Loading...
Permit 1011 Big Pine Key CITY OF I 716 OCEAN BOULEVARD P.0.BOX 25 ATLANTIC BEACH,FLORIDA 32233 r TELEPHONE(904)249-2395 .... ....... March 2, 1987 Third Floor Pre-Service Section Jacksonville Electric Authority Building 233 West Duval Street Jacksonville, Florida 32202 The following final inspections have been made and are satisfactory: Permit *4959 - 1011 Big Pine Key Permit *5148 - 432 Osprey Key Permit #5149 - 436 Osprey �Key Permits issued to Adkins Electric Co. S rely, ene' ngers Community Development Director cc:building file Ll CITY OF ATLANTIC BEACH APPLICATION FOR BUILDING PERMIT Owner Address _zip -7�,-�-3 _Phone 2- Phone �.tect Address /i ZIP )--j--j Contractor Address CT zip Phone Contractor's acense Number z/j-9 Expiration Date on-File. Lot it Z3 e?�Block or Section # Subdivision Zoning Street Between and side Valuation $ Type of Construction Purpose of of Units Fireplaces Utility Service: Water Sewer If the City if providing water or sewer service, do we need to make-taps?. Dimensions: Size Footings Sz. Piers Sz.,-*Sills Greatest Span Sills Sz. Ceiling Joists Distance on Centers. Greatest Span Sz. Floor Joists Distance on Centers Greatest spa� — Sz. Rafters Distance on Centers Greatest Span Method of Heating Solid-Filled Ground Roof Flood Zone If located within a FLDOD HAZARD complete page 2 SUBMIT; Two complete sets of plans, including a detailed site plan. Florida Energy Efficiency Code Sheets Recent Survey Inspections Required-, 1. When steel is in place and ready to pour footings. 2. When steel is in place and ready to pour columns/lintel. 3. When steel is in place and ready to pour bearn. 4. When framing, mechanical, plunbing, electrical, fireplace, is completed and ready to cover up. 5. Final inspection. NO INSPECTION WILL BE MADE IF BUILDING CARD IS NOT POSTED ON JOB. 3 In case of rejection, reinspection HJST be called for after Rear L:)t Line corrections are made. oo-� In consideration of permit given for doing the Cn work as described in the above statement, we FJ- FJ- hereby agree to perform said work in accordance with the attached plans and specifications, which are a part hereof, and in accordance rt rt with the building regulations of Atlantic Beach. V M M Signature Owner Signature Con��actor 14 ront LA)t =e AdOxess Heated Square Footage @ $ ___per sq ft = $ Garage/Shed @ $ ___per sq ft = $ Carport/Porch @ $ _____per sq ft = $ Deck @ $ ____per sq ft = $ Patio @ $ ____per sq ft = $ TOTAL VALUATION: $ 10105 �. 50 Total Valuation Ist $ Remainder Valuation per thousand or portion thereof --------------------------------------------I Total Building Fee $ ADDITIONAL PERMITS and/or FEES REQUIRED I + k Filing Fee $ Fireplaces @ 15.00 $ Mechanical BUILDING,!PEPMT FEE $ Plunbing Electric/New ------------------------------------------------- Electric/Temp 9-79-50 Septic Tank BUILDING PERMIT $ 0=7 Well WATER METER CHARM $ CO &Timming Pool SEWER IMPACT FEE $ ()(D Sign WATER D,1PACT FEE $ 0 � OC) Water Connection MISCELLANEOUS $ Sewer Connection $ Water Meter $ Elevation Certificate GRAND TOTAL DUE $ 5D ---------------------------------------------------------------------------------------------- CALCULATIONS and/or NOTES PLUMBiNG PERMIT ELECTRIC PERMIT BUILDING PERMIT WORKSHEET TERPORARY ELECT. ,-ated Square Footage 0 ,�-o - -9 __per sq ft - irage/Shed 407 @ s 00 er sq ft - p .................. irport @ $ ____per sq ft - )rcbes per sq ft - $ !ck ___per sq ft - $ Itio @ $ _____per sq ft - TOTAL VALUATION 00 -;i 7luation Data �t Va lst z !Z lj-:5- 0 0 36, OC2 mainder Valuation @ $ c;L 60 per tbousand or portion tbereof TOTAL BUILDING FEE + -1 FILING FEE FIREPLACE @15 .00 s TOTAL BUILDING PERMIT -----------------------------7------------------------------- ----------------- UMBING PERMIT FEE$ MECHANICAL PERMIT FEE$ E-CT. TEI-EPORARY $ ELECTRICAL PERMIT $ rER METER SIZE ACCOUNT NUMBER JER IMPACT FEE $ rER CONNECTION $ (@10. 00 p_er fixture unit) 'ROVED BY: TOTAL BUILDING/PLAN FILING FEE $ TOTAL WATER METER CHARGE $ TOTAL SEWER IMPACT FEES s 0 0 TOTAL WATER CONNECTION CHARGE $ 'e767. 00 cMISCELLANEOUS CHARGES $ GRAND TOTAL DUE: s (5- PLUMBING W W SHEET SINKS SHOWERS DISHWASHERS CLOSETS BATH TUBS FLOOR DRAINS WASHING MACHINE WATER HEATERS DISPOSALS LAVATORY URINALS OTHER TOTAL FIXTURE COUNT eJ Sol f5l) FIXTURE 'UNIT'BREAKDOWN FIXTURE UNITS ARE ESTABLISHED AS THE MEASUREMENT OF WATER DEMAND FOR EACH WATER FIXTURE UNIT INSTALLED AND CONNECTED TO THE CITY WATER SYSTEM. THE WATER SUPPLY CHARGE IS HEREBY FIXED AT $10.00 PER FIXTURE UNIT CONNECTED TO THE CITY WATER SYSTEM. BATHROOM GROUP CONSISTING OF LAVATORY (1 UNIT) WATER CLOSET, LAVATORY, AND BATH TUB OR SHOWER STALL SERVICE SINK TRAP STAND (6 UNITS) (3 UNITS) DRINKING FOUNTAIN (ij UNITI URINAL, WALL LIP (4 UNITS) FLOOR DRAIN (I UNIT) - WASHING MACHINE RES. URINALP PEDESTAL, SYPHON (3 UNITS) JET BLOWOUT (-8 UNITS) WATER CLOSETS, VALVE OPERATED WATER CLOSETS, TANK-OPERATED (8 UNITS) OUNITS) SHOWER STALL, DOMESTIC BATHTUB (W./OR W/O OVERHEAD (2 UNITS) SHOWER) (2UNITS) LAUNDRY TRAY BIDGET (.3 UNITS) (2 UNITS) DISHWASHER C2 UNITS) KITCHEN SINK (2 UNITS) 13 KITCHEN SINK/WASTE GRINDER (3 UNITS) 70, Oo TOTAL FIXTURE UNITS @ $10."00 EACH, #7 LO Ao, PLUI-WINU I'LkI-111' # ELECTRIC PERMIT BUILDING PERMIT WORKSHEET TEMPORARY ELECT. 2ated Square Footage /0 $ er sq f t - irage/Shed $ /(foo --Per sq ft - irport $ ___per sq ft - )rches ---per sq ft - !ck $ ___per sq ft - Itio $ ---Per sq ft - TOTAL VALUATION '7Y/ ,tal Valuation Data lst F� c3f-4 0 / . $ S-6 mainder Valuation @ $ ;� .37)per tbousand or portion tbereof TOTAL BUILDING FEE s + -1 FILING FEE s FIREPLACE @15 .00 $ 60 TOTAL BUILDING PERI-11T $ -----------------------------7-------------------------------------------------- JMBING PERMIT FEE$ MF-CHANICAL PERMIT FEE$ --CT. TE1-1PORARY $ ELECTRICAL PERMIT $ PER METER SIZE $ ACCOUNT NUMBER 4ER IM�PACT FEE $ �ER CONNECTION $ (@10. 00 p�er fixture unit) 'ROVED BY: TOTAL BUILDING/PLAN FILING FEE TOTAL WATER METER CHARGE $ TOTAL SEWER IMPACT FEES 103,S- 60 TOTAL WATER CONNECTION CHARGE 00 - 00 MISCELLANEOUS CHARGES GRAND TOTAL DUE: s vs� PLUMBING WOQRKSHEET SINKS SHOWERS DISHWASHERS ' CLOSETS BATH TUBS FLOOR DRAINS " ' . WASHING MACHINE WATER HEATERS DISPOSALS 3- LAVATORY URINALS OTHER TOTAL FIXTURE COUNT' FIXTURE UNIT 'BREAKDOWN FIXTURE UNITS ARE ESTABLISHED AS THE MEASUREMENT OF WATER DEMAND FOR EACH WATER FIXTURE UNIT INSTALLED AND CONNECTED TO THE CITY WATER SYSTEM. THE WATER SUPPLY CHARGE IS HEREBY FIXED AT $10.00 PER FIXTURE UNIT CONNECTED TO THE CITY WATER SYSTEM. BATHROOM GROUP CONSISTING OF LAVATORY (1 UNIT) WATER CLOSET, LAVATORY, AND BATH TUB OR SHOWER STALL SERVICE SINK TRAP STAND (6 UNITS) (3 UNITS) DRINKING FOUNTAIN (!I UNITI URINAL WALL LIP FLOOR DRAIN (I UNIT) * (4. UNITS) URINAL PEDESTAL, SYPHON WASHING MACHINE RES. v (3 .UNITS) JET BLOWOUT (B UNITS) 1V WATER CLOSETS, TANK-OPERATED WATER CLOSETS, VALVE OPERATED (8 UNITS) OUNITS) SHOWER STALL, DOMESTIC BATHTUB (W./OR W/O OVERHEAD (2 UNITS) SHOWER) UUNITS) LAUNDRY TRAY BIDGET (3 UNITS) (2 UNITS) DISHWASHER (2 UNITS) KITCHEN SINK (2 UNITS) KITCHEN SINK/WASTE GRINDER (3 UNITS) 9,06-00 TOTAL FIXTURE UNITS @ ,$10.,00- EACff, CITY OF 1*rew� Ewa - 716 OCEAN BOULEVARD P.0.BOX 25 ATLANTIC BEACH,FLORIDA 32233 TELEPHONE(904)249-2395 The Minimum Lowest Floor Elevation for Lot jZ j- 3q O<Oju-o is A Survey indicating the "Lowest Floor Elevation" shall be submitted to the Building Department "Immediately" after the slab has been poured. No further inspections will be made until the survey is on file. No Final Inspection will be made and No Certificate of Occupancy will be issued unless the Minimum Elevation Requirement is met. Building (&partmAt Representative CITY OF ATLANTIC BEACH, FLORIDA ^ppro-d by APPLICATION FOR ELECTRICAL PERMIT .4c TO THE CHIEF ELECTRICAL INSPECTOR: DATE: RTANT NOTICE: IN CONSIDERATION OF PERMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, WE HEREBY AGREE TO PERFORM SA16 WORK IN ACCORDANCE WITH THE ATTACHED PLANS AND SPECIFICATIONS, WHICH ARE A PART HEREOF, ANDI:IN WITH THE ELECTRICAL REGULATIONS, CODES AND CITY OF ATLANTIC BEACH ORDINANCES. 'ELECTRICAL FIRM: NkASTER ELrzCTRICI&N SIGN&WRE JOURNZYMAN NAME-II (CM �tj)qiA*41 ADDRESS:_10LI NL RFD-BOX BLDG.SIZE BETWEEN: RE&KAPT.( COMM.I PUBLIC( I INDUS. ( NEW OLD�l REW.I I 11 ADDITION I TRAILER I TEMP.I SIGNS -SO.FT. SERVICE: NEW INCREASE I I REPAIR ( I FEE CONDUCTOR SIZE /D AMPS I S-0 COPPER ( ALUM.I SWITCH OR BREAKER L2& Mo PH 3 W VOLT R ELNAY EXIST.SERV.SIZE AMPS PH W VOLTI RACEWAY FEEDERS NO.'' SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.30 AMPS, 31-100 AMPS. SWITCHES INCANDESCENT FLUORESCENT&M.V. FIXED 0-100 Ampm� I OVER APPLIANCES BELL TRANSF. AIR H.P.RATING H.P. RATING CONDITIONING COMP.MOTOR OTHER MOTORS AMPS CEIL HEAT: KW-HEAT 4", rO L L Af UNDIER 600 V. OVER 600 V. TRArJ_qFnRUFR.Q! I lill I CITY OF ATLANTIC BEACH APPLICATION FOR PLEIRMING PER14XT /0// )6 , JOB LOCATION: OWNER OF PROPERTY: TELEPHONE NO?'-V1l--l-?;Y d/7 c— PLUMBING CONTRACTOR CONTRACTOR' S ADDRESS : STATE LICENSE NUMBER: TELEPHONE: HOW MANY OF THE FOLLOWING FIXTURES INSTALLED SINKS SHOWERS LAVATORY WATER HEATERS BATH TUBS DISHWASHERS URINALS DISPOSALS CLOSETS WASHING MACHINE FLOOR DRAINS SHOWER PANS SEWER WATER REPIPE OTHER TOTAL FIXTURES : x $3 . 50 + $15 . 00 MINIMUM PERMIT FEE — $25 . 00 SIGNATURE OF OWNER: SIGNATURE OF CONTRACTOR: ----------------------------------------------------------------- INSTALLATION OF PLUMBING AND FIXTURES MUST BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE. CALL A DAY AHEAD TO SCHEDULE INSPECTIONS — ( 904) 247-5826 SEWER CONNECTIONS MUST BE CALLED INTO PUBLIC WORKS FOR INSPECTION CITY OF ATLANTIC BEACH DEPARTMENT OF BUILDING 800 Serminole Road -Atlantic Beach, FL 32233 - Tel: 247-5826 - Fax: 247-5877 PLUMBING PERMIT LO1CA�T1ONjNF0RMATIO. Permit Number: 19225 Address: 1011 BIG PINEKEY Permit Type: PLUMBING ATLANTIC BEACH, FL 32233 Class of Work: REPAIR Township: Range: Book: Proposed Use: SINGLE FAMILY Lot(s): Block: Section: Square Feet: Subdivision: Est. Value: Parcel Number: Improv. Cost: FQRMA� Date Issued: Na e: STEGALL Total Fees: 25.00 Address: 1011 BIG PINE KEY Amount Paid: 25.00 ATLANTIC BEACH, FIL 32233 Date Paid: 11/22/1999 Phone: (904)246-5771 Work esc: REPLACE WATER HEATER 11111ppir KMMQN Eft:&:��� ALLCITY PLUMBING PERMIT 25.00 FINAL NOTICE INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE, AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE CONSTRUCTION LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS" ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. $25.0014 Date: 11/23/99 01 Receipt: 0013829 C BEACH BUI DING DEPT.�­ 2215 A M%�Tl CHECKS 00100003221000 CITY OF ATLANTIC BEACH ;-:7, 800 SEAMOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number 06-00032603 Date 3/24/06 Property Address . . . . . . 1011 BIG PINE KEY Tenant nbr, name . : * * * I INSTALL HEAT PUMP & 1 AHu Application description . . . MECHANICAL ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STEGALL, WILLIAM DONOVAN HEATING & AIR 1011 BIG PINE KEY 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JAX BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . . Permit Fee . . . . 79. 00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 79 . 00 79 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 79. 00 79. 00 . 00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WfM ALL crff OF ATI.ANTIC REACH ORDINANCES AND THE FLORIDA BU"ING CODE& BUILDING OFFICIAL IF, CITY OF ATL MECHANICAL PERMIT APPL Date: iA6 Property Address: /01/ �2 Pine -,t Owner: 57 e Telephone#-. ? Teleph �3 Contractor: one#: V-) z 4ve Contractor Address: yax,#: L.0 b/ contractor Signature: Mhereby agm to In;ccordanw Paula W pan*given in amidwat" for doing&e Work a f;dw above stalman0ft 3414 WQ* des"Ibed with ft allwFwd plans and specificadow whials we a put hamf ad in w=da=with ttwCity of Atlantic Boa ordiasaw ad 44'Wards of good Practice 11sw themilL Type of Ranting Fuel: If other construction,is being dotw on building or si%Us the building permit numbqn M---Electric 0 GaX —Natural ­Qcatral Utility 0 oil 0 Other-Specify NATURE OF WORK MECHANICAL EQUIPMENT TO BE INSTALLED, C) :Heg Space RwC33*d Central Floor 3"PLesideatial 3---Air Conditioning. _Room Q DuctSystem: Material Thiclmess_ 0 Commercial Maximum capacity chn 0 Now Building a �Refteradon a Cooling Tower.Capacity -Apm 0 Existing Building a.,.Fire SpriAldus:Number of Heads Elcvgor.. anlift r 0--o'Replaotment of Existing System, C) ��Gssoliae pumps _(Number) =bar) 0 New lnstallwq� (No system priviously 0 . LPG CTntzinm________.(Numba) Unfimd Pressure Vessel 0 Extension or Add-on to Existing Pystem Boilers y 0 . Other Specif a', -Gas Piping 0 Spec LIST ALL EQUIPMENT AM CONDMONING,REFRIGIESAMON F.QUIPMZNr&CONDENSOWS Appmving, Nuniber Units DacrOon Model 0 manull"Wer Ton's 4, 2�r4v iz 3c, 0 7W4-A�1,5 -4 A, Approving .HyATING FURNACM Bonya%FUWIAczs&AUt HANDLARIS 'Mu's -Agency .-N.umbqr Units Description Model 0 C) 7-7e 7/ tw6" 2040 apscity Type Liquid Serial AWaY4 TANKS Nominal C How Many A Dimensions Contained Manufacum No. Agegg goo Seminole Road 9 Atlantic Duch,Florida 32233-5445 -SUS 9 httt)://www.cf.atlantle-beseh.fl.us Rovised-L104 Phone:(904)247-5800 a Fax: (904)247 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 05-00029954 Date 3/28/05 Property Address . . . . . . 1011 BIG PINE KEY Tenant nbr, name . . . . . . REROOF Application description . . . ROOF Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 4200 Owner Contractor ------------------------ ------------------------ STEGALL, WILLIAM WHITES ROOFING COMPANY INC 1011 BIG PINE KEY 14262 PLEASANT POINT LANE ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32225 (904) 220-5546 ---------------------------------------------------------------- ------------ Permit . . . . . . ROOF PERMIT Additional desc . . Permit Fee . . . . 83 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 4200 Fee summary Charged Paid Credited Due ----- ------------ -- - ------- - --------- --- -- ----- ----- ----- Permit Fee Total 83 . 00 83 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 83 . 00 83 . 00 . 00 . 00 1; APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC REACH ORDINANCES AND THE FLORIDA CITY OF ATLANTIC BEACH Cc: BUILDING / ZONING DEPARTMENT D,,FVrff:::7� (LH* J is� 800 Serninole Road _igp S. Doerr Atlantic Beach,Florida 32233 (904)247-5800 ,Dill (904)247-5845 Fax www.coab.us PLAN REVIEW COMMENTS Permit Application # CA Property Address: L Lcx_pt V_t-c_� k�w Applicant: LO_ti i—re(a_JQQC>-E Project: 'R�i_ Q_,c, F This permit application has been: 10/ Approved F7 Reviewed and the following items need attention: Please re-submit your application when these items have been completed. Reviewed By: Date: Date Contractor Notified: CITY OF ATLANTIC BEACH MAR 2 -A k:�n1r . ROOFING PERMIT APPLICATION CDate: Job Address: L(1 11 43 iri A Owner of Property: ff/// le,j Address: /V 1/ 02 ON7(' kf L; Telephone: JL173 ­72,6, Contractor: Ijb 14A lRoof 1'vl!�) State License Number: Cec 0­5*F(91 7 Contractor's Address: Z g2jec,5ee, 4 1) �. j_f' U, Telephone: Fax: 2AC ScopeofWork: ReWc%.,re S roo�' _-L ru-5 e,_�, Deck Slope: Q11 —Greater than 2:12 Less than 2:12 Valuation of work: o Product Name(Example: Timberline): C?!Ej Manufacturer(Example: GAF): 6—,A ASTM Designation(s) .2) (/402, Required Inspecti ons: eat Ind —0 Signature of Owner: Date: Signature of Contract ate: AS TO'OWNER: Sworn to and subscribed before me this 6 61 day of 20 State of Florida,County of Duval Notary's Signature: my CWMV$$1W COMW <e na known Pr rso c Ily Expm Sop*nbw 22,2= od ed identification Type of identification produced AS TO CONTRACTOR: Sworn to and subscribed before me this day' of 20 State of Florida,County of Duval Notary's Signature: Lit.2 Aixm C, oe/k--� N"Personally known UUMM A w9son Pr( Produced identification W CwwbWm W329W Type of identification produced 800 Seminole Road Atlantic Beach,Florida 32233-5445 Telephone: (904)247-5800 Fax: (904)247-5845 http://www.ci.atlantic-beach.fl.us Pagel Revised 2/21103 NOTICR OF COMMEW'MMENT (PREPARE IN DUPLICATE) Permit No. Tax Folio No. State of County of To whom it may concern: The undersigned hereby Informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following Information Is stated In this NOTICE OF COMMENCEMENT. Legal description of property being improved: A) Piazc ke�j Address of property being improved: 5/2 Q,'ru e�:� (c, 5eeiCk- General description of improvements: e-ytoo e e f 00,C FrI5-�,Jl ne- --,, Owner Address Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Name Address Contractor 1�oe-p,,Y15 Address Z al-e,5 5 e--? ja LA). Phone No. Fax No. 7 Surety(if any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida, other than himself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself,owner designates the following person to receive a copy of the Uenofs Notice as provided in Section 713.06 (2) (b), Florida Statutes, (Fill in at Ownees option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the exi5iration date is one(1)year bw the date of recording unless a different date is specified): 1 iA JI CITY OF ATLANTIC BEACH PERMIT CALCULATION SHEET Address /0 11 t 1,IE— -V—E-q Date zzi f 0,�> Heated Square Footage @ $ per sqft= $ Garage Shed $_-&jq2:_persqft= $ Carport Porch $ per sq ft= $ Deck @$ per sq ft= $ Patio @$ per sq ft= $ TOTAL VALUATION: $ ,42-CO . I $ 35 1--- Total Valuation I A $ 40c"o - v- C)b $ �;to Remaining Value per thousand or portion thereof CONSTRUCTION TYPE: TOTAL BUILDING FEE $ ZONING: + 1/2 Filing Fee $ FLOOD ZONE: )Fireplaces@ $35.00 $ IMPERVIOUS SURFACE: BUILDING PERMIT FEE $ WATER IMPACT FEE $ SEWER IMPACT FEE $ WATER METER/TAP $ CAPITAL IMPROVEMENT$ SEWER TAP $ C( ) RADON .0050 $ SECTION H PAVING ( ) $ HYDRAULIC SHARES $ CROSS CONNECTION $ ST( ) SURCHARGE $ OTHER $ GRAND TOTAL DUE: $ Tratf tratr of Mrrupaur# CITY OF AUS& &Wk- Rai& Oppartinput of Nuilbing This Certificate isstied pursuant to the requirements of Section 109 of the Southern Standard Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances regulating building construction or use, For the following. Use Classification Bldg.Permit No. Group--Type Construction� Fire District. Owner of Building— `01'r —Address__A, 4, 7,� Building Address LA)Cality By: Bu'il—ding Official Date: 0"T IN A CONSPICUOUG PLAGR BUILDING, PLANNING AND ZONING INSPECTION DEPARTMENT CITY OF ATLANTIC BEACH, FLORIDA CERTIFICATE OF OCCUPANCY WORK SHEET Date Requested: 3/2/87 Building Contractor: REYHANI, INC. Building Permit Number: 7778 Address: 1011 BIG PINE KEY Legal Description: LOT 34, SELITA LAKES UNIT I Improvements to the above described property have been completed in accordance with the terms of the permit and is certified to be ready for occupancy as TOWNHOUSE Comments: BEFORE ISSUING CERTIFICATE OF OCCUPANCY THE FOLLOWING MUST BE COMPLETE DEPARTMENT DATE NOTIFIED: DATE APPROVED: BY: Fire Chief 3/2/87 Public Works 3/2/87 Planning Director 3/2/87 3/2/87 Building Inspector 3/2/87 DEPARTMENT OF BUILDING 7779 CITY OF ATLANTIC BEACH,FLORIDA PERMIT NO.- PERMIT TO BUILD THIS PERMIT MUST BE POSTED ON JOB Vogn T 97.60'CKT Date 6/27/86 ig 59t4 Q'7 7779 VOCAC Valuation$ $_ .7 If .50 6/27/$3 This permit not valid until above fee has been paid to City Treasurer,and is I CIO()I subject to revocation for violation Of appliC2ble provisions of law. This is to certify that FAIR PLUMBING has permission to U&I install plumbing Classification Residential —Zone PUD Owned by— RGM Properties Lot 33 & 34 Block S/DSelva Lakes House No. 1007 4 1011 Big Dine Key According to approved plans which are part of this permit NOTICE—ALL CONCRETE FORMS AND FOOTINGS MUST BE IN- SPECTED BEFORE POURING. PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE 4 01 4 1-0 0 Building material, rubbish and debris z-f from this work must not be placed in public space, and must be cleared up and hauled away by either con- tra tor or owner. Kildi g—OR-Cial. FOR OFFICE PERMIT USE ONLY NUMBER DATE CONTRACTOR PLUMBING ELECTRICAL SEWER WATER CITY OF ATLANTIC BEACH APPLICATION FOR PLUMBING PERMIT 249-2395 JOB LOCATION 1007-1011 Big Pine Key PLUMBING CONTRACTOR F. W. FAIR PLUMBING COMPANY LICENSE NUMBERS MP145 State RF0037503 OWNER R G M Properties BUILDING CONTRACTOR R G M Properties TYPE OF BUILDING Duplex 2 SINKS 1 SHOWERS 7 LAVATORY 2 WATER HEATERS 2 BATH TUBS 2 DISHWASHERS URINALS 2 DISPOSALS 5 CLOSETS 2 WASHING MACHINE FLOOR DRAINS OTHER 25 —TOTAL FIXTURE COUNT X�3. 50 + $10. 00 D1111TE 6/ 27 / 11 TOTAL A1,10UNT $97 .50 INSTALLATION OF PLUMBING AND FIXTURES MUST BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE SOUTHERN STANDARD PLUMBING CODE. MAP SHOWING SURVEY OF LOT 34 , SELVA LAKES, AS RECORDED IN PLAT BOOK 41 , PAGES 55 AND 55A OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. .sz Al- '7'0 &I sh t(7 Ale' oel '�e�4noA.l 'jo ';4 /y.A-r/c7".Ac- ov 7, T-cp --.acpw o-oRl" OOA005 IV 7z> 5wv�"v '-7AZ'4c