the applicant is an agent of the p perry owner: / d 4 32 Z Property Owner's Name: PE T-Q o tJl1 �'4 ° e "7L 91.3 Please Print) Address T at—. ( elephoneYNo. EXEMPTION STATUS. The Department has determined that, pursuant to 62B-33.004(3)(d),Florida Administrative Code,the above described proposed project is: ❑ NOT EXEMPT from the permitting requirements of the Department,and a Coastal Construction Control bine (CCCL)permit is required prior to 'initiating work. For a copy of a CCCL permit application form,please contact the Department at the above address. EXEMPT from the permitting requirements of the Department. The exempted work is strictly limited to that described above. DEPARTMENT FINAL ACTION AND FILING AND ACKNOWLEDGMENT: This exemption is authorized on behalf of the Department of Environmental Protection by the undersigned staff designee,and filed on this date,pursuant to section 120.52,F.S.,with the undersigned designated Deputy Clerk,receipt of which is hereby ac I owledged. ..'I l B e 2/3i, y stal Desl:gnee/Depuf Clerk 'Printed Name of Designee/Depury Clerk Date PUBLIC NOTICE 1S ON THE BACK OF THIS PERMIT. POST EXEMPTION DETERMINATION AND PUBLIC NOTICE CONSPICUOUSLY ON THE SITE DEP Form 73-120(5/00) (White Copy-Tallahassee Office] [Yellow Copy-Applicant) [Pink Copy-Staff Designee] Uec. �U. N Rcu 7U'+—'+ll_U /OU IVU. I4LL r, 3 PUBLIC NOTICE The foregoing constitutes final agency action. Any party to this proceeding has the right to request review of this order by the Governor and Cabinet,sitting as the Florida Land and Water Adjudicatory Commission,inaccordance with section 20.255 of the Florida Statutes. To initiate such a review,you must file a request for it,and the request must be received by a member of the Commission or the Secretary of the Commission at The Capitol,Tallahassee,Florida 32399-0001, within twenty days after this order is clerked. You must also serve both the Department of Environmental Protection, Department Clerk, ;900 Commonwealth Boulevard,Mail Station 35, Tallahassee, Florida 32399-3000'and any other person named in this order with a copy of the request within twenty days from the date of.this order. Additionally, any person whose substantial interests are affected by any decision of the Department on the application has the right to request an administrative hearing in accordance with the provisions of section 120.57 of the Florida Statutes. Should you desire an administrative hearing,your request.must comply with the provisions of rule 62-103.155(2)of the Florida Administrative Code, as indicated below. Send requests for hearings to the Department of Environmental Protection, Office of General Counsel, 3900 Commonwealth Boulevard,Mail Station 35, Tallahassee,Florida 32399,3000. The Department must receive the request within fourteen days after your receipt of this notice. When the Department receives an adequate and timely filed request for hearing, the Department will request the assignment of a hearing officer. Likewise,when the Florida land and Adjudicatory Commission receives an adequate and timely petition,the Commission will request the assignment of a hearing officer. Once a hearing officer is requested, the referring agency will take no further action with respect to the proceeding except as a party litigant,as long as the Division of Administrative Hearings has jurisdiction over the formal proceeding. Rule 62-103.155,(2)of the Florida Administrative Code requires that a petition or fequest for hearing contain the following information: (1)The name, address,and telephone number of each petitioner,the applicant's name and address, the Department file number,and the county in which the proposed project would be located; (2)A statement of how and when each petitioner received notice of the Department's action or proposed action; (3)A statement of how each petitioner's substantial interests are affected by the Department's action or proposed action;(4)A statement of the material facts disputed by the petitioner, if any; (5)A statement of facts that the petitioner contends'warrant reversal or modification of the Department's action or proposed action; (6)A.statement of which rules or statutes that the petitioner contends require reversal or modification of the Department's action or proposed action; and(7)A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wants the Department to take. A person may request an extension of time to petition for an administrative hearing. The person filing the request for extension must do so within the time limits'for filing a petition described above and strive all parties with the request.,The request must state why an extension is needed. The Department will grant an`Extension dnly when good cause is shown. If a petition or request for extension of time is filed,further order of the Department becomes necessary to effectuate this notice. Accordingly,the Department's final action may be different from the position taken by it in this notice. Actions undertaken by the permittee under this permit, pending the lapse of time allowed for the filing of such a request for hearing,may be subject to modification, removal, or restoration. Mediation under section 120.573 of the Florida Statutes is not available for this proceeding, Failure to petition within the allowed time frame constitutes waiver of any right that such a person has to.request a hearing under section 120.57 of the Florida Statutes and to participate as a,party to the proceeding. If a legally sufficient petition for hearing is not timely received this notice constitutes final agency action. When this order becomes final, any party to the order has the right to seek judicial review under section 120.57 of the Florida Statutes and rule 9.030(b)(1)(c)and 9.110 of the Florida Rules of Appellate Procedure by filing a notice of appeal with the Department of Environmental Protection,Office of General Counsel,Department Clerk, 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, and with the appropriate district court of appeal within thirty days after this final order is filed with the Department Clerk. The filing fee specified in subsection 35.22(3)of the Florida Statutes must accompany the notice filed with the district court. Any subsequent intervention will be only by the approval of the presiding officer on motion filed under rules 28-5.207 or 60Q-2.010 of the Florida Administrative Code. (New 5/00) CITY OF ATLANTIC BEACH Fora isi BUILDING /ZONING DEPARTMENT L.H' ins 800 SENIINOLE ROAD Dcerr !� �~ ATLANTIC BEACH,FLORIDA 32233-5445 TELEPHONE:(904)247-5800 FAX:(904)247-5845 http://ci.atiantic-beach.fl.us PLAN REVIEW COMNENTS Permit Application# 015 - 9 q 9 6) Property Address: pal q ?�c-,91-02C, � A` r Applicant: (-n QC�rlS C: 1 CNl Project: S This permit a plication has been: proved ❑ Reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed by: �� Date: y `� ✓�' CITY OF ATLANTIC BEACH Ford r y � BUILDING/ZONING DEPARTMENT L.Higgins 1 ) 800 SEMINOLE ROAD S.Doerr ATLANTIC BEACH,FLORIDA 32233-5445 TELEPHONE:(904)247-5800 FAX:(904)247-5845 http://ci.atlantic-beach.fl.us PLAN REVIEW COMMENTS Permit Application# (3 f✓� vl Property Address: Applicant: l.) Project: L �� �� � This permit application has been: R/Approved - w n: c,el'a C- Please re-submit your application when these items have been completed. Reviewed by: L Date: L _ .� w1ming TM JAIL 14 2005 241 Atlantic Blvd., Suite 5 CONSTRUCTION t1 Neptune Beach, FL 32266 BY: tel ■ 904.246.1833 A DESIGN BUILD COMPANY - _ � ��-•' fax ■ 904.247.3147 F L C B 0 0 6 8 3 4 January 13,2005 APPROVED City of Atlantic Beach CITY OF ATLANTIC BEACH Att: Larry Higgins BUILDING OFFICE Building/Zoning Department IJAN 1 2Q�� 800 Seminole Road I Atlantic Beach,Florida 32233 RE:Permit#05-29498 PETRONI DECK EXTENSION By: Mr.Higgins: The following is in response to your PLANS REVIEW COMMENTS on the above referenced permit application- (1) Submit details of design of tie-downs for wind load. Response: The design details,specifically all Simpson wind load tie-downs,joist hangers, thru-bolts and column bases have been added to the attached revised Floor Plait and Elevation (2) List Design Criteria these details are based on. Response: The Design Criteria is asfollows- FLORIDA STATE CODE COMPLIANCE DESIGNED IN ACCORDANCE WITH REQUIREMENTS OF FLORIDA BUILDING CODE 2001. WIND DESIGN PER ASCE 7-98. LOCATED WITHIN WIND BORNE DEBRIS REGION. ALL WORK SHALL BE IN ACCORDANCE WITH SECTION 1606.1.4. OCCUPANCY CLASS: GROUP R3 (RESIDENTIAL) WIND ZONE INFO: WIND-BORNE DEBRIS REGION AS DEFINED BY FBC-120MPH THREE SECOND GUSTS CITY OF ATLANTIC BEACH CODE COMPLIANCE Ordinance Number: 90-01-172 (Adopted:November 26,2001 /Effective Date: January 1,2002,including amendments through Ordinance 90-03-182 adopted May 12,2002) Please att c his lett r to the permit plans. r By s ted, eyw Dow mg • • BASES This product is preferable to similar connectors because of a)easier installation, — - lr b)higher loads,c)lower installed cost,or a combination of these features. MATERIAL:12 gauge base,threaded rod-supl 4T FINISH:Base—Galvanized,Threaded Rod—Z The CBSQ uses Simpson's SDS screws,which allow for fast installation,reduced reveal and high capacity, •, ) while maintaining the net section of the column. w, INSTALLATION:•Secured with epoxy: Drill a�/ I fill the hole with epoxy. Insert the EP84 MATERIAL:See table. FINISH:Galvanized,available in HOG with HOG screws. � N rF To u epoxy •<.' l adjust st after the e ox cures,drilla t INSTALLATION:•Use all specified fasteners.See General Notes. turn the post base up or down to the•Install Simpson's code-recognized SDSst e di '/4x2 wood screws,which are provided with the column base. ry •Supported st a nut:Drilla 3/d'hole e d (Lag screws w111 not achieve the same load.) 5/a-11 NC nut and cut washer on the thi s>' • Post bases do not provide adequate resistance to prevent members from rotating about the base and 3g supplied). Insert EPB44T into the hole therefore are not recommended for non to -su orted installations such as fences or unbraced carports). si p PP ( side , •Embedded in wet concrete:Embed 5/e"1 CODES:See page 10 for Code Listing Key Chart. p cover •Minimum sidecover is 3"from the cenb x ( •Fully engage at least three threads to th Material Dimensions Number of Allowable Loads �, , , n Nominal Uplift i r Model Column Base Strap W� yy2 D H SOS'4 Simpson 2" Avg Uplift Uplift Down ReCodf Post bases ilo rmr lt�nvi!.,id +i i A LL;s y Size (Ga) (GaxWidth) Ult 133 160 100 r from rotalua I ai;u 1r ti 4 1 t Cie Screws ( ) ( ) ( ) ap e o 'e CBSQ-SDS2 0 non tnp mif,14w�i-6„ ". !41 CA CBSO44-SDS2 4x4 12 10 a x 2Y4 39/,e 3'/2 71/15 83/e 14 16667 5335 5335 10975 p° �� ) CODES:See page 10 for Code Listing KB Ch; °b CBSO46 SDS2 4x6 12 10 a x 3 39/,6 55/16 73/4 871/16 14 16667 5335 5335 14420 46 U.S.Patent a r 1 p g 9 Y Q CBSO66 SDS2 6x6 12 10 a x 3 51/2 512 6'/e 83/4 14 24000 5710 6855 14420 4,924,648 + v 1.For higher downloads,solidly pack grout under 1"standoff plate before installing CBSQ into I Model Anchor Uplift Allowa concrete.Base download on column or concrete,according to the code. Typical C8S0 SDS2 Nails Avg Uplift 2.When using structural composite lumber columns,screws must be applied to the wide Installation No. Bolt Ult face of the column. CBO and CBSQ (133) (160) EPB44T 6-16d 5/6 3703 1130 1140 To order with _ CB • • screws,specify CBQ-SDS2 or CBSQ-S02. This product is preferable to similar connectors because of a)easier installation, To order without b)higher loads,c)lower installed cost,or a combination of these features. Screws,specify The CBQ uses Simpson's SDS screws,which allows for fast installation, CBO or CBSQ. I reduced reveal and high capacity,while maintaining the net section of the column. R• f 3_ W MATERIAL:See table. FINISH:Galvanized,available in HOG with HDG screws. The PBS features a 1"standoff height.It n and column ends. INSTALLATION:•Use all specified fasteners.See General Notes. , MATERIAL:PB-12 gauge;PBS—see table. •Install Simpson's code recognized SDS'/4x2 wood screws,which are 2 3"min. FINISH:Galvanized.Some products available provided with the column base. (Lag screws will not achieve the same load.) side m; see Corrosion-Resistance,page 5. •Post bases do not provide adequate resistance to prevent members cover INSTALLATION:•Use all specified fasteners. from rotating about the base and therefore are not recommended for Y •Post bases tiu not i.P 11°° ! ,. non top-supported installations(such as fences or unbraced carports). ¢ 11 from rotatimt about . CODES:See page 10 for Code Listing Key Chart. o I non top-supported intra izl,m ars 6 °: •PB:Holes are provided for installation v Nominal Material Dimensions Number of Uplift Allowable P866 and P866R;all other models use Madel Column Simpson Avg Loads Code ;, sidecover is required to obtain the full I No. Base Strap SDS/.x 2" Uplift Uplift Ref. q Size (Ga) (Ga x Width) W' W2 D H Screws UIt (133) (160) e; +` •PBS:Embed into wet concrete up to thl C8044-SDS2 4x4 7 7 a x 2 39/16 39/16 8 811/16 12 14350 4200 4200 CBQ-SDS2 °:.::, A 2"minimum side cover is required to C8046 SDS2 4x6 7 1 7 a x 2 39/16 57/2 8 811/,6 12 14350 4200 4200 46 of the straps allow for free concrete floe CBQ66 SDS2 6x6 7 7 a x 3 51/2 57/2 8 8'1/16 12 14350 4200 a2Do Typical CBQ SDS2 CODES:See page 10 for Code Listing Key Chi Installation U Cj 1.When using structural composite lumber columns,screws must be applied to the wide face of the column. i o U Dimensions Allowable w Model Uplift 12.16d Nails Ulg (133&160) • , W L o No. UpliftT F, F2 MATERIAL:EPB44A-14 ga.;others-12 ga.base plate,1'/16"OD x 8"pipe o o PB44 39/16 31/4 4267 1365 765 132', FINISH: EPB44A—Galvanized;all others—Simpson gray-paint;see I" -w •$NL� a a PB44R a 37/4 4267 1365 765 132: Corrosion-Resistance,page 5. t N P646 51/2 31/4 4267 1365 765 132E INSTALLATION:•Use all specified fasteners.See General Notes. s rn '�:; H o o P846R 6 31/4 4267 1365 765 132 •Allows 1"to 21/2"clearance above concrete,2"for EPB44A. x` 5 1 L P666 5'/z 5/4 5143 1640 765 132E •Post bases do not provide adequate resistance to prevent membirs T f - PB66R 6 51/4 5143 1640 765 132E a STANDARD• ' Face Mour. � , See Hanger tables on pages 51 to 57. See Hanger Options on pages 158 Dimensions �Sl st Modelfor hanger modificaiions,which may result in reduced loads. GaLU—Value engineered for strength and economy. Precision-formed— e No. w H B engineered for installation ease and design value. ° U—The standard U hanger provides flexibility of joist to header installation. - 1 11 • ` �` g P Y LU24114 19/,6 3/6 /2 4 0 o Versatile fastener selection with tested allowable loads. LUS24 19/16 3'i6 1314 a ® ® HU—Most models have triangle and round holes.To achieve maximum loads, 2x4 U24 19/16 3'/6 1112 a fill both round and triangle holes with common nails.These heavy-duty connectors ; HU26 19/16 3u6 21/4 • v' are designed for schools and other structures requiring additional strength, LUS24-2 18 3Y6 3Y6 2 e, longevity and safety factors. DBL MATERIAL:See tables on pages 51 to 57. 2x4 U24-2 16 3i6 3 2 a 1 / FINISH:Galvanized HU24-2 14 3/e 3/16 2/2 _ LUS26 18 19/16 1 43/4 13/4 4 FOgU241 'WFORLU24 INSTALLATION: •Use all specified fasteners. See General Notes. LU26 20 19/,6 4-Y4 11/2 E U210 HUC412 LU28 •HU—can be installed filling round holes only,or filling round and triangle ` 2x6 U26 16 19/,6 43/4 2 E ConcealedHU26 14 1'3/,6 exceP t holes for maximum values. i 1 3/,6 2/4 Flanges LU Roughs) OPTIONS:•HU hangers available with the header flanges turned in for 25/16'width HUS26 16 15/a 53/6 3 • and larger,with no load reduction-order HUC hanger. LUS26-2 18 3'i6 m •See Hanger Options on page 158,for sloped and/or skewed U/HU models, and HUC(concealed flange)models. DBL U26-2 16 3/6 5 2 f p m HUS26-2 14 3/a 5'/16 by 2 �• •HU only—rough beam sizes available becial order. 2x6 HU26 2 Min 1a 3Y6 53/6 2112 HU MIN NAILING C m ° FILL ROUND HOLES °See page 57 for stocked U hanger rough sizes tables. HU26-2(Max) 14 3'/e 53/6 2'/2 O m HU MAX.NAILING @ Rough sizes are not available in Sx. LUS26-3 18 4% 4Ye 2 V FILL ROUND AND A`. •Also see LUIS and HUS series. TPL U26.3 16 a5/6 4'/4 2 f p m TRIANGLE HOLES 2x6 HU26-3 Min 14 41/16 51/2 21/2 HU26 3 Max 14 4"/,6 5'/2 21/z LUS26 18 19/16 43/4 13/4 - h LU26 20 19/i6 43/4 1'/z f , '' Mbdeicarill�urations , I� LUS28 1s 19/i6 65/6 1314 _f 1'/4+ HUfiB �, inaydifferirom c 2x8 LU28 20 19/16 6% 11/2 t ;those shgWn U26 16 19/16 43/4 2 t MAk .SomPHt/modeiS °" s, HU28 141 19/16 5'/4 21/4 HU214 Typical LU28 dq not have Hus2s 16 15/6 53x6 3 Projection seat on Installation trrangte hotas HUS28 16 15/6 7 3 most models for i6 fsvnsult factory Typical HU ) LUS26-2 18 3116 47 2 maximum bearingand ,Installation It J LUS28-2 18 3/6 7 2 section economy. DBL U26-2 16 3'/6 5 2 2x8 HUS28-2 14 3'/a 73/16 2 DOUBLESHEAR r HU28-2 Min 14 3Y6 7 2' HU28-2 Max 14 3'/e 7 21/2 _ TPL LUS28-3 18 45/a 61/4 2 This product is preferable to similar connectors because of a)easier Installation, 2x8 U26-3 16 45/6 41/4 2 b)higher loads,c)lower Installed cost,or a combination of these features. = LUS28 18 19/16 65/6 13/a LU28 20 19/16 63/6 11/2 See Hanger tables on pages 51 to 57.See Hanger Options on pages • ;_ e�' LUS210 18 19116 713/,6 1314 158 to 162 for hanger modifications,which may result in reduced loads. 2x10 LU210 20 19/16 T3/,6 11/2 1 These hangers have the highest loads of any face mount hangers! v v 6 •.. _' 0 `_ U210 16 19/,6 713/n 2 1 All hangers in this series have double shear nailing.This patented O O a "a a.� U HU210 1a 191,6 7Y6 211. innovation distributes the load through two points on each joist nail for b •• " a i greater strength.It also allows the use of fewer nails,faster installation,anda- o 6 HUS210 16 15/6 s 3 the use of standard nails for all connections.(Do not bend or remove tabs) 0. • ! & LUS28 2 �8 3'16 7 2 MATERIAL:See tables,pages 51 to 57. g :`� ` u. LUS210 2 18 31/6 s 2 o o U210-2 16 31/6 81/2 2 1 FINISH:Galvanized. Some products available in stainlesq steel or Z-MAX; p �- ° DBL HUS210 2 1a 3v6 53/16 2 see Corrosion-Resistance,page 5. ��. ,`h 2x10 INSTALLATION •Use all Specified fasteners.See General Notes. B Z, T 3'/a 813/,6 2/2 p I'-W ,I HUS210 H11210-2 Min 14 1 io 2x HU.SCi R HU210-21Max 14 31/6 8W1 6 21/2 •Nails must be driven at an angle through the joist or truss (HUS26,HUS28, HUS412 I0'4 s Concealed _ I HHUS210 2 1a 35/16 ei6 3 into the header to achieve the table loads. LUS28 and HHUS similar) .K, 4_;,.,. 4 1—,•,.,...4-,_; Flanges _ �IS9R-a iR 456 sv4 2 Face Mount Hangers - Solid Sawn Lumber (DF & SP) DimensionsFastenersJois9 " x1oOQ FIP latah/S�ittligrlge Alt W afa(q�tl� `r F 1>t t�)ieif code Dbfun Size Model l3a W H B Header Joist �pllfS slonr iOQ � Ovl°Oytd k �F{>6f(f2b t`ojnd4�iF Ref. 10d I 16d aw��1yat' �1btl) �1iO11 96(4, LDd +, 9ds�bil;t[ mlett,; 2`iD1 ` SAWN LUMBER SIZES LUS210 18 1a/,e 7121,6 1aI1 8-1 Od - 4-10d „� 5GT, t .;.t r14Cir?ifz T" " i1¢ (69 „;�i:dtKtl49 4,37,87,140 `t LU210 20 19/1e 713he 11/2 10-10d 10-16d 6•1Odx1'/2 � },,S 7 9l j186 �d 2,40 2x12 U210 16 19/,e 713/,6 2 10-10d 10-16d 8-10dx1'/2 HU212 14 19ha 9 2114 - 10-16d 610dx1Y2 (.866>, k1Q4'Q•;�--'+ 1tfr7$ 26,83 HUS210 16 1% 9 3 - 30-16d 10-16d r, Q`33 '28'8 3 `. 4,37 LUS210-2 1S 3'/a 9 2 - 8.16d 6.16d 10906 1550 1550 - 1765 - 2030 - 2210 Lowest 1,84 U210-2 16 3Ye 81/2 2 14-10d 14-16d 6.1 Od 11000 890 1065 1555 1860 1785 2140 1940 2330 +40% 26,83 LUS214.2_ 18 3'/s 1 OW, 2 - 10.16d 6-16d 12750 1550 1550 2030 - 2335 - 2540 +56% x12 HUS210-2 14 3'/e 93/ie 2 - 8.16d S-1 6d 14550 2050 2590 - 201'0 - 2310 2510 +136% 1,84 HUS212.2 14 3'/s 103/. 2 - 10-16d 10-16d 1803_3 2580 3240 - 25_1_0 - 2885 - 3140 +156% HU212.2(Min) 14 3Ya 109/,e 21/2 - 16.16d 6.1 Od 14316 905 1085 - 2145 - 2465 - 2680 +387% 26,83 HU212-2(Max) 14 31/a 109/,a 2112 - 22-16d 10.10d 15933 1505 1810 - 2950 - 3390 - 3685 +411% LUS28.3 18 4% 614 2 - 6-16d 4.16d U t +7"d[1Ea W 125 446 X58 r: `^ nn LUS210-3 18 45/e 83/+6 2 - 8-16d 6.16da6;�! x �65Qi eG �M�`�f 3 398/1 221 °{y 9 C TPL HU212 3{Min) i4 4"/,e 105/,e 21/2 - 16-16d 6•1Od 7A3a� �CfS',� i ` R1 t *r! •., 2x't 2 s l 4 s m + k V HU212.3(Max) 14 4 /ie 10/16 2/2 - 22-16d 10-10d 1593 D5 t8 1 wrt•ep 2�ar + a 90>I 3358x, .Z 26,83 C U210-3 16 45/4 73/4 2 14-1 Od 14.16d 6-10d t1�Q 1G1 G69F?' r9Qf`x ,4f E&,189(? l78$<'?"�14Q 9.941} iZ3'0"< `p LU5210 18 19/1a 713/,a 13/4 8-1 Od - 4-10d 7750 930 1115 1275 - 1470 - 1595 - Lowest 4,37,87,140 LU210 20 19/,a 7i3/ia 13/4 10.10d 10-16d 6.1Odx11/2 6233 735 850 1110 1330 1275 1530 1390 1660 +11% 2,40 2x14 U210 16 19/,6 71-Yie 2 10-10d 10.16d 6.10dx1'12 5563 720 865 1110 1330 1275 1530 1390 1660 +53% y HU214 14 19/,6 10'/e 2114 - 12-16d 6•10dx1'/z 11383 720 865 - 1610 - 1850 - 2010 +88% 26,83 U214 16 19/is 10 2 12-10d 12-16d 8.10dx11/2 5583 960 1150 1330 1595 1530 1835 1665 1995 +147°f y U210-2 16 3'/a BYi 2 14.10d 14.16d 6-1 Od ;996 10A x89. '.1 i �i a1 9 a 188 + 95i'.I"14�1 1 ' ptt$ 9A` LU1214.2 18 3'/e 1015/is 2 - 10-16d 6.16d f s 31F 1,84 HUS212 2 14 3/e 10/4 2 - 10.16d 10.16d } ET33.', �dt3 ddQy DBL HU212 2(Min) 14 3Ye 109/ie 2'/2 - 16-16d 6.1 Od C1G9.$' � 086 ,21d5 b 65 ` 680 'SAB°la". - 2X14 e 6 btu NU212-2(Max) 14 3/a 1 O/i6 2/z 22.16d 1,0„t Od X150'1 1''SQ ,18,•0 l �w+ 295; $99 3686;:3�h 285%rL HU214-2(Min 14 3Ye 1215/,6 2Yz - 18.16d 8-tOd 1'6ib' 1245 „�9.b6 „ 1:Q " L . 75 r' kr� 80161 1#269wud HU214-2(Max) 14 31/a 1213/,6 2'/z - 24•16d 12-10d U210-3 16 45/e 73/4 2 14.10d 14.16d 6-1 Od 11000 890 1065 1555 1860 1785 2140 1940 2330 _ TPL HU214-3(Min) 14 411/16 121/1a 21/2 - 18.16d S-10d 15166 1205 1445 - 2410 - 2775 - 3015 26,83 2x14 - - HU214.3(Max) 14 411/it 12'ha 21/2 - 24-16d 12-10d 18196 1810 2170 - 3215 - 3700 - 4020 U214 16 19/16 10 2 12-1 Od 12.16d 8-10dx1'/2 g ' 8 68p, �f l :.;1' 39. 1"5:95 „1 w1` ;18312` ;6 ffii 6^;LpWeSN,z 2x16 HU214 14 19J1a 10'/s 21/4 - 12-16d 6-1Odx1Y2 13 +y20 88', d 81D 9 ";98SQ` 20jQ' t18(Y%;; NU216 14 19/,e 1215/16 2'!. - 18.16d 8-10dx11/z 1;1383_r �i 1189 ti + '2dti0r %7$ Y "3018'x1wT'30" ) HUS212-2 14 3'/s 103/4 2 - 10.16d 10.16d 18033 2700 3240 - 2510 - 2885 - 3140 Lowest 1,84 1 HU216.2(Min) 14 3Ye 137/5 2'/2 - 20.16d 8-10d 15933 1205 1445 ----2680. - 3080 - 3350 +111% HU216-2(Max) 14 3'/e 13716 2'/2 - 26.16d 12.10d 18196 1810 2015 3485 4005 - 4355 +120% TPL HU216.3(Min) 14 4t1/4 137/a 21/2 - 20.16d 8.10d 9 Q 0.2b A�tS +2%x26✓. - . BO8 c 1-J^13350. Lr �� f „ 7 �18,1'�1j?� T5 34 S..,k-, '4Q0$ ,' 4655;» "+ <.;"TM 2x16 HU216.3(Maxj 14 4 /,6 13/s 2/2 - 26•l6d 12.1Dd �. '), .,, 26,83 z U34 16 29/15 33/6 2 4-1 Od 4-16d 2-1Odx11h 4117 240 265 445 530 510 610 555 665 o 3x4 HU34 14 29/+e 3�Va 21/2 - 4.16d 2.10dx1Yz 5270 240 290 - 535 - 615 - 670 w U36 16 291,6 53/a 2 8-10d 8.16d 4-1Odx1'h 3x6 LUS36 18 29/+e 51/4 2 4.16d 4-16d .S:T, 11:40 18�+", � X100011^ 1'90 {rig j2v60t9 i =" 160 HU36_ 14 29/la 53/a 21/2 - 8-1 6d 4-10dx1'/z x3474.. 5(? d 3,.r -1(17;0, ''y1235. 1 L13.4'.9 ,>" ;•j o U36 16 29/,e 53/6 _2 8-10d 8.16d 4.10dx11/2 7033 480 575 890 1065 1020 1225 1110 1330 d 3x8 HU38 14 29/,a 7Ye 2'/z - TO.t6d 4•10dx11/2 11383 480 575 - 1340 - 1540 - 1675 26,83 0310 16 Z9J1e 87/6 2 14-10d 14.16d 6-10dx1'/z 330, Xtra " 8 1 jQQQ2d, ash t5 7;3afl � 6 ,21 3 .:.:. N 3x10 LUS310 18 29/+e 7'h 2 - 6-16d 4-16d 160 a 7:59G�. HU310 14 29ha 87/5 2'/2 - 14-16d 6-10dx1'J2 g66� U310 16 29/16 87/6 2 14-10d 14.16d 6-10dx1'/2 11000 720 865 1555 1860 1785 2140 1940 2330 3x12 - HU312 14 29/ie 165/6 2Yz - 16-16d 6-10dx11/2 14316 720 865 - 2145 - 2465 - 26808 U314 16 29/,5 101/2 2 16-10d 16-16d 6.10dx11/2 1j00 ,y2'0 86 „`i 775 21,' 11 2fl4fFf 845:'s.822.,rM 26,83 cS 3x14 HU314 14 29he 123/6 21/2 - 18-16d 8-10dx1Vz 31,88 ws5^ �5 (9rts w 2x870 A 0314 16 29/-. 10112 2 16-10d 16-16d 6-10dx1Yz -11000 720 865 1775 2130 2040 2445 2220 2660 ' 3x16 HU316 14 2-/,.T14`/`- 21/2 - 20.16d 8-1Odx11/2 15933 960 1150 - 2680 - 3080 - 3350 A..:. 4, +L is X: 4 ..... LUS44 18 39/16 3 2 - 4.16d 2.16d .630;3. 44t9�� .+, 46?.. „�6G,.. ..• 880:�.'�.. _.r- 960 �L \N®5t'.` 1,84 4x4 U44 16 39/ie 271a 2 4-1Od 4-16d 2.10d 4.19"( x'35 ` 55 "2} 5 530 r 61fl:* 8Tr0` ''565 686 'x'i�Q°Fe r 2- 26,83 HU44 14 39/ie 27/e 2'/z - 4.16d 2-lOd_ LUS46 18 39/+e 43/4 2 - 4.16d 4.16d_ 6076 1140 1160 - 1000 - 1150 - 1250 Lowest 1,84 U46 16 39/ie 47/5 2 8.10d 8.16d 4.10d 7033 590 710 890 1065 1020 1225 1110 1330 +37% 26,83 46 HUS46 14 39/le 5 2 4-16d 4-16d 8033 1080 1235 - 1005 - 1155 - 1255 +152% 1,84 HU46(Min) 14 39/16 53he 21/2 - 8�6d4-10d 9474 605 725 - 1070 1235 - 6,83 HU46(Max) 14 39/+e 53/,6 2'/z - 12 -10d 11383 905 1085 - 1610 - 1850 - 2010 +185% 52 See footnotes on opposite page. CODES:See page 10 for Code Listing Key Chari. DRc. 30. 2004 10: 34AM PARKS & REC 904-471-664 tNo. 1422 P. 2 JAN 14 p;;(11 a t , FLORIDA DEPARTMENT OF ENVIRONMENT PROTECTION Office of Beaches and Coastal Systems EX1 00300 o FIOR A Exem Number: 3900 Commonwealth Blvd.-MS 300 : Tallahassee, - FL 32399-3000 -- (850)488-3180 EXEMPTION DETERMINATION PURSUANT TO SECTION 161.053 or 161.052,F.S. FINDINGS OF FACT AND CONCLUSIONS OF LAW: The request for an exemption was considered by the staff designee of the Secretary of the Department of Environmental Protection and found to be in compliance with requirements of Chapter 62B-33,Florida Administrative Code (F.A.C.), and 161.053, Florida Statutes. The exemption is spedifically limited to the activity in the stated location and by the project description given below,attached plans(if any),and any.specific remarks attached,pursuant to Paragraph 161.05302)(c),Florida Statutes, PROJECT LOCATION: ' /y)' Igo-- /0a �s� PROJECT DESCRIPTION: t , (] Specific Remarks Attached. Attached Plans: ®Ws M NO APPLICANT INFORMATION: I hereby certify that I tarn either: (I a)the owner of the subject property or (lb)I have the owner's consent to secure 4s exemption determination on the owner's behalf, and that (2) I shall obtain any applicable licenses or permi ch may be required by federal, state, county, or municipal law prior to commencement of the exempt activity; (3 owlWpoperty activity is what I requested; and (4) I accept responsibility for compliance with this a by noty as describgd ab e. A licant's Si afore PP 8n ate TelephoneNoApplicant's Printed NamedreComplctethe following if the applicant is an ag : �'L% x-41• r3 cl-- 32 z 3 3 Property Owner's Name: �E T2o rj GES v-2 e�d a,y.. V ~1 a tie.c�cl,. 1 ..t 4G u y )may!_ r�3 (Ple a Print) Address Telephone No. EXEMPTION STATUS. The Department has determined that,pursuant to 62B-33.004(3)(d),Florida Administrative Code,the above described proposed project is: 0 NOT EXEMPT from the permitting requirements of the Department,and a Coastal Construction Control Line (CCCL)permit is required prior to initiating work. For a copy of a CCCL permit application form,please contact the Department at the above address. EXEMPT from the permitting requirements of the Department. The exempted work is strictly limited to that described above. DEPARTMENT FINAL ACTION AND FILING AND ACKNOWLEDGMENT: This exemption is authorized on behalf of the Department of Environmental Protection by the undersigned staff designee,and filed on this data,pursuant to section 120.52,F.S.,with the undersigned designated Deputy Clerk,receipt of which is hereby ac' owledged. SMOP DesigneelDepary Clerk Printed Name of DerigneelDepwy cle;;k Date PUBLIC NOTICE 1S ON THE BACK OF THIS PERMIT. POST EXEMPTION DETERMINATION AND PUBLIC NOTICE CONSPICUOUSLY ON THE SITE DEP Form 73-120(5100) [White Copy-Tallahassee Office] (Yellow Copy-Applicant) [Pink Copy-Staff Designee] uec. )u. [uu4 Iu; 34r+ivi rhRNO a nc�, yu4_4r i-Qiou iuo. 14ZL r. PUBLIC NOTICE The foregoing constitutes final agency action. Any party to this proceeding has the right to request review of this order by the Governor and Cabinet,sitting as the Florida Land and Water Adjudicatory Commission,in accordance with section 20.255 of the Florida Statutes. To initiate such a review,you must file a request for it,and the request must be received by a member of the Commission or the Secretary of the Commission at The Capitol,Tallahassee,Florida 32399-0001, within twenty days after this order is clerked. You must also serve both the Department of Environmental Protection, Department Clerk,3900 Commonwealth Boulevard,Mail Station 35, Tallahassee,Florida 32399-3000,and any other person named in this order with a copy of the request within twenty days from the date of this order. Additionally, any person whose substantial interests are affected by any decision of the Department on the application has the right to request an administrative hearing in accordance with the provisions of section 120.57 of the Florida Statutes. Should you desire an administrative hearing,your request must comply with the provisions of rule 62-103.155(2) of the Florida Administrative Code,as indicated below. Send requests.for hearings to the Department of Environmental Protection,Office of General Counsel,3900 Commonwealth Boulevard,Mail Station 35,Tallahassee,Florida 32399-3000. The Department must receive the request within fourteen days after your receipt of this notice. When the Department receives an adequate and timely filed request for hearing, the Department will request the assignment of a hearing officer. Likewise,when the Florida Land and Adjudicatory Commission receives an adequate and timely petition,the Commission will request the assignment of a hearing officer. Once a heariiig officer is requested, the referring agency will take no further action with respect to the proceeding except as a party litigant,as long as the Division of Administrative Hearings has jurisdiction over the formal proceeding, Rule 62-103.155.(2)of the Florida Administrative Code requires that a petition or tequest for hearing contain the following information: (1)The name, address,and telephone number of each petitioner,the applicant's name and address, the Department file number,and the county in which the proposed project would be located; (2)A statement of how a:nd when each petitioner received notice of the Department's action or proposed action; (3)A statement of how each petitioner's substantial interests are affected.by the Department's action or proposed action;(4)A statement of the material facts disputed by the petitioner, if any; (5)A-statementof facts that the petitioner contends'warrant reversal or modification of the Department's action or proposed action; (6)A.statement of which rules or statutes that the petitioner contends require reversal or modification of the Department's action or proposed action;and(7)A statement of the relief sought by the petitioner,stating precisely the action that the petitioner wants the Department to take. A person may request an extension of time to petition for an administrative hearing. The person filing the request for extension must do so within the time limits'for filing a petition described above and seine all parties with the request.,The request must state why an extension is needed. The Departnent will grant an'e?dension only when good cause is shown. If a petition or request for extension of time is filed,further order of the Department becomes necessary to effectuate this notice. Accordingly,the Department's final action may be different from the position taken by it in this notice. Actions undertaken by the permittee under this permit, pending the lapse of time allowed for the filing of such a request for hearing,may be subject to modification, removal, or restoration. Mediation under section 120.573 of the Florida Statutes is not available for this proceeding. Failure to petition within the allowed time frame constitutes waiver of any right that such a person has to.request a hearing under section 120.57 of the Florida Statutes and to participate as a party to the proceeding. If a legally sufficient petition for hearing is not timely received this notice constitutes final agency action. When this order becomes final,any party to the order has the right to seek judicial review under section 120.57 of the Florida Statutes and rule 9.030(b)(1)(c)and 9.110 of the Florida Rules of Appellate Procedure by filing a notice of appeal with the Department of Environmental Protection,Office of General Counsel,Department Clerk, 3900 Commonwealth Boulevard, Mail Station 35,Tallahassee, Florida 32399-3000,and with the appropriate district court of appeal within thirty days after this final order is filed with the Department Clerk. The filing fee specified in subsection 35.22(3)of the Florida Statutes must accompany the notice filed with the district court. Any subsequent intervention will be only by the approval of the presiding officer on motion filed under rules 28-5.207 or 60Q-2.010 of the Florida Administrative Code. (New 5100) i --a tl � --55:5�t LT X// ECK EXTENSION I 4114-I i - .�I i-";, ♦)1 t fl 1 i r i1 r ),f-: "• FFFF'"' ]!F 1 ' +'ttty ri ii prE jf ' �rt � 1L�rl ,# �±� i.lrrl I �� # ' ��� t � c 17F �� •�t j 1 ��.r/ � .. is i,f1. t - .t i i� ; i r[: ri(ill.y F , � 7; .� >, t { � ► .,rl�;, !}'t�.t t }it I+ ' .`' f�Fj � �'t`.-tli l _ 1. rlT7i r -t i � r � ... f ,: ENSItidy . . ,. l% - i City of Atlantic Beach i Planning and Zoning Department APPROVED I J This approval verifies compliance withppiicabte CITY OF ATLANTIC BEACH O zoning, subdivisi and other to a! land BUILDING OFFICE j development regui ions, but does not constitute n approval for the iss ance of permits. Cpmpliance N 1 J 2005with Florida Building ode and all other applicable JA ; local, State and Fede I permitting requirements ! must be verified by sign ure of the City pfAtlantic Beach Building-Official p ' 10 the issuance of a ( I Building Permit. By: I Approved By: C op ommunity ve men - — - - - 1' ----------— —r ..---- Date: DI-i ai-OZ/ 7s...._ 6. Jam' v. 10 0 • 1 z / p �f'#a! '3Q 4C *3$ `5s> !' ,-l•"` ~,A.•-�.ate -z�.-�r.� r• ' 8 f j ` Irt i ------------------------ fill _ I + � r , S .1: ! a .'+j it ; "t S 33f +t},� '� + �� ` ♦ //� � �[� } t j .y �h�—s2,�h��► Y,. t _ � �yr � Pit etlt+ l� � trjf I T 1 ! I "`''` --Mz✓ �.C9 y -' PETE DOWLING PRINCIPAL mwhnaTM g "Ry CONSTRUCTION %J 241 Atlantic Blvd.,Suite 5 A DESIGN BUILD COMPANY Neptune Beach,FL 32266 tel ■ 904.246.1833 fax ■ 904.247.3147 n♦torInwlinoamindsorine.com cell■ 904.219.8044 '01$ 4. . i 1 « PETE DOWLING Y- PRINCIPAL W� inaTIM !CONSTRUCTION %J 241 Atlantic Blvd.,Suite S A DESIGN BUILD COMPANY Neptune Beach,FL 32266 Fl CB 006834 tel ■904.246.1833 fax ■904.247.3147 petedowling@mindspring.com cell■ 904.219.8044 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD J �•� ATLANTIC BEACH, FLORIDA 32233 x ` INSPECTION PHONE LINE 247-5826 �J�31 Application Number . . . . . 04-00028394 Date 5/27/04 Property Address . . . . . . 1879 BEACH AVE Tenant nbr, name . . . . . . REPL AIR HANDLER Application description . . . MECHANICAL ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ PETRONI , GERARD OCEAN STATE HEAT & AIR 1879 BEACH AVENUE 1476 ATLANTIC BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 249-8251 --------- --------- ---------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 55 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 55 . 00 55 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 55 . 00 55 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CO: BUILDING OFFICIAL CITY OF ATLANTIC BEACH MECHANICAL PERMIT APPLICATION ti Date. Property Address: i me e�)ea.ai QAI�t I- Owner: Telephone #:ZQ3 Contractor: ace �-TQne 4 2 `_��� Telephone #: Contractor Address: 14-7(p OiWflu l" MCC] n _ Fax#: In consideration of permit given for doing the work as described in the above statement,we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinances and standards of aood practice listed therein. Type of Heating Fuel: If other construction is being done on this building or site,list the building permit number: Electric ��,• Gas: _LP _Natural _Central Utility ❑ Oil ❑ Other–Specify MECHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK Heat _Space _Recessed Central —Floor Residential �► Air Conditioning: _Room Central ❑ Duct System: Material Thickness ❑ Commercial Maximum capacity cfin ❑ Refrigeration ❑ New Building ❑ Cooling Tower: Capacity gpm Existing Building ❑ Fire Sprinklers:Number of Heads ❑ Elevator: _ Manlift Escalator (Number) Replacement of Existing System ❑ Gasoline Pumps (Number) ❑ Tanks (Number) ❑ New Installation ❑ LPG Containers (Number) (No system previously installed) ❑ Unfired Pressure Vessel ❑ Extension or Add-on to Existing System ❑ Boilers ❑ Gas Piping ❑ Other-Specify ❑ Other—Specify LIST ALL EQUIPMENT AIR CONDITIONING,REFRIGERATION EQUIPMENT&CONDENSOR'S Approving Number Units Description Model# Manufacturer Ton's Agency BEATING—FURNACES,BOILERS,FIREPLACES&AIR HANDLER'S Approving Number Units nDescription Model# Manufacturer BTU's Agency (� ^ TANKS Nominal Capacity Type Liquid Serial Approving How Many &Dimensions Contained Manufacturer No. Agency 800 Seminole Road •Atlantic Beach, Florida 32233-5445 Phone: (904)247-5800• Fax: (904)247-5845 • http://www.ci.atlantic-beach.fl.us CITY OFATLANTIC BEACH 800 SEMINOLE ROAD f} ATLANTIC BEACH,FLORIDA 32233-5445 stl TELEPHONE:(904)247-5800 FAX:(904)247-5805 S1 SUNCOM:852-5800 http://ci.atlantic-beach.R.us Ir 1 �� Monday,November 04, 2002 Eric Petroni 1879 Beach Ave. Atlantic Beach, Fl. Dear Sir, This letter is in responce to your inquiry as to the requirements co nc tion of a enclosed stairway on the east side of the garage apartment at The stairway will have to be constructed to comply with the City of Atlantic Beach codes and ordinances including the Fla. Building Code. The proposed stairway is encroaching into the Coastal Construction zone and will have to comply with Florida Department of Environmental Protection(DEP) guide lines for construction in the zone. Please contact Bobbie Nelson at the DEP for help in the design of this structure. She can be reached at 850-487-4475. Please contact me at 247-5826 or by e-mail at dford@ci.atlantic-beach.fl.us if you have any questions. Sincerely, Z, Q- 7-"(� Don C. Ford CBO Building Official Cc: Cit Manager zor silo NOUN AS RE LOcK �.7 CERT/F/ GIRDED /N p eQ ' �r ' EY ED �-p�, LAT gppK p .Q S110 OP OW ACES - _ N J� OF 57k (� ,e- .s/ r O� TyE- pUSki T RECpRDs ✓ OR ,y of -f-- 7, .4Y�U�qL NOUN/..), 0,4 F''"_— t 0 GE' R C � a b �L ZO 9 a i h o r- • 4 J�i d , [ f r�1 , cCo O f 2 9 4• o a 81.'1O 01 ..� I►- 4• � Dep, \ 1.�+. s t'44� \ r• t t9 2 t• \\` 71 ` " `+� l ` 5'� , ��:• oA GOQ6T.4G. G'p�lsTt'UGTId� — Co,vr�eo� L/�1E' �aG4Trv.,✓' (1'EE -3829 4v 17 co t �`'s. y Via. �` ��t' �'� S7 r`t i I'Z•S �\ RAVIj&A CEPttFICA T1pNS. ,.. {�'EEYAL UAT6'F!G't>v d'vtlE Cll11�': JI 2S'Fz � <,' ,.-IW. IAo E-46V. Of 4Zc & G'E`f 104r,5 !c1•d 9Z' Z NOT VALID UNLESS EMBOSSED WITH SEAL OF THE UNDERSIGNED. THE PROPERTY SHOWN HEREON APPEARS TO LIE WITHIN FLOOD HAZARD ZONE 1/€ AS SCALED FROM FLOOD INSURANCE RATE MAP vaot FOR A7'c4Arr/c 8E'ACI4., FLORIDA, DATED 4-17-8.2 7'RI-SfiAT.E LAND SU.F V.EYORS, INC. 8411 8A YMEADOWS WAY SUITE #2, JAOKSONWLLE, FLORIDA 32256 (944) 731--7235 LEGEND THIS SURVEY DOES NOT REFLECT OR DETERMINE OWNERSHIP. a CONG SON # IRON COQ THE FLOOD ZONE DATA DENOTED HEREON IS SHOWN AS A COURTESY ONLY AND DQES NOT (SET WIN CAP #LS 4144) CONSTITUTE A CER.77RCATION OF THE SAME. -X-FENCE 0 IRON COR,(FOUND) ig cROss CUT aR.L. BUILDING RESTRICTION UNE MW7 EASEMENT LARRY G. EDDY, P.L.S.. No. 4144 '/w MOOT-OF-WAY SCALE. /„= ,� 715. COMWD AREA CENTERLINE - z , 4wmde C AIR CMD1770MIVG PAD ilEGIST SUR VE R, STA TF OF FLORIDA q RADIAL DISTANCE DATE: 1/ 7`"9z r CONCRETE 49 _PG. 1.3 FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Beaches and Coastal Systems 1 3900 Commonwealth Blvd.-MS 300 Perndt Number. 913 45 FLORfDA Tallahassee,FL 32399-3000 �. (850)488-3180 No. of Pages Attached.• FIELD PERMIT PURSUANT TO SECTION 161.053 or 161.052,FLORIDA STATUTES FINDINGS OF FACT AND CONCLUSIONS OF LAW: The request for a permit was considered by the staff designee of the Secretary of the Department of Environmental Protection and found to be in compliance with requirements of Chapter 6213-33, Florida Administrative Code (F.A.C.). Approval is specifically limited to the activity in the stated location and by the project description, approved plans (if any), attached standard conditions, and any special conditions stated below pursuant to Paragraph 161.053(5),Florida Statutes. This permit may be suspended or revoked in accordance with Section 62-4.100,F.A.C. PROJECT LOCATION: /r`I C 14 k' d U F PROJECT DESCRIPTION: + {-� r �. yf f_.6 1.A) ✓ 4;/ t� l `_..5 a 4, SPECIAL PERMIT CONDITIONS: This permit is valid only after all applicable federal, state, and local permits are obtained and does not authorize contravention of local setback requirements or zoning or building codes. This permit and public notice shall be posted on the site immediately upon issuance and shall remain posted along with local approval until the completion of any activity authorized by this permit. Other special conditions of this permit include: a F.� •.! �•�„? �'„ �> -,"` tJ l" .A;.! Pe 9 ✓!e Yk�,.a^"J" ,'v ry f-., N STANDARD PERMIT CONDITIONS: The permittee shall comply with the attached standard field permit conditions. APPLICANT INFORMATION: I hereby certify that I am either: (1 a)the owner of the subject property o ' (1 b) have the owner's consent to secure this permit on the owner's behalf, and that (2) I shall obtain any applicable licenses or permits whk y be required by federal, state, county,or municipal law prior to commencemenyof`theauthorized work; (3)I acknowledge that the authorized work is what I requested;and(4)I accept responsibility for corn ',OW-V rthall ppprrtniit con ` �^ T Date " )M y r�, ,•"° o v.. . Applicant's Sigrfature ""' 'elephone No..(' X Applicant's Printed Name c� M' !� . . Address If applicant is an agent: printed name of property owner property owner's address property owner's telephone no. DEPARTMENT FINAL ACTION AND FILING AND ACKNOWLEDGMENT: This field permit is approved on behalf of the Department of Environmental Protection by the undersigned staff designee,and filed on this date,pursuant to section 120.52,F.S.,with the undersigned designated Deputy Clerk,receipt of which is hereby acknowledged. /f} -.a.• -Jd, I ...,,' -.,y�,,,,gJ r `y / ++..+♦ l 6 Y_! Staff DesigneelDepury Clerk Printed Name of DesigneelDeputy Clerk � D9te - PUBLIC NOTICE IS ON THE BACK OF THIS PERMIT. EXPIRATION DATE: /;' (Emergency permits issued pursuant to Section 6213-33.014,F.A.C.,are valid for no more than ninety days and other field ptrrnitslare valid for no more than 12 months. The staff designee may specify a shorter time limit.) EMERGENCY PERMIT: ❑YES NO Approved plans are attached: YES ❑NO POST PERMIT AND PUBLIC NOTICE CONSPICUOUSLY O THE SITE DEP Form 73-122(Rev.8/98) [White Copy-Tallahassee Office] [Yellow Copy-Applicant] [Pink Copy-Staff Designee] 1491 Atlantic Blvd. Neptune Beach, FL 32266 Befireen Lung fobn Silvers (?Auto Zone on Atlantic Mcd.. M , T (East of the Intracoastal Matencay) 1 Tek (904)241-7652 �3/�e�,,,,<<se,�;re,9,�c. FAX. 241-2029 -72 21 C GRAPHIC DESIGN • FREE PICK UP& DELIVERY DIGITAL COLOR OUTPUT FROM MAC& PC•COMPLETE BLUEPRINT SERVICE ONE TO FOUR COLOR PROCESS PRINTING a � P�LANr'i' v S FlORipP OF ADDITIONS or • - - • D• NOT REMOVE JOB ADDRESS DATE THIS JOB HAS NOT BEEN COMPLETED The following additions or corrections shall be made before the job will be accepted f-S C o N1f E c( -A& r cn m mdya c c F-5-S //3(f= 'r 4.1yN D </Z. MOU QS _- (_ S f-F TO Qg OF f� A tc S-Y? $15.00 REINSPECT FEE it is unlawful for any Carpenter, Contractor, Builder,of other persons, to cover or cause to be covered, any pa he work with flooring, lath, earth or other material, until the l roper inspector has had ample time of approve the After additions or corrections have been PLUMBING yJ` made, call 247-5826, Building Depart- ,o��a ment for an inspection. Field Inspectors ELEC are in the office from 8;00 a.m. to 5:00 BL gh Friday. p.m. Monday throu J� MAI-' ZWlU Wl-tV(x 1xUU1V1J44J-CY Z) U.M !/L`' r UP LOT 43 BLOCK "w" AS SHOWN ON MAP OF 4i6OierM DTLe.VT/G BED g -- I./A//T- �.A Z R-[ -R-S' CORpD�a�"�e�✓ AS RECORDED IN PLAT BOOK /6_PAGES 5-7 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA CERTIFIED FOR: C ERG R D ,QE/O!/N�✓ PET.¢en// . /I/ORI,tiES 7" /�IO�Z T G�4��' /NC. •__ __ 1�Jw nFFi cE" 6� �E/TN�„�,4TSe.✓,• �'/.HJT dMEdoiC,d.✓ T/TGE/N1'l�iP,G^/GE G'o . lie 41 0 � o L P4 � �O \ 9 �o \.t�,� �,� � vim•. �ti•L q 9 0. � � o o q � SL ct� � o oo . ow a �o 0 a FoR CoasTAL Co-/JTRUer/D•✓ \%°5 COAlr"Oc- 61^16- 60C47-10^1— LIFE 'g 1, �� 46 ; ` ti t• �o�vc Qoi Q R N,��� f '�O0-1 G`Ol OE NG 1� 200 � o 98VIS-0b CEPT/FICA7'1&V&: 5-ZSLf3 A'E'4/sip ro svow,vEwsrET.s, /t/-92 ,?EEYAL DATE Fl00o LONE L/tiE: //ZS'92 /N• LA? EGEL. tr FLooO L'E,c�T f/C.QTE W9Z" L II' -9 2 NOT VALID UNLESS EMBOSSED WITH SEAL OF 7HE UNDERSIGNED. THE PROPERTY SHOWN HEREON APPEARS TO LIE WITHIN FLOOD HAZARD ZONE X i/E AS SCALED FROM FLOOD INSURANCE RATE MAP odrit FOR ATcawric BE•vcAl) FLORIDA, DATED TRI-STATE' LAND SURVEYORS, INC. 8411 BA YMEADOWS WAY SUITE #2, JACKSONVILLE, FLORIDA 32256 (904) 731-7235 LEGEND I HEREBY CERTIFY 7HA T THE ABOVE LANDS WERE SURVEYED UNDER MY ■ CONC. MON RESPONSIBILE SUPERVISION AND DIRECTION, 77-IAT THERE ARE NO • IRON COR. ENCROACHMENTS EXCEPT AS SHOWN AND 77-IAT THE SURVEY SHOWN (SET W7H CAP i LS 4144) HEREON MEE7S 7HE MINIMUM TECHNICAL STANDARDS SET FORTH BY -x- FENCE 77-IE FLORIDA BOARD OF LAND SURVEYORS PURSUANT TO SECTION O IRON COR. (FOUND) 472.027, FLORIDA STA TU T FS 0 CROSS CUT BR.L. BUILDING RES7RIC7/0N UNE e ESM•r EASEMENT LARRY G. EDDY, P.L.S. No. 4144 RI V RIGHT-OF-WAY COV. COMMi AREA SCALE.• € CMXRUNE A/C AIR CONDI770NING PAD EGIS T&K SUR VE R, STA TF OF FLORIDA (R) RADIAL DISTANCE DATE: /I- 7-9 z Q CONCREX --777 — CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 SEMINOLE ROAD-ATLANTIC BEACH,FL 32233-TEL: 247-5826-FAX: 247-5877 Permit Number: 20073 Address: 1879 BEACH AVENUE Permit Type: FENCE ATLANTIC BEACH, FLORIDA 32233 Class of Work: NEW Township: 0 Range: 0 Book: Proposed Use: Lot(s): 43 Block: Section:0 Square Feet: Subdivision: NORTH ATLANTIC BEACH Est Value: Parcel Number: Improv. Cost: 2,636.00 Date Issued: 5/15/2000 Name: GERARD & REIDUNN PETRONI Total Fees: 10.00 Address: 1879 BEACH AVENUE Amount Paid: 10.QQ <. ATLANTIC BEACH, FLORIDA 32233 Date Paid: 5/15/20Q ==' Phone: (904)241-6913 Work Desc: CONST , AL INUM FENCE P R PLANS PROPERTY OWNER PERMIT 10.00 P:r NOTICE:--INSPECTION&MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL; RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UPIAND HAULED AWAY BY EITHER CONTRAC'T'OR OR OWNER "FAILURE TO COMPLY' ITH,THE CONSTRUCTION LIEN LAVA CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOi�BUILIDING?IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. 518.00 14 Date: 5/15/08 01 Receipt: 0056936 CHECKS 8`6 ATTANTIC B-EAdH BUILtMG DEPT. 0810®sm322100€3 CITY OF ATLANTIC BEACH APP CATION FOR ENCS PERMIT Owners /� v Q Phone - Address Lot, Block and/or Unit# Subdivision Contractor if Different From Owner 2),/-/V14� ��e 2ZO �� •Cj0 Corner or Interior Lot Valuation of Fence $ Type of Construction C! tlUA. S Attach Survey Showing location and height of fence as well as location of street(s). o � Ci1v of Atlantic L,an 0� Building and ening Owners Signa re Contractors Sig CITY OF ��asztic �eac� - ��viida 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 32233-5445 TELEPHONE(904)247-5800 FAX(904)247-5805 SUNCOM 852-5800 JUL f 2, 1997 TO fM 40M IT MAY CONCERN: We have reviewed the project at 1879 Beach Avenue and find that it meets all codes and ordinances of the City of Atlantic Beach}pertaining to building and zoning. The portion of the project which encroaches the Coastat Constructioa Controt erne- Was permitted contingent on approval by the Florida State Department of Enviornmen.tal Protection. sincerely, Ci-r-- Don 0. Ford BuMmg t#tidal Coc3rg4 Wod", II Zor* g Dhvetor RECEIVED CITY OF ATLANTIC BEACH NOV 1 ? 1991 PERMIT APPLICATION REMODEL, ADDITIONS, OR ALT ,T(WC,AfAntic Beach MOVING,DEMOLITIONS Building and Zoning `ei rl,>nn. R. Petroni owner(s) : Address:l q79 Reach Ave. Atl.an.ttc RchThone: 241 -001. 3 Ty Lot # 43 T Block or Unit # ' SubdivisionN. Atlantic Rch. IT 2 Contractor: T"ichard Carter State License # CRC 046779 Address: 1R72 Pe.achs ide Ct. Phone No: 241 -4787 City ,ktlanti_c "each State Fla. zip Code 32233 Describe work to be done: '?oom Extension Present use of building: Sin,-le family residence idenee valuation of Proposed Construction: $10, 000 Proposed use: Li.vinp-,, area Is this an addition? s'e'c' If yes, what are the dimensions of the added space: 6 ft. X 14'2" ft. Will the added area be heated and cooled? yes New electrical (or increase) ? no New plumbing fixtures? "40 New, fireplace?TM�n New Heat/AC? No SUBMIT TR= (CCb6fi CIAL) TFOO (RESIDENTIAL) COI-jPLETE SETS OF PLANS, INCLUDING SITE PLAN, SURVEY, ENERGY CODE FORMS, NOTICE OF COMaNCEiMENT, AND OWNER/CONTRACTOR AFFIDAVIT, IF OWNER IS CONTRACTOR. N (`S w r Signature OWNER: lit,-Date: J� Z3 �}7 .� Signature CONTRAC R: ` Date: f�' /� f 7 c-6co47,)ct Sworn to and subscribed before me this_ ? day of OJ V�hc«tt�t«ttt��«tttttcS�S��KStSt�tttSttti�St�S� Q Q�P����r`� ARY PUBL C S E OF FLORIDA AT L: E 1t•�Y PV6 Barbar;Diene Steeg a OF �c �• rcJ •;+ Notary Public,St=_tr of Florida N;�' 0 ' 'A ' Commissioallo.CC 358032 •; '�'ar�o My Camn:iss;;::?Exp:resUS/22/98 � ��(,. 14W3•NQTARY.F1%Notary ScrAce&B-db*Co. 'uautaellctacrattttrtlttttultattutclault� ®�1 } t PA�MINT.Q BUttE. . f ZrtTY Vit=AtLANTtC�� H' it r k "+ �? ads 1 I.�" SUCH AVs1i1 MmA 1, V*rm �,� PIO � TYV ��''°°tl��yyyy���y�+'yp. gym }���yyy I �+rw,'V#d�#�it F. .i W!; �+ �i1 M i'. li f PjC6 040- sxoo; NORTH AT41 C, Bz4q ': �V o'.o0 , % . ut; 4 2.640 , Y 25:o0 ° . 1040 3� 'nt c } AMM X1210 4 { 1. k Ctt y 0, ilk 1 �UiC�tnt�"1viATER(Al Rt)fIsi"446.Of3 l$.FROM'TWISW©R�KMusT:NNO ',Bt~.P�A,c. INPliBueSPAGE,ANli:ivlE.$T C EAR "iJi�AiV HAUL ?A1fNAY !" 3t R' ITRA�CTOR OROWNER IFAI, SIS L fit, F7 iEt ACfl� TQ` PPFt3� b.p�i�, i 'VIfHIH ARE FART OF tWt 'ERM�T Ai!tt SUt3JECT 'CI tt*t `rtE P AOv '►L � r ATLANTiC SEAiN l�It.E?1VG D1`PARTMEN7 . a 5 a { t w ,"�- CITY OF ATLANTIC BEACH, FLORIDA Approved by APPLICATION FOR ELECTRICAL, PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE:.! 19 IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. L ELECTRICAL FIRM: MASTER ELECTDkefAN SIGNATURE JOURNEYMAN NAME_ �N C- C 6A-'F(- ADDRESS) CL.- -E RFD BOX BLDG.SIZE BETWEEN: RES. K APT. ( ) comm. ( 1 PUBLIC ( ► INDUS. 1 I NEW( I OLD ( REW. ( ) ADDITION (A TRAILER ( ► TEMP. ( ) SIGNS i ) SO. FT. SERVICE: NEW ( 1 INCREASE ( 1 REPAIR ( 1 FEE CONDUCTOR SIZE AMPS COPPER ALUM. SWITCH OR BREAKER AMPS PH W VOLT RACEWAY EXIST.SERV.SIZE ZO© AMPS I PH 3 W Z'`FoVOLT Sc-v RACEWAY FEEDERS NO. SIZE NO. SIZE I NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.90 AMPS. 31.100 AMPS, SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPB. OVER APPLIANCES BELL TRANSF. AIR N.P. RATING H.P. RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 0-1 OVER MOTORS H.P. VOLTAGE PHS NO. 11i.P. VOLTAGE PHS MISCELLANEOUS CSC c 01'^c G 40 J �� C. s, �+ it It L CAT 1014 .. Uim 1, rots,a 107 4- ACC AYE �401000D FRAM-8 81 k Vol I 00 nVroVr Co ' ; . 3. " 90;Q" , e IOC P't PL ' � �.aine T Ad AW I IDA . 22 3 # w. � a .. L " '' IDSO T' „ y 4 � 122 {q,. y}�y( 1�eMt' ��MS, �y1y�yT�yY T1T Y4A' gW i`iYr� � T� � i Eat tt Qit`i(i MATERIAL#AUSSISH AND t7C*�RI^a R If.3Hta WORK t4lC1ST"PIQT. PL ltd PURL IC'SPAC ,A IE3 MU-ST', 3E' � �l!folN4 i14A4f, AWAY I�Y�I THOC,""Nf OR 6 tL , x ,ISSUE}; v D PLANS WHICH ARE PART 0#THt$ i-p J4Nn SUBJECT-to AEVOCAT)t� Of @ t:A . 3 [77 01 now k Illi R �' `�F 7 FLORIDA DEPARTMENT OF •■:•�•••r ENVIRON N' AL PROTECnON NOTICE TO PROCEED Permit Number: DU-227 Permittee: Permit Expires: October 6, 1999 Gerard Petroni c/o Kevin Partel, President Coastal Consulting and Restoration, P.A. 4230 Myrtle Street St. Augustine, Florida 32095 You are hereby granted final authorization to proceed with the construction or activities authorized by the permit number referenced above. Authorized work must conform with the detailed project description, approved plans, and all conditions including preconstruction requirements included in the final order. A brief description of the authorized work follows. Project Description: Construction of a two-story, single-family dwelling addition Project Location: Between approximately 120 feet and 170 feet south of the Department of x ' Environmental Protection's reference monument R-44, in Duval County. Project address: 1879 Beach Avenue, Atlantic Beach. Special Instructions: A preconstruction conference is required. Questions regarding the permit or this notice should be directed to the undersigned at: Bureau of Beaches and Coastal Systems 3900 Commonwealth Blvd. - M.S. 310 616 X 7 / � Tallahassee, Florida 32399-3000 Date of Notice Dana A. Latino, ]Engineer Telephone (850) 488-3180 DAL/jg cc: Permit File Permit Information Center Bobbie Nelson, Field Engineer David Apple, DEP District Office Gerard Petroni, Property Owner City of Atlantic Beach Building Official DEP Form 73.131Okov.011n Post Conspicuously on the Site ����oa�E�\R�PRCiE(iION r Department of SE Environmental Protection Marjory Stoneman Douglas Building Lawton Chiles 3900 Commonwealth Boulevard Virginia B. Wetherell Governor Tallahassee, Florida 32399-3000 Secretary October 6, 1997 Kevin Partel, President Coastal Consulting and Restoration, P.A. 4230 Myrtle Street St. Augustine, Florida 32095 Dear Mr. Partel: NOTICE TO PROCEED PERMIT NUMBER: DU-227 PERMITTEE NAME: Gerard Petroni Your request for a permit pursuant to Section 161.053, Florida Statutes, for construction or other activities seaward of the coastal construction control line,has been approved by the Department of Environmental Protection. However, construction may not commence until after the permittee complies with any preconstruction requirements described in Special Permit Condition 1. Please read the permit and permit conditions including both the Standard Permit Conditions and any Special Permit Conditions closely before starting construction. Standard Permit Conditions 1(q), and 1(s), pertain to written reports which must be submitted to the Department of Environmental Protection under the signature and seal of a professional engineer, architect, or land surveyor (as appropriate) at specified times. Forms for use in preparation of these reports are enclosed. Make sufficient copies of the periodic report form to provide the required reports. The periodic reports are due in the office of the Bureau of Beaches and Coastal Systems on a monthly basis on the last working day of each month. No progress reports are required until such time as construction activities have started. The permit will expire two years after the date of issuance of the final order. Upon receipt of a written request signed by the permittee or authorized agent, the Department will consider extending the permit for up to but no more than one additional year. You must apply for a new permit for completion of any work not accomplished under the original permit. Although you may apply for a new permit, there is no assurance that such new permit for the same construction or activities would be approved. Any party to this proceeding has the right to request review of this order by the Governor and Cabinet, sitting as the Florida Land and Water Adjudicatory Commission, in accordance with section 20.255 of the Florida Statutes. To initiate such a review, you must file a request for it, and the request must be received by a member of the Commission or the Secretary of the Commission at The Capitol, Tallahassee, Florida 32399, within twenty days after this order is clerked. You must also serve both the Department of Environmental Protection, Department Clerk, 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399, and any other person named in this order with a copy of the request within twenty days after rendering of this order. "Protect, Conserve and Manage Florida's Environment and Natural Resources" Printed on recycled paper. Kevin Partel, President October 6, 1997 Page 2 Additionally, any person whose substantial interests are affected by any decision of the Department on the application has the right to request an administrative,hearing in accordance with the provisions of sections 120.569 and 120.57 of the Florida Statutes. Should you desire an administrative hearing, your request must comply with the provisions of rule 62-103.155(2) of the Florida Administrative Code, as indicated below. Send requests for hearings to the Department of Environmental Protection, Office of General Counsel, 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399. The Department must receive the request within fourteen days after your receipt of this notice. When the Department receives an adequate and timely filed request for hearing, the Department will request the assignment of a hearing officer. Likewise, when the Florida Land and Adjudicatory Commission receives an adequate and timely petition, the Commission will request the assignment of a hearing officer. Once a hearing officer is requested, the referring agency will take no further action with respect to the proceeding except as a party litigant, as long as the Division of Administrative Hearings has jurisdiction over the formal proceeding. Rule 62-103.155(2) of the Florida Administrative Code requires that a petition or request for hearing contain the following information: (a) The name, address, and telephone number of each petitioner, the applicant's name and address, the Department file number, and the county in which the proposed project would be located; (b) A statement of how and when each petitioner received notice of the Department's action or proposed action; (c) A statement of how each petitioner's substantial interests are affected by the Department's action or proposed action; (d) A statement of the material facts disputed by the petitioner, if any; (e) A statement of facts that the petitioner contends warrant reversal or modification of the Department's action or proposed action; (f) A statement of which rules or statutes that the petitioner contends require reversal or modification of the Department's action or proposed action; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wants the Department to take. A person may request an extension of time to petition for an administrative hearing. The person filing the request for extension must do so within the time limits for filing a petition described above and serve all parties with the request. The request must state why an extension is needed. The Department will grant an extension only when good cause is shown. If a petition or request for extension of time is filed, further order of the Department becomes necessary to effectuate this notice. Accordingly, the Department's final action may be different from the position taken by it in this notice. Actions undertaken by you under this permit, pending the lapse of time allowed for the filing of such a request for hearing, may be subject to modification, removal, or restoration. Kevin Partel, President October 6, 1997 Page 3 Failure to petition within the allowed time frame constitutes waiver of any right that such a person has to request a hearing under section 120.57 of the Florida Statutes and to participate as a party to the proceeding. If a legally sufficient petition for hearing is not timely received this notice constitutes final agency action. When this order becomes final, any party to the order has the right to seek judicial review under section 120.68 of the Florida Statutes and rule 9.030(b)(1) and 9.110 of the Florida Rules of Appellate Procedure by filing a notice of appeal with the Department of Environmental Protection, Office of General Counsel, Department Clerk, 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399, and with the appropriate district court of appeal within thirty days after rendition of this order. The notice filed with the district court must be accompanied by the filing fee specified in subsection 35.22(3) of the Florida Statutes. Any subsequent intervention will only be at the approval of the presiding officer upon motion filed under Rule 60Q-2.010, Florida Administrative Code. A person whose substantial interests are affected by the Department's proposed agency action may choose to pursue mediation as an alternative remedy under section 120.573 before the deadline for filing a petition. Choosing mediation will not adversely affect the right to a hearing if mediation does not result in a settlement. The procedures for pursuing mediation are set forth below. A person may pursue mediation by reaching a mediation agreement with all parties to the proceeding (which include the applicant, the Department, and any person who has filed a timely and sufficient petition for a hearing) and by showing how the substantial interests of each mediating party are affected by the Department's action or proposed action. The agreement must be filed in (received by) the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, by the same, deadline as set forth above for the filing of a petition. The agreement to mediate must include the following: (a) The names, addresses, and telephone numbers of any persons who may attend the mediation; (b) The name, address, and telephone number of the mediator selected by the parties, or a provision for selecting a mediator within a specified time; (c) The agreed allocation of the costs and fees associated with the mediation; (d) The agreement of the parties on the confidentiality of discussions and documents introduced during mediation; (e) The date, time, and place of the first mediation session, or a deadline for holding the first session, if no mediator has yet been chosen; (f) The name of each party's representative who shall have the authority to settle or recommend settlement, and (g) Either an explanation of how the substantial interests of each mediating party will be affected by the action or proposed action addressed in this notice of intent or a statement clearly identifying the petition for hearing that each party has already filed, and incorporating it by reference. (h) The signatures of all parties or their authorized representatives. Kevin Partel, President October 6, 1997 Page 4 As provided in section 120.573 of the Florida Statutes, the timely agreement of all parties to mediate will toll the time limitations imposed by sections 120.569 and 120.57 for requesting and holding an administrative hearing. Unless otherwise agreed by the parties, the mediation must be concluded within sixty days of the execution of the agreement. If mediation results in settlement of the administrative dispute, the Department must enter a final order incorporating the agreement of the parties. Persons whose substantial interest will be affected by such a modified final decision of the Department have a right to petition for a hearing only in accordance with the requirements for such set forth above, and must therefore file their petitions within fourteen days of receipt of this notice. If mediation terminates without settlement of the dispute, the Department shall notify all parties in writing that the administrative hearing processes under sections 120.569 and 120.57 remain available for disposition of the dispute, and the notice will specify the deadlines that then will apply for challenging the agency action and electing remedies under those two statutes. You are advised that notice of this agency's final action on this permit has been given to other interested parties. They have fourteen days from receipt of the notice to exercise any rights they may have under Chapter 120, Florida Statutes. Actions undertaken by you under this permit, during this period may be subject to modification, removal or restoration. The authorized work is strictly limited to that described on the enclosed final order. Please direct any questions pertaining to this permit to me by letter at the above address, or by telephone at 850/487-4475. Sincerely, Dana A. Latino, Engineer Bureau of Beaches and Coastal Systems DAL/jg Enclosures cc: Permit Information Center Bobbie Nelson, Field Engineer David Apple, DEP District Office City of Atlantic Beach Building Official Gerard Petroni, Property Owner STATE OF FLORIDA ' DEPARTMENT OF ENVIRONMENTAL PROTECTION Division of Water Facilities XA Bureau of Beaches and Coastal Systems 00FLOR3900 Commonwealth Blvd. - Mail Station 3 Tallahassee, Florida 32399-3000 (850) 488-3180 PERMIT NUMBER: DU-227 PERMITTEE Gerard Petroni c/o Kevin Partel, President Coastal Consulting and Restoration, P.A. 4230 Myrtle Street St. Augustine, Florida 32095 PERMIT FOR CONSTRUCTION OR OTHER ACTIVITIES PURSUANT TO SECTION 161.053, FLORIDA STATUTES FINAL ORDER FINDINGS OF FACT: An application for authorization to conduct the activities seaward of the coastal construction control line which are indicated in the project description, was filed by the applicant/permittee named herein on June 12, 1997, and was determined to be complete pursuant to rule on July 10, 1997. The proposed project is to be located landward of the 30-year erosion projection and the existing line of construction established by major structures in the immediate area. CONCLUSIONS OF LAW: After considering the merits of the proposal and any written objections from affected persons, the Department finds that upon compliance with the permit conditions, the activities indicated in the project description are of such a nature that they will result in no significant adverse impacts to the beach/dune areas or to adjacent properties; that the work is not expected to adversely impact nesting sea turtles, their hatchlings, or their habitat; that the work is expendable in nature and/or is appropriately designed in accordance with Rule 62B-33.007, Florida Administrative Code; and that it is an activity or type of construction which the designee of the Chief of the Bureau of Beaches and Coastal Systems has authority to approve or deny pursuant to Administrative Directive DEP 140, effective July 1, 1993. Based on the foregoing considerations, the designee approves the application; authorizes construction and/or activities at the location indicated below in strict accordance with the project description, the approved plans (if any) and the Standard Permit Conditions which are attached and are by this reference incorporated herein, and any additional conditions shown below, pursuant to Subsection 161.053(5), Florida Statutes. EXPIRATION DATE: October 6 , 1999 LOCATION: Between approximately 120 feet and 170 feet south of the Department of Environmental Protection's reference monument R-44, in Duval County. Project address: 1879 Beach Avenue, Atlantic Beach. PERMITTEE: Gerard Petroni PERMIT NUMBER: DU-227 PAGE 2 PROJECT DESCRIPTION: Two-Story, Single-Family Dwelling Addition 1. Location relative to control line: A maximum of 50 feet seaward. 2. Exterior dimensions: From 6 feet in the shore-normal direction by 14.2 feet in the shore-parallel direction. 3. Type of foundation: Continuous concrete footer. 4. Bottom of concrete footing: +15.8 feet (NGVD). 5. Finished floor elevation (first floor): +21.8 feet (NGVD). SPECIAL PERMIT CONDITIONS: 1. Prior to the start of construction, a preconstruction conference shall be held at the site among the contractor, the owner or authorized agent, and a staff representative of the Bureau of Beaches and Coastal Systems to establish an understanding among the parties as to the items specified in the special and standard conditions of the permit. The proposed locations of the structures shall be staked out for the conference. Please call Ms. Bobbie Nelson at (800)446-8967 for an appointment. 2. Prior to commencement of construction activity authorized by this permit, a temporary construction fence shall be erected along the perimeter of the permitted activity. The fence shall remain in place until the construction authorized by this permit is complete. The optimum siting of the construction fence shall be determined during the preconstruction conference by the staff representative of the Bureau of Beaches and Coastal Systems, so as to provide maximum protection to the existing vegetation located on the site. 3. No new permanent exterior lighting is authorized. Approved plans are incorporated into this permit by reference. Done and ordered this G_*�day of �c��J{'► 1997, in Tallahassee, Florida. Attachment: Standard Permit Conditions FILING AND ACKNOWLEDGEMENT State of Florida FILED, on this date, pursuant to S 120.52 Department of Environmental Protection Florida Statutes, with the designated C-75 Department Clerk, receipt of whicht� is hereby acknowledged. Gene Chalecki, P.E. Engineering Supervisor /A M/ 7 Bureau of Beaches and Coastal Systems Deputy Clerk Date FLA 1*01 LAWS AAMCO Ponta Me /• 111.1 NuuVir of (1VnMWnrrnWnt OwMI��w wrin��sl V) The undersigned hereby informs all concerned that Improvements will be mads to certain real Ch property, and in accordance with section 713.13 of the Florida Statutes„ the following information 01 is stated in this NOTICE OF COMMENCEMENT. CL Qsacription of property..—.— 1971) Reach Ave.�Atlantic» Beach. Flamm 32?_33.. ._....._.......... N �. L,nt 43 Block 11 North Atlantic 1?each Tini_t 2 m as recorded in P7.at [)ook 15 I'ap;e 57 or the � .................................... _.. .......w... .._ . »_. ....... ......_.............._......»..........»»....»._.......... .... »._....»..... .»..._...... ........... ppublic records of Duval County, Florida _............. ......... ............»...».............._...........».................. ................._.........._. .. .►...... .» _....... Genal deaa*Non of W*Mww m*s. . . . o om...ad r_i i t i_on General l';. . 5........»»......».....». .. _.... 5566-7 _. ...»...... ... » .. ... ...................................�...... .a.]Qce �2 _.._.... ...._............ CLERK CIRCUIT \, eidtrnn R. Petroni DUVAL COUNTY UST Owner.......__... ..............._......»___....__..»» ._:...»...»..........»...»..».......................».........NE� ..�...�... .».t.�� ....................... 1271) Beach Ave. Atlantic Beach, Fla. 32233 Owner's i ier d In aIle of Ow is�rovesesrM...»_.....» .._..»_.1;e e. gimp 1 e _... ........... Fee U*G We Moiler P ellnr than *"W) Peidunn f3 . Petr_oni f�laele.............. _ ._.._..... ....,. ..»..........,.»................................................_..._.........»_...».............. » ......_...... ..._.__. . 1 R7p Reach Aire Atlantic Peach, Fla. 32233 Address......»..»_. .... ...........».........................................._....... .........�». ..........._......».. T�Ichard F. Carter CBC 06677 �� »»..._..»»...._...».. _ _. ._... .. _ 11972_ Reachsi.de Ct . AtlanticBeach, . !-,'Ia. 32233 _» unty 0 404• N/A ..._......»..»...............»».... .....»»..»..».»»....... .._..»..__... N/AAddress ......Am%x tt of bort :......_..._....» Nan+e of pareen within Ae $we of 116"alesi0na�i by Owner upon wham rrotiaes or oi+her doa "M trry be served! Reidunn B . Petroni erne.._._... _..._....... _.. ....._.......»............. 11979 Beach Ave. Atlantic reach, MFla. 32233 In addition to himself,owner designetaa the following pereori to roe"a copy of the Lienors Notice as provided in Section 713.13(1) (F), Florida Statutes. IFIll 1n at Owner's option). Name......__.._._...�_. » .........» .......»............. 1 fYl• Y�l.!�Y �!lY�Y.�uv�.r.. 1 � CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET p Address t 0 � � r� F V�-C- (:I V F Date / I- ;7-(j --� 7-- Heated Sauare Footage @ $ per ST :t = S Garage/Shed -ul!�@ $ per sq f = S Carport/Porch ��►` is S —per sa t = S i Deck A @ S Patio S per Sa *t S 00 TOTAL VALUATION : S 6-0061 14 e� Total Valuation 1st $ (goe> Remaining Value Ys-.ec>per thousand or portion .the-reof TOTAL BUILDING FEE ti o b + 1/ -- Filing Fee ( 1 Fireplaces @ $15 . 0 S o BUILDING PERMIT FEE S ci O- 00 WATER IMPACT FEE S_ SEWER IMPACT FEE S WATER METER/TAP CAPITAL IMPROVEMENT S SEWER TAP S l i RADON (HRS ) 0050 5 SECTION H PAVING i S HYDRAULIC SHARES S CROSS CONNECTION S ( ) SURCHARGE . 0 0 5 0 S OTHER $ GRAND TOTAL DUE ADDITIONAL PERMITS OR FEES : Mechanical Plumbing Electric/New Electric/Temp : SwimmingPool Septic Tanis Well ; Sign Finish Floor Elevation Survey Other CALCULATIONS and/ or NOTES : i CITY OF ATLANTIC BEACH PERMIT APPLICATION REMODEL, ADDITIONS, OR ALTERATIONS MOVING,DEMOLITIONS Owner(s): Pei.dimn R. Petroni Address: 1 R70 Reach, Ave. Phone: 241 -6913 Lot # 43 Block or Unit # �j Subdivision: N . Atlantic Beach Unit 2 Contractor: ?iehard F. Carter State License N CRC X46779 Address: 1 ,972 Reachside Ct. Phone No: 241 -4787 city atlantic Reach State Fla. Zip Code 32233 i Describe work to be done: Room Extension i Present use of building: Single Family Dwelling i ! Valuation of Proposed Construction: Ten Thousand s # L i vin?; Area Proposed use: Is this an addition? Yes If yes, what are the dimensions of the added space: 6n" ft. X 14 '2" ft. Will the added area be heated and cooled? Yes New electrical (or increase) ? No New plumbing fixtures? No New fireplace?No New Heat/AC? No SUMaT TIM" (CM9RCIAL) TWO (RESIDENTIAL) =VLETE SETS OF PLANS, INCLUDING SI2T PLAN, SURVEY, ENERGY CODE FoRbW, NOTICE OF COMONCEMSTT, AND 0WAWCONTMCTOR AFFIDAVIT, IF ON= IS CONTRACTOR. Signature OWNER: � PL^-Date: Signature CONTRAC R: Date: 1 C1be-C,%4 //�� '' Sworn to and subscribed before me thisQday of /IIUUPln Ler= 19 T p 7 RECEIVED wi*tl I o 1997 .. . City of Atlantic Beach Barbara Diane Stag Notary Public,State of Florida Building and Zoning I Commission No.CC 368052 os ao My Commission Expire 05/22/98 14SM-Naraev-pta.NMUY&rAft g e !llClKlllt!!!lllflllllllCClllIKKKI!lllllllKC FLORIDA DEPART NM OF ENVIRONMENTAL PROTECTION NOTICE TO ]PROCEED x; Permit Number: DU-227 Permittee: Permit Expires: October 6, 1999 Gerard Petroni c/o Kevin Partel, President Coastal Consulting and Restoration, P.A. 4230 Myrtle Street St. Augiisti.ne,, Florida 32095 You are hereby granted final authorization to proceed with the construction or activities authorized by the permit number referenced above. Authorized work must conform with the detailed project description, approved plans, and all conditions including preconstruction requirements included in the final order. A brief description of the authorized work follows. Project Description: Construction of a two-story, single-family dwelling addition Project Location: Between approximately 120 feet and 170 feet south of the Department of w Environmental Protection's reference monument R-44, in Duval County. Project address: 1879 Beach Avenue, Atlantic Beach. Special Instructions: A preconstruction conference is required. Questions regarding the permit or this notice should be directed to the undersigned at: Bureau of Beaches and Coastal Systems 3900 Commonwealth Blvd. - M.S. 310 Tallahassee, Florida 32399-3000 Date of Notice Dana A. Latino, Engineer Telephone (850) 488-3180 DAL/jg cc: Permit File RFcr1VrD Permit Information Center Bobbie Nelson, Field Engineer David Apple, DEP District Office NOV 12 1997 Gerard Petroni, Property Owner City of Atlantic Beach Building Official City of Atlantic Beach Building and Zoning DEP Foam 73131(Rev.01/97) Post Conspicuously on the Site Department of K _ _ Environmental Protection Marjory Stoneman Douglas Building Lawton Chiles 3900 Commonwealth Boulevard Virginia B.Wetherell Governor Tallahassee, Florida 32399-3000 Secretary October 6, 1997 Kevin Partel, President Coastal Consulting and Restoration, P.A. 4230 Myrtle Street St. Augustine, Florida 32095 Dear Mr. Partel: NOTICE TO PROCEED PERMIT NUMBER: DU-227 PERMITTEE NAME: Gerard Petroni Your request for a permit pursuant to Section 161.053, Florida Statutes, for construction or other activities seaward of the coastal construction control line,has been approved by the Department of Environmental Protection. However, construction may not commence until after the permittee complies with any preconstruction requirements described in Special Permit Condition 1. Please read the permit and permit conditions including both the Standard Permit Conditions and any Special Permit Conditions closely before starting construction. Standard Permit Conditions 1(q), and 1(s), pertain to written reports which must be submitted to the Department of Environmental Protection under the signature and seal of a professional engineer, architect, or land surveyor (as appropriate) at specified times. Forms for use in preparation of these reports are enclosed. Make sufficient copies of the periodic report form to provide the required reports. The periodic reports are due in the office of the Bureau of Beaches and Coastal Systems on a monthly basis on the last working day of each month. No progress reports are required until such time as construction activities have started. The permit will expire two years after the date of issuance of the final order. Upon receipt of a written request signed by the permittee or authorized agent, the Department will consider extending the permit for up to but no more than one additional year. You must apply for a new permit for completion of any work not accomplished under the original permit. Although you may apply for a new permit, there is no assurance that such new permit for the same construction or activities would be approved. Any party to this proceeding has the right to request review of this order by the Governor and Cabinet, sitting as the Florida Land and Water Adjudicatory Commission, in accordance with section 20.255 of the Florida Statutes. To initiate such a review, you must file a request for it, and the request must be received by a member of the Commission or the Secretary of the Commission at The Capitol, Tallahassee, Florida 32399, within twenty days after this order is clerked. You must also serve both the Department of Environmental Protection, Department Clerk, 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399, and any other person named in this order with a copy of the request within twenty days after rendering of this order. "Protect, Conserve and Manage Florida's Environment and Natural Resources" Printed on recycled paper. Kevin Partel, President October 6, 1997 Page 2 Additionally, any person whose substantial interests are affected by any decision of the Department on the application has the right to request an administrative hearing in accordance with the provisions of sections 120.569 and 120.57 of the Florida Statutes. Should you desire an administrative hearing, your request must comply with the provisions of rule 62-103.155(2) of the Florida Administrative Code, as indicated below. Send requests for hearings to the Department of Environmental Protection, Office of General Counsel, 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399. The Department must receive the request within fourteen days after your receipt of this notice. When the Department receives an adequate and timely filed request for hearing, the Department will request the assignment of a hearing officer. Likewise, when the Florida Land and Adjudicatory Commission receives an adequate and timely petition, the Commission will request the assignment of a hearing officer. Once a hearing officer is requested, the referring agency will take no further action with respect to the proceeding except as a party litigant, as long as the Division of Administrative Hearings has jurisdiction over the formal proceeding. Rule 62-103.155(2) of the Florida Administrative Code requires that a petition or request for hearing contain the following information: (a) The name, address, and telephone number of each petitioner, the applicant's name and address, the Department file number, and the county in which the proposed project would be located; (b) A statement of how and when each petitioner received notice of the Department's action or proposed action; (c) A statement of how each petitioner's substantial interests are affected by the Department's action or proposed action; (d) A statement of the material facts disputed by the petitioner, if any; (e) A statement of facts that the petitioner contends warrant reversal or modification of the Department's action or proposed action; (f) A statement of which rules or statutes that the petitioner contends require reversal or modification of the Department's action or proposed action; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wants the Department to take. A person may request an extension of time to petition for an administrative hearing. The person filing the request for extension must do so within the time limits for filing a petition described above and serve all parties with the request. The request must state why an extension is needed. The Department will grant an extension only when good cause is shown. If a petition or request for extension of time is filed, further order of the Department becomes necessary to effectuate this notice. Accordingly, the Department's final action may be different from the position taken by it in this notice. Actions undertaken by you under this permit, pending the lapse of time allowed for the filing of such a request for hearing, may be subject to modification, removal, or restoration. Kevin Partel, President October 6, 1997 Page 3 Failure to petition within the allowed time frame constitutes waiver of any right that such a person has to request a hearing under section 120.57 of the Florida Statutes and to participate as a party to the proceeding. If a legally sufficient petition for hearing is not timely received this notice constitutes final agency action. When this order becomes final, any party to the order has the right to seek judicial review under section 120.68 of the Florida Statutes and rule 9.030(b)(1) and 9.110 of the Florida Rules of Appellate Procedure by filing a notice of appeal with the Department of Environmental Protection, Office of General Counsel, Department Clerk, 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399, and with the appropriate district court of appeal within thirty days after rendition of this order. The notice filed with the district court must be accompanied by the filing fee specified in subsection 35.22(3) of the Florida Statutes. Any subsequent intervention will only be at the approval of the presiding officer upon motion filed under Rule 60Q-2.010, Florida Administrative Code. A person whose substantial interests are affected by the Department's proposed agency action may choose to pursue mediation as an alternative remedy under section 120.573 before the deadline for filing a petition. Choosing mediation will not adversely affect the right to a hearing if mediation does not result in a settlement. The procedures for pursuing mediation are set forth below. A person may pursue mediation by reaching a mediation agreement with all parties to the proceeding (which include the applicant, the Department, and any person who has filed a timely and sufficient petition for a hearing) and by showing how the substantial interests of each mediating party are affected by the Department's action or proposed action. The agreement must be filed in (received by) the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, by the same deadline as set forth above for the filing of a petition. The agreement to mediate must include the following: (a) The names, addresses, and telephone numbers of any persons who may attend the mediation; (b) The name, address, and telephone number of the mediator selected by the parties, or a provision for selecting a mediator within a specified time; (c) The agreed allocation of the costs and fees associated with the mediation; (d) The agreement of the parties on the confidentiality of discussions and documents introduced during mediation; (e) The date, time, and place of the first mediation session, or a deadline for holding the first session, if no mediator has yet been chosen; (f) The name of each party's representative who shall have the authority to settle or recommend settlement, and (g) Either an explanation of how the substantial interests of each mediating party will be affected by the action or proposed action addressed in this notice of intent or a statement clearly identifying the petition for hearing that each party has already filed, and incorporating it by reference. (h) The signatures of all parties or their authorized representatives. Kevin Partel, President October 6, 1997 Page 4 As provided in section 120.573 of the Florida Statutes, the timely agreement of all parties to mediate will toll the time limitations imposed by sections 120.569 and 120.57 for requesting and holding an administrative hearing. Unless otherwise agreed by the parties, the mediation must be concluded within sixty days of the execution of the agreement. If mediation results in settlement of the administrative dispute, the Department must enter a final order incorporating the agreement of the parties. Persons whose substantial interest will be affected by such a modified final decision of the Department have a right to petition for a hearing only in accordance with the requirements for such set forth above, and must therefore file their petitions within fourteen days of receipt of this notice. If mediation terminates without settlement of the dispute, the Department shall notify all parties in writing that the administrative hearing processes under sections 120.569 and 120.57 remain available for disposition of the dispute, and the notice will specify the deadlines that then will apply for challenging the agency action and electing remedies under those two statutes. You are advised that notice of this agency's final action on this permit has been given to other interested parties. They have fourteen days from receipt of the notice to exercise any rights they may have under Chapter 120, Florida Statutes. Actions undertaken by you under this permit, during this period may be subject to modification, removal or restoration. The authorized work is strictly limited to that described on the enclosed final order. Please direct any questions pertaining to this permit to me by letter at the above address, or by telephone at 850/487-4475. Sincerely, la,� - C , ��X96 Dana A. Latino, Engineer Bureau of Beaches and Coastal Systems DAL/jg Enclosures cc: Permit Information Center Bobbie Nelson, Field Engineer David Apple, DEP District Office City of Atlantic Beach Building Official Gerard Petroni, Property Owner STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION $� " Division of Water Facilities /4 l Bureau of Beaches and Coastal Systems FLORIDA 3900 Commonwealth Blvd. - Mail Station 300 Tallahassee, Florida 32395-3000 (850) 488-3180 PERMIT NUMBER: DU-227 PERMITTEE Gerard Petroni c/o Kevin Partel, President Coastal Consulting and Restoration, P.A. 4230 Myrtle Street St. Augustine, Florida 32095 PERMIT FOR CONSTRUCTION OR OTHER ACTIVITIES PURSUANT TO SECTION 161.053, FLORIDA STATUTES FINAL ORDER FINDINGS OF FACT: An application for authorization to conduct the activities seaward of the coastal construction control line which are indicated in the project description, was filed by the applicant/permittee named herein on June 12, 1997, and was determined to be complete pursuant to rule on July 10, 1997. The proposed project is to be located landward of the 30-year erosion projection and the existing line of construction established by major structures in the immediate area. CONCLUSIONS OF LAW: After considering the merits of the proposal and any written objections from affected persons, the Department finds that upon compliance with the permit conditions, the activities indicated in the project description are of such a nature that they will result in no significant adverse impacts to the beach/dune areas or to adjacent properties; that the work is not expected to adversely impact nesting sea turtles, their hatchlings, or their habitat; that the work is expendable in nature and/or is appropriately designed in accordance with Rule 62B-33.007, Florida Administrative Code; and that it is an activity or type of construction which the designee of the Chief of the Bureau of Beaches and Coastal Systems has authority to approve or deny pursuant to Administrative Directive DEP 140, effective July 1, 1993. Based on the foregoing considerations, the designee approves the application; authorizes construction and/or activities at the location indicated below in strict accordance with the project description, the approved plans (if any) and the Standard Permit Conditions which are attached and are by this reference incorporated herein, and any additional conditions shown below, pursuant to Subsection 161.053(5), Florida Statutes. EXPIRATION DATE: October 6 , 1999 LOCATION: Between approximately 120 feet and 170 feet south of the Department of Environmental Protection's reference monument R-44, in Duval County. Project address: 1879 Beach Avenue, Atlantic Beach. s PERMITTEE: Gerard Petroni PERMIT NUMBER: DU-227 PAGE 2 PROJECT DESCRIPTION: Two-Story, Single-Family Dwelling Addition 1. Location relative to control line: A maximum of 50 feet seaward. 2. Exterior dimensions: From 6 feet in the shore-normal direction by 14.2 feet in the shore-parallel direction. 3. Type of foundation: Continuous concrete footer. 4. Bottom of concrete footing: +1_5.8 feet (NGVD). 5. Finished floor elevation (first floor): +21.8 feet (NGVD). SPECIAL PERMIT CONDITIONS: 1. Prior to the start of construction, a preconstruction conference shall be held at the site among the contractor, the owner or authorized agent, and a staff representative of the Bureau of Beaches and Coastal Systems to establish an understanding among the parties as to the items specified in the special and standard conditions of the permit. The proposed locations of the structures shall be staked out for the conference. Please call Ms. Bobbie Nelson at (800)446-8967 for an appointment. 2. Prior to commencement of construction activity authorized by this permit, a temporary construction fence shall be erected along the perimeter of the permitted activity. The fence shall remain in place until the construction authorized by this permit is complete. The optimum siting of the construction fence shall be determined during the preconstruction conference by the staff representative of the Bureau of Beaches and Coastal Systems, so as to provide maximum protection to the existing vegetation located on the site. 3. No new permanent exterior lighting is authorized. Approved plans are incorporated into this permit by reference. Done and ordered this �' nD _ � day of �c.��'()'�'► 1997, in Tallahassee, Florida. Attachment: Standard Permit Conditions FILING AND ACKNOWLEDGEMENT State of Florida FILED, on this date, pursuant to S 120.52 Department of Environmental Protection Florida Statutes, with the designated Department Clerk, receipt of which is hereby acknowledged. Gene Chalecki, P.E. ZL7Engineering Supervisor Bureau of Beaches and Coastal Systems Deputy Clerk Date y} I �SI , NO �{VA }�`�q} r� ` A A.f "RSA} �`. � �IKi� }+�w JJ ropq to �A� " tit t, ' i T. P.fp I 4` I. ITV ' 4 aM�y rw.e+r,MK+wt tw�;ww do ,� � ._. r t �w�■. ', , I C5� t� � } i Y Je'" ei, 4-1272,3 � dF ! PA +� ;� Co 77 SAM, o 1 � I �Fl r r .r t BUILDW M #HIS 1N( FC M afCE, aTBE >' DOW ��liR1 M iQ��Fr �j 5 a T.�tlEA� p t 5y�!iSv '1a?}AL6M�iLHM1`t . .. ...,41R er4t .M 121 ' 5 .r DEPARTMENT OF BUILDINt'i CITY 00 ATLANTIC BEACH PERMIT INPORMA.TION" - -- LOBATION INPORMATIQN _- Permit Nuntber: 12135 Address : < 1879 BEACH AVENUE Permit Type:RLE" ROOP ATLANTIC BEACH, FLORIDA 32233 Class of Work:ALTERATION --------- LEGAL DESCRIPTION -_-__-..___ Constr. type:WOOD' FRAME Block. Lot ., 43 Twp: Q Proposed Use: Section: 0 Subd:O Rng: Q Dwellings: I Subdivieion:NORTH ATLANTIC BEACH. Est . Value: 0 .00 Coo 2,09040 Tcatal Pep s: 25.04 A aunt 5.00 Date 9/1996 W4K? + NG SHINGLES; INSTALL 25 YEAR FUNGUS FIBERGLASS SHINGLIw - APPLICATION` FEES ___ -- TRONI . IT� 25..00 AddAdutra Veroo", : ENUE Pbcn . F S R FORMATI ------ Name: A Lzc: Exp: f T i t NO" E- ALL Wit' I� i,.AkN# Ft1OTIMGS MUST BE INSPECTED BEFORE'POUNNG PERMIT V©ICI,SIX MONTHS AFTER DATEOF ISSUE w ,'BUI1�0 MATERIAL,RUBBISH Ahlp i3EBRIS FROM THIS WORK MUST DICT BE PLACED IN PUOLlC SWAGE,AND IktIUST BE I;LI=AREt UP AIVL1 HAULED AWAY BY EITHER CONTRACTOR OR OWNER a COMPLY, WITH THE MECHANIC'S LIEN LAw cAN s-suLT [11, " ` � ►V#N TWICE'FORTHFORTHE BUILDING IMPOOVIWENTE ISSUEDACCORDING TO APPflUvEI PLANS WHICH ARE PART OF THIS PERMIT Air P RE T #CI.ATICI I O A PPLICASLe PAOV1S4ONiOP LAW, ATLANTIC BEACH'SUILDING DePARNENT Sy. . F r r CITY OF ALANTIC BEACH ROOFIG PERMIT' APPLICATION owner s) : l ,- c� 12 12KIA e-c (Z- t-k '% Address:, '/e 9 9 r ch fi U Q -Phone: Lot # Block or Unit # Subdivision: Contractor: '� L"-V a c4� Address : S 6 City, State and Zips Phone S 7-i Z F� State License # Z C U U 2 ,_( 7 e"7 Describe work to be performed: <Si/YLL Z S �-isz %4,4gz . syii��.�st�fSS Valuation of Proposed Construction: Materials to be used: �. Signature of Owner; ~ Signature of Contractor: C Liability Insurance Supplied Workers Compensation Insurance Supplied License Information ���p�FAOtE(110h` Y 71 Department of j F`oR `Ay . Environmental Protection Marjory Stoneman Douglas Building Lawton Chiles 3900 Commonwealth Boulevard Virginia B. Wetherell Governor Tallahassee, Florida 32399-3000 Secretary July 21, 1997 TO MOM IT MAY CONCERN Request for Public Comment - File Number: DU-227- Applicant: U-227-Applicant: Reldunn and Gerard P. Petroni You are hereby notified that the Department of Environmental Protection is considering the referenced application for a coastal construction control line permit, pursuant to Section 161.053, Florida Statutes, for the construction of landward addition to existing structure. A copy of the plans is enclosed. The proposed project is located approximately 120 feet to 170 feet south of the Department of Environmental Protection's reference monument R-44 in Duval County, and is within the local jurisdiction of the City of Atlantic. Project address: 1879 Beach Avenue, Atlantic Beach. This public comment notice is being distributed in order to assist the Department of Environmental Protection in developing facts on which to base a decision on the permit application. For accuracy and completeness all comments should be submitted in writing with supporting data, evidence, or rationale to furnish a clear understanding of the basis for the comments. The decision as to whether a permit will be issued will be based on an evaluation of: (1) The design adequacy of the proposed construction. (2) The expected impact of the proposed construction to the beach/dune system. (3) The expected impact of the proposed construction _to adjacent properties. (4) The expected impart of the proposed construction on lateral public beach access. (5) Appropriate siting of the proposed construction with respect to local setback, zoning restrictions, and maximum usage of upland portions of the property. (6) The expected impact of the proposed construction on nesting sea turtles and hatchlings and their habitat. Comments should be submitted within fourteen (14) calendar days after the date of this notice to Dana A. Latino, Engineer, the Florida Department of Environmental Protection, Bureau of Beaches and Coastal Systems, 3900 Commonwealth Boulevard, Mail Station 310, Tallahassee, Florida 32399. Plans for the proposed work may be seen at the office of the Bureau of Beaches and Coastal Systems at 5050 West Tennessee Street, Building B, Tallahassee, Florida. DL/Ir Enclosure "Protect, Conserve and Manage Florida's Environment and Notural Resources" Printed on recycled pooer. sr.nre...J tAu ��>'.�� S. 3pb� - � cwr... .s I ••.! �.1.J�-.it.c.na t..�r>s 'lil'w>bJ� /.CEJ Lief..+ FOp.. c�fF4 aKr V 4 45-0 _ e'o Ea.ar.Jc. neEE Soc1 n.Jed. - /CY>rw✓ .J Ti Vii.`-C i.[W r� c. sc......� �• .- I tea¢: 1•,Ip._o. CITY OF 800 SEMiNOLE ROAD ATLANTIC BEACH,FLORIDA 32233- ya -- - TELEPHONE(904)247-5800 � FAX(904)247-5805 June 11, 1996 Mr. Jerry Petroni 1879 Beach Avenue Atlantic Beach, FL 32233 Dear Mr. Petroni: On June 10, 1996 1 inspected the property at 1879 Beach Avenue and found the roofing shingles missing in several areas. At two locations I could not find any felt underneath the existing shingles. The Standard Building Code 1991 Edition, in use when this house was constructed, requires a minimum of one layer of 15 pounds felt underneath. Refer to Section 3204.2.2 1991 Standard Building Code. I have contacted Mr. Fouraker of Fouraker Construction Company. He has stated to me he will have the roof repaired/replaced to meet the code. Sincerely, ' cam _ C _ Don C. Ford Building Official DCF/pah Enclosure cc: City Manager €IIi'g OF R 'f Office pa; SuiEding O fici:a! REGUE-Sa FOR INSPEC T Ion Permit No. --- — — - -i me A.M, 3aceived _. P.M. 1 ?wrer'a v dame Contractor __ 3UtLDINC 6CREPE CLCCTHHCAL PLUMBING IMIECHANiCAL :tarringRough Wiring dough Air Cond. & to Roofing _ Slab � Temp Pnle Top Out Heating lsulation Lintel Fina, Sewar Fire Place READY FOR, INSPECT ION Pre Fab Son. Tues �. ) Thurs. Friday N.M. 7/ . ispertion Made P �C ctof — Gnal Inspection f - - Ccrtiticat of Oi:cupancy Dalft CITY OF !C ^3+ �oA'�� 9�k.•w,sfis`a"3'""' � A 4'.P` office of Building Official REOUE-ST FOR INSPECT ION D ... ! ate_ Permit Time 2O A.M Received /� r'� -- — Pm ob -- ^-Locality i Owner's Name _ -----Contractor — - CONCRETE ELECTRICAL PLUIOBINO MECHANICAL Framing Fooling Rough INiring Rough Air Conti & Re Roofing �= ,. Slab Temp Pole Top Out Heating F `yr Final Seeder re Place Insulation 7`� Lintel Pre Fab READY FOR tNSPECTiON M Rdon, Tues Wei Timis. Friday (� Inspection Made ___ i r' Final�i � al Inspection ! - - _ Certificate of Occupancy Vj 00 �, a ow,er; �1 Doug Se ve 5'• Get Temp pate - n�c - gSt.Cx pootin9 Fina '.:cPM�%'4"� Fri�ay i�9 tirSeA rjY ram Fin9 \ns`-�1a�tea FCL. Y sues Ger t cafe° CITY OF 9 Office of Building Official _ REQUEST FOR INSPECTION 7 3 Permit No. Date . TimeA.M. Received r� a/ P.M. cy Job Address Locality Owner's Name _.—_ Contractor CONCRETE �-- � C� tE L Framing footing Rough Wiring I[ Rough ❑ Air Cond. & Re Roofing Slab Temp Pale Top Out L Heating Insulation Lintel Final Sewer 0 Fire Place Pre Fab READY FOR INSPECTION ,,�,�/ A.M. Mon. Tues. Wed. � Friday_ P.M. Inspection Made M Final Inspection P cr_�✓° � '! r � — Certificate of Occupancy � f �-� Date ----- — -- CITY OF /3e -fir 9710 Office of Building Off cia 5;'l7 REQUEST FOR INSP ION 5�G 7 3 Date D / _ Permit No. Time A Received 1� M. J r s ty Owner' N —CoCo' =ntrac�� CB ' UILD CONCRETE SI EE H L �U,�MBI 7 MEChTRRt1CAL Framing Ell Footing Rough Wiring Rough G d, & ❑ Re Roofing CJ Slab F-_1 Temp Pole U� Top Out 1–jHeating Insulation ❑ Lintel Final C❑ Sewer ❑ Fire Place U, Pre Fab READY FOR INSPECTION Mon, Tues. We Thurs. Friday P.M1 Inspection Made _ __ P.M. Inspector_ _- _ Final Inspection Certificate of Occupancy ❑ Date e DATE• PRE-SERVICE DIVISION JACKSONVILLE ELECTRIC AUTHORITY 233 WEST DUVAL STREET JACKSONVILLE, FLORIDA 32202 THE FOLLOWING FINAL INSPECTION(S) HAVE BEEN MADE AND ARE SATISFACTORY: 23 , -- -- '-=-� ----------- U i 3 3_ ► l cla_JY_ _ z� - --------------- ---------------------------------------------- ------- ------------------------------------------------- Enclosed are the blue copies of the permits. SINCERELY BUILDING INSPECTION DIVISION cc:FILE 1 TRANSMITTAL DOCUMENT FOR JEA DATE: '/-C, -5;), The following permits have passed "rough" inspection: Permit No. Address F( -23 79 ve . gAz2b=Odc'a°«xxxzXgixkum*xm3Pdx sXcOfxxbk6x4Mz dYba. Please update your records accordingly. BUILDING CLERK • CITY. OF ATLANTIC BEACH /vcb i BUILDING AND ZONING INSPECTION DIVISION CITY OF ATLANTIC BEACH ATLANTIC BEACH, FLORIDA 32233 APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER IMPORTANT — Applicant to complete all items in sections I, II, III, and IV. I• - -- . LOCATION .Street Address: OF Intersecting Streets: Between And BUILDING Sub-division II. IDENTIFICATION — To be completed by all applicants , In consideration of permit given for doing the work as described in the above statement we hereby agree to perform said work in accordance with the attacFod plans and specifications which are a part hereof and in accordance with the City of Jacksonville ordinances and standards of good practice listed therein. Name of Mechanical �_„�,W _ Contractors Contractor (Print) � � Master " �., Name of Property Owner ` ` Signature of Owner` Signature of or Authorised Agent Architect or Engineer I. GENERAL IptFORMAT,16N A. Type of heating 8. �/ IS OTHER CONSTRUCTION BEING DONE ON 1q Electric THIS BUILDING OR SITEt ❑ Gas—❑ LP ❑ Natural ❑ Central Utility Q OII IF YES, GIVE NUMBER OF CONSTRUCTION 4 PERMIT 4 ❑ Other — Specify IV. MICHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK (Provide complete list of components on back of this form) Residential or ❑ Commercial Heat ❑ Space ❑ Recessed XCentral O Floor New Building Air Conditioning: ❑ Room X Central ❑ Existing Building Duct System: Material_ ^ Thickness ”` ❑ Replacement of existing system Maximum capacity c.f.m. New installation(No system previously Installed) ❑ Q Refrigeration Extension or add-on to existing system ❑ Other — Specify ❑ Cooling tower: Capacity q.p.m. ❑ firesprinklers: Number of heads ❑ Elevator ❑ Menlift ❑ Escalator (number) THIS SPACE POR OFFICE USE ONLY ❑ :Gasoline pumps (number) (Received) ❑ Tanks. (number) Remarks Q LPG containers (number) ❑ Unfired pressure vessel ❑ Boilers Permit Approved by Dai+ Q Other — Specify Permit Fe- LIST ALL EQUIPMENT AIR CONDITIONING AND REFRIGERATION EQUIPMENT Number Unites Description Yodel Number Manufacturer Caa��11tiy Approving(Tons) __ 4. o ' tj PSR 9844 y9414 00%vs DEPARTMENT OFBUILDI CATY OF ATLANTIC BEAC a 7 V , berm ' �- LOCATION INFORMATION PERMIT INFORMATION ....� ..,.�. PermitNumber: 941.4 �, Address w 1879 BEACH AVENUE 'hermit 'Type; BUILDING` � ATLANTIC L3EAG'I� FLORIDA V,233 ` � of Work: Lc t . �. . _ f GA *DESCRIPT ON -- - nst r, T pe: �T� FRAME _ . ,.,. y ection opo' sed pe. ` GARAGE/CARPOk hip RNC3. ' U ei 1 a rs : Code. "' R Subdivision: NORTH ATLANTIC >BEACB w Estimated Value: ,,'Improv. ;Cost : aDa Feet: 285, Tot �?� M 52285 ' 12 5/94 Work L}+ �"GAR,AGE/APART ENT PER PLANS - H:iF 751 . � TIO », `'' ='; .,.. ._.. APPLICATION PER$ TRONL ,. PERMIT Ad., , esrn*. H AVENUEA IMPACT P"EEy ;x , 290. +4 T CH r FL+ R I F�EETAP RADON GAS-H.R.S. 5325 .O0 NP'0RM3T tON RADON CAH 5% �, 57 'Name., IC F. CARTER�u e. API,TAL� It41ROVE. ....." S0 , 19 G!' SEWER TAP $0.00 ._ AT BEACH, FL 32233 CROSS CONNECTION $$35 .40 Type: 1, SEC H IMPACT FEF .m lo*.04 CONST.SURCRAR�aE o,ScHunair��"^ a . �y ,, �Vwfr ENOTES:F q(y ps NOTICE ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POURING l PERMIT VOId$IX +►ONTHS AFTEPP,TfOF ISSUE z. 1 p ' J ING MATERIAL,RUBBISH AND DEBRIS FF��OM THIS WORK MUST 1�.BE PLACE RED PUBLIC SPACE,AND Ml1ST f� ' REQ UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNE ' TILURE TO COMPLY WITH t'HE MECHANI "LIEN, LAW CAN RESULT IN E PROPERTY OWNER PAY1NQ TWICE FOIw BUILDING IMMOVEMENTS. 4wn, ACCORDING TO APPROVED PLANS WHICH ARE PART OF T ; ERMIT AND SUBJECT TO REVOCATION;FOR ON OF APPLICABLE PROVISIONS OF LAIIF: " f ATLANTIC I{i 0+ � oo $M.50 14 .. I. , .; oath, ORA/ i 4144,,A Rcpt: 041%W 8Y'k 77,777,7777, . 0971( DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH' t - .. .. PERMIT I OPORNAT I ON LOCATION I NFORIrfiAT I ON Pez sit Nuel ar» 9714, Address ,. 979. BEACH AVENUE Permit .'T�pew PLUMBING ATLANTIC BEACH, FLORIDA 3223.3 C fats Of W'drk» ADDITION RGAL I}ZSCRIPTION --------- - ` Cbristr . ..TYPe» WOOD FRAME Lot: Block: Section Propose Use* APARTMENTS Tounship: RNG 4 0 Dwe 114 » I Code» 4 Suk►d v s Y c� ; z t ima ed Value $0 .44 Imp ov. ;Cost'. So .00 Total. Fees'. $50.00 Amo S5 .QCI a k pL UMBIN IN GARAGE APARTMENT -� TION . ' APPLICATION FELLS PERM I It $50.00 I'i£t E° ": wH :AVIKNUE WATER IMPACT FEE 54 .44 ACH FLOR � 4 WA FEE OB qJ,TAP g ti RADON GAS-H.R.S. $0 .00 I NFORMA? Oft RADON CAB 5 06 $0 C� Nate 'STE L BIND ,, s CAPITAL, IMPROVE $4444 A'TL CI I BEACH Is'LO91DA 32213 CROSS CONNECTION $4 .00 Lige , r FC F T *Pe• 4 SEC H IMPACTFEE .00 CONST, SURCHARGE $y' 00 NOTES. NOTICE--ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POUAING � i } PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST`BE E CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER I "FA#LURE T4 CC�MFLY WITH THE MECHANIC'S L E t,AW 'CAN RESULT . THE RR�)�ERTY+C�tfVER PAYINGTWfCE FC}#�THk BU�Lf3fUGi#�IfRt�1/EMEf "'' ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT ANIS SUBJECT TO REV" I VIOLATION OF APPLICABLE PR(�UISIO.NS OF'L.AW. � n. ATLANTIC BEACH BUILDING DEPARTMENT tJ4IlOt e . J10/95 01' ." ' By. E f — fQ _- CITY OF ATLANTIC BEACH APPLICATION FOR PLUMBING PERMIT JOB LOCATION: :/ OWNER OF PROPERTY: BUILDING CONTRACTOR: /} ►c�L ��,�jte,� ■ r PLUMBING CONTRACTOR AND ADDRESS: TELEPHONE NUMBER: STATE LICENSE NO: C' 3 77. TYPE OF BUILDING: TYPE OF WORK: A/eLJ HOW MANY OF THE FOLLOWING FIXTURES INSTALLED SWIGS SUOWERS LAVATORY NATER HEATERS BATH TUBS _DISHWASHERS -URINALS ,Dispos"s t CLOSETS �� __MABRING MACHINE FLOOR DRAINS !!HONER PANS OTHER TOTAL FIXTURE COUNT: x $3.50 + $15.00 $ ---------------------------------------------------------------- INSTALLATION OF PLUMBING AND FIXTURES MUST 8E IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE. CALL A DAY AHEAD TO SCHEDULE INSPECTIONS - (904) 247-5826 SEWER CONNECTIONS MUST 8E CALLED INTO PUBLIC WORKS FOR INSPECTION BEFORE COVERING FTP - (904) 247-5834 CITY OF d t A r" a jar-dic } � �s'• i Offics of Building 0 icia! ;RE-MUEST FOR IN" E ON .2 DateQ7/6_ __--.... Permit No. -----`--------. Time Received _ _-! _ _ --_ P.M ;Pole; Job A �. Lo Owne N,-nle sNr�rneBUILDING CONCRET E ELPLUM MECHANICAL Framing Footing RouRough Air Oond. & 9 Roofing Slab TemiTop Out eating Insulafon Lintel Final Sewer ❑ Fire Place Pre Fab READY FOR fiNSPECTtON A.M. Mon. Tues. Wed. -1 hurs. Friday I Inspection -; - Cert'rflcatc-of Occupancy Datc CITY OF Office of Building Official ijkQUEST FOR INSPECTION Date Permit No. Time A.M. Received .M. 43 IF Job res Locali Owner's L4— Name _ Contractor _ BUILDING .--COIF ELECTRICAL PLUMBING MECHANICAL Framing `.---FSoting Rough Wiring Rough Air Cond. & _1 Re Roofing C Slab Temp Poie 1 Top Out - Heating Insulation lintel Final Sewer Fire Place /C �. Y✓ RE -.E,QR INSPECTION Pre Fab Mon. Tues. bVed. Thurs. Friday--- RM. A.M. Inspection Made _ r � P.M. ""Spector-- _— Fina! Inspection Certificate of Occupancy Date .--------- ---- -- �/-� _ //l3CITY OF fYtL K���.0 tB 04- Office of Building Official REQUEST FOR INSPECTION Date. f `_ Permit No. _ Time A. Received (-! _P. G—� b &,iLocality— Owner's Name Contractor BUILDING CONCRETE ELECTRICAL PLUMBING MECHANICAL Framing Rough Wiring C Rough ❑ Air Cond. & _ Re Roofing C Slab Temp Pole Top Out EHeating Insulation ❑ Lintel ❑ Final ❑ Sewer ❑ Fire Place C Pre Fab READ R INSPECTION .- A.M. Mon. Tues. Wed. Thurs. Friday A.M. Inspection Made " �.« f P.M. Inspector - _FinahnspectionY/- - Certificate of Occupaaeyr t `F Date CITY OF 14110 NI•.\IlNul F. k1111� t3lcck +s_ __.._SeotionS—st:.:a. «: � r• „i" ?�p`moi } ATt.t-*flt•lit V 11.Fi()klllt t._t� ... , tt TF.t.Fa'iil)�1;141111 247-:141N1 iT (�{ _}1+1 t l ('� i i .. • FAX 194"1 247.5804 :uDdIviUion : M i94 :ret 't ):ae+�• = � . DRIPTION OF WORK It in o FLgOD HA��1I7� Ir—C :vne:t_ _-_____creta complete page 3. Brief Descriptions_ Cle,tic of Mork: _ (Now/Remodel/Addition) ___•__ O)11NG INFORMATION Type of Constructions o;I s ng Proposed istr:.ct:---------Uses---------------------- Estimated Value g_- �vu T xceptions or Nsterislss__..... x................ ....... •rianCee Granteds------------------ lolid or ------------------------------------------ Filled Ground s CA •? Root s OWNER INFORMATXON it _ Method of Hastings__��+_� Property Ovners LrI -wK_-_ r�1=L- ----------- Phones_Z_� �- _ ---- Moiling _ - CONTRACTOR INFORMATION Contractors_ e+'� �� j j � `► ,t {� _ Phone: Mailing �? _ _ Address-__11$712 ._r'.L.'--"ht 1. Z•- -------------------- p: ? 7 -- — - -- t-----------'-�------ Zi �=------'-- - r Expire ion / License Number s---- �r--�3 —� .. ---------- Dates -9 f Y I NIRESY CRRTSfY THAT I MATS READ AND CKAMiR6D THIS APPLICATION AHD M14OM THC SAME m tt' AMD CORRECT. ALL ►ISOTISIONS of THE LAMS AND OIIDiNANCE5 OOVERNINO THIO. TYPE 6v vruar ' �J t CORPLIED MITN, MMSTHSR "CREW ON"CREOR NOOf•T. THE GRANTING A PERMIT VOL'; N-Ir rri' ~ ,.r GIVE AUTNORITY TO TIOL.AT6 OR CANCEL TNR PROVISIONS OP ANY FkUCRAL, STATE Ok LCn:At RCOULATION3, OMDiNANCP.S, OR LAMS IN ANY MANNER, IHCLUPIR0 THE GoVFR11INt1 or r•nusTR;-� Tu'•' PERFORMANCE Or CONITNUCTION or TNR PROJECT. I U1 OL"TAND THAT THE Is::UANCE OF ?,,I : r•. •* COIITIHOEIIT u►OH THE ASOVS INPORNATION SEIHO TRUE AND CORRECT AHO THAT THE PLAM. AkD r r•;•. DATA' HAVE BEEN OR SHALL SE PROVIDED AS REQUIRED. Ovner Signature lf ._ Lfn�rl� ,1!t -��'1- -.Uatc ' Contructor .e3lgnsturo_{ 1 `iw � - FYI?{ _��: ._...!)ate _�,� ..._.....__.r__ _._.. FLOODPLAIN DEVELOPMENT INFORMATION Type of Developments-------------------------------------------- Flood ,,---------..- -- --_--- Flood Zone;....................... Required Lowest Floor Elevations_______________ It building is located within a flood hazard zone, o survey mu"t be rude AFTER THE SLAB HAS BEEN POURED, certifying that the LOWEST FLOOR ELEVATION is equal to or above the base flood elevation established for that zone. No Sinal inspection will be wade and no certificate of occupancy will be issued until the survey is on tale with the Building Department. COMMENTS% Applicant Acknowledgements I understand that the issuance of thin permit is contingent upon the above information bei:icy correct and that the pians and supporting data have been or shall be provided as required, I agree to comply with all applicable provisions of Ordinance No. 25-7-11 and all other laws or ordinances affecting the proposed development. _-- <-1-1 Date-_w.___i__`... ___Applicant's Signature ----------------------------------------------------- Department -----------------------------. ------------ ---------Department Use Required Lowest Floor Elevation ................. As Built Lowest Floor Elevation ________________ Survey Filed with Building Department ........... Building-Department Represantativet pace 3 V4.& toot &sae MASS"Penn yis Its ttOs xo ���rtaC��rtf Weepo"w OUPWAAtw go bhm it a " I m a-pat : Tho undwsipwd hereby infbn vot A concerned that Improvements will be made to certain real property. and in acoordwm with section 713.13 of the Florida Statutes,, tlw following information is stated in this NOTICE OF COMMENCEMENT. of------ 1879 Beach Ave. Atlantic Beach, Fla. 32233 h►�W.CMN.N.NN...N..N.......N.........NN,N....N.N.....,.N........NN.....N.N...NN.....»..N.I,A...M.MrMN.NN.N.......... Lot 43 Block H North Atlantic Reach unit 2 N.........wNN .MN.....NNN......N....N....FNM/NM.M..MNN.NN..NN.YNNNYY.H..M.... _................» as recorded in Plat Book 15 Page 57 of the i1blic YN .N.... records of Dtsval County, Florida ............. NNNIMN.N ..N...»....... tisnersl Construction of a Garage 4- Ae4tt m-4–,-a-j NN.NN.NNU.... NN.NNN..yNN.Y.N.N.N.,.INN.MM.»wwNMM....N...w.N. ... ... ......w.• .N.MYWMNMI.wYMIN»...M.NNN..WN.IMYN,NNNIIMM YYN,NN.N»,....... ......... ... ..N.W.YN... WYNYNNNNw N..,N.N.NNNMYM.wMNN..NN..N.N.,.N..w».N....,..»». O, ......4ei.dunn B. Petrone w »� »». .. ..........NY.....MM......Y.F....Y...N..NN.N.N..N.MN..NN.MN NN.N..M.N ..N..N..N.......NNN..Yr..Y..NNNNNN..N.w.NN.......N.N..N.N........... 1879 Beach Ave. Atlantic Beach, Florida 32233 Aridray...._. .N. ...N.NNNN»»toot. »........N.....,. Ownwe s i is Bile of do Wpa i of Fee Simple .YNNMM.N.W...N.N.N....N.NN..NNN..YM.N.NNNNN.N NN.NNMNN.YN...... I" Swole Tide molder Of edger 6w swim) .. NNNNN».NN..N..Nw.........NN..wN.N.N..wNwwNN.N.NNNN.N.NYY.w.NN.w..N..NN.w Ad*ew197() Reach Ave.. Atlantic Beach, Florida 32233 Richard F. Carter �se�•N,..NNN. NMM»...NN .N....M..Y.NWwN....uNNM.W..........................N 1972 Beachside Ct-. Atlantic Beach, Florida 32233 YY.NNY.NN.NINN.NYNM.M.NM...YN... urMy o N/A w.». .N W MYN.N.NY.N.NM.NN.IM.Y.M W N N.NN IN N/A M.00 .YNNN. H6" of pwm wldia dr two of ii Wa AWp@W by weer Wes vAwe aolim or other&so ar my be Wv Reidunn B. Petroni AAA— . 1.879 Beach Ave. Atlantic Beach Florida 32233 .........w................ 1n&ddition1eMwmH.qwwduVaWdW0SN@Wh pst+sori is N Oak a tow of the lienors Notke as provided in Section 713.131 i! (Fl. FlorkM itemises. (FIN M st Owner's optlonj. 1dMM�••••••Y• wM,M.Nw..w Y..FM....N..M.NN.N.MN..N.N.N..N..»....Nw... CITY OF ATLANTIC BEACH, FLORIDA Approved by APPLICATION FOR ELECTRICAL PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE: + 19 IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. BILL THOmPSON E"ECRIC CO.,INC. P. 0. BOX 310I50 ATLANTIC B f ELECTRICAL FIRM: MAS ERLE TF(lCCIIiN ATURE JOURNEYMAN NAME ��T�/1 j� ADDRESS: IF-4n/ � /"�L • RFD BOX �._._,.._ BLDG.SIZE BETWEEN: RES.( ) APT.W COMM.( 1 PUBLIC ( ) INDUS. ( 1 NEW( ! OLD ( 1 REW. ( 1 ADDITION ( ) TRAILER ( 1 TEMP. ( 1 SIGNS ( 1 SQ. FT. SERVICE: NEW INCREASE ( 1 //0 REPAIR 1 ) FEE CONDUCTOR SIZE ��- AMPS / COPPER 1 1 ALUM. 2 /Z4 SWITCH OR BREAKER AMPS PH W VOLT RACEWAY EXIST.SERV.SIZE AMPS PH W VOLT RACEWAY FEEDERS NO. SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.80 AMPS, 81.100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPS. I OVER APPLIANCES r I I I BELL TRANSF. AIR H.P. RATING H.P. RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 0.1 OVER MOTORS H.P. VOLTAGE PHS NO. 1 H.P. VOLTAGE PHS MISCELLANEOUS CITY OF r�!�'a.�tic �eacl - ��Cvcid�t 800 SEMINOLE ROAD — —-- ATLANTIC BEACH,FLORIDA 32233-5445 TELEPHONE(904)247-5800 FAX(904)247-5805 Chapter 489, Florida Statutes,Part I 'CONSTRUCTION CONTRACTINO'requires Owner/Builder to acknowledge the law: DISCLOSURE STATEMENT for Section 489.103(`7),Florida Statutes: State law requires construction to be done by licensed contractors. You have applied for a permit under the exemption to Out law. The exemption allows you a the owner of your property,to act as your own contractor even though you do not have a license. Youmustimervise consUuctionyauml You may build or improve a one-family or two•faily residence or a farm outbuilding You may also build or improve a commercial building at a cost of$25,000 or less. The building rr Ud be€or your own utc and occupance. R may not be built for sale or lease. If you sell or lease more than one building you have built yourself within 1 year after the construction is complete,the law will preoxne that you built it for sale or lease,which is a violatioin of this exemption. You may not hire in iinficensed Berson as nu contractor. Your construction must be done according to building codes and zoning regulations. It is your responsibility to make sure that people=plgXed by vol have licenses re ur d by state lam and by C or m inidpal licensing ordinances. Ordinanws also allow an Ow wr to improve their own property when it is for personal or family use,and likewise require all work(except maintenanm under f2,004)be wider a building pernat and pass all normal inspechons. The ordinance states owners may physically do work themselves;or n=him unhwxud workers provided such workers be under "pct supervision of the owner,who must be an the- th site at all times while work is in progress by unlicensed trades people." ?his does not allow use efunlicensed contractors. Since owners W br liable pr i ' es to workers they hire,the Building Department suggests Workees Compensation insurance be purchased unless the homeowners insurance policy clearly protects the Owner. Owners hiring workers become employers and should also observe IRS withholding tax and/or Form 1099 requirements on the workers they employ on their improvement work j�licensed contractors caeeot be emolnved>j3dW env r_rirrimstisnees, Owners being subject to$5,000 penalty under Florida Statute No.455.228(1). An 8Oc X0i0nal License'is not adequate. The owner should physically seethe county'Certificate of Competency'or the Flocida'Contractor:Certificate'to ascertain if a person is a licensed contractor. Telephone the Building Deportment(247.5826)if in doubt. I hereby acknowledge that I have read and understand all the above on this -Zt) day of,�, 199 ��a 1-,J ���L 1 C ownerlBuilder J" SANDRA A.MACIAS MY COMMISSION N 441621 Address 2 z g EXPIRES:ES:ApApril 14,,1999 � 1 [ J B„\ Bonded Thru Notary Public Underwritars NOTE: Phrases underlined above U are emphasized by the Building Phone Department IDEN TION P r+ �t^+ r ►Cl°►2SL ��D /DID NO `TAKE AN OATH r f px 0 8.4 3 *4 DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH PERMIT I)±t>?�ORI�SAT I C)PI .�, -�,_,. .. LC}C'AT I ON I N FORMAT I ON --- erMit Number: 14843Address: ,1879 BEACH AVENUE Persalt Type: BUILDING ATLANTIC BEACH, FLORIDA 32233 lass of Work: REPAIR -- LEGAL DESCRIPTION ---------- Constr. Type: WOOD FRAME ot : -�43 Block: Section. _ . Proposed Use: SMILE, FAMILY Township: RNG: , 0 fs ellings : 1 Code: 4 ubdivi,sion: NORTH ATLANTIC BEACH timat4d value:Improv." Cast : $0.00 Total #e $9€x.00 Amount, $90.002-6-155 lark De IRS; REMOVE SIDING AND DAMAGED SHEA,THINO FICIN - _ APPLICATION LEES ---- Ka ERMIT $90.00 . ENUE VWATER PACT F 0 00 ddre�as�• 4 i ,f.= P� RADON GAS-H;R.S, $4 .Q0 �*°m C R A.TICI �_.. __ RADON CAB 5% $0.00 k Name: P` PE R CAPITAL IMPROVE. $0 .00, d SIKER CROSS CONNECTION $0 .00 censaf, Type: 1N SEC B IMPACTPER +' CONST.SURCHA:RGE $0 .0 met'+irw .5 NOTES. NOTICE--`ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS.WORT{MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER ,FAILURE TO COMPLY WITH THE MECH,�4NIV LIEN LAW .CAN RESULT IN HE PROPERTY OWNER FLAYING TWICE FOR THE BUILDING IMPROVEMENTS" IS EO°ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FORitIOLATiON t)F APPLICABLE PROVISIONS OF LAW. ATLANTIC B H BUILDING EPA M1;NT PA i By: .. OCT 2 5ti CITY OF ATLANTIC BEACH PERMIT ALCULATIONJEET Address 1�? 2,E e ��'��/�'s Lute 5 - 2 r Heated Square Footage @ $- per sq ft = Garage/Shed _(d $ per sq it = $ Carport/ Porch L @ S —_per sq ft = Deck Cd $ per sq ft Patio J� Op er sq f t _-- TOTAL VALUATION : $ AA T o t 1 valuation 1st �$,�4�2Q ----- S Remaining Value $_(- per thousand or portion thereof TOTAL BUILDING FEE $ + 11121 Filing Fee $ ( ) Fireplaces @ $15 . 00 BUILDING PERMIT FEE $ ,. WATER IMPACT FEE $_ C:� SEWER IMPACT FEE $ WATER METER/TAP S _. CAPITAL IMPROVEMENT SEWER TAP ( ) RADON (HRS) .0050 S_ SECTION H PAVING ( ) S HYDRAULIC SHARES S CROSS CONNECTION S ( ) SURCHARGE . 0050 S OTHER $ GRAND TOTAL DUE $ �� ' ADDITIONAL PERMITS OR FEES: Mechanical Plumbing _ Electric/New Electric/Temp ; SwimmingPool Septic Tank ; Well _ Sign Finish Floor Elevation Survey Other CALCULATIONS and/or NOTES : i t o -d,,i ani CITY OF ATLANTIC BEACH PERMIT APPLICATION REMODEL, ADDITIONS OR ALTERATIONS DEMOLITIONS owner(s) : Address:-N '79 . `�-� ... 1:, —Phone: Lot #-43 Block or Unit # Subdivision: Nc7r-ti"� A+10?� Contractor:' RP- ;c�-�� � �Ct� til ' �` State License # Address: 1979 a3 �� O-lk— W &�-- phone No:. 2 V-1 6 l 3 oet 5..c -rk to be done: Ex �ru� r� Lt,o ri-,C� 1"Z„�A.t+'S m o i� o{ oL S GS' - Sh.c.�t�w "T Present use of building:__` 4 L-N1rY1 �- Valuation of Proposed Construction: Proposed use: Is this an addition? If yes, what are the dimensions of the added space: ft. X ft. Will the added area be heated and cooled? New electrical (or increase)? New plumbing fixtures? New fireplace? New Heat/AC? SUBH=—T REE COMPLETE SE , Y , C CE ENT. AN R CONTR Signature OWNER:�Ie,Cctaw.✓4:?Z- m Date:. 9'�:� Signature CONTRACTOR: L d-torr- / Dp�e!': CPF ai6iQ6 L�A�ING &IONtNG License Supplied: � p �� ISO Liability Insurance: Worker's Compensation Insurance: n 1� \ _ f ✓ (� \ ' - JAJ0.T� w" Ox TREE REMOVAL SECTION A APPLICATION MUST BE RECEIVED BY NOON OF THE WEDNESDAY BEFORE THE MEETING: I. �sr,��,r,2�� �r> r c,� a ./,F.-7` • 01 nett NB11�19 i C !! p•"�'o'•� Telephony on Locattoa of Tr"R@nwM/SN.AlwNon SECTION B (To oonpleNd whom prope1h►N�e mdm*Mr K Mdude= SnWftftdrwrt� Nnotprraantyowner000u�pwd� l.Whet cha M aro paposad b ft bow gaorladSW 2.what N Oa pUMM oltltw p md c w%W 3•Spedly&M pgeedbr removal m 1 bW- TREE COUNT MO. scm(mx COMMON 4.wM these mesa ba robcated an tha mmpropW s.N eo+.wiN roplaoeRwt Mees be ptepled? . f s.spe*posed repbco by a n klowa: TREE COUNT SPECIE8 8tZE x } 7.Att'S .I site pian. i 1 i SECTION B - (All other Applicants) 1 . Property Zoning: 2. Submit the following: SITE PLAN/TREE SURVEY indicating: a) Site topography, existing and proposed grades b) Existing and proposed structures c) Location of all trees w/ DBH of six inches or more d) Tree species and sizes e) Trees to be removed should be clearly marked f) Trees to be relocated should be clearly marked g) Location of any proposed replacement trees h) Identify trees of special or unique characteristic i ) Identify trees within 10 feet of construction areas j ) Show location and type of tree protective barriers k) Location of utilities, accesses and easements. 1 ) Location of vehicle travel corridors m) Location of commercial sprinkler/irrigation systems n) Landscape maintenance plan (commercial only) o) Staging areas for equipment and material storage SECTION C I agree to comply with the rules and practices established in Chapter 23, Article II of the Code of Ordinances of Atlantic Beach. Owners Signature Date CITY USE ONLY Applicant has complied with all provisions of Chapter 23 and requirements of the Tree Conservation Board. Tree nservatip oard Des ee Diate NOTE: "Tree Protection for Builders and Developers" is available at City Hall or from the Division of Forestry , 8719 West Beaver Street, Jacksonville, FL. 32220. ( 781 -1434 ) i AddressQ `� t� —�--j-��--J ��'.�vac���f �.1 �. � Heated Squame Footage3.� }'� @ $ 53. per sq ft = $ 1 � Garage/Shed @ $ per sq ft = $ Carport/Porch @ $ per sq ft - $ Deck SS @ $ 0er sgft = $ Patio $ "----" per sq ft - $ TOTAL VALUATION: $ Total Valuation 1st $ ZO Rgnauider Valuation `_;. per thousand or portion thereof -------------------------------------------- Total Building Fee $ ADDITIONAL PERMITS and/or FEES REQUIRED + k Filing Fee $ Z= Mechanical ; ,2 Fireplaces @ 15.00 $ 3 p 0 f) Plumbing ✓ BUILDING PERMIT FEE $ Electric/New ------------------------------------------------- Electric/Tertp � , BUILDING PERMIT $ Septic Tank /� / �� •� �� Well WATER N= CHARGE $ Swimning Pool SEWER IMPACT FEE $ Sign WATER IMPACT FEE $ " �} Water Connection t PBS $ Sewer, Connection 'L-A )Yl 2 $ �J Water Meter J- Elevation Certificate GRAND TOTAL DUE -------------------------------------------------------------------------_ - �-- ----- CAL DATIONS and/or NOTES a Com K RECOMMENDED PROCEDURES TO FOLLOW TO USE THE STANDARD BUILDING CODE .❑ 1. Determine Occupancy Classification of the structure. Select occupancy classification which most accurately fits the use of the building. (Chapter 4) -❑ 2. Determine actual physical properties of building (a) Determine building area each floor. (Area definition Chapter 2) (b) Determine grade elevation for building. (Grade definition Chapter 2) (c) Determine building height in feet above grade (Height definition Chapter 2) (d) Determine building height in stories (Story definition Chapter 2) (e) Determine separation distance from exterior walls to assumed and common property lines. (Property line definition Chapter 2) (f) Determine percent of exterior openings per floor. 3. Determine minimum Type of Construction necessary to accommodate proposed structure. (Chapter 6) (a) Determine maximum allowable heights and floor areas for Types of Construction and Occupancy classification. (Table 400) (b) Check allowable height and area increases permitted. (Chapter 4) 4. Check detailed Occupancy requirements. (Chapter 4 and 5) Q 5. Check detailed Construction requirements. (a) Fire Protection of Structural Members (Chapter 6 and Table 600) (b) Fire Protection Requirements (Chapter 7 and Table 700) (c) Means of Egress Requirements (Chapter 11) (d) Special restrictions if in Fire District. (Chapter 30) ❑ 6. Review design as related to standards. (Chapter 12-20) ED 7. Check other requirements as necessary. (a) Use of public property (Chapter 22) (b) Elevators (Chapter 24) (c) Sprinklers, Standpipes and Alarm Systems (Chapter 9) (d) Use of Combustible Materials—Interior (704) (e) Roof coverings (706, 3002, Chapter 32) (f) Light, ventilation and sanitation (2001, 2002) (g) Other. These steps are naturally varied in sequence by individual preferences, however the first three are standard steps which should be followed in proper order to assist in design or review of buildings. Standard Building Code/101991 vii CITY OF ATLANTIC BEACH Fixture Unit Worksheet for Water Impact Fee FIXTURE UNITS ARE ESTABLISHED AS THE MEASUREMENT OF WATER DEMAND FOR EACH WATER FIXTURE UNIT INSTALLED AND CONNECTED TO THE CITY WATER SYSTEM. THE WATER SUPPLY CHARGE IS HEREBY FIXED AT TWENTY DOLLARS PER FIXTURE UNIT CONNECTED TO THE CITY WATER SYSTEM. r 3 BATHROOM GROUP CONSISTING OF SERVICE SINK TRAP STAND WATER CLOSET, LAVATORY & BATH (8) TUB OR SHOWER STALL (6) 1 ' WATER CLOSET _WATER CLOSET, TANK OPERATED (4) VALVE OPERATED (8) Q BATHTUB/SHOWER (2) URINAL WALL LIP (4) SHOWER GROUP PER HEAD (3) t1 FLOOR DRAIN (1) O SHOWER STALL DOMESTIC (2) _LAUNDRY TRAY (2) i LAVATORY (1) COMBINATION SINK AND TRAY (3) _WASHING MACHINE (3) POT, SCULLERY SINK (4) DISHWASHER (2) WASH SINK EACH SET OF FAUCETS (2) y KITCHEN SINK (2) 2' DENTAL LAVATORY (1) KITCHEN SINK WITH WASTE �7 DENTAL UNIT OR CUSPIDOR (1) GRINDER (3) } BIDET (3) !URINAL STALL, WASHOUT (4) COMBINATION SINK AND TRAY WITH TFLUSHING RIM SINK (8) —��FOOD DISPOS. (4) URINAL, PEDESTAL, SYPHON JET DRINKING FOUNTAIN (1/2) BLOWOUT (2):E / LAVATORY, BARBER/BEAUTY ICE MAKER (1/2) i a SHOP (2) SURGEONS SINK (3) LAVATORY, SURGEONS (2) j' V JACUZZI (2) V URINAL STALL, WASHOUT (4) TOTAL j FIXTURE UNITS �j � @ $20.00 EACH $ JOB INFORMATION_ t • A ' FL.00DPLAYN DBvNL.OPMNNT INFORMATION Type of Development%.._:. .. ` " ..-_--_....-...._-------------- Flood Zone a-_�_1. ,,,_..__........-........ Required Lowest Floor Elawation,_..I c-„�,-_-,� xf building is located within a flood hazard zone, a survey swat be wade AFTER THE SLAB HAS WEEN POURED, certifying that the LOWEST FLOOR ELEVATXON is equal to or above the baa flood elevation established for that sone. No final inspection will be made and no oert alcate of occupancy will be issued until the wurvey is on Ysie with the Building Department. • f COMMENTS: Applicant Aaknowiedgewent• Y understand that the issuance of this permit is coatinVent upon the above information being correct and that the plans and supporting data have been or shall = be provided as required& t sgsee to comply with all applicabioe i provisions of Ordinance Xo. 25-7-11 and all other laws or ordinances affecting the proposed development. Date Z� .;. _._...APP1Acant•s Signaturo„✓ _ _�/cc� C rG Depurtsent Use equired Lowest Floor Elevation _------ Built Lowest Floor Elevation _..,..,..--r--_------ urvey Filed with Building Department ----------- ---------------- __--_-_ rr..rr-.r.►rrr r...r.r-r-------ri----_rr- 6uilding Department ,Representstive t A. page 3 5349 DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH ----- PERMIT, INFORMATION - LOCATION INFORMATION -- + Number t 5349 Addrema t 1879 BEACH AVENUE I r tat Type% MECHANICAL, ATLANTIC BEACH,, FLORIDA 32233 6 CI twa of Work: NEW LEGAL DESCRIPTION C+D aEttir. ---------- Type: WOOD FRAME Lots Block': Section: ',. Proposed Us z SINGLE FAMILY Towns hip: RNG a Ov*llingsa 1 Codes d SubdivisiOni MORTH ATLANTIC BEACH `Ii'su' "Doted Valuer 80. 00 Improv. Cost: $0.00 Tot '. $73.'00 i *^ _� ATION APPLICATION FEES PERMIT $73.00 # AVENUE W I"PAC,T F'EEffl""""` $O O a we a'� i7ky � �F 1.�. d> �'` .Y" � � raa,: r.°OR RsFE POT' �. 3 , s ' ✓33 P k: WA 1 C.O1a ,. RADON GAS-H. R. S. $0. 00 OR NF"ORMAT AI .� _ RADON GAS 54. tJ0 FxAT 3 .IIx_,k lot-D4` SEWER TAPWATER TAP $0. 00 Adx C1. 4(3 HYDRAULIC SHARE $0. 00 t � TYP fl RE-INSPECT FEESO.,00 OTHER #I : Llirc . .k `:NOTES; NOTICE—ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE U#LD NG NIATERIAI.,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED U!IP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER. "P LURE TO COMPLY WITH THE MECHANIC' LIEN LAW CAN RESULT IN TSE PROPERTY OWNER PAYING TWICE FOR BUILOtNC 'IMPROVEMENTS." VXINTIPN DAM 05/11/92 . fi ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT` BJECT Tod CATION FOR Vt :A tf�KOF-APPLICABLE PROVISIONS OF LAW, COO 0 497 ATLANTIC BEACH BUILDING,DEPARTMENT BUILDING AND ZONING INSPECTION DIVISION CITY OF ATLANTIC BEACH ATLANTIC BRACH. FLORIDA 32233 APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER IMPORTANT� Applicant to complete all items in sections I. 11. 111. and IV. 1 __ LOCATION Stat Add»s+:OF Intersecting shah: Between 4 f�� cam' � And �- BUILDING Sub•s(ivision 11. IDENTIFICATION — To be completed by all applicants In consideration of permit given for doing the work as described in the abcve statement we hereby agree to perfo•mn said ..ort with the attached plans and specifications which are a pert hereof and in accordance with 'he Gty of Jac►sonvd'e ordinances am* 1,6-ae•vs of good practice listed therein. Name of Mechanical c 1 Contractors Contractor (hint) )�j�,� 1 :V r �- ;/ Matter ( Name of Property 0w6N Sigaeture of Ower Signature of er AeNta4*4 Ag•at r' Arehihe/ or Eegineer Ill. S&O AL INFORMATION A. Type of Mating fisel: B' O , Ili OTHER CONSTRUCTION OEING DONE F1gc� THIS BUILDING OR 31 TE f cis Q "—(3 V O Natural O Centro)Utility IF vesr GIVE NUMKF,I, I (CONSTRUCTION 0 09 PERMIT � c�� "1 . Q Other -- SP041y IV, M@CNAMICAL MuirMINT INT TO N INSTAt1RD NATURE OF WORK jr,evide complete Fid of compo -its on bad of this farad A Residential or [] Commercial v" Nut (3 Space E3 ReassW ,# Central O Floor / New Building Ai►Colyddiening: 0 Rom )1 Control ( � D Existing Building a MCI"" ❑ Replacement of existing system putt System.- Material. Mad soMsst eepeeity s�,��UZ�.�.__s.f agNaw Installation(No system previously installed) ❑ Extension or add-on to existing system Q Refrigeration ❑ other— specify Q Cooliag fewer: Capacity g QFin songeft: Nember of L—A. ....-...... -�---_ Q Bmfw Q McAft O Escald THIS SFACi POR OFFICE UN ONLY Q Gogeliiae P46— Took- 0 Took-O LG (ewnber! Q WrCw/"e"to vows tali) Approved by Deb O ietMsa Q 00W... k hnnit F-� LIST ALL EQUIPMENT AIR CONDITIONING AND REFRIGERATION FQVIPMENT cay lty Appravhg 01 c )number ua to Dererfptim MOM Number Manufacturer Nona) ASSUCy zI p(' 1 y. 3(`- tt hAfir- 5 .55 DEPARTMENT OF BUI'L0t*Q CITY OF"ATLANTIC BEACH - PERMIT INFORMATION --- LOCATION INFORMATION --------- - Perm - P'erm t Number. 5158 Addr°eas x x 879 BRACH AVENUE Permit Type: PLUMBING ATLANTIC BEACH, ,FLORIDA 32233 C1aas of Wo rk% NEW �- LEGAL DESCRIPTION Conxtr. Types WOOD FRAME Lot: Flock Section Proposed Uses SINGLE FAMILY Township: RNG: 0 Dwellings- 1 Codes 0 Subdivivl:.Lon gatiasted Values #0.00 Improv. Casts $0.00 Total 1` + '84 $74. 50 Amour „, $74. 50 Diet 4/ 152 work MBING IN NEW RESIDENCE -.._�.... _ ATION -_-- APPLICATION FEES .P, PERMIT $74.50 Addx�e°I�iss; AVENUE WATER IMPACT FEE $0.00 I H, P'LORID�� °�E PEE av- O+l m. _af' aa" aF'hg'�`ta {M, '"tirrc'k.. A '' RADON GAS-H. R. S. :$0.00 ...'. _-- R Q P'OR1 ATI H - RADON OAS - 5% $0. 00 Dame 3 LEM G WATER TAP $0. 00 ,. 'PREEN" a�,.. ..,... .M� �. SEWER' ''1`AP ;�� $0* 00 � .TACK LLE, FL. 32210 HYDRAULIC SHARE $0.00 LIr ' rype 0, RE-INSPECT FEE 00 SEC. H IMPACT FEE $0.00 NOTES; NOTICE-ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILC INC'IMPROVEMENTS." ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUET TO RE OA iIIOLATION OF-APPLICABLE ICABLE P14OVISIONS OF LAW. 79Km I174. 0 RECEIPT MAW; 05m ATLANTIC BEACH BUILDING DEPARTMENT 77 c x CITY OF ATLANTIC BEACH APPLICATION FOR PLUMBING PERMIT JOB LOCATION: I ?17 PLUMBING CONTRACTOR: Rum (3)tuQ' LICENSE NUMBER:_. D �J Jl) hSw VJ4�_ ��� OWNER: BUILDING CONTRACTOR: LE STF-0 V0uRA(?j}< TYPE OF BUILDING: SINKS SHOWERS 5 LAVATORY F WATER HEATERS BATH TUBS DISHWASHERS URINALS DISPOSALS CLOSETS I` WASHING MACHINE FLOOR DRAINS OTHER TOTAL FIXTURE COUNT: 17 + $15.00 . --------------------------------------------------------------------------- INSTALLATION ON PLUMBING AND FIXTURES MUST BE IN ACCORDANCE WITH THE MOST r RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE. DATE: PRE-SERVICE DIVISION JACKSONVILLE ELECTRIC AUTHORITY 233 WEST DUVAL STREET JACKSONVILLE, FLORIDA 32202 THE FOLLOWING FINAL INSPEGTION(S) HAVE BEEN MADE AND ARE SATISFACTORY: V � t X. ---- ------------------------------------------------- -_ ___ _________________________________________________ ------------------------------------------------1 ------------------------------------------------ ------ 1-------------------------------------------------- SINCERELY, BUILDING INSPECTION DIVISION cc:FILE CITY OF ATLANTIC BEACH, FLORIDA ADProwd DY APPLICATION FOR ELECTRICAL PERMIT a TO THE CHIEF ELECTRICAL INSPECTOR: DATE: a� < ` 19� IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID VVORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. c tC ELECTRICAL FIRM: ASTER ELECTRICIAN SIGNATURE JOURNEYMAN NAME d •-PAAX L atktx-0-42 � ADDRESS: g 79 RFD-----BOX- BLDG. FD BOXBLDG.SIZE ll� )14lg- BETWEEN: 4, L4 2- J 41 S� RES.( ) APT.( ) COMM.( ► PUBLIC( 1 INDUS.( 1 NEW( OLD( ) REW.; ADDITION( ) TRAILER ( ) TEMP.i SIGNS ( 1 SO.FT. SERVICE: NEW X► INCREASE( 1 REPAIR ( 1 FEE CONDUCTOR SIZE AMPS COttPyyPERr ALUM. SWITCH OR BREAKER D AMPS PH 3W 1 a/-4b oLT RACEWAY EXIST.SERV.SIZE AMPS PH W VOLT RACEWAY FEEDERS NO. SIZE IND. SIZE NO. SIZE UGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.90 AMPS. 91.100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPS. CVBR APPLIANCES BELL TRANSF. AIR H.P.RATING H.P.,RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS ICEIL HEAT: KW-HEAT 0.1 OVER MOTORS H.P. VOLTAGE PHS NO. 1 H.P. VOLTAGE PHS MISCELLANEOUS tee.�ul.rA nurnn- .Iu/1rs CMV A\/CO CM\/ J TRANSMITTAL DDOCUMENT FOR J13A DATE.. The following permits have passed "rough" inspection: Permit No. Address 6z( / Enclosed are our (blue) copies of the permits. Please update your records accordingly. Thank you, NG CLER i CITY F AT TIC BEACH /vcb FLA.1977 LAWS 2o, VOL7351 M265 RAMCO DORM 409 FS 713.19 IWAL 11" N atirr of ,jamrrrr 1►RKPARt IN OU►LICAY[I W4= t# rug rout= The undersigned hereby informs all concerned that improvements will be made to certain real property, and in accordance with section 713,13 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description.o.f. property-(inTccllu�de Street Address. if available) ...........................:................. 14AlTG !CtFr.Q. :.. „ .............:....... ................................................. h ............J.. .7. .. 13 �ci�.. ..................................... ........... ........I General description of improvements .................................................... JUN 2 .1992....... ......I................ ....4 use,.:.......................... ............Bui.0 g..*. Zoning, ................................................................................... ................................ Owner ..... e44i2,'A... f�� ,t?z?N.(........................................................................ Address1! !YI.(...f". ...-x. Oc7S�............................................. d Owner's interest in site of the improvement ....... ....................................................... Fee Simple Title holder (if other than owner) Name ................ )N.1�...................................................................................... Address .......................................................................................................... Contractor ..... -77oc................................................... Address .......P.:.P.:. ...... !!�y /Ceu�JCC... / ... ��r� ......................... ........ Surety(if any) ......... jlT.. ......................................................................... Address ....................................................................... Amount of bond$ r-- ............... C ; Any person making a loan forthe construction of the improvements: Nerve .....1...-r� (f'1.z-.F,�. vs.#..cJ.carL4hcg,4?AP _1I lz.a�'........................................ . `Address ....9 � ... n?�+4�?ut?�... ... .KSoUv1 t l �.A .......................... Peron within the State of Florida designated by owner upon whom notices or other documents may be served: c Address .......................................................................................................... In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713..13 (1) (h), Florida Statutes. (Fill in at Owner's option). Name ...............W! ....................................................................................... Address ................................................... - r. _ THIS SPACE FOR RECORDER'S USE ONLY I FLA. 1877 LAWS RAMCO FORM 409 FS 711.13 Natio'cr of (faintururrinent t►RL►ARL IN DU►LICAT[I vyu fuh,Oxtt it Utp tDY[Cem The undersigned hereby informs all concerned that improvements will be made to certain real property. and in accordance with section 713.13 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property (include Street Address, if available) ../........................................... ........... 4. ...`� .. !`h:(, 1.4A�T�c L��?AGtiN�t TLv off.. 1 V4�...................... ........... - . ....... ......................................................................... ............ q.. .-Av.. -..................................................................... General description of improvements ............................................................................. ........... .......... CT(,5....................................................................... ................................................................................................................... Owner .....4. E tl►' ?... ............................................................I........... Address ...APu 1. .,-)x../S.."......A+ .i...F!...- C�C�SJ............................................. 0 Owner's interest in site of the improvement .......�Unjx ...................................................... Fee Simple Title holder (if other then owner) Name .................AVA................................................................ I......... I......... .. Address ........................................1. ................................................................ Contractor.....4 .0..•.�Qu�;e���'t�..�l��/.�?'�a�s..-4i)e................................................... Address ......!:P. ........ ...�/! ... '1.................................... Surety(if any) ............ lfi.. ..........................................................:................... Address ....................................................................... Amount of bond S ............... Any person making a loan fortheconstruction of the improvements: Name .....0 I f1.z-�F S.#..rJ ���°�^�?..�?P.�' a�.C--E? '........................................ Address ....9.: ........ �'-! �?r?u?$...!`� ?... .K S t?Uvl�� ... �.!�........................... Person within the State of FAlorida designated by owner upon whom notices or other documents may be served: Name ................ [A.............................................................................I........ Address .......................................................................................................... In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713..13 (1) (h). Florida Statutes. (Fill in at Owner's option). Name ...............��fa................................................................I..............I........ i re 0 ffm . 7500 , DEPARTMENT OIC BUILDING CITY OF ATLANTIC BEACH .» EFIMIT; INFORMATION __ _-- LOCATION INFORMATIOft Rumbe 7500 ___y-i- y� (yy'��yy y�/�' _�.� . __. .,_ Address . x.879 BEACH AVENUE P x it it BUILDINCI ATLANTIC BEACH, FLORIDA 32233' at$$ of Nark: ADDITION LEGAL DESCRIPTION fi Crs tr. Type: WOOD FRAME Leat'yr4�w_ Black. Section � 'r pose Use: PATIO/DECK Township RNG: 0 D 1 ags 1 Codes;: O subdivision: NORTH ATLANTIC BEACHBetted Vslue, $$00 .00 Improv. Gest : 0 :O""''j0 70P -fou $22.50 $22 .s �N'fr*.wyr n+..-.. `r•` , "' ' t,t?rdA.�WS AlIONt.--- APPLICATION FEES N14 PETROPI „ PERMIT $22 . 50 kAd i E” AVENUE WA IMPiAP FEE so .00 4. 1 �y I H, PLORID � 4' { " rrr . tJ �e . » . . .. RADON OAS-H.R. S, $0 .00 4 FORMAT;, N RADON CTAS - 5% $0.00 1 ROP O ER .. CAPITAL. IMPROVE. -so .oe .. . SEWED TAP as0.110 HYDRAULIC SHARE $0.00 Type, I CROSS CONNECTION 0 j µ SEC.'H IMPACT FEECON.71 I fp i 1 j NOTICE—ALL CONCRETE`FORMS AND FOOTINGS MUST 13E 1,MSPECTE6 BEFORE POURING PERMIT VOID SIX MONTHSAFTER DATE SOF ISSUE 11iIL,C3#I+t a MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEAR;E J)UP AND HAULED-AWAY SY EITHER CONTRACTOR OR OWNER " AI LURE TO COMPLY WITH THE MECHANICS' LIENL�►W AN RESULT IN � !ROPERTY �1►NER RAYING 'T11M1'ICE FOR BUILDING IMP OVEMENTS " { #SSUI5Iy ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERM IT:AN BJECT fft ION FOR OF`APPLICABLE PROVtSIONS OF LAW. ` TIM ATIANTTO.EA BUILDING DEPARTMENT 6ECEIPT mmos. 131162 CITY OF ATLArJTF.0 ­,TnDC111 r-MUIXT Cr'�7,,IULZITIOW SHMET Address-11 Date—-., Heated Square Footage er sq ft = Garage/Shed --per sq ft = $ OV-7— Carport/Porch er sq ft = $ Deck per sq ft = Patio v per sq ft = $ TOTAL VALUATION: $ Total Valuation 1st $ Remaining Value $ per thousand or portion thereof TOTAL BUILDING FEE + 1/2 Filing Fee $ Fireplaces @ $15 .00 $ BUILDING PERMIT FEE $ WATER IMPACT FEE $ SEWER IMPACT FEE $ WATER METER/TAP $ CAPITAL IMPROVEMENT $ NEWER TAP $ RADON (HRS) .0045 $ RADON (CAB) .0005 $ SECTION H PAVING $ HYDRAULIC SHARES $ CROSS CONNECTION $ ( ) SURCHARGE .0050 OTHER GRAND TOTAL DUE $ Z- ADDITIONAL PERMITS OR FEES: Mechanical_; Plumbing Electric/New Electric/Temp,_;SwimmingPool Septic Tank Well Sign_Finish Floor Elevation Survey other CALCULATIONS and/or NOTES: CT 2 81993 CITY OF ATLANTIC BEACH Building and Zoning PERMIT APPLICATION REMODEL, ADDITIONS OR ALTERATIONS DEMOLITIONS Owners) 7f tc Address : 1�?172'�- _Phone: Lot # Block or Unit # SubdivisionC,17L– Contractor:- © 2 Address : Phone No: Describe work to be done: r1�S/ `' ?C/C��r�l' C ' TO S 30 �e � e7 &MQ Present use of building: Valuation of Proposed Construction: Proposed use: /Z Is this an addition? -� If yes , what are the dimensions of the added space: 'ft . Xft . Will the added area be heated and cooled? /(/ New electrical (or increase)? New plumbing fixtures?A2-6 New fireplace b New Heat/AC? v SUBMIT THREE COMPLETE SETS OF PLANS, INCLUDING SITE PLAN, SURVEY , ENERGY CODE FORMS, NOTICE OF COMMENCEMENT , AND OWNER/CONTRACTOR AFFIDAVIT, IF OWNE S CONTRA R. Signature NER: Date: 2� 93� Signature C To Date: P P R PNS\o� cF�o� 0 ey FLORIDA DEPARTMENT OF NATURAL RESOURCES Division of Beaches and Shores Permit Number:_ 004786 1)tl Swam of Coastal Engineering and Regulation 3900 Commonwealth Blvd. - M.S. 310 No. of Pages Attached: Tallahassee, Florida 32399-3000 FIELD PERMIT APPROVED PURSUANT TO SECTION 161.033 or 161.052,FLORIDA STATUTES FINDINGS OF FACT: An application for authorization to conduct the activity indicated in the location and project description shown below was filed with the Department on the date shown above. CONCLUSIONS OF LAW: The application was considered by the designee of the Director of the Division of Beaches and Shores, was found to be in compliance with the rreegqw�rements of Section 16B-33.007 Florida Administrative Code (F.A.C.) and was approved pursuant to authority subdeleNated in Administrative Directive W& 140. Approval is specifically limited to activity in the stated location and prglect description and the approved lens (iFany),and not rohibited by the conditions provided in Section 16B-33.015,F.A.C.,or any additional conditions stated below pursuant to RiSe 16B-33.015(3)(u),F.A.C. The specific subdelegations of authority exercised by the staff designee are: I, BS-5 ( .S') PROJECT LOCATION: /e)U /— 1 Sd / �Uh 7 (DNR R. monument & st. add Mas PROJECT DESCRIPTION: d Z /`oo 4�1 P C' Ye A 7'r d x, '.r v.� �� ��,D rP /74h-,a / �✓_-�_ti�a -- -r���i�d//r SPECIAL PERMIT CONDITIONS: This permit is valid only after all applicable federal,state,and local permits are obtained and does not authorize contravention of local setback requiretietts or zoning or building codes. This permit shall be posted on the site as Public Notice immediately u its date of issuance, and shall remain posted along with local approval until the completion of any activity authorized by this permit. Other specie!conditions of this permit include: ✓ e e 0,1 APPLICANT 94FORMATION: I hereby,certify that: (1) I on either tate owner of the subject property or have the owner's consent to secure this permit on the owners ; shell obtain any aplicable licenses or its which may be required by federal, state, or municipal Is rior to encenenIt ofpflie authorized work; (3) I acknowledge that the authorized work * -ha ; an ' 'stv for compliance with with all permit conditions. Signa ate J1 ZR Telephone No. d ) a W-6 /1 >._ e4 Printed Nam . Iso Title&,pCompany Name if applica b / Mailing Address � ! �y/ BPc+�C� DEPARTMENT FINAL ACTION: This permit application was approved on behalf of the Department of Natural Resources, Division of Beaches & Shores, and the Public Notice was posted by r (staff'designee): ,on Date The permit expires 24 mo after issuance upon such earlier date as is hereinafter specified by the staff designee. EXPIRATION DATE: 7 Approved plans are attached: YES [ ] NO�(]. Section 161.015 F A.C. ( Permit ondi o was provided to the applicant: YES NO [ ]. This permit is a not ( ] valid without a Departiesf "Intareation Forte Old Reduce Impacts to Marii,e The Sea Turtle Program and Local Au were notified on (date in office): PUBLIC NOTICE: The foregoing constitutes final agency action. Any person substantially affected by this determination has then' lit to request an admints` trative hearing to W conducted in accordance with the provisions of Section 120.57 Florida Statutes N.S.). Wuldyou desire an administrative hearing your reguest must comply with the provisions of Rule A-5.201, F.A.C., if requesting a formal administrative bearing, or Me 20-5.5®1 F.A.C.,if requesting an informal hearing. Requests for hearings must be received by the Office of the Umal Counsel ate the Departatent s mailing address as written above, within twenty-one ZI days after the date Obis notice Failure to respond within this allotted time frame shall be deemed a waiver c all rights to an administrative the event that a legally-sufficient time�_lyy received,jou have the ' lit to �' y petition for a ng is not ��_�yyyy y r� judicial i+e�riev► i� the t parstwnE to Section 120.68, F.S. and Rules 9.03�(1)(c)and 5.110,Florida Rules of fpellate To ini as the Notice of Appeal must 6 riled with the ice of General Counsel and with the appropriate of A wititin thirty (30) ps after this notice was posted. The Notice filed with the District Court most be by at fee sped r m u on 35.22(3), F.S. DNR Form 73-122 (Rev. 11/91) [White Copy-Tallahassee Office] [Yellow Copy-Applicant] [Pink Copy-Staff Designee] 1 . OW14ER BUILDER PERMIT AFFIDAVIT-�!�' 3t�.tr' of Florida I City cif Atlantic 8•actg //�� BEFORE }}� the undersigned authority, _ --E-"¢� %�c� Y. peracnally ipt+varrd �___ who upon first b.*ing duty sworn, deposes and saysi I• /`Z�'2'��� / - and the legal owner-cif the following propertyt -r------ , Subdivision Block .4:�dlT_I Lots AKA ------,.- I am applying for w building permit pursuant to chv Owner Builder exemption set forth in Florida Statute, Section 489. 107. Florida law requires that Z have been provld&d with ttj& tollowing DISCLOSURE STATEMENT i DISCLOSURE STATEMENT -State lav requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law, The exemption allows you, as the owner of your property* to ,act as your own contractor even though you do not have a license. You must supervise the construction yourself, You may build or Improve a one " or two family residence c.r a farm outbuilding. You may also build or Improv• a commercial building at a cost of 023,000, 00 or less. The building Must be for your use and occupancy, it may not be built for sale or lease. If you sell or leabg more . than one building you have built yourself within one year after the construction is complete, the law will presume that you built it for sale or lease, which in a violation of this exemption, Your construction must be done according to building codes and zoning regulations, It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. I hereby acknowledge that I have read the above DISCLOSURE STATEMENT and that I comply with all the requirements r the issuance of an Owner-Builder permit# Further, affiant zayeth not. Pr perty Owner Sworn'. to and subscribed b• • hi ��_ day • " "_ a • { y , u O 1 0003 .t A14 ' 0 r _ I Y- r n4 1 <�. .rtxss�rs i ..��•.-r-+tom�: ~"-�.=�' i 7��.''�'�`�� i dL oF :lr7v 49 TNtr S '57 � 7 ✓ v Z r-; Oo D 0 T-Ul 'on fLlj I D E: 6 OwN 5"a 0 Jodear"*. Flafft 3M 0 904.384'15$9 k AxW Eidwr ,Asr, F.A.D.A. f ; 0' a i rt.; }i 4• r � 4 ��� f �� i1 iii.� =i(} �+� • • _. CITY OF ATLANTI" REACT BUILDING OFFrIcE SEP 2 81993 _ D 1,, 49 e A w 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 900-A-91 Section 9—Residential Point System Method Climate Zones Department of Community Affairs NORTH 1 2 PROJECT NAME A ' AJ l BUILDER: AND ADDRESS: r rc +°-- PERMITTING CLIMATE 1 ❑ 2 ❑ 3 OFFICE: ZONE: PERMIT JURISDICTION t OWNER: ��°,412D �Pdil A NO.: NO.: V? ! Q NEW CONSTRUCTION ® IF MULTIFAMILY,NUMBER OF CONDITIONED - so. GLASS AREA AND TYPE UNITS COVERED BY FLOOR AREA73[�f_ CLEAR TINT,FILM,SOLAR SCREEN ADDITION ❑ THIS SUBMITTAL: PREDOMINANT SINGLE- SD. SINGLE- EAVE OVERHANG SD. MULTIFAMILY ATTACHED ❑ CHECK IF THIS SUBMITTAL LENGTH �•� FT PANE ��FT. PANE FT. REPRESENTS A WORST CASE PORCH OVERHANG •� DOUBLE- SO, DOUBLE-I I _1_J SO. LENGTH F SINGLE-FAMILY DETACHED CONDITION: ❑ T. PANE FT. PANE FT NET WALL AREA AND INSULATION EXTERIOR MASONRY R = EXTERIOR FRAME R = EXTERIOR STEEL R = EXTERIOR LOG R = -21 FO. ® .Fol I I L FT E 1 E so.FT [T] �F°: m ADJACENT MASONRY R = ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R I = �� FT [11 .❑ FT m FT m FT m CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION UNDER ATTIC R = SINGLE ASSEMBLY R = SLAB PERIMETERR = RAISED:WD CON❑ R = ' FO. -S O FO. ❑ r �If FT. 1441 FO. DUCTS COOLING SYSTEM HEATING SYSTEM HVAC CREDITS HOT WATER SYSTEM7RECOVERY,c.,m EDITS IN CENTRAL ❑ ELECTRIC STRIP ® HEAT ® CEILING FANS ELECTRIC ,m UNCONDITIONED PUMP SPACE R = ❑ ROOM ❑ NATURAL GAS ❑ CROSS VENTILATION ❑ NATURAL GAS I 10I•� ❑ PACKAGE TERMINAL ❑ ROOM UNIT OR OTHER ❑WHOLE HOUSE FAN ❑ OTHER FUELSAIR CONDITIONER PACKAGE TERMINALFUELS D IN CONDITIONED HEAT PUMP ❑ NONE ❑ ATTIC RADIANT ❑ NONE HEAT PUMP: ❑ .0]SPACE R = El NONE BARRIER E.F. _ �•❑ NUMBER O SEER/EER = AFOUECP/HSPFI �.� El MULTIZONE EF = BEDROOMSF = INFILTRATION PRACTICE USED _ X 1� — ®, ❑ #1 •171 #2 ❑ #3 TOTAL AS-BUILT POINTS TOTAL BASE POINTS CALCULATED E.P.I. CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. I hereby certify that the plans and specifications covered by the calculation are in compliance with the Review of plans and specifications covered by this calculation i icates compliance with Florida Energy Code. the Florida Energy Code. Bet o co truction is leted,t ' l will be inspected for compliance in accordance ith Se ion 553.9T, .S. PREPARED BY: LC/' `� �-� DATE: Z—�-'9 BUILDING OFFICIAL: �^ I hereby certify that this building ,is in compliance wi the Florida Energy Code. OWNER AGENT: fJl l/ �L"_ DATE: 2`�3 cl'2- DATE: 9A I PRESCRIPTIVE MEASURES(must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK WINDOWS 904.1 Maximum of 0.34 CFM per linear foot of operable sash crack includes sliding lass doors). EXTERIOR& 904.1 Maximum of 0.5 CFM per sq.ft.of door area:solid core,wood panel,insulated or glass doors only. ADJACENT DOORS EXTERIOR JOINTS 904.1 To be caulked,gasketed,weatherstripped or otherwise sealed. &CRACKS WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A, Switch or clearly marked circuit breaker(electric) v or cutoff as must be provided. External or built-in heat trap required. SWIMMING POOLS 904.3 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a N j &SPAS um timer.Gass a&pool heaters must have minimum thermal efficient of 78%. /A SHOWER HEADS 904.5 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG. V' HVAC DUCT 904.6 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached, CONSTRUCTION, sealed,insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned INSULATION space and air handlers located in attics must be insulated to a minimum R-42(R-6 after 1/1/92). &INSTALLATION HVAC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system. INSULATION 904.9 Ceilings Min. R-1 9. Common Walls Frame R-11 or CBS R-3. Common Ceilings&Floors R-1 1. ✓ -1 - 91 HEATING SYSTEM MULTIPLIERS(HSM) CLIMATE ZONES 1 2 3 SYSTEM TYPE EATING SYSTEM MULTIPLIERS Central Heat HSPF 6.4-6.79 6.8-6.89 (6.9-7,391 7.4-7.89 1 7.9-8.39 8.4-8.89 8.9-9.39 9.4-9.89 Pump Units HSM .53 .50 .49 .46 .43 .41 .38 .36 HSPF 9.9-10.39 10.4-10.69 10.9-11.39 11.4-11.89 11.9-12.39 12.4&U HSM .34 .33 .31 .30 .29 .28 PTHP COP 2.6-2.69 2.7-2.89 2.9-3.09 3.10-3.29 3.30-3.49 3.50-3.69 3.70-3.89 3.90-4.19 HSM .38 .37 .34 1 .32 .30 .29 .27 .26 Electric Strip 1.0 Gas&Other Fuels 1.0 See Table 9J for Credit Multiplier) 1991 Minimums: Central Units-Air Source 6.4 HSPF,Water Source 3.4 COP,Ground Water Source 3.2 COP,PTHP 2.6 COP. 1992 Minimums: Central Units-Air Source 6.8 HSPF,Water Source 3.8 COP,Ground Water Source 3.4 COP,PTHP 2.7 COP. HSPF means Heating Seasonal Performance Factor. COP means Coefficient of Performance. 9J HEATING CREDIT MULTIPLIERS HCM SYSTEM TYPE HEATING CREDIT MULTIPLIERS Attic Radiant Barrier HCM 98 Multizone HCM .90 Natural Gas AFUE .68•.72 .73-.77 1 . -.82 HCM .52 .48 .45 42 .40 .38 Other Fuels HCM .65 .64 .59 .56 .43 .50 Where more than one credit is claimed,multiply RCM's together. Enter product on page 4.AFUE means Annual Fuel Utilization Efficiency. 9K COOLING SYSTEM MULTIPLIERS CSM SYSTEM TYPE COOLING SYSTEM MUTIPLIERS RATING 7.5- 8.0- 8.5 8.9 9.5 10.0 10.5- 11.0- 11.5- 12.0- CENTRAL UNITS 7.9 8.4 8.8 9.4 9.9 10.4 10.9 11.4 11.9 12.4 (SEER) CSM .45 .43 .40 .38 .36 .34 .32 .31 .30 .28 PTAC&ROOM UNITS RATING 12.5- 13.0- 13.5- 14;0- 14.5- 15.0- 15.5- 16.0- 16.5- 17.0- 17.5 (EER) 12.9 13.4 13.9 14.4 14.9 15.4 15.9 16.4 16.9 17.4 &U CSM .27 .26 .25 .24 .24 .23 .22 .21 .21 .20 .19 1991 Minimums:Central Units-Air Cooled 8.9 SEER.Ground Water Cooled 10.0 EER.1992 Minimums:Central Units-Air Cooled 10.0 SEER.Ground Water Cooled 11.0 EER. FTAC-see Table 9-11A. EER means Energy Efficiency Ratio.SEER means Seasonal Energy Efficiency Ratio. 9L COOLING CREDIT MULTIPLIERS CCM SYSTEM TYPE COOLING CREDIT LTIPLIERS CCM CeilingFans .86 Multizone .90 Cross Ventilation or Whole House Fan(Credit for only one) •95 Attic Radiant Barrier .95 Where more than one credit is claimed,multiply CCM's together. Enter product on page 2. 9M HOT WATER MULTIPLIERS HWM SYSTEM TYPE HOT WATER MULTMIM Electric EF .80-811.81 .82•.83 .84-.85 .86-87.87 .88-.90 .91-.93 .94-.96 .97&U Resistance HWM 4183 4081 3984 3891 3803 3678 3560 3450 EF .43-.47 .48-.49 .50-.51 .52-.53 .54-.55 .56-.57 .58-.59 .60-.61 .62-.63 .64-.65 .66&U Natural Gas HWM 2732 2448 2350 2259 2176 2098 2026 1958 1895 1836 1780 Other Fuels HWM 2121 2368 2467 2566 1 2665 2570 1 2481 2398 2321 2248 2180 Water heaters must comply with minimum efficiences in Table 9-7A of the Florida Energy Code. EF means Energy Factor. 9N HOT WATER CREDIT MULTIPLIERS HWCM SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS Solar Water Heater SF .1 2 3 .4 .5 .6 .7 .8 .9 1.0 HWCM .9 .8 .7 .6 5 .4 .3 .2 .1 .0 Heat Recovery Unit With Air-conditioner eat Pum HWCM .62 Dedicated Heat Pump EF 2.0-2.49 2.5-2.99 3.0-3.49 3.5&U HWCM .44 .35 .29 .25 A HWM must be used in conjunction with all HWCM.See Table 9M.SF means Solar Fraction. EF means Energy Factor. 9P INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST See Section 903.2110 COMPONENTS REQUIREMENTS FOR EACH PRACTICE CHECK PRACTICE#1 COMPLY WITH ALL INFILTRATION PRESCRIPTIVES ON TABLE 9A. PRACTICE#2 COMPLY WITH PRACTICE#1 AND THE FOLLOWING: Exterior Walls and Floors Top plate penetrations sealed.Infiltration barrier installed.Sole platefiloor joint caulked or sealed. Exterior Walls&Ceilings Penetrations,joints and cracks on interior surface caulked,sealed or gasketed. +� Ductwork Ductwork in unconditioned space must be sealed. Fireplaces Equipped with outside combustion air,doors,and flue dampers, Exhaust Fans Equipped with dam ers.Combustion devices see 903.2(f). Combustion Heating Combustions ace&water heating systems provided with outside combustion air,except direct vent appliances. PRACTICE#3 COMPLY WITH PRACTICES#1 AND#2 AND THE FOLLOWING: Ceilings Infiltration barrier installed. Interior Walls Top plate penetrations sealed or hints&cracks on interior walls caulked,sealed or gasketed. Recessed Lights Sealed from conditioned space&insulated from ventilated attics aces. Ductwork All ductwork located in conditioned space. Combustion Appliances Be in unconditioned space(except direct vent),draw air from unconditioned space,exhaust by-products to outside.Stoves see 903.2(f). 6 SUMMER POINT MULTIPLIERS (SPM) 9B SUMMER OVERHANG FACTORS(SOF)For single and double pane glass. CLIMATE ZONES 12 3 10. OH RATIO .0-11 .12-.17 .18-.26 .27-,35 .36- 6 .47-.57 .58-.70 .71-,83 .84-1.18 1.19-1.72 1.73-2.73 2.74+ N 1. 91 .87 .79 .76 .72 .69 .63 .56 50 Y M I NE/NW 1 .94 .9 .86 .80 .75 .71 .67 .63 .55 .48 .42 J o E/W 1.0 92. .86 .80 .73 .68 .63 .57 47 39 .31 N SE/SW 1.0 .93 .90 .74 .66 .54 .47 .39 .32 .27 S 11170 19 ' 1 .86 1 f7_7T .68 1 .60 1 CO .51 .45 .39 .35 .31 OH LENGTH* _Fft. I 1 ft. 1 11/2 ft. I 2 ft. 3 ft. 1 31/2 ft. 1 41/2 ft. 51h ft. 6Y2 ft. 9Y2 ft. 14 it. 20 ft.- *To select by Overhang Length,no part of glass shall be more than 8 ft.below the overhang. OVERHANG RATIO= OH LENGTH OH HEIGHT H L H H 9C WALL SUMMER POINT MULTIPLIERS(SPM) FRAME CONCRETE BLOCK' FACE BRICK WOOD STEEL INT.INSULATION EXT.INSUL R-VALUE WOOD FR LOG R-VALUE EXT ADJ EXT ADJ NORMAL WT. NOR.WT. 0- 6.9 2.4 6 INCH 0- 6.9 5.5 2.2 7.6 2.8 R-VALUE EXT ADJ EXT 7-10.9 .6 R-VALUE ]EW 7.10.9 2.1 .8 3.5 1.3 0- 2.9 2.2 1.1 2.2 11-18.9 .4 0-2.9 11-12.9 1.7 .7 2.7 1.0 3- 4.9 1.3 .8 .8 19-25.9 .2 3.6.9 13.18:9 1.5 .6 2.5 0.9 5- 6.9 1.0 .7 .5 26&Up .1 7&Up 19-25.9 .9 .4 2.2 0.8 7-10.9 .7 .5 .3 R-VALUE BLOCK 8 INCH 26&U 6 .2 1.2 0.4 11 -18.9 .4 .4 .0 0- 2.9 1.0 R-VALUE 19.25.9 .2 .2 .;;; 3- 6.9 .6 0-2.9 26&Up .1 .1 7. 9.9 .4 3-6.9 10&Up 2 7&U 9D DOOR SUMMER POINT MULTIPLIERS(SPM) 9E CEILING SUMMER POINT MULTIPLIERS(SPM) DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF R-VALUE SPM _R-VALUE SPM CEILING TYPE WOOD 6.1 2.4 19-21.9 1.1 10-10.9 2.9 R-VALUE DROPPED EXPOSED- 22-25.9 .9 11 -12.9 2.6 10-13.9 3.2 3.5 INSULATED <f43> 1.6 26-29.9 .8 13-18.9 2.4 14-20.9 2.2 2.4 30-37.9 .6 19-25.9 1.8 21 &U 1.5 1.6 38&U .5 26&LID 1.2h . 9F FLOOR SUMMER POINT MULTIPLIERS(SPM) SLAB-ON-GRADE RAISED RAISED WOOD2 EDGE INSULATION CONCRETE POST OR PIER STEM WALL Wf UNDER R-VALUE SPM FI-VALUE SPM CONSTRUCTION FLOOR INSULATION ADJACENT 0-2.9 -41.2 0-2.9 - .8 A-VAL 0- 6.9 0.0 »` '.=..;.1:< 2.2 -4.9 7. - 3 2 3-4.9 -1.3 7-10.9 -1.4 -2.3 8 5-6.9 -36.2 5.6.9 -1.3 1 -18.9 -1.3 -1.9 ,7 7&U -35.7 7&U -1.3 1 -1.1 -1,5 4 9H DUCT MULTIPLIERS(DM) 9G INFILTRATION SUMMER POINT MULTIPLIERS(SPM) Return Ducts Return Ducts R-Value In Unconditioned Space In Conditioned Space INFILTRATION PRACTICE SPM Supply 4.2-5.9 1.14 1.10 (See Table 9P) Ducts in 6.0-6.6 cl:m 1,07 PRACTICE#1 10.2 Unconditioned Space 6.7&up 1.09 1.06 PRACTICE a 2 8.0 Supply 4.2-5.9 1.10 1.00 PRACTICE a 3 5.2 Ducts in 6.0-6.6 1.07 1.00 Conditioned Space' 6.7&up 1.06 1.00 ' For multipliers for other types of concrete block construction see section 903.2(b). 2 For multipliers for other types of raised wood assemblies see section 903.2(e) 1. 3 Ducts in conditioned space need to be insulated only to the R-Value necessary to prevent condensation. -3- CITY OF ATLANTIC BEACH PERMIT_CALCULATION SHEET + Address C�P Date ] s�"' —► Heated Square Footage 0� @ $ per sq ft = $ Garage/Shed @ $ per sq ft = $ Carport/Porch ` @ $ per sq ft = $ Deck \�\I @ $ per sq ft = $ Patio �S @ $ per sq ft = $ TOTAL VALUATION: $ tD Toth aluation 1st $ Remaining Value per thousand or portion thereof TOTAL BUILDING FEE $�� o so + 1/2 Filing Fee $_ !/ ) Fireplaces @ $15 .00 $ BUILDING PERMIT FEE $ e�92 S. WATER IMPACT FEE $ CIO • ` SEWER IMPACT FEE $ ,5-V.0 C) _ WATER METER/TAP $ �D CAPITAL IMPROVEMENT $ ,��� _ SEWER TAP S_ ( �j ) RADON (HRS) .0050 $ 3• -7 ,/9 SECTION H PAVING ( ) $ HYDRAULIC SHARES $ CROSS CONNECTION $ C� (`�S( ) SURCHARGE .0050 $ 3.3 8 36 OTHER $ -- C) -- GRAND TOTAL DUE $ a:2-85 •Q ADDITIONAL PERMITS OR FEES: Mechanical Plumbing Electric/New Electric/Temp ; SwimmingPool Septic Tank Well Sign Finish Floor Elevation Survey Other CALCULATIONS and/or NOTES: Date Shee>- =- 5 ear t,,Jal,�S Qvt sis Y 1St stOya $ +she t�►e was 1a-�� cs� :, s tit, Y c- t -t t� bO )(o•? O( 12-)( -7 500 l b s �b•2� �� = C3S)C12.) C�.b2s}� 3Zo3 p�F ne, cyntd&4svf p0r t w i k -(e a s �F,nc d Sc w S s c c Com, l F -# - r U-A i s VA 3 q x 14 rA = C o4 6) I ( 3 0o-o� 4--� Fc=zo P F5 8$3)CI•33_ 3l .�• �T_ psi F�v- 00��C1,33)�3o�C8)_rZ•q(JSt L J 3S // �� 1C __- (' y O it 4 Garas•a al•1 cm, sis•� • r N N N 4 �✓ —' }Il k ate Sheet i� /-94 5 eaw- w s Avxaliras i t For Set.vxoj (�� t�,sp ,►.� .� �.1 s vwt this skeet nt w olt- cf;ue,4 wale W e- w Fa r tj,o.0 S an-= L X Z )(l'6 s)�Zg-Zz95 "Lr lbS/FL) = ZV9Sk,67= 43�' oY G = C289S)(S� =�7Z Ibs 161 —� use 7111,oS6 NAILED ON MooQa.Q N�•M S?q g "S�w�s w� �d� 11 c -o2vwtit j a,� b u(_,L Foy- 1e'Lfev,4 l-oej Trev^S Fey, vie- AvKS S%Vwp SV4 StyTteh awlorc (4u00 - 'S11ea✓' = 500 16S ==> �5P 00 �•I S� �► / 39 stereAt vPl�tr in I t M`" + � ' T ,`fit, �.p Z-Q I � •--� �;r ice--. I, r lrx 4 1 �J��� t:uirrto•.' N 1� J . r0 1 I- 44 s Date 3 / �� 9Q l• Ga,6 •E• z L, h AIvw ., W� ,a(uu,,j��Q /w,� .= 41 1b /csq• Cf 5�Pp !70 : 5,G• != 0.55. , z v�J ae f S u.c,t;v—+ / yi c-4 -- )(1.AC 1) =' 55-9 )6j/'na'L P,Lltn,.t .W��-I .Otra-illx A%a4 = 8Z lbs X55.9 lbs o '� s_ 2 tJ p1: v-VI W O-U3 vtorVQ f5o S1Iea/,r- U,)Aip s -Oy- t'o UJ Q A(ec tuvt 1st a0air v�u� - CU•4X Z8 )+ C�•o )t 2g —Za1C 7S0 /2) = 1llom tbj 7-kA Nor Imt �Ct,4)C zq )tCt•o )ct -700 1Z) ' 1st Fl, \-I-100 )(0,65 V c is )Co•S)= y�9 P$F -xa Floor UPOt / Ft .t'I6SZOXO'G5 V (48)(O- ) = 441 fP /4lluw• �pr�Ft Cw lst Flv����( o•3t> CZo,00o�Ct•33) / 5�= 1��9 p��� � °-= C *S (OAI VK 5/ o•t-) I�IEv� v��,Ft cz) Z,4 6SOI (p it, Q� 441 P--FF I� ( CS tso r S�Y �cs+R;' a� 3Z 0-c•S IALUVI upt I rtr ^ zvyl Coo,( W 1ROOP Tfwises St-rafP`t to hear ' %A4115 J nn o•551' 0,;64 Roo F F<4wLv:l .wIL bp- CTA-qem Utile. ° S ee �l•,s t C',n�iv�ee s v PY�aY b Fo r V r Li r t- o,i (ooFtiSSeS �cC,ttcs�, 6 F ? E For Y'-,u+Y-J Sty tuf pLazs �� !✓ i Sheet/ Date _ Z f qi L• G0.6 r1eL� •t ' of .s -,-spee4 - IIQ M f MRH - Zo Ft, gu Leu (o' -Q•���t -� s6cmTa6le I2.05.2A basic = 28' psF © W,d/ kooF4 MwFs RooF P ttL RooF � F(vyM moble- Coerr, Cu�-Patextt-¢-G G P _ _ 1.5 C Co'rhe rs s� 3 C. SUe_ Wkeve �� � =t�•3 �(2� � =3( PSF �yVjm t4ble. IZo5.ZE - SBC-91 : - Roof CoeFF. a4c-,,ti C IoLaZ30 --� GCp = -2.x"1 C Co����s � _� = Cz•7 Cz$� _ �� PsF fivm te.bte 17.o5- Z6 •- MwFs Trams. d%rdjwnn t0 - OL /- 30 �4 UOS J b� _-� Cas e- A GCP (w .:,JW"J vti, ,� s� +o•-t o Cwt Ir+ternaQ p(essIAk) GGp LtgWA4 cM w,.F,(.S Coy , &C-P C waJLjcw ' ux f0dP)= - 1.4 G cep C kyw,4AJ v� rvu j ' _s•o Ca se A LAA 0% wau4)= +I.I (vit NcerAC4 Sv(,tiow) �►,�1 �w+e G-Cp C Lee W"J wt W AU J) _ -0.55 Coe FF. GGA Cwt WWd (PA 'COA _ -1.0 CGcPC leeward U-LN Y-00 z -a•G0 MW F S w. �-o NS�tuct�K��i �iraiU'-A . - l.00 CASE (32 W/ lnter►+aQ Presskre 2-y%40 s eJ b W �� Gt p L W IoJ W AJ LrA w,,-A _ +0.50 3vv%e Gc P CI-e:.wan.Q vv\ kAejfs� _ - 0•'70 Coerf. Gc-P f�&J&,V- Q �n. t�oF�= —i•9� GT (Av�*-J T�, raoF)= -o.so �0r -S�ta,r Ile- �Csb,e •)_ Ct•Co5� C2g = 4�•2 psi OC Ame-,-�sis � aQes��� :- � R��� � wo,Q� �1��f�.r IF Sl�eai is ;tt�d cs� � o•c- =i up��Ftl,nQ.:�? = C �� )Cz�Co•S�- 7� 1}ss 5i�ACc eaCA. viwL e i1 t loe vz-. oas Date 6aL, pe�rc�v� . e u bS n�•.i,� r s ► a �a s :,1 e Po Uvw,.►� g true to cA L A ttri 6tite w r5t Rovr 0.1 a.U. : - fS "CMU RV 4 � TYu SSL S - •— rneer� 1chiSel Firamf^A see f}YcL, PLOOV-r IYM 511 , P � �• ( I(Q,W;r See 5cliecRu& "C" a%i Orck bec.bAr4 4rac,J►v Cse-t-uo-A o'r CMU W off Yom^FoYG�v+ao, :- -t." CMU Ye.;,goYCej VertiC.c,.aLa diItnb St.,ul,,n cs� S i,. u.ie- °, 5`oyc ko r►3.'1•t . C� (o"0•C- Secu gooY W 51�� Kc„� r- gd �� »mss UTA (r'O v� �terwr SL.PPorCs n4rl� 0 6EWwi se UM Sinew W�•�Q tz,�le (ZooF s����{�`' nail Q g� Cuw �+ �if� ,n�:..PS V � � It (J'1� &nQ.C. QVt PAI-14 r� Q aM e0 W1 1 Z Q,C• Ove �+be r, ed,: 5 t.�•p,�pY tS. ��Less hots I" M s �00Y Q'rPA �'Y1C Ata�t .� P 0(C.W-i 4 DOCY644iZ S) :- 75 V t'ti 2 Y\s floor OmA C TnLQ"L;n O ' O 2 �t00 Y QEt i wter" * 112— Z F� ARCHITECT/ENGINEERS CERTIFICATION COASTAL CONSTRUCTION CODE FOR ALL MAJOR STRUCTURE TO BE LOCATED WITHIN CITY OF ATLANTIC BRACH, FLORI A APPLICANT'S NAMES PHONE NO. DATE OWNER NAME: R.E. TAX NO. : TYPE OF PROJECTS New Home )Residential Addition • Garage ( )Pool ( )New Commercial ( )Commercial Addition ( )other 911 STREET ADREBS: ( ) Wo 'claim the structure to be exempt as follows: ( ) oarage with no provision for occupancy - detached one and two family only ( ) Pier, Dock, etc. ( ) Other (.Specify) I also certify that no structure listed above may be remodeled or converted to a non-exempt use without being upgraded to fully comply with the ordinance. Signed: Date: ---------------------------------------------------------------- CERTIFICATION This certifies that the plans. and specifications subfitted and sealed by the undersigned meet all criteria set forth b the City of Atlantic Beach Coastal Construction Code. Roof covering is exempt from the 110 mph requirements of the Coastal Construction Code, but meet all the other requirements of the City of Atlantic Beach Building Code. (y/') The structure including foundation, frame, roof decking, exterior walls and floors has been designed for wind loads of 110 mph, with all design complying with. the 19% , Chapter 12 , Standard Building Code. ---------------------------------- -------------------------- e cf w4Ua.�c r o r r i rte^^ ✓��•- o f otoon (nl�i►w�WW S ( ) Windows, doors and all other esterior devices comply with the 110 mph wind load. ( The structure is located outside the area affected by wave forces, OR ( ) The structure is capable of withstanding wave forcea resulting from a wave crest height of feet above MSL including uplift forces. ------------------------1------------------------M--------- ( -- --------- ------------ ( The structure is located in FIA Zone—A and the foundation design has considered possible exposure to water and erosion . OR ( ) The structure is located in FIA Zone X and the foundation will not be exposed to hydrodynamic, hydrostatic loads or water scour, OR r ( ) Foundation design has brier_ . co:npi+tea !jig:: M Ya; e:_-Yat-ion above the specified stillwater, elevation, and to resist wave, hydrodynamic, hydrostatic and wind loads acting simttl.taneously with dead loads. Erosion computgtiond for - the foundation A_Otr'jn have 16.2her. into iCCC.MriW.. kko je ctigu 3U-yeai eros' on losses from. a 100 year storm event and all vertica= and LOUIS J. GABRIEL 9610 BROKEN OAR BLVD. JACKSONVILLE FLORIDA 32257 94 Re:- Wind Loading Recluirements For The New Residence Located On I B? 9 �, Ay Alla-ACe e)eac -t , FL. To Whom It May Concern:- I have reviewed the architectural drawings of the subject residence and conducted a wind loading structural analysis, that covered uplift analysis, shear walls analysis, anchorage to footings, hold-downs strapping analysis, and concluded that the residence structure will satisfy wind load requirements of section 1205 of the 1991-SBC for wind speeds of 110- mph as long as sheets #1 thru #7- of the architectural drawings are satisfied. It shall be noted that I have no knowledge of any subsurface soil condition report; thus, all footings are designed as shallow footings bearing on soil that possess a maximum allowable bearing pressure of 2000 psf. If contractor found any differing conditions either through soil report or soil removal, then I shall be notified and possible footings design revisions may have to be implemented prior to commencing work. I have attached a copy of the analysis for the record.Please let me know, If I can be of any further help. SiLoer.ely . Louis J' . Gabriel "WIND FORCES STRUCTURAL ANALYSIS FOR THE NEW RESIDENCE LOCATED ON (E7 9 �lC Cc to A\[EN U E ATLRN'TI L 9,egc14 , FL. THE ANALYSIS IS STRICTLY DONE TO INSURE COMPLIANCE WITH THE MINIMUM WIND LOADING REQUIREMENTS FOR 110 MPH WIND SPEEDS AS OUTLINED BY SECTION 1205 OF THE 1991-STANDARD BUILDING CODE" PREPARED BY:-LOUIS GABRIEL, P.E. DATE:-NOVEM6r;fL, 1994 7994 ii J�� CITY OF ATLANTIC BEACH Fixture Unit Worksheet for Water Impact Fee FIXTURE UNITS ARE ESTABLISHED AS THE MEASUREMENT OF WATER DEMAND FOR EACH WATER FIXTURE UNIT INSTALLED AND CONNECTED TO THE CITY WATER SYSTEM. THE WATER SUPPLY CHARGE IS HEREBY FIXED AT TWENTY DOLLARS PER FIXTURE UNIT CONNECTED TO THE CITY WATER SYSTEM. BATHROOM GROUP CONSISTING OF SERVICE SINK TRAP STAND WATER CLOSET, LAVATORY & BATH (8) TUB OR SHOWER STALL (6) C, (b WATER CLOSET WATER CLOSET, TANK OPERATED (4) VALVE OPERATED (8) BATHTUB/SHOWER (2) URINAL WALL LIP (4) SHOWER GROUP PER HEAD (3) FLOOR DRAIN (1) SHOWER STALL DOMESTIC (2) LAUNDRY TRAY (2) LAVATORY (1) COMBINATION SINK AND TRAY (3) WASHING MACHINE (3) POT, SCULLERY SINK (4) DISHWASHER (2) WASH SINK EACH SET OF FAUCETS (2) KITCHEN SINK (2) DENTAL LAVATORY (1) KITCHEN SINK WITH WASTE 3 DENTAL UNIT OR CUSPIDOR (1) GRINDER (3) BIDET (3) URINAL STALL, WASHOUT (4) FLUSHING RIM SINK (8) COMBINATION SINK AND TRAY WITH FOOD DISPOS. (4) URINAL, PEDESTAL, SYPHON JET DRINKING FOUNTAIN (1/2) BLOWOUT (2) LAVATORY, BARBER/BEAUTY ICE MAKER (1/2) . S SHOP (2) SURGEONS SINK (3)JACUZZI (2) URINAL 0 LAVATORY, SURGEONS (2) _ STALL, WASHOUT (4) TOTAL FIXTURE UNITS_ Y @ $20.00 EACH $ 9(91 00 JOB INFORMATION (%OICaC �f= rte i %;ktrttf tratr of Wrrupattrij CITY OF oftft& &4A- Rami 1 Erpttrimatf of Vititdittg Atsprrfiott This Certificate issued pursuant to the requirements of Section 109 of the Southern Standard Building Code certifying that at the time of issuance this structure was ill compliance with the various ordinances regulating building construction or use. For the fol' use Classification. Si?2 '.f'. :r•:e:,..ly Kt'. 1 4" r E: Bldg.Per Group g Y .i nie Type Construction __Fire District_A t l ail t i � f Owner of Building_G"4'a l is it< L a rJ'',1 Address 1± R- 4 Building Address. 1989 B(=C• i_ve'lt�P _Locality Ats.a'ILie � ttvv By _c^_ ( Building Official Date: I TOOT IN A CONS►ICUOUa PLACIE sy i PA10 (VJ CITY OF I�! ,ate Bim-0;&ota- Office of Building Official RQ REQUEST FOR INSPECTION A9 Date 1- 1---93 Permit No. Time !!P O ' tl �w _ _ Received �T ,M. District No. 9 *es -JP- Addr Locality Re � Owner's A�fjng Name Contracto BUIing G CONCRETE ELECTRICAL to UMBING l ECHANiCifl� MSA ra ❑ Footing ❑ Rough Wiring ❑ ug ❑ 1Str 6end.8�_ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating iosp�r Lintel ❑ Fire Place ❑ is ,OOM FOR INSPECTION Pro Fab ace A.M. jOr \ Mon. Tues. Wed. Thurs. Friday P.M. \ A.M. Inspection Made .— P.M. Inspector � Mallnspectio Certificate of Occupancy —� Date �J day a6 O�rfi/jute° �pq.M afa r� •M. o� CITY OF Office of Building Official '5S REQUEST FOR INSPECTION, �- Date Permit No. `y T 6 Time District No. Received P.M. 09/ Job Addre „ Locality Owner's Nam BUILDI G CONCRETE LECTRICAL �BING fECHANICAFooting ❑ Roug Ping Air. Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out Heating Lintel ❑ Fire Place ❑ Pre Fab READY FOR INSPECTION A.M. Mon. Tues. Wei Th� FTvt—� Friday P.M. 6 f �. A.M. Inspection Madgr Inspector Final inspection❑ 1 y Certificate of Occupancy Date CITY OF 4&44tic Se4d- Office of Building Official REQUEST FOR INSPECTION Date 3 Permit No. Time A.M. Received P.M. District No. Job Address Locality Owner's Name Contractor BUILDINGCONCRETE ELECTRICAL PLUMBING MECHANICAL Framing _3 Rough Wiring ❑ Rough ❑ Air.Cond.& ❑ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Lintel Final ❑ Sewer ❑ Fire Place ❑ READY FOR INSPECTION Pre Fab � A.M. Mon. Tues f3d. Thurs. Friday P.M. Inspection Made Inspector - Final Inspection❑ Certificate of Occupancy Date CITY OF 4Aut4-c Beads-0;kucla 6,1Z Office of Building Official REQUEST FOR INSPECTION Date —� ~ _ Permit No. Time Received P.M. y District No. Job Ad �, e � �.•--6 Locality Owner Name Contra BUILDING CONCRETE�-- ELECTRICAL r PLUMBING MECHANICAL Framing ❑ Rough Wiring ❑ Rough ❑ Air.Cond.& ❑ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Lintel ❑ Fire Place ❑ Pre Fab READY FOR INS/ A.M. Mon. Tues. Wed. Thur.. Friday P.M. Inspection Made r p M Inspector Final Inspection❑ Certificate of Occupancy Date CITY OF Office of Building Official REQUEST FOR INSPECTION )G/CT/ DateM Permit No. –'=�—i" TimeDistrict No. Received 'C� M. ,� -:t–x--�� Job AdJ ocality Owner's Name ontra Z�,, BUILDING CONCRETE PLUMBI G MECHANICAL Framing ❑ Footing ❑ Rough Wiring ❑ Rough El Air.Cond.& ❑ Re Roofing El Slab 11 Temp Pole '--Top Out ❑ Heating Lintel ❑ Fire Place ❑ Pre Fab FOR INSPECTION A.M. Mon. Tues. Wed. Thurs. Friday—P.M. A.M. Inspection Maae F•M• Inspector—F. t •' LFinal Inspection 7� Certificate of Occupancy Date CITY OF 4&4A,4.0 Be40A-#;&U*4& Office of Building Official REQUEST FOR INSPECTION Date Permit No. TimeA•tv�� Received C, M. District No. Jodress Locality Namer s ✓2 Contractor BUILDING---/ CRETE ELECTRICAL PLUMBING MECHANICAL Framing ❑ Footing Rough Wiring ❑ Rough ❑ Air.Cond.& ❑ Re Roofing ❑ Slab Temp Pole ❑' Top Out ❑ Heating Lintel ❑ Fire Place ❑ Pre Fab -- READY FOR INSPECTION A M Mon. Tues. V(/N Thurs. \ Friday P.M. Inspection Made P•M• ` Inspector r Final inspection❑ Certificate of Occupancy Date CITY OF Office of Building Official REQUEST FOR INSPECTION Date Permit No. Time / A.M. Received P,M. District No. Job Ad resslity Owner, Nams� t / ILLi/jj/000//�yaaa Name ✓c«G�- GC-� Contractor—�� 7 / BUILDING CONCRETE ELECTRICALUMBF MECHANICAL Framing ❑ Footing ❑ Rough Wiring ❑ Air.Cond.& ❑ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Lintel ❑ Fire Place ❑ Pre Fab READY FOR INSPECTIONas A.M. Mon. Tues. Wed. Thurs. F� riday ) P.M. Inspection Made Inspector "t Final Inspection❑ Certificate of Occupancy Date CITY OF 4&4a4c Bea A-QaUk& Office of Building Official Lxx REQUEST FOR INSPECTION Date Permit No. Time A.M. Received P.M. District No. /071 A3 Ak-c Job Address Locality Name Contractor i osE"�' S BUILDING CONCR ELECTRICAL PLUMBING MECHANICAL Framing ❑ Footing ❑ Rough Wiring ❑ Rough ❑ Air.Cond.& ❑ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Fire Place ❑ Lintel �( Pre Fab READY FOR INSPECTION A Mon. Tues. Wed. Thurs. ,�ay j A.M. Inspection Inspection Made r L` �" P.M. Inspector < Final Inspection❑ Certificate of Occupancy Date CITY OF- Off ice FOffice of Building Official REQUEST FOR INSPECTION - 4--Date � Permit No. �0 Time A.M. Received _P.M. District No. 4 Job ress / Locality Owner's Name r BUILDING CONCRETE elCAL PLUMBING MECHANICAL Framing ❑ Footing ❑ ❑ Rough ❑ Air.Cond.& ❑ Re Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Lintel ❑ Fire Place ❑ Pre Fab RE FOR INSPECTION A.M. Mon. Tues. Wed. Thu rs. Friday-P.M. Inspection Maadddee..��9 Z- / P.M. Inspector E °"T tj C-(�,(FA Final lnspectionx Certificate of Occupancy Date -, q 2 CITY OF 4&aa& Be=4-&7AWJ4 Office of Building Official REQUEST FOR INSPECTION Date �..,� ` � Permit No. Time lj A.M. P M District No. Received / 8 / �� / 9 Jo dr s G —� Locality a Owner's �� ��t�� '' Nam Contractor b IL ING CONCRETE ELECTRICAL PLUMBING MECHANICAL min ❑ Footing ❑ Rough Wiring ❑ Rough ❑ Air.Cond.& ❑ Be Roofing ❑ Slab ❑ Temp Pole ❑ Top Out ❑ Heating Lintel ❑ Fire Place ❑ Pre Fab READY FOR INSPEEA.M. Mon. Tues. L Wed.`/� urs. Friday P.M. Inspection Made T 7 Inspector Final Inspection❑ Certificate of Occupancy �� Date CITY OF ,rt'at`ce vecd - f'ozcda {� 800.SF:NFINOLE ROAD A17.A`I U' t3F,WIL FLOR10%322 3-5345 1ELL111 NE 19011 247-zWO FAX 19041 247-5905 NOTlCE To: Water Department City of Atlantic Beach Date: = �- Please be advised that the final building inspection has been completed on each of the following addresses and construction water is no longer required: Permit Number Address J -------------- ------------------------------------------- -------------- ------------------------------------------- -------------- ---__--_--_-------_-_---_---____----_--_w_ -------------- -------------------------------------------- Sincerely, Don C. Ford Building Official DCF/pah cc: City Manager CITY OF :IROPERTV DESCRIPTION r� 716 OCEAN BOULEVARD .ot 1►__ -__Black 0-------- ection #-----_ wt P.O.BOX 25 F E.B - 71992 TLANnC BEACH,FLORIDA 32233 TELEPHONE 11;041249.2J95 aubdiviaions_� t-�r�+ f •7-� '�iC_ �r:�c':1Gd��,-------- �,vai.�P� �`s�� c�' nd Z c n `orf street Name DESCRIPTION OF WORK it Addresas '7`r_w�r,Qt't __ � w w_,..-ww-wrww..w- It in a FLOOD HAZARD •lcod Zones _-__ area complete page 3. Brief Descriptions_ uc=K Class o1 Works tNev/Resodwl/Addition)- �je'a :OHING INFORMATION Type o1 • Constructions-• C� _j r?ri�M :oning -, Proposed , istricts z--Use:____ _- Estimated Vilue •JA 4,?vqc______ :xceptions or � :" Matwrialss__„_„______„ ariances Grantwds -_-_---- Solid or ----------_..r----------r-------- ------ Filled Grounds_==�_r:......Roof s OWNER INFORMATION Method o1 Meetings �f� y�, fl-SV7- g3S-34.-k- Property Ovners_Mi.�Y,�a-iilri..�------------ ------------- Phones ( Nailing ------- Address-== --�- _{5 --------------------------------- .._ C—_—r---- `9 Zips t`s --------------r-----_-- ------------,---- ' r 1� CONTRACTOR INFORMATION Contractors_ 1drs_ Z;'�e p -----_-_---w__ honest Mailing � C, �� - ------- - --- <Addrawas---�------ -- -------------------------=----- ----------------------- zip t Expiration vicense Numbers CT, I2 L _���-��--(---------------------__- Date: I N!RCBV CERTIFY THAT I NATE READ AND CXARINEO THIS APPLICATION AND NNON TN! SAME TO BE TRUE AND CORRECT. ALL PROVISION! OR TUB LAMS AND ORDINANCES OOVERNINO THIS TYPE OF WORK WILL at k COMPLIED WITH, WNiTNN Si EPRC%rIED NRRBIN OR NOT. THE ORANTINO Or A ►!SNIT DOES NOT PRE:;uME t0 DIV! AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS 00 ANY FEDERAL. STAT! OR LOCAL RULM „ REGULATIONS. ORDINANCES. OR LAMS IN ANT MANNER, INCLUOINO THE GOVERNINO OF CONSTRUCTION OR T PERFORMANCE OR CONSTRUCTION OF TNR PROJECT. I UNDlRSTANO THAT TH! t95UANC! OI THIS PERMIT IS V 1 y' LCONTINOENT U►ON THE ABOVE INFORMATION MIND TRUE AND CORRCCT AND THAT TN! PLANS AND SUPPORTING DATA HAVE SCCU OR SNALL• SE PROVIDED AS REQUIRED. A. trt�rl "y Ovner Signature --------------------------------Date------------ r'� ,•a j,r� M , Contractor Signature_y ��� 1:.� �y�-------Dste------------ 4954 DS+ARTMENT:OF BUILDING CITY OF ATLANTIC BEACH a PERMIT INFORMATION -- LOCATION INFORMATION __ `P�ar>w t Numb x^z 4 84 Address; 1879 REACH AVENUE Peart it Types BUILDINGATLANTIC BEACH, FLORIDA 32233 t14, id0, of Warks NEW ----------I LEGAL DESCRIPTION ---------- . Types WOOD FRAME Lott 43, Block: Section. Proposed Us*; SINGLE FAMILY Township: RNG: 0 'I �►+ 11inRl s 1LI , Code: 0 Subdivisions NORTH ATLANTIC BEACH • Elstim*ted Ve l ue s $1942. 0® t Iaprc�v. • Cost s $0. 00 Totei F` $3398.66 s A*oun $3398.66 7` PRO n P2 TION �- - - - �.n.��.... APPLICATION FEES _'_ i+,. firer. x". F'ETRCINI PERMIT $1145. 50 50 VENUE VAT IMPACT 01FEE ow 770.00 tFIX �0 #'44,4,-Aff . 6f y��y t • RADON GAS-H. R.S. $13.42 QRMATI - RADON GAS 5% $0. 71 tlpi6!4 �i# RAMER HUS II`IC. tATI;Rr., ._._w. ,... 0.00 A`f i�E.` �` w aa W SEWER TAP` � $343. 03 ARXCE FL 32009 HYDRAULIC SNARE 00.00 Li e I r T ' 0 RE-INSPECT FEE :` [? ! 'SEC. H IMPACT FEE I' so � "� q wy}� a NOT£S: r I� NOTICE-ALLCONCRETE FORMA A 'CIS MUST BE INSPECTED BEFORE POURING 4 PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE ' BUILDING MATERIAL,RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER OFAJLURE TO COrI1IIPLY WITH THE MECHANICS' LIEN LAW CAN RESULT IN HE Rope ji"WNER PAYING TWICE FOR SUIL©ING IMPROVEMENTS." k N f IS.4UED.ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUWPT TO RE �CTtCFI AOR ° C? 4T1ON'CIF AF 'LIOAS'LEt?fiOfflStC�Ns OF LAW. Its..lt#.�I) > �, , •� � . yYet 01119-, ,��a��a1�cyi , ATLANTICBEACH 13UILDINO DEPARTMENT By: V wx 5S-85-- CITY OF ATLANTIC BEACH, FLORIDA Approved by APPLICATION FOR ELECTRICAL, PERMIT TO THE CHIEF ELECTRICAL INSPECTOR: DATE: 1 IMPORTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, AND IN'ACCORDANCE WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. a -LL.., ELECTRICAL FIRM: MASTER ELECTRIC AN I A NAME. CU R-C f` ADDRESS: 1 g�� i �'�� C � RFD_BOX BLDG.SIZE BETWEEN: RES. rf APT.( ) COMM.( 1 PUBLIC( 1 INDUS.l 1 NEW OLD( 1 REW.( 1 ADDITION( 1 TRAILER ( 1 TEMP.( 1 SIGNS 1 1 SQ. FT. SERVICE: NEWI/ INCREASE( 1 REPAIR ( 1 FEE _ CONDUCTOR SIZE L�/� AMPS �d COPPER ALUM. G SWITCH OR BREAKER AMPS PH W l OLT RACEWAY EXIST.SERV.SIZE AMPS PH W VOLT RACEWAY FEEDERS NO. SIZE IND. SIZE I NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.30 AMPS. 31.100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0.100 AMPS. OVER APPLIANCES J 1 9 1 BELL TRANSF. AIR H.P.RATING H.P.,RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 0.1 OVER MOTORS H.P. VOLTAGE PHS NO. 1 H.P. VOLTAGE PHS MISCELLANEOUS JACKSONVILLE ELECTRIC' AUTH(jklT� WEST DUVAL STREF:T JACKSONVILLE, FLORIDA THE FOLLOWING FINAL HAVI-: SATISFACTOkY : SINCERELY, BUILDING INSPECTION D1Via10N cc : FILE SEWER TAP L.O. FOURAKER BUILDERS P.O.BOX 7 BRYCEVILLE, FL. 32009 1879 BEACH AVENUE JOB COST RECORD I a ('.DESCRIPTION TY.'? 3 ;Q , .'MATERIALS �'.`LABORl TOTALf >` 6" X 6" X 6" GASKET TYPE WYE SDR 35 PVC 1 $9100 6" SDR 35 PVC PIPE 13' $16.25 SUB TOTAL $25.25 10% O.H. $'.2.52 TOTAL $27.77 2 MEN ($27.45/HR) FOR 5 1/ HRS. $150 97 30% O.H. $45 29 TOTAL $196 26 MATERIALS LABOR TOTAL TOTAL $271.771 $1961.26 $224[031 "} ' Sc.J' 8'EXPENSES410 AMOUNT OTI IER 109 EXPENSES $125.00 1 TRUCK 10.00 HR F R /2 HRS. TOTAL COST $349.03 55 0 TOTAL SELLING PRICE 1 BACKHOE 35.00 HR FO HRS. LESS TOTAL COST 70 0 GROSS PROFIT LESS OVERHEAD COST 'L OF SELLING PRICE TOTAL 125 O NET PROFIT r� kf1 5 - I q2 I 210 Pelee QUommm APPLICATION FOR WATER AND/OR SEWER TAP APPLICANT NAME_O ------------- MAILING ___________MAILING ADDRESS ' � -_ PHONE NUMBED{ #J ��-L DATE, _ ------- SERVICE REQUESTED -------- ----------------------------------------------- SERVICE ----------------------------------------------SERVICE LOCATION_LS1 _ 1- 2. � .-------------------- DATE SENT TO �� DATE RETURNED PUBLIC WORKS � _____ TO BUILD. DPT. DATE OWNER NOTIFIED--------------------- i i Y F B ® ' 1992 Pizice QU07s APPLICATION FOR WATER AND/OR SEWER TAP b APPLICANT NAME_ �_L �_s�.1�����L�.c �_�i s ��CF( �I ------- MAILING ADDRESS_ _ f --------------------------------- DATE -� .c PHONE NUMBEF L'ti£{�_��_------ =�------ ----� -y-------------- SERVICE REQUESTED ___ _= ��Q Z e--------- ----------------------------------------------- SERVICE LOCATION_LS.:� ------------------------------------- - DID �7 DATE SENT TODATE RETURNED PUBLIC WORKS_-1-2�._'-1 ___-_ TO BUILD. DPT. DATE OWNER NOTIFIED--------------------- .l 1992 � - �,i �iiji aiicl to i it